+ All Categories
Home > Documents > Accessories for the Laser Scattering Particle Size ......[Measurement range] 0.01–1000 μm, suits...

Accessories for the Laser Scattering Particle Size ......[Measurement range] 0.01–1000 μm, suits...

Date post: 09-Jul-2020
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
2
Partica LA-960V2 solves your problems. Ideal for these situations: Observe distributions at high concentration without diluting the material High viscosity Low viscosity High-Concentration Cell The High-Concentration Cell is able to measure close to original concentration with low dilution or without dilution. Dry Measurement Unit The Dry Measurement Unit can measure samples in a powder state. It supports both non-dispersed measurement by free fall and forced-dispersion measurement using compressed air. Automatic Sampler (Wet measurement in powder) The Auto Sampler is a rotary table-type automatic sampling system equipped with 24 detachable sample cups. Change cells just by sliding the changer table. No tools needed. MiniFlow Circulation System The MiniFlow can measure samples of dispersion medium as small as 35 mL. Recommended when using organic solvent as a dispersant. The MiniFlow comes with an ultrasonic probe and automatic dispersant feeding pump as standard. Fraction Cell The Fraction Cell can take measurement with samples as small as only 5 mL, minimize the amount of dispersant. The Fraction Cell is ideal when the sample is extremely small or you need to recover the entire sample. [Measurement range] 0.01–1000 μm, suits organic solvents Cell volumes: 5 mL, 10 mL, 15 mL Paste Cell The Paste Cell can measure undiluted samples or samples dispersed in a viscous medium. Measure without dilution Inks, paints, pigments, emulsions Positive and negative electrode materials of secondary batteries etc. Observe changes in the agglomeration state based on concentration etc. Agglomerated was found when a battery was measured near to original concentration Food materials, drugs, washing powder, and other samples easily soluble in water Granules and granulated powder formed by agglomerating and processing particles Polymers and resins that swell when dispersed in water or solvent Powders with water-repellent coating Pigments, paints, stationery inks, and other samples dispersed in organic solvent Drugs, food, dyes, and other water-soluble samples and dispersed in organic solvent Fuels, lubricants, and other samples dispersed in an oil solvent Rare sample Measurements with highly volatile solvent Microparticles dispersed in high-viscosity samples or polymers Magnetic powder: Measure magnetic powder by dispersing it in viscous oil to prevent re-agglomeration. LA-960V2 Accessories for the Laser Scattering Particle Size Distribution Analyzer Easy cell switching. Laser light Vacuum sampler The vacuum sampler is able to measure a very small amount of sample. Coated chute The chute is coated with an electroplated nickel fluoride resin. For samples that adhere easily to a stainless steel chute and it is difficult to feed the sample by vibration. Measure both agglomerated and granulated powder without destroying them Measure small samples Measure multiple samples automatically 0.010 Frequency (%) 0 5 10 15 20 24 Particle size (μm) 0.100 1.000 10.00 100.0 Median size 0.09538 (μm) 0.08798 (μm) Data name Undiluted sample Flow measurement The peak of the agglomerated sample is detected by measuring undiluted suspension. Comparison of the results of undiluted suspension measurement and flow measurement (diluted with dispersant) Laser Scattering Particle Size Distribution Analyzer Partica LA-960V2 Series Accessories & Unique Features NEW
Transcript
Page 1: Accessories for the Laser Scattering Particle Size ......[Measurement range] 0.01–1000 μm, suits organic solvents Cell volumes: 5 mL, 10 mL, 15 mL Paste Cell The Paste Cell can

Partica LA-960V2 solves your problems.Ideal for these situations:

Observe distributions at high concentration

without diluting the material

High viscosity

Low viscosity

High-Concentration CellThe High-Concentration Cell is able to measure close to original concentration with low dilution or without dilution.

Dry Measurement UnitThe Dry Measurement Unit can measure samples in a powder state.It supports both non-dispersed measurement by free fall and forced-dispersion measurement using compressed air.

Automatic Sampler(Wet measurement in powder)

The Auto Sampler is a rotary table-type automatic sampling system equipped with 24 detachable sample cups.

Change cells just by sliding the changer table. No tools needed.

MiniFlow Circulation SystemThe MiniFlow can measure samples of dispersion medium as small as 35 mL. Recommended when using organic solvent as a dispersant.The MiniFlow comes with an ultrasonic probe and automatic dispersant feeding pump as standard.

Fraction CellThe Fraction Cell can take measurement with samples as small as only 5 mL, minimize the amount of dispersant.The Fraction Cell is ideal when the sample is extremely small or you need to recover the entire sample.

[Measurement range] 0.01–1000 μm, suits organic solvents

Cell volumes: 5 mL, 10 mL, 15 mL

Paste CellThe Paste Cell can measure undiluted samples or samples dispersed in a viscous medium.

Measure without dilution Inks, paints, pigments, emulsions

Positive and negative electrode materials of secondary batteries etc.

Observe changes in the agglomeration state based on concentration etc.

Agglomerated was found when a battery was measured near to original concentration

Food materials, drugs, washing powder, and other samples easily soluble in water

Granules and granulated powder formed by agglomerating and processing particles

Polymers and resins that swell when dispersed in water or solvent

Powders with water-repellent coating

Pigments, paints, stationery inks, and other samples dispersed in organic solvent

Drugs, food, dyes, and other water-soluble samples and dispersed in organic solvent

Fuels, lubricants, and other samples dispersed in an oil solvent

Rare sample Measurements with highly volatile solvent

Microparticles dispersed in high-viscosity samples or polymers

Magnetic powder: Measure magnetic powder by dispersing it in viscous oil to prevent re-agglomeration.

LA-960V2Accessories for the Laser Scattering Particle Size Distribution Analyzer

Easy cell switching.

Laser light

● Vacuum samplerThe vacuum sampler is able to measure a very small amount of sample.

● Coated chuteThe chute is coated with an electroplated nickel fluoride resin. For samples that adhere easily to a stainless steel chute and it is difficult to feed the sample by vibration.

Measure both agglomerated and granulated powder

without destroying themMeasure small samples

Measure multiple samples automatically

0.010

Freq

uenc

y (%

)

0

5

10

15

20

24

Particle size (μm)0.100 1.000 10.00 100.0

Median size0.09538 (μm)0.08798 (μm)

Data nameUndiluted sampleFlow measurement

The peak of the agglomerated sample is detected by measuring undiluted suspension.

Comparison of the results of undiluted suspension measurement and flow measurement (diluted with dispersant)

Laser Scattering Particle Size Distribution Analyzer

Partica LA-960V2 SeriesAccessories & Unique Features

NEW

Page 2: Accessories for the Laser Scattering Particle Size ......[Measurement range] 0.01–1000 μm, suits organic solvents Cell volumes: 5 mL, 10 mL, 15 mL Paste Cell The Paste Cell can

Flexible dispersion conditions: forced dispersion or non-dispersion measurement

Sample AirAir

Compressed air

Air guidance plates

Laser

Cell window

Vacuum

22 100

50

0

15

10

0.100 1.000 10.00 100.0 1000 5000

Freq

uenc

y (%

)

Tota

l pas

sage

am

ount

(%)

5

0

Particle size (μm)

22 100

50

0

15

10

0.100 1.000 10.00 100.0 1000 5000

5

0

Freq

uenc

y (%

)

Tota

l pas

sage

am

ount

(%)

Particle size (μm)

Median size930.03 (μm)691.25 (μm)

Data namew/o compressed airw/ compressed air (0.4 MPa)

Median size930.03 (μm)964.26 (μm)

Data nameVacuum samplerStandard chute

High-Concentration Cell

Optical microscope image

Granulated powder measurement results (w/ and w/o compressed air)

Example of particle-size distribution measurement (with High-Concentration Cell)

Granulated powder measurement results (w/o compressed air and w/ vacuum sampler)

MiniFlow(Circulation system)

0.0100

5

10

15

0

20

40

60

80

100

0.100 1.000 10.00 100.0 1000 3000

Freq

uenc

y (%

)

Tota

l pas

sage

am

ount

(%)

Particle size (μm)

0 0

50

100

5

10

20

15

0.010 0.100 1.000 10.00 100.0 1000 5000

Freq

uenc

y (%

)

Tota

l pas

sage

am

ount

(%)

Particle size (μm)

0 0

50

100

5

10

20

15

0.010 0.100 1.000 10.00 100.0 1000 5000

Freq

uenc

y (%

)

Tota

l pas

sage

am

ount

(%)

Particle size (μm)

0 0

50

100

5

10

20

15

0.010 0.100 1.000 10.00 100.0 1000 5000

Freq

uenc

y (%

)

Tota

l pas

sage

am

ount

(%)

Particle size (μm)

w/o ultrasonic Ultrasonic 3 min

Ultrasonic 5 min

● Dry measurement allows measurement in powder state without dispersants.● Dispersion with compressed air can be deactivated, so it is possible to measure fragile sample

such as granules and granulated powder.

● High concentration cell can be used to measure particle size distribution and also can be set up under an optical microscope in the same condition.

● Measurement needs as small as 35 mL of solvent (180 mL with conventional circulation systems).● Dispersion is possible with the built-in ultrasonic probe.

Example of dry-measuring granulated powder

Example of dispersion evaluation of carbon black (with MiniFlow)

Particles are destroyed if exposed to compressed air.

Measurement possible without destroying granulated powder using any type of chute

Multiple observations under the same conditions

Small-volume circulation with organic solvents

This

doc

umen

t is

not c

ontra

ctua

lly b

indi

ng u

nder

any

circ

umst

ance

s - P

rinte

d in

Jap

an -

©H

OR

IBA

Scie

ntifi

c 2/

2019

[email protected] www.horiba.com/scientific

Vietnum: +84 (24)3795 8552

China: +86 (21) 6289 6060 India: +91 (80) 4127 3637

France: +33 (1) 69 74 72 00 Japan: +81(75)313-8121

Korea: +82 (31) 296 7911 Singapore: +65 (6) 745-8300

Germany: +49 (89) 62 51 84 750 Americas: +1 732 494 8660

Taiwan: +886 (3) 560-0606 Thailand: +66 (0)2 861 5995

Other: +81(75)313-8121Bulletin: HRE-3690A