Avery Weigh-Tronix Technical Specification E1205
1
E1205advanced multi-function indicator
Description
GeneralThis specification describes theE1205 advanced multi-functionweight indicator, capable ofstand-alone operation, or ofintegration into a larger systemvia serial, FieldBus and Ethernetinterfaces.
It is a microprocessor-basedindustrial weighing system with upto 100,000 displayed incrementsfor analysing, displaying, storingand transmitting gross and netweight information.
Up to 12 load cells to beconnected with the indicator(16 with second scale).Analogue load cells or AveryWeigh-Tronix digital load cellsmay be used.
This indicator can display weightdata from two scalessimultaneously. Both scales areactive and are independentlyweighing at all times.
The E1205 can be matched toalmost any load cell system toachieve optimum accuracy,stability and repeatability.
The indicator can control itssurrounding process using fullyconfigurable I/O.Alternatively, control can beexecuted from a central systemusing an extensive range ofavailable interfaces.
Configurable FeaturesThe E1205 features a dualpurpose alpha-numeric keyboardwhich allows any of the followingfunctions to be configured duringcommissioning:
Sensitivity to weight signal
Scale capacity
Number of divisions andincrement size
Weighing Unit
Zero/back balance
Decimal marker type - point orcomma
Position of decimal marker
Calibration site gravity factor
Customer site gravity factor
Filtering using FIR orHarmonizer™ filtering systems
Ten points for linearitycorrection to ensure maximumaccuracy
Tare availability and manner ofoperation
Time and date (two or fourdigit year, battery backed)
User-definable serial outputstrings
Subtotal and grand totalinformation
Scale ID number
Alarm index operation
Recipe/filling I/Oconfiguration
2
Avery Weigh-Tronix Technical SpecificationE1205
All these characteristics arestored in non-volatile memory sothat once the ideal parameters forany given weighing system areestablished they can be retainedwith certainty for the future.
Once the scale is set up asrequired, a calibration report canbe printed showing weighingdetails (useful for the installationengineer). This allows the state ofthe system to be monitored.
Up to 300 product look ups(PLUs) are available for instantrecall of previously programmedproduct information.
Applications
Parts CountingSampling modes supported: fast;dribble; bulk
Static CheckweighingSet limits, either absolute orrelative to target. Set check-weigh bar step size.
In-Motion CheckweighingThe indicator can be used tocontrol the in-motion process asrequired.
Peak HoldRecords maximum weightmeasured. Clear button resetsmemory
WeighbridgeA broad application, offering thefollowing functions.
Three core operating modes - Re-entered first weight Stored and printed Stored first weight
Additional modes: Public weighing Axle weighing (up to 10 axles) Part loads Two platform in/out operation Simple stock control Net weight adjustment (dirt
allowance)
Database supports: Vehicles Hauliers Suppliers / Customers Browsing Outstanding vehicle report
Three Level Pack RunMonitoringSet all parameters to monitor andmanage the packing ofcomponents into boxes, andoverpacking into cartons and ontopallets. Produce all labels asrequired for tracking.
Conversion FactorEnter the factor required toconvert to custom unit
Recipe/FillingControl of complete process usingfully configurable trips.In-flight compensation and dosingvariables may be set to optimisethe process. Batching modeallows repetition of the processfor a defined quantity.
Totalising Against DedicatedProduct Look Ups (PLUs)Link weighings to PLUs forcomplete stock control.
Product List Description andTotalisingCreate customised print-outsitemising customer transactions,with grand totals.
Type Through ModeAllowing any text to be input onthe E1210 and printed out in fullon an attached printer or suitablecomputer system.
Terminal ModeGiving enhanced PC control andpower.
Remote Display ModeConnect to, or use as a remotedisplay.
Specification
Electrical
Display
TypeBlue back-lit LED.Graphics 64 x 240 pixels.Displays up to eight digits.
Decimal PointsConfigurable to any of sevenpositions
Units Displayedg, kg, lb(dec), lb oz, tons, tonnes,custom.
AnnunciatorsBalance (Gross Zero)MotionPre-set TareSemi-Automatic TareNetlb or kgPrintThree-off Trip IndicatorsMinus (below net zero)Scale 1Scale 2
Keypad
28 keys, addressing:Alpha entryNumeric entryFive soft Function keysDedicated Function KeysZero, Tare, Select, Print, Units,Totals, Scale, PLU, Standby,Escape, Enter, Clear, Text
Remote IBM PS/2 keyboard inputincluded (uses interface cable)
Load Cell Input
Analogue InputCombined minimum load cellimpedance must be greater than22Ω.
Maximum Load Cells if 350Ω(One Scale)12.
Total 350Ω Load Cells if 2ndAnalogue Input Fitted16.
Avery Weigh-Tronix Technical Specification E1205
3
Connection of InputDirect wired (Buccaneer ifsupplied stamped with scale).
ExcitationDirect current.
Voltage10 V dc.
CurrentUp to 460 mA
Remote SenseObtained from excitation, orLinked directly to reference inputconnectors at the indicator.
Input Impedance1MΩ paralleled with 2.2nF.
Signal6-20 mV maximum.
uV/ per Division0.6
ResolutionApproved 10,000 (OIML)Non- Approved 100,000
Calibration
Full digital multi-point (ten point)calibration.
Theoretical calibration possible ifparameters known.
Provides over load report.
Increment Multiplier1, 2, 5,10, 20, 50, 100, 200, 500.
AVRThree stage.
Gravity CompensationSet gravity for calibration andinstallation site.
Analogue to DigitalConvertor
Display Update Rate1, 2, 5, 10 per second.
A to D Rate120 per second.
A to D TypeDelta Sigma.
Filter
FIR & Dynamic FilteringSeven programmable Options
Dynamic FilterApplied after the FIR filter.Set the filter window size indivisions (0 - 99). A high valuewill have a large damping effecton the weight display.This significantly slows the scaleresponse to a legitimate changein weight.
Harmonizer™ Digital FilterThree programmable parameters:
Samples to Average - setsnumber of A-D conversions whichwill be averaged to give a weightreading.
IIR Filter - sets how muchdamping the Harmonizer™applies to the weight reading.Typically between 1 (low) - 8(higher).
Threshold Level - sets theminimum weight change (incalibration units) which theHarmonizer™ will not attempt tofilter out as noise.
Associated Filter Attributes
Filter Level Display Weight Noise NoiseResponse Time Sample Rate Amplitude Frequency
(seconds) (Hz)
0 0.20 8.13 Lowest Highest
1 0.35 8.13
2 0.53 8.13
3 0.96 8.13
4 1.45 8.13
5 2.09 8.13
6 2.85 8.13 Highest Lowest
Balance/Zero
SettingKeyboard push button.
OperationIgnore or recall limit exceeded.
Size of Balance RangeNormally 4%, up to 100%.
Zero IndicationWithin 4% of maximum capacity.
Under Range IndicationDisplays ‘Under Range’.
Zero TrackingConfigurable
Motion DetectionConfigurable.
4
Avery Weigh-Tronix Technical SpecificationE1205
Range/Span
Range of Adjustment0 - 100,000 divisions.
Over Range IndicationDisplays ‘Over Range’.
Tares
Three types of tares are available.Each is 100% subtractive.
Note: Interlocks between the taretypes are configurable at time ofcommissioning.
Type A - Push-Button (SemiAuto) TarePush-button operated, semi-automatic, with selectablenegative weight display.Cumulative taring is possible.
Initialisation and OperationWhen the item to tare on isapplied, press the ‘Tare’ push-button.
Indication‘Net’ annunciator is illuminated.
Type B – Keyboard (Pre-set)TareKeyboard-entered tare operatedwith negative weight display.
Initialisation & OperationEnter pre-set tare value using the0-9 keypad and press ‘Tare’ pushbutton. Multiple pre-set tares arepossible.
Indication‘Net’ annunciator is illuminatedtogether with pre-set tareannunciator (PT).
Type C - Stored TareStored tare operated withnegative weight display allowing40 separate stored tares. Will beretained when power is off.
Initialisation & OperationPress ‘pre-set tare’ push buttonfollowed by the stored number ‘1’to ‘40’ followed by ‘enter’ key.When two platforms are used, 20stored tares are available for eachplatform.
Indication‘Net’ icon is illuminated togetherwith preset tare icon (PT).
Trips
The indicator has three internaltrips as standard, and can supportup to 16 external trips via externalTrips Interface Units(see accessories).All trips (both internal andexternal) are rated at 240 V 10 A.Internal inputs are rated at TTLlevels.
Two modes have independentcontrol of the trip outputs, Alarmand Recipe. Alarm modeoperates continuously.Recipe mode is dependant on theRecipe / Filling application beingconfigured and in operation.
Alarm ModeAlarm mode has 10 independentconfigurable indexes, and cannotbe turned off. Each index can beprogrammed to operate any or alloutputs based on a given target:
None - index inactive Target Weight Status of indicator, e.g. weight
steady, checkweigh accept Input (single or specific
pattern) Output (single or specific
pattern) Time
Recipe /Filling ModeRecipe/Filling mode has 20configurable sequential steps,and is active only in Recipe/Filling mode. Each recipe(maximum 100) can beconfigured independently to theothers. Each index can beprogrammed to operate any or alloutputs based on a given target:
None – index inactive Target Weight (includes
tolerance, compensation anddosing parameters)
Status of indicator, e.g. weightsteady, checkweigh accept
Input (single or specificpattern)
Output (single or specificpattern)
Time
Other variables that can beconfigured in Recipe / Fillingmode are:
Outputs at start of step Outputs at end of step Target action (e.g. print) PLU to accumulate totals data
All configuration information isretained when power is off.
Product Look Ups(PLUs) & Totals
Information Stored per PLUSub-totals and grand totals.Application specific info storedper PLU.Memory protection of PLUs.
Maximum capacity of each PLU999,999,999.
User Definable Text Fields perPLU3, each 21 characters.
When a PLU is recalled, theindicator is automaticallyconfigured into the applicationprogramme of the PLU.All information on the PLU can bedisplayed as well as printed.
Real Time Clock
The E1205 is fitted with a realtime clock which allows the userto display and print the time anddate. This clock is battery-backedand will remain functional in theabsence of mains power.
Communications
Serial InterfaceTwo bi-directional asynchronousserial interfaces (RS232/485/422and RS232/20mA current loop) asstandard. Two additional viaoptional digital interface card.
NetworkingEthernet 10/100 TCP/IP interfaceas standard.
Fieldbus interfaces – optional –see Kits.
Avery Weigh-Tronix Technical Specification E1205
5
Electrical Power Input
Voltage110 VAC - 230 VAC nominal,50/60 Hz.
ToleranceVoltage -15 to +10%.Frequency ±10%.
Power Consumption30 VA maximum when used withfull configuration of load cells.
Cable Length2 m.
Power SupplyInternally fitted
Isolation ProtectionNone. Mains earth lead must beconnected to safety earth.
Lightning protection external.
Environment
Resistance to Dirt and MoistureProtected to IP54, in mouldedplastic enclosure.
Electrical DisturbanceImmune to electrical disturbance,including RFI as detailed inEN 45501:1992
Operating Temperature-10° C to + 40° C.
Service Temperature-10° C to + 55° C.
Storage Temperature-40° C to +70° C.
Finish
Enclosed in moulded ABS plasticcase.
Mounting Options
The indicator will desk, wall orpole mount.
Pole mounting requires optionaladapter.
Performance
Internal Resolution16,777,216.
Repeatability± 0.01% of full scale.
Span Drift Time± 50 ppm/year max.
Span Drift Temperature± 4 ppm/° C typical.
Zero Drift Time± 10 ppm ±0.1% DL/yearmaximum.
Zero Drift Temperature± 2 ppm ± 40 ppm DL/ °Cmaximum.
Warm Up TimeImmediate self test complete.
Self DiagnosticsGraphics Display
Keys
PS/2 Keyboard
A2D (x 2)
Serial Test (4)
Network interface
Ethernet port
BCD Out
Analogue Out
Pulse In
Memory
Tally Roll
Internal I/O
External I/O
Approvals
All data relating to theperformance of the machinemeets and exceeds requirementsof EN 45501:1992 EuropeanApproval (‘E’ Approval) AccuracyClass III Machines andOIML 76-1. The type approvalcertificate numbers being:
EU - UK2694South Africa -New Zealand -Australia -
Factory Options
Choice of mains power connector:UK, Euro, Australian, SouthAfrican, American.
6
Avery Weigh-Tronix Technical SpecificationE1205
Kits
The following kits are available toenable local configuration whenrequired.
1. Analogue CardProvides second analogue scaleinput and two analogue outputs4-20 mA.E11050F00000000
2. Digital CardProvides two additional bi-directional asynchronous serialinterfaces (RS232/485/422 andRS232). Also includes BCDoutput (range 1 - 100,000) andpulse input.E11050G00000000
3. Electronic Tally Roll CardSecurely stores and prints up to72,000 transactions, with detailsof scale ID, gross/tare/netweights, time, date andconsecutive number.Also acts as carrier for FieldBuscard.E11050H00000000
4. ProfiBus Interface KitEnables interfacing to ProfiBusnetwork. Includes Electronic TallyRoll card (E11050H00000000) asstandard to provide interface.E11050J00000000
5. ControlNet Interface KitEnables interfacing to ControlNetnetwork. Includes Electronic TallyRoll card (E11050H00000000) asstandard to provide interface.E11050K00000000
6. DeviceNet Interface KitEnables interfacing to DeviceNetnetwork. Includes Electronic TallyRoll card (E11050H00000000) asstandard to provide interface.E11050L00000000
7. Ethernet IP Interface KitEnables interfacing to EthernetIndustrial Protocol (IP) network.Includes Electronic Tally Roll card(E11050H00000000) as standardto provide interface.E11050M00000000
8. ModBus TCP Interface KitEnables interfacing to ModBusTCP or Ethernet (over ModbusTCP) network.Includes Electronic Tally Roll card(E11050H00000000) as standardto provide interface.E11050N00000000
9. Load Cell Connector WithInternal LoomWhen fitted, provides ability todisconnect load cell inputs fromindicator without opening the unit.70735-247
Accessories
1. External Lightning ProtectionBoxWhen fitted between the load cell/junction box, and load cell input,provides protection from lightning.E11050B00000000
2. Trips Interface Unit (TIU8)Provides eight external I/O inplace of three internal I/Oincluded as standard.Inputs rated at 12 V, outputs ratedat 240 V 10 A.
Two TIU8s may be connected tothe E1210 to provide a total of16 I/O.E11100E00000000
3. 300 mm PoleStainless steel mounting pole withtop mounting plate for indicator.E11100U00000000
4. 1000 mm PoleStainless steel mounting pole withtop mounting plate for indicatorE11100V00000000
5. Interface Leads for Platformto IndicatorSee price list.
6. Interface Leads for Indicatorto PrinterSee price list.
7. Y808Large push button unit (up to fourbuttons).
Avery Weigh-Tronix Technical Specification E1205
7
All dimensions in millimetres
DimensionsWeight
2.0 kg
Shipping Specification
Net2.0 kg
Gross4.6 kg
Measurement345 mm x 270 mm x 335 mm
Harmonised Commodity Code842390 00 0.
292 188
292330
8
Avery Weigh-Tronix Technical SpecificationE1205
E1205/4.04/Issue 1
© Avery Berkel Limited 2004. All rights reserved. This publication is issued to provide outline information only which, unless agreed by Avery Berkel Limited in writing, may not be regarded as a representation relatingto the products or services concerned. Avery Berkel Limited reserves the right to alter without notice the specification, design, price or conditions of supply of any product or service.
Your local distributor:
Produced by Avery Weigh-Tronix Publicity Department
Foundry Lane, Smethwick,West Midlands, England B66 2LP.
Tel: +44 (0)870 90 34343 Fax: +44 (0)121-224 8183
E mail: [email protected]: http://www.averyweigh-tronix.com