Access Modular Controller 2 APC‑AMC2‑4R4CF | ADS‑AMC2‑4R4CF en Installation manual
Transcript
Page 1: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2APC‑AMC2‑4R4CF | ADS‑AMC2‑4R4CF

en Installation manual

Page 2: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01
Page 3: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Table of contents | en 3

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Table of contents1 Safety Instructions 51.1 Important safety notes 51.2 Safety precautions 61.3 Unpacking 72 Important Information 82.1 Explanation of symbols in this document 82.2 Internet 83 Introduction 93.1 Description 93.1.1 Extension AMC2-16IOE 143.1.2 Extension AMC2-8IOE 153.1.3 Extension AMC2-16IE 163.2 Equipment Configuration 163.3 Performance Characteristics 263.4 System Overview 274 Installing 334.1 Mounting 334.2 Unmounting 344.3 Opening the Case 364.4 Closing the Case 394.5 Cabling 404.5.1 Conductor data for power to AMC2 404.6 Grounding and Shielding 424.6.1 Grounding for Host Interface 434.6.2 Grounding for Extension Interface 444.6.3 Grounding for Bus Interfaces 454.7 Connecting Power Supply 464.7.1 Direct Power Supply 474.7.2 Power Supply via RS-485 Interface 484.7.3 Overview - Power supply/consumption 494.8 Ethernet Host Interface 534.9 RS-485 Host Interface 554.9.1 RS-485 Two Wire Connection 574.9.2 RS-485 Four Wire Connection 584.10 RS-232 Host Interface 604.11 DIL switch selector 614.11.1 Host settings 624.11.2 Setting the host 634.11.3 Board Settings 644.12 RS-485 for extension modules 654.12.1 Addressing 684.13 Wiegand Interface for Card Readers 694.13.1 Connecting different reader types 704.14 RS-485 Interface for Card Readers 724.15 RS-232 Interface for Card Readers 734.16 Connecting Relay Outputs 754.17 Connecting Analog Input Devices 824.18 Tamper Protection 87

Page 4: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

4 en | Table of contents Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

5 Operating 905.1 Status Display of the AMC2 905.2 Configuring the Ethernet Interface 925.3 Troubleshooting 945.3.1 Resetting the Software 945.3.2 Resetting the Device to Factory Default 966 Technical Data 977 Appendices 1027.1 Connecting Diagrams 102

Index 120

Page 5: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Safety Instructions | en 5

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

1 Safety InstructionsNotice!To build an UL approved system refer the documentation contained in the folder titled "_UL"on the delivered CD.

1.1 Important safety notes1. Read, follow, and retain instructions - All safety and operating instructions must be read

and followed properly before putting the unit into operation. Retain instructions forfuture reference.

2. Do not ignore warnings - Adhere to all warnings on the unit and in the operatinginstructions.

3. Accessories - Use only accessories recommended by the manufacturer or those sold withthe product. Accessories not recommended by the manufacturer must not be used, asthey may cause hazards.

4. Installation precautions - Do not place this unit on an unstable stand, tripod, bracket, ormount. The unit may fall, causing serious injury to persons and damage to the unit. Mountthe unit according to the manufacturer’s instructions.

5. Service - Do not attempt to service this unit by yourself. Opening or removing covers mayexpose you to dangerous voltages or other hazards. Refer all servicing to qualified servicepersonnel.

6. Damage which requires service - Disconnect the unit from the main AC or DC powersource and refer servicing to qualified service personnel under the following conditions:– If the power supply cord or plug is damaged.– If liquid has been spilled or an object has fallen into the unit.– If the unit has been exposed to water and/or inclement weather (rain, snow, etc.).– If the unit does not operate normally when following the operating instructions.

Adjust only those controls specified in the operating instructions. Improperadjustment of other controls may result in damage, and require extensive work by aqualified technician to restore the unit to normal operation.

– If the unit has been dropped or the cabinet damaged.– If the unit exhibits a distinct change in performance.

7. Replacement parts - If replacement parts are required, the service technician must useonly replacement parts that are specified by the manufacturer. Unauthorizedreplacements may result in fire, electrical shock or other hazards.

8. Safety check - Upon completion of service or repair work on the unit, ask the servicetechnician to perform safety checks to ensure that the unit operates properly

9. Power sources - Operate the unit only from the type of power source indicated on thelabel. If unsure of the type of power supply to use, contact your dealer

10. Lightning - For added protection during electrical storms external lightning conductorscan be installed. This prevents power surges from damaging the unit.

11. The units should be installed in locations with restricted access.

Page 6: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

6 en | Safety Instructions Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

1.2 Safety precautionsRead the instructionsBefore working with the AMC2 device, read these instructions carefully. Make sure you haveunderstood all information described in this document.

!

Warning!Risk of electric shockExternal power supplies must be installed and put into service by qualified personnel.Ensure compliance with the relevant regulations.Ground the controller.Disconnect both AC and battery power supply before working on the controller.

!

Warning!Risk of fireInstallation of the AMC2 device must comply with any local fire, health, and safetyregulations. A secured door that may be part of an escape route from an area must beinstalled with:Install a fail-safe lock (A), so that the door will be released if power fails. Ideally, use amagnetic lock.Install a normally-closed break glass or a manual pull (B) in the lock supply wiring, so that inan emergency the fail-safe lock can be immediately powered down.

!

Warning!Risk of explosion of Lithium batteryThe battery can explode if it is replaced incorrectly.Replace only with the same type as recommended by the manufacturer.Dispose used batteries according to the battery manufacturer’s instructions.

Notice!Risk of damage to equipmentProtect the hardware from electrostatic discharge by observing ESD instructions beforeunpacking of touching connectors of electronics.Always switch off power of the AMC2 device before modifying the installation.Do not connect or disconnect plug connectors, data cables, or screw connectors while poweris on.

Rules and ConditionsThere are no specific requirements as for selling and delivery. As for storage and safeoperation, the environmental temperature should not exceed the range of 0°C to 50°C.DisposalYour Bosch product is designed and manufactured with high-quality materials andcomponents which can be recycled and reused.

This symbol means that electrical and electronic equipment, at their end-of-life, should bedisposed of separately from your household waste.

Page 7: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Safety Instructions | en 7

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

In the European Union, there are separate collection systems for used electrical and electronicproducts. Please dispose of this equipment at your local community waste collection/recyclingcenter.

1.3 UnpackingCheck the packaging for visible damage. If anything has been damaged during transport,please inform the transport agency.Unpack the unit carefully. This is an electronic device that must be handled with care to avoiddamage. Do not attempt to put the unit into operation if components are damaged.If any parts are missing, inform your customer service representative or a Bosch SecuritySystems salesperson. The shipping carton is the safest transport container for the unit. Storeit and the other packaging material for future use. If the unit has to be sent back, use theoriginal packaging.

Page 8: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

8 en | Important Information Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

2 Important InformationRemarksThis hardware is part of a security system. Access should be limited to authorized personsonly.Some states do not allow the exclusion or limitation of implied warranties, or limitation ofliability for incidental or consequential damages, hence the above limitation or exclusion mightnot apply to you.Bosch Security Systems retains all rights not expressly granted. Nothing in this licenseconstitutes a waiver of Bosch’s rights under the U.S. Copyright laws or any other federal orstate law.If you have any questions concerning this license, please, write to:

Bosch Sicherheitssysteme GmbHRobert-Bosch-Ring 585630 GrasbrunnGermany.

2.1 Explanation of symbols in this documentThroughout this document, warning messages, important notes, and helpful tips are presentedfor the reader. These appear as follows:

Danger!Cause of HazardIndicates a hazardous situation, which, if not avoided, will result in death or serious injury.

!

Warning!Cause of HazardIndicates a hazardous situation, which, if not avoided, could result in death or serious injury.

!

Caution!Cause of HazardIndicates a hazardous situation, which, if not avoided, could result in minor or moderateinjury.

Notice!Cause of HazardImportant Notes that must be followed to avoid damage to the equipment or environment,and to ensure successful operation and programming. Tips and shortcuts may also be included in such notes.

2.2 InternetIf you are interested in further information on this product or information on other products,please consult our website at http://www.boschsecurity.com.

Page 9: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Introduction | en 9

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

3 Introduction3.1 Description

The APC-AMC2-4R4CF (also called AMC2-4R4, AMC2, or controller) is equipped with fourindependent interfaces for RS-485 type readers. It is able to control up to four doors with areader in each direction and up to eight doors with a reader in one direction only.The APC-AMC2-4WCF (also called AMC2-4W , AMC2, or controller) is equipped with fourindependent interfaces for Wiegand type readers. It is able to control two doors with a readerin each direction and up to four doors with a reader in one direction only.The extension module AMC2-4WE is equipped with four Wiegand type reader-interfaces pluseight inputs and eight outputs. Hence with the AMC2-4WE it is possible to double the numberof readers on an AMC2-4W from 4 to 8.The AMC2-16ION board provides inputs and outputs to control doors and other componentsindependent of access control system.The extension board AMC2-16IOE can be used with an AMC2 controller. It serves additionalinputs and outputs.The AMC2-4R4 (also called AMC2 or controller) access control unit provides complete accesscontrol for a single entrance. Two card readers (or keyboard card readers) can be connectedand controlled via the two Wiegand interfaces plus up to two readers via the RS-485 interfaceand one via the RS-232 interface.The RS-232 interface here is not used for simple access control readers, but rather forsupplementary identification methods such as biometric (finger print, iris scan) scanners orlong-range readers.

Figure 3.1: The Access Modular Controller AMC2-DCUA

Figure 3.2: The Access Modular Controller AMC2-2R2

Page 10: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

10 en | Introduction Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 3.3: The Access Modular Controller AMC2-4W

Figure 3.4: The Access Modular Controller AMC2-4R4

Figure 3.5: The extension module AMC2-4WE

Figure 3.6: The IO-Controller AMC2-16ION

Page 11: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Introduction | en 11

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Figure 3.7: The extension board AMC2-16IOE

All necessary information for access verification is stored in a battery buffered on-boardmemory and a Compact Flash (CF) memory card. This guarantees autonomous accessdecisions and complete access registrations even if the management host system is offline.The built in compact flash card provides adequate storage capability for cardholders andevents.

The AMC2-4R4 electronics are completely covered by a plastic housing. The liquid crystaldisplay provides all important status information.

All necessary information for access verification is stored in a battery buffered on-boardmemory and a Compact Flash (CF) memory card. This guarantees autonomous accessdecisions and complete access registrations even if the management host system is offline.The built in compact flash card provides adequate storage capability for cardholders andevents.

The AMC2-4W electronics are completely covered by a plastic housing. The liquid crystaldisplay provides all important status information.

Using the AMC2-4R4 gives you the full functionality and the offline capability of a completeaccess control system in each room. This leads to an excellent reliability and a very highredundancy without extra cost.The AMC2-4WE can not be deployed as an independent controller but only as an extensionmodule for the AMC2-4W. Control and access decisions and bookings are carried out by theAMC2-4W alone.

Notice!The AMC2-4WE can only be used with AMC2-4W. As it provides Wiegand interfaces it cannotbe coupled with an AMC2-4R4.

The AMC2-4W can be extended by a maximum of one AMC2-4WE plus a maximum of three I/Oextension modules. The I/O extension modules AMC2-8IOEAMC2-16IOE (in any combination)are, like the AMC2-4WE, connected via the AMC2-4W’s extension interface.

Page 12: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

12 en | Introduction Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Notice!The AMC2-4WE has no display. The information about the input and outputs will be shown onspecial pages of the AMC2 display.

As the extension modules contain neither memory nor display they are controlled andmonitored entirely by the AMC2-4W.The AMC2-4W can have an additional interface extension module AMC2-4WE, so that thenumber of inputs and outputs can grow up to 64.

Notice!An AMC2-4WE provides signals only to the AMC2 to which it is connected. Signal transfer toanother AMC2 is not possible.

The signal settings and parametrization of the readers connected to the extension module, arecarried out by the configuration applications in the access control system and by theAMC2-4W to which it belongs.The AMC2-4R4 standalone board (hereafter also referred as AMC2 or controller) are deployedvia a dedicated OPC-Server. Though similar in appearance to the AMC2-4W and AMC2-4R4controllers, the AMC2-4R4 has no reader interfaces, but is intended instead for the efficientmonitoring and control of many devices, especially entrances, simultaneously. It is not anextension board like the AMC2-16IOE, AMC2-8IOE, and AMC2-16IE but possesses its own CPUand host interfaces.The AMC2-4R4 has 16 analog inputs and 16 relay outputs. Via its inputs the module candetermine the status (e.g. locked, closed or open) of entrances, windows or other devices,and its output signals can lock/unlock doors, or trigger alarms with external monitoringsystems in the case of an intrusion.If the 8 and the 8 outputs are insufficient for your needs, then up to three extensions(AMC2-16IOE , AMC2-8IOE, or AMC2-16IE) can be connected, thus providing the AMC2-4R4with a maximum of 64 inputs and 64 outputs for configuration.The AMC2 has eight analog input devices and eight relay outputs. With its analog inputdevices, the AMC2 verifies, for example, if a lock is closed or open. The relay outputs can beused to activate lock mechanisms if access is granted, or activate an external alarm system ifan intrusion or system alert is detected.If the eight inputs and eight outputs of the AMC2 are not enough to configure the system up tothree additional extensions AMC2-16IOE can be connected. The extension offers 16 additionalinputs and outputs.The AMC2-16IOE electronic is completely covered by a plastic housing.

Notice!The AMC2-16IOE has no display. The information about the input and outputs will be shownon special pages of the AMC2 display.

The AMC2-16IOE contains 16 analog inputs and 16 relay outputs. In analogy with the AMC2 itverifies if a lock is open or closed respectively activates alarms or lock mechanisms.An AMC2-4W can have an additional interface extension module AMC2-4WE, so that thenumber of inputs and outputs grow up to 64.

Page 13: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Introduction | en 13

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Notice!An AMC2-16IOE provides signals only to the AMC2 to which it is connected. Signal transfer toanother AMC2 is not possible.

Figure 3.8: The AMC2-4W in a four door safety lock

Figure 3.9: The AMC2-4R4 in a four door safety lock

Figure 3.10: Example of an entrance configuration with an AMC2-2R2

The AMC2-4R4 communicates with the host system primarily by ethernet. In specialconfigurations the RS-485 interface can also be used for the host connection.

Page 14: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

14 en | Introduction Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Notice!The RS-485 interface can be used either for the host connection or to connect extensionboards. If extension boards are used then the host connection must be by ethernet.

The AMC2-4R4 possesses six analog inputs and six relay outputs. It receives state informationabout the entrance via the inputs and transmits door control signals and/or notifications toexternal monitoring systems via the outputs. If the six inputs and six outputs of the AMC2-4R4are not sufficient then up to 3 extensions (AMC2-8IOE, AMC2-16IOE or AMC2-16IE) with 8 or16 inputs and outputs respectively can be connected.

Notice!This controller is currently a project version.

The allocation of the signals is determined by "door models" which, when selected, reservethe necessary reader connections and contacts for their usage. This default allocation can beoverriden and adapted to circumstances using the parameterization tools in the access controlsystem, where any free contact can have a signal allocated.

The AMC2-4R4 can communicate upstream to the host computer using RS-485 multi‑dropped,RS-232 or 10/100 Mbit/s Ethernet. It has eight analog input devices and eight relay outputs.With its analog input devices, the AMC2-4R4 verifies, for example, if a lock is closed or open.The relay outputs can be used to activate lock mechanisms if access is granted, or activate theburglar alarm system if an intrusion or system alert is detected. If the eight inputs and eightoutputs on board are not enough to configure the system, up to three additional extensions(AMC2-8IOE, AMC2-16IE, or AMC2-16IOE) can be connected. The extensions offer 8 or 16additional inputs and outputs.The setup procedure for an AMC2-4R4 is made very simple and fast by the use of doortemplates. Once selected, all the inputs and outputs are predefined. These settings can bechanged to choose every free contact of the controller or a connected extension.

3.1.1 Extension AMC2-16IOEThe extension board AMC2-16IOE can be used with an AMC2 controller. It serves additionalinputs and outputs.

Figure 3.11: The extension board AMC2-16IOE

Page 15: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Introduction | en 15

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

The AMC2 has eight analog input devices and eight relay outputs. With its analog inputdevices, the AMC2 verifies, for example, if a lock is closed or open. The relay outputs can beused to activate lock mechanisms if access is granted, or activate an external alarm system ifan intrusion or system alert is detected.The AMC2-16IOE electronics are completely covered by a plastic housing.

Notice!The AMC2-16IOE has no display. The information about the input and outputs will be shownon special pages of the AMC2 display.

Notice!An AMC2-16IOE provides signals only to the AMC2 to which it is connected. Signal transfer toanother AMC2 is not possible.

Notice!Depending on the software system up to 3 extension modules can be connected at random.

3.1.2 Extension AMC2-8IOETo optimize the utilization of the available signals the extension module can be delivered in areduced version, too. The AMC2-8IOE has eight inputs and eight outputs. The places of thepluggable screw connectors are on one side of the module - the other side will be closed bythe housing.

Figure 3.12: Extension module AMC2 8IOE

Notice!The AMC2-8IOE is identical in all respects to the AMC2-16IOE except in the number of inputsand outputs. Information in this manual refers to all three extensions described here, unlessexplicitly stated otherwise.

Page 16: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

16 en | Introduction Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

3.1.3 Extension AMC2-16IEAnother variant of the extension modul AMC2-16IOE is the AMC2-16IE which offers connectorsfor input signals only.The inputs are located at the same positions as on the AMC2-16IOE. The output connectionsin the AMC2-16IE are not usable. Within a system configuration the AMC2-16IE is treated as anormal extension module:It can be connected at any AMC2. Up to three extensions (for BIS three, for Access PE onlyone) can be connected to an AMC2. Extension variants can be used in any combination.

Figure 3.13: Extension module AMC2-16IE

Notice!The AMC2-16IE is identical in all respects to the AMC2-16IOE except in missing outputs.Information in this manual refers to all three extensions described here, unless explicitlystated otherwise.

3.2 Equipment Configuration

Figure 3.14: Upper circuit board with display (top side)

Page 17: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Introduction | en 17

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Figure 3.15: Upper circuit board with display (top side)

Figure 3.16: Upper circuit board with display (top side)

Figure 3.17: Circuit board with display (top side)

1 (N.A.)

2 DIL switch for RS-485 address selection , protocol, and RS-232/RS-485 selection.

3 Lithium battery for buffering of static RAM and real time clock (RTC). The battery lifeis estimated at 10 years, nevertheless an error message is generated if the voltagesinks below a preset minimum level.NOTICE: In order to avoid an error message caused by an earlier voltage drop wesuggest to replace the battery every 8 years. Spare part: VARTA CR 2032 PCB.

Page 18: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

18 en | Introduction Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

4 Reset push button - reachable through the casing using a screwdriver

5 Liquid Crystal Display

6 Push button, available on top of the housing, to select different display modes

7 Jumper: Equalization of potential between different systems and earth ground(shield)

8 Jumper: Interface selector RS-485 host connection, RS-485 two wire or RS-485 fourwire (depends on external wiring)

9 Configurable RS-485 host interface

10 Docking port for compact flash memory

11 Configurable RS-232 host interface (ribbon cable connector)

12 Configurable 10/100 Mbit/s Ethernet host interface

1. Internal tamper contact2. DIL switch for RS-485 address selection protocol3. Lithium battery for buffering of static RAM and real time clock (RTC). The battery life is

estimated at 10 years, nevertheless an error message is generated if the voltage sinksbelow a preset minimum level.

4. Reset push button - reachable through the casing using a screwdriver5. Liquid Crystal Display6. Push button, available on top of the housing, to select different display modes.7. Jumper: Equalization of potential between different systems and earth ground (shield)8. Jumper: Interface selector RS-485 Host connection, RS-485 two wire or RS-485 four wire

(depends on external wiring)9. Configurable RS-485host interface10. Docking port for compact flash memory11. Configurable RS-232 host interface (ribbon cable connector)12. Configurable 10/100 Mbit/s Ethernet interface

1 Jumper: Equalization of potential between different systems and earth ground(shield) using this interface to connect the host or extensions.

2 DIL switch for host settings.

3 Configurable 10/100 Mbit/s Ethernet interface

4 Docking port for micro SD memory card

5 Liquid Crystal Display

6 Jumper for setting either voltage free relay output (“dry” mode) or looped-in voltagefrom the AMC2-4R4 internal power supply (“wet” mode).

7 Push button, available on top of the housing to select different display modes.

8 Jumper: Potential equalization between different systems and earth ground (shield)for the bus systems.

Page 19: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Introduction | en 19

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

9 Reset push button - reachable through the casing using a screwdriver

Figure 3.18: Overview - Interfaces

Figure 3.19: Overview - Interfaces

Figure 3.20: Overview - Interfaces

Page 20: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

20 en | Introduction Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 3.21: Overview - Interfaces

Figure 3.22: Overview - Interfaces

Figure 3.23: Overview - Interfaces

13 RS-485 extension module bus

14 External tamper contact

15 Connector for power supply

16 RS-485 interfaces for up to 8 card readers

17 Connectors for eight analog inputs

Page 21: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Introduction | en 21

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

18 Connectors for eight relay outputs

13 RS-485 extension module bus

14 External tamper contact

15 Connector for power supply

16 Connectors for eight analog inputs

17 Connectors for eight relay outputs

4 RS-485 extension module bus

4 RS-485 extension module bus

4 External tamper contact

4 Internal tamper contact

4 Connector for power supply

4 interfaces for up to 8card readers

1. Connectors for eight analog inputs2. Connectors for eight relay outputs

1 RS-485 extension module bus

2 External tamper contact

3 Connector for power supply

4 Wiegand interfaces for up to 8card readers

5 Connectors for eight analog inputs

6 Connectors for eight relay outputs

1 RS-485 extension module bus

2 External tamper contact

3 N.A.

4 Connector for power supply

5 Connectors for 16 analog inputs

6 Connectors for 16 relay outputs

10 Configurable RS-485 host interface or extension interface

11 External tamper contact

12 RS-232 reader interface

13 Wiegand reader interfaces

14 Connectors for six analog inputs

15 Connectors for six relay outputs

16 RS-485 reader bus

Page 22: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

22 en | Introduction Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

17 Connector for power supply

Notice!All connectors, with the exception of the RS-232 and Ethernet host interface, are pluggablescrew clamp terminals.

Figure 3.24: Jumper at the bottom side

Figure 3.25: Jumper at the bottom side

Figure 3.26: Parts at the bottom side

Page 23: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Introduction | en 23

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Figure 3.27: Jumpers at the bottom side

Figure 3.28: Jumpers at the bottom side

Figure 3.29: Jumpers at the bottom side

19 Jumper for setting either voltage free relay output (“dry” mode) or looped-in voltagefrom the AMC2 internal power supply (“wet” mode).

20 Jumper: Potential equalization between different systems and earth ground (shield)for the bus systems.

21 Jumper: Equalization of potential between different systems and earth ground(shield) for the extension interface.

19 Jumper for setting either voltage free relay output (“dry” mode) or looped-in voltagefrom the AMC2 internal power supply (“wet” mode).

Page 24: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

24 en | Introduction Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

20 Jumper: Equalization of potential between different systems and earth ground(shield) for the extension interface.

18 Jumper for setting either voltage free relay output (“dry” mode) or looped-in voltagefrom the AMC2 internal power supply (“wet” mode).

19 DIL switch for setting the board address.

20 Jumper: Equalization of potential between different systems and earth ground(shield) for the extension interface.

7 Jumper for setting either voltage free relay output (“dry” mode) or looped-in voltagefrom the AMC2 internal power supply (“wet” mode).

8 Jumper: Equalization of potential between different systems and earth ground(shield) for the extension interface.

Page 25: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Introduction | en 25

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

7 Jumper for setting either voltage free relay output (“dry” mode) or looped-in voltagefrom the AMC2 internal power supply (“wet” mode).

8 DIL switch for setting the board address.

9 Jumper: Equalization of potential between different systems and earth ground(shield) for the extension interface.

4 Jumper for setting either voltage free relay output (“dry” mode) or looped-in voltage fromthe AMC2 internal power supply (“wet” mode).

4 Jumper: Potential equalization between different systems and earth ground (shield) forthe bus systems.

4 Jumper: Equalization of potential between different systems and earth ground (shield).

18 Lithium battery for buffering of static RAM and real time clock (RTC). The battery lifeis estimated at 10 years, nevertheless an error message is generated if the voltagesinks below a preset minimum level.NOTICE: In order to avoid an error message caused by an earlier voltage drop wesuggest to replace the battery every 8 years. Spare part: VARTA CR 2032 PCB.

Notice!For details on the setting of the jumpers and DIL switches listed here, please see DIL switchselector, page 61.

Page 26: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

26 en | Introduction Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

3.3 Performance Characteristics– Intelligent access manager for 1 - 8 entrances (for example doors, man traps, barriers)– Controlled by an AMC2 via RS-485– Host address selectable using DIL sliding switch.– Four possible configurable host interfaces:

– Ethernet (= standard)– RS-485 2-wire– RS-485 4-wire– RS-232

– Two possible configurable host interfaces:– Ethernet (= standard)– RS-485 2-wire

– Reader interfaces– Reader interfaces

– four two Wiegand interfaces– Reader interfaces

– two Wiegand interfaces– one RS-485 interface

– Reader interfaces– four RS-485 interfaces

– Reader interfaces– two RS-232 interfaces

– Slave interface– one RS-232 for additional control (biometrical or long distance reader)

– Eight relay outputs– voltage free, power is supplied externally (dry mode)– powered by internal power supply (wet mode)

– Eight analog inputs with internal power supply– 8 relay outputs

– voltage free, power is supplied externally (dry mode)– powered by internal power supply (wet mode)

– 8 analog inputs with internal power supply– Battery buffered SRAM and real time clock (RTC)– Pluggable Compact Flash card– Liquid Crystal Display– Transfer rate host interface RS-485: 38,4 kBit/s– Transfer rate host interface RS-232: 38,4 kBit/s– Transfer rate host interface Ethernet: 10/100 Mbit/s– Transfer rate to the extension interface: 9,6 kBit/s– Transfer rate reader interface RS-485: 9,6 kBit/s– Transfer rate reader interface depends on the connected device.– Self regulating transmit/receive switching– Supply voltage: 10 V to 14 Vdc,– Max current load: 3A– Power supply:

– 10V - 30Vdc - max. 3 A– or over the RS-485 host connector

– Information about the inputs and outputs on the display of the AMC2 controller– Tamper contact for external covers

Page 27: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Introduction | en 27

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

– If an external power supply is used then this should be an Altronix model AL600ULX withintegrated uninterruptable power supply (UPS).

Notice!If an external power supply is used, this should also guarantee an uninterruptable powersupply (UPS). Example: Bosch power supply APS-PSU-60 (F.01U.282.970).

3.4 System OverviewThe Access Controller AMC2-4R4 is connected between the management host system anddifferent peripheral devices. By default, a management host system is connected usingEthernet. A management host connection using RS-485 or RS-232 is also possible.Corresponding to the available interfaces, one AMC2 can be connected to each COM portusing RS-232 mode. In RS-485 mode, up to eight access controllers can be combined on oneparty line.The AMC2-4R4 is deployed as an independent controller between the management hostsystem and various peripheral devices. By default, a management host system is connected viaEthernet. A management host connection using RS-485 or RS-232 is also possible.The AMC2-4WE is connected between the access controller AMC2-4W and the variousperipheral devices.The extension module AMC2-16IOE is connected to the Access controller AMC2. By default itis connected via RS-485.

Figure 3.30: System overview

1 = Host

2 = AMC2-4R4

3 = Wiegand reader (1 - 4)

4 = Communication and power supply

5 = Ethernet

Page 28: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

28 en | Introduction Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 3.31: System overview

1 = Host

2 = AMC2-4R4

3 = Card reader (1 - 2)

4 = Communication and power supply

5 = Ethernet

Figure 3.32: System overview

1 = Host

2 = AMC2-4R4

3 = Card reader (1 - 8)

4 = Communication and power supply

5 = Ethernet

System configurations for Access Control applications– The minimum configuration consists of:

– one PC with system software,

Page 29: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Introduction | en 29

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

– one AMC2 controller,– one AMC power supply,– one AMC enclosure.

– The maximum configuration depends on the system software,– the necessary number of APS-PSU-60 power supplies,– the necessary number of AMC enclosures.

Figure 3.33: System overview

1 = Host

2 = Ethernet

3 = AMC2-4R4

4 = RS-232 connection (for special control functions)

5 = RS-485 connection for max. two readers

6 = Wiegand connection

Figure 3.34: System overview

1 = Host

2 = AMC2-4W

3 = Card reader

Page 30: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

30 en | Introduction Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

4 = Communication and power supply

5 = AMC2-4WE

Figure 3.35: System overview

1 = Host

2 = AMC2-Controller

3 = Card reader

4 = Communication and Power supply

5 = AMC2-Extension

6 = Ethernet

Figure 3.36: System overview

1 = Host

2 = Ethernet

3 = Access Controller

Page 31: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Introduction | en 31

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

a = AMC2-4W

b = AMC2-4R4

4 = AMC2-16ION

5 = I/O-Extensionboards

a = AMC2-16IOE

b = AMC2-8IOE

c = AMC2-16IE

6 = Card reader

7 = Communication and power supply

Depending on the kind of interface are available the following constellations are possible:– Using RS-232 host connection one AMC2-4R4 can be connected per COM port.– Using RS-485 host connection, up to eight of these modules can be combined on one

COM port.– Up to three extension boards can be connected to and controlled by the AMC2-4R4.

These can be any combination of types AMC2-8IOE, AMC2-16IOE, or AMC2-16IE.

System configurations for Access Control applications.– The minimum configuration consists of:

– one PC with system software,– one AMC2 controller,– one AMC power supply,– one AMC enclosure.

– The maximum configuration depends on the system software,– Each AMC2-4W controller can be extended with an AMC2-4WE extension module.Using an AMC-MUX interface extension on RS-485 host connections it is possible to connectup to eight controllers to a single COM port. Up to 200 AMCs can be connected using theethernet host connection.

Notice!If the host connection is via ethernet then the RS-485 interface can be used for extensionboards.

Using the reader interfaces, up to two RS-485 and two Wiegand peripheral devices can beconnected to each AMC2-4R4. The RS-232 interface can be used for additional input devicessuch as biometric readers or long-range readers. The RS-232 and Wiegand interfaces arepoint-to-point connections, meaning that only one reader can be connected to one interface.The using of AMC2-4WE modules has no influence on the limit of the maximum of controllersin one system, because it is an extension to an AMC2-4W and not a controller.Using Wiegand reader interfaces, up to four peripheral devices can be connected to eachAMC2-4R4. The interfaces are point-to-point connections, meaning that only one reader can beconnected to one interface.

Page 32: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

32 en | Introduction Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Using RS-485 reader interfaces, up to eight peripheral devices can be connected to eachAMC2. The four reader interfaces are divided into two buses. Interface 1 and 2 are on one bus,and interfaces 3 and 4 are on the other bus. With this arrangement, you can connect allreaders to one interface.The extension interface supports up to three additional I/O boards (AMC2-8IOE, AMC2-16IE,or AMC2-16IOE). All extension boards are controlled by the AMC2 and are freely combinable.

Notice!This controller is currently a project version.

Page 33: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 33

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

4 InstallingNotice!To build an UL approved system refer the documentation contained in the folder titled "_UL"on the delivered CD.

Notice!To build a UL listed configuration, refer to UL Requirements

4.1 MountingThe AMC2-4R4 can be attached on a standard 35 mm (1.377 in.) mounting rail using a snap-inmechanism. Attach the AMC2-4R4 into the upper edge of the mounting rail [1], then pushdown the device and snap it onto the rail by pushing it towards the back [2].The AMC2-4W can be attached on a standard 35 mm (1.377 in.) mounting rail using a snap-inmechanism. Attach the AMC2-4W into the upper edge of the mounting rail [1], then pushdown the device and snap it onto the rail by pushing it towards the back [2].

Figure 4.1: Mounting the AMC2 on a mounting rail

Figure 4.2: Mounting the AMC2 device on a mounting rail

Page 34: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

34 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

4.2 Unmounting

Notice!To remove the AMC2-4R4 from a mounting rail, first remove all pluggable connectors.

Push down the AMC2-4R4 until the lower edge snaps out of the mounting rail [1]. Pull thelower end of the AMC2-4R4 from the mounting rail [2].

Notice!To remove the AMC2-4W from a mounting rail, first remove all pluggable connectors.

Push down the AMC2-4W until the lower edge snaps out of the mounting rail [1]. Pull thelower end of the AMC2-4W from the mounting rail [2].

Figure 4.3: Unmounting the AMC2 from a mounting rail

Page 35: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 35

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Figure 4.4: Unmounting the AMC2 device from a mounting rail

Page 36: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

36 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

4.3 Opening the Case

Notice!To open the AMC2-4R4, first remove all pluggable connectors.

The AMC2-4R4 case consists of a top cover mounted with a two-point snap-in closure on achassis. To open the case, push down the two snap-ins with a screwdriver, then swing thecover down.

Notice!To open the AMC2-4W , first remove all pluggable connectors.

The AMC2-4W case consists of a top cover mounted with a two-point snap-in closure on achassis. To open the case, push down the two snap-ins with a screwdriver, then swing thecover down.

Figure 4.5: Opening the AMC2 case

Figure 4.6: Opening the AMC2-2R2 case

Page 37: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 37

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Figure 4.7: Opening the AMC2-DCUA case

Figure 4.8: Opening the AMC2-4WE case

Figure 4.9: Opening the AMC2-16ION case

Figure 4.10: Opening the AMC2-16IOE case

Page 38: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

38 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Page 39: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 39

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

4.4 Closing the CaseBefore aligning the covers, unplug any pluggable screw connectors. Insert the hooks on thelower edge of the front cover into the lugs on lower edge of the plastic back cover [1]. Pleaseensure that the BOSCH logo is not upside-down. The upper edge of the front cover now alignswith the two-point snap-in closures on the upper edge of the back cover [2], and may thus beclicked gently into place.Hence the closing process is the reverse of the opening process.

1

2

Figure 4.11: Closing the case

Figure 4.12: Closing the case

Page 40: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

40 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 4.13: Closing the extension case

Notice!Risk of damage to equipmentIf excessive force is required to close the front cover then it is probably incorrectly hookedinto the back cover. In such cases the display ’Dialog’ button in the front cover will bemisaligned and will not function correctly.

4.5 Cabling

Notice!Risk of malfunctionThe cables used in the AMC2-4R4 access control system are not prone to electricalinterference. However, you should avoid routing cables close to heavy load switching cablesand equipment. If this is unavoidable, cross the cable at right angles every 1 to 2 m (3 to 6 ft)to reduce interference.

Notice!Risk of malfunctionThe cables used in the AMC2-4W access control system are not prone to electricalinterference. However, you should avoid routing cables close to heavy load switching cablesand equipment. If this is unavoidable, cross the cable at right angles every 1 to 2 m (3 to 6 ft)to reduce interference.

4.5.1 Conductor data for power to AMC2With the calculation below you can find out which cable type must be used. If you connect thepower supply and the AMC-device with the delivered cable set from the enclosure thecalculation is not necessary.

Page 41: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 41

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

For distances below 25 m (75 ft) use AWG18 conductors (1mm²). For longer distances, installan additional power supply close to the AMC2 controller.Please, calculate the voltage drop by checking the conductor specifications for characteristicresistance values. The voltage drop shall not exceed 2 V.Example:Length = 100 m/328 ftU = 12V, I = 1A, maximum UDrop = 2V

i.e. RAWG18 (acc. specs) = 6.385 or 20,948

UDrop = 20,948 x 0.1 km x 1A = 2.1V

UDrop = 6.385 x 328 ft x 1A = 2.1VCritical condition! Install the power supply closer to the controller.External power supplies used must be UL certified and must be located in the same room asthe connected AMC2 device. Recommended maximum distance between power supply unitand AMC2 is 3 m (9.84 ft).

Notice!These specifications apply to power supply, readers, relay outputs, and extension interface.Regarding inputs, specific voltage-drop values need to be taken into account. Refer toConnecting Analog Input Devices, page 82.

Page 42: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

42 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

4.6 Grounding and ShieldingThe main grounding point at the AMC2-4R4 is connected to pin 2 of the power supplyconnector - see Connecting Diagrams, page 102.It is good practice to shield all wires carrying low level signals.

The main grounding point at the AMC2-4W is connected to pin 2 of the power supplyconnector - see Connecting Diagrams, page 102.It is good practice to shield all wires carrying low level signals.

The AMC2-4R4 allows you to create a central ground or shielding point, simply by settingcertain jumpers. Set these jumpers only if grounding or shielding is not achieved by othermeans.The AMC2-4W allows you to create a central ground or shielding point, simply by settingcertain jumpers. Set these jumpers only if grounding or shielding is not achieved by othermeans.

The AMC2 controller allows you to create a central ground or shielding point, simply by settingcertain jumpers. Set these jumpers only if grounding or shielding is not achieved by othermeans.1. If the AMC2-4R4 has its own power - as in the third example in Overview - Power supply/

consumption, page 49 - the shield will be connected to pin 2 of the power supplyconnector - see Connecting Diagrams, page 102.

2. If the extension module is powered from the AMC2 controller - as in the second examplein Overview - Power supply/consumption, page 49 - the connection should be made as inthe RS-485 for extension modules, page 65 diagram.

3. If more than one extension module is to be connected to an AMC2 controller, and all ofthem to receive power from it as well, then use the RS-485 extension interface for theconnection.

Notice!In the second and third case the jumper on the bottom side of the AMC2-controller must tobe set - see the installation manual of the AMC2-4W.

Notice!Risk of malfunctionEnsure that no ground loops are formed.

Notice!In general the following apply:If the devices have their own power supplies, the shielding is applied to one side only. Thefree end should be insulated to avoid inadvertent connections.If one device is fed power by another, the cable shielding should be applied to both sides.

Page 43: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 43

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

4.6.1 Grounding for Host Interface

A 1:

A 2:

A 3:

Delivery status

JP1

JP2

JP1

JP2

A

Figure 4.14: Location of ground jumper RS-485 host interface

Figure 4.15: Location of ground jumper RS-485 host interface

The internal ground of the controller is always connected with the ground of the RS-485 host. The jumper setting 1 shows the factory settings.

The internal ground of the AMC2-4W is always connected with the ground of the RS-485 host. The jumper setting 1 shows the factory settings.

The jumper setting A1 shows the factory settings.

Jumper JP1 connects the internal ground of the AMC2-4R4 to the ground of the RS-485 hostinterface.

Jumper JP2 manages the signal ground.

The jumper setting A1 shows the factory settings.

Jumper JP1 connects the internal ground of the AMC2-4W to the ground of the RS-485 hostinterface.

Jumper JP2 manages the signal ground.

This jumper manages the signal ground.

Settings for jumper JP1:If the ground conductor and the shield on the host are not connected and:– no party line exists, the jumper JP1 is set (= A2)– a party line exists, the jumper JP1 is set at the first device only (= A2)

Page 44: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

44 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Settings for jumper JP2:If the ground conductor and the shield on the host are not connected and:– no party line exists, the jumper JP2 is set (= A3)– a party line exists and signal ground is connected, the jumper JP2 is set at the first device

only (= A3)– a party line exists and signal ground is not connected, the jumper JP2 is set at all devices

(= A3)Settings for the jumper:If the ground conductor and the shield on the host are not connected and:– no party line exists, the jumper is set– a party line exists and signal ground is connected, the jumper is set at the first device

only– a party line exists and signal ground is not connected, the jumper is set at all devices

4.6.2 Grounding for Extension Interface

Delivery statusB 1:

B 2:

B

Figure 4.16: Location of ground jumper bottom side

Figure 4.17: Location of ground jumper bottom side

Figure 4.18: Location of ground jumper bottom side

Page 45: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 45

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Jumper B connects the internal ground of the AMC2-4R4 to the RS-485 ground of the slaveinterface. Only set jumper B (B2) if the AMC2-4R4 powers all other peripheral devices directlyconnected to it.Jumper B connects the internal ground of the AMC2-4W to the RS-485 ground of the slaveinterface. Only set jumper B (B2) if the AMC2-4W powers all other peripheral devices directlyconnected to it.

The jumper setting A1 shows the factory settings.Jumper connects the internal ground of the AMC2-4R4 to the ground of the RS-485 slaveinterface. Set Jumper A2 only at the first AMC2-4R4 of a party line Overview - Power supply/consumption, page 49.

4.6.3 Grounding for Bus Interfaces

Figure 4.19: Location of ground jumper bus interfaces

Figure 4.20: Location of ground jumper bus interfaces

Jumper C (for the second bus) and jumper D (for the first bus) connects the internal groundof the AMC2 to the RS-485 ground of the bus. Only set jumper C and D (C2 or D2) if the AMC2powers all other peripheral devices which are directly connected to the AMC2.

Page 46: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

46 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

4.7 Connecting Power SupplyConnect the power supply to the POWER 7-pin pluggable screw connector. Refer toConnecting Diagrams, page 102 for a complete diagram of the power supply connector.

Figure 4.21: Location of the power supply connector

Figure 4.22: Location of the power supply connector

Figure 4.23: Location of the power supply connector

Connect an external power supply (10 - 14 Vdc) for the AMC2 device at pin 1 (positive) andpin 3 (0 V) of the pluggable screw connector.

If an uninterruptible power supply (UPS) is used, the relay output for power good signals fromthe UPS is connected to the following pins:– pin 4 and 7 for power good AC– pin 5 and 7 for power good Battery– pin 6 and 7 for power good DC

Page 47: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 47

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Otherwise these pins must be short-circuited.

Notice!The battery status is checked every 5 minutes by the power supply unit (APS-PBC-60 or APS-PSU-60).As the battery charging/discharging levels tend to vary, the AMC2 provides information aboutthe battery status every 10 minutes. This feature allows a more reliable battery statusinformation.

Notice!To build a UL listed configuration, refer to UL Requirements

4.7.1 Direct Power SupplyConnect the power supply to the POWER 7-pin pluggable screw connector. Refer toConnecting Diagrams, page 102 for a complete diagram.

Figure 4.24: Location of the power supply connector

Figure 4.25: Location of the power supply connector

Connect an external power supply (10 - 30 Vdc) for AMC2-4R4 at pin 1 (positive) and pin 3 (0V) of the pluggable screw connector.

Page 48: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

48 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

If an uninterruptible power supply (UPS) is used, the relay output for power good signals fromthe UPS is connected to the following pins:– pin 4 and 7 for power good AC– pin 5 and 7 for power good Battery– pin 6 and 7 for power good DCOtherwise these pins must be short-circuited.

4.7.2 Power Supply via RS-485 InterfaceThe power can also be supplied by the AMC2-4W. In this case power pins 1 and 2 should beconnected, as well as data lines on pins 3 - 6.

Figure 4.26: Interface for internal power supply

Figure 4.27: Interface for internal power supply

Page 49: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 49

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

4.7.3 Overview - Power supply/consumption

Figure 4.28: Example configurations

a = AMC2-4WE

b = AMC2 I/O Extension board

line = Power supply

broken line = Data line

Example Components used Output power Consumption Available Constant load

1 PS + AMC2-4W 60VA 5VA 55VA 25VA

2 PS + AMC2-4W +AMC2-4WE

60VA 2 x 5VA 50VA 20VA

PS + AMC2-4W +AMC2-4WE +Extension

60VA 3 x 5VA 45VA 15VA

3 PS + AMC2-4WandPS + AMC2-4WE

60VA+60VA

5VA+5VA

55VA+55VA

25VA+25VA

PS + AMC2-4Wand

60VA+60VA

5VA+2 x 5VA

55VA+50VA

25VA+20VA

Page 50: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

50 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Example Components used Output power Consumption Available Constant load

PS + AMC2-4WE +Extension

4 PS + AMC2-4W +ExtensionandPS + AMC2-4WE

60VA

+60VA

2 x 5VA

+2 x 5VA

50VA

+50VA

20VA

+20VA

Tab. 4.1: Overview - power supply and power consumption

Figure 4.29: Example configurations

Example Used components Outputpower

OwnUsage

available Constantload

1 PS + AMC2 60VA 5VA 55VA 25VA

2 PS + AMC2 + 60VA 2 x 5VA 50VA 20VA

Page 51: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 51

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Example Used components Outputpower

OwnUsage

available Constantload

Extension

using further Extensions the values decrease

PS + AMC2 +2 x Extension

60VA 3 x 5VA 45VA 15VA

PS + AMC2 +3 x Extension

60VA 4 x 5VA 40VA 10VA

3 PS + AMC2andPS + Extension

60VA+60VA

5VA+5VA

55VA+55VA

25VA+25VA

using further Extensions the values decrease

PS + AMC2andPS + 2 x Extension

60VA+60VA

5VA+2 x 5VA

55VA+50VA

25VA+20VA

PS + AMC2andPS + 3 x Extension

60VA+60VA

5VA+3 x 5VA

55VA+45VA

25VA+15VA

using more than two Extensions this combination is recommended

4 PS + AMC2 +ExtensionandPS + Extension +Extension

60VA+60VA

2 x 5VA+2 x 5VA

50VA+50VA

20VA+20VA

Table 4.2: Overview - power supply and power consumption

Example Used components Output power Own usage Available Constant load

1 PS + AMC2-4W 36VA 5VA 31VA 25VA

2 PS + AMC2-4W +AMC2-4WE

36VA 2 x 5VA 26VA 20VA

PS - AMC-4W +AMC2-4WE +Extension

36VA 3 x 5VA 21VA 15VA

using further Extensions the values decrease

3 PS + AMC2-4Wand PS + AMC2-4WE

36VA+36VA

5VA+5VA

31VA+31VA

25VA+25VA

PS + AMC2-4Wand PS + AMC2-4WE +Extension

36VA+36VA

5VA+2 x 5VA

31VA+26VA

25VA+20VA

using further Extensions the values decrease

Page 52: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

52 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Example Used components Output power Own usage Available Constant load

using more than two Extensions this combination is recommended

4 PS + AMC2-4W +Extensionand PS + AMC2-4WE

36VA+36VA

2 x 5VA+2 x 5VA

26VA+26VA

20VA+20VA

Table 4.3: Overview - power supply and power consumption

Explanations for the table columns:

Output power Power provided by the power supply.

Own usage Power used by AMC2 device

Available Power remaining for external devices

Constant load Amount of the available power that canbe drawn constantly.

Hence Example 1 can be read as follows:Of the total incoming power (60VA) 5VA will be drawn by theAMC2 itself . This leaves 55VA to support external devices.25VA of these 55VA can be used for constant load (e.g. a cardreader) leaving 30VA for occasional peak usage (e.g. a dooropener).

Explanations for the table columns:

Output power Power provided by the power supply.

Own usage Power used by AMC2 device

Available Power remaining for external devices

Constant load Amount of the available power that canbe drawn constantly.

Hence Example 1 can be read as follows:Of the total incoming power (36VA) 5VA will be drawn by theAMC2 itself . This leaves 31VA to support external devices.25VA of these 31VA can be used for constant load (e.g. a cardreader) leaving 6VA for occasional peak usage (e.g. a dooropener).

Page 53: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 53

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

4.8 Ethernet Host InterfaceThe AMC2-4R4 offers a 10/100 Mbit/s Ethernet auto-sensing interface to connect to a localarea network or host computer.A complete connection diagram of the Ethernet host interface is shown in chapter ConnectingDiagrams, page 102.The AMC2-4W offers a 10/100 Mbit/s Ethernet auto-sensing interface to connect to a localarea network or host computer.

Notice!Use a CAT5 or higher version to connect the AMC2-4W with the network.

A complete connection diagram of the Ethernet host interface is shown in chapter ConnectingDiagrams, page 102.

Figure 4.30: Location of the Ethernet interface

Figure 4.31: Location of the Ethernet interface

Page 54: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

54 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 4.32: Location of the Ethernet interface

Notice!After connecting a new AMC2 device to a network using DHCP, it can take some time beforethe new AMC2 device is recognized by the remote server.You can accelerate this process by running the following command:ipconfig /flushdns

This makes the AMC2 device immediately available by its name.

Notice!Using the Ethernet connection, the switches 1 and 5 must remain in Pos. ON (=factorysetting).

Page 55: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 55

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

4.9 RS-485 Host Interface

Notice!The RS-485 interface can be used either for the host connection or to connect extensionboards. If extension boards are used then the host connection must be by Ethernet.

An RS-485 host system can consist of up to eight AMC2 controllers connected using 2- or 4-wire connection.

Figure 4.33: Configuration of a RS-485 host system

1 = Host

2 = RS-232 connection

3 = RS-232 / RS-485 converter

4 = RS-485 bus

5 = AMC2 controller

Page 56: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

56 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

The following conditions apply for an RS-485 bus system:– A bus system consists of a bus line and/or one or more branch lines.– Cable lengths exceeding 100 m (300 ft) must be installed as bus lines.– Branch lines are branching connections from a bus line.– Peripheral devices are AMC2 which are connected to the host computer.– Maximum cable length of a bus line must not exceed 1200 m (4000ft).– The cable length of branch lines must not exceed 100m (330ft).– Any bus line conductor connects up to eight AMC2. Do not exceed the maximum number

of devices.To use RS-485 mode at the AMC2-4R4 , connect the data cables to the pluggable screwconnector of the RS-485 host interface. The setting of the AMC2-4R4 must correspond withthe settings of the RS-232 / RS-485 converter.

Figure 4.34: RS-485 host interface

Figure 4.35: RS-485 host interface

Figure 4.36: RS-485 host interface

Page 57: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 57

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Refer to– , page 61– , page 63– , page 61– , page 63

4.9.1 RS-485 Two Wire Connection

Figure 4.37: Connection scheme of a RS-485 two wire connection

1 = signal ground

2 = TxRx+

3 = TxRx-

4 = shield

Figure 4.38: Setting of the jumpers for RS-485 two wire connections

Figure 4.39: Setting of the jumpers for RS-485 two wire connections

For RS-485 two wire connection, set the AMC-MUX DIL switch at positions 3, 7 and 8 to ON.

Page 58: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

58 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

On the upper side of the AMC panel, put the jumper on the two pins on the right hand side ofconnector 8. Also refer to .Set the RS-485 address of the AMC2 controller using the DIL switch. Refer to DIL switchselector, page 61.

Refer to– , page 16– , page 17– , page 17

4.9.2 RS-485 Four Wire Connection

Figure 4.40: Connection scheme of an RS-485 four wire connection

1 = shield

2 = TxRx+

3 = TxRx-

4 = signal ground

5 = Tx+

6 = Tx-

Figure 4.41: Settings for RS-485 four wire connection

Page 59: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 59

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

For RS-485 four wire connection, set the AMC-MUX DIL switch at positions 3, 5 and 6 to ON.On the upper side of the AMC panel, put the jumper on the two pins on the right hand side ofthe connector 8. Also refer to . Set the RS-485 address of the AMC2 controller using the DILswitch. Refer to DIL switch selector, page 61. A complete connection diagram of the RS-485host interface is shown in .

Notice!See the notices for setting the RS-232 / RS-485 converter.

Notice!If a four-wire connection is used the interface must be set up as a crosslink.

Page 60: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

60 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Refer to– , page 16– , page 17– , page 17– DIL switch selector, page 61– , page 112– , page 102

4.10 RS-232 Host InterfaceThe AMC2 offers an RS-232 serial interface to connect a host computer or serial modem.

Notice!Risk of malfunctionCable length between two RS-232 COM serial interfaces must not exceed 15 meters (45 ft).

Figure 4.42: Location of the RS-232 serial interface

Figure 4.43: Location of the RS-232 serial interface

As the AMC2 controller is conceptionally a PC, it is not possible to connect them directly usingnormal cables. Use instead a null modem or “crossover” cable. A complete connectiondiagram of the RS-232 host interface is shown in chapter Connecting Diagrams, page 102

Page 61: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 61

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

4.11 DIL switch selectorDIL switches are used to configure the host settings. The first four DIL switches for addressselection. Switch 5 selects one of the two different protocols, SDEB and BPA (according toDIN6619).

Notice!If using an Ethernet connection, set switch 1 to ON (= factory setting).

Figure 4.44: Location of the selector for host settings

AddressDIL Switches

1 2 3 4

none OFF OFF OFF OFF

1 ON OFF OFF OFF

2 OFF ON OFF OFF

3 ON ON OFF OFF

4 OFF OFF ON OFF

5 ON OFF ON OFF

6 OFF ON ON OFF

7 ON ON ON OFF

8 OFF OFF OFF ON

Tab. 4.4: Setting the address via the DIL switch

ModeDIL Switches

5 6

ON SDEB RS-232

OFF BPA RS-485

Tab. 4.5: Protocol and connection settings

Page 62: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

62 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

4.11.1 Host settingsDIL switches are used to configure the host settings. The first four DIL switches for addressselection define the RS-485 address of the AMC2 in a RS-485 bus system. Switch 5 selectsone of the two different protocols, SDEB and BPA (according to DIN6619).Switch 6 sets the connection to the host system to either RS-232 or RS-485.

Notice!If using an Ethernet connection, set switch 1 to ON (= factory setting).If using an RS-232 connection, set the address by configuring it in the Access Control System.This is a point-to-point connection that is usually configured as address 1, so set switch 1 toON.

Figure 4.45: Location of the selector for host settings

AddressDIL Switches

1 2 3 4

None OFF OFF OFF OFF

1 ON OFF OFF OFF

2 OFF ON OFF OFF

3 ON ON OFF OFF

4 OFF OFF ON OFF

5 ON OFF ON OFF

6 OFF ON ON OFF

7 ON ON ON OFF

8 OFF OFF OFF ON

Tab. 4.6: Setting the address via the DIL switch

Instructions for DIL switch 5Set SDEB (= DIL switch 5 to ON) in the following cases– Ethernet host connection– RS-485 host connection, provided only one AMC2 is connected on the busSet BPA (= DIL switch 5 to OFF) in the case of an– RS-485 host connection with more than one and maximum eight AMC2s per bus

Page 63: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 63

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Notice!Changing the type of the host connection requires a reset of the AMC2 - see Resetting theSoftware, page 94.

ModeDIL Switches

5 6

ON SDEB RS-232

OFF BPA RS-485

Tab. 4.7: Protocol and connection settings

4.11.2 Setting the hostDIL switches are used to configure the host settings. The first four DIL switches for addressselection define the RS-485 address of the AMC2 in a RS-485 bus system. Switch 5 selectsone of the two different protocols, SDEB and BPA (according to DIN6619).Switch 6 sets the connection to the host system to either RS-232 or RS-485.

Notice!If using an Ethernet connection, set switch 1 to ON (= factory setting).If using an RS-232 connection, set the address by configuring it in the Access Control System.This is a point-to-point connection that is usually configured as address 1, so set switch 1 toON.

Figure 4.46: Location of the selector for host settings

AddressDIL Switches

1 2 3 4

none OFF OFF OFF OFF

1 ON OFF OFF OFF

2 OFF ON OFF OFF

Page 64: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

64 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

AddressDIL Switches

1 2 3 4

3 ON ON OFF OFF

4 OFF OFF ON OFF

5 ON OFF ON OFF

6 OFF ON ON OFF

7 ON ON ON OFF

8 OFF OFF OFF ON

Tab. 4.8: Setting the address via the DIL switch

ModeDIL Switches

5 6

ON SDEB RS-485

OFF BPA Ethernet

Tab. 4.9: Protocol and connection settings

Instructions for DIL switch 5Set SDEB (= DIL switch 5 to ON) in the following cases– Ethernet host connection– RS-485 host connection, provided only one AMC2 is connected on the busSet BPA (= DIL switch 5 to OFF) in the case of an– RS-485 host connection with more than one and maximum eight AMC2s per bus

Notice!Changing the type of the host connection requires a reset of the AMC2 - see Resetting theSoftware, page 94.

– RS-232 host connectionSet BPA (= DIL switch 5 to OFF) in the case of an– RS-485 host connection with more than one and maximum eight AMC2s per bus

Notice!Changing the type of the host connection requires a reset of the AMC2 - see Resetting theSoftware, page 94.

4.11.3 Board SettingsThe address of the board is set using a switch on the board’s underside (see EquipmentConfiguration, page 16). The AMC2-4R4 is always assigned address 0.The extension boards are assigned the addresses 1 to 3.

Page 65: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 65

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Notice!When configuring the system, ensure that the order of boards in the Access Control Systemcorresponds to the addresses you set using this switch.

This order of addressing determines the numbering of the boards’ signals.

Address Signal-No.: Signal-No.:

AMC2-16ION

0 0/ 01 - 16

AMC2-8IOE AMC2-16IOE

1 1/ 01 - 08 1/ 01 - 16

2 2/ 01 - 08 2/ 01 - 16

3 3/ 01 - 08 3/ 01 - 16

Tab. 4.10: Signal numbering according to board address

4.12 RS-485 for extension modules

Notice!The RS-485 interface can be used either for the host connection or to connect extensionboards. If extension boards are used then the host connection must be by Ethernet.

The RS-485 Extension Module Bus expands the AMC2-4R4 with additional I/O modules(AMC2-8IOE, AMC2-16IE, AMC2-16IOE).The RS-485 Extension Module Bus expands the AMC2-4W with additional Wiegand interfaceand/or I/O modules AMC2-4WE (AMC2-8IOE, AMC2-16IE, AMC2-16IOEThe RS-485 Extension Module Bus expands the AMC2-4R4 with additional I/O modules(AMC2-8IOE, or AMC2-16IOE) .The AMC2-4R4 is connected to the AMC2 controller using the RS-485 extension interface. Thisinterface will also be used to connect further extension modules.

Figure 4.47: Location of the RS-485 extension module bus

Page 66: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

66 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 4.48: Location of the RS-485 extension module bus

Figure 4.49: Location of the RS-485 extension module bus

Figure 4.50: Location of the RS-485 extension module bus

Page 67: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 67

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Figure 4.51: Location of the RS-485 extension module bus

Figure 4.52: Location of the RS-485 extension module bus

Up to three expansion modules can be connected to provide additional in- and outputs, forexample, for elevator control.

Notice!This controller is currently a project version.

You can find further information about the extension boards in their installation manuals.A complete connection diagram of the RS-485 extension module bus is shown in ConnectingDiagrams, page 102.

Page 68: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

68 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 4.53: Connection of an extension module to an AMC2

4.12.1 AddressingThe address of the board is set using a switch on the board’s underside (see EquipmentConfiguration, page 16).The address of the board is set using a switch on the board’s underside (see EquipmentConfiguration).Up to three extension boards (BIS) can be connected to one AMC2 - depending on that theaddresses 1 to 3 can be assigned, only.

Notice!When configuring the system, ensure that the order of boards in the access control softwarecorresponds to the addresses you set using this switch.

This order of addressing determines the numbering of the boards’ signals - see ConnectingDiagrams, page 102.

Address Signal-No.:

AMC2-8IOE AMC2-16IOE

1 1/ 01 - 08 1/ 01 - 16

2 2/ 01 - 08 2/ 01 - 16

3 3/ 01 - 08 3/ 01 - 16

Tab. 4.11: Signals numbering

Page 69: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 69

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

4.13 Wiegand Interface for Card Readers

Notice!If your reader requires a voltage other than 12V or is the power consumption more than 200mA then it will require an external power supply.

The AMC2-4W provides four ports for connecting a maximum of 4 readers with Wiegandinterfaces. Each interface is connected using a 10-pin pluggable screw - refer to ConnectingDiagrams, page 102 .

Figure 4.54: Location of the Wiegand interfaces for external devices

Figure 4.55: Location of the Wiegand interfaces for external devices

Page 70: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

70 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 4.56: Location of the Wiegand interfaces for external devices

These interfaces are point-to-point connections, and each can support only a single readerwith a maximum cable length of 90 m (300 ft) for 24 AWG or 150 m (500 ft) for 22 AWG.Readers are addressed according to their respective interface numbers.Refer to Connecting Diagrams, page 102 for a complete wiring diagram of the Wiegand readerinterface .

Notice!Reference UL Requirements for readers approved for UL installations.

4.13.1 Connecting different reader typesConnection schemes and reader wiring colors vary from type to type, and so may differ fromthe 10-pole Wiegand to AMC connection shown in Connecting Diagrams, page 102.

Notice!If your reader requires a voltage other than 12V or is the power consumption more than 200mA then it will require an external power supply.

Notice!The list below might become obsolete. For current reader types, please refer to the BoschOnline-Catalogue.

Wiegand reader type W 1This wiring diagram refers to the following readers from the BOSCH catalog:

Page 71: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 71

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

CTN Part Number

ARD-ProxPointPlus 4.998.141.821

ARD-MiniProx 4.998.141.822

ARD-Prox80 4.998.141.823

ARD-R10 4.998.127.612

ARD-R30 4.998.127.613

ARD-R40 4.998.127.614

ARD-RK40-AMC01 F.01U.514.655

Notice!Reference UL Requirements for readers approved for UL installations.

Notice!The terminal assignment shown above does not apply to the W1 readers ARD-R90-AKT00(F.01U.030.232) and ARD-R90 (F.01U.027.003). Please use instead the installation guide ofthe card reader itself.The Wiegand reader interface of the AMC2-4R4 does not provide sufficient power for theARD-R90. Please plan an external power supply for the ARD-R90.

Wiegand reader type W 2This wiring diagram refers to the following readers from the BOSCH catalog:

CTN Part Number

ARD-P0834-01 F.01U.028.449

ARD-H0834-01 F.01U.028.448

ARD-W2626-01 F.01U.028.443

ARD-W2634-01 F.01U.028.444

ARD-Prox26-01 F.01U.028.446

Notice!The beeper will be controlled by the reader.

Page 72: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

72 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Wiegand reader type W 3This wiring diagram refers to the following readers from the BOSCH catalog:

CTN Part Number

ARD-AYK12 F.01U.075.408

ARD-AYJ12 F.01U.075.388

ARD-AYH12 F.01U.075.389

ARD-AYQ12 F.01U.075.390

ARD-AYCE65B F.01U.075.391

Wiegand reader type W 4The reader has an additional DIL switch to choose the following parameter settings.

S1 = on The beeper is controlled by input 1.

S2 = on The beeper will always be set after card reading.

S3 = on The LED displays will be controlled by the reader.

S4 = off

S5 = on The beeper is controlled by input 2.

Notice!In the default delivery status pin 2 is set to ON.

4.14 RS-485 Interface for Card ReadersThe AMC2-4R4 has four RS-485 interfaces. Each interface is connected using a 10-pinpluggable screw connector (S2, S7, S14, and S19).

Figure 4.57: Location of the RS-485 interfaces for external devices

Page 73: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 73

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Figure 4.58: Location of the RS-485 interface for external devices

The interfaces 1 and 2 build a bus (bus 1) for its own like the interfaces 3 and 4 (bus 2).All eight possible readers can connect to each of the busses in any combination. However, theaddresses of the readers must be unique on an AMC2.Two readers can connect to the bus.The voltage on the interface is equal to the input voltage of the AMC2-4R4A complete connection diagram of the RS-485 interface is shown in chapter ConnectingDiagrams, page 102.

Notice!Please check which voltage the readers require. If this does not correspond to the inputvoltage, this will require an external power supply.

Notice!If the current consumption on the interface is higher than 1.5A then change the distributionto the other interfaces or use an external power supply for the reader.

Notice!Damage to the device due to wrong voltageMake sure that the readers support the same voltage as the power supply unit that isconnected to the AMC. Readers that do not support the same voltage will be damaged.

Refer to– RS-485 Host Interface, page 55

4.15 RS-232 Interface for Card ReadersThe AMC2-4R4 has RS-232 interface to integrate with RS-232 compatible interfaces. Eachinterface is connected using a pluggable screw connector .

Page 74: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

74 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 4.59: Location of the RS-232 interfaces for external devices

Figure 4.60: Location of the RS-232 interface for external devices

The interface is a point-to-point connection. You can connect only one reader. The cablelength is limited to 15 m (49 ft).

Notice!A complete connection diagram of the RS-232 interface is shown in , page 116.

Notice!A complete connection diagram of the RS-232 interface is shown in chapter ConnectingDiagrams, page 102

Page 75: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 75

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

4.16 Connecting Relay OutputsTo operate locks or alarm systems, the AMC2-4R4 has eight relay outputs. The outputs will beconnected to the 3-pin pluggable screw connectors S5, S6, S10, S11, S17, S18, S22, and S23- refer to chapter Connecting Diagrams, page 102.To operate locks or alarm systems, the AMC2-4W has eight relay outputs. The outputs will beconnected to the 3-pin pluggable screw connectors S5, S6, S10, S11, S17, S18, S22, and S23- refer to chapter Connecting Diagrams, page 102.

The AMC2 8I-8O-EXT has the connectors S6 - 9 and S14 - 17, only.

Figure 4.61: Location of the relay output connectors

Figure 4.62: Location of the relay output connectors

Page 76: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

76 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 4.63: Location of the relay output connectors

Figure 4.64: Location of the relay output connectors

Figure 4.65: Location of the relay output connectors

Page 77: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 77

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Figure 4.66: Location of the relay output connectors

Each relay output can operate in ‘wet’ mode, using the AMC2-4R4's internal 12/24 Vdc powersupply for external devices or ‘dry’ mode with potential free contacts for externally poweredsystems.

Figure 4.67: Wet mode and dry mode of the AMC2 relay outputs

Each relay output can operate in ‘wet’ mode, using the AMC2-4W 's internal 12/24 Vdc powersupply for external devices or ‘dry’ mode with potential free contacts for externally poweredsystems.

Figure 4.68: Wet mode and dry mode of the AMC2 relay outputs

Page 78: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

78 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Notice!Risk of damage to equipmentTo prevent damage to the relays note the following specifications.

– the maximum switching current is 1.25 A– the maximum switching voltage is 30 Vdc– only ohm resistive load can be connected to the relay– inductive loads have to be short circuited using recovery diodes, see image below. These

diodes (1N4004) are supplied with every AMC2-4R4 package.– If you need higher voltage for special applications you have to connect external relays to

the outputs. Depending on the power supply mode, it is recommended to use thefollowing Wiegand relay types:– Flare move 12DC1W10A– Flare move 24DC1W16A

If using locally manufactured products, please ensure that the specifications of the productare identical with the those listed above.A complete connection diagram of the relay output connectors is shown in ConnectingDiagrams, page 102.

Figure 4.69: Recovery diode schematic

1 normally open/normally closed 1 normally open/normallyclosed

2 common 2 common

3 load 3 load

4 diode 4 diode

5 voltage source

Notice!Risk of damage to equipmentDo not connect externally powered devices in wet mode. This can damage the AMC2-4R4.

Page 79: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 79

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Each relay output has a separate jumper setting on the underside of the circuit board to selectdry (E1) or wet (E2) mode.

Notice!Risk of damage to equipmentTo prevent damage to the relays note the following specifications.

– the maximum switching current is 1.25 A– the maximum switching voltage is 30 Vdc– only ohm resistive load can be connected to the relay– inductive loads have to be short circuited using recovery diodes, see image below. These

diodes (1N4004) are supplied with every AMC2-4W package.– If you need higher voltage for special applications you have to connect external relays to

the outputs. Depending on the power supply mode, it is recommended to use thefollowing Wiegand relay types:– Flare move 12DC1W10A– Flare move 24DC1W16A

If using locally manufactured products, please ensure that the specifications of the productare identical with the those listed above.A complete connection diagram of the relay output connectors is shown in ConnectingDiagrams, page 102.

Figure 4.70: Recovery diode schematic

1 normally open/normally closed 1 normally open/normallyclosed

2 common 2 common

3 load 3 load

4 diode 4 diode

5 voltage source

Notice!Risk of damage to equipmentDo not connect externally powered devices in wet mode. This can damage the AMC2-4W .

Page 80: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

80 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Each relay output has a separate jumper setting on the underside of the circuit board to selectdry (D1) or wet ( D2) mode.

Figure 4.71: Location of relay output jumpers (bottom side)

Figure 4.72: Location of relay output jumpers (bottom side)

Figure 4.73: Location of relay output jumpers

Figure 4.74: Location of relay output jumpers

Page 81: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 81

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Notice!The positions of the jumpers 1 and 2 are interchanged related to the correspondinginterfaces.

Page 82: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

82 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

4.17 Connecting Analog Input DevicesThe AMC2-4R4 has 8 analog inputs, for example, for potential-free lock mechanisms, or todetect whether a lock is closed or open. The inputs will be connected to the 2-pin pluggablescrew connectors: S3, S4, S8, S9, S15, S16, S20 and S21 - refer to Connecting Diagrams, page102.The AMC2-4W has 8 analog inputs, for example, for potential-free lock mechanisms, or todetect whether a lock is closed or open. The inputs will be connected to the 2-pin pluggablescrew connectors: S3, S4, S8, S9, S15, S16, S20 and S21 - refer to Connecting Diagrams, page102.The AMC2-8IOE has the connectors S2 - 5 and S10 - 13, only.

Notice!Risk of damage to equipmentDo not connect external power supply to the AMC2 inputs.When connecting a relay output to an AMC2 input use dry mode with potential-free contact -refer to Connecting Relay Outputs, page 75.

Figure 4.75: Location of the analog input connectors

Figure 4.76: Location of the analog input connectors

Page 83: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 83

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Figure 4.77: Location of the analog input connectors

Figure 4.78: Location of the analog input connectors

Figure 4.79: Location of the analog input connectors

Page 84: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

84 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 4.80: Location of the analog input connectors

The AMC2-4R4 can also detect the wiring conditions ‘short circuit’ and ‘broken’, and hencetrigger an alarm if the appropriate devices are connected.

1. Door open: RS + RP

2. Door closed: RS

3. Open wire: RS + RP = ∞4. Short circuit: RS + RP = 0

The resistor values can vary and depend on the used lock system.

The extension package includes 2,2 kΩ resistors which can be used to replace RS and RP

resistor.

The AMC2-4W can also detect the wiring conditions ‘short circuit’ and ‘broken’, and hencetrigger an alarm if the appropriate devices are connected.

Page 85: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 85

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

1. Door open: RS + RP

2. Door closed: RS

3. Open wire: RS + RP = ∞4. Short circuit: RS + RP = 0

The resistor values can vary and depend on the used lock system.

The extension package includes 2,2 kΩ resistors which can be used to replace RS and RP

resistor.

To detect the four states, the voltage drop in the connecting cable may not exceed specialvalues. The following table shows the maximum values of permissible cable resistancedepending on the used resistor combination.

RP 1k 1k2 1k5 1k8 2k2 2k7 3k3 3k9 4k7 5k6 6k8 8k2

RS

1k 220 220 220 210 200

1k2 260 270 270 270 260 240

1k5 310 330 340 350 350 340 310 280

1k8 340 380 390 410 410 410 400 370 330 290 200

2k2 430 460 490 510 520 510 500 460 420 340 240

2k7 490 540 570 620 630 640 640 620 580 510 420

3k3 610 650 700 740 770 780 770 750 700 620

3k9 720 790 850 890 910 910 910 880 810

4k7 880 960 960 970 1100 1100 1050 1050

5k6 1050 1100 1200 1200 1300 1300 1250

6k8 1300 1400 1500 1500 1500 1500

Page 86: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

86 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

RP 1k 1k2 1k5 1k8 2k2 2k7 3k3 3k9 4k7 5k6 6k8 8k2

RS

8k2 1500 1650 1700 1800 1900

Table 4.12: Maximum values of cable resistance per used resistor combination in Ohm

Notice!For UL Access controls installations, only the RS = 2k2 and RP = 2k2 End-of-Line resistors maybe used.

Notice!We recommend using serial resistors (RS) no higher than 5K6 in order to obtain clearmeasurements.

Page 87: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 87

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

4.18 Tamper ProtectionTo protect the AMC2-4R4 against unauthorized access and so prevent tampering withsensitive data, the AMC2-4R4 provides an additional interface to connect external tampercontacts. This interface is a potential-free 2-pin pluggable screw connector marked with T.When not in use this tamper contact should be shorted.To protect the AMC2-4W against unauthorized access and so prevent tampering with sensitivedata, the AMC2-4W provides an additional interface to connect external tamper contacts. Thisinterface is a potential-free 2-pin pluggable screw connector marked with T. When not in usethis tamper contact should be shorted.

Figure 4.81: Location of the tamper protection contact

Figure 4.82: Location of the tamper protection contact

Page 88: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

88 en | Installing Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 4.83: Location of the tamper protection contact

Figure 4.84: Location of the tamper protection contact

Figure 4.85: Location of the tamper protection contact

Page 89: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Installing | en 89

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Figure 4.86: Location of the tamper protection contact

Page 90: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

90 en | Operating Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

5 OperatingNotice!To build a UL listed configuration, refer to UL Requirements

5.1 Status Display of the AMC2Because the AMC2-4R4 has no display of its own, the AMC2 controller displays statusinformation about the input and output settings of the AMC2.The liquid crystal display delivers status information about the AMC2-4R4. Push the 'Dialog'button to switch between different modes.The liquid crystal display delivers status information about the AMC2-4W . Push the 'Dialog'button to switch between different modes.

Figure 5.1: Location of the ’Dialog’ button

Figure 5.2: Location of the ’Dialog’ button

Figure 5.3: Location of the ’Dialog’ button

Page 91: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Operating | en 91

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Push Display (Example) Description

0 V01.00 02.03.07orLBUS or BG900

Software versions and date ofthe firmware - every 5 sec.alternating with the display ofthe reader interface.

1a S/N1: 0910019212 BOSCH serial number

1b S/N2: 00000001

2 02.06 15:35:15 (S) Current date and time(S) = Summer; (W) = Winter

3 Dig. IO: :::::::::::::::: Display of the digital contacts:the input signals set will beshown with an extension above- output signals with anextension below.

3a Dig. I1: :::::::::::::::: If there are I/O-Boardsconnected the signals will beshown on separate pages.

3b Dig. I2: ::::::::::::::::

3c Dig. I3: ::::::::::::::::

4 MAC 0010174C8A0C Network device address (MAC)

5 N AMC-1234-5678 Network name of the AMC2

6 I 192.168.10.18 IP-address of the AMC2

7 G 192.168.10.255 IP-address of the gateway(Version V 00.44 or higher)

8 M 255.255.255.0 Subnetmask(Version V 00.44 or higher)

9 H 192.168.10.10 IP-address of the hostcomputer

10 DHCP 1 DHCP-status:1 = on0 = off

11 D 192.168.10.1 IP-address of the DNS server

12 Host: + "C" Host activity:+ = online- = offline"C" = Counter of the receiveddata packages from the hostinterface.RS 485 Bus connection:A = Address 1 … H = Address 8

Page 92: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

92 en | Operating Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

5.2 Configuring the Ethernet InterfaceTo configure the AMC2-4R4 in a TCP/IP network environment, use the AmcIpConfig toolprovided in the following directory on the standalone or the remote server of the BuildingIntegration System:\\Runtime-drive:\MgtS\AccessEngine\AC\bin

To configure the AMC2-4W in a TCP/IP network environment, use the AmcIpConfig toolprovided in the following directory on the standalone or the remote server of the BuildingIntegration System:\\Runtime-drive:\MgtS\AccessEngine\AC\bin

The access control system Access Personal Edition has an entry of this tool in its programfolder:Start > Programs > Access Personal Edition > AmcIpConfig

This tool can be copied and used on every computer on the network.

Notice!Use only alphanumeric characters plus the seperator "-" (minus/dash).Do not use special characters or spaces.The network name must start with a letter.The names are not case sensitive.

Notice!Consult the AmcIpConfig tool’s own online help for details on configuring the AMC2-4R4.

Page 93: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Operating | en 93

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Notice!Use only alphanumeric characters plus the seperator "-" (minus/dash).Do not use special characters or spaces.The network name must start with a letter.The names are not case sensitive.

Notice!Consult the AmcIpConfig tool’s own online help for details on configuring the AMC2-4W .

Page 94: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

94 en | Operating Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

5.3 TroubleshootingIf problems occur, they should first be tackled directly - for example check the Networkconnection, IP-address and DIL switch settings. Nevertheless it is sometimes an indirect helpto reset the AMC2-4R4 unit to its factory defaults.If problems occur, they should first be tackled directly - for example check the Networkconnection, IP-address and DIL switch settings. Nevertheless it is sometimes an indirect helpto reset the AMC2-4W unit to its factory defaults.If there is no indication on the display, check voltage provided from the power supply, powerup the controller.If the controller is not online, or operation is not as expected per configuration:1. Check connections/ configuration as per described in Chapter 4 and Section 5.2.2. Cycle the power of the controller.3. In rare cases reset the controller software as described in Section 5.3.1.4. For factory default reset refer to Section 5.3.2.If problem persists, please request after sales support.If there is no indication on the display, check voltage provided from the power supply, powerup the controller.If the controller is not online, or operation is not as expected per configuration:1. Check connections/ configuration as per described in Chapter 5 and Section 6.2.2. Cycle the power of the controller.3. In rare cases reset the controller software as described in Section 6.3.1.4. For factory default reset refer to Section 6.3.2.If problem persists, please request after sales support.

5.3.1 Resetting the Software1. Insert the provided screwdriver into the hole until it reaches the reset button as shown in

the figure below.2. Press the reset button for at least three seconds.3. The AMC2-4R4 deletes its application program leaving only its bootloader and network

setting.

As soon as it is online again, the AMC2-4R4 bootloader will download a fresh copy of theapplication program and configuration. If the problem persists please request technicalsupport.1. Insert the provided screwdriver into the hole until it reaches the reset button as shown in

the figure below.2. Press the reset button for at least three seconds.3. The AMC2-4W deletes its application program leaving only its bootloader and network

setting.

As soon as it is online again, the AMC2-4W bootloader will download a fresh copy of theapplication program and configuration. If the problem persists please request technicalsupport.

Page 95: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Operating | en 95

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Figure 5.4: Resetting the AMC2

Figure 5.5: Resetting the AMC2 16I-16O-NET

Figure 5.6: Resetting the AMC2-DCUA

Page 96: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

96 en | Operating Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

5.3.2 Resetting the Device to Factory Default1. Reset the AMC2-4R4 as described above.2. Open the upper case of the AMC2-4R4 as described in Opening the Case, page 36.3. Set all six DIL switches of the RS-485 selector to ON as shown in the figure below.4. Press the reset button on the the board.5. Set the DIL switches back in the address state before resetting.

1. Reset the AMC2-4W as described above.2. Open the upper case of the AMC2-4W as described in Opening the Case, page 36.3. Set all six DIL switches of the RS-485 selector to ON as shown in the figure below.4. Press the reset button on the the board.5. Set the DIL switches back in the address state before resetting.

The AMC2-4R4 now has the following network configuration:– DHCP = 1– IP = [assigned by DHCP server or “0.0.0.0” if not available]– Subnet mask = [assigned by DHCP server or “0.0.0.0” if not available]– Password = no passwordThe AMC2-4W now has the following network configuration:– DHCP = 1– IP = [assigned by DHCP server or “0.0.0.0” if not available]– Subnet mask = [assigned by DHCP server or “0.0.0.0” if not available]– Password = no password

Figure 5.7: Resetting the AMC2 to delivery state

Figure 5.8: Resetting the AMC2-DCUA to delivery state

Page 97: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Technical Data | en 97

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

6 Technical DataHardware– Integrated Microcontroller (32 bit, 30 MHz)– SRAM (256 kB)– Serial EEPROM– RTC (real time clock)– Pluggable Compact Flash card– Battery for SRAM and RTC– DIL switch for host settings (address and protocol mode)– Host interfaces

– Ethernet 10/100 Mbit/sHardware– Integrated Microcontroller (32 bit, 30 MHz)– SRAM (256 kB)– Serial EEPROM– RTC (real time clock)– Pluggable– Battery for SRAM and RTC– DIL switch for host settings (address and protocol mode)– Host interfaces

– Ethernet 10/100 Mbit/s– RS-485 2-wire or 4-wire Transfer rate:

38,4 kBit/s, even parity, 7 bit, 1 stop bit

Hardware– Integrated Microcontroller (32 bit, 30 MHz)– SRAM (256 kB)– Serial EEPROM– RTC (real time clock)– Pluggable Compact Flash card– Battery for SRAM and RTC– DIL switch for host settings (address and protocol mode)– Host interfaces

– Ethernet 10/100 Mbit/s– RS-485 2-wire or 4-wire

Transfer rate: 38,4 kBit/s, even parity, 7 bit, 1 stop bit,

– RS-232 Transfer rate: 38,4 kBit/s no parity, 8 bit, 1 stop bit

Hardware– Integrated Microcontroller (32 bit, 30 MHz)– SRAM (256 kB)– Serial EEPROM– RTC (real time clock)– Pluggable Compact Flash card– Battery for SRAM and RTC– DIL switch for host settings (address and protocol mode)– Host interfaces

Page 98: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

98 en | Technical Data Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

– Ethernet 10/100 Mbit/s– Four Wiegand interfaces for up to four card readers

(Output rating: 280 mA)Hardware– Four Wiegand interfaces for up to four card readers

(Output rating: 280 mA each @ 11.8-12Vdc)– Four RS-485 interfaces for up to eight card readers

– Transfer rate: 9,6 kBit/s, no parity, 8 bit, 2 stop bit

– Two RS-232 interfaces for card readers– Transfer rate: 9,6 kBit/s, no parity, 8 bit, 2 stop bit

– Reader interfaces:– one RS-485 interface for max. two readers

Transfer rate: 9,6 kBit/sno parity, 8 bit, 2 stop bit,

– Transfer rate: 19,2 kBit/sno parity, 8 bit, 1 stop bit

– two Wiegand interfaces - each for one reader– Slave interface (RS-232) to connect additional control units - the transfer rate depends

on the connected device– Eight relay outputs

– maximum ratings (wet and dry):switching voltage: 30 Vdcswitching current: 1,25 A

– operating ratings (wet and dry):1,25 A @ 30 Vdc2 A @ 12 Vdc1,5 A @ 24 Vdc

– Eight relay outputs– maximum ratings (wet and dry):

switching voltage: 30 Vdcswitching current: 1,25 A

– operating ratings (dry):1,25 A @ 30 Vdc2 A @ 12 Vdc1,5 A @ 24 Vdc

– operating ratings (wet):8.9-30 Vdc, 1.25 A(voltage output is dependent on board voltage input)

– Eight analog inputs with sabotage monitoring; only connect dry contacts– RS-485 extension interface:

– Transfer rate: 9,6 kBit/s,– no parity, 8 bit, 2 stop bit– Output power rated maximum 2.5 A @ 10 - 14 Vdc (voltage output is dependent on

board voltage input)– Tamper contact for external enclosures– Eight analog inputs with tamper detection; only connect dry contacts

Page 99: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Technical Data | en 99

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

– RS-485 extension interface: Transfer rate: 9,6 kBit/s, no parity, 8 bit, 2 stop bit

– Tamper contact for external enclosures– RS-485 output power rated maximum 2.5 A @ 9.0-30 Vdc (voltage output is dependant

on board voltage input)

Power supply10 to 30 Vdc

Power input10 to 30 Vdc, max 3 APower input10 to 14 Vdc, max 3 Aor via the AMC2-4W

Display64,8 mm x 13,9 mm (2.551 x 0.547 in.)1 line, 16 characters

Power consumptionAMC: 5 VATotal combined output:3A @ 10-12 Vdc2.5A @ 24-30 VdcTotal combined output:3A @ 10-14 VdcPeripheral devices: using the PSU-60– up to 55 VA– constant load: 25 VA

ConnectorsPluggable screw connectors

Protection classIP30

Environment temperature0° C to 50°C (32° F to 122°F)

Environment temperature13° C to 35° C (55° F to 95° F)

HumidityUp to 95%, without condensation

Housing materialABS with OC (UL 94 V-0)

Page 100: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

100 en | Technical Data Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Dimensions(W/H/D) 232 x 90 x 63mm (8.9 x 3.5 x 2.5 in)Weightapprox. 0.53kg (1.2lb)

Notice!The voltage drop from the power supply to the AMC2-4R4 affects the AMC interfaces. Thetotal drop must not exceed 2V!

Notice!To determine the environmental impact of an installation, take into account the most extremevalues of all participating devices. To determine the vulnerability of an installation, take into account the most restrictive valuesof all participating devices.

Notice!The voltage drop from the power supply to the AMC2-4W affects the AMC interfaces. Thetotal drop must not exceed 2V!

Notice!To determine the environmental impact of an installation, take into account the most extremevalues of all participating devices. To determine the vulnerability of an installation, take into account the most restrictive valuesof all participating devices.

Page 101: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Technical Data | en 101

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Page 102: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

102 en | Appendices Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

7 AppendicesNotice!To build a UL listed configuration, refer to UL Requirements

7.1 Connecting Diagrams

Figure 7.1: Connectors on upper PCB

1 Shield

2 Data RxTx+ (2-wire)Data Rx+ (4-wire)

3 Data RxTx- (2-wire)Data Rx- (4-wire)

4 Ground (PAG)

5 Data Tx+ (4-wire)

6 Data Tx- (4-wire)

Tab. 7.13: RS-485 host on upper PCB

Page 103: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Appendices | en 103

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

1 TXD+

2 TXD-

3 RXD+

4 not connected

5 not connected

6 RXD-

7 not connected

8 not connected

Tab. 7.14: Ethernet Network socket (RJ45)

Figure 7.2: Interconnect diagram of the RS-232 serial interface

Page 104: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

104 en | Appendices Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 7.3: Connector blocks of the AMC2-4W

Page 105: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Appendices | en 105

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Figure 7.4: Connector blocks of the AMC2-2R2

Page 106: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

106 en | Appendices Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 7.5: Connector blocks of the AMC2-4R4

Page 107: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Appendices | en 107

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Figure 7.6: Connector blocks of the AMC2-DCUA

Page 108: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

108 en | Appendices Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 7.7: Connector blocks of the AMC2-4WE

Page 109: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Appendices | en 109

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Figure 7.8: Connector blocks of the AMC2-16ION

Page 110: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

110 en | Appendices Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 7.9: Connector blocks of the AMC2-16IOE

Page 111: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Appendices | en 111

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Figure 7.10: Connector blocks of the AMC2-8IOE

Page 112: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

112 en | Appendices Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Figure 7.11: Connector blocks of the AMC2-16IE

1 TXD+

2 TXD-

3 RXD+

4 not connected

5 not connected

6 RXD-

7 not connected

8 not connected

Tab. 7.15: Ethernet Network socket (RJ45)

1 Shield

2 Data RxTx+

3 Data RxTx-

4 Ground (PAG)

5 Data Tx+

6 Data Tx-

Tab. 7.16: RS-485 host

Page 113: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Appendices | en 113

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

1 Power supply, DC positive (10V - 30V)

2 Shield

3 Power supply (0V)

4 UPS (power good signal) - AC

5 UPS (power good signal) - Battery

6 UPS (power good signal) - DC

7 UPS (power good signal) - Common

Tab. 7.17: Power supply

1 red Reader Supply (12V)

2 black Reader Supply (0V)

3 green Data 0

4 white Data 1

5 drain Shield

6 orange green LED

7 brown red LED

8 yellow Beeper

9 blue Hold

10 violet Card Present

Tab. 7.18: Wiegand interface AMC

1 red Reader Supply (12V)

2 black Reader Supply (0V)

3 green Data 0

4 white Data 1 (Clock)

5 purple Shield

6 brown green LED

7

8

9

10

Tab. 7.19: Wiegand interface W2

Page 114: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

114 en | Appendices Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

1 red Reader Supply (12V)

2 black Reader Supply (0V)

3 green Data 0

4 white Data 1 (Clock)

5 -

6 brown green LED

7 -

8 -

9 -

10 purple Card Present

Tab. 7.20: Wiegand interface W3

1 green LED

2 red LED

3 Data 0

4 Data 1

5 -

6 Reader Supply (0V)

7 Reader Supply (8V - 30V)DC

8 -

9 -

10 -

Tab. 7.21: Wiegand interface W4

Notice!For reader settings refer to the respective reader manual.

1 Reader Supply (12V)

2 Reader Supply (0V)

3 Data

4 Data clock

5 Shield

6 green LED

7 red LED

8 Beeper

Page 115: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Appendices | en 115

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

9 Hold

10 Card Present

Tab. 7.22: Omron interface

Page 116: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

116 en | Appendices Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

1 Reader Supply (10V - 30V)

2 Reader Supply (0V)

3 Shield

4 Data RxTx+

5 Data RxTx-

6 Data shield (PAG)

7 not connected

8 not connected

9 not connected

10 not connected

Tab. 7.23: RS-485 reader interface

1 Reader Supply (12V)

2 Reader Supply (0V)

3 Shield (RI)

4 Data terminal ready (DTR)

5 Clear to Send (CTS)

6 Transmit Data (TxD)

7 Request to Send (RTS)

8 Receive Data (RxD)

9 Dataset Ready (DSR)

10 Data Carrier Detected (DCD)

Tab. 7.24: RS-232 interface

1 Data TxD

2 Data RxD

3 GND

Tab. 7.25: RS-232 interface

1 Analog Input, in

2 Analog Input, out

Tab. 7.26: Analog input

1 Relay Output, normally open

2 Relay Output, common

3 Relay Output, normally closed

Tab. 7.27: Relay output

Page 117: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Appendices | en 117

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

1 Power supply for external devices (10V -30V)

2 Power supply for external devices (0V)

3 Shield

4 Data RxTx+

5 Data RxTx-

6 Ground (PAG)

Tab. 7.28: Host / Extension interface

1 Tamper Contact, in

2 Tamper Contact, out

Tab. 7.29: External tamper contact

Page 118: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

118 en | Appendices Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

Page 119: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Appendices | en 119

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Page 120: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

120 en | Index Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.

IndexAadressing  68

Ccabling  40characteristics  26

DDauerlast  51description  9

16 I/O-board  9, 1416 I-board  168 I/O-board  15

DIL  17, 18, 26, 61, 62, 63display  90

Eequipment  18Ethenet host interface  18Ethernet host interface  26Ethernet interface  53extension interface  45, 98, 99extension interfade  65

Ggrounding  42

Hhost interfaces  18, 21, 26, 43, 55, 97

II/O board  65inputs  21, 26, 82, 98interfaces

Ethernet  92extension  45, 98, 99host  18, 26, 43, 53, 55, 60, 97reader  21, 26, 69, 73, 98RS-232  73RS-485  72

interfadesextension  65

LLCD  90

Mmounting  33

Ooffline capability  11opening  36outputs  21, 26, 75, 98overview  27

Ppower supply  41, 46, 47

Rreader interfaces  21, 26, 69, 72, 98

Wiegand  69resetting  94resistor  84RS-232 host interface  18, 26, 60RS-485 host interface  18, 21, 26, 55

four wire  59two wire  57

Sshielding  42system overview  27

Ttamper  87transfer rates  26, 97

Uunmounting  34

Page 121: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

Access Modular Controller 2 Index | 121

Bosch Access Systems V.B. Installation manual 2020-01 | V02 |

Page 122: Access Modular Controller 2 - Bosch Security and Safety … ·  · 2020-04-13Access Modular Controller 2 3 Table of contents | en Bosch Access Systems V.B. Installation manual 2020-01

122 | Index Access Modular Controller 2

2020-01 | V02 | Installation manual Bosch Access Systems V.B.