Page 1: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

Whelen Engineering Company, Inc.

Adding Arges™ to Preexisting Configuration

Page 2: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

3

This Scenario will add an Arges™ to an existing configuration, setting it up with default features.

Scenario Operation

Page 3: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

4

• CenCom Core™

• Control Head

• Arges™ with Control Head or

Arges™ ProFocus™ with Control head

• 1 Virtual Input

• Priority Adjustments

Configuration Requirements

Page 4: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

5

Add all necessary hardware

Page 5: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

6

(A) Select the Arges™Control Head (B) Select Light button(C) Select Outputs (D) Select the Arges Control Head filter tab (E) Rename by clicking on Button 1 Indicator to Light, Button 2 Indicator to

Manual and Button 3 Indicator to Home*Box E are the Indicators for the Buttons on the Arges™ Control Head

Page 6: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

9

(A)Select the Light button on the Arges™ Control Head (B) Select the Arges filter tab (C) Select Press 1 (D) Select the Upper and Lower and set to Turn On

Page 7: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

10

(A) Select the Light button (B) Create another State (C) Select Press 2 and rename to ProFocus

*ProFocus Models Only

Page 8: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

11

(A) Select the Light button on the Arges™ control head (B) Select Arges tab (C) Select ProFocus™(Press 2) (D) Select Center and Upper and set to Turn On (E) Select Inner, Middle and Outer

and set to Ramp Up 250 *ProFocus Models Only

Page 9: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

12

(A)Select the Manual button (B) Select the Inputs tab (C) Select the Arges™Control Head filter tab(D) Select Press 1 (E) Set Home and Paddle Moving to Turn OFF

Page 10: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

14

(A)Select the Manual button (B) Select the Arges tab (C) Select Press 1 (D) Set Pan To Manual Mode, Tilt to Manual Mode and Set Control Master to Unlink Arges Control Head

Page 11: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

15

(A)Select the Arges™Control Head (B) Select the Home button (C) Select the Properties page(D) Select Variable Timer for switch type (E) Select 2 Sec.*

*Time can be changed

Page 12: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

16

(A)Select the Home button (B) Select the Inputs tab (C) Select the Arges™Control Head filter tab (D) Select Press 1 (E) Select Light, Manual and Paddle Moving and set

to Turn OFF

Page 13: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

18

(A)Select the Home button (B) Select the Arges™ tab (C) Select Press 1 (D) Select Pan and Set Position 180°, Tilt and Set Position -90° and Set Control Master to Unlink Arges Control Head

Page 14: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

19

(A)Select the Paddle Moving button (B) Select the Inputs tab (C) Select the Arges™Control Head filter tab (D) Select Press 1 (E) Select Manual and Home

and set to Turn OFF

Page 15: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

21

(A)Select the Paddle Moving button (B) Select the Arges™ tab (C) Select Press 1 (D) Select Set Control Master and set to Link to Arges Control Head

Page 16: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

22

(A) Select ACM Inputs (B) Select Backlight (C) Select Outputs tab (D) Select Arges™Control Head filter tab (E) Select OFF (F) Set Disable Backlight

Page 17: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

23

(A) Select ACM Inputs (B) Select Backlight (C) Select Outputs tab (D) Select Arges™Control Head filter tab (E) Select Press 1 (F) Enable Backlight and Set Backlight Intensity to 7%*

*Backlighting may be adjusted to any intensity required

Page 18: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

24

(A) Select Virtual Inputs (B) Select + to add a new Virtual Input(C) Select Properties tab (D) Rename the Virtual Input to Paddle Hold Position (E) Rename the OFF state to Hold

Page 19: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

25

(A) Select Virtual Inputs (B) Select Paddle Hole Position (C) Select Arges™ tab (D) Select OFF (Hold) (E) Select Pan and set to Hold Position and Tilt and set to Hold Position

Page 20: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

26

(A) Click on Priorities (B) Set the Priorities in order* Paddle Moving, Home, Light, Manual (C) Set Paddle Hold Position to the lowest Priority

*Priorities will change depending on User Programming. Being in this order, they can be moved

Page 21: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

27

When adding Arges™ to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding the Arges, Arges Control Head, and a Virtual Input, the configuration is now ready to be in Command of Arges.

Scenario Synopsis

Page 22: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

28

Page 23: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

29

This Document is Copyright Protected © Copyright

This document contains products that are trademarked by the Whelen Engineering Company, Inc.Reproduction is prohibited. Prices included are for reference only, refer to the Whelen Engineering Automotive Price List and its addenda for current pricing.

Whelen Engineering Company reserves the right to modify its products from those printed in this presentation. Refer to published product bulletins for specifications.

Page 24: Adding Arges to Preexisting Configuration · When adding Arges™to an existing configuration, the Arges Control Head will need to be programed to work as the default does. By adding

30


Recommended