+ All Categories
Home > Documents > ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

Date post: 13-Jan-2016
Category:
Upload: amie-turner
View: 219 times
Download: 0 times
Share this document with a friend
Popular Tags:
29
ADT490 Metering Techniques
Transcript
Page 1: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

ADT490Metering Techniques

Page 2: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

2

Introduction

‣ Alarms ALS390‣ Foundation for Troubleshooting

Page 3: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

3

Concept Review

‣ Current‣ Voltage

3

Page 4: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

4

Concept Review - Conductors

‣ Conductor resistance is American Wire Gage

4

Page 5: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

5

Concept Review - Resistance

‣ Depends Primarily on‣ Length‣ Cross-sectional area‣ Type of Material

‣ Conductors DO have Resistance

5

Page 6: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

6

Concept Review - Resistor

‣ Limit Current / Divide Voltage / Convert Energy‣ Ohms & Watts

6

Page 7: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

7

Series DC Circuits

‣ Current same / Voltage divided between Resistors

7

Page 8: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

8

Series DC Circuits - Resistance

8

Page 9: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

9

Kirchhoffs Voltage Law

9

-

Page 10: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

10

Voltage Dividers

10

Page 11: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

11

Parallel DC Circuits

‣ Voltage in each parallel branch is equal

11

Page 12: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

12

Kirchhoff’s Current Law

• For each Junction: Current in = Current out

12

Page 13: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

13

Resistance in Parallel

13

Page 14: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

14

Resistance in Parallel - Rules

‣RT always < value of smallest resistor

‣ If largest resistor many times smaller resistor‣RT approaches value of smallest resistor.

‣ If two resistors equal‣RT is half original resistance

14

Page 15: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

15

Current Dividers

15

Page 16: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

16

AC Voltage & Current

16

Page 17: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

17

AC Voltage & Current

17

Text

Page 18: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

18

Measuring with a Multimeter

18

Page 19: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

19

Using a Voltmeter

19

Page 20: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

20

Using a Voltmeter

20

Page 21: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

21

Using a Voltmeter

‣ Can use a voltmeter to check a fuse - SAFER

21

Page 22: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

22

AC Versus DC

‣ No reading‣ CHECK METER‣ Power on circuit

22

Page 23: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

23

AC Versus DC

23

Page 24: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

24

Using an Ammeter

24

Page 25: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

25

Using an Ammeter

25

Page 26: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

26

Using an Ammeter

‣ Fuse in circuit - 0 A fuse good, ? A fuse bac‣ Watch the meter raing

26

Page 27: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

27

Measuring Resistance

‣ Voltage impacts on reading - Nonsense Reading‣ Highest to Lowest - Lowest most accurate

27

Page 28: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

28

Ohmmeter Uses

‣ Check if EOL is Capacitor - Short then Charge‣ Determine device polarity

28

Page 29: ADT490 Metering Techniques. 2 Introduction ‣ Alarms ALS390 ‣ Foundation for Troubleshooting.

29

End of Presentation


Recommended