SIMATIC WinCC flexible 06-03-2015 - 12:44:03
Screens
\SIMATIC HMI MP277\Screens\OverviewsOverViewUsing template False
Number 0
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
1/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:05
Screens
\SIMATIC HMI MP277\ScreensTemplateUsing template False
Number -1
Visible layer 0
Infotext.
.
Polygon
Name Background fill style Border color Position Size
Template_Polygon Solid 0;0;0 0, 152 639, 323
Ellipse
Name Border color Background color Position Size
Template_Ellipse 0;0;0 255;255;255 32, 24 32, 0
Text Field
4/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:05
Name Text Foreground color Position Size
Template_Text Field FPM 255;255;255 583, 126 46, 31
Template_Text Field_0 M/min 255;255;255 329, 132 40, 20
Template_Text Field_1 M/min 255;255;255 205, 131 40, 20
Template_Text Field_2 M/min 255;255;255 83, 132 40, 20
Template_Text Field_3 FEED ROLLER 255;255;255 246, 102 123, 20
Template_Text Field_4 STRETCH ROLLER 255;255;255 123, 102 123, 20
Template_Text Field_5 0;0;0 104, 1 536, 34
Template_Text Field_6 DELIVERY ROLLER 255;255;255 1, 102 122, 20
Template_Text Field_7 RPM 255;255;255 449, 130 29, 20
Template_Text Field_9 PLASTICIZER 255;255;255 369, 102 112, 20
IO Field
Name Mode Format type Format pattern Authorization
Template_IO Field_0 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = FREQUENCY DRIVE 2 RPM;
Template_IO Field_1 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = MAIN DRIVE RPM;
Template_IO Field_2 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = FREQUENCY DRIVE 1 RPM;
Template_IO Field_4 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = FREQUENCY DRIVE 3 RPM;
Template_IO Field_7 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = PLASTICIZER PUMP RPM;
Graphics View
Name Border color Position Size Graphic
4/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:05
Graphics View 0;0;0 1, 1 103, 33 wnv logo_0
Button
Name Mode Authorization Text OFF Hotkey
Template_Button Graphic Text
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 001_START_SCREEN , Objectnumber = 0 );
Template_Button_0 Graphic Text
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivatePreviousScreen( );
Template_Button_10 Text Heating
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 005_HEATING , Object number = 0);
Template_Button_11 Text RESET
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = SetBitWhileKeyPressed( Tag = RESET PRESS HMI , Bit = 0 );
Template_Button_5 Text Production
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 001_START_SCREEN , Objectnumber = 0 );
Template_Button_6 Text Diagnosis
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 002_DIAGNOSIS , Object number =0 );
Template_Button_7 Text Configuration
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 004_CONFIGURATION , Objectnumber = 0 );
Template_Button_9 Text Operator Panel
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 003_OPERATOR PANEL , Objectnumber = 0 );
Date-Time Field
Name Mode Display system time Show date Show time
Template_Date-Time Field Output True True True
Alarm View
Name Alarm source Line alarm view Position Size
4/3
SIMATIC WinCC flexible 06-03-2015 - 12:44:05
OBJECT_1 Alarms False 0, 35 639, 60
Dynamic
Name = Appearance; State = Enabled; Tag = YELLOW MESSAGE; Start range = 0; End range = 0; Appearance descriptions = Range: 0...0, Foreground Color : 0;0;0, Background Color : 255;255;0, Flashing : No; Data type = Binary; Bit position = 0;
Template_Alarm View Alarms False 0, 35 639, 62
Dynamic
Name = Visibility; State = Enabled; Tag = YELLOW MESSAGE; Data type = Integer; Start range = 0; End range = 0; Bit position = 0;Visibility state = Visible;
Name = Appearance; State = Disabled; Start range = 0; End range = 0; Data type = Integer; Bit position = 0;
Alarm Window
Name Alarm source Line alarm view Position Size
MessageViewAlarms Alarms False 0, 33 640, 143
MessageViewEvents Alarms False 0, 176 640, 150
MessageViewSysmessages Alarms False 0, 102 640, 156
Alarm Indicator
Name Position Size Layer
Template_Alarm Indicator 600, 38 37, 53 0
4/4
SIMATIC WinCC flexible 06-03-2015 - 12:44:08
Screens
\SIMATIC HMI MP277\Screens001_START_SCREENUsing template True
Number 7
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Rectangle
Name Border color Background color Position Size
Rectangle_1 0;0;0 198;198;198 159, 257 30, 30
Dynamic
Name = Appearance; State = Enabled; Tag = ROD DIA HIGH; Start range = 0; End range = 0; Appearance descriptions = Value : 0,Foreground Color : 255;0;0, Background Color : 255;0;0, Flashing : Yes; Data type = Binary; Bit position = 0;
4/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:08
Name Border color Background color Position Size
Rectangle_2 0;0;0 198;198;198 246, 257 30, 30
Dynamic
Name = Appearance; State = Enabled; Tag = ROD DIA STABLE; Start range = 0; End range = 0; Appearance descriptions = Value :0, Foreground Color : 0;255;0, Background Color : 0;255;0, Flashing : No; Data type = Binary; Bit position = 0;
Rectangle_3 0;0;0 198;198;198 330, 257 30, 30
Dynamic
Name = Appearance; State = Enabled; Tag = ROD DIA LOW; Start range = 0; End range = 0; Appearance descriptions = Value : 0,Foreground Color : 255;0;0, Background Color : 255;0;0, Flashing : Yes; Data type = Binary; Bit position = 0;
Text Field
Name Text Foreground color Position Size
Text Field_1 Production 0;0;0 1, 157 127, 45
Text Field_10 Min 239;239;239 600, 292 32, 37
Text Field_11 Total Stop Time 239;239;239 373, 333 140, 37
Text Field_12 Min 239;239;239 600, 332 32, 37
Text Field_13 Runtime After last Stop 239;239;239 373, 373 140, 37
Text Field_14 Min 239;239;239 600, 373 32, 37
Text Field_15 Auto Rod Dia High Stable Low
239;239;239 2, 254 364, 37
Text Field_16 PRODUCTION 255;255;255 104, 1 365, 34
Text Field_18 Perform Rod DiameterLow
255;255;255 3, 334 364, 37
Text Field_2 AUTO SPEED SET POINT FPM
239;239;239 2, 213 364, 37
Text Field_3 Rod Diameter ControlAuto/Manual
255;255;255 3, 374 364, 37
Text Field_4 Perform Rod DiameterHigh
255;255;255 2, 294 364, 37
Text Field_5 Current Production 239;239;239 373, 212 140, 37
Text Field_6 FPM 239;239;239 600, 212 32, 37
Text Field_7 Stopages 239;239;239 373, 253 140, 37
Text Field_8 No 239;239;239 600, 253 32, 37
Text Field_9 AVG Run Time 239;239;239 373, 293 140, 37
4/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:08
Switch
Name Mode Position Size Label text
Switch_1 Switch with text 289, 376 75, 34
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = ROD CONTROL AUTO/MANUAL;
IO Field
Name Mode Format type Format pattern Authorization
OBJECT_22 Output Decimal 9999999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = CURRENT PRODUCTION;
OBJECT_24 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = TOTAL NO OFF STOPS;
OBJECT_25 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = AVERAGE RUNTIME;
OBJECT_357 Input/output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = KDF AUTO SPEED SET POINT;
OBJECT_5 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = TOTAL STOP TIME;
OBJECT_6 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = MACHINE RUNTIME AFTER LAST STOP;
Button
Name Mode Authorization Text OFF Hotkey
Button_1 Text KNIFEADVANCE
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 006_KNIFE ADVANCE , Objectnumber = 0 );
4/3
SIMATIC WinCC flexible 06-03-2015 - 12:44:08
Name Mode Authorization Text OFF Hotkey
Button_2 Text PREVIOUSPRODUCTION
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 007_PREVIOUS PRODUCTION ,Object number = 0 );
Button_3 Text RODDIAMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 008_DIAMETER CONTROL , Objectnumber = 0 );
Button_4 Text TRENDVIEW
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 012_TREND VIEW , Object number= 0 );
Button_5 Graphic Text
Dynamic
Name = Appearance; State = Enabled; Tag = ROD CONTROL PUSH MAXIMUM HMI; Start range = 0; End range = 0; Appearancedescriptions = Range : 0...100, Foreground Color : 0;132;0, Background Color : 0;132;0, Flashing : No; Data type = Integer; Bitposition = 0;
Name = Event; State = Enabled; Property = Press; Function list = SetBitWhileKeyPressed( Tag = ROD CONTROL PUSH MAXIMUMHMI , Bit = 0 );
Button_6 Graphic Text
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = SetBitWhileKeyPressed( Tag = ROD CONTROL PUSH MINIMUMHMI , Bit = 0 );
Name = Appearance; State = Enabled; Tag = ROD CONTROL PUSH MINIMUM HMI; Start range = 0; End range = 0; Appearancedescriptions = Range : 0...100, Foreground Color : 0;132;0, Background Color : 0;132;0, Flashing : No; Data type = Integer; Bitposition = 0;
4/4
SIMATIC WinCC flexible 06-03-2015 - 12:44:10
Screens
\SIMATIC HMI MP277\Screens002_DIAGNOSISUsing template True
Number 23
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Text Field
Name Text Foreground color Position Size
Text Field_1 Diagnosis 0;0;0 130, 157 127, 45
Text Field_16 DIAGNOSIS 255;255;255 104, 1 365, 34
Text Field_2 MESSAGES 255;255;255 3, 219 250, 35
Text Field_3 TEMPERATURE 255;255;255 3, 268 250, 35
3/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:10
Name Text Foreground color Position Size
Text Field_4 PLC DIAGNOSTIC 255;255;255 3, 313 250, 35
Text Field_5 MOTOR STATUS 255;255;255 3, 357 250, 35
Text Field_7 MAIN DRIVE STATUS 255;255;255 326, 221 250, 35
Text Field_8 RUN TIME TERMINATE 255;255;255 326, 267 250, 35
Button
Name Mode Authorization Text OFF Hotkey
Button_1 Text ;;;;;;
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 009_MESSAGES , Object number =0 );
Button_10 Text TRENDVIEW
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 012_TREND VIEW , Object number= 0 );
Button_2 Text ;;;;;;
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 020_DIAGNOSIS TEMPERATURE ,Object number = 0 );
Button_3 Text ;;;;;;
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 021_MAIN DRIVE STATUS , Objectnumber = 0 );
Button_4 Text ;;;;;;
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 013_MOTOR STATUS , Objectnumber = 0 );
Button_5 Text ;;;;;;
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 011_PLC DIAGNOSTIC , Objectnumber = 0 );
Button_6 Text ;;;;;;
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = StopRuntime( Mode = Runtime );
3/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:10
Name Mode Authorization Text OFF Hotkey
Button_7 Text KNIFEADVANCE
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 006_KNIFE ADVANCE , Objectnumber = 0 );
Button_8 Text PREVIOUSPRODUCTION
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 007_PREVIOUS PRODUCTION ,Object number = 0 );
Button_9 Text RODDIAMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 008_DIAMETER CONTROL , Objectnumber = 0 );
3/3
SIMATIC WinCC flexible 06-03-2015 - 12:44:13
Screens
\SIMATIC HMI MP277\Screens003_OPERATOR PANELUsing template True
Number 24
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Text Field
Name Text Foreground color Position Size
Text Field_1 Operator Panel 0;0;0 258, 157 127, 45
Text Field_10 HEAD AND DRUMCLEANING
255;255;255 6, 342 310, 50
Dynamic
Name = Appearance; State = Enabled; Tag = HEAD AND DRUM CLEAN ON; Start range = 0; End range = 0; Appearance descriptions= Value : 0, Foreground Color : 255;255;255, Background Color : 49;49;49, Flashing : Yes; Data type = Binary; Bit position = 0;
3/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:13
Name Text Foreground color Position Size
Text Field_11 AUXILIARY MOTORS 255;255;255 325, 341 310, 50
Dynamic
Name = Appearance; State = Enabled; Tag = AUXILIARY MOTORS RUNNING; Start range = 0; End range = 0; Appearancedescriptions = Value : 0, Foreground Color : 255;255;255, Background Color : 49;49;49, Flashing : Yes; Data type = Binary; Bitposition = 0;
Text Field_16 OPERATOR PANEL 255;255;255 104, 1 365, 34
Text Field_5 GLUE NOZZLE 255;255;255 325, 233 310, 50
Dynamic
Name = Appearance; State = Enabled; Tag = GLUE NOZZLE ON HMI; Start range = 0; End range = 0; Appearance descriptions =Value : 0, Foreground Color : 255;255;255, Background Color : 49;49;49, Flashing : Yes; Data type = Binary; Bit position = 0;
Text Field_7 TRANSPORT JET 255;255;255 325, 287 310, 50
Dynamic
Name = Appearance; State = Enabled; Tag = T JET SET HMI; Start range = 0; End range = 0; Appearance descriptions = Value : 0,Foreground Color : 255;255;255, Background Color : 49;49;49, Flashing : Yes; Data type = Binary; Bit position = 0;
Text Field_8 BRUSH MOTOR 255;255;255 6, 233 310, 50
Dynamic
Name = Appearance; State = Enabled; Tag = BRUSH MOTOR ON/OFF; Start range = 0; End range = 0; Appearance descriptions =Value : 0, Foreground Color : 255;255;255, Background Color : 49;49;49, Flashing : Yes; Data type = Binary; Bit position = 0;
Text Field_9 DRY SAMPLING 255;255;255 6, 287 310, 50
Dynamic
Name = Appearance; State = Enabled; Tag = DRY SAMPLING SET; Start range = 0; End range = 0; Appearance descriptions = Value: 0, Foreground Color : 255;255;255, Background Color : 49;49;49, Flashing : Yes; Data type = Binary; Bit position = 0;
Button
Name Mode Authorization Text OFF Hotkey
Button_11 Graphic Text
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = SetBitWhileKeyPressed( Tag = T JET JOG BIT , Bit = 0 );
Button_18 Graphic Text
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = SetBitWhileKeyPressed( Tag = HEAD AND DRUM CLEAN , Bit = 0 );
Button_19 Graphic Text
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = SetBitWhileKeyPressed( Tag = DRY SAMPLING SET , Bit = 0 );
3/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:13
Name Mode Authorization Text OFF Hotkey
Button_23 Text l
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = SetBit( Tag = GLUE NOZZLE ON HMI );
Button_24 Text O
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = ResetBit( Tag = GLUE NOZZLE ON HMI );
Button_27 Text l
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = SetBit( Tag = T JET SET HMI );
Button_28 Text O
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = ResetBit( Tag = T JET SET HMI );
Button_29 Text l
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = SetBit( Tag = BRUSH MOTOR ON/OFF );
Button_30 Text O
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = ResetBit( Tag = BRUSH MOTOR ON/OFF );
Button_31 Text l
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = SetBitWhileKeyPressed( Tag = AUXILIARY MOTORS , Bit = 0 );
Button_32 Text O
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = SetBitWhileKeyPressed( Tag = AUXILIARY MOTORS STOP HMI , Bit= 0 );
Template_Button_11 Text TPU POTENTIOMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 022_TPU POTENTIOMETER , Objectnumber = 0 );
3/3
SIMATIC WinCC flexible 06-03-2015 - 12:44:15
Screens
\SIMATIC HMI MP277\Screens004_CONFIGURATIONUsing template True
Number 25
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Text Field
Name Text Foreground color Position Size
Text Field_1 CONFIGURATION 0;0;0 385, 157 127, 45
Text Field_16 CONFIGURATION 255;255;255 104, 1 365, 34
Text Field_2 FM & TPU TimerConfiguration
255;255;255 96, 224 376, 35
3/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:15
Name Text Foreground color Position Size
Text Field_4 Splicing SequenceConfiguration
255;255;255 96, 265 376, 35
Text Field_6 PLC Time & HMI DeviceConfiguration
255;255;255 96, 306 376, 35
Button
Name Mode Authorization Text OFF Hotkey
Button_1 Text ;;;;;;
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 014_FM & TPU TIMER , Objectnumber = 0 );
Button_2 Text KNIFEADVANCE
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 006_KNIFE ADVANCE , Objectnumber = 0 );
Button_3 Text PREVIOUSPRODUCTION
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 007_PREVIOUS PRODUCTION ,Object number = 0 );
Button_4 Text RODDIAMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 008_DIAMETER CONTROL , Objectnumber = 0 );
Button_5 Text ;;;;;;
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 016_SPLICING CONFIGURATION ,Object number = 0 );
Button_6 Text TRENDVIEW
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 012_TREND VIEW , Object number= 0 );
Button_7 Text ;;;;;;
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 019_PLC & HMI CONFIGURATION ,Object number = 0 );
3/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:15
Name Mode Authorization Text OFF Hotkey
Template_Button_11 Text TPU POTENTIOMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 022_TPU POTENTIOMETER , Objectnumber = 0 );
3/3
SIMATIC WinCC flexible 06-03-2015 - 12:44:18
Screens
\SIMATIC HMI MP277\Screens005_HEATINGUsing template True
Number 4
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Text Field
Name Text Foreground color Position Size
Text Field_1 Tank Chamber Heater 255;255;255 4, 208 506, 43
Text Field_13 o 255;255;255 328, 210 11, 20
Text Field_14 o 255;255;255 327, 262 11, 20
Text Field_15 o 255;255;255 327, 310 11, 20
4/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:18
Name Text Foreground color Position Size
Text Field_16 o 255;255;255 328, 358 11, 20
Text Field_17 o 255;255;255 477, 359 11, 20
Text Field_18 o 255;255;255 477, 263 11, 20
Text Field_19 o 255;255;255 477, 311 11, 20
Text Field_2 Heating 0;0;0 512, 157 127, 45
Text Field_20 HEATING 255;255;255 104, 1 365, 34
Text Field_21 SV 255;255;255 223, 218 23, 25
Text Field_24 SV 255;255;255 223, 267 23, 25
Text Field_25 SV 255;255;255 223, 317 23, 25
Text Field_26 SV 255;255;255 223, 366 23, 25
Text Field_27 PV 255;255;255 371, 218 23, 25
Text Field_3 PZ Tank Level 255;255;255 517, 397 119, 23
Text Field_30 PV 255;255;255 371, 267 23, 25
Text Field_31 PV 255;255;255 371, 317 23, 25
Text Field_32 PV 255;255;255 371, 367 23, 25
Text Field_33 C 255;255;255 332, 219 14, 25
Text Field_36 C 255;255;255 332, 271 14, 25
Text Field_37 C 255;255;255 332, 320 14, 25
Text Field_38 C 255;255;255 332, 369 14, 25
Text Field_39 C 255;255;255 482, 220 14, 25
Text Field_42 C 255;255;255 482, 270 14, 25
Text Field_43 C 255;255;255 482, 319 14, 25
Text Field_44 C 255;255;255 482, 369 14, 25
Text Field_5 Hose Pipe Heater 255;255;255 4, 257 506, 43
Text Field_6 Hot Melt Nozzel Heater 255;255;255 4, 306 506, 43
4/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:18
Name Text Foreground color Position Size
Text Field_7 Rod Chamber Heater 255;255;255 4, 355 506, 43
Text Field_8 o 255;255;255 478, 210 11, 20
IO Field
Name Mode Format type Format pattern Authorization
OBJECT_16 Output Decimal 999.9
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = TANK CHAMBER HEATER PV;
Name = Appearance; State = Enabled; Tag = TANK CHAMBER HEATER PV; Start range = 0; End range = 0; Appearance descriptions= Value : 0, Foreground Color : 0;0;0, Background Color : 255;0;0, Flashing : No; Data type = Integer; Bit position = 0;
OBJECT_18 Output Decimal 999.9
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = HOT MELT NOZZLE HEATER PV;
Name = Appearance; State = Enabled; Tag = HOT MELT NOZZLE HEATER PV; Start range = 0; End range = 0; Appearancedescriptions = Value : 0, Foreground Color : 0;0;0, Background Color : 255;0;0, Flashing : No; Data type = Integer; Bit position = 0;
OBJECT_180 Output Decimal 999.9
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = ROD CHAMBER HEATER PV;
Name = Appearance; State = Enabled; Tag = ROD CHAMBER HEATER PV; Start range = 0; End range = 0; Appearance descriptions= Value : 0, Foreground Color : 0;0;0, Background Color : 255;0;0, Flashing : No; Data type = Integer; Bit position = 0;
OBJECT_30 Input/output Decimal 999.9
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = ROD CHAMBER HEATER SV;
OBJECT_32 Input/output Decimal 999.9
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = TANK CHAMBER HEATER SV;
OBJECT_35 Input/output Decimal 999.9
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = HOT MELT NOZZLE HEATER SV;
OBJECT_36 Output Decimal 999.9
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = HOSE PIPE HEATER PV;
Name = Appearance; State = Enabled; Tag = HOSE PIPE HEATER PV; Start range = 0; End range = 0; Appearance descriptions =Value : 0, Foreground Color : 0;0;0, Background Color : 255;0;0, Flashing : No; Data type = Integer; Bit position = 0;
4/3
SIMATIC WinCC flexible 06-03-2015 - 12:44:18
Name Mode Format type Format pattern Authorization
OBJECT_37 Input/output Decimal 999.9
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = HOSE PIPE HEATER SV;
Button
Name Mode Authorization Text OFF Hotkey
Button_1 Text KNIFEADVANCE
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 006_KNIFE ADVANCE , Objectnumber = 0 );
Button_2 Text PREVIOUSPRODUCTION
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 007_PREVIOUS PRODUCTION ,Object number = 0 );
Button_3 Text RODDIAMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 008_DIAMETER CONTROL , Objectnumber = 0 );
Button_4 Text TRENDVIEW
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 012_TREND VIEW , Object number= 0 );
Bar
Name Minimum value Maximum value Position Size
Bar_1 0 100 520, 208 112, 191
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = PLASTICIZER TANK LEVEL;
4/4
SIMATIC WinCC flexible 06-03-2015 - 12:44:21
Screens
\SIMATIC HMI MP277\Screens006_KNIFE ADVANCEUsing template True
Number 6
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Text Field
Name Text Foreground color Position Size
Text Field_1 Cuts/Per kinfe Advance Fil Actual Cuts
255;255;255 4, 228 628, 42
Text Field_16 KNIFE ADVANCECOUNTING
255;255;255 104, 1 365, 34
Text Field_2 Number of Knife Advances 255;255;255 4, 274 408, 42
3/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:21
Name Text Foreground color Position Size
Text Field_3 Filter Knife End Alarm No.
255;255;255 4, 319 408, 42
Text Field_4 Filter Knife End Stop No.
255;255;255 4, 364 408, 42
Text Field_6 Production 0;0;0 1, 157 127, 45
Text Field_7 No. 255;255;255 378, 281 29, 25
IO Field
Name Mode Format type Format pattern Authorization
IO Field_1 Input/output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = FILTER KNIFE END ALARM;
IO Field_2 Input/output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = FILTER KNIFE END STOP;
IO Field_6 Input/output Decimal 99999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = CUT/PER KNIFE ADVANCE;
IO Field_7 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = NUMBER OF KNIFE ADVANCE COUNTING;
IO Field_8 Output Decimal 99999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = ACTUAL CUTS;
Button
Name Mode Authorization Text OFF Hotkey
Button_1 Text MANUAL KNIFE ADVANCE
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = SetBitWhileKeyPressed( Tag = KNIFE ADVANCE HMI , Bit = 0 );
3/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:21
Name Mode Authorization Text OFF Hotkey
Button_3 Text PREVIOUSPRODUCTION
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 007_PREVIOUS PRODUCTION ,Object number = 0 );
Button_4 Text RODDIAMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 008_DIAMETER CONTROL , Objectnumber = 0 );
Button_5 Text TRENDVIEW
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 012_TREND VIEW , Object number= 0 );
Button_8 Text RESET KNIFE
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = SetBitWhileKeyPressed( Tag = KNIFE RESET HMI , Bit = 0 );
3/3
SIMATIC WinCC flexible 06-03-2015 - 12:44:23
Screens
\SIMATIC HMI MP277\Screens007_PREVIOUS PRODUCTIONUsing template True
Number 9
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Rectangle
Name Border color Background color Position Size
Rectangle_1 0;0;0 132;132;132 0, 215 640, 208
Rectangle_2 0;0;0 148;148;148 160, 425 314, 50
Line
Name Color Background color Position Size
Line_2 0;0;0 255;255;255 0, 267 640, 0
4/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:23
Name Color Background color Position Size
Line_3 0;0;0 255;255;255 0, 319 640, 0
Line_4 0;0;0 255;255;255 0, 371 640, 0
Line_5 0;0;0 255;255;255 131, 216 0, 208
Line_6 0;0;0 255;255;255 259, 216 0, 208
Line_7 0;0;0 255;255;255 386, 216 0, 208
Line_8 0;0;0 255;255;255 512, 216 0, 208
Text Field
Name Text Foreground color Position Size
Text Field_1 Description 255;255;255 3, 217 126, 48
Text Field_11 Production 0;0;0 1, 157 127, 45
Text Field_16 PREVIOUS PRODUCTION 255;255;255 104, 1 365, 34
Text Field_2 1ST SHIFT0600-1400
255;255;255 3, 269 126, 48
Text Field_3 2ND SHIFT1400-2200
255;255;255 3, 321 126, 48
Text Field_4 3RD SHIFT2200-0600
255;255;255 3, 372 126, 48
Text Field_5 PRODUCTION(Nos)
255;255;255 134, 217 122, 48
Text Field_6 AVG RUNTIME(Mins)
255;255;255 388, 217 122, 48
Text Field_7 STOPAGES(Nos)
255;255;255 261, 217 122, 48
Text Field_8 AVG RUN TIME OF 3SHIFTS (Mins)
255;255;255 165, 428 221, 45
Text Field_9 STOP TIME(Mins)
255;255;255 515, 217 122, 48
IO Field
Name Mode Format type Format pattern Authorization
4/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:23
Name Mode Format type Format pattern Authorization
OBJECT_24 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = 3RD SHIFT PREVIOUS STOPAGES;
OBJECT_25 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = 2ND SHIFT PREVIOUS STOPAGES;
OBJECT_26 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = 1st SHIFT PREVIOUS STOPAGES;
OBJECT_27 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = 1ST SHIFT PREVIOUS AVG RUNTIME;
OBJECT_28 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = 2ND SHIFT PREVIOUS AVG RUNTIME;
OBJECT_284 Output Decimal 99999999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = 3RD SHIFT PREVIOUS PRODUCTION;
OBJECT_285 Output Decimal 99999999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = 2ND SHIFT PREVIOUS PRODUCTION;
OBJECT_286 Output Decimal 99999999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = 1ST SHIFT PREVIOUS PRODUCTION;
OBJECT_29 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = 1ST SHIFT STOP TIME;
OBJECT_30 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = 3RD SHIFT PREVIOUSAVG RUNTIME;
4/3
SIMATIC WinCC flexible 06-03-2015 - 12:44:23
Name Mode Format type Format pattern Authorization
OBJECT_31 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = 2ND SHIFT STOP TIME;
OBJECT_32 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = 3RD SHIFT STOP TIME;
OBJECT_33 Output Decimal 9999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = TOTAL AVG RUNTIME 3 SHIFTS;
4/4
SIMATIC WinCC flexible 06-03-2015 - 12:44:26
Screens
\SIMATIC HMI MP277\Screens008_DIAMETER CONTROLUsing template True
Number 10
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Rectangle
Name Border color Background color Position Size
Rectangle_1 0;0;0 198;198;198 570, 255 40, 33
Dynamic
Name = Appearance; State = Enabled; Tag = ROD DIA HIGH; Start range = 0; End range = 0; Appearance descriptions = Value : 0,Foreground Color : 255;0;0, Background Color : 255;0;0, Flashing : Yes; Data type = Binary; Bit position = 0;
3/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:26
Name Border color Background color Position Size
Rectangle_2 0;0;0 198;198;198 571, 308 40, 33
Dynamic
Name = Appearance; State = Enabled; Tag = ROD DIA STABLE; Start range = 0; End range = 0; Appearance descriptions = Value :0, Foreground Color : 0;255;0, Background Color : 0;255;0, Flashing : No; Data type = Binary; Bit position = 0;
Rectangle_3 0;0;0 198;198;198 571, 361 40, 33
Dynamic
Name = Appearance; State = Enabled; Tag = ROD DIA LOW; Start range = 0; End range = 0; Appearance descriptions = Value : 0,Foreground Color : 255;0;0, Background Color : 255;0;0, Flashing : Yes; Data type = Binary; Bit position = 0;
Rectangle_4 0;0;0 206;206;115 443, 215 182, 192
Text Field
Name Text Foreground color Position Size
Text Field_1 Perform Rod DiameterHigh
255;255;255 13, 223 382, 54
Text Field_15 High 255;255;255 456, 251 159, 42
Text Field_16 ROD DIAMETER 255;255;255 104, 1 365, 34
Text Field_17 Stable 255;255;255 456, 304 159, 42
Text Field_18 Low 255;255;255 456, 357 159, 42
Text Field_2 Perform Rod DiameterLow
255;255;255 13, 284 382, 54
Text Field_3 Rod Diameter ControlAuto/Manual
255;255;255 13, 345 382, 54
Text Field_4 Auto Rod Dia Status 0;0;0 450, 220 169, 23
Text Field_5 Production 0;0;0 1, 157 127, 45
Switch
Name Mode Position Size Label text
Switch_1 Switch with text 314, 347 80, 50
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = ROD CONTROL AUTO/MANUAL;
Button
Name Mode Authorization Text OFF Hotkey
3/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:26
Name Mode Authorization Text OFF Hotkey
Button_1 Text KNIFEADVANCE
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 006_KNIFE ADVANCE , Objectnumber = 0 );
Button_2 Graphic Text
Dynamic
Name = Appearance; State = Enabled; Tag = ROD CONTROL PUSH MAXIMUM HMI; Start range = 0; End range = 0; Appearancedescriptions = Range : 0...100, Foreground Color : 0;132;0, Background Color : 0;132;0, Flashing : No; Data type = Integer; Bitposition = 0;
Name = Event; State = Enabled; Property = Press; Function list = SetBitWhileKeyPressed( Tag = ROD CONTROL PUSH MAXIMUMHMI , Bit = 0 );
Button_3 Text PREVIOUSPRODUCTION
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 007_PREVIOUS PRODUCTION ,Object number = 0 );
Button_4 Graphic Text
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = SetBitWhileKeyPressed( Tag = ROD CONTROL PUSH MINIMUMHMI , Bit = 0 );
Name = Appearance; State = Enabled; Tag = ROD CONTROL PUSH MINIMUM HMI; Start range = 0; End range = 0; Appearancedescriptions = Range : 0...100, Foreground Color : 0;132;0, Background Color : 0;132;0, Flashing : No; Data type = Integer; Bitposition = 0;
Button_6 Text TRENDVIEW
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 012_TREND VIEW , Object number= 0 );
3/3
SIMATIC WinCC flexible 06-03-2015 - 12:44:28
Screens
\SIMATIC HMI MP277\Screens009_MESSAGESUsing template True
Number 1
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Text Field
Name Text Foreground color Position Size
Text Field_1 Diagnosis 0;0;0 130, 157 127, 45
Text Field_16 MESSAGES 255;255;255 104, 1 365, 34
Button
Name Mode Authorization Text OFF Hotkey
2/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:28
Name Mode Authorization Text OFF Hotkey
Button_1 Text SystemMessages
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 010_SYSTEM MESSAGES , Objectnumber = 0 );
OBJECT Text Message Buffer
Dynamic
Name = Event; State = Enabled; Property = Release; Function list = ShowAlarmWindow( Object name = MessageViewSysmessages ,Display mode = Toggle );
OBJECT_308 Text DeleteBuffer
Dynamic
Name = Event; State = Enabled; Property = Release; Function list = ClearAlarmBufferProtoolLegacy( Alarm class number = Allalarms/events );
Alarm View
Name Alarm source Line alarm view Position Size
OBJECT_187 Alarms False 0, 215 640, 208
2/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:30
Screens
\SIMATIC HMI MP277\Screens010_SYSTEM MESSAGESUsing template True
Number 2
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Text Field
Name Text Foreground color Position Size
Text Field_1 Diagnosis 0;0;0 130, 157 127, 45
Text Field_16 SYSTEM MESSAGES 255;255;255 104, 1 365, 34
Button
Name Mode Authorization Text OFF Hotkey
2/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:30
Name Mode Authorization Text OFF Hotkey
Button_1 Text KNIFEADVANCE
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 006_KNIFE ADVANCE , Objectnumber = 0 );
Button_2 Text PREVIOUSPRODUCTION
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 007_PREVIOUS PRODUCTION ,Object number = 0 );
Button_3 Text RODDIAMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 008_DIAMETER CONTROL , Objectnumber = 0 );
Button_4 Text TRENDVIEW
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 012_TREND VIEW , Object number= 0 );
Alarm View
Name Alarm source Line alarm view Position Size
OBJECT_14 Alarms False 0, 215 640, 208
2/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:33
Screens
\SIMATIC HMI MP277\Screens011_PLC DIAGNOSTICUsing template True
Number 5
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Text Field
Name Text Foreground color Position Size
Text Field_1 Diagnosis 0;0;0 130, 157 127, 45
Text Field_16 PLC DIAGNOSTIC 255;255;255 104, 1 365, 34
Button
Name Mode Authorization Text OFF Hotkey
2/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:33
Name Mode Authorization Text OFF Hotkey
Button_1 Text KNIFEADVANCE
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 006_KNIFE ADVANCE , Objectnumber = 0 );
Button_2 Text PREVIOUSPRODUCTION
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 007_PREVIOUS PRODUCTION ,Object number = 0 );
Button_3 Text RODDIAMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 008_DIAMETER CONTROL , Objectnumber = 0 );
Button_4 Text TRENDVIEW
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 012_TREND VIEW , Object number= 0 );
Status Force
Name PLC type Position Size Set of visible columns
StatusForce S7_300/400 0, 216 639, 208 Connection ,Type ,DBnumber ,Offset ,Bit ,Datatype ,Format ,Status value,Control value
2/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:35
Screens
\SIMATIC HMI MP277\Screens012_TREND VIEWUsing template True
Number 3
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Text Field
Name Text Foreground color Position Size
Text Field_16 TREND VIEW 255;255;255 104, 1 365, 34
Text Field_2 Production 0;0;0 2, 157 127, 45
Button
Name Mode Authorization Text OFF Hotkey
2/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:35
Name Mode Authorization Text OFF Hotkey
Button_1 Text KNIFEADVANCE
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 006_KNIFE ADVANCE , Objectnumber = 0 );
Button_2 Text PREVIOUSPRODUCTION
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 007_PREVIOUS PRODUCTION ,Object number = 0 );
Button_3 Text RODDIAMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 008_DIAMETER CONTROL , Objectnumber = 0 );
Trend View
Name Position Size Trends Display value table
OBJECT_184 2, 216 636, 207 CURVE (Display=Bars,Line=Solid, Side=Right,Samples=999, Barwidth=50, Trendtype=Realtime cyclictriggered, Trendtag=CURRENTPRODUCTION,Cyclic=90.0000000000000000000, Statuscolor=Color [A=255, R=0,G=0, B=255], Foregroundcolor=Color [A=255, R=0,G=0, B=0], Upper limitcolor=Color [A=255,R=255, G=255, B=0],Lower limit color=Color[A=255, R=255, G=0,B=0])
False
2/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:38
Screens
\SIMATIC HMI MP277\Screens013_MOTOR STATUSUsing template True
Number 15
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Text Field
Name Text Foreground color Position Size
OBJECT Main Drive 255;255;255 2, 212 208, 50
Dynamic
Name = Appearance; State = Enabled; Tag = MAIN DRIVE RUNNING; Start range = 0; End range = 0; Appearance descriptions =Value : 0, Foreground Color : 206;0;0, Background Color : 0;132;0, Flashing : Yes; Data type = Binary; Bit position = 0;
3/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:38
Name Text Foreground color Position Size
OBJECT_20 Knife Grinding Motor 255;255;255 215, 212 208, 50
Dynamic
Name = Appearance; State = Enabled; Tag = AUXILIARY MOTORS RUNNING; Start range = 0; End range = 0; Appearancedescriptions = Value : 0, Foreground Color : 206;0;0, Background Color : 0;132;0, Flashing : Yes; Data type = Binary; Bit position =0;
OBJECT_22 Blower Motor 255;255;255 2, 370 208, 50
Dynamic
Name = Appearance; State = Enabled; Tag = AUXILIARY MOTORS RUNNING; Start range = 0; End range = 0; Appearancedescriptions = Value : 0, Foreground Color : 206;0;0, Background Color : 0;132;0, Flashing : Yes; Data type = Binary; Bit position =0;
OBJECT_24 Oil Pump Motor 255;255;255 215, 370 208, 50
Dynamic
Name = Appearance; State = Enabled; Tag = AUXILIARY MOTORS RUNNING; Start range = 0; End range = 0; Appearancedescriptions = Value : 0, Foreground Color : 206;0;0, Background Color : 0;132;0, Flashing : Yes; Data type = Binary; Bit position =0;
OBJECT_28 Brush Drive 255;255;255 2, 266 208, 50
Dynamic
Name = Appearance; State = Enabled; Tag = BRUSH MOTOR RUNNING; Start range = 0; End range = 0; Appearance descriptions =Value : 0, Foreground Color : 206;0;0, Background Color : 0;132;0, Flashing : Yes; Data type = Binary; Bit position = 0;
OBJECT_30 DRIVE 1-2-3 255;255;255 428, 266 208, 50
Dynamic
Name = Appearance; State = Enabled; Tag = DRIVE 1-2-3 RUNNING; Start range = 0; End range = 0; Appearance descriptions =Value : 0, Foreground Color : 206;0;0, Background Color : 0;132;0, Flashing : Yes; Data type = Binary; Bit position = 0;
OBJECT_32 Plasticizer Drive 255;255;255 2, 318 208, 50
Dynamic
Name = Appearance; State = Enabled; Tag = PLASTICIZER DRIVE RUNNING; Start range = 0; End range = 0; Appearancedescriptions = Value : 0, Foreground Color : 206;0;0, Background Color : 0;132;0, Flashing : Yes; Data type = Binary; Bit position =0;
OBJECT_34 Comperessor 255;255;255 428, 212 208, 50
Dynamic
Name = Appearance; State = Enabled; Tag = COMPRESSOR RUNNING; Start range = 0; End range = 0; Appearance descriptions =Value : 0, Foreground Color : 206;0;0, Background Color : 0;132;0, Flashing : Yes; Data type = Binary; Bit position = 0;
OBJECT_38 Bobbin Change Motor 255;255;255 215, 266 208, 50
Dynamic
Name = Appearance; State = Enabled; Tag = BOBBIN CHANGE MOTOR; Start range = 0; End range = 0; Appearance descriptions =Value : 0, Foreground Color : 206;0;0, Background Color : 0;132;0, Flashing : Yes; Data type = Binary; Bit position = 0;
3/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:38
Name Text Foreground color Position Size
OBJECT_40 Chiller Unit 255;255;255 215, 318 208, 50
Dynamic
Name = Appearance; State = Enabled; Tag = AUXILIARY MOTORS RUNNING; Start range = 0; End range = 0; Appearancedescriptions = Value : 0, Foreground Color : 206;0;0, Background Color : 0;132;0, Flashing : Yes; Data type = Binary; Bit position =0;
Text Field_1 Diagnosis 0;0;0 130, 157 127, 45
Text Field_16 MOTOR STATUS 255;255;255 104, 1 365, 34
Button
Name Mode Authorization Text OFF Hotkey
Button_1 Text KNIFEADVANCE
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 006_KNIFE ADVANCE , Objectnumber = 0 );
Button_2 Text PREVIOUSPRODUCTION
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 007_PREVIOUS PRODUCTION ,Object number = 0 );
Button_3 Text RODDIAMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 008_DIAMETER CONTROL , Objectnumber = 0 );
Button_4 Text TRENDVIEW
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 012_TREND VIEW , Object number= 0 );
Template_Button_11 Text TPU POTENTIOMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 022_TPU POTENTIOMETER , Objectnumber = 0 );
3/3
SIMATIC WinCC flexible 06-03-2015 - 12:44:40
Screens
\SIMATIC HMI MP277\Screens014_FM & TPU TIMERUsing template True
Number 11
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Text Field
Name Text Foreground color Position Size
Text Field_1 CONFIGURATION 0;0;0 385, 157 127, 45
Text Field_14 PRE TENSTION ROLLEROFF DELAY T14 Sec
255;255;255 4, 235 508, 40
Text Field_16 FM & TPU TIMER 255;255;255 104, 1 365, 34
2/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:40
Name Text Foreground color Position Size
Text Field_2 TRANSPORT JET OFFDELAY T1 Sec
255;255;255 4, 282 508, 40
IO Field
Name Mode Format type Format pattern Authorization
IO Field_1 Input/output Decimal 999999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = PRE TENSTION ROLLER OFF DELAY;
IO Field_2 Input/output Decimal 999999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = TRANSPORT JET OFF DELAY;
Button
Name Mode Authorization Text OFF Hotkey
Button_1 Text KNIFEADVANCE
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 006_KNIFE ADVANCE , Objectnumber = 0 );
Button_2 Text PREVIOUSPRODUCTION
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 007_PREVIOUS PRODUCTION ,Object number = 0 );
Button_3 Text RODDIAMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 008_DIAMETER CONTROL , Objectnumber = 0 );
Button_4 Text TRENDVIEW
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 012_TREND VIEW , Object number= 0 );
2/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:43
Screens
\SIMATIC HMI MP277\Screens016_SPLICING CONFIGURATIONUsing template True
Number 16
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Text Field
Name Text Foreground color Position Size
Text Field_1 CONFIGURATION 0;0;0 385, 157 127, 45
Text Field_10 Right Bobbin End OffDelay Sec
255;255;255 63, 298 510, 40
Text Field_16 SPLICING SEQUENCE 255;255;255 104, 1 365, 34
2/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:43
Name Text Foreground color Position Size
Text Field_2 Sec 255;255;255 531, 305 28, 23
Text Field_3 Sec 255;255;255 531, 257 28, 23
Text Field_9 Left Bobbin Diameter Falls250 mm Off Delay Sec
255;255;255 63, 250 510, 40
IO Field
Name Mode Format type Format pattern Authorization
IO Field_6 Input/output Decimal 999999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = LEFT BOBBIN DIAMETER OFF DELAY;
IO Field_7 Input/output Decimal 999999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = RIGHT BOBBIN END OFF DELAY;
Button
Name Mode Authorization Text OFF Hotkey
Button_1 Text KNIFEADVANCE
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 006_KNIFE ADVANCE , Objectnumber = 0 );
Button_2 Text PREVIOUSPRODUCTION
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 007_PREVIOUS PRODUCTION ,Object number = 0 );
Button_3 Text RODDIAMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 008_DIAMETER CONTROL , Objectnumber = 0 );
Button_4 Text TRENDVIEW
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 012_TREND VIEW , Object number= 0 );
2/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:46
Screens
\SIMATIC HMI MP277\Screens019_PLC & HMI CONFIGURATIONUsing template True
Number 8
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Text Field
Name Text Foreground color Position Size
Text Field_1 Current Time of PLC 239;239;239 172, 265 270, 45
Text Field_16 PLC & HMICONFIGURATION
255;255;255 104, 1 365, 34
Text Field_2 CONFIGURATION 0;0;0 385, 157 127, 45
Button
2/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:46
Name Mode Authorization Text OFF Hotkey
Button_1 Text Perform Touch ScreenCalibration
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = CalibrateTouchScreen( );
Button_2 Text Perform PLC Time Setting
Dynamic
Name = Event; State = Enabled; Property = Press; Function list = Script_2( )SetBit( Tag = MOVE HMI TIME TO CPU );
Name = Event; State = Enabled; Property = Release; Function list = ResetBit( Tag = MOVE HMI TIME TO CPU );
Button_3 Text Perform HMI's TimeSetting
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = OpenControlPanel( );
Button_4 Text KNIFEADVANCE
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 006_KNIFE ADVANCE , Objectnumber = 0 );
Button_5 Text PREVIOUSPRODUCTION
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 007_PREVIOUS PRODUCTION ,Object number = 0 );
Button_6 Text RODDIAMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 008_DIAMETER CONTROL , Objectnumber = 0 );
Button_7 Text TRENDVIEW
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 012_TREND VIEW , Object number= 0 );
Date-Time Field
Name Mode Display system time Show date Show time
Date-Time Field_1 Output False False True
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = CPU CURRENT TIME;
2/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:48
Screens
\SIMATIC HMI MP277\Screens020_DIAGNOSIS TEMPERATUREUsing template True
Number 17
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Group
Name Position Size Layer
Group 249, 377 98, 26 0
Rectangle
Name Border color Background color Position Size
Rectangle_3 49;49;49 49;156;99 277, 377 70, 26
Rectangle_1 49;49;49 181;222;181 448, 215 60, 80
4/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:48
Name Border color Background color Position Size
Rectangle_2 49;49;49 49;156;99 448, 303 60, 40
Rectangle_4 49;49;49 181;222;181 147, 288 40, 32
Rectangle_6 49;49;49 49;156;99 356, 376 88, 26
Line
Name Color Background color Position Size
Line_1 0;0;0 255;255;255 483, 237 72, 0
Line_10 0;0;0 255;255;255 391, 257 0, 136
Line_4 0;0;0 255;255;255 8, 321 226, 0
Line_5 0;0;0 255;255;255 248, 333 0, 90
Line_6 0;0;0 255;255;255 293, 257 0, 136
Line_7 0;0;0 255;255;255 193, 393 32, 40
Line_8 0;0;0 255;255;255 170, 404 0, 48
Line_9 0;0;0 255;255;255 166, 257 0, 48
Polyline
Name Color Background color Position Size
Polyline_2 0;0;0 255;255;255 347, 293 130, 96
Polyline_5 49;49;49 255;255;255 456, 389 45, 20
Polygon
Name Background fill style Border color Position Size
Polygon_3 Solid 49;49;49 249, 377 30, 24
Circle
Name Border color Background color Position Size
Circle_1 49;49;49 49;156;99 454, 361 50, 50
Circle_2 0;0;0 255;255;255 219, 319 30, 30
Circle_3 0;0;0 255;255;255 168, 389 30, 30
Circle_4 0;0;0 255;255;255 219, 408 30, 30
Circle_5 0;0;0 198;198;198 226, 415 17, 17
4/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:48
Name Border color Background color Position Size
Circle_6 0;0;0 198;198;198 230, 329 10, 10
Circle_7 0;0;0 198;198;198 179, 399 10, 10
Text Field
Name Text Foreground color Position Size
Text Field_1 C 255;255;255 187, 233 14, 23
Text Field_10 o 255;255;255 416, 221 13, 23
Text Field_11 o 255;255;255 601, 222 13, 23
Text Field_16 TEMPERATURE STATUS 255;255;255 104, 1 365, 34
Text Field_2 C 255;255;255 304, 233 14, 23
Text Field_3 C 255;255;255 420, 233 14, 23
Text Field_4 C 255;255;255 607, 232 14, 23
Text Field_7 Diagnosis 0;0;0 130, 157 127, 45
Text Field_8 o 255;255;255 181, 223 13, 23
Text Field_9 o 255;255;255 300, 221 13, 23
IO Field
Name Mode Format type Format pattern Authorization
OBJECT_16 Output Decimal 999.9
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = TANK CHAMBER HEATER PV;
Name = Appearance; State = Enabled; Tag = TANK CHAMBER HEATER PV; Start range = 0; End range = 0; Appearance descriptions= Value : 0, Foreground Color : 0;0;0, Background Color : 255;0;0, Flashing : No; Data type = Integer; Bit position = 0;
OBJECT_18 Output Decimal 999.9
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = HOT MELT NOZZLE HEATER PV;
Name = Appearance; State = Enabled; Tag = HOT MELT NOZZLE HEATER PV; Start range = 0; End range = 0; Appearancedescriptions = Value : 0, Foreground Color : 0;0;0, Background Color : 255;0;0, Flashing : No; Data type = Integer; Bit position = 0;
4/3
SIMATIC WinCC flexible 06-03-2015 - 12:44:48
Name Mode Format type Format pattern Authorization
OBJECT_180 Output Decimal 999.9
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = ROD CHAMBER HEATER PV;
Name = Appearance; State = Enabled; Tag = ROD CHAMBER HEATER PV; Start range = 0; End range = 0; Appearance descriptions= Value : 0, Foreground Color : 0;0;0, Background Color : 255;0;0, Flashing : No; Data type = Integer; Bit position = 0;
OBJECT_36 Output Decimal 999.9
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = HOSE PIPE HEATER PV;
Name = Appearance; State = Enabled; Tag = HOSE PIPE HEATER PV; Start range = 0; End range = 0; Appearance descriptions =Value : 0, Foreground Color : 0;0;0, Background Color : 255;0;0, Flashing : No; Data type = Integer; Bit position = 0;
4/4
SIMATIC WinCC flexible 06-03-2015 - 12:44:51
Screens
\SIMATIC HMI MP277\Screens021_MAIN DRIVE STATUSUsing template True
Number 12
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Rectangle
Name Border color Background color Position Size
Rectangle_1 0;0;0 132;132;132 5, 252 544, 104
Text Field
Name Text Foreground color Position Size
Text Field_1 Description 255;255;255 12, 258 128, 45
3/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:51
Name Text Foreground color Position Size
Text Field_16 MAIN DRIVE STATUS 255;255;255 104, 1 365, 34
Text Field_2 Main Drive 255;255;255 12, 306 128, 45
Text Field_5 Hz 255;255;255 146, 257 128, 45
Text Field_6 Voltage 255;255;255 280, 256 128, 45
Text Field_7 Ampere 255;255;255 414, 256 128, 45
Text Field_9 Diagnosis 0;0;0 130, 157 127, 45
IO Field
Name Mode Format type Format pattern Authorization
IO Field_2 Output Decimal 99
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = MAIN DRIVE FREQUENCY;
IO Field_5 Output Decimal 999
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = MAIN DRIVE VOLTAGE;
IO Field_8 Output Decimal 99
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = MAIN DRIVE AMPERE;
Button
Name Mode Authorization Text OFF Hotkey
Button_1 Text KNIFEADVANCE
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 006_KNIFE ADVANCE , Objectnumber = 0 );
Button_2 Text PREVIOUSPRODUCTION
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 007_PREVIOUS PRODUCTION ,Object number = 0 );
Button_3 Text RODDIAMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 008_DIAMETER CONTROL , Objectnumber = 0 );
3/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:51
Name Mode Authorization Text OFF Hotkey
Button_4 Text TRENDVIEW
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 012_TREND VIEW , Object number= 0 );
3/3
SIMATIC WinCC flexible 06-03-2015 - 12:44:53
Screens
\SIMATIC HMI MP277\Screens022_TPU POTENTIOMETERUsing template True
Number 13
Visible layer 0;1;2;3;4;5;6;7;8;9;10;11;12;13;14;15;16;17;18;19;20;21;22;23;24;25;26;27;28;29;30;31
Infotext.
.
Rectangle
Name Border color Background color Position Size
Rectangle_1 0;0;132 255;255;255 20, 270 90, 25
Rectangle_2 0;0;132 255;255;255 117, 270 90, 25
Rectangle_3 0;0;132 255;255;255 20, 341 90, 25
Rectangle_4 0;0;132 255;255;255 118, 341 90, 25
3/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:53
Name Border color Background color Position Size
Rectangle_5 0;0;0 132;132;0 21, 219 185, 49
Text Field
Name Text Foreground color Position Size
Text Field_1 Pot. 1+2+3 V 0;0;0 26, 273 80, 18
Text Field_16 TPU POTENTIOMETER 255;255;255 104, 1 365, 34
Text Field_2 Potentio PositionRef: with Tacho 0-10V
239;239;239 28, 219 170, 46
Text Field_5 Pot. 2 V 0;0;0 136, 273 50, 18
Text Field_6 Pot. 2+3 V 0;0;0 33, 344 65, 18
Text Field_7 Pot. PZ V 0;0;0 132, 344 57, 18
IO Field
Name Mode Format type Format pattern Authorization
OBJECT_24 Output Decimal 99.99
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = POTENTIO 1+2+3 VOLTAGE STATUS;
OBJECT_25 Output Decimal 99.99
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = POTENTIO 2 VOLTAGE STATUS;
OBJECT_26 Output Decimal 99.99
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = POTENTIO 2+3 VOLTAGE STATUS;
OBJECT_27 Output Decimal 99.99
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = POTENTIO PZ VOLTAGE STATUS;
Button
Name Mode Authorization Text OFF Hotkey
Button_1 Text KNIFEADVANCE
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 006_KNIFE ADVANCE , Objectnumber = 0 );
3/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:53
Name Mode Authorization Text OFF Hotkey
Button_2 Text PREVIOUSPRODUCTION
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 007_PREVIOUS PRODUCTION ,Object number = 0 );
Button_3 Text RODDIAMETER
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 008_DIAMETER CONTROL , Objectnumber = 0 );
Button_4 Text TRENDVIEW
Dynamic
Name = Event; State = Enabled; Property = Click; Function list = ActivateScreen( Screen name = 012_TREND VIEW , Object number= 0 );
Slider
Name Minimum value Maximum value Position Size
Slider_1 0 100 231, 209 97, 208
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = POTENTIO 1+2+3 STATUS;
Name = Property/tag association; State = Disabled; Property = Maximum value;
Name = Property/tag association; State = Disabled; Property = Minimum value;
Slider_2 0 100 332, 209 97, 208
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = POTENTIO 2 STATUS;
Slider_3 0 100 433, 209 97, 208
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = POTENTIO 2+3 STATUS;
Slider_4 0 100 534, 208 97, 208
Dynamic
Name = Property/tag association; State = Enabled; Property = Process value; Tag = POTENTIO PZ PUMP STATUS;
3/3
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Tags
\SIMATIC HMI MP277\Communication\TagsTagsName Display name Connection Data type Length
1ST SHIFT PREVIOUSAVG RUNTIME
PROFIBUS DP Int 2
1ST SHIFT PREVIOUSPRODUCTION
PROFIBUS DP DInt 4
1st SHIFT PREVIOUSSTOPAGES
PROFIBUS DP Int 2
1ST SHIFT STOP TIME PROFIBUS DP Int 2
2ND SHIFT PREVIOUSAVG RUNTIME
PROFIBUS DP Int 2
2ND SHIFT PREVIOUSPRODUCTION
PROFIBUS DP DInt 4
2ND SHIFT PREVIOUSSTOPAGES
PROFIBUS DP Int 2
2ND SHIFT STOP TIME PROFIBUS DP Int 2
3RD SHIFT PREVIOUSPRODUCTION
PROFIBUS DP DInt 4
3RD SHIFT PREVIOUSSTOPAGES
PROFIBUS DP Int 2
3RD SHIFT PREVIOUSAVGRUNTIME
PROFIBUS DP Int 2
3RD SHIFT STOP TIME PROFIBUS DP Int 2
ACTUAL CUTS PROFIBUS DP DInt 4
AUXILIARY MOTORS PROFIBUS DP Bool 0
AUXILIARY MOTORSRUNNING
PROFIBUS DP Bool 0
AUXILIARY MOTORSSTOP HMI
PROFIBUS DP Bool 0
AVERAGE RUNTIME PROFIBUS DP Int 2
Bildnr <Internal tag> Long 4
BOBBIN CHANGE MOTOR PROFIBUS DP Bool 0
BRUSH MOTOR ON/OFF PROFIBUS DP Bool 0
BRUSH MOTOR RUNNING PROFIBUS DP Bool 0
COMPRESSOR RUNNING PROFIBUS DP Bool 0
CPU CURRENT TIME PROFIBUS DP Time of day 4
CURRENT PRODUCTION PROFIBUS DP DInt 4
CUT/PER KNIFE ADVANCE PROFIBUS DP DInt 4
DRIVE 1-2-3 RUNNING PROFIBUS DP Bool 0
DRY SAMPLING SET PROFIBUS DP Bool 0
FILTER KNIFE ENDALARM
PROFIBUS DP Int 2
FILTER KNIFE END STOP PROFIBUS DP Int 2
FREQUENCY DRIVE 1RPM
PROFIBUS DP Real 4
3/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Name Display name Connection Data type Length
FREQUENCY DRIVE 2RPM
PROFIBUS DP Real 4
FREQUENCY DRIVE 3RPM
PROFIBUS DP Real 4
GLUE NOZZLE ON PROFIBUS DP Bool 0
GLUE NOZZLE ON HMI PROFIBUS DP Bool 0
HEAD AND DRUM CLEAN PROFIBUS DP Bool 0
HEAD AND DRUM CLEANON
PROFIBUS DP Bool 0
hhr PROFIBUS DP Int 2
HOSE PIPE HEATER PV PROFIBUS DP Real 4
HOSE PIPE HEATER SV PROFIBUS DP Real 4
HOT MELT NOZZLEHEATER PV
PROFIBUS DP Real 4
HOT MELT NOZZLEHEATER SV
PROFIBUS DP Real 4
KDF AUTO SPEED SETPOINT
PROFIBUS DP DInt 4
KNIFE ADVANCE HMI PROFIBUS DP Bool 0
KNIFE RESET HMI PROFIBUS DP Bool 0
LEFT BOBBIN DIAMETEROFF DELAY
PROFIBUS DP Timer 2
MACHINE RUNTIMEAFTER LAST STOP
PROFIBUS DP Int 2
MAIN DRIVE AMPERE PROFIBUS DP DInt 4
MAIN DRIVE FREQUENCY PROFIBUS DP Int 2
MAIN DRIVE RPM PROFIBUS DP DInt 4
MAIN DRIVE RUNNING PROFIBUS DP Bool 0
MAIN DRIVE VOLTAGE PROFIBUS DP Int 2
Mnt PROFIBUS DP Int 2
MOVE HMI TIME TO CPU PROFIBUS DP Bool 0
NUMBER OF KNIFEADVANCE COUNTING
PROFIBUS DP Int 2
PLASTICIZER DRIVERUNNING
PROFIBUS DP Bool 0
PLASTICIZER PUMP RPM PROFIBUS DP Real 4
PLASTICIZER TANK LEVEL PROFIBUS DP Real 4
POTENTIO 1+2+3STATUS
PROFIBUS DP Int 2
POTENTIO 1+2+3VOLTAGE STATUS
PROFIBUS DP Real 4
POTENTIO 2 VOLTAGE STATUS
PROFIBUS DP Real 4
POTENTIO 2 STATUS PROFIBUS DP Int 2
POTENTIO 2+3 STATUS PROFIBUS DP Int 2
POTENTIO 2+3 VOLTAGESTATUS
PROFIBUS DP Real 4
POTENTIO PZ PUMPSTATUS
PROFIBUS DP Int 2
POTENTIO PZ VOLTAGESTATUS
PROFIBUS DP Real 4
3/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Name Display name Connection Data type Length
PRE TENSTION ROLLEROFF DELAY
PROFIBUS DP Timer 2
RESET PRESS HMI PROFIBUS DP Bool 0
RIGHT BOBBIN END OFFDELAY
PROFIBUS DP Timer 2
ROD CHAMBER HEATERPV
PROFIBUS DP Real 4
ROD CHAMBER HEATERSV
PROFIBUS DP Real 4
ROD CONTROLAUTO/MANUAL
PROFIBUS DP Bool 0
ROD CONTROL PUSHMAXIMUM HMI
PROFIBUS DP Bool 0
ROD CONTROL PUSHMINIMUM HMI
PROFIBUS DP Bool 0
ROD DIA HIGH PROFIBUS DP Bool 0
ROD DIA LOW PROFIBUS DP Bool 0
ROD DIA STABLE PROFIBUS DP Bool 0
T JET JOG BIT PROFIBUS DP Bool 0
T JET ON PROFIBUS DP Bool 0
T JET SET HMI PROFIBUS DP Bool 0
TANK CHAMBER HEATERPV
PROFIBUS DP Real 4
TANK CHAMBER HEATERSV
PROFIBUS DP Real 4
TOTAL AVG RUNTIME 3SHIFTS
PROFIBUS DP Int 2
TOTAL NO OFF STOPS PROFIBUS DP Int 2
TOTAL STOP TIME PROFIBUS DP Int 2
TRANSPORT JET OFFDELAY
PROFIBUS DP Timer 2
WARNING & ERRORMESSAGES_1
PROFIBUS DP Word 4
WARNING & ERRORMESSAGES_2
PROFIBUS DP Word 8
WARNING & ERRORMESSAGES_3
PROFIBUS DP Word 12
WARNING & ERRORMESSAGES_4
PROFIBUS DP Word 16
YELLOW MESSAGE PROFIBUS DP Bool 0
3/3
Structure
--Plc Plc
Comment Comment
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
1/1
Connections
\SIMATIC HMI MP277\Communication\ConnectionsName Communication driver Online Comment Parameters
PROFIBUS DP SIMATIC S7 300/400 On HMI device Type: SimaticBaud rate: 1500000Interface: IF1 BAddress: 4Access point: S7ONLINEOnly master on the bus:On Network Profile: DPHighest station address(HSA): 31Number of masters: 1 PLC device Address: 1Expansion slot: 2Rack: 0Cyclic operation: On
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
1/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarms
\SIMATIC HMI MP277\Alarm Management\Discrete AlarmsDiscrete AlarmsText Alarm number Alarm class Trigger tag Trigger bit number
BOBBIN NOT LOADED 1 Warnings WARNING & ERRORMESSAGES_1
0
MAIN DRIVE TRIP 2 Errors WARNING & ERRORMESSAGES_1
1
MAIN DRIVE WARNING 3 Errors WARNING & ERRORMESSAGES_1
2
MAIN DRIVE OVERVOLTAGE
4 Errors WARNING & ERRORMESSAGES_1
3
MAIN DRIVE OVERCURRENT
5 Errors WARNING & ERRORMESSAGES_1
4
MAIN DRIVE THERMALFAULT
6 Errors WARNING & ERRORMESSAGES_1
5
MACHINE AUTO MODSELECTED
7 Warnings WARNING & ERRORMESSAGES_1
6
PLASTICIZER PUMP OFF 8 Warnings WARNING & ERRORMESSAGES_1
7
AUXILIARY DRIVES OFFFM
9 Errors WARNING & ERRORMESSAGES_1
8
ROD BREAK OUT (RBO) 10 Errors WARNING & ERRORMESSAGES_1
9
MACHINE READY 11 Warnings WARNING & ERRORMESSAGES_1
10
EMERGENCY STOP FM 12 Errors WARNING & ERRORMESSAGES_1
11
HEATER OFF 13 Errors WARNING & ERRORMESSAGES_1
12
KNIFE HOOD OPEN 14 Errors WARNING & ERRORMESSAGES_1
13
MFT HOPPER FULL 15 Errors WARNING & ERRORMESSAGES_1
14
PAPER BREAK 17 Errors WARNING & ERRORMESSAGES_2
0
FM AIR PRESSURE 18 Errors WARNING & ERRORMESSAGES_2
1
OIL PRESSURE 19 Warnings WARNING & ERRORMESSAGES_2
2
ROD CUT-OFF COVER 20 Warnings WARNING & ERRORMESSAGES_2
3
INFEED DRUM JAM 21 Errors WARNING & ERRORMESSAGES_2
4
SAFETY SWITCH BACKDOOR LEFT
22 Errors WARNING & ERRORMESSAGES_2
5
KNIFE COVER LOCKINGSWITCH
23 Errors WARNING & ERRORMESSAGES_2
6
SAFETY SWITCH LEDGERCOVER
24 Errors WARNING & ERRORMESSAGES_2
7
25/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Text Alarm number Alarm class Trigger tag Trigger bit number
SAFETY SWITCH DRUMCOVER
25 Errors WARNING & ERRORMESSAGES_2
8
SAFETY SWITCH INFEEDDRUM COVER
26 Errors WARNING & ERRORMESSAGES_2
9
SAFETY SWITCH BRAKEDISC COVER
27 Errors WARNING & ERRORMESSAGES_2
10
SAFETY SWITCH BACKDOOR RIGHT
28 Errors WARNING & ERRORMESSAGES_2
11
BRAKE FLUID PRESSURE 29 Errors WARNING & ERRORMESSAGES_2
12
CUT-OFF FUSES KDF 30 Errors WARNING & ERRORMESSAGES_2
13
CIRCUIT BREAKERS KDF 31 Errors WARNING & ERRORMESSAGES_2
14
MACHINE MANUAL MODSELECTED
32 Warnings WARNING & ERRORMESSAGES_2
15
MAIN VOLTAGE GAURD 33 Errors WARNING & ERRORMESSAGES_3
0
BOBBIN ACCELERATIONDRIVE FAULT
34 Errors WARNING & ERRORMESSAGES_3
1
SAFETY SWITCHESCONTACTOR FAULT(9KA7)
35 Errors WARNING & ERRORMESSAGES_3
14
MAIN DRIVE STOP FROMTPU
36 Warnings WARNING & ERRORMESSAGES_3
3
AUXILIARY DRIVE OFFTPU
37 Warnings WARNING & ERRORMESSAGES_3
4
TPU BLOWER OFF 38 Errors WARNING & ERRORMESSAGES_3
5
PLASTICIZER COVER 39 Errors WARNING & ERRORMESSAGES_3
6
FRONT COVER UP RIGHT 40 Errors WARNING & ERRORMESSAGES_3
7
AIR PRESSURE TPU 41 Errors WARNING & ERRORMESSAGES_3
8
EMERGENCY STOP TPU 42 Errors WARNING & ERRORMESSAGES_3
9
CUT-OFF FUSES TPU 43 Errors WARNING & ERRORMESSAGES_3
10
THERMAL OVERLOAD TPU 44 Errors WARNING & ERRORMESSAGES_3
11
FRONT COVER OPEN TPU 45 Errors WARNING & ERRORMESSAGES_3
12
VOLTAGE GUARD TPU 46 Errors WARNING & ERRORMESSAGES_3
13
MAIN DRIVE STOP FROMFM
47 Warnings WARNING & ERRORMESSAGES_3
2
FREQUENCY DRIVE 1FAULT
48 Errors WARNING & ERRORMESSAGES_3
15
FREQUENCY DRIVE 2FAULT
49 Errors WARNING & ERRORMESSAGES_4
0
FREQUENCY DRIVE 3FAULT
50 Errors WARNING & ERRORMESSAGES_4
1
25/2
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Text Alarm number Alarm class Trigger tag Trigger bit number
PLASTICIZER DRIVEFAULT
51 Errors WARNING & ERRORMESSAGES_4
2
PLASTICIZER TANKEMPTY
52 Errors WARNING & ERRORMESSAGES_4
3
MFT NOT RUNNING 53 Errors WARNING & ERRORMESSAGES_4
4
KNIFE END ALARM 54 Warnings WARNING & ERRORMESSAGES_4
5
TANK CHAMBERTEMPERATURE LOW
55 Warnings WARNING & ERRORMESSAGES_4
6
HOSE PIPETEMPERATURE LOW
56 Warnings WARNING & ERRORMESSAGES_4
7
HOT MELT TEMPERATURELOW
57 Warnings WARNING & ERRORMESSAGES_4
8
ROD CHAMBERTEMPERATURE LOW
58 Warnings WARNING & ERRORMESSAGES_4
9
PLASTICIZER NOT FLOW 59 Errors WARNING & ERRORMESSAGES_4
10
MACHINE AT RUNNING 60 Warnings WARNING & ERRORMESSAGES_4
11
INFEED ARM DOWN 61 Errors WARNING & ERRORMESSAGES_4
12
TPU COVER OPEN 62 Errors WARNING & ERRORMESSAGES_4
13
EMERGENCY STOP MFT 63 Errors WARNING & ERRORMESSAGES_4
14
DELIVERY ROLLER OPEN 64 Errors WARNING & ERRORMESSAGES_4
15
Alarms
\SIMATIC HMI MP277\Alarm Management\Settings\AlarmClassesAlarm ClassesName Mode of acknowle... E-mail address Log Displayed name
Alarms Off <No log> !
Diagnosis Events Off <No log> S7
Events Off <No log>
System Off <No log> $
Alarms
\SIMATIC HMI MP277\Alarm Management\Settings\AlarmGroupsAlarm GroupsName Group number
Acknowledgement group1
1
Acknowledgement group10
10
25/3
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Name Group number
Acknowledgement group11
11
Acknowledgement group12
12
Acknowledgement group13
13
Acknowledgement group14
14
Acknowledgement group15
15
Acknowledgement group16
16
Acknowledgement group2
2
Acknowledgement group3
3
Acknowledgement group4
4
Acknowledgement group5
5
Acknowledgement group6
6
Acknowledgement group7
7
Acknowledgement group8
8
Acknowledgement group9
9
Alarms
\ProjectProjectReport Percentage of the ... System events Acknowledge group Display duration of...
True 10 HMI system alarms QGR 2
Name ALARM_S display c... SIMATIC SFM SIMOTION TO alarms SINUMERIK NC al...
PROFIBUS DP <no display class> On Off Alarm text and number
Alarms
\SIMATIC HMI MP277\Alarm Management\System eventsSystem eventsAlarm number Text
9999 Global: Unknown error%1,%2,%3,%4,%5,%6,%7,%8,%9.
10000 Print: Unknown error %1.
10001 Printing not possible: nodefault printer available.
10002 Overflow: graphics willnot be printed.
25/4
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
10003 Overflow status onprinting of graphicsended.
10004 Overflow: lines in textmode will not be printed.
10005 Overflow status onprinting of text linesended.
10006 Printer error %1: %2.
10100 No.
10101 Time
10102 Date
10103 AGR
10104 State
10105 Device
10106 Recipe
10107 Data record
10108 Tag:
10109 Type:
10110 Value:
10111 Number:
10112 Recipe does not containany data records.
10113 Recipe does not containdata record %1.
10114 There are no recipes.
10115 There are no data recordswith numbers between%1 and %2.
10116 Name:
20010 Error %1 in script <%2>in line %3.
20011 Error %1 in line %2 ofsubscript <%3> of script<%4>.
20012 Error in script <%1>during access totag/system function.
20013 Error creating scripts;error code: %1.
20014 Return value of script<%1> could not beassigned.
20015 Overflow: script <%1> isrejected.
20016 Warning: Script <%1>has been running formore than %2 seconds.
30010 Error writing a tag, errorcode: %1,%2.
30011 Invalid value %1 inparameter %2, errorcode: %3.
25/5
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
30012 Invalid value %1 inparameter %2, validrange [%3 - %4], errorcode: %5.
40010 Error in function 'linearconversion', error code:%1,%2.
40011 Error in system function'Increase' or 'Decrease'Value, error code:%1,%2.
50000 Overflow: no dataexchange with the PLC.
50001 Overflow status ended:data exchange is running.
60000 %1
60010 Error copying the file: %1to %2, error code: %3.
60011 Error copying files: sourceand destination areidentical.
70010 Error starting theapplication: %1, errorcode: %2,%3.
70011 Date/time could not beset, error code: %1,%2.
70012 Cannot exit Windows,error code: %1.
70013 Invalid input of date/time.
70014 Date/time could not beset.
70015 Date/time could not beread.
70016 Cannot select screennumber %1.
70017 Area pointer type:date/time, PLC addresserror.
70018 Password list importedsuccessfully.
70019 Password list exportedsuccessfully.
70020 Alarm reporting isactivated.
70021 Alarm reporting isdeactivated.
70022 Password list importstarted.
70023 Password list exportstarted.
70024 Error in function'IncreaseValue': Tagrange exceeded.
25/6
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
70025 Error in function'DecreaseValue': Tagrange exceeded.
70026 Cannot move back onescreen. No more screenssaved.
70027 Backup of the RAM filesystem has been started.
70028 RAM file system backupsuccessful.
70029 Backup of the RAM filesystem has failed. Errorcode: %1.
70030 Parameter error in systemfunction'ChangeConnection'. Errorcode: %1.
70031 Error in system function'ChangeConnection': Authorized only for S7PLCs.
70032 Object selection withnumber in the tab order:%1 not possible.
70033 No connection to SMTPserver or authenticationnot possible.
70034 Connection to SMTPserver established.
70036 No SMTP serverconfigured.
70037 Cannot send e-mail.
70038 Domain of recipient isunknown orauthentication notpossible.
70039 %1 : invalid e-mailaddress.
70040 %1 : invalid returnaddress in e-mail.
70041 Password list importaborted with error.
70042 Error in system function'LinearScaling': Variablevalue range exceeded.
70043 Error in system function 'InverseLinearScaling':Variable value rangeexceeded.
70044 Cannot send one or moree-mails. Check the SMTPsettings %1
70045 Could not send one ormore encrypted e-mails.
25/7
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
70046 Could not send one ormore encrypted e-mails.%1
70047 Could not send one ormore encrypted e-mails.It is not possible to set upan encrypted connection.
80001 Log %1 is %2 percent fulland must be swappedout.
80002 Error saving a line in log%1.
80003 Error copying a log to %1.
80006 ODBC(ADO) error: Cannotlog to %1.
80009 Log copied successfully.
80010 Invalid path for log %1.
80012 Logging overload - valueswill be lost.
80013 Logging overload statushas ended.
80014 Log copy in progress, newactivation ignored.
80015 %1
80016 The buffer for the log isfull. Data will be rejected.
80017 The buffer for the log isfull. Actions will berejected.
80019 All the logs have beenclosed successfully.
80020 Overload: Log copy willnot be executed.
80021 Log copy in progress.Deletion not possible atpresent.
80022 Incorrect type. Change tonext log is not possible.
80023 Source and target areidentical. Log cannot becopied.
80024 Target log not empty. Logcannot be copied.
80025 Log copy aborted by user.
80026 Log initialization ended.All logs OK.
80027 Log %1: Internal flash isnot a valid storagemedium.
80028 Log initialization started.
80029 Log initialization ended.%1 log reports error.
80030 The %1 table columns donot fit. Stopping log.
25/8
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
80031 A CSV log is corrupt.Please delete the file.
80032 Log %1 is already full.Event will not betriggered.
80033 Automatic DSN generationfailed.
80034 Initialization error, backupgeneration and resetsuccessful.
80035 Initialization error, backupgeneration and resetfailed.
80036 Logs
80037 Copy log '%1' to '%2'.
80038 Clear content of log '%1'.
80039 Start of log '%1'.
80040 Stop of log '%1'.
80041 Change over to next log'%1'.
80042 Start Audit Trail '%1'. AllGMP relevant user actionswill be logged.
80043 Stop Audit Trail '%1'. Nouser actions will belogged.
80044 Found job ('%1') offunction 'ExportLog' infilesystem, trying tocomplete job.
80045 Job ('%1') of function'ExportLog' failed, retryingto complete job in %2seconds.
80046 The destination file '%1'could not be written whileexporting the log '%2'.
80047 The log '%1' could not beread while exporting it.
80048 The log '%1' wassuccessfully exported to'%2'.
80049 The log '%1' could not berenamed to '%2' whilepreparing to export it. Thejob can not be completed.
80050 The log '%1' which shallbe exported is not closed.
80051 Could not copy the logfile. %1 includes aninvalid checksum as ofline %2.
80052 Error in case of readaccess to log file %1.
80053 Error during read accessto closed log file %1.
25/9
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
90000 Alarm
90001 Acknowledgment of alarm%1 of PLC %2.
90002 Acknowledgment of %1alarm from PLC %2; thecited messages is part ofalarm group %3.
90003 Signed:
90004 Forced:
90005 Tag
90009 System
90010 SIMATIC WinCC flexible%1 Runtime
90011 Please sign the followingaction by signing /through signature.
90012 Please confirm thefollowing intended actionwith a comment.
90013 Please confirm thefollowing intended action.
90014 <unknown object>
90015 <unknown current value>
90016 <unknown new value>
90017 Application
90018 <unknown user>
90019 Startup of %1 on device%2. Project: '%3.%4 -%5' Build %6, createdwith %7
90020 New log file during run of%1 on device %2.Project: '%3.%4 - %5'Build %6, created with%7.
90021 Stopping program run of%1 on device %2.
90022 Log files open again.
90023 Log files closed.
90024 No operator actions canbe logged due to lack ofspace on the storagemedium for log '%1'. Theoperator action willtherefore not beexecuted.
90025 Because of error state ofthe archive '%1' no useractions can be logged.Therefore the user actionwill not be executed.
25/10
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
90026 No operator actions canbe logged because the logis closed. The operatoraction will therefore notbe executed.
90027 Audit Trail
90028 The entered password isincorrect, please tryagain.
90029 The last known sequentialnumber for operatoractions differs from thenumber in the log.Continuing with a highernumber, %1.
90030 The last program run wasnot correctly exited. Thismay result in the loss ofdata.
90031 Continuing with sequentialnumber %1 for theoperator actions since thelast program run was notcorrectly exited.
90032 Running out of space onthe storage medium forlog '%1'.
90033 No more space on thestorage medium for log'%1'. As of now, no moreoperator actions requiringlogging will be executed.
90034 <unknown>
90035 Shutdown application.
90036 Shutdown application dueto a power supply failure.
90037 Close all logs.
90038 Open all logs.
90039 Forcing a user actionrequires authorization'Administration'.
90040 Audit Trail is switched offbecause of a forced useraction.
90041 A user action which has tobe logged has beentriggered without a loggedon user.
90042 Exporting a log.
90043 Some information was lostwhen trying to write tothe archive previously.
90044 A user action which has tobe confirmed wasblocked, because there isanother user actionpending.
25/11
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
90045 Acknowledgment of alarm%1.
90046 Acknowledgment of %1alarm from PLC %2; thecited messages is part ofalarm group %2.
90048 Cannot print: stop loggingthe data relevant for AuditTrail.
90049 An error occurredaccessing %1. Theprocess was canceled.
90050 Data logs
90051 Alarm logs
90052 Change the value of the'%1' tag from '%2' to'%3'.
90053 Change the value of the'%1' tag from '%2' to'%3' by entering '%4'.
90054 Change of '%1' tagrejected due to limitviolation.
90055 Change of '%1' tag failedand has been canceled.
90056 Could not perform recipeimport. %1 does notinclude a checksum.
90057 Could not import recipe.%1 includes an invalidchecksum as of line %2.
90058 Verification of checksumduring recipe import offile %1 was successful.
110000 Change to operatingmode 'offline'.
110001 Change to operatingmode 'online'.
110002 Cannot change operatingmode.
110003 PLC %1: Change tooperating mode 'offline'.
110004 PLC %1: Change tooperating mode 'online'.
110005 PLC %1: The operatingmode could not bechanged.
110006 Invalid user version.Terminating WinCCflexible Runtime.
120000 Trend no. %1 cannot bedisplayed referenced to atime axis.
120001 Trend no. %1 required todisplay a time axis.
25/12
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
120002 Trend %1: PLC addresserror.
130000 Insufficient RAM spaceavailable.
130001 Insufficient hard diskspace available.
130002 Insufficient virtualmemory available.
130003 Error: No data mediuminserted. Operation will beaborted.
130004 Error: The floppy disk iswrite-protected. Operationwill be aborted.
130005 Error: The file iswrite-protected. Operationwill be aborted.
130006 Error. File accessviolation. Operation willbe aborted.
130007 Error: Networkconnection interrupted.
130008 Error: Storage card notavailable.
130009 Error: Storage carddirectory not on a storagecard.
130010 Error: Maximum nestingdepth exceeded.
130011 SIMATIC WinCC flexibleRuntime
130012 You must exit WinCCflexible Runtime beforeyou can place thecomputer in standbymode.
130013 Storage Card not present:%1
140000 Connection established:%1, Station %2, Rack%3, Slot %4.
140001 Connection disconnected:%1, Station %2, Rack%3, Slot %4.
140003 General connection error%1.
140004 Incorrect access point ormodule configuration.
140005 Incorrect HMI deviceaddress.
140006 Invalid baud rate.
140007 Error in bus profile, errorcode: %1.
140008 Error in configuration dataon bus profile, error code:%1.
25/13
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
140009 Module for S7communication not found.
140010 No S7 communicationpeer found.
140011 Interference on bus.
140012 Communication driverscannot be loaded.
140013 PC/TS adapter does notrespond.
140014 Configured bus addressalready assigned.
140015 Incorrect baud rate orinterrupt number set.
140016 Configured interrupt is notsupported by thehardware.
140017 Configured interrupt inused by another driver.
140018 Consistency checkdisabled: %1.
140019 Reconfiguration of PLC:%1.
140020 Error in consistency checkor reconfigurationrunning: %1.
150000 Connection to interface%1 is broken.
150001 Connection to interface%1 is restored.
160000 Connection to PLC %1%2 is broken.
160001 Connection to PLC %1%2 is restored.
160010 No connection, access to%1 %2 denied.
160011 No connection, server %1%2 not registered.
160012 No connection to %1 %2,error code: %3.
160013 Warning: InProcactivation of server %1not released.
160014 OPC server projectalready started. SecondOPC server not possible!.
170000 %1 Login to S7diagnostics not possible.
170001 %1 Cannot readdiagnostics buffer: PLCnot online.
170002 %1 Cannot readdiagnostics buffer, errorcode: %2.
170003 %1 Diagnostics notpossible, error code: %2.
25/14
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
170004 %1 Diagnostics notpossible, error code:%2,%3.
170007 %1 Diagnostics notpossible, error code:%2,%3.
180000 Component %1: dataversion %2 is notsupported.
180001 Overload: Too manysimultaneous actions.
180002 Screen keyboard notavailable.
180003 unknown
190000 Tag %1: unknown error.
190001 Tag %1: error statusended.
190002 Tag %1: no processingsince PLC is not online.
190004 Tag %1: PLC addresserror.
190005 Tag %1: unknown PLCtype.
190006 Tag %1: tag type doesnot match PLC type.
190007 Tag %1: valuemodification not possible.
190008 Tag %1: threshold valueviolation. Currently [%2 -%3].
190009 Tag %1: maximum valuerange exceeded.
190010 Tag %1: overflow, valuesare lost.
190011 Tag %1: value could notbe written to the PLC.
190012 Tag %1: conversion error.
190013 Tag %1: String lengthexceeded. String has beenshortened to %2characters.
190100 Area pointer type: %1,no. %2 PLC address error.
190101 Area pointer type: %1,no. %2 internal error.
190102 Area pointer type: %1,no. %2 error statusended.
200000 %1: address for areapointer not available.
200001 %1: cannot write to areapointer.
200002 %1: Error during typeconversion.
200003 %1: error status ended.
25/15
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
200004 %1: unknown error.
200005 %1: connection faulty.
200100 No address for 'ProjectID'area pointer.
200101 Cannot write 'Project ID'area pointer.
200102 'Project ID' area pointer:Error in type conversion.
200103 'Project ID' area pointer:Error state closed.
200104 'Project ID' area pointer:Unknown error.
200105 'Project ID' area pointer:Connection error.
210000 'Job mailbox'area pointerfor connection %1: Noaddress for area pointer.
210001 'Job mailbox'area pointerfor connection %1:Cannot read/write areapointer.
210002 'Job mailbox'area pointerfor connection %1: Errorin type conversion.
210003 'Job mailbox'area pointerfor connection %1: Errorstate closed.
210004 'Job mailbox'area pointerfor connection %1:Unknown error.
210005 PLC job no: %1 invalid.
210006 PLC job no: %1terminated with error.
220000 Channel alarm: %1.
220001 Channel %1: writing todata type bool/bit notsupported.
220002 Channel %1: writing todata type byte notsupported.
220003 Channel %1: loadingerror.
220004 Channel %1: connectioninterrupted.
220005 Channel %1: connectionreestablished.
220006 Connection to PLC %1(%2) is established.
220007 Connection to PLC %1(%2) is interrupted.
220008 Interface %1 cannot beopened.
230000 Invalid entry.
230002 Entry rejected.
25/16
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
230003 Screen not available.
230005 Range exceeded. Validrange [%1 - %2].
230100 Message from Webbrowser: %1, %2.
230200 The connection %1 to %2is broken.
230201 The connection %1 to %2has been reestablished.
230202 An error has occurred.WININET.DLL reports thefollowing error: number :%1 text:%2.
230203 An error has occurred.The HTTP server reportsthe following error:number : %1 text:%2.
230300 Error in the remotedisplay.
230301 An internal error hasoccurred: %1. Noconnection possible.
230302 Cannot determine theaddress of the remoteserver. No connectionpossible.
230303 The connection to theremote server failed. Noconnection possible.
230304 The remote server isincompatible. Noconnection possible.
230305 The authentication hasfailed. Wrong password!
230306 The connection to theremote server has beeninterrupted. Connectionno longer possible.
230307 The remote server hasclosed the connection.
230308 Establishing connection toremote server %1.
230400 New
230401 Save
230402 Delete
230403 To PLC
230404 From PLC
230405 Save As
230406 Rename
230407 Display help
230408 Back
230409 Open
230500 <ENTER>
230501 <New user>
25/17
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
240000 No License Key available!%1
240001 Too many tags(Powertags) have beenconfigured!
240002 %1
240003 Authorization: Internalerror %1.
240004 Backup authorizationdefect, error code: %1.
240005 WinCC flexible Runtimehas detected a problemwith Automation LicenseManager. Please reinstallAutomation LicenseManager!
250000 PLC address error in line%1.
250001 Unknown PLC type in line%1.
250002 Tag type in line %1 doesnot match PLC type.
250003 Connection to PLC hasfailed.
260000 Invalid password or username. Logon has failed.
260001 You have insufficientauthorization.
260002 User '%1' logged on withgroup '%2'.
260003 User logged off.
260004 This user name alreadyexists. Please enteranother user name.
260005 The length of user namemust be between 1 and40 characters.
260006 Permissible length ofpassword from %1 to %2characters too small orexceeded.
260007 The logoff time must bebetween 0 and 60minutes.
260008 The file format of'PTProRun.pwl' is notcompatible. Loading of filecanceled.
260009 User cannot be deleted.
260010 PLC User
260011 PLC Password
260012 The entered passwordsare not identical.
25/18
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
260013 The entered password isinvalid because it isalready in use.
260014 Logon of user '%1' hasfailed %2 times insuccession. The user hasbeen assigned to group'%3'.
260015 User administration
260016 User '%1' hasunsuccessfully attemptedto log on %2 times insuccession.
260017 Password of user '%1' hasbeen changed.
260018 User '%1' has beencreated with group '%2'and logoff time = %3min.
260019 User '%1' has beendeleted.
260020 The group of user '%1'has been changed from'%2' to '%3'.
260021 The logoff time of user'%1' has been changedfrom %2 min. to %3 min.
260022 User '%1' has beenrenamed to '%2'.
260023 Unauthorized
260024 The password has to haveat least one number.
260025 The password has to haveat least %1 characters.
260026 The password has to haveat least one specialcharacter.
260028 SIMATIC Logon Server isnot available. Only logonby a local user is possible.
260030 SIMATIC Logon: Passwordcould not be changed.User will be logged off.
260033 SIMATIC Logon error
260034 A logon operation iscurrently active. Pleasewait.
260035 Attempting to change thepassword. Please wait.
260036 Check the licenses on theSIMATIC Logon Server. Alogon was still possible.
25/19
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
260037 Logon via the SIMATICLogon Server is notpossible because ofmissing licenses. Onlylocal logon is possible.
260038 Trying to connect withSIMATIC Logon Server.
260039 Connection to SIMATICLogon Server is possible.
260040 SIMATIC Logon: Cannotreach the %1 domain.Use local user.
260041 The entered password isincorrect.
260042 Cannot create user %1because of invalidpassword.
260043 SIMATIC Logon: Cannotlog on user '%1'.
260044 SIMATIC Logon: Cannotlog on user '%1'. The useraccount is blocked.
260045 SIMATIC Logon: User'%1' is not assignedexplicitly to any group.User will be logged off.
270000 Alarm no. %1: PLCaddress error.
270001 Overflow: Pending alarmswill be rejected.
270002 No configuration dataavailable for alarms fromthe log.
270003 The SIMOTION messageservice cannot be created.
270004 Access to persistent bufferis not possible: Alarmscannot be restored orsaved.
270005 Persistent bufferdamaged: Alarms cannotbe restored.
270006 Project modified: Alarmscannot be restored fromthe persistent buffer.
270007 Single alarms cannot berestored from thepersistent buffer.
280000 Connection to PLC %1 isestablished.
280001 Connection to PLC %1 isbroken.
280002 Program in PLC %1 hasresponded.
25/20
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
280003 Program in PLC %1 is notresponding, error code:%2.
280004 Communication error toPLC %1, error code: %2,%3.
290000 Recipe tag %1: PLCaddress error.
290001 Data record tag %1:maximum value rangeexceeded.
290002 Data record tag %1:conversion error.
290003 More than 5 data recordtags: PLC address error.
290004 More than 5 data recordtags: maximum valuerange exceeded.
290005 More than 5 data recordtags: conversion error.
290006 Limit violation. Currently[%1 - %2].
290007 Invalid data record tag%1: value rejected.
290008 Start value is used for tag%1 in recipe %2.
290010 Invalid path for recipe%1.
290011 Data record %1 notavailable.
290012 Recipe %1 not available.
290013 Data record %1 alreadyexists.
290014 File %1 does not exist.
290020 Data record %1:DAT->PLC transferstarted.
290021 Data record %1:DAT->PLC transfersuccessfully completed.
290022 Data record %1:DAT->PLC transferaborted with error.
290023 Data record %1:PLC->DAT transferstarted.
290024 Data record %1:PLC->DAT transfersuccessfully completed.
290025 Data record %1:PLC->DAT transferaborted with error.
290026 Transfer not possible.Reset data mailbox onPLC.
25/21
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
290027 Transfer not possible. Noconnection to PLC.
290030 The data record may havechanged.\nReload datarecord ?
290031 Data record %1 of recipe%2 already exists.Overwrite data record ?
290032 File %1 existsalready.\nOverwrite file ?
290033 Do you really want todelete data record %1 inrecipe %2 ?
290040 General data record error.Error code: %1.
290041 Data medium is full.
290042 Cannot edit data recordsbecause a recipe action isalready running.
290043 Save changes to datarecord %1 of recipe %2 ?
290044 Data store for this recipeis corrupt and will bedeleted.
290050 Data record exportstarted.
290051 Data record exportsuccessfully completed.
290052 Data record exportcanceled due to error.
290053 Data record importstarted.
290054 Data record importsuccessfully completed.
290055 Data record importcanceled due to error.
290056 Import/Export: Error infile %1; line %2; column%3.
290057 The tags in recipe %1 are'online'.
290058 The tags in recipe %1 are'offline'.
290059 Data record no. %1 hasbeen successfully saved.
290060 Data record memory wassuccessfully deleted.
290061 Delete data recordmemory operationaborted with error.
290062 Maximum data recordnumber range exceeded.
290063 File exists already.
290064 Deletion of data recordsstarted.
25/22
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
290065 Deletion of data recordssuccessfully completed.
290066 Do you really want todelete the recipe files ?
290067 Save As
290068 Do you really want todelete all the data recordsin recipe %1 ?
290069 Do you really want todelete all the data recordsin all recipes ?
290070 Data record %1 does notexist in file %2.
290071 Lower limit exceeded.
290072 Upper limit exceeded.
290073 Error: action aborted !
290074 %1: A data record withthe no. %2 already exists.Do you want to overwriterecord %3 with record%4 ?
290075 Data record name alreadyexists!
290076 Data record %1: Saveview to data medium.
290077 Data record %1: Saveview cancelled due toerror.
290078 Data record %1: Savetags to data medium.
290079 Data record %1: Savetags cancelled due toerror.
290080 Data record %1: Save as%2 view to data medium.
290081 Data record %1: Save as%2 view cancelled due toerror.
290082 Data record %1:Displayed data recorddeleted.
290083 Data record %1: Deletioncancelled due to error.
290084 Data record %1:Synchronization executed.
290085 Data record %1:Synchronization cancelleddue to error.
290086 Data record %1: Transferdisplayed data record toPLC.
290087 Data record %1: Transferdisplayed data record toPLC cancelled due toerror.
25/23
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
290088 Data record %1: Transferdata from PLC todisplayed data record.
290089 Data record %1: Transferdata from PLC cancelleddue to error.
290090 Data record %1:Displayed data record to%2 renamed.
290091 Data record %1:Renaming to %2cancelled due to error.
290092 Data record %1: Transferdata medium to PLC.
290093 Data record %1: Transferdata medium cancelleddue to error.
290094 Data record %1: Transferdata from PLC to datamedium.
290095 Data record %1: Transferdata from PLC cancelleddue to error.
290096 Transfer tags to PLC.
290097 Transfer tags to PLCcancelled due to error.
290098 Transfer data from PLC totags.
290099 Transfer data from PLCcancelled due to error.
290100 Data record %1: Importdata from file.
290101 Data record %1: Importdata from file cancelleddue to error.
290102 Data record %1: Loaddata medium to viewstarted.
290103 Data record %1: Loaddata medium to viewcancelled due to error.
290104 Data record %1: Loaddata medium to displayeddata record.
290105 Data record %1: Loaddata medium to displayeddata record cancelled dueto error.
290106 Set update of recipe tags'Online'.
290107 Set update of recipe tags'Offline'.
290108 Set 'Online/Offline' oftags of recipes cancelleddue to error.
25/24
SIMATIC WinCC flexible 06-03-2015 - 12:44:56
Alarm number Text
290109 Set default values ofrecipe.
290110 Set default valuescancelled due to error.
300000 Overflow: PendingAlarm_S alarms in %1 willbe rejected.
300001 PLC %1: Cannot log onfor Alarm-S service.
310000 Print job rejected. Onlyone report can be printedat a time.
310001 Printing of report %1canceled due to error.
330001 Yes
330002 No
330003 Cancel
330004 OK
330005 ?
330006 Log on
330007 User:
330008 Password:
330009 Data record no.:
330010 Data record name:
330011 Rename
330012 Group:
330013 Logoff time:
330014 Data record
330015 Name:
330016 Number:
330017 !
330024 New password:
330025 Confirmation:
330026 Password will expire in%1 day(s)
330027 Password has expired
330028 Comment
330029 Action
330030 Mandatory field
330031 Force
330032 Change password
330046
340001 Info text
340002 Info text for object
340003 Info text for screen
340004 No info text available.
340005 Long message text
600000 %1
620000 %1
25/25
SIMATIC WinCC flexible 06-03-2015 - 12:44:58
1/1
Historical data
\SIMATIC HMI MP277\Historical Data\Data LogsName Storage location Path
PRODUCTION_0 File - CSV (ASCII) \Storage Card MMC\
Historical data
\SIMATIC HMI MP277\Historical Data\Alarm LogsName Storage location Path
System_Alarms File - CSV (ASCII) \Storage Card MMC\
SIMATIC WinCC flexible 06-03-2015 - 12:44:58
1/1
Scripts
\SIMATIC HMI MP277\ScriptsName Script language Comment Header Number of lines
AVG_RUN_TIME VBScript Function AVG_RUN_TIME(RUN_TIME ,NO_OF_STOPS )
6
AVG_STOP_TIME VBScript FunctionAVG_STOP_TIME(STOP_TIME ,NO_OF_STOP )
6
DIFFERENCE VBScript Function DIFFERENCE(TARGET , PRODUCTION )
6
DisplayCurrentScreenName
VBScript SubDisplayCurrentScreenName( )
57
Script_2 VBScript Sub Script_2( ) 10
SIMATIC WinCC flexible 06-03-2015 - 12:44:58
1/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:58
1/1
Graphics lists
Signal
Range (... - ...)
Name
Selection
Comment
0Value 1Value
SIMATIC WinCC flexible 06-03-2015 - 12:44:58
1/1
User administration
\SIMATIC HMI MP277\Runtime User Administration\GroupsGroupsName Group number Authorizations Comment Password aging
Administrators 9 Administration, Operate,Monitor
Administrators havecomplete and unrestrictedaccess.
True
Users 1 Operate Users have limited access. True
User administration
\SIMATIC HMI MP277\Runtime User Administration\UsersUsersName Groups Logout time Comment
Admin Administrators 5 Administrator
User administration
\SIMATIC HMI MP277\Runtime User Administration\RuntimeSecurity SettingsRuntime Security SettingsPassword must con... Password must con... Minimum password... Initial password c... Password aging
False False 3 False False
SIMATIC WinCC flexible 06-03-2015 - 12:44:59
1/1
ProjectProject language settings
Editing language name English (United States)
Reference language name English (United States)
Language Settings
English (United States)
SIMATIC WinCC flexible 06-03-2015 - 12:44:59
1/1
SIMATIC WinCC flexible 06-03-2015 - 12:44:59
1/1
Languages and Fonts
English (United States)
Standard font Tahoma, 10pt
Fixed font families Tahoma, Courier New
Configured font families
Language switch order 0
SIMATIC WinCC flexible 06-03-2015 - 12:44:59
1/1