Date post: | 23-Dec-2015 |
Category: |
Documents |
Upload: | lucinda-todd |
View: | 217 times |
Download: | 0 times |
Advantys® STBHigh Density Discrete I/O Modules
AGP - English 2
Advantys® STB
Advantys STB delivers customer value in distributed I/O
SmartBuilt-in intelligence and comprehensive system software
SimpleEasy to design, install and maintain
OpenThe ideal device integration I/O solution
FlexibleModular design to perfectly meet your needs
Simply Smart products are going to amaze you !
The new Advantys STB High Density Discrete I/O modules are based on these values
AGP - English 3
Advantys® STB
Introducing 2 new Advantys STB I/O Modules Model STBDDI3725 is the new 16 point,
24 VDC Basic Digital Input Module. Model STBDDO3705 is the new 16
point, 24 VDC Basic Digital Output Module.
Accessories for the New Modules include:
Model STBXTS1180, screw type high density connector set.
Model STBXTS2180, spring type high density connector set.
Model STBXBA3000, Size 3 I/O Base
AGP - English 4
Advantys® STB
Market Values of High Density I/O
• Higher I/O Point Density per Module
• Panel Space Savings, Fewer Modules Required
• Lower System Cost per I/O Point
• Increases I/O Capacity per Island
• Uses existing Advantys STB NIMs and Accessories
• Can Be Mixed with all other Advantys Products in an Island
For systems with High I/O point requirements
AGP - English 5
Advantys® STB
Product Specifications Model STBDDI3725 Input Module
Number of Points 16 Digital Inputs4 Input groups- 4 inputs/group
Input Voltage 24 VDCType of Signal True High, Sink
IEC 1131 Type 3ON State Voltage +11 to 30 VDCOFF State Voltage –3 to 5 VDCON State Current 2.0 mA Min. @11 VDCOFF State Current 1.5 mA Max.Max. Input Voltage 35 VDC for 1.3 mSResponse Time 2 mS ON to OFF
2 mS OFF to ONConnection 2 and 3 Wire Devices
AGP - English 6
Advantys® STB
Product Features
Model STBDDI3725 Input Module
IEC Type 3 Inputs Compatible with wide range of inputdevices, both solid state and mechanical contact
Power to Field Sensors Reduces field wiring and cost
Plug and Play Functionality Modules Auto-Configure when plugged into system – no software needed
Hot Swap Capability Using Standard Type NIMs, modules will automatically start upwhen plugged into system
2 & 3 Wire Input Devices Module connector includes 4 connections for Sensor power (-) to power 3 wire devices
AGP - English 7
Advantys® STB
Product Specifications
Model STBDDO3705 Output Module
Number of Points 16 Digital Outputs 2 Output groups- 8 outputs/group
Output Voltage 19.2 to 30 VDCOutput Type True High, SourceMax. Load Current 0.5 Amps per Point
4 Amps per ModuleProtection Short Circuit ProtectionON State Voltage Drop 0.4 VDC per PointOFF State Leakage 0.4 mA @ 30 VDC per PointResponse Time 2 mS ON to OFF
2 mS OFF to ONConnection 2 Wires per Output Point
AGP - English 8
Advantys® STB
Product Features
Model STBDDO3705 Output Module
Output Protection Solid State Short Circuit Protection with Auto-recovery – no fuses needed
Output Fail State Outputs Fail Safe (OFF State) onloss of communication between module and fieldbus master
Power to Field Devices Reduces field wiring and cost
Plug and Play Functionality Modules Auto-Configure when plugged into system – no software needed
Hot Swap Capability Using Standard Type NIMs, modules will automatically start upwhen plugged into system
AGP - English 9
Advantys® STB
Product Features - Accessories Field Wiring Connector – Model STBXTS1180
Screw Terminal Type 18 Terminals per Connector
2 Connectors per Package Max. wire size, 16 AWG, 1.5mmStranded or Solid Wire
Field Wiring Connector – Model STBXTS2180
Spring Terminal Type 18 Terminals per Connector
2 Connectors per Package Max. wire size, 1.5mm (16 AWG) wireSolid Wire
I/O Base – Model STBXBA3000
Size 3 I/O Base
AGP - English 10
Advantys® STB
Put I/O precisely where you need it
Locate an extension module at the end of each island segment and the system’s network communications are delivered to the next segment.
Since only one Network Interface Module is needed for the entire configuration, system setup is simplified and costs are minimized.
With only 1 NIM, you can have up to 7 segments across 15 meters.
I/O granularity 2 , 4 ,6 or 16 channels
Increased Flexibility
AGP - English 11
Advantys® STB
I/O solutions for a wide range of applications
Advantys STB High Density I/O is ideal for distributed applications such as:
Material Handling & Conveying Belt conveyors, Special overheads, Cranes, Lifts, Electrical trucks
Packaging Blistering, Palletizing
Textile Weaving machines, Spinning machines
Food & Beverage Filling and bottling, FFS machines, Conveying, Storage systems, Packaging machines
Automotive Body shop, Painting, Assembly linesBooster with multiple pumps
Vertical boxing machine Mobile shelvingAssembly line/ conveyorVertical carousel
Where there is a high number of I/O Points
AGP - English 12
Advantys® STB
Advantys Telefast means greater simplicity wiring in your automation system equipment. Save up to 33% of wiring time!
Advantys Telefast provides greater flexibility in the selection of input and output voltage ranges and output types
Applications:
All types of industrial applications
Use Advantys Telefast ABE 7 to Simplify your wiring !
AGP - English 14
Advantys® STB
for your attentionThanks Thanks