MOT 2 [DC2] AFT OUT -FLOW VALVE NEG RELIEF VALVE A332 2 SAFETY VALVES ( > 8.85 or < -1 p) A333 3 SAFETY VALVES ( > 8.85 or < -.73 p) OVERPRESS VLV (85psi) Do not use HP GND air with APU bleed FUEL ENGINE Do not use GND AIR with air from packs EMER RAM AIR [DC ESS] LP GND INLETS Hot bleed air Cold air from fan / outside Cold air from packs Mixed conditionned air Cabin recirculated air CPC 1 [DC ESS] PACK 1 CTL [AC1,DC1] AEVC [AC1] CPC 2 [DC2] EIUs [DC BAT] MAN V/S SWITCH AIR SYSTEMS PRESSURIZATION APU Regulated pressure 44 - 52 psi AVIONICS VENT Leak detection Single loop for pylon ducts. Double loop for wing ducts APU duct: A332 single, A333 double loop Temperature control 200°C normal temperature 150°C if wing a/ice OFF and enough for zone controller demand MOT 1 [DC ESS] MAN MOT [DC BAT] MOT 2 [DC2] FWD OUT -FLOW VALVE MOT 1 [DC ESS] MAN MOT [DC BAT] VENT TANKS accept 2% increase of full tanks capacity xfr / refueling / defueling lines feeding lines A332 only A333 only LIMITATIONS RPM min 95% max 107% (auto shut down) running EGT max 650°C start EGT max 1250°C Minimum oil level for start: ADD at APU level indicator Cooling after 3 start attempts: 60min APU FUEL FLOW ~200 kg/hr ENVELOPE START with AC pwr up to 41'100ft (A333 41’450ft) START with EMER ELEC pwr up to 25'000ft BLEED ON 2 packs max 17'500ft, 1 pack max 22'500ft BLEED ON for engine start max 20'000ft APU FUEL IMBALANCE INNER TK Full max 2900kg Half max 4800kg 7500kg max 7500kg OUTER TK Full max 1480kg 2400kg max 1580kg 1730kg max 1730kg FUEL TEMPERATURE JET A1 min -47°C max +60°C JET A min -40°C max +60°C JP-5 min -46°C max +60°C JP-8 min -47°C max +60°C LIMITATIONS Take-off fuel: min 5200kg and WING TK LO LVL not displayed on ECAM F F F F B B1 B2 A332: PW 4168A Thrust 68000lbs = ~30.8t =~27000HP N1: FAN+5 Comp+5 Turb, 100%=3564rpm N2: 11 Comp + 2 Turb, 100%=10145rpm 24 Fuel nozzles + 2 Igniters Warm-up time 5’ before T/O thrust Cool-down time 5' or 1' if required by ops A333: RR RB 211 TRENT Thrust 71100lbs = ~32.2t =~28400HP N1: FAN + 4 Turb, 100%=3300rpm N2: 8 Comp + 1 Turb, 100%=7000rpm N3: 6 Comp + 1 Turb, 100%=10600rpm 24 Fuel nozzles + 2 Igniters Warm-up time 5’ before T/O thrust Cool-down time 1' N1 MODE A/THR & ALPHA FLOOR are lost. RATED P2 and/or P5 lost. Can be selected by pushbutton ENG N1 MODE. UNRATED No protections, ECAM max value are lost BATTERY VENT by a venturi and an overboard vent LAV & GALLEY VENT by an extraction fan and an exhaust through a venturi PACK BAY VENT by a NACA air inlet, a bleed air driventurbofan. Controlled by the AEVC FADECs CH A [AC ESS] CHB [AC2] IGNITION A [AC ESS] A332, A333 on gnd: B ENG1 [AC1] B ENG2 [AC2] A333 inflight: B [AC ESS] APU STARTER [APU BAT, APU TR] Lsby L1 LP HP L2 R L APU F APU FWD XFR PUMP [AC2,DC2] TRIM TK ISOL VLV [DC ESS] APU BLEED VLV to LEFT Bleed duct INLET VLV [DC ESS, HOT] APU LP VLV [DC BAT, HOT] AFT APU PUMP [AC ESS, HOT] AUX FWD XFR VLV [DC ESS] CTR TK INLET VLV [HOT] FWD APU PUMP [AC1] AFT XFR VLVs L [DC1] R [DC2] APU ISOL VLV [HOT] SPLIT VLVs [?] INNER INLET VLVs [DC ESS, HOT] ENG LP VLVs MOT 1[HOT] MOT 2[DC2] REFUEL VLVs [DC BAT, HOT] OUTER INLET VLVs [DC ESS, HOT] OUTER XFR VLVs [DC ESS] X-FEED MOT 1 [DC ESS] MOT 2 [DC2] X-BLEED VLV MANUAL [DC ESS] AUTO [DC2] APU EXT AIR HYD RES CARGO HEAT PACK 1 flow in by-pass mode RESTRICTOR other side CTR TK XFR PUMP R [AC2, DC2] L [AC1, DC1] TRIM PIPE ISOL VLV [DC ESS, HOT] LEFT INNER TK PUMPS L1 [AC2, DC2] L2 [DC ESS, AC ESS] L STBY [AC1, DC1] RIGHT INNER TK PUMPS R1 [AC2, DC2] R2 [DC1, DC ESS, AC ESS] - ess bus only if L2 PMP OFF R STBY [AC1, DC1] CENTER TANK A332 32’625kg TRIM TANK 4’891kg OUTER TANKS 2 X 2’865kg INNER TANKS 2 X 32’970kg ECB [APU BAT DC ESS] CG CONTROL AFT XFR starts if: Gear up, Slats in, Trim TK not full, Inner > 6250kg, above FL255 and CG not on target AFT XFR stops if: CG = target CG - 0.5% or Trim TK full or Inner <6250kg or FWD button pushed or MAN xfr outer-inner or center-inner. FWD XFR starts if: stops if: CG = target CG = target - 0.5% inner = 4000kg inner = 5000kg - 35’ to dest or FL245 (or 75’ if XFR PUMP u/s) - in EMER ELEC INLET ISOL VLV [AC2] OUTLET ISOL VLV [AC2] EXTRACT FAN [AC2] FAN HEATER [AC2] ELECTRICAL SUPPLY ENG loop A [DC ESS], loop B [DC2] ENG BTL 1 squib A [HOT2], squib B [DC2] ENG BTL 2 squib A [HOT1], squib B [DC2] APU loop A [DC ESS], loop B [DC BAT] APU BTL squib A [HOT1] squib B [DC BAT] APU auto extinguish [HOT2] CARGO squib A [HOT1], squib B [DC2] SDCU 1 [DC ESS SHED] SDCU 2 [DC2] VENT CONT [DC2, DC ESS SHED] FIRE PROTECTION & CARGO VENT AFT CARGO COMP BULK BTL 1, 60s discharge BTL 2, 4hrs discharge SMOKE DETECTORS A332:ionization A333:optical FWD CARGO COMP FIRE DETECTORS F FIREX BOTTLES B B1 B2 Cabin air Aft outflow valve OUTLET ISOL VLV [AC2] PACK 1 FLOW CTL VLV [DC ESS] TRIM AIR VLVs HOT AIR X-VLV HOT AIR 1 VLV OVBD EXTRACT VLV EXTRACT FAN [AC1] UNDERFLOOR EXTRACT VLV on gnd engines not running Extract OVRD SMOKE EVAC COCKPIT PANELS EQPMT RACKS FWD CABIN MID CABIN AFT CABIN CABIN AIR CABIN FANs 1 [AC1] 2 [AC2] RECIRC VLVs 1 [AC1] 2 [AC2] HOT AIR 2 VLV to FWD cargo cooling to avionic vent EXTRACT FAN [AC2] Forward Outflow Valve TRIM AIR VLV [DC2, DC ESS SHED] Hot air 1 Cold air from Pack 2 INLET ISOL VLVs [AC2] Cabin air Cabin air Bilge air Bilge air COLD AIR VLV [AC2] to FWD cargo heating - if RAM AIR ON and p<1psi, outflow valves are 50% open (if not in MANUAL) FUEL PUMP UNIT FMU FUEL METERING VLV FILTER (A332) FILTER (A333) FUEL DISTRIBUTION VLV (A332) HP VLV [DC ESS] FAN AIR VLVs ENG 1 [DC1] ENG 2 [DC2] TEMP CTL VLV Main Heat Exchanger BY PASS VLV SLATS 5,6,7 SLAT 4 HP VLVs ENG 1 [DC1] ENG 2 [DC2] A/ICE VLVs ENG 1 [DC1] ENG 2 [DC2] STARTER VLV BLEED VLVs ENG 1 [DC ESS] ENG 2 [DC2] WING A/ICE VLVs [DC ESS SHED] FUEL FLOW IDG OIL (A332) Fuel/Oil Cooler ENG OIL A332:8th HP A333:8th IP A332:15th HP A333:6th HP A332:15th HP A333:3rd HP 24 FUEL INJECTORS PACK 2 FLOW CTL VLV [DC ESS] Primary Heat Exchanger A/ICE VLV PACK 2 Turbofan for pack bay cooling MIXER UNIT CABIN AIR In-flight or Ditching ON PACK CTL channels 1 failed => no effect both failed => temp 1-15°C by anti-ice valve. no ECAM indication. Flow 120% of NORM ZONE CTL channels 1 failed => no effect both failed => Packs deliver 20°C. ECAM ind lost & display PACK REG AIR CYCLE MACHINE failure Pack operates in heat exchanger cooling mode in-flight only HOT AIR VLV failure failed open => no effect 1 vlv failed closed => no effect (X-hot) 2 vlvs failed closed => reg by PACKS TRIM AIR VLV failure 1 failed closed => half this zone lost 1 failed open => half each zone lost !!! NOT FOR OPERATIONAL USE !!! A330 ©Pierre-Michel Gasser , 17.3.2009 PACK 2 CTL [AC2,DC2] ZONE CTL CH1 [DC1] CH2 [DC2] BMC 1 [DC ESS] 2 [DC2] FCMC 1 MAIN [DC ESS SHED] LVL Sensing[DC ESS SHED] FCMC 2 MAIN [HOT] (refuel on BAT) LVL Sensing[DC ESS SHED] XX EPR N1 MODE CLB 92.6% N1 limit only available in RATED mode on at least 1 engine WATER TK MANUAL BACKUP ECAM OUTER TO INNER XFR Each Outer TK cycle its Inner TK between 3500kg and 4000kg until it is empty. The valves then close after 5min. If no AUTO XFR available, manual xfr via refueling pipe and inlet valve possible. CENTER TO INNER XFR A332 The center TK pumps run continously. Each inner TK inlet valve controls the tranfer by cycling its inner TK between FULL and 2000kg below full until it is empty.Then pmps & vlvs close. TOTAL TANKS CAPACITY (den 0.8kg/l) A332: 111’272kg A333: 78’024kg REFUELING Distribution trim TK 2400kg if more than 36.5t FOB A333 only F F F F F F F F A332/A333
Transcript
Page 1: A332/A333 - · PDF fileA332 only A333 only LIMITATIONS ... IDG OIL (A332) Fuel/Oil Cooler ENG OIL A332:8th HP ... !!! NOT FOR OPERATIONAL USE !!! A330 ©Pierre-Michel Gasser , 17.3.2009

MOT 2[DC2]

AFTOUT

-FLOWVALVE

NEGRELIEFVALVE

A3322 SAFETY VALVES( > 8.85 or < -1 ∆p)

A3333 SAFETY VALVES( > 8.85 or < -.73 ∆p)

OVERPRESSVLV (85psi)

Do not use HP GNDair with APU bleed

FUEL

ENGINE

Do not use GND AIRwith air from packsEMER

RAM AIR[DC ESS]

LP GND INLETS

Hot bleed airCold air from fan / outsideCold air from packsMixed conditionned airCabin recirculated air

CPC 1[DC ESS]

PACK 1 CTL[AC1,DC1]

AEVC[AC1]

CPC 2[DC2]

EIUs[DC BAT]

MAN V/SSWITCH

AIR SYSTEMS

PRESSURIZATION

APU

Regulated pressure 44 - 52 psi

AVIONICS VENT

Leak detectionSingle loop for pylon ducts.Double loop for wing ductsAPU duct: A332 single, A333 double loop

Temperature control200°C normal temperature150°C if wing a/ice OFF and enoughfor zone controller demand

MOT 1[DC ESS]

MANMOT

[DC BAT]

MOT 2[DC2]

FWDOUT

-FLOWVALVE

MOT 1[DC ESS]

MANMOT

[DC BAT]

VENT TANKSaccept 2% increaseof full tanks capacity

xfr / refueling / defueling linesfeeding lines

A332 onlyA333 only

LIMITATIONSRPM min 95% max 107% (auto shut down)running EGT max 650°Cstart EGT max 1250°CMinimum oil level for start: ADD at APU level indicatorCooling after 3 start attempts: 60minAPU FUEL FLOW ~200 kg/hr

ENVELOPE START with AC pwr up to 41'100ft (A333 41’450ft)START with EMER ELEC pwr up to 25'000ftBLEED ON 2 packs max 17'500ft, 1 pack max 22'500ftBLEED ON for engine start max 20'000ft

AP

U

FUEL IMBALANCEINNER TK Full max 2900kg Half max 4800kg 7500kg max 7500kgOUTER TK Full max 1480kg 2400kg max 1580kg 1730kg max 1730kg

FUEL TEMPERATUREJET A1 min -47°C max +60°CJET A min -40°C max +60°CJP-5 min -46°C max +60°CJP-8 min -47°C max +60°C

LIMITATIONSTake-off fuel: min 5200kg andWING TK LO LVL not displayed on ECAM

FF

FF B

B1

B2

A332: PW 4168AThrust 68000lbs = ~30.8t =~27000HPN1: FAN+5 Comp+5 Turb, 100%=3564rpmN2: 11 Comp + 2 Turb, 100%=10145rpm24 Fuel nozzles + 2 IgnitersWarm-up time 5’ before T/O thrustCool-down time 5' or 1' if required by ops

A333: RR RB 211 TRENTThrust 71100lbs = ~32.2t =~28400HPN1: FAN + 4 Turb, 100%=3300rpmN2: 8 Comp + 1 Turb, 100%=7000rpmN3: 6 Comp + 1 Turb, 100%=10600rpm24 Fuel nozzles + 2 IgnitersWarm-up time 5’ before T/O thrustCool-down time 1'

N1 MODEA/THR & ALPHA FLOOR are lost.RATEDP2 and/or P5 lost. Can be selected bypushbutton ENG N1 MODE. UNRATEDNo protections, ECAM max value are lost

BATTERY VENTby a venturi and an overboard ventLAV & GALLEY VENTby an extraction fan and an exhaust through a venturiPACK BAY VENTby a NACA air inlet, a bleed airdriventurbofan. Controlled by the AEVC

FADECsCH A [AC ESS]

CHB [AC2]

IGNITIONA [AC ESS]

A332, A333 on gnd:B ENG1 [AC1]B ENG2 [AC2]

A333 inflight:B [AC ESS]

APUSTARTER

[APU BAT, APU TR]

Lsby

L1

LP

HP

L2

RL

APU

F

APU

FWD XFRPUMP

[AC2,DC2]

TRIM TKISOL VLV[DC ESS]

APUBLEEDVLV

to LEFTBleed duct

INLET VLV[DC ESS, HOT]

APULP VLV

[DC BAT, HOT]

AFT APU PUMP[AC ESS, HOT]

AUX FWDXFR VLV[DC ESS]

CTR TKINLET VLV[HOT]

FWD APUPUMP[AC1]

AFT XFR VLVsL [DC1]R [DC2]

APUISOLVLV[HOT]

SPLITVLVs

[?]INNERINLETVLVs

[DC ESS, HOT]

ENGLP VLVsMOT 1[HOT]MOT 2[DC2]

REFUELVLVs[DC BAT, HOT]

OUTERINLETVLVs

[DC ESS, HOT]

OUTERXFR

VLVs[DC ESS]

X-FEEDMOT 1 [DC ESS]MOT 2 [DC2]

X-BLEED VLVMANUAL [DC ESS]

AUTO [DC2]

APUEXT AIR

HY

D R

ES

CARGOHEAT

PACK 1flow in by-passmode

RESTRICTOR

other side

CTR TKXFR PUMPR [AC2, DC2]L [AC1, DC1]

TRIM PIPEISOL VLV[DC ESS, HOT]

LEFT INNER TKPUMPS

L1 [AC2, DC2]L2 [DC ESS, AC ESS]

L STBY [AC1, DC1]

RIGHT INNER TKPUMPSR1 [AC2, DC2]R2 [DC1, DC ESS, AC ESS] - ess bus only if L2 PMP OFFR STBY [AC1, DC1]

CENTER TANK A332

32’625kg

TRIM TANK4’891kg

OUTER TANKS

2 X 2’865kg

INNER TANKS

2 X 32’970kg

ECB[APU BATDC ESS]

CG CONTROLAFT XFR starts if:Gear up, Slats in, Trim TK not full, Inner > 6250kg, above FL255 and CG not on targetAFT XFR stops if:CG = target CG - 0.5% or Trim TK full or Inner <6250kg or FWD button pushed or MAN xfr outer-inner or center-inner.FWD XFR starts if: stops if:CG = target CG = target - 0.5%inner = 4000kg inner = 5000kg- 35’ to dest or FL245 (or 75’ if XFR PUMP u/s)- in EMER ELEC

INLETISOL VLV[AC2]

OUTLETISOL VLV[AC2]

EXTRACTFAN[AC2]

FANHEATER[AC2]

ELECTRICAL SUPPLYENG loop A [DC ESS], loop B [DC2]ENG BTL 1 squib A [HOT2], squib B [DC2]ENG BTL 2 squib A [HOT1], squib B [DC2]APU loop A [DC ESS], loop B [DC BAT] APU BTL squib A [HOT1] squib B [DC BAT]APU auto extinguish [HOT2]CARGO squib A [HOT1], squib B [DC2]

SDCU 1[DC ESS SHED]

SDCU 2[DC2]

VENT CONT[DC2, DC ESS SHED]

FIRE PROTECTION& CARGO VENT

AFTCARGOCOMP

BULK

BTL 1, 60s discharge

BTL 2, 4hrs discharge

SMOKE DETECTORSA332:ionization A333:optical

FWDCARGOCOMP

FIRE DETECTORSF

FIREX BOTTLESB

B1

B2

Cabin air

Aft outflowvalve

OUTLETISOL VLV[AC2]

PACK 1FLOWCTL VLV[DC ESS]

TRIMAIR VLVs

HOT AIRX-VLV

HOT AIR 1VLV

OVBDEXTRACTVLV

EXTRACT FAN [AC1]

UNDERFLOOREXTRACTVLV

on gnd enginesnot running

Extract OVRDSMOKE EVAC

COCKPITPANELS

EQPMTRACKS

FWD CABIN MID CABIN AFT CABINCABIN

AIR

CABINFANs1 [AC1]2 [AC2]

RECIRCVLVs1 [AC1]2 [AC2]

HOT AIR 2VLV

to FWDcargo cooling

to avionicvent

EXTRACTFAN[AC2] Forward

OutflowValve

TRIMAIR VLV[DC2, DC ESS SHED]

Hot air 1Cold air from Pack 2

INLET ISOL VLVs [AC2]

Cabinair

Cabinair

Bilge air

Bilge air

COLDAIR VLV[AC2]

to FWDcargoheating

- if RAM AIR ON and ∆p<1psi, outflow valvesare 50% open(if not in MANUAL)

FUELPUMPUNIT

FMU

FUEL METERING VLVFILTER (A332)

FILTER (A333)

FUEL DISTRIBUTIONVLV (A332)

HP VLV [DC ESS]

FAN AIRVLVsENG 1 [DC1]ENG 2 [DC2]

TEMPCTL VLV

Main HeatExchanger

BY PASSVLV

SLATS5,6,7

SLAT 4

HP VLVsENG 1 [DC1]ENG 2 [DC2]

A/ICE VLVsENG 1 [DC1]ENG 2 [DC2]

STARTERVLV

BLEED VLVsENG 1 [DC ESS]

ENG 2 [DC2]

WING A/ICE VLVs[DC ESS SHED]

FUEL FLOW

IDG OIL (A332)

Fuel/Oil Cooler

ENG OIL

A332:8th HPA333:8th IP

A332:15th HPA333:6th HP

A332:15th HPA333:3rd HP

24 FUEL INJECTORS

PACK 2FLOWCTL VLV[DC ESS]

Primary HeatExchanger

A/ICEVLV

PACK 2

Turbofan for packbay cooling

MIXER UNIT

CABINAIR

In-flight orDitching ON

PACK CTL channels1 failed => no effectboth failed => temp 1-15°C by anti-ice valve. no ECAM indication. Flow 120% of NORM ZONE CTL channels1 failed => no effectboth failed => Packs deliver 20°C. ECAM ind lost & display PACK REG

AIR CYCLE MACHINE failurePack operates in heat exchanger cooling mode in-flight onlyHOT AIR VLV failurefailed open => no effect1 vlv failed closed => no effect (X-hot)2 vlvs failed closed => reg by PACKSTRIM AIR VLV failure1 failed closed => half this zone lost1 failed open => half each zone lost

!!! NOT FOR OPERATIONAL USE !!! A330 ©Pierre-Michel Gasser , 17.3.2009

PACK 2 CTL[AC2,DC2]

ZONE CTLCH1 [DC1]CH2 [DC2]

BMC1 [DC ESS]

2 [DC2]

FCMC 1MAIN [DC ESS SHED]

LVL Sensing[DC ESS SHED]

FCMC 2MAIN [HOT] (refuel on BAT)LVL Sensing[DC ESS SHED]

XX

EPR N1 MODECLB92.6%

N1 limitonly availablein RATED modeon at least1 engine

WA

TE

R T

K

MANUALBACKUP

ECAM

OUTER TO INNER XFREach Outer TK cycle its Inner TK between 3500kg and 4000kg until it is empty. The valves then close after 5min. If no AUTO XFR available, manual xfr via refueling pipe and inlet valve possible.

CENTER TO INNER XFR A332The center TK pumps run continously.Each inner TK inlet valve controls the tranfer by cycling its inner TK between FULL and 2000kgbelow full until it is empty.Then pmps & vlvs close.

TOTAL TANKS CAPACITY (den 0.8kg/l)A332: 111’272kgA333: 78’024kg

REFUELINGDistribution trim TK 2400kg if more than 36.5t FOB

A333only

FF

FF

FF

FF

A332/A333

Recommended