Traditional heating & cooling systems present considerable disadvantages, especially a high level of energy consumption
(1) Source: La Vola Companyia de Serveis Ambientals, SAL
Main disadvantages
High energy consumption• In office buildings, heating represents between 40%
and 65% of electricity consumption (1)
Noise Pollution• Internal: produced by fans• External: produced by cooling towers and air to
water machines
Increase of legionella scattering risk • In water to water systems
Poor air quality
High incidence of colds produced by air circulation
Frequent complaints from users due to overexposure to either cold or heat
Basic elements of a traditional heating & cooling system
Chiller• Either water to water or air to water: in buildings• Air to air: in households.
Cooling towers • In water to water systems.
Mixing ventilation
Refrigerated air recirculation to reduce energy consumption
3
There are other heating & cooling systems based on renewable energy, but they also show important limitations
Advantages
Efficient management of heating renewable sources
Heat supply is linked to cool demand
Low power machines are beginning to be available
Low energy consumption
Disadvantages
High cost of the system because of the machine and the considerable size of the collectors field required
High maintenance expenses
Poor architectonical integration: it requires a big surface of solar panels
Increase the risk of legionella scattering
Poor air quality, colds, complaints from users
Requires the use of chemical products to refrigerate
Solar panels with
absorption machine
Efficient management of land energy (~50% savings)
Simple and proven technology
Geothermal energy
High digging and perforation expenses: large investment return
Depends on geothecnical peculiarities
If radiant floor is used to refrigerate: Needs dehumidifiers Lacks the power required to refrigerate buildings with
moderate or high thermal load
4
AdvanClim heating & cooling system, developed by Hemera Group, solves all these problems.
Heat in winter, cooling in summer, and sanitary hot water all year round
Maximum comfort feeling for people
Noise free running
Reduce legionella and bacterial colonies risk
Keeps heating & cooling inner conditions for a long time (thermal inertia) whenever a failure of the system or an electricity supply disruption occur.
AdvanClim heating & cooling system specifications
Features
Consumption and energy costs
Use of renewable energy
Has a very low energy consumption and therefore low energy costs
Low installation cost or, if higher than the one of a traditional system, guarantees investment return in less than 4 years thanks to the energy savings obtained
Low maintenance cost
Architectonical integration
Practically invisible from outside
Takes little space of the roof
Reduce pipes volume to the minimum
Running and maintenance
Strong and long-lasting: Immune to impacts, no freezing nor overheating risks
5
This system has been installed successfully in a high number of buildings, making them highly energy efficient buildings
Companies
Institutions
ECSE Company industrial premises Olvera Business Building Juani Fashion shopping premises ...
Torcal Guest Centre (Junta de Andalucía) Fuente de Piedra pond Interpretation
Centre (Junta de Andalucía) San Telmo Educational Building (Málaga) Carcabuey Forest Protection Centre ...
Other
La Rayuela Kindergarten (Rivas, Madrid) Ranch “cortijo” at Las Valdesas Masueco Ranch Ébano building ...
6
AdvanClim system has been installed in buildings designed by prestigious and renowned architects
Carlos Hernández Pezzi
Architect and former President of the Superior Council of Colleges of Architects of Spain
Architect of Torcal Guest Centre (Málaga) , ...
... which incorporates AdvanClim system “It is the first public building of this sort of the
Junta de Andalucía that includes such developed installations in energy savings”
“It is the first public building of this sort of the Junta de Andalucía that includes such developed
installations in energy savings”
7
AdvanClim heating & cooling system bases on four main features
AdvanSol hydro-solar modules(patented)
Radiant floor
AdvanVent displacement ventilation
1
2
3
Control proprietary software of all the system
4 Water to water machine
8
Tagua = 15ºC
Impulsión 35ºC
Tsuelo = 22ºC
Tagua = 20ºC
Retorno 30ºC
Acumulador de inercia
In summer, AdvanSol hydro-solar modules cool the water that gets to a water to water heating pump, thus reducing its energy consumption
Note: The temperatures indicated are estimated ones and may suffer variations depending on the specific building
Performance
simplified sketch
9
In winter, AdvanSol modules heat the water that gets to the heating pump, reducing this way its energy consumption
Note: The temperatures indicated are estimated ones and may suffer variations depending on the specific building.
Tagua = 29ºCTsuelo = 23ºC
Tagua = 24ºC
Impulsión 7ºC
Acumulador de inercia
Retorno 12ºC
Performance
simplified sketch
10
AvdanSol hydro-solar modules not only save energy but also gives a number of benefits
Benefits
Energy savings in heating, cooling and hot water
Easy architectonical integration Height < 1 m Requires little surface (from 3% to 5% of the surface considered) *
Require no reinforcement of the surface it is settled on Weight < 25 kg/m2
Lack of noise and vibrations It doesn’t include mobile mechanical parts of any kind
Highly reliable Use of an auxiliary air to water machine to cover long periods without sun
Strong system with little maintenance requirements No freezing nor overheating risk, no mobile mechanical parts
Minimize legionella scattering risk Aerosol scattering considerably lower if compared to refrigerating towers Low risk ranked, within the same category of park fountains and irrigation systems
Refrigerating tower AdvanSol roof
Aerosol emission measures obtained
through hydro sensitive paper
* Depending on the particular building, it may be necessary to consider an additional collecting surface for winter. Such surface will depend on the target energy qualification.
11
Radiant floor provides high energy efficiency and great comfort feeling
Benefits
High energy efficiency• It works at temperatures very close to environment ones• It works only on the area occupied by people (stratification)• Reduces the thermal load produced by the radiation getting in
through windows and doors or glass walls. • Reduces the transmission thermal load getting in through
windows, doors, floor and roof. • Highly energy selective (supplies heat or cold only where
required)• Lessen thermal load oscillations and, therefore, compression
consumption.
Great comfort feeling• Thermal sensation in summer similar to the one at a cathedral
Homogeneous and silent distribution of energy
Thermal inertia• Keeps heating & cooling inner conditions whenever a failure of
the system or an electricity supply disruption occur.
12
Finally, AdvanVent displacement ventilation reduces even more energy consumption and provides higher comfort and air quality levels
Energy consumption savings Expels convective thermal loads It works at temperatures close to comfort ones Drives little air flow It works only on the occupied area Only where it is necessary Allows a higher use of free-cooling Reduces consumption on last floor Makes it unnecessary the use of fans and recirculation
filtres
Provides higher comfort level Ensures a cleaner and healthier air Reduces colds incidence
Benefits
Heating & Cooling traditional system(mixing ventilation)
AdvanClim system(AdvanVent displacement ventilation)
Air is introduced at low temperature and high speed, being mixed with the air of the rooms
Refrigerated air is recirculated to reduce energy consumption
The air introduced is only the necessary one to ventilate the building It is introduced air at a moderate temperature and at low speed Hot air is expelled, instead of mixing it with refrigerated air Air is not recirculated and no turbulence takes place
13
As a result, AdvanClim system supplies high energy savings that may reach up to 73%
Note: The figures have been taken from a traditional system based on air to water machines.
AdvanClim system energy savings compared to traditional heating & cooling systems
Energy consumption of a traditional system
Water to water Ma-chines vs. Air to water
ones
Running temperature closer to comfort
temperature
Radiant floor Displacement ventila-tion
AdvanClim system energy consumption
100
27.44
30
14
16.8
11.76
-30%
-20%
-30%
-30%
-73%
Energy savings up to 73%
14
All buildings where AdvanClim system has been installed have achieved important energy savings
Household at Osuna town
Surface of application
(m2)
Estimated consumption (MWh/year) Amortization(1)
(years)Traditional
Heating & Cooling system
450 80 27
3,5
San Telmo Educational
building (Province of Málaga)
850 160
45
2,0
Torcal Guest Centre
(Antequera city)430 100
26
2,0
Image of the installation
(1) Amortization calculations have been carried out based on old electricity fares, without considering neither subventions nor the savings derived from the absence of thermal or photovoltaic solar installations requirements.
-66%
-72%
-74%
15
Buildings incorporating AdvanClim system usually obtain “A” energy efficiency category in Heating & Cooling
Example 1: Nature Educational House (Córdoba)Example 2: ESESA Educational
Building
Heating & Cooling category
Lighting category
Overall category
A
C
A
A
B
B
A
C
A
Classrooms Main building
16
In short, AdvanClim Heating & Cooling system offers high advantages before other heating & cooling systems
Heat in winter, cooling in summer, and sanitary hot water all year round
Maximum comfort feeling for people
Noise free running
Reduce legionella and bacterial colonies risk
Keeps heating & cooling inner conditions for a long time (thermal inertia) whenever a failure of the system or an electricity supply disruption occur
Features
Consumtion & energy costs
Use of renewable energies
Has a very low energy consumption and therefore low energy costs
Low installation cost or, if higher than the one of a traditional system, guarantees investment return in less than 4 years thanks to the energy savings obtained
Low maintenance cost
Architectonical integration
Practically invisible from outside
Takes little space of the roof
Reduce pipes volumen to the minimum
Running and maintenance
Strong and long-lasting: Immune to impacts, no freezing nor overheating risks
AdvanClim system specifications
17
Telf: 902 789 472www.hemeraenergy.com
MadridCapitán Haya, 1 Planta 15Edificio Eurocentro28020 Madrid
BarcelonaLlull, 321-329Edifici Cinc08019 Barcelona
MálagaParque Tecnológico de AndalucíaAvda. Juan López Peñalver, 2129590 Campanillas - Málaga
LisboaEdificio Miraflores Office CenterAv. das Tulipas, 6 · 8ºC1495-161 Algés - Portugal