105
Delivering the Moment Installation and Operaon Manual Neo® ACO-3901 Automac Changeover Unit Edion E 175-000190-00
Transcript
Page 1: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Delivering the Moment

Installation and Operation Manual

Neo® ACO-3901 Automatic Changeover Unit

Edition E

175-000190-00

Page 2: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Publication Information © 2014 Imagine Communications Corp. Proprietary and Confidential.

Imagine Communications considers this document and its contents to be proprietary and confidential. Except for making a reasonable number of copies for your own internal use, you may not reproduce this publication, or any part thereof, in any form, by any method, for any purpose, or in any language other than English without the written consent of Imagine Communications. All others uses are illegal.

This publication is designed to assist in the use of the product as it exists on the date of publication of this manual, and may not reflect the product at the current time or an unknown time in the future. This publication does not in any way warrant description accuracy or guarantee the use for the product to which it refers. Imagine Communications reserves the right, without notice to make such changes in equipment, design, specifications, components, or documentation as progress may warrant to improve the performance of the product.

Trademarks 6800+™, ADC™, CCS Navigator™, Channel ONE™, ChannelView™, ClipSync™, Delay™, D Series™, D Series DSX™, Deliver the Moment™, Delivering the Moment™, FAME™, Farad™, G8™, G Scribe™, HView™, IconMaster™, IconLogo™, IconSta-tion™, IconKey™, InfoCaster™, InfoCaster Creator™, InfoCaster Manager™, InfoCaster Player™, InstantOnline™, Invenio®, Live Update™, mCAPTURE™, Magellan™, Magellan CCS Navigator™, Magellan Q SEE™, MultiService SDN™, NetPlus™, NetVX™, NewsForce™, Nexio® G8™, Nexio AMP® ChannelView™, Nexio® Channel ONE™, Nexio® ClipSync™, Nexio® Delay™, Nexio® Digital Turnaround Processor™, Nexio® Farad™, Nexio® G Scribe™, Nexio® IconKey™, Nexio® IconLogo™, Nexio® IconMaster™, Nexio® IconStation™, Nexio® InfoCaster™, Nexio® InfoCaster Creator™, Nexio® InfoCaster Manag-er™, Nexio® InfoCaster Player™, Nexio® InfoCaster Traffic™, Nexio® InstantOnline™, Nexio® mCAPTURE™, Nexio® News-Force™, Nexio® NXIQ™, Nexio® Playlist™, Nexio® Remote™, Nexio®RTX Net™, Nexio® TitleMotion™, Nexio® TitleOne™, Nexio® Velocity ESX™, Nexio® Velocity PRX™, Nexio® Velocity XNG™, Nexio® Volt™, OPTO+™, Panacea™, Platinum™, Playlist™, Predator II GRF™, Predator II GX™, Punctuate™, Remote™, RTX Net™, QuiC™, Q SEE™, SD STAR™, Selenio™, Selenio 6800+™, SelenioNext™, Selenio X50™, Selenio X85™, Selenio X100™, TitleMotion™, TitleOne™, Velocity ESX™, Velocity PRX™, Velocity XNG™, Versio™, Videotek® SD STAR™, X50™, and X85™ are trademarks of Imagine Communica-tions or its subsidiaries.

Altitude Express®, Connectus®, Enabling PersonalizedTV®, ICE® Broadcast System, ICE Illustrate®, ICE Q® algorithms, ICE-PAC®, Imagine ICE®, Inscriber®, Inscriber® Connectus®, Invenio®, NEO®, Nexio®, Nexio AMP®, PersonalizedTV®, Router-Works®, Videotek®, Videotek® ASI STAR®, Videotek® GEN STAR®, and Videotek® HD STAR® are registered trademarks of Imagine Communications or its subsidiaries.

Microsoft® and Windows® are registered trademarks of Microsoft Corporation. HD BNC is a trademark of Amphenol Corporation. Some products are manufactured under license from Dolby Laboratories. Dolby and the double D symbol are registered trademarks of Dolby Laboratories. DTS Neural audio products are manufactured under license from DTS Licensing Limited. DTS and the Symbol are registered trademarks & the DTS Logos are trademarks of DTS, Inc. © 2008 2010 DTS, Inc. All other trademarks and trade names are the property of their respective companies.

Contact Information Imagine Communications has office locations around the world. For locations and contact information see: http://www.imaginecommunications.com/contact us/

Support Contact Information For support contact information see:

Support Contacts: http://www.imaginecommunications.com/services/technical support/ eCustomer Portal: http://support.imaginecommunications.com

© 2014 Imagine Communications Corp. Proprietary and Confidential

Page 3: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

1 of 1/December 2006

175-000190-00

Addendum

ACO-3901 Automatic Changeover Unit Installation and Operation Manual

About This DocumentThis document adds information to the ACO-3901 Automatic Changeover Unit Installation and Operation Manual, Edition E about using an external power supply with the ACO-3901.

Connecting the External Power SupplyOn page 23 of the ACO-3901 Automatic Changeover Unit Installation and Operation Manual, Edition E, the following warning information should appear under “Connecting the External Power Supply”:

WarningTo prevent your modules from overheating (and causing irreversible damage to module components), do not use the external power supply to provide power to the ACO-3901 for extended periods of time. The power supply only provides electricity to the modules, but not the frame. The fans in the frame do not operate if the frame’s power supply fails.

Page 4: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and
Page 5: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Edition ENovember 2006

ACO-3901Automatic Changeover Unit

Installation and Operation Manual

Page 6: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Trademarks and CopyrightsCCS, CCS CoPilot, CCS Navigator, CCS Pilot, Command Control System, CineTone, CinePhase, CineSound, DigiBus, DigiPeek, Digital Glue, DigiWorks, DTV Glue, EventWORKS, EZ HD, Genesis, HDTV Glue, Image Q, Icon, IconLogo, IconMaster, IconMaster Nav, IconSet, IconStation, Inca, Inca Station, InfoCaster, Inscriber, Inscriber CG—FX, Integrator, LeFont, Leitch, LogoMotion, MediaFile, MIX BOX, NEO, the NEO design, NEOSCOPE, NewsFlash, Nexio, Opus, Panacea, PanelMAPPER, Portal, PROM-Slide, RouterMAPPER, RouterWORKS, Signal Quality Manager, SpyderWeb, SuiteView, TitleMotion, UNIFRAME, Velocity, VelocityHD, VideoCarte, Videotek, and X75 are trademarks of Leitch Technology International Inc. which may be registered in the United States, Canada, and/or other countries. All other trademarks are the property of their respective owners.Copyright 2006, Leitch Technology International Inc. All rights reserved. This publication supersedes all previous releases. Printed in Canada.

Warranty InformationThe Limited Warranty Policy provides a complete description of your warranty coverage, limitations, and exclusions, as well as procedures for obtaining warranty service. To view the complete warranty, visit www.broadcast.harris.com/leitch.

Page 7: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Contents

PrefaceManual Information .............................................................................. vii

Purpose ........................................................................................... viiAudience ........................................................................................ viiRevision History ............................................................................ vii

Third-Party Software Licensing Agreement .......................................... ixWriting Conventions .........................................................................xObtaining Documents .......................................................................x

Unpacking/Shipping Information .......................................................... xiUnpacking a Product ....................................................................... xiProduct Servicing ............................................................................ xiReturning a Product ........................................................................ xi

Restriction on Hazardous Substances (RoHS) Compliance ................. xiiWaste from Electrical and Electronic Equipment(WEEE) Compliance ............................................................................ xiiiSafety ................................................................................................... xiv

Safety Terms and Symbols in this Manual ................................... xiv

Chapter 1: IntroductionOverview ..................................................................................................1Product Description ..................................................................................2

Overview ...........................................................................................2Main Features ...................................................................................2

Front, Rear, and Back Modules ...............................................................3Module Alignment ............................................................................3

Signal Flow ..............................................................................................9

ACO-3901 Installation and Operation Manual iii

Page 8: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Contents

Chapter 2: Installation and RemovalOverview ............................................................................................... 11Packing List ........................................................................................... 12Setting Jumpers ..................................................................................... 13

Input and Output Impedance on the ACO-3901-FM ..................... 13Default Input on the ACO-3901-RM ............................................. 15Telco Line on the ACO-3901-BM ................................................. 17

Installing the ACO-3901 Modules ........................................................ 19Connecting the Input Sources ............................................................... 22

MTG-3901 Modules ...................................................................... 22External Input Source ..................................................................... 22

Connecting the External Power Supply ................................................ 23Removing ACO-3901 Modules ............................................................ 23Upgrading ACO-3901 Firmware .......................................................... 24

Upgrading Procedure ..................................................................... 24Correcting a Failed Upgrading Procedure ..................................... 28

Chapter 3: OperationOverview ............................................................................................... 33Operation Notes ..................................................................................... 34GPO Pinouts .......................................................................................... 34Cross-Functional Parameter Changes ................................................... 36Navigating the Operator and All Lists .................................................. 39Operator and All List Parameters .......................................................... 40Setup Parameters ................................................................................... 56Alarms ................................................................................................... 57

CCS-Enabled Alarms ..................................................................... 57Hardware Alarms ........................................................................... 61

State Recovery Parameter Availability ................................................. 62LED and Module Indicators .................................................................. 63

General Information ....................................................................... 63Card-Edge Locations ...................................................................... 64LED Descriptions ........................................................................... 65Module Indicators Descriptions ..................................................... 66

iv ACO-3901 Installation and Operation Manual

Page 9: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Contents

Chapter 4: SpecificationsOverview ................................................................................................67Input .......................................................................................................68

Analog Video Input ........................................................................68DARS Input ....................................................................................68Hz Input ..........................................................................................68LTC Input .......................................................................................69

Output .....................................................................................................70Analog Video Output ......................................................................70DARS (Unbalanced) Output ...........................................................70LTC Output .....................................................................................70

Miscellaneous .........................................................................................71Changeover Threshold ....................................................................71Isolation ..........................................................................................71Power Consumption ........................................................................71

Appendix A: Tree-View NavigationOverview ................................................................................................73Navigating the Tree View ......................................................................74Tree View Parameters ............................................................................75

IndexKeywords ...............................................................................................83

ACO-3901 Installation and Operation Manual v

Page 10: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Contents

vi ACO-3901 Installation and Operation Manual

Page 11: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Preface

Manual Information

PurposeThis manual details the features, installation, operation, maintenance, and specifications of the NEO ACO-3901 Automatic Changeover Unit.

AudienceThis manual is written for engineers, technicians, and operators responsible for the installation, setup, maintenance, and operation of the NEO ACO-3901 Automatic Changeover Unit.

Revision History

Table P-1. Revision History

Edition Date Revision HistoryA April 2004 Initial release

B June 2004 Minor updates

ACO-3901 Installation and Operation Manual vii

Page 12: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Preface

C November 2004 Parameter name changes and updates, and the addition of cross-functional parameter change information

D October 2005 Revisions of product codes, GPO pinout parameter changes, and manual template updates

E November 2006 Addition of addendum and errata information from previous edition of the manual

Table P-1. Revision History

Edition Date Revision History

viii ACO-3901 Installation and Operation Manual

Page 13: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Preface

Third-Party Software Licensing AgreementIf the software embedded in a product incorporates the VxWorks Run-Time Module, the following paragraphs are applicable:You are prohibited from:a) copying the Run-Time Module, except for archive purposes consistent with your archive procedures;b) transferring the Run-Time Module to a third party apart from the product containing the Run-Time Module;c) modifying, decompiling, disassembling, reverse engineering or otherwise attempting to derive the source code of the Run-Time Module;d) exporting the Run-Time Module of underlying technology in contravention of applicable U.S. and foreign export laws and regulations, ande) using the Run-Time Module other than in connection with operation of the product in which it is embedded.Any further distribution of the Run-Time Module is subject to the same restrictions set forth herein. Wind River Systems, Inc. and its licensors are third party beneficiaries of the End User License Agreement and the provisions related to the Run-Time Module are made expressly for the benefit of, and are enforceable by, Wind River Systems, Inc. and its licensors.The laws of the Province of Ontario shall govern this Agreement. Updated January, 2005.

ACO-3901 Installation and Operation Manual ix

Page 14: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Preface

Writing ConventionsTo enhance your understanding, the authors of this manual have adhered to the following text conventions:

Obtaining DocumentsProduct support documents can be viewed or downloaded from our Web site at www.broadcast.harris.com/leitch (go to Support> Documentation). Alternatively, contact your customer service representative to request a document.

Table P-2. Writing Conventions

Term or Convention Description

Bold Indicates dialog boxes, property sheets, fields, buttons, check boxes, list boxes, combo boxes, menus, submenus, windows, lists, and selection names

Italics Indicates E-mail addresses, the names of books or publications, and the first instances of new terms and specialized words that need emphasis

CAPS Indicates a specific key on the keyboard, such as ENTER, TAB, CTRL, ALT, or DELETE

Code Indicates variables or command-line entries, such as a DOS entry or something you type into a field

> Indicates the direction of navigation through a hierarchy of menus and windows

hyperlink Indicates a jump to another location within the electronic document or elsewhere

Internet address Indicates a jump to a Web site or URL

NoteIndicates important information that helps to avoid and troubleshoot problems

x ACO-3901 Installation and Operation Manual

Page 15: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Preface

Unpacking/Shipping InformationUnpacking a Product

This product was carefully inspected, tested, and calibrated before shipment to ensure years of stable and trouble-free service. 1. Check equipment for any visible damage that may have occurred

during transit. 2. Confirm that you have received all items listed on the packing list. 3. Contact your dealer if any item on the packing list is missing.4. Contact the carrier if any item is damaged.5. Remove all packaging material from the product and its associated

components before you install the unit.Keep at least one set of original packaging, in the event that you need to return a product for servicing.

Product ServicingACO-3901 are not designed for field servicing. All upgrades, modifications, or repairs require you to return the product to the Customer Service center.

Returning a ProductIn the unlikely event that your product fails to operate properly, please contact Customer Service to obtain a Return Authorization (RA) number, then send the unit back for servicing. Keep at least one set of original packaging in the event that a product needs to be returned for service. If the original package is not available, you can supply your own packaging as long as it meets the following criteria:• The packaging must be able to withstand the product’s weight.• The product must be held rigid within the packaging.• There must be at least 2 in. (5 cm) of space between the product and

the container.• The corners of the product must be protected.Ship products back to us for servicing prepaid and, if possible, in the original packaging material. If the product is still within the warranty period, we will return the product prepaid after servicing.

ACO-3901 Installation and Operation Manual xi

Page 16: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Preface

Restriction on Hazardous Substances (RoHS) Compliance

Directive 2002/95/EC—commonly known as the European Union (EU) Restriction on Hazardous Substances (RoHS)—sets limits on the use of certain substances found in electrical and electronic equipment. The intent of this legislation is to reduce the amount of hazardous chemicals that may leach out of landfill sites or otherwise contaminate the environment during end-of-life recycling. The Directive takes effect on July 1, 2006, and it refers to the following hazardous substances: • Lead (Pb)• Mercury (Hg)• Cadmium (Cd)• Hexavalent Chromium (Cr-V1)• Polybrominated Biphenyls (PBB)• Polybrominated Diphenyl Ethers (PBDE)According to this EU Directive, all products sold in the European Union will be fully RoHS-compliant and “lead-free.” (See our Web site, www.broadcast.harris.com/leitch, for more information on dates and deadlines for compliance.) Spare parts supplied for the repair and upgrade of equipment sold before July 1, 2006 are exempt from the legislation. Equipment that complies with the EU directive will be marked with a RoHS-compliant emblem, as shown in Figure P-1.

Figure P-1. RoHS Compliance Emblem

xii ACO-3901 Installation and Operation Manual

Page 17: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Preface

Waste from Electrical and Electronic Equipment (WEEE) Compliance

The European Union (EU) Directive 2002/96/EC on Waste from Electrical and Electronic Equipment (WEEE) deals with the collection, treatment, recovery, and recycling of electrical and electronic waste products. The objective of the WEEE Directive is to assign the responsibility for the disposal of associated hazardous waste to either the producers or users of these products. Effective August 13, 2005, producers or users will be required to recycle electrical and electronic equipment at end of its useful life, and may not dispose of the equipment in landfills or by using other unapproved methods. (Some EU member states may have different deadlines.)In accordance with this EU Directive, companies selling electric or electronic devices in the EU will affix labels indicating that such products must be properly recycled. (See our Web site, www.broadcast.harris.com/leitch, for more information on dates and deadlines for compliance.) Contact your local sales representative for information on returning these products for recycling. Equipment that complies with the EU directive will be marked with a WEEE-compliant emblem, as shown in Figure P-2.

Figure P-2. WEEE Compliance Emblem

ACO-3901 Installation and Operation Manual xiii

Page 18: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Preface

SafetyCarefully review all safety precautions to avoid injury and prevent damage to this product or any products connected to it. If this product is rack-mountable, it should be mounted in an appropriate rack using the rack-mounting positions and rear support guides provided. It is recommended that each frame be connected to a separate electrical circuit for protection against circuit overloading. If this product relies on forced air cooling, it is recommended that all obstructions to the air flow be removed prior to mounting the frame in the rack. If this product has a provision for external earth grounding, it is recommended that the frame be grounded to earth via the protective earth ground on the rear panel.IMPORTANT! Only qualified personnel should perform service procedures.

Safety Terms and Symbols in this ManualWARNINGStatements identifying conditions or practices that may result in personal injury or loss of life. High voltage is present.

CAUTIONStatements identifying conditions or practices that can result in damage to the equipment or other property.

xiv ACO-3901 Installation and Operation Manual

Page 19: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 1

Introduction

OverviewThe NEO ACO-3901 group of modules combine to create a non-generic automatic changeover unit designed to support MTG-3901 and CSD-3902 inputs. The unique design of the product includes a front module, an extended three-slot back module, and a rear module that bridges between the back and front modules. This chapter covers the following topics:• “Product Description” on page 2• “Front, Rear, and Back Modules” on page 3• “Signal Flow” on page 9See the FR-3901, FR-3903, and FR-3923 Installation and Operation Manual for information about NEO frames. The frame manual includes information about these items: • General information about module unpacking, installation,

removal, navigation, configuration, and setup• Card-edge screen savers• State recovery parameters• Fan modules• Resource modules• Alarm interconnect modules• Power supplies• Servicing instructions

NoteInstallation, navigation, configuration, and setup information for NEO modules is now included in the NEO FR-3901, FR-3903, and FR-3923 Mounting Frames Installation and Operation Manual. If your current NEO frame manual is Edition A, B, C, or D, you will need to download an updated version from our Web site (www.broadcast.harris.com/leitch) to access this information.

ACO-3901 Installation and Operation Manual 1

Page 20: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 1: Introduction

Product Description

OverviewThe ACO-3901 Automatic Changeover Unit is a non-generic automatic changeover unit that supports two input sources: the MTG-3901 Master Time Generator or the CSD-3902 Clock System Driver. The ACO-3901 provides redundant switching between a primary MTG-3901, a secondary MTG-3901 and an external source (or between a primary CSD-3902, a secondary CSD-3902, and an external source).The switch from primary to secondary inputs can be isolated to a single channel or made globally to the other available channels. Faults in input signals are indicated through front panel LEDs and via an audible alarm, heard on a speaker located on the ACO-3901 front module.In the event of a power failure in the NEO frame, the ACO-3901 automatically switches to the external 24 volt source.

Main FeaturesThe ACO-3901 Automatic Changeover Unit has the following features:• Two sets of inputs from two MTG-3901 modules or two CSD-3902

modules• One set of inputs from an external source• Three-module construction, with a front module for active

electronics, a rear card for relays, and a back module for connectivity

• Single-channel or global switching• Automatic switching to backup sources• Automatic switching to 24 volt external power source in the event

of power loss• 24 V DC backup power supply unit• User-configurable fail condition for electrical (threshold) or

legitimate signal (audio, video)• Audio alarm in case of source or power failure• Self-generating failed source outputs error list visible on card-edge,

CCS software, and CCS control panels

2 ACO-3901 Installation and Operation Manual

Page 21: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 1: Introduction

• Ability to synchronize the two MTG-3901 modules (or two CSD-3902 modules) to the external source or to one another

• Ability to perform self-diagnosis (visible on the card-edge, on CCS control panels, and on CCS software applications)

• On-board self-testing for signal monitoring to detect component failure

• Control and monitoring via the card-edge, CCS software applications, and CCS control panels

Front, Rear, and Back Modules

Module AlignmentThe ACO-3901 module’s unique three-piece design includes a front module, an extended three-slot back module, and a rear module that bridges the front and back modules.Figure 1-1 on page 4 shows the alignment of the ACO-3901-FM front, the ACO-3901-RM rear, and the ACO-3901-BM back modules. Front, rear, and back modules are designated by the suffix “-FM”, “RM”, and “-BM” respectively. For example, the front module of the ACO-3901 is the “ACO-3901-FM”.See Figure 1-2 on page 5 for detailed labelling of the ACO-3901-BM back module.

ACO-3901 Installation and Operation Manual 3

Page 22: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 1: Introduction

Front, Rear, and Back Modules

Figure 1-1. ACO-3901-FM, ACO-3901-RM and ACO-3901-BM Modules, Top View

Front Module

Back Module

Rear Module

4 ACO-3901 Installation and Operation Manual

Page 23: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 1: Introduction

Back Module

Figure 1-2. ACO-3901-BM Back Module

Gen

lock

I nG

enlo

ckLo

op

Bac

k

CO

MP

4D

AR

SC

OM

P 3

CO

MP

2C

OM

P 1

HZ

LTC

2 O

utp

uts

& G

PI

+Im

pu

lse

Drv

HZ

LTC

2 In

pu

ts &

GP

I +Im

pu

lse

Drv

Exte

rnal

So

urc

e In

pu

ts

AC

O-3

90

1 O

ut p

uts

AC

O-3

90

1-B

M

24

V- 3

AET

HE

RN

ET 2

10

MH

zP

PS

Telc

o L

ine

ETH

ERN

E T 1

LTC

INR

S-2

32

CO

MP

4D

AR

SC

OM

P 3

CO

MP

2C

OM

P 1

ACO-3901 Installation and Operation Manual 5

Page 24: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 1: Introduction

Back Module Connector PinoutsThe following tables describe the pinouts for the connectors located on the ACO-3901-BM back module. Table 1-1 lists the conductors in the LTC In DB-9 connector. Table 1-2 lists the conductors for the RS-232 port for GPS connections. The conductors in the LTC 2 Outputs & GPI + Impulse Driver DB-15 connector are listed in Table 1-3 on page 7. Table 1-4 on page 8 lists the conductors in the external source LTC 2 Inputs & GPI + Impulse Driver DB-15 connectors.

Table 1-1. MTG Input Pinouts (LTC In DB-9 Connector)

Pin Number Connection1 Gnd

2 Gnd

3 LTC1_IN_N

4 Gnd

5 Gnd

6 LTC1_IN_P

7 Gnd

8 Gnd

9 PPS

Table 1-2. RS-232 Pinouts (GPS DB-9 Connector)

Pin Number Connection1 Received Line Signal Detector (RLSD)

2 Received Data (RD)

3 Transmitted Data (TD)

4 DTE Ready (DTR)

5 Signal Common (GND)

6 DCE Ready (DCR)

7 Request to Send (RTS)

8 Clear to Send (CTS)

9 Ring Indicator (RI)

6 ACO-3901 Installation and Operation Manual

Page 25: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 1: Introduction

*See “GPO Pinouts” on page 34 for more information about configuring GPO_CL1 and GPO_CL2 pinouts.

Table 1-3. Output Pinouts (DB-15 Connector)

Pin Number Connection1 Gnd

2 Imp_OUT_2

3 Gnd

4 Imp_OUT_1

5 Gnd

6 GPO_CL1*

7 GPO_CL2*

8 Gnd

9 LTC2N_OUT

10 Gnd

11 LTC2P_OUT

12 Gnd

13 LTC1N_OUT

14 Gnd

15 LTC1P_OUT

ACO-3901 Installation and Operation Manual 7

Page 26: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 1: Introduction

Table 1-4. External Source Input Pinouts (DB-15 Connector)

Pin Number Connection1 Gnd

2 Ext_LTC1P

3 Gnd

4 Ext_LTC1N

5 Gnd

6 Gnd

7 Ext_LTC2P

8 Gnd

9 Ext_LTC2N

10 Gnd

11 Gnd

12 Ext_Impulse_IN1

13 Gnd

14 Ext_Impulse_IN2

15 Gnd

8 ACO-3901 Installation and Operation Manual

Page 27: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 1: Introduction

Signal Flow

Figure 1-3. ACO-3901 Signal Flow Diagram

AC

O-3

901

(est

. max

. pow

er =

15W

)

SelectorControler

Composite 1

Selector

Con

trol

In #1 In #2

In #

3

Output

Composite 1

Com

posi

te 1

Exte

rnal

sou

rce

(MTG

-390

1 or

CSD

-390

2)

Com

mun

icat

ion

NEO

fram

e

NEO

Res

ourc

eM

odul

e

CC

S so

ftwar

e ap

plic

atio

nge

neric

use

r int

erfa

ce

GL_

BB

GL_

BB

24 V

"Bac

kup

PS"

Exte

rnal

Pow

erSu

pply

70W

@ 2

4V D

C

Com

posi

te4

DA

RS

Hz

Com

posi

te3

Com

posi

te2

Com

posi

te1

Impu

lse

LTC

2LT

C 1

Hz

DARS

Comp 4

Comp 3

Comp 2

Comp 1

LTC 2

ImpulseLTC 1

Com

posi

te 1

Hz

LTC

2LT

C 1

DA

RS

Com

posi

te 4

Com

posi

te 3

Com

posi

te 2

Impu

lse

Com

posi

te 1

Hz

LTC

2LT

C 1

DA

RS

Com

posi

te 4

Com

posi

te 3

Com

posi

te 2

Impu

lse

GPS

LTC

Sou

rce

LTC

in

GL

Sour

ce

BB

in

BB

loop

RS-

232

PPS

10M

Hz

GPS

Ant

enna

Net

wor

k

NTP

Ser

ver

Ethe

rnet

Ethe

rnet

CSD

-390

1

Telc

oM

odem

Leitc

h

CSD

-390

1

MTG

-390

1 #1

(max

imum

pow

er =

20W

)or

CSD

-390

2

MTG

-390

1 #2

(max

imum

pow

er =

20W

)or

CSD

-390

2

24 V

24 V

ACO-3901 Installation and Operation Manual 9

Page 28: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 1: Introduction

10 ACO-3901 Installation and Operation Manual

Page 29: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2

Installation and Removal

OverviewInstallation, navigation, configuration, and setup information is now included in the NEO FR-3901, FR-3903, and FR-3923 Mounting Frames Installation and Operation Manual. If your current NEO frame manual is Edition A, B, C, or D, you will need to download an updated version from our Web site (www.broadcast.harris.com/leitch) to access this information.In this chapter, you can find information on the following topics:• “Packing List” on page 12• “Setting Jumpers” on page 13• “Installing the ACO-3901 Modules” on page 19• “Connecting the Input Sources” on page 22• “Connecting the External Power Supply” on page 23• “Removing ACO-3901 Modules” on page 23• “Upgrading ACO-3901 Firmware” on page 24

CautionBefore installation, please read the NEO Safety Instructions and Precautions Manual. This document contains important information about the safe installation and operation of NEO products.

ACO-3901 Installation and Operation Manual 11

Page 30: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

Packing ListThe NEO ACO-3901 module package includes these items:• One ACO-3901-FM front module• One ACO-3901-RM rear module• One ACO-3901-BM back module• One ACO-3901 Automatic Changeover Unit Installation and

Operation Manual per order

12 ACO-3901 Installation and Operation Manual

Page 31: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

Setting JumpersThe three modules that make up the ACO-3901 Automatic Changeover Unit (ACO-3901-FM, ACO-3901-RM, and ACO-3901-BM) each have jumpers that you need to set before you operate the unit for the first time.

Input and Output Impedance on the ACO-3901-FMOn the ACO-3901-FM front module, there are several jumpers to set. They can be divided into two groups:• J3 and J4: These jumpers control the TC input impedance. The

available options are High and 600Ω.

• J7, J8, J11, J13, J14, and J15: These jumpers control the TC output impedance. The available options are High and 600Ω.

Figure 2-1. Locations of J3, J4, J7, J8, J11, J13, J14, and J15 Jumpers on the ACO-3901-FM Front Module

NoteAll jumpers must be properly installed at all times in order to ensure proper functionality.

J7 and J8J3 and J4J11, J13, J14 and J15

ACO-3901 Installation and Operation Manual 13

Page 32: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

TC Input ImpedanceFollow this procedure to set the TC input impedance on the ACO-3901-FM module:1. Locate the J3 and J4 jumpers on the module.2. Place jumpers on pins 1 and 2 for 600Ω input impedance, or pins 2

and 3 (default setting) for High input impedance. See Figure 2-2.

Figure 2-2. Jumper Settings for 600Ω and High Impedance

TC Output ImpedanceFollow this procedure to set the TC output impedance on the ACO-3901-FM module:1. Locate the J7, J8, J11, J13, J14, and J15 jumpers on the module.2. Place the jumpers on pins 1 and 2 for 600Ω output impedance, or

pins 2 and 3 (default setting) for Low output impedance. See Figure 2-3.

Figure 2-3. Jumper Settings for 600Ω and Low Impedance

3 2 1 3 2 1

600Ω setting High setting(default)

3 2 1 3 2 1

600Ω setting Low setting(default)

14 ACO-3901 Installation and Operation Manual

Page 33: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

Default Input on the ACO-3901-RMThe ACO-3901-RM rear module has a default input setting that will become active in the event of a source failure. All 18 jumpers located throughout the module must be set to either MTG/CSD 1 or ExtSrc as the default input. To prevent inadvertently disabling the functionality of the ACO-3901, the GlbMTG1Ext parameter must also be set to the same option. For example, if the jumpers are changed from MTG/CSD 1 to ExtSrc, the GlbMTG1Ext parameter must also be changed to ExtSrc. Similarly, if the GlbMTG1Ext parameter is changed from the default MTG/CSD 1 to ExtSrc, all 18 jumpers must be set accordingly.

Figure 2-4. ACO-3901-RM Rear Module

Follow this procedure to set the default input:1. Locate the 18 jumpers on the ACO-3901-RM module.

ACO-3901 Installation and Operation Manual 15

Page 34: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

2. Place the jumper on pins 1 and 2 for External input (default setting), or pins 2 and 3 for MTG/CSD 1 input. See Figure 2-5.

Figure 2-5. Jumper Settings for External Input and MTG/CSD 1 Input

3 2 1 3 2 1

External setting (default)

MTG/CSD 1 setting

16 ACO-3901 Installation and Operation Manual

Page 35: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

Telco Line on the ACO-3901-BMThe ACO-3901-BM back module is capable of accepting one or two MTG-3901 (or CSD-3902) separate external inputs via the telco connector. Set the J1 and J2 jumpers to either Line 1 or Line 2. See Figure 2-6 for the location of the jumpers.• Line 1: The inner conductors are used and the two MTGs or CSDs

share the same telco line.• Line 2: The inner connectors are wired for the top MTG-3901 or

CSD-3902 module (MTG1), and the outer connectors are wired for the bottom MTG-3901 or CSD-3902 module (MTG2); each MTG or CSD module therefore has its own line.

Figure 2-6. Locations of J1 and J2 Jumpers on the ACO-3901-BM Back Module

ACO-3901 Installation and Operation Manual 17

Page 36: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

Follow this procedure to set the telco line setup for the ACO-3901-BM:1. Locate the jumpers J1 and J2 on the back (inside) of the module.2. Place the jumpers on pins 1 and 2 (default setting) to set the telco

line to Line 1, or pins 2 and 3 to set the telco line to Line 2. See Figure 2-7.

Figure 2-7. Jumper Settings for Telco Line Options

3 2 1 3 2 1

Line 1 setting(default)

Line 2 setting

18 ACO-3901 Installation and Operation Manual

Page 37: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

Installing the ACO-3901 ModulesYou can insert any NEO module into its frame with the power supply turned on or off. Follow this procedure: 1. Remove three blank back modules from the frame (two on the left

side and one on the right side).Do not discard the blank back modules and their captive screws. You may need them for future configurations.

2. Match the connection ports and then join the ACO-3901-RM rear module to the ACO-3901-BM back module. (See Figure 2-8.)

Figure 2-8. Alignment of ACO-3901-FM and ACO-3901-RM/BM Modules

3. Attach the connected ACO-3901-RM/BM module to the two empty rear slots, using the mounting screws provided.Ensure that the EMI gaskets separating the back modules remain in place during the installation. The EMI gaskets fit tightly. To ease the installation of back modules, gradually press each back module into place from the left side to the right side.

4. Apply labels to the back module, if these are supplied separately.5. Write down the placement of the back modules in the diagrams

provided in Figure 2-9.

CautionTo prevent overheating during frame operation, keep the front panel closed and all back module slots covered.

MTG-3901 #1and MTG-3901 #2orCSD-3902 #1 and CSD-3902 #2

ACO-3901-BMback module

ACO-3901-FMfront module

ACO-3901-RM rear module

ACO-3901 Installation and Operation Manual 19

Page 38: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

Figure 2-9. Writing Space for Identifying Back Modules

ALARMS

LCN

AUX

SERIAL

ETHERNET 1

ETHERNET 2

12

34

FR-3923 frame(front view)

FR-3923 frame(rear view)

FR-3901 frame(front view)

FR-3901 frame(rear view)

FR-3903 frame(rear view)

FR-3903 frame(front view)FR-3903 frame(front view)

20 ACO-3901 Installation and Operation Manual

Page 39: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

6. Open the front panel and allow it to hang freely from its hinges.7. Slide the ACO-3901-FM into the slots that match the

ACO-3901-RM/BM module. Ensure that the front modules slide inside the module guides. (See Figure 2-10.)

Figure 2-10. Front Modules in Module Guides, Front View

8. Push the front module until it seats properly.Make sure the edge of the module is flush with the edge of the module guides.

9. Close the extractor handle. (See Figure 2-11.)

Figure 2-11. Extractor Handle in Closed and Open Positions

10. Install the two MTG-3901 or two CSD-3902 modules in the remaining two slots that face the ACO-3901-BM back module, and then make all of the necessary rear connections.The module is now ready for testing.

11. Close the front panel to ensure proper frame ventilation.

Fan module NEO front module

Module guides

Closed extractor handle Open extractor handle

NoteThe primary and backup sources must both be either MTG-3901s or CSD-3902s. Two different module types cannot be mixed.

ACO-3901 Installation and Operation Manual 21

Page 40: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

Connecting the Input SourcesThe ACO-3901 is designed to accept inputs from one or two MTG-3901-FM front modules, or one or two CSD-3902-FM front modules—both of them adjacent to the ACO-3901 module. Also, it can accept another external source such as a CSD-3902 or MTG-3901 located elsewhere.

MTG-3901 ModulesThe ACO-3901-BM back module accepts either one or two MTG-3901-FM front modules, or one or two CSD-3902-FM front modules. To connect an MTG-3901-FM or CSD-3902-FM module to an ACO-3901-BM back module, follow this procedure:1. Open the front panel and allow it to hang freely from its hinges.2. Slide an MTG-3901 or CSD-3902 module into either one of the two

left slots beside the ACO-3901 module.Ensure that the module slides inside the module guides.

3. Push the module until it is seated properly.Make sure that the edge of the module is flush with the edge of the module guides.

4. Close the extractor handle.5. Install the second MTG-3901 or CSD-3902 following steps 1 to 4

above, and then make all the necessary rear connections.The module is now ready for testing.

6. Close the front panel to ensure proper frame ventilation.

External Input SourceYou can connect external sources (such as a CSD-3902 or an MTG-3901 located elsewhere) to the ACO-3901. The back module of the ACO-3901 accepts the following external sources:• Four unbalanced composite video sources, plus DARS and Hz• Balanced DB15 connector for timecode, GPI, and impulse drive

NoteThe CSD-3901 module is not compatible with the CSD-3902 module and cannot be used in an ACO-3901 configuration.

CautionDisconnect the telephone line cord when installing, removing or servicing the Master Time Generator module.

22 ACO-3901 Installation and Operation Manual

Page 41: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

Connecting the External Power SupplyThe external power supply that connects to the ACO-3901-BMis a Class 2/LPS UL/CSA certified power supply, rated at 24 VDC 3A.

Figure 2-12. Location of the External Power Supply Connector on the ACO-3901-BM Module

Removing ACO-3901 ModulesAlthough the ACO-3901 package includes a wide back module and an additional rear module, the ACO-3901 requires no specialized removal procedures. For general information about removing NEO modules, see the NEO FR-3901, FR-3903, and FR-3923 Mounting Frames Installation and Operation Manual.

External power supply connector

ACO-3901 Installation and Operation Manual 23

Page 42: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

Upgrading ACO-3901 FirmwareFirmware upgrading is a routine procedure that you must perform to install newer versions of software on NEO modules. CCS Pilot, Co-Pilot, or Navigator software applications are required for this procedure. When performing the upgrading procedure, check the appropriate readme file to confirm which files are needed. Use care to ensure that you upload the correct files to the intended module.If for some reason the upgrade fails, the module may not respond to controls and will appear to be non-functional. In that event, follow the procedures described in “Correcting a Failed Upgrading Procedure” on page 28.

Upgrading ProcedureFollow these steps to upgrade the firmware:1. Download the most recent appropriate upgrade package from the

our Web site.2. If the affected module has not been discovered, perform the

Discovery operation, as described in your CCS software application manual or online help. (If you cannot discover the device, see “Discovering Devices Using the Drag-and-Drop Method” on page 26.)

24 ACO-3901 Installation and Operation Manual

Page 43: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

3. From the Tools menu, select Software Upgrade. The Software Upgrade window opens or is brought to the foreground.

Figure 2-13. Software Upgrade Tool’s New Transfer Tab

4. On the New Transfer tab, click Add.The Device Selection dialog opens.

5. Select one or more devices, and then click OK to close the Add Device dialog box.You can only add one unit from each IP address. All items in a frame have the same IP address. The selected devices appear in the table on the New Transfer tab of the Software Upgrade window. This table lists devices that are to receive the same upgrade package.

Click here to access options for entering Telnet and FTP user name and password and creating automatic backups.

Package Info includes a list of the components contained in the ZIP file.

ACO-3901 Installation and Operation Manual 25

Page 44: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

For each device in this table, you can highlight its position in the Tree View by clicking Find Device. You can check the software revision numbers, etc., by clicking Version Info, and create an automatic backup by clicking the Device Options... button. (Place a check beside Software Backup and enter a file name or click Browse to choose a new file location.)

6. Press Browse... to select the software upgrade package (ZIP file). A standard Windows File Selection dialog opens.

7. Choose the upgrade ZIP file on a local or network drive. The selected file’s path name is displayed in the edit box to the left of the Browse… button.The extraction process on the ZIP file is handled as part of the upgrade process. You do not need to extract the files yourself.

8. Press Submit Transfer... A dialog box opens, requesting confirmation that you want to proceed with the request. If you have multiple devices selected, multiple transfer tasks are submitted—one per device.The transfer now progresses. You may close the Software Upgrade window, or continue with other tasks. Closing the window does not effect any of the transfer processes that may be running in the background.Or you can switch to the Progress tab to view the status of the transfers.

9. Click on the Log tab and look at the Progress column to ensure that all files have correctly updated. The module is automatically rebooted following an upgrade procedure.

Discovering Devices Using the Drag-and-Drop MethodIf you are unable to discover the device (as described in step 2 on page 24), follow these steps to upgrade the firmware using the drag-and-drop method:1. Download the appropriate most recent upgrade package from the

our Web site or from your CD-ROM, and then unzip the upgrade package.

NoteClosing the Software Upgrade window does not effect any of the transfer processes that may be running in the background.

NoteIf you try to log off or exit the CCS software while a transfer is underway, a notification window will alert you that processes are still active and will ask if you want to terminate these processes.

26 ACO-3901 Installation and Operation Manual

Page 45: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

2. If the affected module has not been discovered by your CCS software application, enter the Build mode, and then drag or copy and paste the module’s device icon from the catalog folder into the Network or Discovery folder.

3. Right-click the device icon and then select Properties. 4. On the NRO or Device tab of the Navigation Properties box, enter

the IP address of the frame that holds the module. (See Figure 2-14.)

Figure 2-14. Navigation Properties Box

5. In the third field, enter the slot number of the module as shown in Figure 2-15, and then close the window.

To enter information into the frame and slot field (the third field in CCS-3.0), follow the convention shown in Figure 2-15 on page 28. The first number in the third field should always be 1. The second number should always be 0. The third number is the slot number in the NEO frame (for example, 10). Resource modules will now appear as 17 or 18 in this third number spot, instead of 101 and 102, as in earlier versions. In the unlikely event that you cannot discover the frame, the number 0 may be used to represent the frame.

NoteThe Device ID line will be slightly different than in previous versions. The acronym EP will appear—instead of IP—in the first Device ID field. The frame and slot number now are entered in the third field instead of the last field. And the area in which you should not enter any data is now the last field (previously the third field).

Do not make changes in this field

Enter frame IP number here

ACO-3901 Installation and Operation Manual 27

Page 46: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

Figure 2-15. Inserting Numbers in the Frame and Slot Field

6. Continue upgrading your device’s firmware, starting with Step 3 on page 25.

Correcting a Failed Upgrading ProcedureFirmware upgrades may fail in the event of network interruptions, power failures, or if too much data is uploaded to the NEO module. Often, uploads of too much data can occur for one of the following reasons:• The boot file (typically vxWorks.lzs) was accidentally uploaded

during the fl0 procedure, instead of the boot procedure.• Files were sent to the wrong NEO module.• The particular hardware version of the module requires only some

(but not all) of the available fl0 files.• The upgrade .zip file was mistakenly sent to the module.All of these problems can be corrected by re-installing the firmware while in a fail-safe mode, as described in the following pages. When you are performing this procedure, check the appropriate readme file to confirm which files are needed. Use care to ensure that you upload the correct files to the intended module.Three general steps are involved in correcting a failed upgrading procedure. These steps are found in the following sections: 1. “Setting the Module to Fail-Safe Loader Mode” (see below)2. “Upgrading the Firmware in the Boot Folder in Fail-Safe Mode” on

page 29

Always set to 1Always set to 0 for NEO products

Insert slot number: -1 to 12 for regular modules-17 or 18 for resource modu-0 for a NEO frame

28 ACO-3901 Installation and Operation Manual

Page 47: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

3. “Upgrading the Firmware in the Fl0 Folder and Rebooting the Module” on page 31

Setting the Module to Fail-Safe Loader ModeFollow these steps to set a NEO module to the fail-safe loader mode:1. Remove the affected module from the NEO frame.2. Press the Nav switch down while simultaneously pressing both the

Escape and Enter buttons.

Figure 2-16. Buttons on a Typical Card Edge

3. While still pressing the buttons and the navigation switch, reinsert the module into the frame and hold for approximately three seconds until the display on the module reads Offline-H (or Offline-L) Upload Required.

Upgrading the Firmware in the Boot Folder in Fail-Safe ModeEnsure that you follow these steps in the exact sequence when upgrading the firmware in fail-safe mode: 1. Download the most recent appropriate upgrade package from the

our Web site or from your CD-ROM, and then unzip the upgrade package.

2. If the affected module has not been discovered by your CCS software application, enter Build mode, and then drag or copy and paste the module’s device icon from the catalog folder into the Network or Discovery folder.

3. Right-click the device icon and then select Properties. On the Device tab of the Navigation Properties box, enter the IP address of the frame that holds the module. (See Figure 2-17.)

Escape button

Navigation button

Enter button

NoteTo successfully upgrade the firmware, you must follow these steps in the exact sequence described.

ACO-3901 Installation and Operation Manual 29

Page 48: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

4. On the Device tab of the Navigation Properties box, enter the IP address of the frame that holds the module. (See Figure 2-17.)

Figure 2-17. Navigation Properties Box

5. In the third field, enter: 1.0.[slotnumber](Where, for example, 1.0.5 would refer to the module in slot 5 of the frame.)

6. Close the window.7. Double-click the device icon.

The Configuration... box opens. On the File Transfer tab, the /slotx/boot (where x is the slot number) directory appears in the Select the device directory to transfer to: field.

8. Click Add, and in the Add Upgrade Files box, browse, select the boot folder in the module’s upgrade package and then click OK.

9. Choose the vxWorks.lzs file and then click OK.10. Click Perform Transfer and then click Yes.

This may take several minutes.11. Wait for the message File transfer to device succeeded in the

status bar.See “Upgrading the Firmware in the Fl0 Folder and Rebooting the Module” below to continue the correction procedure.

NoteThe Device ID line will be slightly different than in previous versions. The acronym EP will appear—instead of IP—in the first Device ID field. The frame and slot number now are entered in the third field instead of the last field. And the area in which you should not enter any data is now the last field (previously the third field).

Do not make changes in this field

Enter frame IP address here

30 ACO-3901 Installation and Operation Manual

Page 49: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

Upgrading the Firmware in the Fl0 Folder and Rebooting the ModuleThis procedure is meant to be performed directly after “Upgrading the Firmware in the Boot Folder in Fail-Safe Mode” on page 29.Follow these steps to reboot the affected NEO module:1. Click Reboot Device, and then click Yes.

After the module has rebooted, a message box advises you to wait until the device has rebooted.

2. Wait 30 seconds.3. On the File Transfer tab, select the /slotx/fl0 (where x is the slot

number) directory in the Select the device directory to transfer to: field.

4. Click Add, browse and select the fl0 folder in the module’s upgrade package, and then click OK. Check the readme for the upgrade package to ensure that you are adding the correct files.

5. Select the files shown in the Add Upgrade Files box, and then click OK.

6. Select and delete unwanted files (for example: vxWorks.lzs) in the Add upgrade files for transfer to device: field by clicking Remove.

7. Click Perform Transfer and then click Yes.8. Wait for the message File transfer to device succeeded.

This may take a moment.9. Click Reboot Device and then click Yes.10. Wait 30 seconds, and then close the Configuration... box.

The module name appears at the card edge.The upgrade procedure is complete.

NoteSome NEO modules will reboot automatically. In these cases, the Reboot button will be grayed out. During this time, the module’s card-edge display will show the word Rebooting before the name of the module appears. These modules do not require the fl0 file.

CautionYou must delete unwanted files in the Add upgrade files for transfer to device: field before transferring the files. Otherwise, the upgrading procedure will fail.

ACO-3901 Installation and Operation Manual 31

Page 50: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 2: Installation and Removal

32 ACO-3901 Installation and Operation Manual

Page 51: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3

Operation

OverviewInstallation, navigation, configuration, and setup information is now included in the NEO FR-3901, FR-3903, and FR-3923 Mounting Frames Installation and Operation Manual. If your current NEO frame manual is Edition A, B, C, or D, you will need to download an updated version from our Web site (www.broadcast.harris.com/leitch) to access this information.This chapter describes how to operate the ACO-3901 module using card-edge controls. The following topics are found in this chapter:• “Operation Notes” on page 34• “GPO Pinouts” on page 34• “Cross-Functional Parameter Changes” on page 36• “Navigating the Operator and All Lists” on page 39• “Operator and All List Parameters” on page 40• “Setup Parameters” on page 56• “Alarms” on page 57• “State Recovery Parameter Availability” on page 62• “LED and Module Indicators” on page 63

ACO-3901 Installation and Operation Manual 33

Page 52: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

Operation NotesWhen using the ACO-3901 module, the following operation notes should be observed:• Although the effect of a parameter change may appear to be

immediate, the module requires 20 seconds to save the latest change. If another change is made during these 20 seconds, the first parameter change and the second parameter change will not be saved until 20 seconds after the second parameter change. There is no limit to the number of changes that can be made within 20 seconds of each other. However, none of these changes will be saved until 20 seconds after the last parameter change.

• When the FctryRcl (factory recall) parameter is set to Yes, the module takes several seconds to reset all of the parameters. (See the “Operator and All List Parameters” on page 40 or the “Tree View Parameters” on page 75 to view the factory recall default settings.) Setup parameters are not affected by the factory recall mode.

• Some parameters will be locked out if certain settings are made. When this occurs, a lock icon will appear beside the affected parameters in the card-edge VFD.

GPO PinoutsTable 1-3 on page 7 lists back module pins of the DB-15 connector that include the GPI output closures labelled GPO_CL1 and GPO_CL2. These two pins are controlled by a number of parameters that begin on page 50 in the Operator and All List, and page 80 of the Tree View.To configure the two GPOs, enable or disable those parameters (shown in the following excerpt from pages 50 to 51 of the Operator and All List). Although the names of the parameters begin with “GPI,” they are in fact, used to configure the GPOs.

CautionFailure to observe these “Operation Notes” will result in accidental changes to the module’s parameter settings.

34 ACO-3901 Installation and Operation Manual

Page 53: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

The GPO_CL1 and GPO_CL2 connections are normally open with respect to each other and there is a relay connected between them. When any of the enabled GPI triggers are activated, the relay is closed, and this closes the connection between the GPO pins. The relay has a capacity of 0.5 amps.You can use any or all of these parameters to program the activation of alarms for the ACO-3901.

Table 3-1. Parameters Used to Configure GPO1 and GPO2

Card-Edge ID Parameter Name Function

GPIPPSEn GPI Primary Power Supply Enable Enables the GPI on a primary power supply fault

GPISPSEn GPI Secondary Power Supply Enable Enables the GPI on an external power supply fault

GPIMTG1En GPI MTG1 Enable Enables the GPI on an MTG1 fault

GPIMTG2En GPI MTG2 Enable Enables the GPI on an MTG2 fault

GPIExtEn GPI Ext Enable Enables the GPI on an external source fault

GPIOutEn GPI Output Enable Enables the GPI on an output fault

GPICPUEn GPI CPU Enable Enables the GPI on a CPU dead fault

GPIM1ActEn GPI MTG1 Active Action Enable Enables the GPI on an MTG1 active action

GPIM2ActEn GPI MTG2 Active Action Enable Enables the GPI on an MTG2 active action

GPIExActEn GPI External Active Action Enable Enables the GPI on an external source active action

GPIM1VBEn GPI MTG1 Validation Block Enable Enables the GPI on an MTG1 validation block fault

GPIM2VBEn GPI MTG2 Validation Block Enable Enables the GPI on an MTG2 validation block fault

GPIExtVBEn GPI External Validation Block Enable Enables the GPI on an external validation block fault

ACO-3901 Installation and Operation Manual 35

Page 54: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

Cross-Functional Parameter ChangesChanges that are made to parameter settings sometimes cause unexpected changes in other parameter settings. The following table lists the forced settings and disabled parameters that result when certain parameter settings are changed.

Table 3-2. Cross-Functional Parameter Changes

Condition Forced Setting Changed ParametersGlbSetSrc GlbSetSrc = Ext_Src, MTG/CSD 1 or

MTG/CSD 2 when using MTG-3901ImpSetSrc, HZSetSrc, LTC1SetSrc, LTC2SetSrc, DARSSetSrc, Cmp1SetSrc, Cmp2SetSrc, Cmp3SetSrc, Cmp4SetSrc are disabled

GlbSetSrc GlbSetSrc = Ext_Src, MTG/CSD 1 or MTG/CSD 2 when using CSD-3902

ImpSetSrc, HZSetSrc, LTC1SetSrc, LTC2SetSrc, DARSSetSrc, Cmp1SetSrc are disabled

GlbSetSrc GlbSetSrc = IndvCtrl when using MTG-3901

ImpSetSrc, HZSetSrc, LTC1SetSrc, LTC2SetSrc, DARSSetSrc, Cmp1SetSrc, Cmp2SetSrc, Cmp3SetSrc, Cmp4SetSrc are enabled

GlbSetSrc GlbSetSrc = IndvCtrl when using CSD-3902

ImpSetSrc, HZSetSrc, LTC1SetSrc, LTC2SetSrc, DARSSetSrc, Cmp1SetSrc are enabled

ImpValEn ImpValEn = Disable M1ImpErr, M2ImpErr, ExtImpErr, OutImpErr are disabled

ImpValEn ImpValEn = Enable M1ImpErr, M2ImpErr, ExtImpErr, OutImpErr are enabled

HzValEn HzValEn = Disable M1HzErr, M2HzErr, ExtHzErr, OutHzErr are disabled

HzValEn HzValEn = Enable M1HzErr, M2HzErr, ExtHzErr, OutHzErr are enabled

LTC1ValEn LTC1ValEn = Disable M1LTC1Err, M2LTC1Err, ExtLTC1Err, OutLTC1Err are disabled

LTC1ValEn LTC1ValEn = Enable M1LTC1Err, M2LTC1Err, ExtLTC1Err, OutLTC1Err are enabled

LTC2ValEn LTC2ValEn = Disable M1LTC2Err, M2LTC2Err, ExtLTC2Err, OutLTC2Err are disabled

36 ACO-3901 Installation and Operation Manual

Page 55: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

LTC2ValEn LTC2ValEn = Enable M1LTC2Err, M2LTC2Err, ExtLTC2Err, OutLTC2Err are enabled

DARSValEn DARSValEn = Disable M1DARSErr, M2DARSErr, ExtDARSErr, OutDARSErr are disabled

DARSValEn DARSValEn = Enable M1DARSErr, M2DARSErr, ExtDARSErr, OutDARSErr are enabled

Cmp1ValEn Cmp1ValEn = Disable M1Cmp1Err, M2Cmp1Err, ExtCmp1Err, OutCmp1Err are disabled

Cmp1ValEn Cmp1ValEn = Enable M1Cmp1Err, M2Cmp1Err, ExtCmp1Err, OutCmp1Err are enabled

Cmp2ValEn Cmp2ValEn = Disable M1Cmp2Err, M2Cmp2Err, ExtCmp2Err, OutCmp2Err are disabled

Cmp2ValEn Cmp2ValEn = Enable M1Cmp2Err, M2Cmp2Err, ExtCmp2Err, OutCmp2Err are enabled

Cmp3ValEn Cmp3ValEn = Disable M1Cmp3Err, M2Cmp3Err, ExtCmp3Err, OutCmp3Err are disabled

Cmp3ValEn Cmp3ValEn = Enable M1Cmp3Err, M2Cmp3Err, ExtCmp3Err, OutCmp3Err are enabled

Cmp4ValEn Cmp4ValEn = Disable M1Cmp4Err, M2Cmp4Err, ExtCmp4Err, OutCmp4Err are disabled

Table 3-2. Cross-Functional Parameter Changes (Continued)

Condition Forced Setting Changed Parameters

ACO-3901 Installation and Operation Manual 37

Page 56: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

Cmp4ValEn Cmp4ValEn = Enable M1Cmp4Err, M2Cmp4Err, ExtCmp4Err, OutCmp4Err are enabled

If two CSD-3902s are connected to the ACO-3901 • Cmp2ValEn, Cmp3ValEn, and Cmp4ValEn are set to Disable

• Cmp2SetSrc, Cmp2SetFM, Cmp2SrcStd, Cmp2Src, Cmp3SetSrc, Cmp3SetFM, Cmp3SrcStd, Cmp3Src, Cmp4SetSrc, Cmp4SetFM, Cmp4SrcStd, Cmp4Src, M1C2DetStd, M1C3DetStd, M1C4DetStd, M2C2DetStd, M2C3DetStd, M2C4DetStd, ExC2DetStd, ExC3DetStd, ExC4DetStd, Val4C2DetStd, Val4C3DetStd, Val4C4DetStd, Cmp2ValEn, Cmp3ValEn, Cmp4ValEn, M1VCmp2Err, M1VCmp3Err, M1VCmp4Err, M2VCmp2Err, M2VCmp3Err, M2VCmp4Err, ExVCmp2Err, ExVCmp3Err, ExVCmp4Err are disabled

If two MTG-3901 are connected to the ACO-3901 • Cmp2ValEn, Cmp3ValEn, and Cmp4ValEn are set to Enable

• Cmp2SetSrc, Cmp2SetFM, Cmp2SrcStd, Cmp2Src, Cmp3SetSrc, Cmp3SetFM, Cmp3SrcStd, Cmp3Src, Cmp4SetSrc, Cmp4SetFM, Cmp4SrcStd, Cmp4Src, M1C2DetStd, M1C3DetStd, M1C4DetStd, M2C2DetStd, M2C3DetStd, M2C4DetStd, ExC2DetStd, ExC3DetStd, ExC4DetStd, Val4C2DetStd, Val4C3DetStd, Val4C4DetStd, Cmp2ValEn, Cmp3ValEn, Cmp4ValEn, M1VCmp2Err, M1VCmp3Err, M1VCmp4Err, M2VCmp2Err, M2VCmp3Err, M2VCmp4Err, ExVCmp2Err, ExVCmp3Err, ExVCmp4Err are enabled

Table 3-2. Cross-Functional Parameter Changes (Continued)

Condition Forced Setting Changed Parameters

38 ACO-3901 Installation and Operation Manual

Page 57: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

Navigating the Operator and All ListsTo navigate, and then view or change a parameter from the Operator and All Lists, follow these steps:1. Open the front panel of the NEO frame.2. Press any card-edge control to turn on the VFD screen.

The message ACO-3901 appears. If a previous user has left the display at a different parameter name, repeatedly press the Escape button until the message ACO-3901 appears.

3. Push the Enter button.The name of the first parameter option in the list appears.

4. Push the Enter button again to access the options for the parameter displayed on the VFD screen.ORPress the Nav+/Nav- switch down repeatedly to view other parameters, and then press Enter to access an item’s parameter options.

5. Press the Nav+/Nav- switch up or down to scroll through the different selectable parameter options, and then press Enter to select the value you want.ORPress the Nav+/Nav- switch up or down to adjust the numeric parameter value, and then press Enter.

6. Close the front panel of the frame to ensure the cooling system continues to operate properly.

NoteAfter several seconds of inactivity, a scrolling message will appear, describing the purpose of the currently selected parameter.

ACO-3901 Installation and Operation Manual 39

Page 58: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

Operator and All List ParametersThis complete list of parameter settings is arranged so that the settings most likely requiring changes are placed at the top of the list. Items on the bottom of the list are the least likely to require changing. Parameters with the designation [RO] are “read-only.” An asterisk (*) indicates the default user range or value.The All List is a long flat list of all the available parameters, arranged from the most-used to least-used. It is intended for a “Supervisor” security designation. The Operator List is a condensed version of the All List, and is intended for an “Operator” security designation. The following table shows all available parameters. Parameters accessed only from within the All List are shaded in gray.See “Navigating the Operator and All Lists” on page 39 for instructions on navigating this list using card-edge controls.

NoteYou can reset the default values for all of the parameters automatically via the FctryRcl parameter, found in this table.

Table 3-3. ACO-3901 Operator and All List Parameters

Card-Edge ID Parameter Name Function User Range

or OptionsGlbSetEnbl Global Set Enable Enables ACO-3901 functionality • Disable

• Enable*

GlbSetCtrl Global Set Control Determines how to switch in the event of a failure

• Auto*• Auto-Once• Manual Reset

GlbSetSrc Global Set Source Selects which input source is routed to the output

• MTG/CSD 1*• MTG/CSD 2• Ext_Src• IndvCtrl

GlbSrc [RO] Global Source Reads which input source is routed to output • Ext_Src• MTG/CSD 1• MTG/CSD 2

GlbSetMode Global Set Mode Sets the operational mode of the ACO-3901 • Auto*• MTG• CSD

40 ACO-3901 Installation and Operation Manual

Page 59: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

GlbMTG1Ext Global MTG1-External

Selects either MTG/CSD1 or external source • MTG/CSD 1*• ExtSrc

GLBBSetSrc Genlock Set Source Selects the source of the genlock black burst signal

• Auto*• MTG/CSD 1• MTG/CSD 2• Ext_Src

Val4SetSrc 4th Validation Block Set Source

Selects the input source to the 4th validation block

• Auto*• MTG/CSD 1• MTG/CSD 2• Ext_Src• Outputs

ImpSetSrc Impulse Set Source Selects the source to output for the impulse block

• MTG/CSD 1*• MTG/CSD 2• Ext_Src

ImpSetFM Impulse Set Fail Mode Determines the criteria the impulse block will fail on

• SignalLev*• Freq

ImpSrc [RO] Impulse Source Indicates the impulse source being routed to the output

• Ext_Src• MTG/CSD 1• MTG/CSD 2

HZSetSrc Frequency Set Source Selects the source to output for the frequency output block

• MTG/CSD 1*• MTG/CSD 2• Ext_Src

HZSetFM Frequency Set Fail Mode

Determines the criteria the frequency output block will fail on

• SignalLev*• Freq

HZSrc [RO] Frequency Source Indicates the source being routed to output for the frequency output block

• Ext_Src• MTG/CSD 1• MTG/CSD 2

LTC1SetSrc LTC 1 Set Source Selects the source to output for the LTC 1 block

• MTG/CSD 1*• MTG/CSD 2• Ext_Src

Table 3-3. ACO-3901 Operator and All List Parameters (Continued)

Card-Edge ID Parameter Name Function User Range

or Options

ACO-3901 Installation and Operation Manual 41

Page 60: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

LTC1SetFM LTC 1 Set Fail Mode Determines the criteria the LTC 1 block willfail on

• SignalLev*• Format

LTC1Src [RO] LTC 1 Source Indicates the source being routed to output for the LTC 1 block

• Ext_Src• MTG/CSD 1• MTG/CSD 2

LTC2SetSrc LTC 2 Set Source Selects which source to output for the LTC 2 block

• MTG/CSD 1*• MTG/CSD 2• Ext_Src

LTC2SetFM LTC 2 Set Fail Mode Determines the criteria the LTC 2 block will fail on

• SignalLev*• Format

LTC2Src [RO] LTC 2 Source Indicates the source being routed to output for the LTC 2 block

• Ext_Src• MTG/CSD 1• MTG/CSD 2

DARSSetSrc DARS Set Source Selects the source to output for the DARS block

• MTG/CSD 1*• MTG/CSD 2• Ext_Src

DARSSetFM DARS Set Fail Mode Determines the criteria the DARS block will fail on

• SignalLev*• Audio

DARSSrc [RO]

DARS Source Indicates the source being routed to the output for DARS block

• Ext_Src• MTG/CSD 1• MTG/CSD 2

Cmp1SetSrc Composite 1 Set Source

Selects the source to output for the composite video 1 block

• MTG/CSD 1*• MTG/CSD 2• Ext_Src

Cmp1SetFM Composite 1 Set Fail Mode

Determines the criteria the composite video 1 block will fail on

• SignalLev*• Standard

Table 3-3. ACO-3901 Operator and All List Parameters (Continued)

Card-Edge ID Parameter Name Function User Range

or Options

42 ACO-3901 Installation and Operation Manual

Page 61: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

Cmp1SrcStd Composite 1 Source Standard

Selects the source standard for the composite video 1 block

• LR_625• LR_525• LR1080p_23• LR1080p_24• LR1080p_25• LR1080p_29• LR1080p_30• LR1080i_50• LR1080i_59• LR1080i_60• LR1080f_23• LR1080f_24

• Auto*• LR720p_50• LR720p_59• LR720p_60

Cmp1Src [RO]

Composite 1 Source Indicates the source being routed to output for the composite video 1 block

• Ext_Src• MTG/CSD 1• MTG/CSD 2

Cmp2SetSrc Composite 2 Set Source

Selects the source to output for the composite video 2 block

• MTG_1*• MTG_2• Ext_Src

Cmp2SetFM Composite 2 Set Fail Mode

Determines the criteria the composite video 2 block will fail on

• SignalLev*• Standard

Table 3-3. ACO-3901 Operator and All List Parameters (Continued)

Card-Edge ID Parameter Name Function User Range

or Options

ACO-3901 Installation and Operation Manual 43

Page 62: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

Cmp2SrcStd Composite 2 Source Standard

Selects the source standard for the composite video 2 block

• LR_625• LR_525• LR1080p_23• LR1080p_24• LR1080p_25• LR1080p_29• LR1080p_30• LR1080i_50• LR1080i_59• LR1080i_60• LR1080f_23• LR1080f_24

• Auto*• LR720p_50• LR720p_59• LR720p_60

Cmp2Src [RO]

Composite 2 Source Indicates the source being routed to output for the composite video 2 block

• Ext_Src• MTG_1• MTG_2

Cmp3SetSrc Composite 3 Set Source

Selects the source to output for the composite video 3 block

• MTG_1*• MTG_2• Ext_Src

Cmp3SetFM Composite 3 Set Fail Mode

Determines the criteria the composite video 3 block will fail on

• SignalLev*• Standard

Table 3-3. ACO-3901 Operator and All List Parameters (Continued)

Card-Edge ID Parameter Name Function User Range

or Options

44 ACO-3901 Installation and Operation Manual

Page 63: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

Cmp3SrcStd Composite 3 Source Standard

Selects the source standard for the composite video 3 block

• LR_625• LR_525• LR1080p_23• LR1080p_24• LR1080p_25• LR1080p_29• LR1080p_30• LR1080i_50• LR1080i_59• LR1080i_60• LR1080f_23• LR1080f_24

• Auto*• LR720p_50• LR720p_59• LR720p_60

Cmp3Src [RO]

Composite 3 Source Indicates the source being routed to output for the composite video 3 block

• Ext_Src• MTG_1• MTG_2

Cmp4SetSrc Composite 4 Set Source

Selects the source to output for the composite video 4 block

• MTG_1*• MTG_2• Ext_Src

Cmp4SetFM Composite 4 Set Fail Mode

Determines the criteria the composite video 4 block will fail on

• SignalLev*• Standard

Table 3-3. ACO-3901 Operator and All List Parameters (Continued)

Card-Edge ID Parameter Name Function User Range

or Options

ACO-3901 Installation and Operation Manual 45

Page 64: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

Cmp4SrcStd Composite 4 Source Standard

Selects the source standard for the composite video 4 block

• LR_625• LR_525• LR1080p_23• LR1080p_24• LR1080p_25• LR1080p_29• LR1080p_30• LR1080i_50• LR1080i_59• LR1080i_60• LR1080f_23• LR1080f_24

• Auto*• LR720p_50• LR720p_59• LR720p_60

Cmp4Src [RO]

Composite 4 Source Indicates the source being routed to output for the composite video 4 block

• Ext_Src• MTG_1• MTG_2

Table 3-3. ACO-3901 Operator and All List Parameters (Continued)

Card-Edge ID Parameter Name Function User Range

or Options

46 ACO-3901 Installation and Operation Manual

Page 65: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

M1C1DetStd to M1C4DetStd [RO]

MTG1 Composite 1 Detected Standard to MTG1 Composite 4 Detected Standard

Detects the Composite 1 to Composite 4 input standards on MTG1

• LR_625• LR_525• LR1080p_23• LR1080p_24• LR1080p_25• LR1080p_29• LR1080p_30• LR1080i_50• LR1080i_59• LR1080i_60• LR1080f_23• LR1080f_24• None• LR720p_50• LR720p_59• LR720p_60

M2C1DetStdtoM2C4DetStd [RO]

MTG2 Composite 1 Detected StandardtoMTG2 Composite 4 Detected Standard

Detects the Composite 1 to Composite 4 input standards on MTG2

• LR_625• LR_525• LR1080p_23• LR1080p_24• LR1080p_25• LR1080p_29• LR1080p_30• LR1080i_50• LR1080i_59• LR1080i_60• LR1080f_23• LR1080f_24• None• LR720p_50• LR720p_59• LR720p_60

Table 3-3. ACO-3901 Operator and All List Parameters (Continued)

Card-Edge ID Parameter Name Function User Range

or Options

ACO-3901 Installation and Operation Manual 47

Page 66: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

ExC1DetStd toExC4DetStd [RO]

External Composite 1 Detected StandardtoExternal Composite 4 Detected Standard

Detects the external Composite 1 to Composite 4 input standards

• LR_625• LR_525• LR1080p_23• LR1080p_24• LR1080p_25• LR1080p_29• LR1080p_30• LR1080i_50• LR1080i_59• LR1080i_60• LR1080f_23• LR1080f_24• None• LR720p_50• LR720p_59• LR720p_60

Val4C1DetStd toVal4C4DetStd [RO]

Output Composite 1 Detected StandardtoOutput Composite 4 Detected Standard

Detects the output Composite 1 to Composite 4 standards

• LR_625• LR_525• LR1080p_23• LR1080p_24• LR1080p_25• LR1080p_29• LR1080p_30• LR1080i_50• LR1080i_59• LR1080i_60• LR1080f_23• LR1080f_24• None• LR720p_50• LR720p_59• LR720p_60

Table 3-3. ACO-3901 Operator and All List Parameters (Continued)

Card-Edge ID Parameter Name Function User Range

or Options

48 ACO-3901 Installation and Operation Manual

Page 67: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

AudAlrmTst Audio Alarm Test Tests the Major and Minor audio alarms • Disable*• EnMjrTst• EnMinTst

AudPPSEn Audio Alarm Primary Power Supply Enable

Enables the audio alarm on a frame power supply fault

• Disable*• Enable

AudSPSEn Audio Alarm External Power Supply Enable

Enables the audio alarm on an external power supply fault

• Disable*• Enable

AudMTG1En Audio Alarm MTG1 Enable

Enables the audio alarm on an MTG1 fault • Disable*• Enable

AudMTG2En Audio Alarm MTG2 Enable

Enables the audio alarm on an MTG2 fault • Disable*• Enable

AudExtEn Audio Alarm External Enable

Enables the audio alarm on an external source fault

• Disable*• Enable

AudOutEn Audio Alarm Output Enable

Enables the audio alarm on an output fault • Disable*• Enable

AudCPUEn Audio Alarm CPU Enable

Enables the audio alarm on a CPU Dead fault • Disable*• Enable

AudM1VBEn Audio Alarm MTG1 Validation Block Enable

Enables the audio alarm on a MTG1 validation block fault

• Disable*• Enable

AudM2VBEn Audio Alarm MGT2 Validation Block Enable

Enables the audio alarm on a MTG2 validation block fault

• Disable*• Enable

AudExtVBEn Audio Alarm External Validation Block Enable

Enables the audio alarm on an external validation block fault

• Disable*• Enable

AlrmPPSEn Alarm Primary Power Supply Enable

Sets the alarm type for a frame power supply fault

• Minor*• Major

AlrmSPSEn Alarm Secondary Power Supply Enable

Sets the alarm type for an external power supply fault

• Minor*• Major

Table 3-3. ACO-3901 Operator and All List Parameters (Continued)

Card-Edge ID Parameter Name Function User Range

or Options

ACO-3901 Installation and Operation Manual 49

Page 68: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

AlrmMTG1En Alarm MTG1 Enable Sets the alarm type for an MTG1 fault • Minor*• Major

AlrmMTG2En Alarm MTG2 Enable Sets the alarm type for an MTG2 fault • Minor*• Major

AlrmExtEn Alarm External Enable Sets the alarm type for a external source fault • Minor*• Major

AlrmOutEn Alarm Output Enable Sets the alarm type for an output fault • Minor*• Major

AlrmCPUEn Alarm CPU Enable Sets the alarm type for a CPU dead fault • Minor*• Major

AlrmM1VBEn Alarm MTG1 Validation Block Enable

Sets the alarm type for an MTG1 validation block

• Minor*• Major

AlrmM2VBEn Alarm MTG2 Validation Block Enable

Sets the alarm type for an MTG2 validation block fault

• Minor*• Major

AlrmExVBEn Alarm External Validation Block Enable

Sets the alarm type for an external validation block fault

• Minor*• Major

GPIPPSEn GPI Primary Power Supply Enable

Enables the GPI on a primary power supply fault

• Disable

• Enable*

GPISPSEn GPI Secondary Power Supply Enable

Enables the GPI on an external power supply fault

• Disable

• Enable*

GPIMTG1En GPI MTG1 Enable Enables the GPI on an MTG1 fault • Disable

• Enable*

GPIMTG2En GPI MTG2 Enable Enables the GPI on an MTG2 fault • Disable

• Enable*

GPIExtEn GPI Ext Enable Enables the GPI on an external source fault • Disable

• Enable*

GPIOutEn GPI Output Enable Enables the GPI on an output fault • Disable

• Enable*

Table 3-3. ACO-3901 Operator and All List Parameters (Continued)

Card-Edge ID Parameter Name Function User Range

or Options

50 ACO-3901 Installation and Operation Manual

Page 69: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

GPICPUEn GPI CPU Enable Enables the GPI on a CPU dead fault • Disable

• Enable*

GPIM1ActEn GPI MTG1 Active Action Enable

Enables the GPI on an MTG1 active action • Disable

• Enable*

GPIM2ActEn GPI MTG2 Active Action Enable

Enables the GPI on an MTG2 active action • Disable

• Enable*

GPIExActEn GPI External Active Action Enable

Enables the GPI on an external source active action

• Disable

• Enable*

GPIM1VBEn GPI MTG1 Validation Block Enable

Enables the GPI on an MTG1 validation block fault

• Disable

• Enable*

GPIM2VBEn GPI MTG2 Validation Block Enable

Enables the GPI on an MTG2 validation block fault

• Disable

• Enable*

GPIExtVBEn GPI External Validation Block Enable

Enables the GPI on an external validation block fault

• Disable

• Enable*

ImpValEn Impulse Validation Block Enable

Enables impulse validation • Disable

• Enable*

HzValEn Frequency Validation Enable

Enables frequency validation • Disable

• Enable*

LTC1ValEn LTC1 Validation Enable

Enables LTC1 validation • Disable

• Enable*

LTC2ValEn LTC2 Validation Enable

Enables LTC2 validation • Disable

• Enable*

DARSValEn DARS Validation Enable

Enables DARS validation • Disable

• Enable*

Cmp1ValEn toCmp4ValEn

Composite 1 Validation Enable to Composite 4 Validation Enable

Enables Composite 1 to Composite 4 input validation

• Disable

• Enable*

MTG1Fail [RO]

MTG1 Failure Indicates whether MTG1 has a failure • Fail• NoFail

Table 3-3. ACO-3901 Operator and All List Parameters (Continued)

Card-Edge ID Parameter Name Function User Range

or Options

ACO-3901 Installation and Operation Manual 51

Page 70: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

MTG2Fail [RO]

MTG2 Failure Indicates whether MTG2 has a failure • Fail• NoFail

ExtSrcFail [RO]

External Source Failure

Indicates whether external source has failure • Fail• NoFail

MonOutFail [RO]

Monitor Output Failure Indicates whether the ACO output circuitry has failed

• Fail• NoFail

M1ImpErr [RO]

MTG1 Impulse Error Reports an MTG1 impulse error • Fail• NoFail

M1HzErr [RO]

MTG1 Frequency Error

Reports an MTG1 frequency error • Fail• NoFail

M1LTC1Err [RO]

MTG1 LTC1 Error Reports an MTG1 LTC1 error • Fail• NoFail

M1LTC2Err [RO]

MTG1 LTC2 Error Reports an MTG1 LTC2 error • Fail• NoFail

M1DARSErr [RO]

MTG1 DARS Error Reports an MTG1 DARS error • Fail• NoFail

M1Cmp1Err to M1Cmp4Err [RO]

MTG1 Composite 1 Error to MTG1 Composite 4 Error

Reports an MTG1 Composite 1 to Composite 4 input error

• Fail• NoFail

M2ImpErr [RO]

MTG2 Impulse Error Reports an MTG2 impulse error • Fail• NoFail

M2HzErr [RO]

MTG2 Frequency Error

Reports an MTG2 frequency error • Fail• NoFail

M2LTC1Err [RO]

MTG2 LTC1 Error Reports an MTG2 LTC1 error • Fail• NoFail

M2LTC2Err [RO]

MTG2 LTC2 Error Reports an MTG2 LTC2 error • Fail• NoFail

M2DARSErr [RO]

MTG2 DARS Error Reports an MTG2 DARS error • Fail• NoFail

Table 3-3. ACO-3901 Operator and All List Parameters (Continued)

Card-Edge ID Parameter Name Function User Range

or Options

52 ACO-3901 Installation and Operation Manual

Page 71: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

M2Cmp1ErrtoM2Cmp4Err[RO]

MTG2 Composite 1 Error toMTG2 Composite 4 Error

Reports an MTG2 Composite 1 to Composite 4 input error

• Fail• NoFail

ExtImpErr [RO]

External Impulse Error Reports an external impulse error • Fail• NoFail

ExtHzErr [RO]

External Frequency Error

Reports an external frequency error • Fail• NoFail

ExtLTC1Err [RO]

External LTC1 Error Reports an external LTC1 error • Fail• NoFail

ExtLTC2Err [RO]

External LTC2 Error Reports an external LTC2 error • Fail• NoFail

ExtDARSErr [RO]

External DARS Error Reports an external DARS error • Fail• NoFail

ExtCmp1ErrtoExtCmp4Err [RO]

External Composite 1 Error toExternal Composite 4 Error

Reports an external Composite 1 to Composite 4 input error

• Fail• NoFail

OutImpErr [RO]

Output Impulse Error Reports an output impulse error • Fail• NoFail

OutHzErr [RO]

Output Frequency Error

Reports output frequency error • Fail• NoFail

OutLTC1Err [RO]

Output LTC1 Error Reports output LTC1 error • Fail• NoFail

OutLTC2Err [RO]

Output LTC2 Error Reports output LTC2 error • Fail• NoFail

OutDARSErr [RO]

Output DARS Error Reports output DARS error • Fail• NoFail

OutCmp1Err [RO]

Output Composite 1 Error

Reports output Composite 1 to Composite 4 error

• Fail• NoFail

M1VImpErr [RO]

MTG1 Validation Block Impulse Error

Reports MTG1 validation block Impulse Error • Fail• NoFail

Table 3-3. ACO-3901 Operator and All List Parameters (Continued)

Card-Edge ID Parameter Name Function User Range

or Options

ACO-3901 Installation and Operation Manual 53

Page 72: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

M1VHzErr [RO]

MTG1 Validation Block Frequency Error

Reports MTG1 validation block frequency Error

• Fail• NoFail

M1VLTC1Err [RO]

MTG1 Validation Block LTC1 Error

Reports MTG1 validation block LTC1 Error • Fail• NoFail

M1VLTC2Err [RO]

MTG1 Validation Block LTC2 Error

Reports MTG1 validation block LTC2 Error • Fail• NoFail

M1VDARSErr [RO]

MTG1 Validation Block DARS Error

Reports MTG1 validation block DARS Error • Fail• NoFail

M1VCmp1ErrtoM1VCmp4Err [RO]

MTG1 Validation Block Composite 1 to Composite 4 Error

Reports MTG1 validation block Composite 1 to Composite 4 error

• Fail• NoFail

M2VImpErr [RO]

MTG2 Validation Block Impulse Error

Reports MTG2 validation block impulse error • Fail• NoFail

M2VHzErr [RO]

MTG2 Validation Block Frequency Error

Reports MTG2 validation block frequency error

• Fail• NoFail

M2VLTC1Err [RO]

MTG2 Validation Block LTC1 Error

Reports MTG2 validation block LTC1 error • Fail• NoFail

M2VLTC2Err [RO]

MTG2 Validation Block LTC2 Error

Reports MTG2 validation block LTC2 error • Fail• NoFail

M2VDARSErr [RO]

MTG2 Validation Block DARS Error

Reports MTG2 validation block DARS error • Fail• NoFail

M2VCmp1ErrtoM2VCmp4Err [RO]

MTG2 Validation Block Composite 1 Error toMTG2 Validation Block Composite 2 Error

Reports MTG2 validation block Composite 1 to Composite 4 error

• Fail• NoFail

ExVImpErr [RO]

External Validation Block Impulse Error

Reports external validation block impulse error • Fail• NoFail

ExVHzErr [RO]

External Validation Block Frequency Error

Reports external validation block frequency error

• Fail• NoFail

Table 3-3. ACO-3901 Operator and All List Parameters (Continued)

Card-Edge ID Parameter Name Function User Range

or Options

54 ACO-3901 Installation and Operation Manual

Page 73: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

ExVLTC1Err [RO]

External Validation Block LTC1 Error

Reports external validation block LTC1 error • Fail• NoFail

ExVLTC2Err [RO]

External Validation Block LTC2 Error

Reports external validation block LTC2 error • Fail• NoFail

ExVDARSErr [RO]

External Validation Block DARS Error

Reports external validation block DARS error • Fail• NoFail

ExVCmp1Err toExVCmp4Err [RO]

External Validation Block Composite 1 Error toExternal Validation Block Composite 4 Error

Reports external validation block Composite 1 to Composite 4 error

• Fail• NoFail

PrimPSFail [RO]

Primary Power Supply Failure

Indicates whether the primary power supply has failed

• Fail• NoFail

SecPSFail [RO]

Secondary Power Supply Failure

Indicates whether the secondary power supply has failed

• Fail• NoFail

PSFail [RO] Power Supply Failure Indicates whether the power supply has failed • Fail• NoFail

HwFail [RO] Hardware Failure Indicates whether there is a failure in the ACO-3901 module

• Fail• NoFail

FctryRcl[All List only]

Factory Recall Restores factory settings for calibrated parameters

• Yes

• No*

Setup Setup Parameters Sets the parameters for display and usability (see page 81 for a complete list of Setup parameters and their factory default settings)

Various

Table 3-3. ACO-3901 Operator and All List Parameters (Continued)

Card-Edge ID Parameter Name Function User Range

or Options

ACO-3901 Installation and Operation Manual 55

Page 74: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

Setup ParametersYou can modify the Setup parameters to configure the card-edge controls for your personal needs. The Setup section appears at the end of all three navigation lists and consists of these items:• Alarms• Navigation modes• Adjustment modes• Browse modes• Scroll modes• Display intensity• Parameter descriptions• Name• FrameIP• Sync full• About mode

The structure of the Setup menu is located at the end of Appendix A: “Tree View Navigation.” See your NEO FR-3901, FR-3903, and FR-3923 Mounting Frames Installation and Operation Manual for more information on Setup items, including descriptions and operation notes.

NoteSetup parameters on a local or remote control panel may be different from the card-edge parameters described here.

56 ACO-3901 Installation and Operation Manual

Page 75: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

AlarmsThe ACO-3901 has two types of alarms: traditional CCS-enabled alarms, and additional user-configurable hardware alarms.

CCS-Enabled AlarmsACO-3901 modules provide a default list of 70 CCS-enabled alarms. You can disable these alarms by modifying the Alarms parameter in the Setup section.When you select Alarms, the active alarms are visible in the display, below Config (Configurations). If no alarms are active, only Config appears.

Alarm SynchronizationAlarm synchronization is available for this module if your NEO frame contains a 3901RES-E resource module that supports the feature. When active, alarm synchronization ensures that the alarm configuration settings of card-edge controls and the CCS control software and control panels are consistent.If the ACO-3901 module is set for local control, the alarm settings will appear the same at both the card edge and via CCS, but the settings can only be changed using the card-edge controls. If the module is set for remote control, the alarm settings can be changed via both the card edge and CCS control software and control panels.Alarm configuration settings undergo DejaView (state recovery) automatically. This means that when a module is hot-swapped, the alarm configuration for the new module is updated to the settings of the module that was previously in that slot. See “State Recovery Parameter Availability” in this chapter for more information.

Identifying the Cause of an AlarmTo identify the reason for an alarm, select the active alarm, and then press Enter. A scrolling message appears on the VFD describing the cause of the fault.

ACO-3901 Installation and Operation Manual 57

Page 76: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

Enabling or Disabling a CCS Alarm ParameterTo enable or disable an alarm parameter, follow these steps:1. Select Alarms, then select Config, and then press Enter.2. Select one of the alarm parameters, and then press Enter.3. Press Enabled or Disabled. 4. Press Enter to activate the selection.

Restoring Default SettingsTo restore the alarms to their default settings, follow these steps:1. Select Alarms, select Config, and then press Enter.2. Scroll down the list of alarms, and then select Reset.3. Press Enter to activate the selection.

The following table lists the default alarms for the ACO-3901 module. You can enable or disable these settings, but you cannot change the level of the alarm.

Table 3-4. Default CCS-Enabled Alarms for the ACO-3901 Module

Type of Alarm

Card-Edge Alarm Name of Alarm Alarm

Level Meaning of Alarm

Input source problems

MTG1Fail or MTG2Fail

MTG1 or MTG2 Fail Major Loss of MTG1 or MTG2 reference

ExtSrcFail External Source Fail Major Loss of external reference

MonOutFail Monitor Output Fail Major Monitored loss of ACO-3901 output

M1ImpErr MTG1 Impulse Error Major Loss of MTG1 impulse signal

M1HzErr MTG1 Frequency Error Major Loss of MTG1 frequency

M1LTC1Err or M1LTC2Err

MTG1 LTC 1 or LTC 2 Error

Major Loss of MTG1 LTC 1 or 2

M1DARSErr MTG1 DARS Error Major Loss of MTG1 DARS

Input source problems (cont’d)

M1Cmp1Err, M1Cmp2Err, M1Cmp3Err, or M1Cmp4Err

MTG1 Composite 1, 2, 3, or 4 Error

Major Loss of MTG1 Composite 1, 2, 3, or 4 video signal

M2ImpErr MTG21 Impulse Error Major Loss of MTG2 impulse signal

58 ACO-3901 Installation and Operation Manual

Page 77: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

M2HzErr MTG2 Frequency Error Major Loss of MTG2 frequency

M2LTC1Err or M2LTC2Err

MTG2 LTC 1 or LTC 2 Error

Major Loss of MTG2 LTC 1 or 2

M2DARSErr MTG2 DARS Error Major Loss of MTG2 DARS

M2Cmp1Err, M2Cmp2Err,M2Cmp3Err,or M2Cmp4Err

MTG1 Composite 1, 2, 3, or 4 Error

Major Loss of MTG2 Composite 1, 2, 3, or 4 video signal

ExtImpErr External Impulse Error Major Loss of external impulse signal

ExtHzErr External Frequency Error

Major Loss of external frequency

ExtLTC1Err or ExtLTC2Err

External LTC 1 or LTC 2 Error

Major Loss of external LTC 1 or 2

ExtDARSErr External DARS Error Major Loss of external DARS

ExtCmp1Err, ExtCmp2Err, ExtCmp3Err, or ExtCmp4Err

External Composite 1, 2, 3, or 4 Error

Major Loss of external Composite 1, 2, 3, or 4 video signal

Output problems

OutImpErr Output Impulse Error Major Loss of output impulse signal

OutHzErr Output Frequency Error Major Loss of output frequency

OutLTC1Err or OutLTC2Err

Output LTC Error Major Loss of output LTC 1 or 2

OutDARSErr Output DARS Error Major Loss of output DARS

OutCmp1Err, OutCmp2Err, OutCmp3Err, or OutCmp4Err

Output Composite 1, 2, 3, or 4 Error

Major Loss of output Composite 1, 2, 3, or 4 video signal

Validation circuit problems

M1VImpErr MTG1 Validation Impulse Error

Major Loss of MTG1 validation circuit impulse signal

M1VHzErr MTG1 Validation Frequency Error

Major Loss of MTG1 validation circuit frequency

Table 3-4. Default CCS-Enabled Alarms for the ACO-3901 Module (Continued)

Type of Alarm

Card-Edge Alarm Name of Alarm Alarm

Level Meaning of Alarm

ACO-3901 Installation and Operation Manual 59

Page 78: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

M1VLTC1Err or M1VLTC2Err

MTG1 Validation LTC 1 or 2 Error

Major Loss of MTG1validation circuit LTC 1 or 2

M1VDARSErr MTG1 Validation DARS Error

Major Loss of MTG1validation circuit DARS

M1VCmp1Err, M1VCmp2Err, M1VCmp3Err, or M1VCmp4Err

MTG1 Validation Composite 1, 2, 3, or 4 Error

Major Loss of MTG1validation circuit Composite 1, 2, 3, or 4 video signal

M2VImpErr MTG2 Validation Impulse Error

Major Loss of MTG2 validation circuit impulse signal

M2VHzErr MTG2 Validation Frequency Error

Major Loss of MTG2 validation circuit frequency

M2VLTC1Err or M2VLTC2Err

MTG2 Validation LTC 1 or 2 Error

Major Loss of MTG2 validation circuit LTC 1 or 2

M2VDARSErr MTG2 Validation DARS Error

Major Loss of MTG2 validation circuit DARS

M2VCmp1Err, M2VCmp2Err, M2VCmp3Err, or M2VCmp4Err

MTG2 Validation Composite 1, 2, 3, or 4 Error

Major Loss of MTG2 validation circuit Composite 1, 2, 3, or 4 video signal

ExVImpErr External Validation Impulse Error

Major Loss of external validation circuit impulse signal

ExVHzErr External Validation Frequency Error

Major Loss of external validation circuit frequency

ExVLTC1Err or ExVLTC2Err

External Validation LTC 1 or 2 Error

Major Loss of external validation circuit LTC 1 or 2

ExVDARSErr External Validation DARS Error

Major Loss of external validation circuit DARS

Validation circuit problems(cont’d)

ExVCmp1Err, ExVCmp2Err, ExVCmp3Err, or ExVCmp4Err

MTG2 Validation Composite 1, 2, 3, or 4 Error

Major Loss of external validation circuit Composite 1, 2, 3, or 4 video signal

Table 3-4. Default CCS-Enabled Alarms for the ACO-3901 Module (Continued)

Type of Alarm

Card-Edge Alarm Name of Alarm Alarm

Level Meaning of Alarm

60 ACO-3901 Installation and Operation Manual

Page 79: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

Hardware AlarmsThe ACO-3901 has additional hardware alarms that operate independently of the CCS-enabled alarms. Unlike CCS alarms, you can change the Major or Minor designation of the hardware alarms. These alarms are represented by the Major or Minor LEDs located on the left front corner of the ACO-3901 module.The following parameters enable or disable the hardware alarms:• AudPPSEn• AudSPSEn• AudMTG1En• AudMTG2En• AudExtEn• AudOutEn• AudCPUEn• AudM1VBEn• AudM2VBEn• AudExtVBEn

Power supply problems

PrimPSFail Primary Power Supply Fail

Minor Loss of the primary power supply (NEO frame power supply)

SecPSFail Secondary Power Supply Fail

Minor Loss of the secondary power supply (external 24 V source)

PSFail Power Supply Fail Major Loss of the primary power supply (NEO frame power supply) or the secondary power supply (external 24 V source)

Table 3-4. Default CCS-Enabled Alarms for the ACO-3901 Module (Continued)

Type of Alarm

Card-Edge Alarm Name of Alarm Alarm

Level Meaning of Alarm

ACO-3901 Installation and Operation Manual 61

Page 80: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

The following parameters set the level of the hardware alarms:• AlrmPPSEn• AlrmSPSEn• AlrmMTG1En• AlrmMTG2En• AlrmExtEn• AlrmOutEn• AlrmCPUEn• AlrmM1VBEn• AlrmM2VBEn• AlrmExVBEnThese alarms are located on pages 49 to 50 in the Operator and All List Parameters table, and in the Processing>Monitoring section of the Tree View on pages 79 to 80.

State Recovery Parameter AvailabilityThe parameter settings for this module are automatically saved onto the 3901RES-E resource module installed in your NEO frame every five minutes. If a module should fail and be replaced with a cold spare, the state parameters can be automatically recovered. For more information on this feature, see the NEO FR-3901, FR-3903, and FR-3923 Mounting Frames Installation and Operation Manual (Edition E and above).

62 ACO-3901 Installation and Operation Manual

Page 81: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

LED and Module Indicators

General InformationThe ACO-3901 Automatic Changeover Unit has ten card-edge LEDs and five module indicators.The module indicators include a Major Alarm and a Minor Alarm. These alarms alert users to failures or impending failures within the module. They are found in the following locations:• As red or yellow LEDs on the 3901AIC Alarm Interconnect

Module or the 3901RES-E Resource Module (visible via light pipes through the frame’s front panel)

• As part of a list of activated alarms found in the ACO-3901 Setup menu

• In external systems connected to the alarm contact closures at the back of the NEO frames

• On a PC screen where Pilot or another GUI-based control application is being used

The ACO-3901 also has a unique redundant alarm system, in which Major and Minor Alarms are reported in the LEDs. For more details, see page 65.

ACO-3901 Installation and Operation Manual 63

Page 82: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

Card-Edge LocationsFigure 3-1 shows the locations of the LEDs and module indicators on the ACO-3901.

Figure 3-1. Card-edge LEDs and Module Indicators, Top View

Top view

NAV+/NAV- switch(up/down)

Extractor handleESCAPE button

ModuleStatus

MinorAlarm

MajorAlarm Power

SW1

Rem

ote

Loca

l

Nav +Nav -

EnterEsc

MAJORALARM

MINORALARM

POWER MODULESTATUS

Module indicators REMOTE/LOCALswitch

LEDsENTER button

REM LOC

MAJ

OR

_ALR

M (r

ed)

MIN

OR

_ALR

M (a

mbe

r)PR

IM_S

OU

RC

E (g

reen

)BA

K_SO

UR

CE

(gre

en)

EXT_

SOU

RC

E (g

reen

)EX

T_PO

WER

(gre

en)

PRIM

_STA

TUS

(gre

en)

BAK_

STAT

US

(gre

en)

EXT_

STAT

US

(gre

en)

CO

NTR

OL

(gre

en)

64 ACO-3901 Installation and Operation Manual

Page 83: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

LED DescriptionsSee Figure 3-1 on page 64 for the location of the card-edge LEDs described in Table 3-5.

*This alarm operates independently of the CCS-enabled alarms. See page 61 for more information.

Table 3-5. Card-Edge Color and Meaning

LED Color Meaning (When Lit)Major Alarm* Red One of the inputs has failed. (This alarm is

user-configurable.)

Minor Alarm* Amber One of the inputs has failed. (This alarm is user-configurable.)

Primary Source

Green The MTG1 or the CSD1 module (primary source) is active.

Backup Source Green The MTG2 or the CSD2 module (backup source) is active.

External Source

Green The external source is active.

External Power Supply

Green The external power supply is OK.

Primary Status Green The outputs are OK.(If these LEDs are not lit, an error will be reported to a user-configurable Major or Minor Alarm LED listed above.)

Backup Status Green

External Source Status(MTG-3901 or CSD-3902)

Green

Control Green The outputs are operating automatically. (If the LED is off, the control is in manual mode.)

ACO-3901 Installation and Operation Manual 65

Page 84: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 3: Operation

Module Indicators DescriptionsSee Figure 3-1 on page 64 for the location of the module indicators described in Table 3-6.

Table 3-6. Card-Edge Module Indicators

Indicator Color Meaning (when lit)Major Alarm Red A Major alarm has been activated. (See

Table 3-4 on page 58 for possible reasons.)

Minor Alarm Amber A Minor alarm has been activated. (See Table 3-4 on page 58 for possible reasons.)

Power Green The module is receiving power.

Status Green The module is configured, loaded, and operational.

66 ACO-3901 Installation and Operation Manual

Page 85: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 4

Specifications

OverviewThe tables in this chapter list the following specifications for the ACO-3901 module: • “Input” on page 68• “Output” on page 70• “Miscellaneous” on page 71

Specifications and designs are subject to change without notice.

ACO-3901 Installation and Operation Manual 67

Page 86: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 4: Specifications

Input

Analog Video Input

DARS Input

Hz Input

Table 4-1. Analog Video Input Specifications

Item SpecificationMechanical Terminating BNC

Format NTSC/PAL-B/PAL-M/Tri-Level Sync (SMPTE 274M, SMPTE 296M)

Level 1 V pk-to-pk, (600 mV pk-to-pk for TLS)

Table 4-2. DARS Input Specifications

Item SpecificationMechanical Terminating BNC

Format AES: DARS

Level 1 V pk-to-pk, ±10%

Table 4-3. Hz Input Specifications

Item DescriptionMechanical Terminating BNC

Format 1 Hz square wave

Level 5 V TTL-compatible

68 ACO-3901 Installation and Operation Manual

Page 87: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 4: Specifications

LTC InputTable 4-4. LTC Input Specifications

Item DescriptionMechanical DB9

Format LTC 24/25/30 fps drop/non-drop

ACO-3901 Installation and Operation Manual 69

Page 88: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 4: Specifications

Output

Analog Video Output

DARS (Unbalanced) Output

LTC Output

Table 4-5. Analog Video Output Specifications

Item DescriptionMechanical BNC

Format NTSC/PAL-B/PAL-M/Tri-Level

Level 1 V pk-to-pk, (600 mV pk-to-pk for TLS)

Table 4-6. DARS (Unbalanced) Output Specifications

Item DescriptionMechanical BNC

Format AES: DARS

Level 1 V pk-to-pk

Table 4-7. LTC Output Specifications

Item DescriptionElectrical Differential balanced

Mechanical DB9

Format SMPTE/EBU LTC 24/25/30 drop/non-drop support

Impedance Low-Z (< 25Ω per side) or 600Ω, jumper selectable

Level • 3.9 V pk-to-pk nominal into 1 kΩ (Low-Z output)• 2.5 V pk-to-pk nominal into 1 kW

(600Ω output)

Transition time 40µs ± 4µs measured at 10% and 90% amplitude

70 ACO-3901 Installation and Operation Manual

Page 89: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 4: Specifications

Miscellaneous

Changeover Threshold

Isolation

Power Consumption

Table 4-8. Changeover Threshold Specifications

Item DescriptionAnalog color black Sync: -6 dB

Burst: -6 dB

Tri-Level Sync -6 dB

AES -6 dB

LTC -6 dB

Hz -6 dB

Table 4-9. Isolation Specifications

Item DescriptionAll channels, both directions >60 dB (typical)

Table 4-10. Power Consumption Specifications

Item DescriptionACO-3901 module alone <25 W

ACO-3901 with two MTG-3901 or two CSD-3902 modules attached

<75 W

ACO-3901 Installation and Operation Manual 71

Page 90: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Chapter 4: Specifications

72 ACO-3901 Installation and Operation Manual

Page 91: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Appendix A

Tree-View Navigation

OverviewThe Tree View is one of the three navigation modes available on the ACO-3901 module. Unlike the other navigation modes, the Tree View is a multi-level list of parameters, arranged in the following main groups:• “Input” on page 75• “Other” on page 79• “Output” on page 79• “Power” on page 79• “Processing” on page 79• “Setup” on page 80(See page 56 for more information on the Setup parameters which govern the operation of the card-edge controls.)

This appendix consists of instructions for navigating the lists (see page 74) and the Tree View Parameter list.

ACO-3901 Installation and Operation Manual 73

Page 92: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Appendix A: Tree-View Navigation

Navigating the Tree ViewTo navigate and then view or change a parameter from the Tree View, follow these steps:1. Open the front panel of the NEO frame.2. Press any card-edge control to turn on the VFD display.

The message ACO-3901 will appear as the banner on the card-edge display.

3. Press the Enter button.The first two items in the Level One list will appear.

4. Click Nav- (down) on the Nav-/Nav+ switch to view more items in the Level One list.

5. Select the desired item in the Level One list, and then press Enter.This leads you to the Level Two list.

6. Repeat steps 3 and 4 to view more items in Levels Two, Three, and Four.

7. If the parameter is selectable, slide the bar to the desired parameter using the Nav+/Nav-switch.ORSelect the desired item in the Level Four list, and then press Enter.

Once the Level Four parameter is set or viewed, you can leave the parameter in its current state, or return to the banner. To return to the ACO-3901 banner, repeatedly press the Escape button. Close the front panel again after you have completed the procedure to prevent the frame from overheating.

NoteIf you do not wish to make changes to your settings, return to the previously selected item in the list, and then press Escape to move up a level. See SelPar Adj Mode in the Setup section at the end of the Tree View to enable or disable this delayed adjust mode feature.

NoteAfter several seconds of inactivity, a scrolling message will appear, describing the purpose of the currently selected parameter.

74 ACO-3901 Installation and Operation Manual

Page 93: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Appendix A: Tree-View Navigation

Tree View ParametersUnlike the Operator and All List navigation modes, the Tree View is a multi-level structure that includes all of the available card-edge parameters. Parameters with the designation [RO] are “read-only.” An asterisk (*) indicates the default user range or value.See page 74 for instructions on navigating the Tree View.

Input Monitoring

ImpSetFM(Options: SignalLev*, Freq)

HZSetFM (Options: SignalLev*, Freq)

LTC1SetFM and LTC2SetFM(Options: SignalLev*, Format)

DARSSetFM(Options: SignalLev*, Audio)

Cmp1SetFM, Cmp2SetFM, Cmp3SetFM, Cmp4SetFM(Options: SignalLev*, Standard)

Cmp1SrcStd, Cmp2SrcStd, Cmp3SrcStd, Cmp4SrcStd(Options: LR_625, LR_525, LR1080p_23,

LR1080p_24, LR1080p_25, LR1080p_29, LR1080p_30, LR1080i_50, LR1080i_59, LR1080i_60, LR1080f_23, LR1080f_24, Auto*, LR720p_50, LR720p_59, LR720p_60)

M1C1DetStd, M1C2DetStd, M1C3DetStd, or M1C4DetStd [RO](Options: LR_625, LR_525, LR1080p_23,

LR1080p_24, LR1080p_25, LR1080p_29, LR1080p_30, LR1080i_50, LR1080i_59, LR1080i_60, LR1080f_23, LR1080f_24, None, LR720p_50, LR720p_59, LR720p_60)

M2C1DetStd, M2C2DetStd, M2C3DetStd, or M2C4DetStd [RO](Options: LR_625, LR_525, LR1080p_23,

LR1080p_24, LR1080p_25, LR1080p_29, LR1080p_30, LR1080i_50, LR1080i_59, LR1080i_60, LR1080f_23, LR1080f_24, None, LR720p_50, LR720p_59, LR720p_60)

ExC1DetStd, ExC2DetStd, ExC3DetStd, or ExC4DetStd [RO]

ACO-3901 Installation and Operation Manual 75

Page 94: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Appendix A: Tree-View Navigation

(Options: LR_625, LR_525, LR1080p_23, LR1080p_24, LR1080p_25, LR1080p_29, LR1080p_30, LR1080i_50, LR1080i_59, LR1080i_60, LR1080f_23, LR1080f_24,None, LR720p_50, LR720p_59, LR720p_60)

EVal4C1DetStd, Val4C2DetStd, Val4C3DetStd, or Val4C4DetStd [RO](Options: LR_625, LR_525, LR1080p_23,

LR1080p_24, LR1080p_25, LR1080p_29, LR1080p_30, LR1080i_50, LR1080i_59, LR1080i_60, LR1080f_23, LR1080f_24, None, LR720p_50, LR720p_59, LR720p_60)

ImpValEn (Options: Enable, Disable*)

HzValEn(Options: Enable, Disable*)

LTC1ValEn or LTC2ValEn(Options: Enable, Disable*)

DARSValEn(Options: Enable, Disable*)

Cmp1ValEn, Cmp2ValEn, Cmp3ValEn, or Cmp4ValEn(Options: Enable, Disable*)

MTG1Fail or MTG2Fail [RO](Options: On, Off)

ExtSrcFail [RO](Options: On, Off)

M1ImpErr [RO](Options: NoFail, Fail)

M1HzErr [RO](Options: NoFail, Fail)

M1LTC1Err or M1LTC2Err [RO](Options: NoFail, Fail)

M1DARSErr [RO](Options: NoFail, Fail)

M1Cmp1Err, M1Cmp2Err, M1Cmp3Err, orM1Cmp4Err [RO](Options: NoFail, Fail)

M2ImpErr [RO](Options: NoFail, Fail)

M2HzErr [RO](Options: NoFail, Fail)

M2LTC1Err or M2LTC2Err [RO](Options: NoFail, Fail)

M2DARSErr [RO](Options: NoFail, Fail)

M2Cmp1Err, M2Cmp2Err, M2Cmp3Err, or

76 ACO-3901 Installation and Operation Manual

Page 95: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Appendix A: Tree-View Navigation

M2Cmp4Err [RO](Options: NoFail, Fail)

ExtImpErr [RO](Options: NoFail, Fail)

ExtHzErr [RO](Options: NoFail, Fail)

ExtLTC1Err or ExtLTC2Err [RO](Options: NoFail, Fail)

ExtDARSErr [RO](Options: NoFail, Fail)

ExtCmp1Err, ExtCmp2Err, ExtCmp3Err, or ExtCmp4Err [RO](Options: NoFail, Fail)

OutImpErr [RO](Options: NoFail, Fail)

OutHzErr [RO](Options: NoFail, Fail)

OutLTC1Err or OutLTC2Err [RO](Options: NoFail, Fail)

OutDARSErr [RO](Options: NoFail, Fail)

OutCmp1Err, OutCmp2Err, OutCmp3Err, or OutCmp4Err [RO](Options: NoFail, Fail)

M1VImpErr [RO](Options: NoFail, Fail)

M1VHzErr [RO](Options: NoFail, Fail)

M1VLTC1Err or M1VLTC2Err [RO](Options: NoFail, Fail)

M1VDARSErr [RO](Options: NoFail, Fail)

M1VCmp1Err, M1VCmp2Err, M1VCmp3Err, or M1VCmp42Err [RO](Options: NoFail, Fail)

M2VImpErr [RO](Options: NoFail, Fail)

M2VHzErr [RO](Options: NoFail, Fail)

M2VLTC1Err or M2VLTC2Err [RO](Options: NoFail, Fail)

M2VDARSErr [RO](Options: NoFail, Fail)

M2VCmp1Err, M2VCmp2Err, M2VCmp3Err, or M2VCmp4Err [RO](Options: NoFail, Fail)

ACO-3901 Installation and Operation Manual 77

Page 96: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Appendix A: Tree-View Navigation

ExVImpErr [RO](Options: NoFail, Fail)

ExVHzErr [RO](Options: NoFail, Fail)

ExVLTC1Err or ExVLTC2Err [RO](Options: NoFail, Fail)

ExVDARSErr [RO](Options: NoFail, Fail)

ExVCmp1Err, ExVCmp2Err, ExVCmp3Err, or ExVCmp4Err [RO](Options: NoFail, Fail)

Routing GlbSetSrc

(Options: MTG/CSD 1*, MTG/CSD 2, Ext_Src, IndvCtrl)

GlbSrc [RO](Options: Ext_Src, MTG/CSD 1, MTG/CSD 2)

GlbMTG1Ext(Options: MTG/CSD 1*, ExtSrc)

GLBBSetSrc(Options: Auto*, MTG/CSD 1, MTG/CSD 2,

Ext_Src)Val4SetSrc

(Options: Auto*, MTG/CSD 1, MTG/CSD 2, Ext_Src, Outputs)

ImpSetSrc(Options: MTG/CSD 1*, MTG/CSD 2, Ext_Src)

ImpSrc [RO](Options: Ext_Src, MTG/CSD 1, MTG/CSD 2)

HZSetSrc(Options: MTG/CSD 1*, MTG/CSD 2, Ext_Src)

HZSrc [RO](Options: Ext_Src, MTG/CSD 1, MTG/CSD 2)

LTC1SetSrc, LTC2SetSrc(Options: MTG/CSD 1*, MTG/CSD 2, Ext_Src)

LTC1Src, LTC2Src [RO](Options: Ext_Src, MTG/CSD 1, MTG/CSD 2)

DARSSetSrc(Options: MTG/CSD 1*, MTG/CSD 2, Ext_Src)

DARSSrc [RO](Options: Ext_Src, MTG/CSD 1, MTG/CSD 2)

Cmp1SetSrc, Cmp2SetSrc, Cmp3SetSrc, Cmp4SetSrc(Options: MTG/CSD 1*, MTG/CSD 2, Ext_Src)

Cmp1Src, Cmp2Src, Cmp3Src, Cmp4Src [RO]

78 ACO-3901 Installation and Operation Manual

Page 97: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Appendix A: Tree-View Navigation

(Options: Ext_Src, MTG/CSD 1, MTG/CSD 2)ForceRelays

(Options: ACO*, Pass)Other

FctryRcl(Options: Yes, No*)

Output Monitoring

MonOutFail [RO](Options: On, Off)

Power Monitoring

PrimPSFail [RO](Options: On, Off)

SecPSFail [RO](Options: On, Off)

PSFail [RO](Options: On, Off)

Processing Monitoring

AudAlrmTst(Options: Disable*, EnMjrTst, EnMinTst)

AudPPSEn(Options: Enable, Disable*)

AudSPSEn(Options: Enable, Disable*)

AudMTG1En or AudMTG2En(Options: Enable, Disable*)

AudExtEn(Options: Enable, Disable*)

AudOutEn (Options: Enable, Disable*)

AudCPUEn (Options: Enable, Disable*)

AudM1VBEn or AudM2VBEn(Options: Enable, Disable*)

AudExtVBEn(Options: Enable, Disable*)

AlrmPPSEn(Options: Minor*, Major)

AlrmSPSEn(Options: Minor*, Major)

AlrmMTG1En or AlrmMTG2En(Options: Minor*, Major)

ACO-3901 Installation and Operation Manual 79

Page 98: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Appendix A: Tree-View Navigation

AlrmExtEn(Options: Minor*, Major)

AlrmOutEn(Options: Minor*, Major)

AlrmCPUEn(Options: Minor*, Major)

AlrmM1VBEn or AlrmM2VBEn(Options: Minor*, Major)

AlrmExVBEn(Options: Minor*, Major)

GPIPPSEn(Options: Enable*, Disable)

GPISPSEn(Options: Enable*, Disable)

GPIMTG1En or GPIMTG2En(Options: Enable*, Disable)

GPIExtEn(Options: Enable*, Disable)

GPIOutEn(Options: Enable*, Disable)

GPICPUEn(Options: Enable*, Disable)

GPIM1ActEn or GPIM2ActEn(Options: Enable*, Disable)

GPIExActEn(Options: Enable*, Disable)

GPIM1VBEn or GPIM2VBEn(Options: Enable*, Disable)

GPIExtVBEn(Options: Enable*, Disable)

HwFail [RO](Options: On, Off)

Routing GlbSetEnbl

(Options: Enable*, Disable)GlbSetCtrl

(Options: Auto*, Auto-Once, Manual, Reset)GlbSetMode

(Options: Auto*, MTG, CSD)

Setup Alarms

Config Active Alarms

80 ACO-3901 Installation and Operation Manual

Page 99: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Appendix A: Tree-View Navigation

Nav Mode (Navigation Mode)(Options: All List, Tree View, Oper List*)

SelPar Adj (Selectable Parameter Adjust MOde)(Options: Immediate, Delayed*)

Brws Mode (Browse Mode)(Options: Param List, Parm+Val*)

Scrl Mode (Scroll Mode)(Options: Wrap*, Don’t Wrap)

Disp Inten (Display Intensity)(Options: 100%, 50%*, 25%, 12%)

Param Desc (Parameter Description)(Options: Disabled, Enabled*)

NameACO-3901*

Frame IP (*see note for default settings)

(Options: IP Address, Subnet, Gateway)Sync Full

(Options: No*, Yes)About [RO]

(Options: HwID, Sw_Ver)

Note*Default settings for Frame IP options are as follows: IP Address (192.168.100.250), Subnet (255.255.255.0), and Gateway (192.168.100.250).

ACO-3901 Installation and Operation Manual 81

Page 100: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Appendix A: Tree-View Navigation

82 ACO-3901 Installation and Operation Manual

Page 101: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Index

Keywords

AAdd Upgrade Files box 30alarms 57–61, 65–66All List and Operator List 40–55analog video

input specifications 68output specifications 70

Bback module 3–8boot file 28

Ccauses of alarms 57changeover threshold specifications 71Configuration window 31correcting

failed upgrade 28cross-functional parameter changes 36–38CSD-3902 (Clock System Driver) module 2, 19, 22

DDARS

input specifications 68output specifications 70

default settings for alarms 58

DejaView 57disabling or enabling alarms 58, 61drag-and-drop method of upgrading 26

EEMI gaskets 19enabling or disabling alarms 58, 61external

input source 22power supply 23

FFctryRcl parameters 34, 40firmware updating

modules 24–31firmware upgrading 31fl0 folder 31front and rear modules 3–4

GGPO pinouts 34–35

HHz input specifications 68

ACO-3901 Installation and Operation Manual 83

Page 102: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Index

Iidentifying causes of alarm 57impedance jumpers 13–14input pinouts 6, 8input sources 22installing modules 19–21isolation specification 71

Jjumpers 13–18

LLEDs and module indicators 63–66LTC specifications 69, 70

Mmain features 2Manual information vii–xmodule alignment 3–4MTG-3901 (Master Time Generator) module 2, 22MTG-3901 input pinouts 6

Nnavigating parameter lists 39, 74Navigation

Properties box 27, 29, 30

Ooperation notes 34Operator and All List 40–55output pinouts 7, 34

Ppacking list 12parameter lists

Operator and All 40–55Tree View 75–81

parametersFctryRcl 34, 40Setup 56, 81

pinouts 6–8, 34–35power consumption specifications 71Precautions, safety xivProduct servicing xi

Rrebooting the module 31removing ACO-3901 modules 23restoring default settings for alarms 58Returning a product xirevision history viiRoHS-compliance xiiRS-232 pinouts 6

SSafety precautions xivsetting jumpers 13–18Setup parameters 56, 81Shipping and unpacking a product xisignal flow 9software

module upgrading 24–31software upgrading 31specifications

analog video input 68analog video output 70changeover threshold 71DARS input 68DARS output 70Hz input 68isolation 71LTC output 70power consumption 71

StandardsRoHS compliance xiiWEEE compliance xiii

state recovery of alarms 57Support documents x

84 ACO-3901 Installation and Operation Manual

Page 103: ACO-3901 Automatic Changeover Unit Installation and Operation … · 2020. 9. 29. · 1 of 1/December 2006 175-000190-00 Addendum ACO-3901 Automatic Changeover Unit Installation and

Index

synchronizing alarms 57

Ttelco line 17–18Tree View parameter list 75–81

UUnpacking and shipping a product xiupgrading

module software 24–31upgrading firmware 31

VvxWorks.lzs file 28, 31

Wwarranty information iiWEEE compliance xiiiWriting conventions x