Sol
ar in
stal
lati
ons
8
www.dedietrich-heating.com198
Accessories for solar systems
accessOries and OptiOns "sOlar circuits" ➪ independent cOntrOl units
SOL PLUS, SOL AEL control units control solar heating systems with 1 or 2 solar calorifiers, or even 1 calorifier and 1 swimming pool. They only manage the solar circuit; back-up or secondary circuits have to be controlled either by the boiler control unit or by an external control unit, such as DIEMATIC VM iSystem.
Description of the various solar control units Package Ref.
SOL AELFor controlling a solar installation with 1 calorifier fitted with 1 exchanger. Delivered with 2 sensors (TC and TS). The unit is able to control the heating/electrical back-up.
ER708 7630421
SOL PLUS
For controlling a solar water heater with calorifier fitted with 1 or 2 exchanger enabling heating zone reversal (e.g. TRIO) or a combined solar heating system with 3-way boiler return relief valve on the heating return circuits. Delivered with 3 sensors (TC, TS and TR).
ER709 7630422
Options for solar control unit Package Ref.EC173 EC 171 EC 155 Sensor
- PT 1000 dip sensor- PT 1000 contact sensor- PT 1000 collector sensor
EC173EC171EC155
100004651100003690100008011
Connecting kit (PWM) for a 2 solar pumpsAllows the connection of a second solar pump on the SOL PLUS control system.(installation with 2 tanks or 2 x East/west colelctor fields.
ER712 7630423
ModBUS connecting cable (3m)For connection between a SOL PLUS control system and a DIEMATIC iSystem control panel.
ER713 7630424
Lightning conductor unit for SOL control system (to be fitted to the collector on the solar sensor circuit). EC176 89804816
8980
Q27
9D
B_Q
0003
SOL_
Q00
01SO
L_Q
0003
SOL_
Q00
02
Sol
ar in
stal
lati
ons
8
199www.dedietrich-heating.com
➪ hydraulic OptiOns fOr sOlar statiOn
Package Ref.Solar station➪ for fitting to the solar calorifier or on wall:
• SKP 7-8 (system for DHW production)For a maximum of 8 m2 of collectors (manometric height of the solar pump: 7 m) Option of including a SOL PLUS control unit• DKSL 6-8 MSB (system for DHW production)For a maximum of 8 m2 of collectors (manometric height of the solar pump: 7 m) These solar station is fitted with all the components required for the optimal operation of the solar installation: solar pump, non return valves, safety valve, manometer, air/water separator with manual air vent, filing and draining system, thermometers, a flow indicator…Option of including a SOL AEL and SOL PLUS control unit• Tube kit for DKSL 6-8 MSB station assembly on BSL/BESL… N
➪ for wall assembly:• SKS 13-45 (system for DHW production and/or heating back-up)For a maximum of 40 m2 of collectors (manometric height of the solar pump 13 m)These solar station is fitted with all the components required for the optimal operation of the solar installation: solar pump, non return valves, safety valve, manometer, air/water separator with manual air vent, filing and draining system, thermometers, a flow indicator…Possibility to include a SOL PLUS control unit.
ER655
ER710
ER414
ER665
7624853
7630417
100019423
7619964
3-way valve 3/4”3-way 3/4” valve for 2 circuits with SOL PLUS control unit.
EC164 89804803
Kit 2 with 2 valves + sensorFor controlling a solar circuit with 2 collectors fields (East/West) with SOL PLUS control unit.
EC432 100011341
8980
Q24
089
80Q
260
DUO-Tube DUO-flex
8980
Q25
189
80Q
072
EG374/EG 375
EG376
8980
Q07
1
8980
Q03
7
8980
Q03
8EG109EG110
Accessories for solar systems
SK_Q
0001
8980
Q31
089
80Q
303
8980
Q30
5
SKP 7-8
DKSL 6-8 MSB ER414
SKS 13-45
Double, pre-insulated “DUO-TUBE” or “DUO-FLEX” pipes with UV protection and cable for sensor (bicone connectors are to be ordered separately):- Duo-Tube Cu 10 x 10 m- Duo-Tube Cu 15 x 10 m- Duo-Tube Cu 15 x 15 m- Duo-Tube Cu 18 x 15 m- Duo Flex in ribbed stainless steel Ø 16 x 15 m (with easyclic connection)- Duo Flex in ribbed stainless steel Ø 20 x 15 m (with easyclic connection)- Duo Flex in ribbed stainless steel Ø 20 x 20 m (with easyclic connection) Set of collars “Duo-Tube” and "Duo-Flex"- for Duo-Tube Cu 15 and Duo-Flex Ø 16mm, 4 parts- for Duo-Tube Cu 18 and Duo-Flex Ø 20mm, 4 partsSet of bicone connectors for “Duo-tube” or “Duo-Flex” (without soldering)- Set of 2 bicone connectors Ø 15mm (for Duo-tube)- Set of 2 bicone connectors Ø 18mm (for Duo-tube)- Set of 2 bicone connectors Ø 15/18mm (for Duo-tube and Duo-Flex)
ER319EG106EG107EG108EG422EG423EG424
EG109EG110
EG374EG375EG376
100020297
898070008980700189807002
764821776482187648219
8980700389807004
100000417100000418100000419
Expansion vessels- 18 litres- 25 litres- 40 litres- 80 litresWall bracket for expansion vessel up to 25 litres
EG117EG118EG83EG84EC118
100019427100019428
898077728980777389807238
Sol
ar in
stal
lati
ons
8
www.dedietrich-heating.com200
Accessories for solar systems
Package Ref.Differential control system MCDB
Differential control system used to load 1 DHW calorifier from a buffer volume (solar or wood-fired boiler) or transfer energy from one storage tank to another and vice versa (delivered with 3 sensors).
EC162 100004650
A
En
BCDEFG
Ae e
y a
r i g νεργεια
PICTO_ENERGIE_A-A
DMCDB
Energy transfer station from one buffer tank to another and vice versa. Is fitted with2 pumps with energy efficiency index EEI < 0.23 and a 3-way valve; its design allows it to be connected directly to both tanks.
ER468 7604939
8980
Q03
5
8980
F243
8980F243
MCDB
MCDB
DMCDB
accessOries and OptiOns "Water circuit (secOndary)"
heat transfer fluid - accessOries maintenance sOlar circuit
➪ accessOries fOr lOad and unlOad tank
➪ differential cOntrOl system
8980
Q31
4A89
80Q
039
Package Ref.Heat transfer fluid- Pre-mix type L 60/40, 20 litres- “High performance” pre-mix type LS, 20 litres- Pre-mix "BIO" type LR 25, 20 litres (-30°C)
EG101EG100ER316
8980779489807792
100017611
Miscellaneous- Filling station with pump and jerrican- Hand pump for fluid back-up- Antifreeze protection tester (for checking the heat transfer fluid)- Measuring box with refractometer- Check box for solar installation- Cleaning material for solar circuit SolRnet
EG81EG80EG102EG104ER50ER318
89807770898077698980779789807799
100012031100020025
Package Ref.Differential control system SLA 2- to control the temperature of an independent tank combined
with a boiler without control system, a storage tank with wood-fired boiler, or a solar storage tank,
- to monitor the heating return and bypass the solar tank if the return temperature is higher than the temperature in the solar tank.
Delivered with 3 sensors.
EC320 100007832
8980
Q03
5
8980
F352
8980F352
SLA 2
8980
Q03
389
80Q
08389
80Q
091
EG81 EG80
EG102
8980
Q08
5
EG104