44
12-31-14 EXPIRES R E G I S T E R E D P A N I S S E F O R L O I G N E N E E R J u l y 9 9 9 1 , 3 44775 OREGON 1 G R A N T R . A R T H E M E R P S S S S S S S S S S ABBREVIATIONS NOTE NL NIGHT LIGHT CIRCUIT PUBLIC ADDRESS TRANSFER SWITCH XFSW TRANSFORMER XFMR WEATHER PROOF WP WATTS W VAPOR PROOF VP VOLT AMPERES VA VOLTAGE V UNINTERRUPTABLE POWER SUPPLY UPS UNDERGROUND UG TYPICAL TYP TELEVISION TV TELEPHONE TERMINAL CABINET TTC TELEPHONE TERMINAL BOARD TTB TAMPERPROOF TP TIME DELAY TD SWITCH SW SOLENOID VALVE SV STARTER STR SUB-DISTRIBUTION PANEL SDP POWER PWR POLYVINYL CHLORIDE CONDUIT PVC PANELBOARD PNL POWER FACTOR PF PHOTO ELECTRIC CELL PE PA NOT IN CONTRACT NIC MANUAL TRANSFER SWITCH MTS MERCURY VAPOR MV MAIN LUGS ONLY MLO METAL HALIDE MH MECHANICAL MECH MAIN DISTRIBUTION PANEL MDP MOTOR CONTROL CENTER MCC MAIN CIRCUIT BREAKER MCB MINIMUM CIRCUIT AMPS MCA MASTER ANTENNA TELEVISION MATV LOW VOLTAGE LV LIGHTING LTG LIGHTNING ARRESTOR LA KILOVOLT AMPS REACTIVE KVAR KILOVOLT AMP KVA KILOVOLT KV KILOWATT HOUR KWH KILOWATT KW JUNCTION BOX JB INCANDESCENT INC ISOLATED GROUND IG HERTZ HZ HIGH VOLTAGE HV HIGH PRESSURE SODIUM HPS HORSEPOWER HP GROUND GRD GALVANIZED RIGID CONDUIT GRC GROUND FAULT CIRCUIT INTERRUPTER GFCI GROUND FAULT INTERRUPTER GFI GROUND FAULT PROTECTION GFP INSTALLED BY OWNER FURNISHED BY OWNER FOIO INSTALLED BY CONTRACTOR FURNISHED BY OWNER FOIC INSTALLED BY CONTRACTOR FURNISHED BY CONTRACTOR FCIC FLUORESCENT FLUOR FULL LOAD AMPS FLA FIRE ALARM FA ELECTRIC WATER COOLER EWC EMERGENCY POWER OFF EPO EXPLOSION PROOF EP ELECTRIC METALLIC TUBING EMT EMERGENCY EMERG DOWN DN COPPER CU CURRENT TRANSFORMER CT CEILING CLG CIRCUIT CKT CLOSED CIRCUIT TELEVISION CCTV CONDUIT C CIRCUIT BREAKER CB AUTOMATIC TRANSFER SWITCH ATS ARCHITECT / ARCHITECTURAL ARCH ALUMINUM AL AMPERE (AMP) A ABOVE FINISHED FLOOR AFF THIS IS A STANDARD LEGEND SHEET, THEREFORE, SOME SYMBOLS MAY APPEAR ON THIS SHEET THAT DO NOT APPEAR ON THE DRAWINGS. DESIGNATION SYMBOLS 123 1 X E NEW, CONNECT TO EQUIPMENT DESIGNATOR SEE SCHEDULE. NOTE EXISTING TO BE RELOCATED, FUTURE EXISTING TO REMAIN, EXISTING TO BE REMOVED C N --- F R EQUIPMENT LIGHTING NOTES: GENERAL NOTES: FINISHED FLOOR CEILING MOUNTING HEIGHTS FIRE 6" MIN 12" MIN 6" 18" 36" 40" 48" 90" 96" 1 OCCUPANCY SENSOR FIRE ALARM STROBES FIRE ALARM PULL STATION LIGHT SWITCH CARD READER WALL PHONE ABOVE COUNTER RECEPTACLE RECEPTACLE DATA OUTLET 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1. LOCATE ALL FIRE ALARM DEVICES PER CODE. LOCATE ALL ACCESSIBLE SWITCHES PER ADA GUIDELINES. FIELD COORDINATE ALL ABOVE COUNTER DEVICES WITH MILLWORK CONTRACTOR. IF APPLICABLE, TELCOM CONSULTANTS DRAWINGS TAKE PRECEDENCE OVER THIS DETAIL FOR TELCOM DEVICES. 2. 3. 4. XXX XX X XXX ONE-LINE CIRCUIT BREAKER SWITCH, FUSED SWITCH AUTOMATIC SWITCH METER PANEL FEEDER CALLOUT FAULT CURRENT CALLOUT BUSS G GENERATOR M POWER F F F F K E T A I M E C P H P P F F S S F TV V F F FS TS SIGNAL FIRE ALARM TELECOMMUNICATIONS SECURITY SECURITY ELECTRONIC SENSOR CARD KEY READER STATION MANUAL EMERGENCY SECURITY STATION FIRE ALARM: VISUAL WALL OUTLET: MICROPHONE, INTERCOM, AUDIO JACK THERMOSTAT FIRE ALARM SPEAKER: WALL, CEILING FIRE ALARM: HORN; HORN W/VISUAL; CEILING MOUNTED FIRE ALARM: BELL; BELL W/VISUAL WALL OUTLET: VOLUME CONTROL WALL OUTLET: TELEPHONE, EMERGENCY TELEPHONE, DATA MASTER ANTENNA TV OUTLET SYSTEM CLOCK: WALL, CEILING ELECTRIC DOOR LOCK, CONTACT MAGNETIC DOOR HOLDER, CLOSER SPEAKER: WALL, CEILING DUCT DETECTOR, TYPE AS NOTED DETECTOR: IONIZATION, HEAT, PHOTOELECTRIC SPRINKLER SYSTEM SWITCH: FLOW, TAMPER MANUAL FIRE ALARM STATION CCTV CAMERA FIREMANS PHONE JACK WALL OUTLET: COMBINATION TELEPHONE/DATA D,U,R CABLE/JACK QUANTITY DETECTOR: BEAM ELECTRICAL EQUIPMENT (GENERIC) TRANSFORMER CABINET: SURFACE, RECESSED PANELBOARD: SURFACE, RECESSED GROUND PAD GROUND ROD, IN TEST WELL DISCONNECT SWITCH PLYWOOD BACKBOARD ATS SWITCH CONDUIT ROUTING WITH PULL BOX OS PE OS PE J LV P M K 3 4 S A WALL SWITCH: KEY LOCK, MOMENTARY WALL SWITCH: 3 WAY, 4 WAY DESIGNATES LUMINAIRE TYPE (SEE LUMINAIRE SCHEDULE) BOLLARD FLUORESCENT LUMINAIRE: BARE LAMP WALL LUMINAIRE: SURFACE, RECESSED POLE LIGHT: LUMINAIRES AS SHOWN TRACK WITH HEADS LOCATED WALL WASHER: SURFACE, RECESSED PHOTOELECTRIC CELL: WALL MOUNTED, CEILING MOUNTED WALL SWITCH: TIMER, MANUAL DIMMER WALL SWITCH: LOW VOLTAGE, PILOT WALL SWITCH: 1 POLE, SENTRY SWITCH EMERGENCY BATTERY LIGHT: HEADS AS SHOWN EXIT LIGHT: CEILING, WALL (ARROWS AS SHOWN) DESIGNATES LIGHT ON EMERGENCY CIRCUIT FLUORESCENT LUMINAIRE: SURFACE, RECESSED FLUORESCENT LUMINAIRE: WALL MOUNTED CEILING LUMINAIRE: SURFACE, RECESSED D T CEILING LUMINAIRE: PENDANT MOUNTED PENDANT LUMINAIRE: SMALL PROFILE, WIDE PROFILE NL DESIGNATES NIGHT LIGHT CIRCUIT OCCUPANCY SENSOR: CEILING OR WALL MOUNTED REFERENCE FLOOR PLANS FOR TYPE OF SENSOR UNI-STRUT LIGHTING ASSEMBLY S C J OL MOTOR STARTER: MANUAL, MAGNETIC, COMBINATION WIRING CONCEALED IN CEILING OR WALL WIRING CONCEALED IN FLOOR OR UNDERGROUND SURFACE OUTLET STRIP: DIMENSION AS SHOWN WALL RECEPTACLE: EMERGENCY, QUADPLEX WALL RECEPTACLE: SINGLE, DUPLEX PUSH BUTTON STATION JUNCTION BOX DENOTES RECEPTACLE ABOVE COUNTER SPECIAL PURPOSE OUTLET AS NOTED, EMERGENCY CEILING RECEPTACLE: DUPLEX, QUADPLEX FLUSH IN-FLOOR OUTLET: DUPLEX, QUAD MOTOR CONNECTION CONTACTOR, SOLENOID INDICATES INSULATED GREEN GROUND WIRE HOME RUN DESTINATION SHOWN CONDUIT ELL: UP, DN. WALL RECEPTACLE: ISOLATED GROUND FIRE RATED FLOOR POKE-THRU J I UL UL 924 DEVICE R LIGHTING RELAY PP POWER PACK B BALLAST (DIMMING) EMERGENCY EM KEYBOARD/DISPLAY UNIT KDU FIRE ALARM CONTROL PANEL FACP BOTTOM OF CABLE TRAY BOCT F C CABLE TRAY 45" REVISIONS: CHECKED: P R O J E C T # : I S S U E D A T E : D R A W N : PRINTED ON: 2014 PIVOT ARCHITECTURE FROM FILE: C 9/12/2014 3:25:44 PM C:\Revit Local Files\13-1532_HES MEP14\13-1532_HES MEP14_stacy.hansen.rvt SYMBOLS, LEGENDS AND ABBREVIATIONS - ELECTRICAL EUGENE SCHOOL DISTRICT BUILDING AND SITE CONSTRUCTION DOCUMENTS HOWARD ELEMENTARY SCHOOL 1 3 3 6 0 9 / 2 3 / 2 0 1 4 E001 AMT SJT 700 HOWARD AVE, EUGENE, OREGON 97404
Transcript
  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    S S

    SS

    S S

    SS

    SS

    ABBREVIATIONS

    NOTE

    NL NIGHT LIGHT CIRCUIT

    PUBLIC ADDRESS

    TRANSFER SWITCHXFSW

    TRANSFORMERXFMR

    WEATHER PROOFWP

    WATTSW

    VAPOR PROOFVP

    VOLT AMPERESVA

    VOLTAGEV

    UNINTERRUPTABLE POWER SUPPLYUPS

    UNDERGROUNDUG

    TYPICALTYP

    TELEVISIONTV

    TELEPHONE TERMINAL CABINETTTC

    TELEPHONE TERMINAL BOARDTTB

    TAMPERPROOFTP

    TIME DELAYTD

    SWITCHSW

    SOLENOID VALVESV

    STARTERSTR

    SUB-DISTRIBUTION PANELSDP

    POWERPWR

    POLYVINYL CHLORIDE CONDUITPVC

    PANELBOARDPNL

    POWER FACTORPF

    PHOTO ELECTRIC CELLPE

    PA

    NOT IN CONTRACTNIC

    MANUAL TRANSFER SWITCHMTS

    MERCURY VAPORMV

    MAIN LUGS ONLYMLO

    METAL HALIDEMH

    MECHANICALMECH

    MAIN DISTRIBUTION PANELMDP

    MOTOR CONTROL CENTERMCC

    MAIN CIRCUIT BREAKERMCB

    MINIMUM CIRCUIT AMPSMCA

    MASTER ANTENNA TELEVISIONMATV

    LOW VOLTAGELV

    LIGHTINGLTG

    LIGHTNING ARRESTORLA

    KILOVOLT AMPS REACTIVEKVAR

    KILOVOLT AMPKVA

    KILOVOLTKV

    KILOWATT HOURKWH

    KILOWATTKW

    JUNCTION BOXJB

    INCANDESCENTINC

    ISOLATED GROUNDIG

    HERTZHZ

    HIGH VOLTAGEHV

    HIGH PRESSURE SODIUMHPS

    HORSEPOWERHP

    GROUNDGRD

    GALVANIZED RIGID CONDUITGRC

    GROUND FAULT CIRCUIT INTERRUPTERGFCI

    GROUND FAULT INTERRUPTERGFI

    GROUND FAULT PROTECTIONGFP

    INSTALLED BY OWNER

    FURNISHED BY OWNERFOIO

    INSTALLED BY CONTRACTOR

    FURNISHED BY OWNERFOIC

    INSTALLED BY CONTRACTOR

    FURNISHED BY CONTRACTORFCIC

    FLUORESCENTFLUOR

    FULL LOAD AMPSFLA

    FIRE ALARMFA

    ELECTRIC WATER COOLEREWC

    EMERGENCY POWER OFFEPO

    EXPLOSION PROOFEP

    ELECTRIC METALLIC TUBINGEMT

    EMERGENCYEMERG

    DOWNDN

    COPPERCU

    CURRENT TRANSFORMERCT

    CEILINGCLG

    CIRCUITCKT

    CLOSED CIRCUIT TELEVISIONCCTV

    CONDUITC

    CIRCUIT BREAKERCB

    AUTOMATIC TRANSFER SWITCHATS

    ARCHITECT / ARCHITECTURALARCH

    ALUMINUMAL

    AMPERE (AMP)A

    ABOVE FINISHED FLOORAFF

    THIS IS A STANDARD LEGEND SHEET, THEREFORE, SOME SYMBOLS MAY

    APPEAR ON THIS SHEET THAT DO NOT APPEAR ON THE DRAWINGS.

    DESIGNATION SYMBOLS

    123

    1

    XE

    NEW, CONNECT TO

    EQUIPMENT DESIGNATOR SEE SCHEDULE.

    NOTE

    EXISTING TO BE RELOCATED, FUTURE

    EXISTING TO REMAIN, EXISTING TO BE REMOVED

    CN

    ---

    FR

    EQUIPMENT LIGHTING

    NOTES:

    GENERAL NOTES:

    FINISHED FLOOR

    CEILING

    MOUNTING HEIGHTS

    FIRE

    6"

    MIN 12"MIN 6"

    18"

    36"

    40"

    48"

    90"

    96"

    1 OCCUPANCY SENSOR

    FIRE ALARM STROBES

    FIRE ALARM PULL STATION

    LIGHT SWITCH

    CARD READER

    WALL PHONE

    ABOVE COUNTER RECEPTACLE

    RECEPTACLE

    DATA OUTLET

    2

    3

    4

    5

    6

    7

    8

    9

    1

    2

    34

    5

    6 7

    8 9

    1. LOCATE ALL FIRE ALARM DEVICES PER CODE.

    LOCATE ALL ACCESSIBLE SWITCHES PER ADA GUIDELINES.

    FIELD COORDINATE ALL ABOVE COUNTER DEVICES WITH

    MILLWORK CONTRACTOR.

    IF APPLICABLE, TELCOM CONSULTANTS DRAWINGS TAKE

    PRECEDENCE OVER THIS DETAIL FOR TELCOM DEVICES.

    2.

    3.

    4.

    XXXXX

    X

    XXX

    ONE-LINE

    CIRCUIT BREAKER

    SWITCH, FUSED SWITCH

    AUTOMATIC SWITCH

    METER

    PANEL

    FEEDER CALLOUT

    FAULT CURRENT CALLOUT

    BUSS

    G GENERATOR

    M

    POWER

    FF

    FF

    K

    E

    T

    AIM

    E

    C

    PH

    PP

    FF

    SS

    F

    TV

    V

    F

    F

    FS TS

    SIGNAL

    FIRE ALARM

    TELECOMMUNICATIONS

    SECURITY

    SECURITY ELECTRONIC SENSOR

    CARD KEY READER STATION

    MANUAL EMERGENCY SECURITY STATION

    FIRE ALARM: VISUAL

    WALL OUTLET: MICROPHONE, INTERCOM, AUDIO JACK

    THERMOSTAT

    FIRE ALARM SPEAKER: WALL, CEILING

    FIRE ALARM: HORN; HORN W/VISUAL; CEILING MOUNTED

    FIRE ALARM: BELL; BELL W/VISUAL

    WALL OUTLET: VOLUME CONTROL

    WALL OUTLET: TELEPHONE, EMERGENCY TELEPHONE, DATA

    MASTER ANTENNA TV OUTLET

    SYSTEM CLOCK: WALL, CEILING

    ELECTRIC DOOR LOCK, CONTACT

    MAGNETIC DOOR HOLDER, CLOSER

    SPEAKER: WALL, CEILING

    DUCT DETECTOR, TYPE AS NOTED

    DETECTOR: IONIZATION, HEAT, PHOTOELECTRIC

    SPRINKLER SYSTEM SWITCH: FLOW, TAMPER

    MANUAL FIRE ALARM STATION

    CCTV CAMERA

    FIREMANS PHONE JACK

    WALL OUTLET: COMBINATION TELEPHONE/DATAD,U,R

    CABLE/JACK QUANTITY

    DETECTOR: BEAM

    ELECTRICAL EQUIPMENT (GENERIC)

    TRANSFORMER

    CABINET: SURFACE, RECESSED

    PANELBOARD: SURFACE, RECESSED

    GROUND PAD

    GROUND ROD, IN TEST WELL

    DISCONNECT SWITCH

    PLYWOOD BACKBOARD

    ATS SWITCH

    CONDUIT ROUTING WITH PULL BOX

    OS

    PE

    OS

    PE

    J

    LV P

    MK

    3 4

    S

    A

    WALL SWITCH: KEY LOCK, MOMENTARY

    WALL SWITCH: 3 WAY, 4 WAY

    DESIGNATES LUMINAIRE TYPE (SEE LUMINAIRE SCHEDULE)

    BOLLARD

    FLUORESCENT LUMINAIRE: BARE LAMP

    WALL LUMINAIRE: SURFACE, RECESSED

    POLE LIGHT: LUMINAIRES AS SHOWN

    TRACK WITH HEADS LOCATED

    WALL WASHER: SURFACE, RECESSED

    PHOTOELECTRIC CELL: WALL MOUNTED, CEILING MOUNTED

    WALL SWITCH: TIMER, MANUAL DIMMER

    WALL SWITCH: LOW VOLTAGE, PILOT

    WALL SWITCH: 1 POLE, SENTRY SWITCH

    EMERGENCY BATTERY LIGHT: HEADS AS SHOWN

    EXIT LIGHT: CEILING, WALL (ARROWS AS SHOWN)

    DESIGNATES LIGHT ON EMERGENCY CIRCUIT

    FLUORESCENT LUMINAIRE: SURFACE, RECESSED

    FLUORESCENT LUMINAIRE: WALL MOUNTED

    CEILING LUMINAIRE: SURFACE, RECESSED

    DT

    CEILING LUMINAIRE: PENDANT MOUNTED

    PENDANT LUMINAIRE: SMALL PROFILE, WIDE PROFILE

    NL DESIGNATES NIGHT LIGHT CIRCUIT

    OCCUPANCY SENSOR: CEILING OR WALL MOUNTED

    REFERENCE FLOOR PLANS FOR TYPE OF SENSOR

    UNI-STRUT LIGHTING ASSEMBLY

    SC

    J

    OL MOTOR STARTER: MANUAL, MAGNETIC, COMBINATION

    WIRING CONCEALED IN CEILING OR WALL

    WIRING CONCEALED IN FLOOR OR UNDERGROUND

    SURFACE OUTLET STRIP: DIMENSION AS SHOWN

    WALL RECEPTACLE: EMERGENCY, QUADPLEX

    WALL RECEPTACLE: SINGLE, DUPLEX

    PUSH BUTTON STATION

    JUNCTION BOX

    DENOTES RECEPTACLE ABOVE COUNTER

    SPECIAL PURPOSE OUTLET AS NOTED, EMERGENCY

    CEILING RECEPTACLE: DUPLEX, QUADPLEX

    FLUSH IN-FLOOR OUTLET: DUPLEX, QUAD

    MOTOR CONNECTION

    CONTACTOR, SOLENOID

    INDICATES INSULATED GREEN GROUND WIRE

    HOME RUN DESTINATION SHOWN

    CONDUIT ELL: UP, DN.

    WALL RECEPTACLE: ISOLATED GROUND

    FIRE RATED FLOOR POKE-THRU

    J

    I

    UL UL 924 DEVICE

    R LIGHTING RELAY

    PP POWER PACK

    B BALLAST (DIMMING)

    EMERGENCYEM

    KEYBOARD/DISPLAY UNITKDU

    FIRE ALARM CONTROL PANELFACP

    BOTTOM OF CABLE TRAYBOCT

    FC

    CABLE TRAY

    45"

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :25:4

    4 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    SY

    MB

    OLS

    , LE

    GE

    ND

    S A

    ND

    AB

    BR

    EV

    IAT

    ION

    S -

    ELE

    CT

    RIC

    AL

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E001

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    Tag Description Size Watts Lamp(s) Ballast Voltage Product Mounting Finish Notes

    L1-4SUSPENDED LED LINEARDIRECT/INDIRECT

    NOMINAL 8INCH WIDE X2 INCH DEEPX FOUR FEET

    LONG

    41

    LED, 4000K4500

    DELIVEREDLUMENS PERFOUR FOOT

    SECTION

    0-10 DIMMINGELECTRONIC

    UNIVERSALVOLTAGE

    CORELITE JAULUM SERIES,PEERLESS STAPLE SERIES, LEDALITE

    SYNC SERIES, AXISSURROUNDLIGHT SERIES

    SUSPENDEDAIRCRAFT CABLE

    STANDARD ASSELECTED BYARCHITECT

    NOMINAL DISTRIBUTION IS TO BE70% INDIRECT 30 % DIRECT.

    L1-8SUSPENDED LED LINEARDIRECT/INDIRECT

    NOMINAL 8INCH WIDE X2 INCH DEEPX EIGHT FEET

    LONG

    82

    LED, 4000K4500

    DELIVEREDLUMENS PERFOUR FOOT

    SECTION

    0-10 DIMMINGELECTRONIC

    UNIVERSALVOLTAGE

    CORELITE JAULUM SERIES,PEERLESS STAPLE SERIES, LEDALITE

    SYNC SERIES, AXISSURROUNDLIGHT SERIES

    SUSPENDEDAIRCRAFT CABLE

    STANDARD ASSELECTED BYARCHITECT

    NOMINAL DISTRIBUTION IS TO BE70% INDIRECT 30 % DIRECT.

    L2 RECESSED LENSED LED4 INCH X 4

    INCH X 4 FEETLONG

    32

    LED 4000 K3000 LUMENS

    PER FOURFOOT

    SECTION

    0-10 DIMMINGELECTRONIC

    UNIVERSALVOLTAGE

    AXIS BEAM SERIES, NULITE RT4SERIES , NEO RAY STRAIGHT AND

    NARROW SERIESCEILING RECESSED

    STANDARD ASSELECTED BYARCHITECT

    FLANGELESS INSTALLATION

    L2ASAME AS TYPE L2 EXCEPT VERTICALWALL MOUNT - FLANGELESS

    4 INCH X 4INCH X 4 FEET

    LONG32

    LED 4000 K3000 LUMENS

    PER FOURFOOT

    SECTION

    0-10 DIMMINGELECTRONIC

    UNIVERSALVOLTAGE

    AXIS BEAM SERIES, NULITE RT4SERIES , NEORAY STRAIGHT AND

    NARROW SERIESCEILING RECESSED

    STANDARD ASSELECTED BYARCHITECT

    FLANGELESS VERTICAL WALLMOUNT INSTALLATION

    L3A RECESSED LED CIRCULAR CLOUD2 FOOT

    DIAMETER29 1400 LUMENS

    0-10 DIMMINGELECTRONIC

    UNIVERSALVOLTAGE

    PRUDENTIAL P9000 SERIES, MARKLIGHTING MAGELLAN SERIES

    CEILING RECESSEDSTANDARD ASSELECTED BYARCHITECT

    L3B RECESSED LED CIRCULAR CLOUD4 FOOT

    DIAMETER89 5500 LUMENS

    0-10 DIMMINGELECTRONIC

    UNIVERSALVOLTAGE

    PRUDENTIAL P9000 SERIES, MARKLIGHTING MAGELLAN SERIES

    CEILING RECESSEDSTANDARD ASSELECTED BYARCHITECT

    L4 RECESSED LED 2X22X2 FEETSQUARE

    37LED, 3700LUMENS

    0-10 DIMMINGELECTRONIC

    UNIVERSALVOLTAGE

    LITHONIA 2ALL SERIES, CORELITEENCOUNTER SERIES LEDALITE

    PURE FX SERIES, AXIS DAYCEILING RECESSED

    STANDARD ASSELECTED BYARCHITECT

    L4ARECESSED LED 2X2 FOOD SERVICERATED

    2X2 FEETSQUARE

    45LED, 4400LUMENS

    0-10 DIMMINGELECTRONIC

    UNIVERSALVOLTAGE

    KURTZON FP SERIES CEILING RECESSEDSTANDARD ASSELECTED BYARCHITECT

    FOOD SERVICE RATED

    L5 RECESSED LED DOWNLIGHT6 INCHROUND

    APERTURE28 1800 LUMENS

    0-10 DIMMINGELECTRONIC

    UNIVERSALVOLTAGE

    GOTHAM EVO SERIES PORTFOLIOLD6A SERIES, INDY

    CEILING RECESSEDCLEAR ALZAKREFLECTOR

    L6 SURFACE MOUNTED LINEAR LED

    NOMINAL 8INCH WIDE X

    FOUR FEETLONG

    40 4000 LUMENS 0-10 DIMMINGELECTRONIC

    UNIVERSALVOLTAGE

    LITHONIA STL SERIES, OR PRE-BIDAPPROVED

    SURFACE CEILINGSTANDARD ASSELECTED BYARCHITECT

    L7SURFACE OR SUSPENDED LEDLENSED STRIP

    NOMINAL 3INCH WIDE X4 FEET LONG

    32 1800 LUMENS 0-10 DIMMINGELECTRONIC

    UNIVERSALVOLTAGE

    LITHONIA ZL2N SERIES, METALUXSNLED SERIES

    SURFACE CEILING,OR CHAIN HUNG

    STANDARD ASSELECTED BYARCHITECT

    L8 LINEAR LED HIGHBAY

    NOMINAL 4INCH WIDE X

    16 FOOTROW AND 4FOOT LONGINDIVIDUAL

    47 PERFOURFEET

    3500 LUMENSPER FOUR FEET

    0-10 DIMMINGELECTRONIC

    UNIVERSALVOLTAGE

    LITHONIA PTSNL SERIESSURFACE TO

    BOTTOM CHORDOF TRUSS

    STANDARD ASSELECTED BYARCHITECT

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :25:4

    6 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    LU

    MIN

    AIR

    E S

    CH

    ED

    ULE

    1 O

    F 2

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E002

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    Tag Description Size Watts Lamp(s) Ballast Voltage Product Mounting Finish Notes

    L10 LED CYLINDER

    16 HIGH X 8INCH

    DIAMETERWITH 6 INCH

    APERTURE

    996000 LUMEN60 DEGREE

    0-10 DIMMINGELECTRONIC

    UNIVERSALVOLTAGE

    GOTHAM INCITO, PORTFOLIOLCR8A,.

    SURFACESTANDARD ASSELECTED BYARCHITECT

    L10A LED CYLINDER

    16 HIGH X 8INCH

    DIAMETERWITH 6 INCH

    APERTURE

    996000 LUMEN45 DEGREE

    0-10 DIMMINGELECTRONIC

    UNIVERSALVOLTAGE

    GOTHAM INCITO, PORTFOLIOLCR8A,.

    SURFACESTANDARD ASSELECTED BYARCHITECT

    L10B LED CYLINDER

    16 HIGH X 8INCH

    DIAMETERWITH 6 INCH

    APERTURE

    994000 LUMEN30 DEGREE

    0-10 DIMMINGELECTRONIC

    UNIVERSALVOLTAGE

    GOTHAM INCITO, PORTFOLIOLCR8A,.

    SURFACESTANDARD ASSELECTED BYARCHITECT

    L11 LED STEP LIGHT5 1/4 X 2 7/8 X

    42.1

    36 LUMEN3000K

    ELELCTRONICNON DIM

    120 VBEGA 1325 LED OR PRE BID

    APPROVEDRECESSED WALL

    STANDARD ASSELECTED BYARCHITECT

    L12 RECESSSED SMALL DIAMETER2 1/2 INCH

    DIAMETER X 4INCH DEEP

    3 WATT120 LUMEN

    3000K ELECTRONIC 120/277V

    BRUCK LEDRA 12 WITH J-BOXAND DRIVER

    RECESSED CEILINGIN DISPLAY CASE

    MATTE CHROME

    L13 LINEAR WET LOCATION LEDNOMINAL 8

    INCH WIDE X4 FEET LONG

    39 WATT2975 LUMEN

    4100 K ELECTRONIC 120/277V

    LITHONIA VAP SERIES, OR PRE BIDAPPROVED

    CEILING MOUNTOR SUSPENDED

    STANDARD ASSELECTED BYARCHITECT

    L14SUSPENDED LED CIRCULARDIRECT/INDIRECT

    NOMINAL 5INCH HIGH X

    2 FOOTDIAMETER

    36 WATT270 LUMENSPER FOOT

    REMOTE DRIVERELECTRONIC

    120/277V DELRAY CYLINDRO IIISUSPENDED

    AIRCRAFT CABLE

    STANDARD ASSELECTED BYARCHITECT

    L14 ASUSPENDED LED CIRCULARDIRECT/INDIRECT

    NOMINAL 5INCH HIGH X

    4 FOOTDIAMETER

    54 WATTREMOTE DRIVER

    ELECTRONIC120/277V DELRAY CYLINDRO III

    SUSPENDEDAIRCRAFT CABLE

    STANDARD ASSELECTED BYARCHITECT

    X UNIVERSAL LED EXIT SIGN 13-7/8 X 8.5 3 WATT GREEN LED ELECTRONIC 120/277VLITHONIA EXTREME SERIES,UNIVERSAL MOUNT WITH

    BATTERY

    STANDARD ASSELECTED BYARCHITECT

    WHITE WITH GREEN LETTERS

    X1 WEATHERPROOF EXIT SIGN 13-7/8 X 8.5 3 WATT GREEN LED ELECTRONIC 120/277VLITHONIA EXTREME SERIES,UNIVERSAL MOUNT WITH

    BATTERY

    STANDARD ASSELECTED BYARCHITECT

    WEATHERPROOF ENCLOSURE

    S1 SITE AREA LED POLE LIGHT20 INCH

    DIAMETER135 14000 LUMEN

    DUAL DRIVERFOR LIGHT

    REDUCTION

    UNIVERSALVOLTAGE

    LITHONIA OMERO SERIES TYPE VDISTRIBUTION, OR PRE BID

    APPROVED

    STANDARD ASSELECTED BYARCHITECT

    18 FOOT POLE ON FLUSH BASE SEEDETAIL

    S2 SITE AREA LED POLE LIGHT20 INCH

    DIAMETER135 14000 LUMEN

    DUAL DRIVERFOR LIGHT

    REDUCTION

    UNIVERSALVOLTAGE

    LITHONIA OMERO SERIES TYPE IVDISTRIBUTION, OR PRE BID

    APPROVED

    STANDARD ASSELECTED BYARCHITECT

    18 FOOT POLE ON FLUSH BASE SEEDETAIL

    S3 SITE LED LIGHT COLUMN8 INCH WIDEX 8 FEET TALL

    401100 LUMEN

    4000K ELECTRONIC 120/277V

    BEGA 7844 SERIES, OR PRE BIDAPPROVED

    STANDARD ASSELECTED BYARCHITECT

    FLUSH BASE

    S3ASAME AS TYPE S3 EXCEPT 5 FOOTINSTALLED HEIGHT

    8 INCH WIDEX 8 FEET TALL

    401100 LUMEN

    4000K ELECTRONIC 120/277V

    BEGA 7844 SERIES, OR PRE BIDAPPROVED

    STANDARD ASSELECTED BYARCHITECT

    FLUSH BASE

    S4 SITE LED BOLLARD8 INCH

    DIAMETER X36 INCH HIGH

    12435 LUMEN

    3500K ELECTRONIC 120/277V

    SELUX NOTCH, OR PRE BIDAPPROVED

    STANDARD ASSELECTED BYARCHITECT

    SEE BASE DETAIL

    S5WALL MOUNTED LED BUILDINGMOUNTED

    16 INCH WIDEX 8 INCH

    HIGH24

    2000 LUMENTYPE III 4000 K

    ELECTRONIC 120/277VLITHONIA WST, OR PRE BID

    APPROVED

    STANDARD ASSELECTED BYARCHITECT

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :25:4

    7 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    LU

    MIN

    AIR

    E S

    CH

    ED

    ULE

    2 O

    F 2

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E003

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    MATCHLINE

    S3AS3AS3A

    S3A

    S3A

    S3A

    S3A

    S12S12

    S22 S22

    S3A

    S3A

    S3A

    S4

    S4

    S4

    S4

    S4

    S4

    3

    S3A

    S3A

    S3A

    54

    6

    7

    11

    1-1/2"C 1-1/2"C

    21D1:38

    21D1:40,42

    rsa04

    rsa05

    rsa05

    rsa05

    rsa05

    rsa05

    rsa05

    rsa01rsa02

    rsa03

    rsa03

    rsa03

    rsa03

    rsa03

    rsa03

    rsa01rsa02

    rsa01rsa02

    rsa01rsa02

    rsa03

    rsa03 rsa03 rsa03

    rsa06

    rsa06

    rsa06

    8

    9

    10

    S4rsa05

    S4 rsa05

    S4rsa05

    S4rsa05

    S4

    rsa05

    S4

    rsa05

    1 1

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :25:5

    4 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    SIT

    E P

    LA

    N -

    ELE

    CT

    RIC

    AL

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E010

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

    1" = 20'-0"1 SITE PLAN - ELECTRICAL

    NOTES:

    1. PROVIDE 1-1/2" CONDUIT TO MDF FOR SECURITY CAMERAWIRING BY OTHERS.

    2. PROVIDE (2) RELAYS PER POLE FOR LIGHT REDUCTION BASEDON TIME CLOCK INPUT.

    3. TRANSFORMER VAULT. UTILITY VAULT CO MODEL 712-LAREFERENCE EWEB DRAWINGS FOR ADDITIONAL INFORMATION.

    4. PROVIDE ELECTRICAL CONNECTION TO 1/2 HP PUMP IN DCDBFP VAULT.

    5. PROVIDE ELECTRICAL CONNECTION (2-#4AWG CU AND 1-#6AWG CU GRD) TO EACH OF THE TWO (2) 1500 WATT HEATERS INRP BFP VAULT.

    6. MONUMENT SIGN. PROVIDE 1 INCH CONDUIT FROM SIGN TOMDF. CONDUIT TO BE USED FOR DATA CABLING TO SIGN.CABLING BY OTHERS.

    7. EXISTING IRRIGATION WELL CONTROLLER TO BE RELOCATED.DISCONNECT TEMPORARY ELECTRICAL CONNECTION FROMEXISTING HOWARD ELEMENTARY SCHOOL AND FROMCONTROLLER TO WELL PUMP.

    8. IRRIGATION WELL PUMP.

    9. NEW LOCATION FOR IRRIGATION WELL CONTROLLER.PROVIDE NEW ELECTRICAL CONNECTION.

    10. PROVIDE 1 INCH CONDUIT FOR CONTROL WIRING AND (2) 10AWG CONDUCTORS WITH (1) 10 AWG GROUND IN A 1" CONDUITFOR POWER.

    NO

    RT

    H

    GENERAL NOTES:

    A. ELECTRICAL WORK SHOWN IS DIAGRAMMATIC AND IS MEANTTO REPRESENT GENERAL ROUTING AND EQUIPMENT LOCATIONS.NOT EVERY BEND, OFFSET, PULLBOX, ETC, IS SHOWN.CONTRACTOR SHALL PROVIDE ALL WORK REQUIRED FOR ACOMPLETE INSTALLATION.

    B. COORDINATE ALL UNDERGROUND SITE WORK WITH EXISTINGAND NEW UTILITIES.

    C. ALL BRANCH CIRCUITING AT BUILDING EXTERIOR AND SITESHALL BE #10AWG MINIMUM, UNLESS OTHERWISE NOTED.

    D. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCHCIRCUIT.

    E. REFER TO LIGHTING RELAY SCHEDULE ON SHEET E703 FORADDITIONAL INFORMATION.

    F. PROVIDE NO MORE THAN (6) CURRENT CARRYINGCONDUCTORS (INCLUDING NEUTRAL) PER HOMERUN.

    G. COORDINATE INSTALLATION OF NEW ELECTRICAL SERVICEWITH EWEB.

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    3

    2

    6

    1

    4

    X1

    X1

    7

    7

    rsa07

    rsa07 rsa07 rsa07rsa07

    rsa07S3A

    S3A S3A S3AS3A

    S3A

    X1

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :26:0

    6 P

    MC

    :\R

    evi

    t Loca

    l File

    s\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.

    hansen.r

    vt

    SIT

    E P

    LA

    N -

    ELE

    CT

    RIC

    AL

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E011

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

    1" = 20'-0"1 SITE PLAN - ELECTRICAL

    NOTES:

    1. EXISTING 5 INCH CONDUIT WEST OF THIS AREA INSTALLEDUNDER KELLY MIDDLE SCHOOL TRACK PROJECT. CONDUIT TO BEUTILIZED FOR NEW SERVICE TO HOWARD ELEMENTARY SCHOOL.EXTEND CONDUIT AS INDICATED.

    2. SECTIONALIZING VAULT. PROVIDE UTILITY VAULT CO MODEL575-FUSE-PCORP. REFERENCE EWEB DRAWINGS FOR ADDITIONALINFORMATION.

    3. PROVIDE ONE (1) 3 INCH CONDUIT.

    4. TRANSFORMER VAULT. PROVIDE UTILITY VAULT CO MODEL 712-LA. REFERENCE EWEB DRAWINGS FOR ADDITIONALINFORMATION.

    5. NOT USED.

    6. LIGHTING ALLOWANCE OF $1000.00 FOR PLAY STRUCTURE.PROVIDE RELAY BASED CONTROL WITH MANUAL OVERRIDESWITCH IN P/E OFFICE. VERIFY EXACT LOCATION. CONFIGUREFOR PE CELL ON/TIME CLOCK OFF OPERATION.

    7. PROVIDE 1 INCH CONDUIT FROM CENTER GATE POST TO MDFFOR ACCESS CONTROL CABLING.

    NO

    RT

    H

    GENERAL NOTES:

    A. ELECTRICAL WORK SHOWN IS DIAGRAMMATIC AND IS MEANT TOREPRESENT GENERAL ROUTING AND EQUIPMENT LOCATIONS. NOTEVERY BEND, OFFSET, PULLBOX, ETC, IS SHOWN. CONTRACTORSHALL PROVIDE ALL WORK REQUIRED FOR A COMPLETEINSTALLATION.

    B. COORDINATE ALL UNDERGROUND SITE WORK WITH EXISTINGAND NEW UTILITIES.

    C. COORDINATE INSTALLATION OF NEW ELECTRICAL SERVICEWITH EWEB.

    D. ALL BRANCH CIRCUITING AT BUILDING EXTERIOR AND SITE SHALLBE #10AWG MINIMUM, UNLESS OTHERWISE NOTED.

    E. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCHCIRCUIT.

    F. REFER TO LIGHTING RELAY SCHEDULE ON SHEET E703 FORADDITIONAL INFORMATION.

    G. PROVIDE NO MORE THAN (6) CURRENT CARRYINGCONDUCTORS (INCLUDING NEUTRAL) PER HOMERUN.

    H. PROVIDE CONNECTION TO EXIT SIGNS FROM THE NEARESTEMERGENCY CIRCUIT WITH AN UNSWITCHED LEG.

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    21

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :26:1

    1 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    SIT

    E P

    LA

    N -

    ELE

    CT

    RIC

    AL

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E012

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

    1" = 20'-0"1 SITE PLAN - ELECTRICAL

    NOTES:

    1. APPROXIMATE LOCATION OF EXISTING EWB VAULT NO. V4052.

    2. EXISTING 5 INCH CONDUIT INSTALLED UNDER KELLY MIDDLESCHOOL TRACK PROJECT. CONDUIT TO BE UTILIZED FOR NEWSERVICE TO HOWARD ELEMENTARY SCHOOL.

    NO

    RT

    H

    GENERAL NOTES:

    A. ELECTRICAL WORK SHOWN IS DIAGRAMMATIC AND IS MEANTTO REPRESENT GENERAL ROUTING AND EQUIPMENT LOCATIONS.NOT EVERY BEND, OFFSET, PULLBOX, ETC, IS SHOWN.CONTRACTOR SHALL PROVIDE ALL WORK REQUIRED FOR ACOMPLETE INSTALLATION.

    B. COORDINATE ALL UNDERGROUND SITE WORK WITH EXISTINGAND NEW UTILITIES.

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    CAFETERIA

    A103

    A BEXIT

    ENTRY

    EXIT

    TRAYRETURN

    ENTRY

    CAFETERIA

    A103

    A BEXIT

    ENTRY

    EXIT

    TRAYRETURN

    ENTRY

    CLASSROOM

    B127

    CLASSROOM

    B126

    COMMONS

    B130

    CLASSROOM

    B129

    CLASSROOM

    B131

    LIFE SKILLS

    B125RECEPTION

    B100

    VESTIBULE

    A100

    CLASSROOM

    B146

    COMMONS

    B145

    MULTIPURPOSE

    B149

    CLASSROOM

    B148CLASSROOM

    B150

    CLASSROOM

    B144

    CLASSROOM

    C113

    MULTIPURPOSE

    C112

    CLASSROOM

    C111

    CLASSROOM

    C109

    COMMONS

    C108

    CLASSROOM

    C107

    BOILER

    A119

    BLDG STORAGE

    A117

    COMMUNITY ROOM

    A102

    GIRLS

    B142

    TOILET

    B112

    GIRLS

    B123

    MDF

    B120

    HALLWAY

    B128

    TOILET

    B104

    BOYS

    B141

    GIRLS

    C104

    PE OFC/STG

    A114

    CUSTODIAL

    A116

    ELEC

    A118

    BOYS

    A109

    GIRLS

    A110

    FAMILY TOILET

    A107

    TBL STORAGE

    A105

    GYM

    A111

    MUSIC ROOM / STAGE

    A113

    LOBBY

    A101

    LOST AND FOUND

    A115

    CUST

    A104C

    PRINCIPAL

    B102

    CONFERENCE

    B110

    SECRETARY

    B101

    QUIET

    B105

    CLOSET

    B109

    VOLUNTEER

    B117

    SENSORY ROOM

    B115

    LACTATION RM

    B111

    HEALTH

    B106

    OFFICE

    B107

    CUST

    B138

    IDF

    C101

    STAFF TOILET

    C103

    STAFF TOILET

    B140

    SMALL GROUP

    B134

    OFFICE

    B136

    BOYS

    C105

    SOR

    C102

    SMALL GROUP

    B116

    MOTOR SKILLS

    B114

    WORKROOM

    B113

    HEALTH TOILET

    B108

    BOYS

    B122

    SOR

    B139

    CAFETERIA

    A103

    KITCHEN

    A104

    PE CIRCULATION

    A106 CUST

    A112

    STAFF ROOM

    B103

    HALLWAY

    B119

    ELEVATOR

    B118

    HALLWAY

    B124

    CHANGING TOILET

    B125C

    MEDIA CENTER

    B132

    MEDIA WORK RM

    B133

    STAIR

    B132B

    STAIR

    B132A

    HALLWAY

    B143

    HALLWAY

    B147HALLWAY

    C100

    HALLWAY

    C106

    HALLWAY

    C110

    SOR

    B121

    KITCHEN

    A104D

    CHANGING

    B125D

    HALLWAY

    B137

    STAIR

    C114

    RAMP

    A121

    STAIR

    B151

    STAIR

    B128A

    HALL

    A106B

    HALLWAY

    B137STORY COVE

    B135

    WF

    A120

    H

    1 2

    3

    4

    5 68

    9 10 12 13 14 15

    N

    S

    LL

    C

    R

    Q

    M

    E

    F

    G

    D

    B

    6.2 6.8 8.2 11

    B.3

    B.7 B.8

    D.9

    G.1

    H.2

    J

    K

    P

    4.3

    P.7

    13.67.8

    B.5

    0.911.9

    5

    (1) 1 INCH C.

    1

    (3) 2 INCH C.

    1

    (2) 2 INCH C.

    (4) 2 INCH C.

    (4) 2 INCH C.

    (2) 2 INCH C.

    4

    2

    2

    2

    4

    4

    3

    5.41.9

    A

    B

    C

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :26:1

    7 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    OV

    ER

    ALL E

    LE

    CT

    RIC

    AL P

    LA

    N -

    TE

    LE

    CO

    MM

    UN

    ICA

    TIO

    NS

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E013

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

    NOTES:

    1. COORDINATE EXACT LOCATION OF CONDUIT STUB UPS WITHTELECOMMUNICATIONS DRAWINGS.

    2. (1) 1"C STUB UP IN CABINET VOID.

    3. REFERENCE SHEET E113 FOR CONTINUATION.

    4. STUB UP IN WALL BASE. REFER TO TECHNOLOGY DRAWINGS FORCONTINUATION.

    5. REFERENCE SHEET E411 AND E412 FOR CONTINUATION.

    1/16" = 1'-0"1 OVERALL ELECTRICAL PLAN - TELECOMMUNICATIONS

    NO

    RT

    H

    GENERAL NOTES:

    A. ELECTRICAL WORK SHOWN IS DIAGRAMMATIC AND IS MEANTTO REPRESENT GENERAL ROUTING AND EQUIPMENT LOCATIONS.NOT EVERY BEND, OFFSET, PULLBOX, ETC, IS SHOWN.CONTRACTOR SHALL PROVIDE ALL WORK REQUIRED FOR ACOMPLETE INSTALLATION.

    B. COORDINATE ALL UNDERGROUND SITE WORK WITH EXISTINGAND NEW UTILITIES.

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    CAFETERIA

    A103

    A BEXIT

    ENTRY

    EXIT

    TRAYRETURN

    ENTRY

    CAFETERIA

    A103

    A BEXIT

    ENTRY

    EXIT

    TRAYRETURN

    ENTRY

    Conduit ID From Equipment To Equipment

    N1 MDP 41A1

    N2 MDP 41C1

    N3 MDP 42C1

    N4 MDP 42A1

    N5 MDP CHILLER

    N6 MDP ELEVATOR

    N7 MDP 4K1

    N8 SDP 2K1

    N9 SDP 21A1

    N10 SDP 21A2

    N11 SDP 21B1

    N12 SDP 21C1

    N14 SDP 22A1

    N15 SDP 22B1

    N16 SDP 22C1

    N19 SDP GYMNASIUM

    L1 41LSD1 42LSA1

    L2 41LSD1 42LSC1

    S1 STDP IDF-1

    S2 STDP IDF-2

    S3 STDP MDF

    S4 STDP 21SBK1

    S5 STDP 21SBA1

    CLASSROOM

    B127

    CLASSROOM

    B126

    COMMONS

    B130

    CLASSROOM

    B129

    CLASSROOM

    B131

    LIFE SKILLS

    B125RECEPTION

    B100

    VESTIBULE

    A100

    CLASSROOM

    B146

    COMMONS

    B145

    MULTIPURPOSE

    B149

    CLASSROOM

    B148CLASSROOM

    B150

    CLASSROOM

    B144

    CLASSROOM

    C113

    MULTIPURPOSE

    C112

    CLASSROOM

    C111

    CLASSROOM

    C109

    COMMONS

    C108

    CLASSROOM

    C107

    BOILER

    A119

    BLDG STORAGE

    A117

    COMMUNITY ROOM

    A102

    GIRLS

    B142

    TOILET

    B112

    GIRLS

    B123

    MDF

    B120

    HALLWAY

    B128

    TOILET

    B104

    BOYS

    B141

    GIRLS

    C104

    PE OFC/STG

    A114

    CUSTODIAL

    A116

    ELEC

    A118

    BOYS

    A109

    GIRLS

    A110

    FAMILY TOILET

    A107

    TBL STORAGE

    A105

    GYM

    A111

    MUSIC ROOM / STAGE

    A113

    LOBBY

    A101

    LOST AND FOUND

    A115

    CUST

    A104C

    PRINCIPAL

    B102

    CONFERENCE

    B110

    SECRETARY

    B101

    QUIET

    B105

    CLOSET

    B109

    VOLUNTEER

    B117

    SENSORY ROOM

    B115

    LACTATION RM

    B111

    HEALTH

    B106

    OFFICE

    B107

    CUST

    B138

    IDF

    C101

    STAFF TOILET

    C103

    STAFF TOILET

    B140

    SMALL GROUP

    B134

    OFFICE

    B136

    BOYS

    C105

    SOR

    C102

    SMALL GROUP

    B116

    MOTOR SKILLS

    B114

    WORKROOM

    B113

    HEALTH TOILET

    B108

    BOYS

    B122

    SOR

    B139

    CAFETERIA

    A103

    KITCHEN

    A104

    PE CIRCULATION

    A106 CUST

    A112

    STAFF ROOM

    B103

    HALLWAY

    B119

    ELEVATOR

    B118

    HALLWAY

    B124

    CHANGING TOILET

    B125C

    MEDIA CENTER

    B132

    MEDIA WORK RM

    B133

    STAIR

    B132B

    STAIR

    B132A

    HALLWAY

    B143

    HALLWAY

    B147HALLWAY

    C100

    HALLWAY

    C106

    HALLWAY

    C110

    SOR

    B121

    KITCHEN

    A104D

    CHANGING

    B125D

    HALLWAY

    B137

    STAIR

    C114

    RAMP

    A121

    STAIR

    B151

    STAIR

    B128A

    HALL

    A106B

    HALLWAY

    B137STORY COVE

    B135

    WF

    A120

    H

    1 2

    3

    4

    5 68

    9 10 12 13 14 15

    NN

    SS

    LL

    C

    R

    QQ

    M

    E

    FF

    G

    D

    B

    6.2 6.8 8.2 11

    B.3

    B.7 B.8

    D.9

    G.1

    H.2

    J

    K

    P

    4.3

    P.7

    13.6

    E.7

    7.8

    B.5

    0.911.9

    N7

    N5

    N2

    N3

    S4

    N8

    N16

    L2

    N12

    S2N11

    S1

    N15

    N6

    N19

    N4

    N14

    L1

    1

    N10

    S5

    N1

    N9

    S3

    2

    11

    5.41.9

    TO CHILLER

    A

    B

    C

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :26:2

    4 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    OV

    ER

    ALL E

    LE

    CT

    RIC

    AL P

    LA

    N -

    PO

    WE

    RE

    UG

    EN

    E S

    CH

    OO

    L D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E014

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

    1/16" = 1'-0"1 OVERALL ELECTRICAL PLAN - POWER

    NOTES:

    1. CONDUITS TO BE ROUTED TO PANELS ON SECOND FLOOR.

    2. STUB INTO ELEVATOR MACHINE ROOM.

    GENERAL NOTES:

    A. ALL UNDER SLAB CONDUITS TO BE COORDINATED WITH OTHER TRADES.

    B. REFERENCE FLOOR PLANS FOR ADDITIONAL INFORMATION.

    C. CONDUIT ROUTING SHOWN ON DRAWINGS IS DIAGRAMMATIC. CONDUITS TOBE ROUTED IN A DIRECT LINE. REFERENCE SPECIFICTION FOR ADDITIONALINFORMATION.

    NONE2 CONDUIT SCHEDULE

    NO

    RT

    H

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    3

    4

    1

    2

    (E) 3 INCH C.

    (2) 4 INCH C.

    (2) 2 INCH C.(2) 4 INCH C.

    (2) 2 INCH C.(2) 4 INCH C.

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :26:3

    9 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    OV

    ER

    ALL S

    ITE

    PLA

    NT

    ELE

    CO

    MM

    UN

    ICA

    TIO

    NS

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E015

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

    1" = 30'-0"1 OVERALL SITE PLAN - TELECOMMUNICATIONS

    NOTES:

    1. UTILITY VAULT CO. MODEL TA25 VAULT. INTERCEPT CONDUIT FROM KELLYMIDDLE SCHOOL.

    2. COORDINATE CONDUIT STUB UP LOCATIONS WITH TELECOMMUNICATIONSDRAWINGS.

    3. UTILITY VAULT CO. MODEL TA25 VAULT.

    4. STUB CONDUITS UP AT BASE OF POLE.

    NO

    RT

    H

    GENERAL NOTES:

    A. ELECTRICAL WORK SHOWN IS DIAGRAMMATIC AND IS MEANT TOREPRESENT GENERAL ROUTING AND EQUIPMENT LOCATIONS. NOT EVERYBEND, OFFSET, PULLBOX, ETC, IS SHOWN. CONTRACTOR SHALL PROVIDEALL WORK REQUIRED FOR A COMPLETE INSTALLATION.

    B. COORDINATE ALL UNDERGROUND SITE WORK WITH EXISTING AND NEWUTILITIES.

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    CAFETERIA

    A103

    A BEXIT

    ENTRY

    EXIT

    TRAYRETURN

    ENTRY

    CAFETERIA

    A103

    A BEXIT

    ENTRY

    EXIT

    TRAYRETURN

    ENTRY

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    VESTIBULE

    A100

    BOILER

    A119

    BLDG STORAGE

    A117

    COMMUNITY ROOM

    A102

    PE OFC/STG

    A114

    CUSTODIAL

    A116

    ELEC

    A118

    BOYS

    A109

    GIRLS

    A110

    FAMILY TOILET

    A107

    TBL STORAGE

    A105

    GYM

    A111

    MUSIC ROOM / STAGE

    A113

    LOBBY

    A101

    LOST AND FOUND

    A115

    CUST

    A104C

    CAFETERIA

    A103

    KITCHEN

    A104

    PE CIRCULATION

    A106

    CUST

    A112

    KITCHEN

    A104D

    RAMP

    A121

    HALL

    A106B

    WF

    A120

    GFCI

    GENERATORREMOTE

    ANNUNCIATOR

    PANEL 2K1

    PANEL 21SBK1

    GFCI

    PANEL 4K1

    /1 E115

    E411

    1

    /1

    E113

    GFCI

    GFCI

    GFCI

    100 AMPENCLOSED

    CIRCUITBREAKER

    H

    1 2 4

    G

    D

    B

    6.2 6.8

    B.3

    B.7B.8

    D.9

    F.2

    G.1

    H.2

    B.5

    GFCI

    E181

    1

    A

    10

    6

    5

    5

    7

    8

    7

    6

    8

    9

    15.

    13.

    11. 11.

    11.17.

    17.

    7. 7. 7. 7.

    5.

    5.5.

    5.

    1.

    1.

    1.

    1.

    1.

    3.

    3.

    3.

    3.

    9.

    39.

    35.

    41.

    9.

    27.

    27.

    27.

    9.

    37.9.

    14.

    33.

    21.

    21.

    21.

    31.

    21.

    21.

    23.23.

    2.

    4.

    6.

    2.

    8. 10.12.

    8.

    14.

    43.

    5

    5

    5

    5

    5

    2

    2

    2

    45.

    12.

    43.

    52.

    50.

    48.44.

    46.

    41.

    TP-01

    33.

    1

    33.

    1

    55,57.

    1

    EF-CUST

    35.

    +96" AFF

    13.4

    13.+72" AFF

    3

    8.

    3 +72" AFF

    27.

    GFCI

    A

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :26:4

    9 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    SE

    CT

    OR

    A P

    OW

    ER

    PLA

    N -

    FIR

    ST

    FLO

    OR

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E111

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

    1/8" = 1'-0"1 SECTOR A POWER PLAN - FIRST FLOOR

    NO

    RT

    H

    NOTES:

    1. PROVIDE CONNECTION TO SECTIONAL DOORS.

    2. PROVIDE CONNECTION TO HAND DRYER.

    3. PROVIDE CONNECTION TO A/V EQUIPMENT LOCATED ABOVE CEILING.COORDINATE EXACT LOCATION WITH A/V DRAWINGS.

    4. RECEPTACLE FOR SHORT THROW PROJECTOR.

    5. MOTORIZED SHADE AT SKYLIGHT. COORDINATE EXACT LOCATION WITHARCHITECT.

    6. MOTORIZED PROJECTION SCREEN. COORDINATE MOUNTING HEIGHT WITHARCHITECT.

    7. MOTORIZED RETRACTABLE BASKETBALL HOOP.

    8. CEILING MOUNTED RECEPTACLE FOR PROJECTOR. COORDINATE EXACTLOCATION WITH A/V DRAWINGS.

    9. RECEPTACLES TO SERVE AUDIO EQUIPMENT. RECEPTACLES TO BE INSTALLED INCABINETRY. COORDINATE EXACT LOCATION WITH ARCHITECT.

    10. RECEPTACLES TO SERVE AUDIO EQUIPMENT. AUDIO EQUIPMENT TO BEINSTALLED IN A FREESTANDING RACK.

    GENERAL NOTES:

    A. REFERENCE SHEETS E013 AND E014 FOR UNDERGROUND CONDUITS FORFEEDERS AND DATA CABLING.

    B. COORDINATE ALL UNDERGROUND SITE WORK WITH EXISTING AND NEWUTILITIES.

    C. ALL BRANCH CIRCUITING AT BUILDING EXTERIOR AND SITE SHALL BE #10AWGMINIMUM, UNLESS OTHERWISE NOTED.

    D. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT.

    E. REFER TO LIGHTING RELAY SCHEDULE ON SHEET E703 FOR ADDITIONALINFORMATION.

    F. ALL RECEPTACLES SHOWN ON THIS SHEET SHALL BE PROVIDED WITH BRANCHCIRCUITS FROM PANEL '21D1,' UNLESS OTHERWISE NOTED.

    G. ALL BRANCH CIRCUITING SHALL BE #10AWG., UNLESS OTHERWISE NOTED.

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    JJ

    J

    J

    J

    J

    J J

    J

    J JJ

    J J

    CLASSROOM

    B127

    CLASSROOM

    B126

    COMMONS

    B130

    CLASSROOM

    B129

    CLASSROOM

    B131

    LIFE SKILLS

    B125

    RECEPTION

    B100

    CLASSROOM

    B146

    COMMONS

    B145

    MULTIPURPOSE

    B149

    CLASSROOM

    B148

    CLASSROOM

    B150

    CLASSROOM

    B144

    GIRLS

    B142

    TOILET

    B112

    GIRLS

    B123

    MDF

    B120

    HALLWAY

    B128

    TOILET

    B104

    BOYS

    B141

    PRINCIPAL

    B102

    CONFERENCE

    B110

    SECRETARY

    B101

    QUIET

    B105

    CLOSET

    B109

    VOLUNTEER

    B117

    SENSORY ROOM

    B115

    LACTATION RM

    B111

    HEALTH

    B106

    OFFICE

    B107

    CUST

    B138

    STAFF TOILET

    B140

    SMALL GROUP

    B134

    OFFICE

    B136

    BOYS

    C105

    SMALL GROUP

    B116

    MOTOR SKILLS

    B114

    WORKROOM

    B113

    HEALTH TOILET

    B108

    BOYS

    B122

    SOR

    B139

    STAFF ROOM

    B103

    HALLWAY

    B119

    ELEVATOR

    B118

    HALLWAY

    B124

    CHANGING TOILET

    B125C

    MEDIA CENTER

    B132

    MEDIA WORK RM

    B133

    STAIR

    B132B

    STAIR

    B132A

    HALLWAY

    B143

    HALLWAY

    B147

    SOR

    B121

    CHANGING

    B125D

    HALLWAY

    B137

    STAIR

    B151

    STAIR

    B128A

    HALLWAY

    B137

    STORY COVE

    B135

    GFCI

    GFCI

    GFCI

    PANEL 21SBA1

    PANEL MDF

    PANEL 21B1

    GFCI GFCI

    GFCI

    GFCI

    GFCI

    PANEL 21A1

    GFCI GFCIGFCI

    GFCI GFCIGFCI

    /1 E115

    PANEL 21A2

    PANEL 41A1

    12"x4" BOCT: 9' - 6"

    12"x4" BOCT: 9' - 6"

    /1

    E111

    /1 E111

    GFCI GFCI

    8

    (2) 4 INCH AND (4) 1 INCH C. 10

    7

    29

    GFCI

    2

    3

    GFCI

    GFCI

    6

    11

    H

    8 9 10 12 13 14 15

    N

    S

    L

    C

    R

    Q

    M

    E

    F

    G

    D

    6.8 8.2 11

    B.8

    F.2

    J

    K

    P

    P.7

    13.6

    E.7

    7.8

    +96" AFF

    13

    12

    5

    15

    15

    GFCIGFCI

    14

    1

    GFCI

    GFCI

    GFCI

    2

    4

    13

    +96" AFF 12

    13

    +96" AFF 12

    13

    +96" AFF12

    13

    +96" AFF 12

    13

    +96" AFF12

    13

    +96" AFF 12

    13 +96" AFF1213+96" AFF 12

    1

    17

    16

    7

    6.6.

    12.

    49.

    2.

    6.2.

    12.

    10.

    8.

    39.

    2.

    18

    1.1.

    11.

    1.

    5.1.

    11.

    9.

    7.

    3.

    5.

    17.

    23.

    45.

    13.

    17.13.

    23.

    21.

    19.

    17.

    37.

    13.25. 29.

    29.

    35.

    43.

    25.

    29.25.

    35.

    33.

    31.

    18.18.

    24.

    51.

    14.

    18.14.

    24.

    22.

    20.

    39.

    14.

    17.

    13.

    17.

    23.

    41.

    17.13.

    35.

    17.

    23.

    21.

    19.

    13.

    21

    5. 1.

    1.

    5.

    11.

    43.

    5.1.

    11.

    9.

    7.

    25.

    2.6.

    6.

    12.

    45.

    6.2.

    12.

    10.

    8.

    2.

    13

    24.

    22.

    20.

    18.

    14.

    27.

    +96" AFF 12

    47.

    18.

    24.

    14.

    18.

    14.30.

    34.

    32.

    36.

    30.

    26.

    36.

    30.

    49.

    26.

    26.

    GFCI27.

    29.

    29. 29.

    25.

    31.

    31.21C1: 41.

    21C1: 41.

    20

    19

    2.

    2.3.

    1.

    1.

    4,6.

    41.

    37.

    10.

    12.

    10.

    14.

    18.

    16.

    10.

    8.

    8.

    8.

    6.

    6.

    4.

    4.

    27. 27.

    2.

    2.

    2.

    25. 25. 23.

    23.

    27. 27.

    27.

    25.

    21. 21.

    21.21.

    21.

    19. 17.

    19.

    19.

    19.

    37.

    3.

    5.

    3.

    3.

    5.

    5.

    1.

    1.

    1.

    7.

    9.

    7.

    9.

    7.

    15. 7.15.

    11.

    11.

    13. 13.

    13.

    11.

    21D1:14.

    3.

    5.

    5. 5.

    3.

    3.

    19.

    21.

    7.

    7.9.

    11.

    13. 15.17.

    17.17.

    23 23

    23

    23

    23

    23

    2323

    24 24

    24

    3.

    29.

    31.

    33.

    40.

    10.

    23

    34.

    32.

    38.

    36.

    20.

    22,29.30.

    10.

    42.

    26

    25

    26.

    28.

    +72" AFF

    2743.

    43.

    28

    +72" AFF51.

    51.

    27

    28

    +72" AFF

    2745.

    45.

    28

    +72" AFF27

    47. 47.

    28

    47.

    +72" AFF 49.49.

    27

    28

    21C1: 35.

    21C1: 37.

    37.

    39.

    35.

    33. +72" AFF49.

    49.

    27

    28

    +72" AFF 45.45.

    27

    28

    +72" AFF47.

    47.

    27

    28

    +72" AFF

    27

    41.41.

    28

    +72" AFF

    27

    43. 43.

    28

    23

    TP-05

    21.

    35.

    30

    23.

    30 30 11.

    30

    30

    30

    30

    30

    30

    30

    12.24.

    23.

    36.

    24.

    12.

    11.

    23

    13.

    +96" AFF

    FCU-MDF

    EF-MDF

    AH-OFCS

    B

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :26:5

    6 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    SE

    CT

    OR

    B P

    OW

    ER

    PLA

    N -

    FIR

    ST

    FLO

    OR

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E113

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

    1/8" = 1'-0"1 SECTOR B POWER PLAN - FIRST FLOOR

    NO

    RT

    H9

    NOTES:

    1. REFRIGERATOR.

    2. MICROWAVE.

    3. WASHER/DRYER. PROVIDE A NEMA 14-30R RECEPTACLE.

    4. DISHWASHER.

    5. COPIER.

    6. PROVIDE (3) 4 INCH AND (2) 1 INCH CONDUITS FROM CABLE TRAY TO MDF B120. CONDUITSTO BE STUBBED OUT ABOVE CABLE TRAY. REFERENCE TELECOMMUNICATIONS DRAWINGSFOR MDF LAYOUT.

    7. PROVIDE (3) 4 INCH AND (2) 2 INCH CONDUITS FROM CABLE TRAY TO CUST B138.CONDUITS TO BE STUBBED OUT NEAR CEILING.

    8. PROVIDE (3) 4 INCH AND (2) 2 INCH CONDUIT SLEEVES UP TO IDF B238 ABOVE.

    9. REFERENCE SHEET E013 FOR UNDERSLAB DATA CONDUIT ROUTING.

    10. CONDUITS TO BE ROUTED FROM CEILING SPACE OF CUST B138 TO IDF C101.

    11. PROVIDE (3) 4 INCH AND (2) 2 INCH CONDUIT SLEEVES UP TO WORKROOM B218 ABOVE.

    12. RECEPTACLE FOR SHORT THROW PROJECTOR.

    13. RECEPTACLE FOR TABLET CHARGING. RECEPTACLE TO BE INSTALLED IN CABINETRY.COORDINATE EXACT LOCATION WITH ARCHITECT.

    14. RECEPTACLE TO BE MOUNTED IN CASEWORK.

    15. RECEPTACLE TO BE MOUNTED IN KNEE SPACE.

    16. MOTORIZED PROJECTION SCREEN. COORDINATE MOUNTING HEIGHT/LOCATION WITHARCHITECT.

    17. CEILING MOUNTED RECEPTACLE FOR PROJECTOR. COORDINATE EXACT LOCATION WITHA/V DRAWINGS.

    18. ALL RECEPTACLES SHOWN IN THIS AREA SHALL BE PROVIDED WITH BRANCH CIRCUITSFROM PANEL '21A1', UNLESS OTHERWISE NOTED.

    19. ALL RECEPTACLES DESIGNATED AS EMERGENCY IN THIS AREA SHALL BE PROVIDED WITHBRANCH CIRCUITS FROM PANEL '21SBA1', UNLESS OTHERWISE NOTED.

    20. ALL RECEPTACLES SHOWN IN THIS AREA SHALL BE PROVIDED WITH BRANCH CIRCUITSFROM PANEL '21A2', UNLESS OTHERWISE NOTED.

    21. ALL RECEPTACLES SHOWN IN THIS AREA SHALL BE PROVIDED WITH BRANCH CIRCUITSFROM PANEL '21B1', UNLESS OTHERWISE NOTED.

    22. ALL RECEPTACLES IN THIS ROOM TO BE INSTALLED AT +48" AFF.

    23. PROVIDE CONNECTION TO HAND DRYER.

    24. PROVIDE CONNECTION TO ADA DOOR MOTOR AND OPERATORS. COORDINATE EXACTLOCATIONS OF DOOR OPERATORS WITH ARCHITECT.

    25. ALL RECEPTACLES IN MDF B120 SHALL BE PROVIDED WITH BRANCH CIRCUITS FROMPANEL ' MDF', UNLESS OTHERWISE NOTED.

    26. PROVIDE A NEMA L6-30 CENTER ABOVE THE IT RACK. COORDINATE EXACT LOCATIONWITH IT CONSULTANT.

    27. RECEPTACLE TO SERVE VIDEO MONITOR.

    28. PROVIDE CONNECTION TO A/V EQUIPMENT LOCATED ABOVE CEILING. COORDINATEEXACT LOCATION WITH A/V DRAWINGS.

    29. ROUTE HOMERUN CONDUIT UNDER SLAB TO NEAREST WALL.

    30. RECEPTACLE FOR MONITOR SHALL BE MOUNTED AT 60" AFF, BELOW PROJECTORRECEPTACLE.

    GENERAL NOTES:

    A. REFERENCE SHEETS E013 AND E014 FOR UNDERGROUND CONDUITSFOR FEEDERS AND DATA CABLING.

    B. AREA ABOVE ALL ELECTRICAL PANELS AND SWITCH BOARDS SHALLBE KEPT CLEAR OF ALL EQUIPMENT FOREIGN TO THE ELECTRICALINSTALLATION INCLUDING PIPING, DUCTWORK, SUPPORTS, ETC.COORDINATE INSTALLATION WITH ALL OTHER TRADES.

    C. ALL PENETRATIONS AND ROUTING PATHS OF EXPOSED CONDUITSHALL BE COORDINATED AND REVIEWED BY ARCHITECT AND ENGINEERPRIOR TO INSTALLATION.

    D. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCHCIRCUIT, SHARED NEUTRALS ARE NOT PERMITTED.

    E. PROVIDE NO MORE THAN (6) CURRENT CARRYING CONDUCTORS PERHOMERUN.

    F. ALL BRANCH CIRCUITING SHALL BE #10AWG., UNLESS OTHERWISENOTED.

    G. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE ONSHEET E702 FOR ADDITIONAL INFORMATION.

    22

    22

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    J

    J

    JJ

    J JJ

    J J

    CLASSROOM

    C113

    MULTIPURPOSE

    C112

    CLASSROOM

    C111

    CLASSROOM

    C109

    COMMONS

    C108

    CLASSROOM

    C107

    GIRLS

    C104

    IDF

    C101

    STAFF TOILET

    C103

    SMALL GROUP

    B134

    BOYS

    C105

    SOR

    C102

    HALLWAY

    C100

    HALLWAY

    C106

    HALLWAY

    C110

    STAIR

    C114

    GFCI

    GFCI

    PANEL 21C1

    PANEL 41C1

    PANEL IDF-2

    GFCI GFCIGFCI

    /1

    E113

    GFCI

    GFCI

    3

    (2) 4 INCH AND (4) 1 INCH C. 24

    1

    3 5 6

    N

    S

    L

    R

    Q

    M

    K

    P

    4.3

    P.7

    GFCIWP

    GFCIWP

    0.9 6.1

    5

    1 +96" AFF

    5

    1+96" AFF

    5

    1+96" AFF

    5

    1 +96" AFF1 +96" AFF

    5

    1.

    11.

    47.

    3.

    1.

    1.

    1.5.

    25.

    3.

    7.

    9.

    11.

    1.

    27.

    6.2.

    2.

    4.

    49.

    2.

    12.

    4. 6. 4.

    4.

    12.

    10.

    8.

    14.

    24.

    22.

    20.

    14.18.

    27.

    14.

    26.

    16.

    51.

    24.

    14.16.14.

    36.

    34.

    32.

    28.26.

    28.

    53.

    36.

    26.

    26.

    30.26.

    27.

    27.

    15.

    13.

    13.

    23.

    45.

    15.

    13.

    17.13.

    13.

    25.

    23.

    21.

    19.

    29.

    25.

    GFCI

    1.3.

    5.

    2.

    2.

    4,6.

    7

    5.41.9

    6

    66

    33.

    31.+72" AFF49.

    49.

    9

    10

    +72" AFF 53.53.

    9

    10

    +72" AFF 51.51.

    9

    10

    +72" AFF

    9

    47.47.

    10

    +72" AFF

    9

    45. 45.

    10

    87

    43.

    39.

    29.

    I42.

    11

    12.

    24. 36.

    23.12

    1212 12

    1211.

    12"x4" BOCT: 9' - 6"

    C

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :27:0

    1 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    SE

    CT

    OR

    C P

    OW

    ER

    PLA

    N -

    FIR

    ST

    FLO

    OR

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E115

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

    1/8" = 1'-0"1 SECTOR C POWER PLAN - FIRST FLOOR

    NO

    RT

    H

    NOTES:

    1. RECEPTACLE FOR SHORT THROW PROJECTOR.

    2. CONDUITS TO BE ROUTED FROM CEILING SPACE OF IDF C101 TO CUST B138.

    3. PROVIDE (3) 4 INCH AND (2) 2 INCH CONDUIT SLEEVES UP TO CUST C201 ABOVE.

    4. PROVIDE (3) 4 INCH AND (2) 2 INCH CONDUITS FROM CABLE TRAY TO IDF C101.CONDUITS TO BE STUBBED OUT NEAR CEILING.

    5. RECEPTACLE FOR TABLET CHARGING. RECEPTACLE TO BE INSTALLED INCABINETRY. COORDINATE EXACT LOCATION WITH ARCHITECT.

    6. PROVIDE CONNECTION TO HAND DRYER.

    7. ALL RECEPTACLES IN IDF C101 SHALL BE PROVIDED WITH BRANCH CIRCUITSFROM PANEL 'IDF-2', UNLESS OTHERWISE NOTED.

    8. PROVIDE A NEMA L6-30 CENTER ABOVE THE IT RACK. COORDINATE EXACTLOCATION WITH IT CONSULTANT.

    9. RECEPTACLE TO SERVE VIDEO MONITOR.

    10. PROVIDE CONNECTION TO A/V EQUIPMENT LOCATED ABOVE CEILING.COORDINATE EXACT LOCATION WITH A/V DRAWINGS.

    11. PROVIDE CONNECTION TO FSD. REFER TO MECHANICAL DRAWINGS FORADDITIONAL INFORMATION.

    12. RECEPTACLE FOR MONITOR SHALL BE MOUNTED AT 60" AFF, BELOWPROJECTOR RECEPTACLE.

    GENERAL NOTES:

    A. REFERENCE SHEETS E013 AND E014 FOR UNDERGROUND CONDUITS FORFEEDERS AND DATA CABLING.

    B. AREA ABOVE ALL ELECTRICAL PANELS AND SWITCH BOARDS SHALL BEKEPT CLEAR OF ALL EQUIPMENT FOREIGN TO THE ELECTRICALINSTALLATION INCLUDING PIPING, DUCTWORK, SUPPORTS, ETC.COORDINATE INSTALLATION WITH ALL OTHER TRADES.

    C. ALL PENETRATIONS AND ROUTING PATHS OF EXPOSED CONDUIT SHALLBE COORDINATED AND REVIEWED BY ARCHITECT AND ENGINEER PRIORTO INSTALLATION.

    D. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT,SHARED NEUTRALS ARE NOT PERMITTED.

    E. PROVIDE NO MORE THAN (6) CURRENT CARRYING CONDUCTORS PERHOMERUN.

    F. ALL RECEPTACLES SHOWN ON THIS SHEET SHALL BE PROVIDED WITHBRANCH CIRCUITS FROM PANEL '21C1', UNLESS OTHERWISE NOTED.

    G. ALL BRANCH CIRCUITING SHALL BE #10AWG., UNLESS OTHERWISENOTED.

    H. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE ON SHEETE702 FOR ADDITIONAL INFORMATION.

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    MECHANICAL EQUIPMENTPLATFORM

    A201

    GYM

    A111

    CAFETERIA

    A103

    MECHANICAL EQUIPMENTPLATFORM

    A200

    1 2 4

    B

    6.2 6.8

    B.3

    B.7

    D.9

    G.1

    H.2

    A

    3

    5

    2

    1

    4

    6

    A

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :27:0

    5 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    SE

    CT

    OR

    A P

    OW

    ER

    PLA

    N -

    SE

    CO

    ND

    FLO

    OR

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E121

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

    1/8" = 1'-0"1 SECTOR A POWER PLAN - SECOND FLOOR

    NOTES:

    1. 8 INCH BY 2 INCH BASKET CABLE TRAY. INSTALL ADJACENT TO DUCTWORK.

    2. TWO (2) 2 INCH CONDUITS THROUGH DIVIDING WALL SOFFIT. COORDINATE ROUTINGWITH DUCTWORK.

    3. TWO (2) 2 INCH CONDUITS DOWN TO AUDIO EQUIPMENT IN CABINETRY.

    4. TWO (2) CONDUITS TO AUDIO EQUIPMENT RACK.

    5. 8 INCH BY 2 INCH BASKET CABLE TRAY.

    6. APPROXIMATE LOCATION OF AUDIO EQUIPMENT RACK BELOW.

    GENERAL NOTES:

    A. REFERENCE SHEETS E013 AND E014 FOR UNDERGROUND CONDUITS FORFEEDERS AND DATA CABLING.

    B. AREA ABOVE ALL ELECTRICAL PANELS AND SWITCH BOARDS SHALL BEKEPT CLEAR OF ALL EQUIPMENT FOREIGN TO THE ELECTRICALINSTALLATION INCLUDING PIPING, DUCTWORK, SUPPORTS, ETC.COORDINATE INSTALLATION WITH ALL OTHER TRADES.

    C. ALL PENETRATIONS AND ROUTING PATHS OF EXPOSED CONDUIT SHALLBE COORDINATED AND REVIEWED BY ARCHITECT AND ENGINEER PRIOR TOINSTALLATION.

    D. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT,SHARED NEUTRALS ARE NOT PERMITTED.

    E. PROVIDE NO MORE THAN (6) CURRENT CARRYING CONDUCTORS PERHOMERUN.

    NO

    RT

    H

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    JJ

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    J

    JJ

    J

    JJ

    JJ J

    MULTIPURPOSE

    B226

    CLASSROOM

    B227

    CLASSROOM

    B229

    CLASSROOM

    B231

    BOYS

    B222

    GIRLS

    B223

    SMALL GROUP

    B216

    COMMONS

    B230

    CLASSROOM

    B244

    CLASSROOM

    B246

    CLASSROOM

    B248

    MULTIPURPOSE

    B249

    CLASSROOM

    B250

    COMMONS

    B245

    BOYS

    C205

    BOYS

    B241

    GIRLS

    B242

    WORKROOM

    B218

    IDF

    B238

    OFFICE

    B236

    STAFF TOILET

    B221

    SOR

    B220

    HALLWAY

    B219

    HALLWAY

    B217

    HALLWAY

    B224

    HALLWAY

    B228

    HALLWAY

    B232

    HALLWAY

    B235

    HALLWAY

    B237

    HALLWAY

    B247

    STAFF TOILET

    B240

    SOR

    B239

    HALLWAY

    C200

    OFFICE

    B234

    STAIR

    B151

    STAIR

    B128A

    MEDIA CENTER

    B132

    CLASSROOM

    B225

    PANEL 22A1

    PANEL 42A1

    PANEL 42LSA1

    PANEL 22B1

    GFCI GFCI GFCI

    GFCI GFCI

    GFCI

    GFCI

    GFCIGFCI

    GFCI

    /1

    E125

    PANEL IDF-1

    12"x4" BOCT: 9' - 6"

    12"x4" BOCT: 9' - 6"

    GFCIGFCI

    1

    GFCI

    GFCI

    GFCI

    2

    H

    8 9 10 12 13 14 15

    N

    S

    L

    C

    R

    Q

    M

    E

    F

    G

    D

    6.8 8.2 11

    F.2

    J

    K

    P

    P.7

    13.6

    E.7

    7.8

    11.9

    4

    +96" AFF3

    4

    +96" AFF 3

    +96" AFF

    4

    3

    4

    +96" AFF 3

    4

    +96" AFF3

    4

    +96" AFF 3

    4+96" AFF3

    4

    4

    +96" AFF 3

    4

    38.

    38.

    38.

    38.

    31. 31.

    27.

    25.

    29.

    29.

    29.

    2.2. 4,6.

    5.3.1.

    15. 13.13.

    45.

    23.

    15.

    13.

    17.13.

    35.

    17.

    23.

    21.

    19.

    3.1.1.

    47.

    11.

    3.

    1.

    5.1.

    25.

    5.

    11.

    9.

    7.

    7

    6.4.

    4.

    13.2.

    49.

    6.2.

    2.

    12.

    10.

    8.

    4.

    2.18.

    24.

    22.

    20.

    16. 14.

    14.

    14.18.

    27.

    +96" AFF 3

    14.

    51.

    24.

    16.

    28. 26.

    30.

    34.

    32.

    36.

    26.

    26.30.

    +96" AFF 3

    26.

    36.

    53.

    28.

    6

    5

    4.2.2.

    12.47.

    4.

    2.

    6.2.6.

    12.

    10.

    8.

    39.

    16. 14.14.

    24.

    49.

    16.

    14.

    18.14.

    18.

    24.

    22.

    20.

    39.

    28.48.

    28.28.

    39.

    26.

    26. 26.

    30.30.

    37.

    27. 25.25.

    35.

    41.

    27.

    25.

    29.25.

    29.

    35.

    33.

    31.

    13.

    23.

    43.

    15.

    13.

    17.13.

    17.

    23.

    21.

    19.

    15. 13.

    37.

    5.3. 3.

    1.

    45.

    5.

    1.

    5.1.

    11.

    9.

    7.

    1.

    3.

    7

    GFCI

    26.

    88

    88

    8

    8

    888

    49.49.

    +72" AFF

    1112

    11

    12

    47.+72" AFF 47.

    51.51.+72" AFF

    11

    12

    53.53.+72" AFF

    11

    12

    11

    12

    45.+72" AFF45.

    47.47.

    +72" AFF

    1112

    49.49.+72" AFF

    11

    12

    11

    12

    45.+72" AFF 45.

    11

    12

    41.+72" AFF41.

    11

    12

    43.+72" AFF43.

    41.

    43.

    109

    33.

    35.

    39.

    37.

    44.

    46.

    36.

    38. 40.

    42.

    22C1:35.

    22C1:37.

    COPIER

    TP-10

    TP-06

    FCU-B-IDF

    13 11.

    13 13.

    1324.

    13

    23.13

    1324.

    1335. 1323. 45.13

    13 12.

    EF-TLT

    B

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :27:1

    1 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    SE

    CT

    OR

    B P

    OW

    ER

    PLA

    N -

    SE

    CO

    ND

    FLO

    OR

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E123

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

    1/8" = 1'-0"1 SECTOR B POWER PLAN - SECOND FLOOR

    NO

    RT

    H

    NOTES:

    1. PROVIDE (3) 4 INCH AND (2) 2 INCH CONDUITS FROM CABLE TRAY TOWORKROOM B218. CONDUITS TO BE STUBBED OUT ABOVE ACCESSIBLE CEILING.

    2. PROVIDE (3) 4 INCH AND (2) 2 INCH CONDUITS FROM CABLE TRAY TO IDF B238.CONDUITS TO BE STUBBED OUT NEAR CEILING.

    3. RECEPTACLE FOR SHORT THROW PROJECTOR.

    4. RECEPTACLE FOR TABLET CHARGING. RECEPTACLE TO BE INSTALLED INCABINETRY. COORDINATE EXACT LOCATION WITH ARCHITECT.

    5. ALL RECEPTACLES SHOWN IN THIS AREA SHALL BE PROVIDED WITH BRANCHCIRCUITS FROM PANEL '22A1', UNLESS OTHERWISE NOTED.

    6. ALL RECEPTACLES SHOWN IN THIS AREA SHALL BE PROVIDED WITH BRANCHCIRCUITS FROM PANEL '22B1', UNLESS OTHERWISE NOTED.

    7. (3) 4 INCH AND (2) 2 INCH SLEEVES FROM MDF BELOW.

    8. PROVIDE CONNECTION TO HAND DRYER.

    9. ALL RECEPTACLES IN IDF B238 SHALL BE PROVIDED WITH BRANCH CIRCUITSFROM PANEL 'IDF-1', UNLESS OTHERWISE NOTED.

    10. PROVIDE A NEMA L6-30 CENTER ABOVE THE IT RACK. COORDINATE EXACTLOCATION WITH IT CONSULTANT.

    11. RECEPTACLE TO SERVE VIDEO MONITOR.

    12. PROVIDE CONNECTION TO A/V EQUIPMENT LOCATED ABOVE CEILING.COORDINATE EXACT LOCATION WITH A/V DRAWINGS.

    13. RECEPTACLE FOR MONITOR SHALL BE MOUNTED AT 60" AFF, BELOWPROJECTOR RECEPTACLE.

    GENERAL NOTES:

    A. REFERENCE SHEETS E013 AND E014 FOR UNDERGROUND CONDUITS FORFEEDERS AND DATA CABLING.

    B. AREA ABOVE ALL ELECTRICAL PANELS AND SWITCH BOARDS SHALL BE KEPTCLEAR OF ALL EQUIPMENT FOREIGN TO THE ELECTRICAL INSTALLATIONINCLUDING PIPING, DUCTWORK, SUPPORTS, ETC. COORDINATE INSTALLATIONWITH ALL OTHER TRADES.

    C. ALL PENETRATIONS AND ROUTING PATHS OF EXPOSED CONDUIT SHALL BECOORDINATED AND REVIEWED BY ARCHITECT AND ENGINEER PRIOR TOINSTALLATION.

    D. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT,SHARED NEUTRALS ARE NOT PERMITTED.

    E. PROVIDE NO MORE THAN (6) CURRENT CARRYING CONDUCTORS PERHOMERUN.

    F. ALL BRANCH CIRCUITING SHALL BE #10AWG., UNLESS OTHERWISE NOTED.

    G. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE ON SHEET E702FOR ADDITIONAL INFORMATION.

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    J

    JJ

    J

    J

    JJ J

    JJ

    CUST

    C201

    CLASSROOM

    C209

    CLASSROOM

    C207

    CLASSROOM

    C213

    MULTIPURPOSE

    C212

    CLASSROOM

    C211

    COMMONS

    C208

    BOYS

    C205

    GIRLS

    C204

    HALLWAY

    C200

    HALLWAY

    C206

    HALLWAY

    C210

    STAFF TOILET

    C203

    SOR

    C202

    HALLWAY

    C200

    STAIR

    C114

    PANEL 42C1

    PANEL 42LSC1

    PANEL 22C1

    GFCI

    GFCI GFCI

    GFCI

    GFCI

    GFCI

    /1

    E123

    GFCI

    GFCIGFCI

    1

    1

    3 5 6

    N

    S

    L

    R

    Q

    M

    K

    P

    4.3

    P.7

    0.9 6.1

    3

    2 +96" AFF

    3

    2+96" AFF

    3

    2+96" AFF

    3

    2 +96" AFF

    1.

    11.

    45.

    3.

    1.

    1.5.

    25.

    3.

    7.

    9.

    11.

    5.1.

    15.

    13.

    13.

    23.

    43.

    15.

    13.

    17.17.

    13.

    25.

    23.

    21.

    19.

    27.

    29.

    25.

    29.

    29.

    6. 47.2.

    4.

    47.

    2.

    12.

    4. 6. 4.

    4.

    12.

    10.

    8.

    3

    18.

    24.

    22.

    20.

    14.18.

    27.

    14.

    16.

    49.

    24.

    14.16.14.

    2 +96" AFF

    30.

    36.

    34.

    32.

    28.26.

    28.

    51.

    36.

    26.

    26.

    30.26.

    7

    4

    5.41.9

    5 5

    5

    26.

    51.51.

    +72" AFF

    67

    47. +72" AFF

    6

    7

    49.49.

    +72" AFF

    67

    6

    7

    43.+72" AFF 43.

    6

    7

    45.+72" AFF45.

    41.

    39.

    31.

    33.

    TP-09

    88

    8 8 8

    23.11.

    12.

    24. 36.

    12"x4" BOCT: 9' - 6"

    C

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :27:1

    6 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    SE

    CT

    OR

    C P

    OW

    ER

    PLA

    N -

    SE

    CO

    ND

    FLO

    OR

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E125

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

    1/8" = 1'-0"1 SECTOR C POWER PLAN - SECOND FLOOR

    NO

    RT

    H

    NOTES:

    1. PROVIDE (3) 4 INCH AND (2) 2 INCH CONDUITS FROM CABLE TRAY TO CUST C201.CONDUITS TO BE STUBBED OUT NEAR CEILING.

    2. RECEPTACLE FOR SHORT THROW PROJECTOR.

    3. RECEPTACLE FOR TABLET CHARGING. RECEPTACLE TO BE INSTALLED INCABINETRY. COORDINATE EXACT LOCATION WITH ARCHITECT.

    4. PROVIDE CONNECTION TO FIRE/SMOKE DAMPER.

    5. PROVIDE CONNECTION TO HAND DRYER.

    6. RECEPTACLE TO SERVE VIDEO MONITOR.

    7. PROVIDE CONNECTION TO A/V EQUIPMENT LOCATED ABOVE CEILING.COORDINATE EXACT LOCATION WITH A/V DRAWINGS.

    8. RECEPTACLE FOR MONITOR SHALL BE MOUNTED AT 60" AFF, BELOW PROJECTORRECEPTACLE.

    GENERAL NOTES:

    A. REFERENCE SHEETS E013 AND E014 FOR UNDERGROUND CONDUITS FOR FEEDERSAND DATA CABLING.

    B. AREA ABOVE ALL ELECTRICAL PANELS AND SWITCH BOARDS SHALL BE KEPT CLEAROF ALL EQUIPMENT FOREIGN TO THE ELECTRICAL INSTALLATION INCLUDING PIPING,DUCTWORK, SUPPORTS, ETC. COORDINATE INSTALLATION WITH ALL OTHER TRADES.

    C. ALL PENETRATIONS AND ROUTING PATHS OF EXPOSED CONDUIT SHALL BECOORDINATED AND REVIEWED BY ARCHITECT AND ENGINEER PRIOR TO INSTALLATION.

    D. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT, SHAREDNEUTRALS ARE NOT PERMITTED.

    E. PROVIDE NO MORE THAN (6) CURRENT CARRYING CONDUCTORS PER HOMERUN.

    F. ALL RECEPTACLES SHOWN ON THIS SHEET SHALL BE PROVIDED WITH BRANCHCIRCUITS FROM PANEL '22C1', UNLESS OTHERWISE NOTED.

    G. ALL BRANCH CIRCUITING SHALL BE #10AWG., UNLESS OTHERWISE NOTED.

    H. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE ON SHEET E702 FORADDITIONAL INFORMATION.

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    CAFETERIA

    A103

    A BEXIT

    ENTRY

    EXIT

    TRAYRETURN

    ENTRY

    CAFETERIA

    A103

    A BEXIT

    ENTRY

    EXIT

    TRAYRETURN

    ENTRYF

    F

    F

    F

    F

    F

    FF

    FF

    F

    F

    P

    F

    F

    F

    F F

    F

    F F

    F

    F

    F

    FS TS

    F

    VESTIBULE

    A100

    BOILER

    A119

    BLDG STORAGE

    A117

    COMMUNITY ROOM

    A102

    PE OFC/STG

    A114

    CUSTODIAL

    A116

    ELEC

    A118

    BOYS

    A109

    GIRLS

    A110

    FAMILY TOILET

    A107

    TBL STORAGE

    A105

    GYM

    A111

    MUSIC ROOM / STAGE

    A113

    LOBBY

    A101

    LOST AND FOUND

    A115

    CUST

    A104C

    CAFETERIA

    A103

    KITCHEN

    A104

    PE CIRCULATION

    A106

    CUST

    A112

    KITCHEN

    A104D

    RAMP

    A121

    HALL

    A106B

    WF

    A120

    KDU

    FACP

    /1

    E133

    /1 E135

    H

    1 2 4

    G

    D

    B

    6.2 6.8

    B.3

    B.7B.8

    D.9

    F.2

    G.1

    H.2

    B.5

    A

    121LSD1: 4.

    A

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :27:1

    9 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    SE

    CT

    OR

    A F

    IRE

    ALA

    RM

    PLA

    N -

    FIR

    ST

    FLO

    OR

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E131

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

    1/8" = 1'-0"1 SECTOR A FIRE ALARM PLAN - FIRST FLOOR

    NO

    RT

    H

    NOTES:

    1. COORDINATE QUANTITY AND LOCATION OF FIRE SPRINKLER FLOW AND TAMPERSWITCHES WITH FIRE SPRINKLER CONTRACTOR.

    GENERAL NOTES:

    A. THE FIRE ALARM SYSTEM IS A CONTRACTOR DESIGN-BUILD SYSTEM. DEVICELOCATIONS AND QUANTITIES SHOWN ARE PREFERRED; HOWEVER, ADDITIONALDEVICES MAY BE REQUIRED TO COMPLY WITH CODE. CONTRACTOR SHALLPROVIDE ADDITIONAL FIRE ALARM DEVICES, ACCESSORIES AND ANY ADDITIONALITEMS REQUIRED FOR A COMPLETE AND OPERATIONAL CODE COMPLIANTSYSTEM. REFERENCE SPECIFICATION DIVISION 28 30 00 FOR ADDITIONALINFORMATION.

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    F

    F

    F F

    F

    FF

    F

    F FF

    F

    F

    F

    F

    F

    F

    F

    F

    F

    F

    F

    FF

    F

    F

    F

    F

    F

    F

    F

    F

    F

    P

    F F

    F

    F F

    F F F

    P

    P

    F

    P

    P

    F

    F

    F

    F

    F

    CLASSROOM

    B127

    CLASSROOM

    B126

    COMMONS

    B130

    CLASSROOM

    B129

    CLASSROOM

    B131

    LIFE SKILLS

    B125

    RECEPTION

    B100

    CLASSROOM

    B146

    COMMONS

    B145

    MULTIPURPOSE

    B149

    CLASSROOM

    B148

    CLASSROOM

    B150

    CLASSROOM

    B144

    GIRLS

    B142

    TOILET

    B112

    GIRLS

    B123

    MDF

    B120

    HALLWAY

    B128

    TOILET

    B104

    BOYS

    B141

    PRINCIPAL

    B102

    CONFERENCE

    B110

    SECRETARY

    B101

    QUIET

    B105

    CLOSET

    B109

    VOLUNTEER

    B117

    SENSORY ROOM

    B115

    LACTATION RM

    B111

    HEALTH

    B106

    OFFICE

    B107

    CUST

    B138

    STAFF TOILET

    B140

    SMALL GROUP

    B134

    OFFICE

    B136

    BOYS

    C105

    SMALL GROUP

    B116

    MOTOR SKILLS

    B114

    WORKROOM

    B113

    HEALTH TOILET

    B108

    BOYS

    B122

    SOR

    B139

    STAFF ROOM

    B103

    HALLWAY

    B119

    ELEVATOR

    B118

    HALLWAY

    B124

    CHANGING TOILET

    B125C

    MEDIA CENTER

    B132

    MEDIA WORK RM

    B133

    STAIR

    B132B

    STAIR

    B132A

    HALLWAY

    B143

    HALLWAY

    B147

    SOR

    B121

    CHANGING

    B125D

    HALLWAY

    B137

    STAIR

    B151

    STAIR

    B128A

    HALLWAY

    B137

    STORY COVE

    B135

    3

    E501

    KDU

    /1

    E135

    /1 E135

    /1

    E131

    /1 E131

    H

    8 9 10 12 13 14 15

    N

    S

    L

    C

    R

    Q

    M

    E

    F

    G

    D

    6.8 8.2 11

    B.8

    F.2

    J

    K

    P

    P.7

    13.6

    E.7

    7.8

    11.9

    c c c

    cc

    c c

    c c c

    B

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :27:2

    4 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    SE

    CT

    OR

    B F

    IRE

    ALA

    RM

    PLA

    N -

    FIR

    ST

    FLO

    OR

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E133

    AM

    T

    SJT

    700 H

    OW

    AR

    D A

    VE

    , E

    UG

    EN

    E, O

    RE

    GO

    N 9

    7404

    1/8" = 1'-0"1 SECTOR B FIRE ALARM PLAN - FIRST FLOOR

    NO

    RT

    H

    GENERAL NOTES:

    A. THE FIRE ALARM SYSTEM IS A CONTRACTOR DESIGN-BUILD SYSTEM. DEVICELOCATIONS AND QUANTITIES SHOWN ARE PREFERRED; HOWEVER, ADDITIONALDEVICES MAY BE REQUIRED TO COMPLY WITH CODE. CONTRACTOR SHALLPROVIDE ADDITIONAL FIRE ALARM DEVICES, ACCESSORIES AND ANY ADDITIONALITEMS REQUIRED FOR A COMPLETE AND OPERATIONAL CODE COMPLIANTSYSTEM. REFERENCE SPECIFICATION DIVISION 28 30 00 FOR ADDITIONALINFORMATION.

  • 12-31-14EXPIRES

    REGIS

    TERED P

    ANISSE

    FOR

    LOIG

    N

    E

    N EE

    R

    Ju ly9991,3

    44775

    OREGON

    1

    GRA

    NT

    R. ARTHE

    MER

    P

    F

    F

    F

    F

    F

    F

    F

    F

    F

    F

    F

    FF

    P P

    CLASSROOM

    C113

    MULTIPURPOSE

    C112

    CLASSROOM

    C111

    CLASSROOM

    C109

    COMMONS

    C108

    CLASSROOM

    C107

    GIRLS

    C104

    IDF

    C101

    STAFF TOILET

    C103

    BOYS

    C105

    SOR

    C102

    HALLWAY

    C100

    HALLWAY

    C106

    HALLWAY

    C110

    STAIR

    C114

    /1

    E133

    1

    3 5 6

    N

    S

    L

    R

    Q

    M

    K

    P

    4.3

    P.7

    0.9 6.15.41.9

    c c

    ccc

    C

    RE

    VIS

    ION

    S:

    CH

    EC

    KE

    D:

    PR

    OJE

    CT

    #:

    ISS

    UE

    DA

    TE

    :

    DR

    AW

    N:

    PR

    INT

    ED

    O

    N:

    2014 P

    IVO

    T A

    RC

    HIT

    EC

    TU

    RE

    FR

    OM

    FIL

    E:

    C

    9/1

    2/2

    014 3

    :27:2

    7 P

    MC

    :\R

    evit L

    ocal F

    iles\1

    3-1

    532_H

    ES

    ME

    P14\1

    3-1

    532_H

    ES

    ME

    P14_sta

    cy.h

    ansen.r

    vt

    SE

    CT

    OR

    C F

    IRE

    ALA

    RM

    PLA

    N -

    FIR

    ST

    FLO

    OR

    EU

    GE

    NE

    SC

    HO

    OL D

    IST

    RIC

    T

    BU

    ILD

    ING

    AN

    D S

    ITE

    CO

    NS

    TR

    UC

    TIO

    N D

    OC

    UM

    EN

    TS

    HO

    WA

    RD

    ELE

    ME

    NT

    AR

    Y S

    CH

    OO

    L

    13

    36

    09

    /23

    /20

    14

    E135

    AM

    T

    SJT

    70


Recommended