Adapting to people & the environmentAdapting to people & the environment

System OverviewSystem Overview

• Workspace specific

• Quality illumination

• Personal dimming control

• Occupancy sensors

• Daylight dimming

• Peak load management

• Scheduling/Reporting

Workspace specific lightingWorkspace specific lighting

• One Ergolight per standard workstation

• Positioned directly over work area

• Puts light where it is needed

Standard troffer layout: 26 fixturesStandard troffer layout: 26 fixtures

Workspace specific layout: 13 fixturesWorkspace specific layout: 13 fixtures

Application PhotoApplication Photo

Quality Direct/Indirect LightingQuality Direct/Indirect Lighting

• Center lamp distributes light

upwards, reflects off ceiling

• Provides uniform ambient

light / Softens shadows

• Eliminates cave-like room

appearance

• Outer lamps deliver extra

light on desk-top for

enhanced visibility

• Louvers control glare on

computer screens

Constant up-light in open spacesConstant up-light in open spaces

Personal Dimming Daylight Dimming Occupancy Sensing

Up-light unaffected

Occupancy and daylight sensingOccupancy and daylight sensing

• Overhead sensor location= reliable sensing

• Gradually dims outer lamps to 10% after

time delay

• Holds at 10%, before turning lamps off

• Over 30% energy savings in window-

adjacent locations

• Gradual dimming avoids

sudden changes in levels

• Maintains constant light

level at work plane

Cubicle IlluminanceCubicle Illuminance

Ceiling Height 8’x8’ 8’x10’ 10x10’

8’ 48.5 fc 45.2 fc 35.5 fc

9’ 46.8 fc 44.0 fc 33.4

10’ 44.8 fc 42.3 fc 31.3 fc

11’ 42.3 fc 40.1 fc 29.2 fc

12’ 40.4 fc 38.4 fc 25.2 fc

Workspace Dimensions

Reflectances 80/50/20. Cubicle Walls 5’ @ 50% reflectance. T8 Lamps. LLF .9

Personal Dimming ControlPersonal Dimming Control

• On-screen control panel

• Users select preferred light level

• Ceiling light stays constant

System-wide managementSystem-wide management

• FM has full control over entire Ergolight network

• Entire network can be gradually dimmed for load shedding

• Events can be scheduled on daily/weekly/monthly basis

Detailed energy reportingDetailed energy reporting

Load shedding and sensor commissioningLoad shedding and sensor commissioning

• Avoid peak demand charges with load shedding• Commission sensors with the click of a mouse

How it works: The Lighting NetworkHow it works: The Lighting Network

Where the energy savings come fromWhere the energy savings come from

Ene

rgy

Use

7 am Noon7 pm

Where the energy savings come fromWhere the energy savings come from

Ene

rgy

Use

7 am Noon7 pm

Where the energy savings come fromWhere the energy savings come from

Ene

rgy

Use

7 am Noon7 pm

Where the energy savings come fromWhere the energy savings come from

Ene

rgy

Use

7 am Noon7 pm

Where the energy savings come fromWhere the energy savings come from

Ene

rgy

Use

7 am Noon7 pm

Proven results with Ergolight ControlsProven results with Ergolight Controls

Reynolds Metals

87%

(retrofit)

Raytheon

83%

(retrofit)

BC Hydro

78%

(new construction)

Actual 3rd party resultsActual 3rd party results

• BC Hydro – Comparison Study

Weekly Power Profile Comparison – 8th floor (Ergolight) vs. 5 th floor (Reference)

0

1

2

3

4

5

6

7

8

9

Monday Tuesday Wednesday Thursday Friday Saturday Sunday Time (Hour)

Power (kW)

CPP 8 Ergolight CPP5 Open Offices

Light Right Consortium: Albany, NYLight Right Consortium: Albany, NY

• A comprehensive study on worker satisfaction and productivity

3 aesthetic mounting options3 aesthetic mounting options

Other optionsOther options

Available with T8 or T5 lamping


Recommended