64
COPPER, ALUMINIUM, LEAD, STEEL, PVC AND XLPE PRICE VARIATIONS FACTORS FOR ELECTRIC CABLES SANS 97 SANS 1507 SANS 1339 BS6346 SATS CSE 49E & G THE VARIATIONS IN THIS BOOKLET ARE PER 100 METRES OF CABLE FOR EACH R1,00, RISE OR FALL, PER METRIC TON IN THE PRICES OF COPPER, ALUMINIUM, LEAD, STEEL, PVC AND XLPE. ISSUED BY THE ASSOCIATION OF ELECTRIC CABLE MANUFACTURERS OF SOUTH AFRICA 2007 JOHANNESBURG CONFORMING TO SPECIFICATIONS:-
Transcript
Page 1: AECMSA Electrical Cable Price Variation Factors

COPPER, ALUMINIUM, LEAD, STEEL, PVC AND XLPE PRICE VARIATIONS FACTORSFOR ELECTRIC CABLES

SANS 97SANS 1507SANS 1339BS6346SATS CSE 49E & G

THE VARIATIONS IN THIS BOOKLET ARE PER 100 METRES OF CABLE FOR EACH R1,00, RISE OR FALL, PER METRIC TON IN

THE PRICES OF COPPER, ALUMINIUM, LEAD, STEEL, PVC AND XLPE.

ISSUED BY

THE ASSOCIATION OF ELECTRIC CABLE MANUFACTURERS OF SOUTH AFRICA

2007 JOHANNESBURG

CONFORMING TO SPECIFICATIONS:­

Page 2: AECMSA Electrical Cable Price Variation Factors

Printed 2007/04/03 Index Page 1

INDEXPage 1 1000V Low Tension General Purpose Cables to SANS 97 AFAA

Page 2 1000V Low Tension General Purpose Cables to SANS 97 AFAA

Page 3 3,3kV General Purpose Belted Cables to SANS 97 AFAA

Page 4 3,3kV General Purpose Belted Cables to SANS 97 AFAA

Page 5 6,6kV General Purpose Belted Fully impregnated Cables to SANS 97 Tables 9 & 15

Page 6 6,6kV General Purpose Belted Fully impregnated cables to SANS 97 Table 16

Page 7 6,6kV General Purpose Belted Drained Cables to SANS 97 AFAA

Page 8 6,6kV General Purpose Belted Drained Cables to SANS 97 AFAA

Page 9 11kV General Purpose Fully Impregnated Belted Cables to SANS 97 Tables 17 & 18

Page 10 11kV Screened Type Fully Impregnated General Purpose Cables to SANS 97 Tables 10 & 19.

Page 11 11kV Screened Type Fully Impregnated General Purpose Cables to SANS 97 AFAA

Page 12 11kV Drained General Purpose Belted Cables for Normal Service Conditions &

11kV Fully Impregnated Cables with Augmented Dielectric to SANS 97 AFAA

Page 13 11kV Screened Type Drained General Purpose Cable for Normal Service Conditions &

11kV Fully impregnated Cables with Augmented Dielectric to SANS 97 AFAA

Page 14 12,7/22kV General Purpose Impregnated Screened Cables to SANS 97 Tables 11 & 20

Page 15 1000V Low Tension Heavy Duty Cables to SANS 97 AFAA

Page 16 1000V Low Tension Heavy Duty Cables to SANS 97 AFAA

Page 17 3,3kV Heavy Duty (Belted) Cables to SANS 97 AFAA

Page 18 3,3kV Heavy Duty (Belted) Cables to SANS 97 Table 22.

Page 19 6,6kV Heavy Duty (Belted) Cables to SANS 97 Tables 13 & 23

Page 20 6,6kV Heavy Duty (Belted) Cables to SANS 97 Table 24

Page 21 11kV Heavy Duty (Belted) Cables to SANS 97 Tables 25 & 26

Page 22 11kV Heavy Duty Screened Cables to SANS 97 Tables 14 & 27

Page 23 11kV Heavy Duty Screened Cables to SANS 97 AFAA

Page 24 600/1000V PVC PVC SWA PVC Cables to SANS 1507

Page 25 600/1000V PVC PVC SWA PVC Cables to SANS 1507

Page 26 600/1000V PVC PVC SWA PVC Cables to SANS 1507

Page 27 600/1000V PVC PVC ECC/SWA PVC Cables to SANS 1507

Page 28 1,9/3,3kV 3 Core PVC PVC SWA PVC Cables to SANS 1507

Page 29 600/1000V Stranded AL PVC PVC SWA PVC Cables to SANS 1507

Page 30 600/1000V Solid AL PVC PVC SWA PVC Cables to SANS 1507

Page 31 600/1000V Solid AL PVC PVC SWA/ECC PVC Cables to SANS 1507

Page 32 600/1000V PVC PVCT ASA PVC or PVC PVC SWA PVC Cables to BS 6346

Page 33 600/1000V PVC PVCT ASA PVC Cables to BS 6346

Page 34 600/1000V 3 Core PVC PVC Cables with Split-Concentric Neutral &

Earth Conductors to SANS 1507

page 35 3,8/6,6kV single core type A Cable to SANS 1339

page 36 6,35/11kV single core type A cable to SANS 1339

page 37 8,7/15kV single core type A cable to SANS 1339 AFAA

page 38 12,7/22kV single core type A cable to SANS 1339

page 39 19/33kV single core type A cable to SANS 1339

Page 3: AECMSA Electrical Cable Price Variation Factors

Printed 2007/04/03 INDEX 2

INDEXpage 40 3,8/6,6kV single core type A2 cable to SANS 1339 AFAA

page 41 6,35/11kV single core type A2 cable to SANS 1339 AFAApage 42 8,7/15kV single core type A2 cable to SANS 1339 AFAA

page 43 12,7/22kV single core type A2 cable to SANS 1339 AFAA

page 44 19/33kV single core type A2 cable to SANS 1339 AFAA

page 45 3,8/6,6kV single core type B cables to SANS 1339

page 46 6,35/11kV single core type B cable to SANS 1339

page 47 8,7/15kV single core type B cable to SANS 1339 AFAA

page 48 12,7/22kV single core type B cable to SANS 1339

page 49 19/33kV single core type B cable to SANS 1339

page 50 3,8/6,6kV three core type A cable to SANS 1339

page 51 6,35/11kV three core type A cable to SANS 1339

page 52 8,7/15kV three core type A cable to SANS 1339 AFAA

page 53 12,7/22kV three core type A cable to SANS 1339

page 54 19/33kV three core type A cable to SANS 1339

Page 55 3,8/6,6kV three-core type B cable to SANS 1339

Page 56 6,35/11kV three-core type B cable to SANS 1339

Page 57 8,7/15kV three-core type B cable to SANS 1339 AFAA

Page 58 12,7/22kV three-core type B cable to SANS 1339

Page 59 19/33kV three-core type B cable to SANS 1339

Page 60 Standard Signaling Cables (outdoor) to SATS Specification No.CSE 49E

Page 61 Standard Signaling Cables (indoor) to SATS Specification No.CSE 49G

Page 4: AECMSA Electrical Cable Price Variation Factors

PAGE 1

Printed 2007/04/03

1000V LOW TENSION GENERAL PURPOSE CABLES TO SANS 97 AFAA

SINGLE CORE 2 CORERATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA DSTA SWA SERVING BEDDING AREAmm2 SERVING OVER & mm2

OVER ARMOUR SERVINGARMOUR COMBINED

6 - - - - 0.011* - 0.071 0.057 0.062 0.025 0.037 610 - - - - 0.019 - 0.071 0.056 0.060 0.025 0.036 1016 - - - - 0.031 - 0.080 0.060 0.063 0.026 0.039 1625 - - - - 0.048 0.014 0.088 0.067 0.070 0.032 0.043 2535 - - - - 0.067 0.021 0.098 0.073 0.075 0.034 0.048 3550 - - - - 0.095 0.030 0.109 0.079 0.101 0.038 0.057 5070 - - - - 0.134 0.041 0.131 0.086 0.113 0.043 0.064 7095 - - - - 0.181 0.055 0.167 0.095 0.120 0.050 0.092 95120 - - - - 0.250 0.071 0.193 0.101 0.133 0.054 0.087 120150 0.142 0.044 0.123 0.021 0.287 0.080 0.209 0.137 0.180 0.063 0.103 150185 0.175 0.053 0.143 0.023 0.354 0.109 0.235 0.147 0.193 0.067 0.112 185240 0.228 0.070 0.171 0.028 0.459 0.141 0.297 0.164 0.215 0.079 0.130 240300 0.204 0.087 0.203 0.035 0.574 0.176 0.361 0.191 0.237 0.092 0.151 300400 0.379 0.117 0.258 0.043 - 0.235 0.455 0.202 0.337 0.103 0.168 400500 0.474 0.146 0.288 0.047 - 0.294 0.510 0.220 0.366 0.112 0.192 500630 0.598 0.183 0.351 0.057 - - - - - - - 630

* Circular conductors

PAGE 1

Page 5: AECMSA Electrical Cable Price Variation Factors

PAGE 2

Printed 2007/04/03

1000V LOW TENSION GENERAL PURPOSE CABLES TO SANS 97 AFAA

3 CORE 4 CORERATED COPPER ALUMINIUM LEAD STEEL PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA DSTA SWA SERVING BEDDING DSTA SWA SERVING BEDDING AREAmm2 OVER & OVER & mm2

ARMOUR SERVING ARMOUR SERVINGCOMBINED COMBINED

6 0.017* - 0.076 0.059 0.066 0.026 0.039 0.023* - 0.084 0.064 0.069 0.027 0.042 610 0.029* - 0.087 0.066 0.072 0.032 0.043 0.030* - 0.096 0.070 0.077 0.033 0.047 1016 0.046* - 0.100 0.070 0.098 0.035 0.051 0.062* - 0.119 0.077 0.106 0.038 0.058 1625 0.072 0.022 0.100 0.072 0.084 0.035 0.051 0.095 0.030 0.122 0.082 0.109 0.041 0.059 2535 0.100 0.031 0.119 0.078 0.107 0.038 0.058 0.134 0.041 0.145 0.087 0.119 0.046 0.072 3550 0.144 0.044 0.143 0.086 0.117 0.043 0.065 0.191 0.058 0.172 0.096 0.130 0.053 0.084 5070 0.201 0.062 0.170 0.094 0.128 0.051 0.083 0.268 0.082 0.209 0.133 0.183 0.063 0.103 7095 0.273 0.084 0.203 0.129 0.180 0.060 0.101 0.364 0.112 0.257 0.149 0.202 0.071 0.119 95

120 0.344 0.106 0.235 0.140 0.194 0.066 0.110 0.459 0.140 0.297 0.160 0.215 0.079 0.130 120150 0.431 0.132 0.265 0.152 0.200 0.076 0.122 0.574 0.176 0.360 0.174 0.238 0.091 0.049 150185 0.531 0.163 0.309 0.163 0.223 0.083 0.140 0.708 0.217 0.437 0.189 0.327 0.099 0.161 185240 0.689 0.211 0.381 0.192 0.295 0.097 0.156 0.919 0.282 0.529 0.212 0.370 0.111 0.189 240300 0.861 0.264 0.450 0.201 0.351 0.105 0.179 1.148 0.353 0.630 0.234 0.440 0.122 0.209 300400 - 0.353 0.581 0.233 0.390 0.110 0.201 - 0.470 0.752 0.269 0.513 0.134 0.230 400500 - 0.441 0.679 0.253 0.481 0.127 0.217 - 0.588 0.907 0.292 0.627 0.145 0.249 500630 - - - - - - - - - - - - - - 630

* Circular conductors

PAGE 2

Page 6: AECMSA Electrical Cable Price Variation Factors

PAGE 3

Printed 2007/04/03

3,3kV GENERAL PURPOSE (BELTED) CABLES TO SANS 97 AFAA

1,9/3,3kVSINGLE CORE 3 CORE

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING AREAmm2 OVER OVER & mm2

ARMOUR ARMOUR SERVINGCOMBINED

16 - - - - 0.046* - 0.129 0.070 0.111 0.041 0.061 1625 - - - - 0.072 0.022 0.130 0.080 0.111 0.041 0.061 2535 - - - - 0.100 0.031 0.145 0.086 0.118 0.044 0.072 3550 - - - - 0.144 0.044 0.171 0.094 0.128 0.051 0.082 5070 - - - - 0.201 0.062 0.202 0.129 0.165 0.059 0.100 7095 - - - - 0.273 0.084 0.235 0.141 0.194 0.066 0.110 95

120 - - - - 0.344 0.106 0.268 0.152 0.207 0.076 0.121 120150 0.142 0.044 0.141 0.023 0.431 0.132 0.298 0.163 0.222 0.080 0.137 150185 0.175 0.053 0.150 0.027 0.531 0.163 0.364 0.174 0.239 0.091 0.149 185240 0.228 0.070 0.179 0.029 0.689 0.211 0.436 0.192 0.334 0.100 0.163 240300 0.284 0.087 0.213 0.037 0.861 0.264 0.519 0.211 0.368 0.111 0.189 300400 0.379 0.117 0.257 0.044 - 0.353 0.639 0.238 0.396 0.120 0.205 400500 0.474 0.146 0.299 0.047 - 0.441 0.740 0.258 0.489 0.130 0.222 500630 0.598 0.183 0.360 0.058 - - - - - - - 630

* Circular conductors

PAGE 3

Page 7: AECMSA Electrical Cable Price Variation Factors

PAGE 4

Printed 2007/04/03

3,3kV GENERAL PURPOSE (BELTED) CABLES TO SANS 97 AFAA

3,3/3,3kVSINGLE CORE 3 CORE

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING AREAmm2 OVER OVER & mm2

ARMOUR ARMOUR SERVINGCOMBINED

16 - - - - 0.046* - 0.132 0.081 0.115 0.043 0.064 1625 - - - - 0.072 0.022 0.131 0.083 0.116 0.043 0.064 2535 - - - - 0.100 0.031 0.151 0.090 0.123 0.045 0.077 3550 - - - - 0.144 0.044 0.180 0.097 0.133 0.053 0.085 5070 - - - - 0.201 0.062 0.211 0.134 0.183 0.063 0.103 7095 - - - - 0.273 0.084 0.246 0.146 0.200 0.067 0.113 95

120 - - - - 0.344 0.106 0.278 0.156 0.214 0.077 0.124 120150 0.142 0.044 0.149 0.026 0.431 0.132 0.319 0.167 0.239 0.088 0.143 150185 0.175 0.053 0.170 0.028 0.531 0.163 0.371 0.179 0.245 0.093 0.152 185240 0.228 0.070 0.197 0.035 0.689 0.211 0.457 0.196 0.342 0.102 0.167 240300 0.284 0.087 0.225 0.038 0.861 0.264 0.539 0.216 0.375 0.112 0.192 300400 0.379 0.117 0.278 0.045 - 0.353 0.644 0.242 0.459 0.123 0.209 400500 0.474 0.146 0.303 0.049 - 0.441 0.750 0.262 0.491 0.131 0.225 500630 0.598 0.183 0.360 0.059 - - - - - - - 630

* Circular conductors

PAGE 4

Page 8: AECMSA Electrical Cable Price Variation Factors

PAGE 5

Printed 2007/04/03

6,6kV GENERAL PURPOSE (BELTED) FULLY IMPREGNATED CABLES TO SANS 97 TABLES 9 & 15

3,8/6,6kV EARTHEDSINGLE CORE 3 CORE

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING AREAmm2 OVER OVER & mm2

ARMOUR ARMOUR SERVINGCOMBINED

16 - - - - 0.066* - 0.151 0.086 0.118 0.045 0.077 1625 - - - - 0.072 0.022 0.150 0.088 0.120 0.044 0.076 2535 - - - - 0.100 0.031 0.172 0.094 0.128 0.051 0.083 3550 - - - - 0.144 0.044 0.194 0.101 0.137 0.054 0.085 5070 - - - - 0.201 0.062 0.233 0.139 0.192 0.065 0.107 7095 - - - - 0.273 0.084 0.261 0.152 0.208 0.076 0.121 95

120 - - - - 0.344 0.106 0.310 0.162 0.222 0.080 0.131 120150 0.142 0.044 0.151 0.027 0.431 0.132 0.361 0.173 0.237 0.091 0.148 150185 0.175 0.053 0.172 0.029 0.531 0.163 0.382 0.185 0.296 0.097 0.158 185240 0.228 0.070 0.201 0.035 0.689 0.211 0.464 0.202 0.350 0.105 0.177 240300 0.284 0.087 0.234 0.039 0.861 0.264 0.554 0.221 0.384 0.116 0.196 300400 0.379 0.117 0.267 0.046 - 0.353 0.663 0.248 0.472 0.125 0.213 400500 0.474 0.146 0.310 0.054 - 0.441 0.781 0.269 0.508 0.134 0.227 500630 0.598 0.183 0.371 0.059 - - - - - - - 630

* Circular conductors

PAGE 5

Page 9: AECMSA Electrical Cable Price Variation Factors

PAGE 6

Printed 2007/04/03

6,6kV GENERAL PURPOSE (BELTED) FULLY IMPREGNATED CABLES TO SANS 97 TABLE 16

6,6/6,6kV UNEARTHEDSINGLE CORE 3 CORE TABLE 16

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING AREAmm2 OVER OVER & mm2

ARMOUR ARMOUR SERVINGCOMBINED

16 - - - - 0.046* - 0.172 0.094 0.125 0.051 0.083 1625 - - - - 0.072 0.022 0.172 0.095 0.129 0.051 0.082 2535 - - - - 0.100 0.031 0.182 0.099 0.135 0.054 0.086 3550 - - - - 0.144 0.044 0.213 0.138 0.186 0.063 0.103 5070 - - - - 0.201 0.062 0.254 0.147 0.201 0.070 0.118 7095 - - - - 0.273 0.084 0.293 0.158 0.217 0.078 0.126 95

120 - - - - 0.344 0.106 0.317 0.168 0.230 0.088 0.144 120150 0.142 0.044 0.171 0.028 0.431 0.132 0.373 0.179 0.245 0.093 0.153 150185 0.175 0.053 0.194 0.030 0.531 0.163 0.445 0.192 0.334 0.100 0.163 185240 0.228 0.070 0.224 0.037 0.689 0.211 0.488 0.209 0.375 0.109 0.186 240300 0.284 0.087 0.252 0.044 0.861 0.264 0.570 0.227 0.395 0.118 0.202 300400 0.379 0.117 0.299 0.048 - 0.353 0.684 0.253 0.479 0.128 0.217 400500 0.474 0.146 0.348 0.057 - 0.441 0.790 0.275 0.519 0.137 0.234 500630 0.598 0.183 0.380 0.066 - - - - - - - 630

* Circular conductors

PAGE 6

Page 10: AECMSA Electrical Cable Price Variation Factors

PAGE 7

Printed 2007/04/03

6,6kV GENERAL PURPOSE (BELTED) DRAINED CABLES TO SANS 97 AFAA

3,8/6,6kV EARTHEDSINGLE CORE 3 CORE

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING AREAmm2 OVER OVER & mm2

ARMOUR ARMOUR SERVINGCOMBINED

16 - - - - 0.046* 0.177 0.093 0.127 0.053 0.084 1625 - - - - 0.072 0.022 0.172 0.095 0.131 0.051 0.083 2535 - - - - 0.100 0.031 0.201 0.120 0.164 0.056 0.097 3550 - - - - 0.144 0.044 0.225 0.138 0.194 0.064 0.106 5070 - - - - 0.201 0.062 0.267 0.152 0.204 0.071 0.119 7095 - - - - 0.273 0.084 0.297 0.163 0.220 0.079 0.130 95

120 - - - - 0.344 0.106 0.361 0.174 0.237 0.090 0.147 120150 0.142 0.044 0.168 0.028 0.431 0.132 0.383 0.183 0.295 0.096 0.155 150185 0.175 0.053 0.181 0.030 0.531 0.163 0.445 0.197 0.339 0.101 0.165 185240 0.228 0.070 0.209 0.036 0.689 0.211 0.532 0.215 0.371 0.111 0.189 240300 0.284 0.087 0.257 0.043 0.861 0.264 0.613 0.234 0.399 0.120 0.205 300400 0.379 0.117 0.287 0.047 - 0.353 0.738 0.262 0.487 0.130 0.222 400500 0.474 0.146 0.353 0.056 - 0.441 0.852 0.282 0.597 0.139 0.237 500630 0.598 0.183 0.382 0.065 - - - - - - - 630

*Circular conductors

PAGE 7

Page 11: AECMSA Electrical Cable Price Variation Factors

PAGE 8

Printed 2007/04/03

6,6kV GENERAL PURPOSE (BELTED) DRAINED CABLES TO SANS 97 AFAA.

6,6/6,6kV UNEARTHEDSINGLE CORE 3 CORE

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING AREAmm2 OVER OVER & mm2

ARMOUR ARMOUR SERVINGCOMBINED

16 - - - - 0.046* - 0.202 0.130 0.181 0.086 0.101 1625 - - - - 0.072 0.022 0.204 0.130 0.166 0.085 0.100 2535 - - - - 0.100 0.031 0.224 0.137 0.189 0.091 0.105 3550 - - - - 0.144 0.044 0.256 0.148 0.196 0.100 0.118 5070 - - - - 0.201 0.062 0.297 0.159 0.217 0.110 0.126 7095 - - - - 0.273 0.084 0.316 0.170 0.233 0.126 0.145 95

120 - - - - 0.344 0.106 0.377 0.181 0.293 0.133 0.154 120150 0.142 0.044 0.194 0.030 0.431 0.132 0.445 0.193 0.334 0.141 0.164 150185 0.175 0.053 0.203 0.036 0.531 0.532 0.477 0.203 0.354 0.151 0.179 185240 0.228 0.070 0.234 0.039 0.689 0.211 0.560 0.221 0.384 0.165 0.195 240300 0.284 0.087 0.278 0.046 0.861 0.264 0.642 0.240 0.474 0.179 0.212 300400 0.379 0.117 0.306 0.055 - 0.353 0.772 0.267 0.505 0.191 0.228 400500 0.474 0.146 0.370 0.059 - 0.441 0.886 0.287 0.612 0.205 0.245 500630 0.598 0.183 0.445 0.069 - - - - - - - 630

*Circular conductors

PAGE 8

Page 12: AECMSA Electrical Cable Price Variation Factors

PAGE 9

Printed 2007/04/03

11kV GENERAL PURPOSE FULLY IMPREGNATED BELTED CABLES TO SANS 97 TABLES 17 & 18

6,35/11kV EARTHED 11/11kV UNEARTHED3 CORE TABLE 17 3 CORE TABLE 18

RATED COPPER ALUMINIUM LEAD STEEL PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA DSTA SWA SERVING BEDDING DSTA SWA SERVING BEDDING AREAmm2 OVER & OVER & mm2

ARMOUR SERVING ARMOUR SERVINGCOMBINED COMBINED

16 0.046* - 0.183 0.101 0.138 0.054 0.087 0.046* - 0.222 0.140 0.189 0.065 0.106 1625 0.072 0.022 0.183 0.090 0.136 0.054 0.006 0.072 0.022 0.221 0.144 0.189 0.064 0.105 2535 0.100 0.031 0.205 0.134 0.183 0.060 0.102 0.100 0.031 0.256 0.147 0.201 0.067 0.112 3550 0.144 0.044 0.245 0.145 0.198 0.066 0.110 0.144 0.044 0.276 0.156 0.214 0.077 0.186 5070 0.201 0.062 0.277 0.155 0.212 0.076 0.122 0.201 0.062 0.319 0.168 0.229 0.084 0.142 7095 0.273 0.084 0.308 0.167 0.239 0.084 0.141 0.273 0.084 0.372 0.180 0.245 0.092 0.151 95

120 0.344 0.106 0.366 0.178 0.245 0.092 0.150 0.344 0.106 0.404 0.190 0.330 0.098 0.160 120150 0.431 0.132 0.393 0.188 0.329 0.098 0.159 0.431 0.132 0.461 0.201 0.350 0.104 0.175 150185 0.531 0.163 0.465 0.201 0.349 0.103 0.168 0.531 0.163 0.540 0.215 0.372 0.111 0.188 185240 0.689 0.211 0.541 0.218 0.378 0.112 0.192 0.689 0.211 0.583 0.230 0.398 0.118 0.202 240300 0.861 0.264 0.633 0.237 0.464 0.123 0.208 0.861 0.264 0.672 0.248 0.484 0.127 0.217 300400 - 0.353 0.750 0.264 0.497 0.131 0.225 - 0.353 0.781 0.275 0.517 0.134 0.231 400500 - 0.441 0.860 0.289 0.612 0.140 0.240 - 0.441 0.907 0.296 0.632 0.145 0.250 500

*Circular conductors

PAGE 9

Page 13: AECMSA Electrical Cable Price Variation Factors

PAGE 10

Printed 2007/04/03

11kV SCREENED TYPE FULLY IMPREGNATED GENERAL PURPOSE CABLES TO SANS 97 TABLES 10 & 19.

6,35/11kV EARTHEDSINGLE CORE TABLE 10 3 CORE TABLE 19

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING AREAmm2 OVER OVER & mm2

ARMOUR ARMOUR SERVINGCOMBINED

16 - - - - 0.046* - 0.204 0.132 0.178 0.059 0.100 1625 - - - - 0.072 0.022 0.202 0.141 0.188 0.056 0.097 2535 - - - - 0.100 0.031 0.214 0.147 0.196 0.063 0.104 3550 - - - - 0.144 0.044 0.245 0.159 0.207 0.067 0.113 5070 - - - - 0.201 0.062 0.298 0.164 0.215 0.078 0.125 7095 - - - - 0.273 0.084 0.314 0.175 0.231 0.088 0.144 95

120 - - - - 0.344 0.106 0.382 0.193 0.251 0.093 0.152 120150 0.142 0.044 0.177 0.029 0.431 0.132 0.434 0.198 0.334 0.100 0.163 150185 0.175 0.053 0.202 0.035 0.531 0.163 0.464 0.209 0.351 0.105 0.177 185240 0.228 0.070 0.221 0.038 0.689 0.211 0.523 0.230 0.386 0.114 0.194 240300 0.284 0.087 0.267 0.045 0.861 0.264 0.645 0.256 0.467 0.124 0.211 300400 0.379 0.117 0.309 0.049 - 0.353 0.770 0.269 0.544 0.132 0.227 400500 0.474 0.146 0.362 0.058 - 0.441 0.887 0.289 0.617 0.142 0.244 500630 0.598 0.183 0.434 0.068 - - - - - - - 630

*Circular conductors

PAGE 10

Page 14: AECMSA Electrical Cable Price Variation Factors

PAGE 11

Printed 2007/04/03

11kV SCREENED TYPE FULLY IMPREGNATED GENERAL PURPOSE CABLES TO SANS 97 AFAA.

11/11kV UNEARTHEDSINGLE CORE 3 CORE

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING AREAmm2 OVER OVER & mm2

ARMOUR ARMOUR SERVINGCOMBINED

16 - - - - 0.046* - 0.276 0.161 0.211 0.076 0.122 1625 - - - - 0.072 0.022 0.275 0.159 0.217 0.075 0.121 2535 - - - - 0.100 0.031 0.309 0.169 0.228 0.078 0.126 3550 - - - - 0.144 0.044 0.326 0.180 0.230 0.088 0.144 5070 - - - - 0.201 0.062 0.382 0.191 0.249 0.093 0.153 7095 - - - - 0.273 0.084 0.444 0.199 0.334 0.100 0.164 95

120 - - - - 0.344 0.106 0.477 0.207 0.354 0.105 0.177 120150 0.142 0.044 0.224 0.037 0.431 0.132 0.546 0.221 0.376 0.112 0.191 150185 0.175 0.053 0.235 0.039 0.531 0.163 0.580 0.236 0.390 0.117 0.200 185240 0.228 0.070 0.268 0.045 0.689 0.211 0.673 0.246 0.477 0.209 0.213 240300 0.284 0.087 0.308 0.054 0.861 0.264 0.771 0.273 0.517 0.134 0.230 300400 0.379 0.117 0.359 0.058 - 0.353 0.897 0.292 0.627 0.143 0.246 400500 0.474 0.146 0.419 0.067 - 0.441 1.021 0.313 0.668 0.152 0.261 500630 0.598 0.183 0.453 0.078 - - - - - - - 630

*Circular conductors

PAGE 11

Page 15: AECMSA Electrical Cable Price Variation Factors

PAGE 12

Printed 2007/04/03

6,35/11kV EARTHED 11/11kV UNEARTHED3 CORE 3 CORE

RATED COPPER ALUMINIUM LEAD STEEL PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA DSTA SWA SERVING BEDDING DSTA SWA SERVING BEDDING AREAmm2 OVER & OVER & mm2

ARMOUR SERVING ARMOUR SERVINGCOMBINED COMBINED

16 0.046* - 0.233 0.137 0.197 0.066 0.111 0.046* - 0.308 0.167 0.219 0.079 0.129 1625 0.072 0.022 0.232 0.155 0.200 0.066 0.110 0.072 0.022 0.305 0.172 0.228 0.078 0.128 2535 0.100 0.031 0.267 0.156 0.213 0.071 0.120 0.100 0.031 0.319 0.171 0.231 0.080 0.131 3550 0.144 0.144 0.309 0.172 0.228 0.078 0.129 0.144 0.044 0.371 0.191 0.245 0.092 0.150 5070 0.201 0.062 0.360 0.178 0.231 0.090 0.146 0.201 0.062 0.397 0.195 0.325 0.098 0.160 7095 0.273 0.084 0.381 0.190 0.292 0.096 0.155 0.273 0.084 0.466 0.208 0.351 0.104 0.176 95

120 0.344 0.106 0.452 0.201 0.337 0.101 0.165 0.344 0.106 0.539 0.220 0.367 0.110 0.188 120150 0.431 0.132 0.475 0.206 0.357 0.106 0.180 0.431 0.132 0.558 0.232 0.385 0.116 0.196 150185 0.531 0.163 0.549 0.222 0.379 0.112 0.192 0.531 0.163 0.645 0.243 0.463 0.122 0.207 185240 0.689 0.211 0.637 0.247 0.460 0.122 0.206 0.689 0.211 0.749 0.260 0.496 0.129 0.221 240300 0.861 0.264 0.739 0.268 0.494 0.130 0.223 0.861 0.264 0.841 0.280 0.529 0.138 0.242 300400 - 0.353 0.864 0.287 0.602 0.139 0.238 - 0.353 0.979 0.300 0.638 0.147 0.252 400500 - 0.441 0.978 0.306 0.648 0.148 0.255 - 0.441 1.112 0.321 0.679 0.155 0.269 500

*Circular conductors

PAGE 12

11kV DRAINED GENERAL PURPOSE (BELTED) CABLES FOR NORMAL SERVICE CONDITIONS & 11kV FULLY IMPREGNATED-CABLES WITH AUGMENTED DIELECTRIC TO SANS 97 AFAA

Page 16: AECMSA Electrical Cable Price Variation Factors

PAGE 13

Printed 2007/04/03

6,35/11kV 11/11kVSINGLE CORE 3 CORE SINGLE CORE

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC COPPER ALUMINIUM LEAD PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING SERVING AREAmm2 OVER OVER & OVER mm2

ARMOUR ARMOUR SERVING ARMOURCOMBINED

16 - - - - 0.046* - 0.232 0.146 0.199 0.066 0.111 - - - - 1625 - - - - 0.072 0.022 0.231 0.155 0.199 0.065 0.108 - - - - 2535 - - - - 0.100 0.031 0.267 0.156 0.211 0.071 0.119 - - - - 3550 - - - - 0.144 0.044 0.308 0.166 0.228 0.078 0.126 - - - - 5070 - - - - 0.201 0.062 0.361 0.179 0.246 0.089 0.146 - - - - 7095 - - - - 0.273 0.084 0.386 0.191 0.319 0.096 0.155 - - - - 95120 - - - - 0.344 0.106 0.454 0.198 0.327 0.101 0.164 - - - - 120150 0.142 0.044 0.192 0.035 0.431 0.132 0.477 0.212 0.357 0.106 0.179 0.142 0.044 0.255 0.043 150185 0.175 0.053 0.224 0.037 0.531 0.163 0.549 0.220 0.379 0.112 0.192 0.175 0.053 0.267 0.045 185240 0.228 0.070 0.256 0.043 0.689 0.211 0.634 0.244 0.460 0.122 0.206 0.228 0.070 0.308 0.048 240300 0.284 0.087 0.293 0.047 0.861 0.264 0.734 0.263 0.497 0.130 0.222 0.284 0.087 0.359 0.058 300400 0.379 0.117 0.320 0.055 - 0.353 0.867 0.283 0.607 0.139 0.238 - - - - 400500 0.474 0.146 0.371 0.060 - 0.441 1.001 0.276 0.648 0.148 0.255 0.474 0.146 0.456 0.070 500630 0.598 0.183 0.442 0.069 - - - - - - - 0.598 0.183 0.536 0.083 630

* Circular conductors

PAGE 13

11 kV SCREENED TYPE DRAINED GENERAL PURPOSE CABLE FOR NORMAL SERVICE CONDITIONS & 11kV FULLY IMPREGNATED CABLES WITH AUGMENTED DIELECTRIC TO SANS 97 AFAA

Page 17: AECMSA Electrical Cable Price Variation Factors

PAGE 14

Printed 2007/04/03

12,7/22kV GENERAL PURPOSE IMPREGNATED SCREENED CABLES TO SANS 97 TABLES 11 & 20

12,7/22kVSINGLE CORE TABLE 11 3 CORE TABLE 20

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING AREAmm2 OVER OVER & mm2

ARMOUR ARMOUR SERVINGCOMBINED

25 - - - - 0.072* 0.022* 0.400 0.194 0.322 0.096 0.167 2535 - - - - 0.100* 0.031* 0.459 0.205 0.341 0.099 0.175 3550 - - - - 0.144 0.044 0.413 0.204 0.341 0.101 0.172 5070 - - - - 0.201 0.062 0.481 0.217 0.364 0.107 0.189 7095 - - - - 0.273 0.084 0.553 0.233 0.390 0.114 0.198 95

120 - - - - 0.344 0.106 0.584 0.243 0.399 0.120 0.208 120150 0.162 0.064 0.232 0.040 0.431 0.132 0.662 0.249 0.470 0.125 0.218 150185 0.175 0.053 0.261 0.044 0.531 0.163 0.694 0.261 0.495 0.126 0.229 185240 0.228 0.070 0.296 0.047 0.689 0.211 0.800 0.274 0.526 0.131 0.246 240300 0.284 0.087 0.361 0.057 0.861 0.264 0.907 0.293 0.622 0.143 0.261 300400 0.379 0.117 0.379 0.066 1.148 0.353 1.045 0.313 0.668 - - 400500 0.474 0.146 0.445 0.074 1.436 0.441 1.171 0.361 0.710 - - 500630 0.598 0.183 0.485 0.085 - - - - - - - 630

*Circular conductors

PAGE 14

Page 18: AECMSA Electrical Cable Price Variation Factors

PAGE 15

Printed 2007/04/03

1000V LOW TENSION HEAVY DUTY CABLES TO SANS 97 AFAA

SINGLE CORE 2 CORERATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING AREAmm2 OVER OVER & mm2

ARMOUR ARMOUR SERVINGCOMBINED

10 - - - - 0.019* - 0.097 0.064 0.081 0.027 0.039 1016 - - - - 0.031* - 0.109 0.067 0.087 0.032 0.044 1625 - - - - 0.048 0.014 0.124 0.073 0.095 0.034 0.048 2535 - - - - 0.067 0.021 0.150 0.098 0.103 0.040 0.063 3550 - - - - 0.095 0.030 0.168 0.107 0.111 0.042 0.070 5070 - - - - 0.134 0.041 0.196 0.116 0.152 0.153 0.084 7095 - - - - 0.181 0.055 0.245 0.127 0.168 0.055 0.093 95

120 - - - - 0.230 0.071 0.256 0.135 0.176 0.062 0.102 120150 0.142 0.044 0.187 0.023 0.287 0.088 0.316 0.148 0.231 0.070 0.122 150185 0.175 0.053 0.202 0.027 0.354 0.109 0.338 0.157 0.263 0.077 0.128 185240 0.228 0.070 0.234 0.030 0.459 0.141 0.414 0.174 0.292 0.090 0.146 240300 0.284 0.087 0.298 0.037 0.574 0.176 0.488 0.191 0.320 0.098 0.165 300400 0.379 0.117 0.330 0.045 - 0.235 0.581 0.208 0.347 0.106 0.180 400500 0.474 0.146 0.375 0.055 - 0.294 0.688 0.231 0.386 0.117 0.200 500630 0.598 0.183 0.465 0.059 - - - - - - - 630

*Circular conductors

PAGE 15

Page 19: AECMSA Electrical Cable Price Variation Factors

PAGE 16

Printed 2007/04/03

1000V LOW TENSION HEAVY DUTY CABLES TO SANS 97 AFAA

3 CORE 4 CORERATED COPPER ALUMINIUM LEAD STEEL PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA DSTA SWA SERVING BEDDING DSTA SWA SERVING BEDDING AREAmm2 OVER & OVER & mm2

ARMOUR SERVING ARMOUR SERVINGCOMBINED COMBINED

10 0.029* - 0.129 0.074 0.094 0.037 0.048 0.038* - 0.139 0.098 0.099 0.036 0.062 1016 0.046* - 0.143 0.103 0.104 0.039 0.064 0.062* - 0.167 0.109 0.114 0.040 0.066 1625 0.072 0.022 0.153 0.100 0.107 0.040 0.064 0.095 0.030 0.183 0.111 0.114 0.043 0.074 2535 0.100 0.031 0.179 0.109 0.115 0.043 0.071 0.134 0.041 0.202 0.119 0.160 0.051 0.085 3550 0.144 0.044 0.198 0.118 0.157 0.051 0.085 0.191 0.058 0.245 0.132 0.174 0.056 0.097 5070 0.201 0.062 0.245 0.129 0.173 0.056 0.095 0.268 0.082 0.302 0.141 0.194 0.066 0.110 7095 0.273 0.084 0.275 0.141 0.188 0.064 0.106 0.364 0.112 0.340 0.158 0.269 0.078 0.129 95

120 0.344 0.106 0.318 0.152 0.241 0.072 0.124 0.459 0.140 0.402 0.172 0.289 0.089 0.145 120150 0.431 0.132 0.383 0.166 0.272 0.083 0.141 0.574 0.176 0.474 0.189 0.312 0.097 0.163 150185 0.531 0.163 0.423 0.177 0.296 0.091 0.148 0.708 0.217 0.558 0.203 0.340 0.103 0.175 185240 0.689 0.211 0.508 0.197 0.328 0.100 0.169 0.918 0.282 0.672 0.228 0.379 0.114 0.196 240300 0.861 0.264 0.603 0.219 0.366 0.111 0.188 1.148 0.353 0.793 0.251 0.483 0.126 0.215 300400 - 0.353 0.715 0.239 0.424 0.121 0.205 - 0.470 0.937 0.275 0.533 0.137 0.234 400500 - 0.441 0.854 0.263 0.504 0.131 0.225 - 0.588 1.095 0.300 0.643 0.147 0.254 500

* Circular conductors

PAGE 16

Page 20: AECMSA Electrical Cable Price Variation Factors

PAGE 17

Printed 2007/04/03

3,3kV HEAVY DUTY (BELTED) CABLES TO SANS 97 AFAA

1,9/3,3kVSINGLE CORE 3 CORE

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING AREAmm2 OVER OVER & mm2

ARMOUR ARMOUR SERVINGCOMBINED

16 - - - - 0.046* - 0.238 0.117 0.154 0.048 0.084 1625 - - - - 0.072 0.022 0.229 0.116 0.152 0.048 0.083 2535 - - - - 0.100 0.031 0.246 0.123 0.162 0.053 0.088 3550 - - - - 0.144 0.044 0.269 0.131 0.174 0.059 0.100 5070 - - - - 0.201 0.062 0.299 0.142 0.187 0.065 0.106 7095 - - - - 0.273 0.084 0.329 0.154 0.257 0.076 0.126 95

120 - - - - 0.344 0.106 0.391 0.165 0.277 0.083 0.140 120150 0.142 0.044 0.235 0.028 0.431 0.132 0.415 0.176 0.296 0.091 0.147 150185 0.175 0.053 0.256 0.029 0.531 0.163 0.487 0.189 0.316 0.097 0.163 185240 0.228 0.070 0.275 0.036 0.689 0.211 0.570 0.206 0.343 0.105 0.176 240300 0.284 0.087 0.306 0.039 0.861 0.264 0.666 0.228 0.379 0.114 0.198 300400 0.379 0.117 0.339 0.046 - 0.353 0.793 0.247 0.481 0.125 0.212 400500 0.474 0.146 0.400 0.055 - 0.441 0.905 0.268 0.507 0.133 0.229 500630 0.598 0.183 0.441 0.060 - - - - - - - 630

*Circular conductors

PAGE 17

Page 21: AECMSA Electrical Cable Price Variation Factors

PAGE 18

Printed 2007/04/03

3,3kV HEAVY DUTY (BELTED) CABLES TO SANS 97 TABLE 22

3,3/3,3kVSINGLE CORE 3 CORE TABLE 22

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING AREAmm2 OVER OVER & mm2

ARMOUR ARMOUR SERVINGCOMBINED

16 - - - - 0.046* - 0.240 0.118 0.163 0.053 0.087 1625 - - - - 0.072 0.022 0.246 0.117 0.161 0.051 0.086 2535 - - - - 0.100 0.031 0.264 0.124 0.170 0.055 0.093 3550 - - - - 0.144 0.044 0.286 0.133 0.183 0.063 0.102 5070 - - - - 0.201 0.062 0.315 0.144 0.197 0.066 0.111 7095 - - - - 0.273 0.084 0.348 0.155 0.270 0.078 0.129 95

120 - - - - 0.344 0.106 0.402 0.166 0.291 0.085 0.143 120150 0.142 0.044 0.245 0.029 0.431 0.132 0.431 0.180 0.308 0.093 0.151 150185 0.175 0.053 0..267 0.030 0.531 0.163 0.498 0.192 0.327 0.099 0.167 185240 0.228 0.070 0.287 0.037 0.689 0.211 0.587 0.212 0.354 0.108 0.184 240300 0.284 0.087 0.319 0.044 0.861 0.264 0.685 0.232 0.386 0.117 0.200 300400 0.379 0.117 0.380 0.048 - 0.353 0.814 0.251 0.489 0.126 0.215 400500 0.474 0.146 0.413 0.056 - 0.441 0.927 0.277 0.519 0.135 0.232 500630 0.598 0.183 0.453 0.066 - - - - - - 630

*Circular conductors

PAGE 18

Page 22: AECMSA Electrical Cable Price Variation Factors

PAGE 19

Printed 2007/04/03

6,6kV HEAVY DUTY (BELTED) CABLES TO SANS 97 TABLE 13 & 23

3,8/6,6kVSINGLE CORE TABLE 13 3 CORE TABLE 23

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING AREAmm2 OVER OVER & mm2

ARMOUR ARMOUR SERVINGCOMBINED

16 - - - - 0.046* - 0.264 0.130 0.177 0.056 0.096 1625 - - - - 0.072 0.022 0.265 0.129 0.175 0.055 0.095 2535 - - - - 0.100 0.031 0.288 0.134 0.180 0.063 0.102 3550 - - - - 0.144 0.044 0.310 0.142 0.191 0.066 0.111 5070 - - - - 0.201 0.062 0.340 0.155 0.272 0.077 0.127 7095 - - - - 0.273 0.084 0.398 0.169 0.294 0.084 0.142 95

120 - - - - 0.344 0.106 0.433 0.179 0.299 0.092 0.150 120150 0.142 0.054 0.256 0.030 0.431 0.132 0.508 0.191 0.319 0.098 0.165 150185 0.175 0.065 0.276 0.035 0.531 0.163 0.560 0.203 0.340 0.103 0.175 185240 0.228 0.085 0.298 0.038 0.689 0.211 0.624 0.221 0.370 0.112 0.191 240300 0.284 0.106 0.350 0.045 0.861 0.264 0.715 0.241 0.427 0.122 0.208 300400 0.379 0.143 0.382 0.048 - 0.353 0.841 0.260 0.501 0.130 0.224 400500 0.474 0.178 0.420 0.057 - 0.441 0.969 0.282 0.597 0.140 0.240 500630 0.598 0.224 0.484 0.067 - - - - - - - 630

*Circular conductors

PAGE 19

Page 23: AECMSA Electrical Cable Price Variation Factors

PAGE 20

Printed 2007/04/03

6,6kV HEAVY DUTY (BELTED) CABLES TO SANS 97 TABLE 24

3,8/6,6kVSINGLE CORE 3 CORE TABLE 24

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING AREAmm2 OVER OVER & mm2

ARMOUR ARMOUR SERVINGCOMBINED

16 - - - - 0.046* - 0.292 0.139 0.187 0.064 0.104 1625 - - - - 0.072 0.022 0.290 0.138 0.187 0.063 0.103 2535 - - - - 0.100 0.031 0.308 0.142 0.195 0.066 0.105 3550 - - - - 0.144 0.044 0.339 0.151 0.263 0.076 0.126 5070 - - - - 0.201 0.062 0.390 0.163 0.285 0.084 0.141 7095 - - - - 0.273 0.084 0.424 0.174 0.304 0.092 0.149 95

120 - - - - 0.344 0.106 0.485 0.186 0.325 0.098 0.164 120150 0.142 0.044 0.276 0.036 0.431 0.132 0.520 0.195 0.340 0.102 0.172 150185 0.175 0.053 0.298 0.038 0.531 0.163 0.599 0.209 0.363 0.109 0.185 185240 0.228 0.070 0.315 0.044 0.689 0.211 0.696 0.232 0.386 0.117 0.200 240300 0.284 0.087 0.382 0.048 0.861 0.264 0.799 0.251 0.485 0.126 0.215 300400 0.379 0.117 0.411 0.056 - 0.353 0.929 0.272 0.518 0.135 0.232 400500 0.474 0.146 0.475 0.065 - 0.441 1.065 0.291 0.617 0.144 0.248 500630 0.598 0.183 0.558 0.070 - - - - - - - 630

*Circular conductors

PAGE 20

Page 24: AECMSA Electrical Cable Price Variation Factors

PAGE 21

Printed 2007/04/03

11kV HEAVY DUTY (BELTED) CABLES TO SANS 97 TABLES 25 & 26

6,35/11kV EARTHED 11/11kV UNEARTHED3 CORE TABLE 25 3 CORE TABLE 26

RATED COPPER ALUMINIUM LEAD STEEL PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA DSTA SWA SERVING BEDDING DSTA SWA SERVING BEDDING AREAmm2 OVER & OVER & mm2

ARMOUR SERVING ARMOUR SERVINGCOMBINED COMBINED

16 0.046* - 0.319 0.150 0.257 0.071 0.123 0.046* - 0.391 0.168 0.290 0.085 0.142 1625 0.072 0.022 0.319 0.159 0.268 0.071 0.122 0.072 0.022 0.390 0.171 0.296 0.084 0.141 2535 0.100 0.031 0.348 0.161 0.277 0.077 0.128 0.100 0.031 0.423 0.183 0.309 0.090 0.146 3550 0.144 0.044 0.402 0.180 0.296 0.084 0.141 0.144 0.044 0.475 0.189 0.325 0.096 0.161 5070 0.201 0.062 0.433 0.181 0.305 0.092 0.149 0.201 0.062 0.509 0.195 0.334 0.100 0.169 7095 0.273 0.084 0.498 0.192 0.325 0.098 0.165 0.273 0.084 0.592 0.209 0.360 0.108 0.183 95

120 0.344 0.106 0.528 0.205 0.341 0.102 0.173 0.344 0.106 0.623 0.218 0.373 0.111 0.190 120150 0.431 0.132 0.600 0.212 0.367 0.109 0.186 0.431 0.132 0.696 0.230 0.393 0.118 0.200 150185 0.531 0.163 0.677 0.231 0.385 0.114 0.195 0.531 0.163 0.737 0.247 0.473 0.123 0.209 185240 0.689 0.211 0.737 0.241 0.472 0.123 0.209 0.689 0.211 0.855 0.263 0.504 0.130 0.223 240300 0.861 0.264 0.865 0.265 0.501 0.131 0.225 0.861 0.264 0.961 0.283 0.607 0.139 0.238 300400 - 0.353 0.980 0.286 0.612 0.140 0.240 - 0.353 1.092 0.305 0.638 0.148 0.255 400500 - 0.441 1.171 0.310 0.638 0.150 0.258 - 0.441 1.232 0.326 0.690 0.160 0.275 500

* Circular conductors

PAGE 21

Page 25: AECMSA Electrical Cable Price Variation Factors

PAGE 22

Printed 2007/04/03

11kV HEAVY DUTY SCREENED CABLES TO SANS 97 TABLES 14 & 27

6,35/11kVSINGLE CORE TABLE 14 3 CORE TABLE 27

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING AREAmm2 OVER OVER & mm2

ARMOUR ARMOUR SERVINGCOMBINED

16 - - - - 0.046* - 0.317 0.155 0.265 0.071 0.123 1625 - - - - 0.072 0.022 0.316 0.160 0.271 0.070 0.122 2535 - - - - 0.100 0.031 0.340 0.166 0.283 0.077 0.127 3550 - - - - 0.144 0.044 0.391 0.173 0.302 0.084 0.141 5070 - - - - 0.201 0.062 0.423 0.183 0.321 0.092 0.149 7095 - - - - 0.273 0.084 0.497 0.195 0.330 0.098 0.165 95

120 - - - - 0.344 0.106 0.524 0.204 0.341 0.102 0.172 120150 0.142 0.044 0.277 0.038 0.431 0.132 0.601 0.218 0.369 0.109 0.185 150185 0.175 0.053 0.297 0.039 0.531 0.163 0.676 0.231 0.409 0.114 0.195 185240 0.228 0.070 0.315 0.046 0.689 0.211 0.735 0.247 0.474 0.123 0.208 240300 0.284 0.087 0.301 0.054 0.861 0.264 0.843 0.267 0.507 0.131 0.225 300400 0.379 0.117 0.412 0.059 - 0.353 0.970 0.286 0.607 0.140 0.240 400500 0.474 0.146 0.482 0.067 - 0.441 1.108 0.309 0.653 0.149 0.257 500630 0.598 0.183 0.562 0.080 - - - - - - - 630

*Circular conductors

PAGE 22

Page 26: AECMSA Electrical Cable Price Variation Factors

PAGE 23

Printed 2007/04/03

11kV HEAVY DUTY SCREENED CABLES TO SANS 97 AFAA

11/11kVSINGLE CORE 3 CORE

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD STEEL PVC RATEDAREA SERVING DSTA SWA SERVING BEDDING AREAmm2 OVER OVER & mm2

ARMOUR ARMOUR SERVINGCOMBINED

16 - - - - 0.046* - 0.465 0.191 0.322 0.096 0.158 1625 - - - - 0.072 0.022 0.476 0.195 0.328 0.095 0.156 2535 - - - - 0.100 0.031 0.498 0.202 0.338 0.098 0.162 3550 - - - - 0.144 0.044 0.516 0.211 0.354 0.102 0.169 5070 - - - - 0.201 0.062 0.601 0.228 0.376 0.109 0.185 7095 - - - - 0.273 0.084 0.674 0.241 0.394 0.114 0.195 95

120 - - - - 0.344 0.106 0.719 0.251 0.411 0.119 0.203 120150 0.142 0.044 0.329 0.046 0.431 0.132 0.801 0.257 0.485 0.125 0.213 150185 0.175 0.053 0.340 0.048 0.531 0.163 0.855 0.263 0.496 0.130 0.222 185240 0.228 0.070 0.401 0.058 0.689 0.211 0.960 0.281 0.533 0.138 0.236 240300 0.284 0.087 0.466 0.060 0.861 0.264 1.070 0.303 0.638 0.146 0.251 300400 0.379 0.117 0.497 0.069 - 0.353 1.213 0.323 0.679 0.155 0.268 400500 0.474 0.146 0.567 0.080 - 0.441 1.365 0.342 0.721 0.164 0.284 500630 0.598 0.183 0.614 0.086 - - - - - - - 630

*Circular conductors

PAGE 23

Page 27: AECMSA Electrical Cable Price Variation Factors

PAGE 24

Printed 2007/04/03

600/1000V PVC PVC SWA PVC CABLES TO SANS 1507

RATED NUMBER OF CORES RATEDAREA 1 2 3 4 AREAmm2 COPPER STEEL* PVC COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC mm21,5 0.001 - - 0.003 0.016* 0.017* 0.004 0.017* 0.019* 0.006 0.018* 0.021* 1,5

- - - 0.023# 0.018 - 0.025# 0.020# - 0.027# 0.024#2,5 0.002 - - 0.005 0.018* 0.020* 0.007 0.019* 0.022* 0.010 0.025* 0.025* 2,5

- - - 0.028# 0.022# - 0.029# 0.025# - 0.032# 0.028#4 0.004 - - 0.008 0.022* 0.025* 0.011 0.022* 0.027* 0.015 0.034* 0.032* 4

- - - 0.030# 0.026# - 0.032# 0.028# - 0.035# 0.034#6 0.006 - - 0.011 0.032 0.029 0.017 0.034 0.032 0.023 0.037 0.036 610 0.009 - - 0.019 0.037 0.036 0.029 0.039 0.039 0.038 0.043 0.044 1016 0.015 0.016 0.016 0.031 0.039 0.044 0.046 0.059 0.051 0.062 0.066 0.060 1625 0.024 0.018 0.020 0.048 0.043 0.038 0.072 0.066 0.053 0.095 0.073 0.062 2535 0.033 0.030 0.022 0.067 0.058 0.040 0.100 0.072 0.059 0.134 0.103 0.071 3550 0.047 0.034 0.028 0.095 0.073 0.056 0.144 0.104 0.072 0.191 0.118 0.095 5070 0.067 0.038 0.033 0.134 0.101 0.065 0.201 0.116 0.087 0.268 0.133 0.111 7095 0.090 0.058 0.043 0.181 0.115 0.079 0.273 0.132 0.110 0.364 0.151 0.133 95

120 0.114 0.064 0.047 0.230 0.124 0.090 0.344 0.142 0.121 0.459 0.209 0.156 120150 0.142 0.070 0.055 - - - 0.431 0.157 0.140 0.574 0.230 0.187 150185 0.175 0.094 0.061 - - - 0.531 0.213 0.172 0.708 0.251 0.217 185240 0.228 0.107 0.077 - - - 0.609 0.247 0.210 0.918 0.355 0.270 240300 0.284 0.117 0.090 - - - 0.861 0.351 0.257 1.148 0.398 0.326 300400 0.379 0.132 0.109 - - - - - - - - - 400500 0.474 0.145 0.124 - - - - - - - - - 500630 0.598 - - - - - - - - - - - 630800 0.759 - - - - - - - - - - - 8001000 0.948 - - - - - - - - - - - 1000

* 0,9 MM SWA

PAGE 24

∗DC CIRCUITS ONLY#1,25 MM SWA

Page 28: AECMSA Electrical Cable Price Variation Factors

PAGE 25

Printed 2007/04/03

600/1000V PVC PVC SWA PVC CABLES TO SANS 1507

RATED NUMBER OF CORES RATEDAREA 5 6 7 8 9 AREAmm2 COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC mm20,75 0.0036 0.015* 0.017* 0.0043 0.017* 0.017* 0.0050 0.017* 0.017* 0.0057 0.018* 0.019* 0.0065 0.019* 0.021* 0,75

0.027# 0.019# 0.029# 0.022# 0.031# 0.023# 0.033# 0.024# 0.035# 0.026*1.0 0.0048 0.017* 0.018* 0.0058 0.017* 0.018* 0.0068 0.019* 0.021* 0.0078 0.019* 0.021* 0.0087 0.021* 0.022* 1.0

0.029# 0.020* 0.031# 0.024# 0.033# 0.026# 0.035* 0.028# 0.037# 0.027*1,5 0.0073 0.024* 0.024* 0.0087 0.031* 0.026* 0.0102 0.031* 0.027* 0.0110 0.034* 0.030* 0.0130 0.037* 0.035* 1,5

0.031# 0.027# 0.033# 0.030# 0.035# 0.030# 0.037# 0.033# 0.040# 0.037*2,5 0.0120 0.034 0.030 0.0140 0.035 0.033 0.0170 0.036 0.034 0.0190 0.039 0.04 0.0220 0.048 0.041 2,54 0.0190 0.037 0.037 0.0240 0.040 0.039 0.0270 0.041 0.040 0.0310 0.060 0.05 0.0350 0.066 0.056 46 0.0290 0.040 0.040 0.0350 0.060 0.047 0.0400 0.062 0.053 0.0460 0.062 0.06 0.0520 0.071 0.060 6

10 0.0480 0.060 0.056 0.0570 0.066 0.060 0.0680 0.069 0.064 0.0770 0.089 0.06 0.0860 0.101 0.068 1016 0.0770 0.072 0.070 0.0920 0.094 0.076 0.1080 0.098 0.079 0.1230 0.101 0.08 0.1380 0.118 0.088 16

RATED NUMBER OF CORES RATEDAREA 10 12 14 16 19 AREAmm2 COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC mm20,75 0.0072 0.030 0.024 0.0086 0.031 0.025 0.0102 0.033 0.028 0.0110 0.034 0.032 0.0130 0.036 0.034 0,751.0 0.0097 0.035 0.028 0.0110 0.036 0.030 0.0130 0.036 0.030 0.0150 0.036 0.033 0.0180 0.038 0.036 1.01,5 0.0140 0.040 0.035 0.0170 0.041 0.038 0.0210 0.043 0.044 0.0240 0.059 0.051 0.0280 0.060 0.056 1,52,5 0.0250 0.062 0.048 0.0290 0.064 0.053 0.0340 0.067 0.057 0.0390 0.071 0.061 0.0460 0.093 0.071 2,54 0.0390 0.069 0.060 0.0460 0.071 0.062 0.0540 0.095 0.070 0.0620 0.100 0.077 0.0730 0.112 0.085 46 0.0570 0.096 0.063 0.0700 0.100 0.068 - - - - - - - - - 6

10 0.0960 0.109 0.078 Q.116 0.110 0.088 - - - - - - - - - 1016 0.1540 0.122 0.100 0.1850 0.127 0.109 - - - - - - - - - 16

* 0,9mm SWA# 1,25mm SWA

PAGE 25

Page 29: AECMSA Electrical Cable Price Variation Factors

PAGE 26

Printed 2007/04/03

600/1000V PVC PVC SWA PVC CABLES TO SANS 1507

RATED NUMBER OF CORES RATEDAREA 20 21 24 27 AREAmm2 COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC mm20,75 0.014 0.037 0.036 0.015 0.038 0.037 0.017 0.057 0.046 0.019 0.058 0.049 0,751.0 0.019 0.039 0.038 0.021 0.040 0.039 0.024 0.060 0.049 0.027 0.060 0.053 1.01,5 0.029 0.068 0.059 0.031 0.068 0.063 0.035 0.094 0.069 0.039 0.096 0.075 1,52,5 0.048 0.098 0.077 0.051 0.098 0.083 0.058 0.109 0.088 0.066 0.114 0.097 2,54 0.077 0.112 0.091 0.081 0.112 0.100 0.092 0.125 0.110 0.104 0.128 0.121 4

RATED NUMBER OF CORES RATEDAREA 30 33 37 61 AREAmm2 COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC mm20,75 0.022 0.060 0.053 0.024 0.062 0.056 0.027 0.066 0.060 0.044 0.101 0.087 0,751.0 0.029 0.064 0.056 0.032 0.066 0.059 0.036 0.069 0.063 0.059 0.107 0.096 1.01,5 0.044 0.099 0.080 0.048 0.099 0.085 0.053 0.108 0.091 0.088 0.134 0.135 1,52,5 0.073 0.117 0.105 0.080 0.117 0.113 0.090 0.127 0.123 0.148 0.193 0.188 2,54 0.116 0.132 0.129 0.127 0.137 0.139 0.142 0.144 0.148 0.235 0.217 0.221 4

PAGE 26

Page 30: AECMSA Electrical Cable Price Variation Factors

PAGE 27

Printed 2007/04/03

600/1000V PVC PVC SWA/ECC PVC CABLES TO SANS 1507-1990

RATED NUMBER OF CORES RATEDAREA 2 3 4 AREAmm2 COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC mm21,5 0.0051 0.014° 0.017° 0.0065 0.015° 0.019° 0.0079 0.017° 0.021° 1,5

- 0.021* 0.018* - 0.023* 0.020* - 0.025* 0.024*2,5 0.0081 0.016° 0.020° 0.0110 0.017° 0.022° 0.0130 0.018° 0.025° 2,5

- 0.023* 0.022* - 0.024* 0.025* - 0.027* 0.028*4 0.0130 0.016° 0.025° 0.0160 0.017° 0.027° 0.0200 0.029° 0.032° 4

- 0.025* 0.026* - 0.027* 0.028* - 0.030* 0.034*6 0.0180 0.026 0.03 0.0250 0.028 0.032 0.0290 0.030 0.036 610 0.0320 0.026 0.04 0.0410 0.028 0.039 0.0490 0.031 0.044 1016 0.0480 0.026 0.04 0.0660 0.044 0.051 0.0790 0.045 0.060 1625 0.0660 0.026 0.04 0.0910 0.045 0.053 0.1120 0.052 0.062 2535 0.0860 0.036 0.05 0.1200 0.051 0.059 0.1490 0.080 0.071 3550 0.1250 0.043 0.06 0.1740 0.073 0.072 0.2170 0.085 0.095 5070 0.1740 0.063 0.07 0.2410 0.076 0.087 0.3010 0.091 0.111 7095 0.2410 0.059 0.08 0.3320 0.077 0.110 0.4130 0.092 0.133 95

120 0.3120 0.049 0.090 0.4260 0.068 0.121 0.5300 0.127 0.156 120150 - - - 0.5130 0.082 0.140 0.6420 0.147 0.187 150185 - - - 0.6450 0.114 0.172 0.8020 0.143 0.217 185240 - - - 0.8330 0.123 0.210 1.0390 0.213 0.270 240300 - - - 1.0380 0.190 0.257 1.2930 0.225 0.326 300

° 0.9mm SWA* 1.25mm SWA

PAGE 27

Page 31: AECMSA Electrical Cable Price Variation Factors

PAGE 28

Printed 2007/04/03

1,9/3,3kV 3 CORE PVC PVC SWA PVC CABLES TO SANS 1507

1,9/3,3kV

COPPER STEEL PVC

16 0.046 0.099 0.095 1625 0.072 0.104 0.086 2535 0.100 0.111 0.096 3550 0.144 0.122 0.110 5070 0.201 0.134 0.126 7095 0.273 0.147 0.142 95120 0.344 0.157 0.155 120150 0.431 0.213 0.180 150185 0.531 0.228 0.200 185240 0.689 0.251 0.227 240300 0.861 0.346 0.257 300

PAGE 28

RATED AREA mm2

RATED AREA mm2

Page 32: AECMSA Electrical Cable Price Variation Factors

PAGE 29

Printed 2007/04/03

600/1000V STRANDED AL PVC PVC SWA PVC CABLES TO SANS 1507

NUMBER OF CORES1 2 3 4

STEEL* PVC STEEL PVC STEEL PVC STEEL PVC

25 0.0073 0.018 0.020 0.0147 0.043 0.038 0.0220 0.066 0.053 0.0300 0.073 0.062 2535 0.0102 0.030 0.022 0.0210 0.058 0.048 0.0310 0.072 0.059 0.0410 0.103 0.071 3550 0.0145 0.034 0.02B 0.0300 0.073 0.056 0.0440 0.104 0.072 0.0580 0.118 0.095 5070 0.0210 0.038 0.033 0.0410 0.101 0.065 0.0620 0.116 0.087 0.0820 0.133 0.111 7095 0.0280 0.058 0.043 0.0550 0.115 0.079 0.0840 0.132 0.110 0.1120 0.151 0.133 95120 0.0350 0.064 0.047 0.0710 0.124 0.090 0.1060 0.142 0.121 0.1400 0.209 0.156 120150 0.0440 0.070 0.055 - - - 0.1320 0.157 0.140 0.1760 0.230 0.187 150185 0.0530 0.094 0.061 - - - 0.1630 0.213 0.172 0.2170 0.251 0.217 185240 0.0700 0.107 0.077 - - - 0.2110 0.247 0.210 0.2820 0.355 0.270 240300 0.0870 0.117 0.090 - - - 0.2640 0.351 0.257 0.3530 0.398 0.326 300400 0.1170 0.132 0.109 - - - - - - - - - 400500 0.1460 0.145 0.124 - - - - - - - - - 500630 0.1830 - - - - - - - - - - - 630800 0.2330 - - - - - - - - - - - 8001000 0.2910 - - - - - - - - - - - 1000

* DC CIRCUITS ONLY

PAGE 29

RATED AREA mm2

RATED AREA mm2STRANDED

ALUMINIUMSTRANDED ALUMINIUM

STRANDED ALUMINIUM

STRANDED ALUMINIUM

Page 33: AECMSA Electrical Cable Price Variation Factors

PAGE 30

Printed 2007/04/03

600/1000V SOLID AL PVC PVC SWA PVC CABLES TO SANS 1507

NUMBER OF CORES2 3 4

STEEL PVC STEEL PVC STEEL PVC

16 0.009 0.036 0.037 0.013 0.039 0.039 0.017 0.057 0.050 1625 0.014 0.039 0.032 0.021 0.045 0.043 0.028 0.070 0.055 2535 0.019 0.042 0.035 0.030 0.067 0.051 0.039 0.076 0.062 3550 0.028 0.066 0.049 0.042 0.077 0.064 0.056 0.111 0.076 5070 0.039 0.072 0.055 0.058 0.110 0.074 0.078 0.127 0.096 7095 0.053 0.104 0.068 0.080 0.127 0.096 0.107 0.144 0.120 95

120 - - - 0.100 0.134 0.108 0.134 0.157 0.131 120150 - - - 0.126 0.149 0.125 0.168 0.219 0.163 150185 - - - 0.156 0.209 0.154 0.207 0.238 0.195 185240 - - - 0.202 0.233 0.190 0.269 0.342 0.248 240300 - - - 0.252 0.254 0.217 0.336 0.376 0.292 300

PAGE 30

RATED AREA mm2

RATED AREA mm2SOLID

ALUMINIUMSOLID

ALUMINIUMSOLID

ALUMINIUM

Page 34: AECMSA Electrical Cable Price Variation Factors

PAGE 31

Printed 2007/04/03

600/1000V SOLAL PVC PVC SWA/ECC PVC CABLES TO SANS 1507

NUMBER OF CORES2 3 4

COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC

16 0.009 0.011 0.026 0.037 0.013 0.011 0.029 0.039 0.017 0.012 0.047 0.050 1625 0.014 0.011 0.024 0.032 0.021 0.011 0.031 0.043 0.028 0.012 0.053 0.055 2535 0.019 0.011 0.028 0.035 0.030 0.012 0.050 0.051 0.039 0.012 0.060 0.062 3550 0.028 0.019 0.042 0.049 0.042 0.019 0.053 0.064 0.056 0.018 0.086 0.076 5070 0.039 0.030 0.041 0.055 0.058 0.032 0.074 0.074 0.078 0.032 0.089 0.096 7095 0.053 0.041 0.062 0.068 0.080 0.041 0.079 0.096 0.107 0.041 0.099 0.120 95

120 - - - - 0.100 0.041 0.089 0.108 0.134 0.041 0.110 0.131 120150 - - - - 0.126 0.059 0.086 0.125 0.168 0.065 0.148 0.163 150185 - - - - 0.156 0.084 0.119 0.154 0.207 0.084 0.152 0.195 185240 - - - - 0.202 0.084 0.144 0.190 0.269 0.085 0.240 0.248 240300 - - - - 0.252 0.114 0.139 0.217 0.336 0.116 0.247 0.292 300

PAGE 31

RATED AREA mm2

RATED AREA mm2SOLID

ALUMINIUMSOLID

ALUMINIUMSOLID

ALUMINIUM

Page 35: AECMSA Electrical Cable Price Variation Factors

PAGE 32

Printed 2007/04/03

600/1000V PVC PVCT ASA PVC or PVC PVC SWA PVC CABLES to BS 6346

SOLID ALUMINIUM PVC WITH ASA PVC WITH SWA

280 (4X70) 0.078 0.025 0.110 0.067 0.070 280 (4X70)

380 (4X95) 0.107 0.039 0.125 0.084 0.090 380 (4X95)

480 (4X120) 0.134 0.043 0.137 0.098 0.105 480 (4X120)

600 (4X150) 0.168 0.047 0.148 0.108 0.110 600 (4X150)

740 (4X185) 0.207 0.051 0.205 0.124 0.129 740 (4X185)

960 (4X240) 0.269 0.074 0.230 0.149 0.159 960 (4X240)

1200 (4X300) 0.336 0.081 0.250 0.171 0.183 1200 (4X300)

PAGE 32

RATED AREA mm2

ALIMINIUM STRIP ARMOUR

SINGLE WIRE ARMOUR

RATED AREA mm2

Page 36: AECMSA Electrical Cable Price Variation Factors

PAGE 33

Printed 2007/04/03

600/1000V PVC PVCT ASA PVC CABLES to BS 6346

NUMBER OF CORES2 3 4

PVC PVC PVC

16 0.009 0.008 0.028 0.013 0.008 0.028 0.017 0.009 0.033 1625 0.014 0.007 0.027 0.021 0.009 0.036 0.027 0.010 0.044 2535 0.019 0.008 0.032 0.030 0.010 0.042 0.038 0.011 0.051 3550 0.028 0.009 0.040 0.042 0.019 0.054 0.055 0.022 0.066 5070 0.039 0.018 0.044 0.058 0.021 0.062 0.076 0.024 0.076 7095 0.053 0.020 0.057 0.080 0.035 0.079 0.104 0.039 0.095 95

120 - - - 0.100 0.037 0.088 0.131 0.043 0.109 120150 - - - 0.126 0.041 0.107 0.164 0.049 0.129 150185 - - - 0.156 0.045 0.126 0.202 0.071 0.154 185240 - - - 0.202 0.067 0.149 0.262 0.078 0.187 240300 - - - 0.252 0.074 0.177 0.328 0.084 0.222 300

PAGE 33

RATED AREA mm2

RATED AREA mm2SOLID

ALUMINIUMALUMINIUM

STRIP ARMOURSOLID

ALUMINIUMALUMINIUM

STRIP ARMOURSOLID

ALUMINIUMALUMINIUM

STRIP ARMOUR

Page 37: AECMSA Electrical Cable Price Variation Factors

PAGE 34

Printed 2007/04/03

RATED AREA mm2 COPPER PVC RATED AREA mm2

4 0.012 0.011 4

6 0.018 0.015 6

10 0.030 0.018 10

16 0.045 0.021 16

25 0.064 0.028 25

PAGE 34

600/1000V 3 CORE PVC PVC CABLES WITH SPLIT-CONCENTRIC NEUTRAL & EARTH CONDUCTORS TO SANS 1507

Page 38: AECMSA Electrical Cable Price Variation Factors

PAGE 35

Printed 2007/04/03

3.8/6.6kV SINGLE CORE TYPE A CABLE TO SANS 1339

Copper* XLPE AWA Diameter AWA PVC Aluminium# Copper Tape°50 0.0513 0.0200 1.60 mm 0.0242 0.0402 0.0376 0.0067 5070 0.0717 0.0224 1.60 mm 0.0259 0.0429 0.0452 0.0073 7095 0.0973 0.0250 1.60 mm 0.0277 0.0474 0.0545 0.0080 95120 0.1214 0.0271 1.60 mm 0.0291 0.0498 0.0630 0.0085 120150 0.1484 0.0295 1.60 mm 0.0308 0.0544 0.0722 0.0091 150185 0.1840 0.0319 2.0 mm 0.0418 0.0541 0.0942 0.0097 185240 0.2397 0.0363 2.0 mm 0.0446 0.0649 0.1129 0.0106 240300 0.2990 0.0422 2.0 mm 0.0486 0.0681 0.1345 0.0116 300400 0.3813 0.0495 2.0 mm 0.0528 0.0823 0.1628 0.0129 400500 0.4869 0.0568 2.5 mm 0.0728 0.0982 0.2142 0.0141 500630 0.6425 0.0626 2.5 mm 0.0785 0.1107 0.2611 0.0154 630800 0.8290 0.0692 2.5 mm 0.0848 0.1238 0.3242 0.0168 800

1000 1.0380 0.0762 2.5 mm 0.0917 0.1427 0.3934 0.0182 1000

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor including aluminium wire armour°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 35

mm2 mm2

Page 39: AECMSA Electrical Cable Price Variation Factors

PAGE 36

Printed 2007/04/03

6.35/11kV SINGLE CORE TYPE A CABLE TO SANS 1339

Copper* XLPE AWA Diameter AWA PVC Aluminium# Copper Tape°50 0.0520 0.0261 1.6000 0.0263 0.0436 0.0397 0.0075 5070 0.0724 0.0290 1.6000 0.0280 0.0479 0.0473 0.0081 7095 0.0980 0.0321 1.6000 0.0298 0.0509 0.0566 0.0087 95120 0.1222 0.0346 2.0000 0.0313 0.0551 0.0651 0.0092 120150 0.1492 0.0376 2.0000 0.0417 0.0639 0.0831 0.0098 150185 0.1847 0.0405 2.0000 0.0438 0.0638 0.0962 0.0104 185240 0.2404 0.0447 2.0000 0.0469 0.0713 0.1152 0.0112 240300 0.2995 0.0487 2.0000 0.0498 0.0755 0.1357 0.0121 300400 0.3816 0.0546 2.5000 0.0540 0.0866 0.1640 0.0132 400500 0.4871 0.0599 2.5000 0.0734 0.0990 0.2149 0.0143 500630 0.6426 0.0659 2.5000 0.0794 0.1118 0.2620 0.0155 630800 0.8292 0.0728 2.5000 0.0856 0.1233 0.3250 0.0169 800

1000 1.0382 0.0802 2.5000 0.0926 0.1440 0.3942 0.0184 1000

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor including aluminium wire armour°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 36

mm2 mm2

Page 40: AECMSA Electrical Cable Price Variation Factors

PAGE 37

Printed 2007/04/03

8.7/15kV SINGLE CORE TYPE A CABLE TO SANS 1339 AFAA

Copper* XLPE AWA Diameter AWA PVC Aluminium# Copper Tape°50 0.0529 0.0341 1.60 0.0288 0.0493 0.0422 0.0084 5070 0.0733 0.0377 1.60 0.0305 0.0521 0.0499 0.0090 7095 0.0989 0.0414 2.00 0.0409 0.0578 0.0678 0.0096 95120 0.1231 0.0445 2.00 0.0428 0.0634 0.0766 0.0101 120150 0.1501 0.0481 2.00 0.0449 0.0663 0.0862 0.0107 150185 0.1856 0.0516 2.00 0.0470 0.0715 0.0994 0.0113 185240 0.2413 0.0567 2.00 0.0500 0.0782 0.1183 0.0121 240300 0.3004 0.0615 2.00 0.0529 0.0825 0.1388 0.0129 300400 0.3825 0.0686 2.50 0.0728 0.0982 0.1828 0.0141 400500 0.4880 0.0750 2.50 0.0776 0.1072 0.2190 0.0152 500630 0.6435 0.0823 2.50 0.0833 0.1202 0.2659 0.0164 630800 0.8301 0.0907 2.50 0.0899 0.1367 0.3293 0.0178 800

1000 1.0391 0.0995 2.50 0.0969 0.1567 0.3985 0.0193 1000

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor including aluminium wire armour°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 37

mm2 mm2

Page 41: AECMSA Electrical Cable Price Variation Factors

PAGE 38

Printed 2007/04/03

12.7/22kV SINGLE CORE TYPE A CABLE TO SANS 1339

Copper* XLPE AWA Diameter AWA PVC Aluminium# Copper Tape°50 0.0537 0.0424 1.60 0.0312 0.0549 0.0446 0.0092 5070 0.0741 0.0465 2.00 0.0416 0.0587 0.0609 0.0098 7095 0.0997 0.0508 2.00 0.0438 0.0648 0.0707 0.0104 95120 0.1239 0.0544 2.00 0.0457 0.0674 0.0796 0.0109 120150 0.1509 0.0585 2.00 0.0478 0.0726 0.0891 0.0115 150185 0.1864 0.0626 2.00 0.0499 0.0757 0.1023 0.0121 185240 0.2421 0.0685 2.00 0.0529 0.0825 0.1212 0.0129 240300 0.3012 0.0741 2.50 0.0711 0.0921 0.1570 0.0138 300400 0.3833 0.0823 2.50 0.0764 0.1028 0.1864 0.0149 400500 0.4888 0.0897 2.50 0.0815 0.1147 0.2230 0.0160 500630 0.6443 0.0982 2.50 0.0870 0.1284 0.2696 0.0172 630800 0.8309 0.1079 2.50 0.0936 0.1454 0.3329 0.0186 800

1000 1.0399 0.1181 2.50 0.1005 0.1623 0.4021 0.0201 1000

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor including aluminium wire armour°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 38

mm2 mm2

Page 42: AECMSA Electrical Cable Price Variation Factors

PAGE 39

Printed 2007/04/03

19/33kV SINGLE CORE TYPE A CABLE TO SANS 1339

Copper* XLPE AWA Diameter AWA PVC Aluminium# Copper Tape°50 0.0558 0.0663 2.00 0.0467 0.0711 0.0601 0.0112 5070 0.0761 0.0718 2.00 0.0488 0.0742 0.0682 0.0118 7095 0.1017 0.0776 2.00 0.0511 0.0798 0.0779 0.0124 95120 0.1259 0.0824 2.00 0.0529 0.0825 0.0868 0.0129 120150 0.1529 0.0879 2.50 0.0701 0.0908 0.1115 0.0135 150185 0.1885 0.0934 2.50 0.0728 0.0982 0.1251 0.0141 185240 0.2441 0.1013 2.50 0.0766 0.1030 0.1449 0.0150 240300 0.3032 0.1088 2.50 0.0805 0.1133 0.1664 0.0158 300400 0.3854 0.1198 2.50 0.0858 0.1236 0.1958 0.0170 400500 0.4908 0.1298 2.50 0.0909 0.1382 0.2324 0.0181 500630 0.6464 0.1411 2.50 0.0964 0.1496 0.2790 0.0193 630800 0.8329 0.1542 3.15 0.1311 0.1722 0.3704 0.0207 800

1000 1.0420 0.1679 3.15 0.1398 0.1923 0.4414 0.0222 1000

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor including aluminium wire armour°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 39

mm2 mm2

Page 43: AECMSA Electrical Cable Price Variation Factors

PAGE 40

Printed 2007/04/03

3.8/6.6kV SINGLE CORE TYPE A2 CABLE TO SANS 1339 AFAA

Copper* XLPE PVC Aluminium# Copper Tape°50 0.0580 0.0200 0.0174 0.0134 0.0135 5070 0.0790 0.0224 0.0200 0.0194 0.0146 7095 0.1052 0.0250 0.0216 0.0268 0.0159 95120 0.1299 0.0271 0.0243 0.0339 0.0169 120150 0.1575 0.0295 0.0258 0.0414 0.0181 150185 0.1937 0.0319 0.0290 0.0524 0.0193 185240 0.2503 0.0363 0.0314 0.0683 0.0212 240300 0.3106 0.0422 0.0360 0.0859 0.0232 300400 0.3942 0.0495 0.0440 0.1100 0.0258 400500 0.5010 0.0568 0.0502 0.1415 0.0283 500630 0.6578 0.0626 0.0566 0.1826 0.0307 630800 0.8458 0.0692 0.0641 0.2394 0.0335 8001000 1.0563 0.0762 0.0723 0.3016 0.0365 1000

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 40

mm2 mm2

Page 44: AECMSA Electrical Cable Price Variation Factors

PAGE 41

Printed 2007/04/03

6,35/11kV single core type A2 cable to SANS 1339 AFAA

Copper* XLPE PVC Aluminium# Copper Tape°50 0.0595 0.0261 0.0204 0.0134 0.0149 5070 0.0805 0.0290 0.0218 0.0194 0.0161 7095 0.1067 0.0321 0.0248 0.0268 0.0174 95120 0.1314 0.0346 0.0261 0.0339 0.0184 120150 0.1590 0.0376 0.0293 0.0414 0.0196 150185 0.1951 0.0405 0.0309 0.0524 0.0208 185240 0.2516 0.0447 0.0351 0.0683 0.0225 240300 0.3115 0.0487 0.0393 0.0859 0.0241 300400 0.3949 0.0546 0.0450 0.1100 0.0265 400500 0.5014 0.0599 0.0506 0.1415 0.0286 500630 0.6582 0.0659 0.0572 0.1826 0.0311 630800 0.8461 0.0728 0.0647 0.2394 0.0339 8001000 1.0567 0.0802 0.0729 0.3016 0.0368 1000

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 41

mm2 mm2

Page 45: AECMSA Electrical Cable Price Variation Factors

PAGE 42

Printed 2007/04/03

8,7/15kV single core type A2 cable to SANS 1339 AFAA

Copper* XLPE PVC Aluminium# Copper Tape°50 0.0613 0.0341 0.0225 0.0134 0.0167 5070 0.0823 0.0377 0.0255 0.0194 0.0179 7095 0.1085 0.0414 0.0288 0.0268 0.0192 95120 0.1332 0.0445 0.0301 0.0339 0.0202 120150 0.1608 0.0481 0.0335 0.0414 0.0214 150185 0.1969 0.0516 0.0352 0.0524 0.0226 185240 0.2534 0.0567 0.0396 0.0683 0.0243 240300 0.3133 0.0615 0.0441 0.0859 0.0259 300400 0.3967 0.0686 0.0502 0.1100 0.0283 400500 0.5032 0.0750 0.0561 0.1415 0.0304 500630 0.6600 0.0823 0.0629 0.1826 0.0328 630800 0.8479 0.0907 0.0707 0.2394 0.0357 8001000 1.0584 0.0995 0.0792 0.3016 0.0386 1000

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 42

mm2 mm2

Page 46: AECMSA Electrical Cable Price Variation Factors

PAGE 43

Printed 2007/04/03

12,7/22kV single core type A2 cable to SANS 1339 AFAA

Copper* XLPE PVC Aluminium# Copper Tape°50 0.0629 0.0424 0.0261 0.0134 0.0183 5070 0.0839 0.0465 0.0292 0.0194 0.0195 7095 0.1101 0.0508 0.0309 0.0268 0.0208 95120 0.1348 0.0544 0.0341 0.0339 0.0218 120150 0.1624 0.0585 0.0358 0.0414 0.0230 150185 0.1985 0.0626 0.0394 0.0524 0.0242 185240 0.2550 0.0685 0.0441 0.0683 0.0259 240300 0.3150 0.0741 0.0466 0.0859 0.0275 300400 0.3983 0.0823 0.0528 0.1100 0.0299 400500 0.5048 0.0897 0.0589 0.1415 0.0320 500630 0.6616 0.0982 0.0657 0.1826 0.0345 630800 0.8495 0.1079 0.0766 0.2394 0.0373 8001000 1.0601 0.1181 0.0856 0.3016 0.0402 1000

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 43

mm2 mm2

Page 47: AECMSA Electrical Cable Price Variation Factors

PAGE 44

Printed 2007/04/03

19/33kV single core type A2 cable to SANS 1339 AFAA

Copper* XLPE PVC Aluminium# Copper Tape°50 0.0670 0.0663 0.0350 0.0134 0.0224 5070 0.0879 0.0718 0.0366 0.0194 0.0236 7095 0.1142 0.0776 0.0404 0.0268 0.0249 95120 0.1389 0.0824 0.0420 0.0339 0.0259 120150 0.1664 0.0879 0.0459 0.0414 0.0271 150185 0.2026 0.0934 0.0478 0.0524 0.0283 185240 0.2591 0.1013 0.0529 0.0683 0.0300 240300 0.3190 0.1088 0.0581 0.0859 0.0316 300400 0.4023 0.1198 0.0648 0.1100 0.0340 400500 0.5089 0.1298 0.0715 0.1415 0.0361 500630 0.6657 0.1411 0.0790 0.1826 0.0385 630800 0.8536 0.1542 0.0878 0.2394 0.0414 8001000 1.0641 0.1679 0.1007 0.3016 0.0443 1000

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 44

mm2 mm2

Page 48: AECMSA Electrical Cable Price Variation Factors

PAGE 45

Printed 2007/04/03

3,8/6,6kV single core type B cables to SANS 1339

Copper* XLPE PVC Aluminium# Copper Tape°50 0.0647 0.0200 0.0176 0.0134 0.0202 5070 0.0863 0.0224 0.0202 0.0194 0.0220 7095 0.1132 0.0250 0.0216 0.0268 0.0239 95120 0.1384 0.0271 0.0243 0.0339 0.0254 120150 0.1575 0.0295 0.0258 0.0414 0.0181 150185 0.1937 0.0319 0.0290 0.0524 0.0193 185240 0.2503 0.0363 0.0314 0.0683 0.0212 240300 0.3106 0.0422 0.0360 0.0859 0.0232 300400 0.3942 0.0495 0.0440 0.1100 0.0258 400500 0.5010 0.0568 0.0502 0.1415 0.0283 500630 0.6578 0.0626 0.0566 0.1826 0.0307 630800 0.8458 0.0692 0.0641 0.2394 0.0335 8001000 1.0563 0.0762 0.0723 0.3016 0.0365 1000

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 45

mm2 mm2

Page 49: AECMSA Electrical Cable Price Variation Factors

PAGE 46

Printed 2007/04/03

6,35/11kV single core type B cable to SANS 1339

Copper* XLPE PVC Aluminium# Copper Tape°50 0.0670 0.0261 0.0207 0.0134 0.0224 5070 0.0885 0.0290 0.0221 0.0194 0.0242 7095 0.1154 0.0321 0.0251 0.0268 0.0261 95120 0.1406 0.0346 0.0264 0.0339 0.0276 120150 0.1688 0.0376 0.0296 0.0414 0.0294 150185 0.2055 0.0405 0.0312 0.0524 0.0312 185240 0.2629 0.0447 0.0354 0.0683 0.0337 240300 0.3115 0.0487 0.0393 0.0859 0.0241 300400 0.3949 0.0546 0.0450 0.1100 0.0265 400500 0.5014 0.0599 0.0506 0.1415 0.0286 500630 0.6582 0.0659 0.0572 0.1826 0.0311 630800 0.8461 0.0728 0.0647 0.2394 0.0339 8001000 1.0567 0.0802 0.0729 0.3016 0.0368 1000

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 46

mm2 mm2

Page 50: AECMSA Electrical Cable Price Variation Factors

PAGE 47

Printed 2007/04/03

8,7/15kV single core type B cable to SANS 1339

Copper* XLPE PVC Aluminium# Copper Tape°50 0.0696 0.0341 0.0228 0.0134 0.0251 5070 0.0912 0.0377 0.0258 0.0194 0.0269 7095 0.1181 0.0414 0.0290 0.0268 0.0287 95120 0.1433 0.0445 0.0304 0.0339 0.0303 120150 0.1608 0.0481 0.0335 0.0414 0.0214 150185 0.1969 0.0516 0.0352 0.0524 0.0226 185240 0.2534 0.0567 0.0396 0.0683 0.0243 240300 0.3133 0.0615 0.0441 0.0859 0.0259 300400 0.3967 0.0686 0.0502 0.1100 0.0283 400500 0.5032 0.0750 0.0561 0.1415 0.0304 500630 0.6600 0.0823 0.0629 0.1826 0.0328 630800 0.8479 0.0907 0.0707 0.2394 0.0357 8001000 1.0584 0.0995 0.0792 0.3016 0.0386 1000

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 47

mm2 mm2

Page 51: AECMSA Electrical Cable Price Variation Factors

PAGE 48

Printed 2007/04/03

12,7/22kV single core type B cable to SANS 1339

Copper* XLPE PVC Aluminium# Copper Tape°50 0.0721 0.0424 0.0264 0.0134 0.0275 5070 0.0936 0.0465 0.0295 0.0194 0.0293 7095 0.1205 0.0508 0.0312 0.0268 0.0312 95120 0.1457 0.0544 0.0344 0.0339 0.0327 120150 0.1739 0.0585 0.0361 0.0414 0.0345 150185 0.1985 0.0626 0.0394 0.0524 0.0242 185240 0.2550 0.0685 0.0441 0.0683 0.0259 240300 0.3150 0.0741 0.0466 0.0859 0.0275 300400 0.3983 0.0823 0.0528 0.1100 0.0299 400500 0.5048 0.0897 0.0589 0.1415 0.0320 500630 0.6616 0.0982 0.0657 0.1826 0.0345 630800 0.8495 0.1079 0.0766 0.2394 0.0373 8001000 1.0601 0.1181 0.0856 0.3016 0.0402 1000

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 48

mm2 mm2

Page 52: AECMSA Electrical Cable Price Variation Factors

PAGE 49

Printed 2007/04/03

19/33kV single core type B cable to SANS 1339

Copper* XLPE PVC Aluminium# Copper Tape°50 0.0726 0.0663 0.0350 0.0134 0.0280 5070 0.0879 0.0718 0.0366 0.0194 0.0236 7095 0.1142 0.0776 0.0404 0.0268 0.0249 95120 0.1389 0.0824 0.0420 0.0339 0.0259 120150 0.1664 0.0879 0.0459 0.0414 0.0271 150185 0.2026 0.0934 0.0478 0.0524 0.0283 185240 0.2591 0.1013 0.0529 0.0683 0.0300 240300 0.3190 0.1088 0.0581 0.0859 0.0316 300400 0.4023 0.1198 0.0648 0.1100 0.0340 400500 0.5089 0.1298 0.0715 0.1415 0.0361 500630 0.6657 0.1411 0.0790 0.1826 0.0385 630800 0.8536 0.1542 0.0878 0.2394 0.0414 8001000 1.0641 0.1679 0.1007 0.3016 0.0443 1000

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 49

mm2 mm2

Page 53: AECMSA Electrical Cable Price Variation Factors

PAGE 50

Printed 2007/04/03

3.8/6.6kV THREE-CORE TYPE A CABLE TO SANS 1339

Copper* XLPE SWA Diameter SWA PVC Aluminium# Copper Tape°16 0.0614 0.0433 2.0 0.1388 0.0740 1625 0.0885 0.0487 2.0 0.1488 0.0791 0.0215 0.0174 2535 0.1175 0.0537 2.0 0.1576 0.0864 0.0298 0.0186 3550 0.1541 0.0600 2.5 0.2152 0.1029 0.0404 0.0202 5070 0.2154 0.0673 2.5 0.2315 0.1137 0.0582 0.0220 7095 0.2924 0.0750 2.5 0.2502 0.1281 0.0806 0.0239 95120 0.3650 0.0813 2.5 0.2660 0.1414 0.1019 0.0254 120150 0.4462 0.0886 2.5 0.2823 0.1550 0.1243 0.0272 150185 0.5530 0.0958 3.15 0.3820 0.1733 0.1574 0.0290 185240 0.7204 0.1089 3.15 0.4164 0.2014 0.2054 0.0317 240300 0.8988 0.1265 3.15 0.4521 0.2372 0.2583 0.0347 300

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 50

mm2 mm2

Page 54: AECMSA Electrical Cable Price Variation Factors

PAGE 51

Printed 2007/04/03

6.35/11kV THREE-CORE TYPE A CABLE TO SANS 1339

Copper* XLPE SWA Diameter SWA PVC Aluminium# Copper Tape°16 0.0636 0.0579 2.0 0.1553 0.0849 5025 0.0907 0.0644 2.5 0.2099 0.0965 0.0215 0.0196 7035 0.1198 0.0705 2.5 0.2210 0.1045 0.0298 0.0209 9550 0.1563 0.0782 2.5 0.2368 0.1181 0.0404 0.0224 12070 0.2176 0.0869 2.5 0.2531 0.1295 0.0582 0.0242 15095 0.2946 0.0962 2.5 0.2718 0.1460 0.0806 0.0261 185120 0.3672 0.1039 2.5 0.2876 0.1642 0.1019 0.0276 240150 0.4484 0.1127 3.15 0.3868 0.1812 0.1243 0.0294 300185 0.5552 0.1215 3.15 0.4092 0.1965 0.1574 0.0312 400240 0.7224 0.1341 3.15 0.4406 0.2270 0.2054 0.0337 500300 0.9002 0.1462 3.15 0.4708 0.2550 0.2583 0.0362 630

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 51

mm2 mm2

Page 55: AECMSA Electrical Cable Price Variation Factors

PAGE 52

Printed 2007/04/03

8.7/15kV THREE-CORE TYPE A CABLE TO SANS 1339 AFAA

Copper* XLPE SWA Diameter SWA PVC Aluminium# Copper Tape°25 0.0934 0.0858 2.5 0.2358 0.1176 0.0215 0.0223 2535 0.1224 0.0931 2.5 0.2473 0.1263 0.0298 0.0235 3550 0.1589 0.1024 2.5 0.2627 0.1413 0.0404 0.0251 5070 0.2202 0.1130 2.5 0.2804 0.1567 0.0582 0.0269 7095 0.2973 0.1243 3.15 0.3808 0.1757 0.0806 0.0287 95120 0.3699 0.1336 3.15 0.3989 0.1877 0.1019 0.0303 120150 0.4511 0.1442 3.15 0.4213 0.2070 0.1243 0.0321 150185 0.5579 0.1548 3.15 0.4436 0.2320 0.1574 0.0338 185240 0.7251 0.1700 3.55 0.5380 0.2625 0.2054 0.0364 240300 0.9029 0.1846 3.55 0.5714 0.2897 0.2583 0.0388 300

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 52

mm2 mm2

Page 56: AECMSA Electrical Cable Price Variation Factors

PAGE 53

Printed 2007/04/03

12.7/22kV THREE-CORE TYPE A CABLE TO SANS 1339

Copper* XLPE SWA Diameter SWA PVC Aluminium# Copper Tape°35 0.1249 0.1163 2.5 0.2713 0.1441 0.0298 0.0260 3550 0.1614 0.1271 2.5 0.2857 0.1568 0.0404 0.0275 5070 0.2227 0.1394 3.15 0.3862 0.1766 0.0582 0.0293 7095 0.2997 0.1524 3.15 0.4098 0.1983 0.0806 0.0312 95120 0.3723 0.1632 3.15 0.4279 0.2110 0.1019 0.0327 120150 0.4535 0.1754 3.15 0.4502 0.2296 0.1243 0.0345 150185 0.5603 0.1877 3.15 0.4720 0.2556 0.1574 0.0363 185240 0.7275 0.2054 3.55 0.5700 0.2851 0.2054 0.0388 240300 0.9054 0.2223 3.55 0.6027 0.3087 0.2583 0.0413 300

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 53

mm2 mm2

Page 57: AECMSA Electrical Cable Price Variation Factors

PAGE 54

Printed 2007/04/03

19/33kV THREE-CORE TYPE A CABLE TO SANS 1339

Copper* XLPE SWA Diameter SWA PVC Aluminium# Copper Tape°50 0.1675 0.1988 3.15 0.4394 0.1934 0.0404 0.0336 5070 0.2288 0.2153 3.15 0.4605 0.2415 0.0582 0.0354 7095 0.3058 0.2328 3.55 0.5483 0.2636 0.0806 0.0373 95120 0.3784 0.2472 3.55 0.5700 0.2851 0.1019 0.0388 120150 0.4596 0.2637 3.55 0.5939 0.2992 0.1243 0.0406 150185 0.5664 0.2802 3.55 0.6184 0.3235 0.1574 0.0424 185240 0.7337 0.3039 3.55 0.6538 0.3601 0.2054 0.0449 240300 0.9114 0.3265 3.55 0.6878 0.3974 0.2583 0.0474 300

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 54

mm2 mm2

Page 58: AECMSA Electrical Cable Price Variation Factors

PAGE 55

Printed 2007/04/03

3.8/6.6kV THREE-CORE TYPE B CABLE TO SANS 1339

Copper* XLPE PVC Aluminium# Copper Tape°16 0.0775 0.0433 0.0395 1625 0.1059 0.0487 0.0445 0.0215 0.0322 2535 0.1362 0.0537 0.0496 0.0298 0.0348 3550 0.1743 0.0600 0.0557 0.0404 0.0373 5070 0.2373 0.0673 0.0640 0.0582 0.0404 7095 0.2924 0.0750 0.0710 0.0806 0.0439 95120 0.3650 0.0813 0.0782 0.1019 0.0239 120150 0.4461 0.0886 0.0878 0.1243 0.0254 150185 0.5530 0.0958 0.0966 0.1574 0.0272 185240 0.7204 0.1089 0.1124 0.2054 0.0290 240300 0.8988 0.1265 0.1320 0.2583 0.0317 300

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 55

mm2 mm2

Page 59: AECMSA Electrical Cable Price Variation Factors

PAGE 56

Printed 2007/04/03

6.35/11kV THREE-CORE TYPE B CABLE TO SANS 1339

Copper* XLPE PVC Aluminium# Copper Tape°16 0.0819 0.0579 0.0487 1625 0.1103 0.0644 0.0520 0.0215 0.0366 2535 0.1406 0.0705 0.0585 0.0298 0.0393 3550 0.1787 0.0782 0.0639 0.0404 0.0417 5070 0.2418 0.0869 0.0727 0.0582 0.0448 7095 0.2946 0.0962 0.0844 0.0806 0.0484 95120 0.3672 0.1039 0.0908 0.1019 0.0261 120150 0.4483 0.1127 0.1012 0.1243 0.0276 150185 0.5552 0.1215 0.1106 0.1574 0.0294 185240 0.7224 0.1341 0.1247 0.2054 0.0312 240300 0.9002 0.1462 0.1394 0.2583 0.0337 300

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 56

mm2 mm2

Page 60: AECMSA Electrical Cable Price Variation Factors

PAGE 57

Printed 2007/04/03

8.7/15kV THREE-CORE TYPE B CABLE TO SANS 1339 AFAA

Copper* XLPE PVC Aluminium# Copper Tape°25 0.0934 0.0858 0.0640 0.0215 0.0223 2535 0.1224 0.0931 0.0700 0.0298 0.0235 3550 0.1589 0.1024 0.0785 0.0404 0.0251 5070 0.2202 0.1130 0.0854 0.0582 0.0269 7095 0.2973 0.1243 0.0943 0.0806 0.0287 95120 0.3699 0.1336 0.1042 0.1019 0.0303 120150 0.4510 0.1442 0.1135 0.1243 0.0321 150185 0.5579 0.1548 0.1233 0.1574 0.0338 185240 0.7251 0.1700 0.1403 0.2054 0.0364 240300 0.9029 0.1846 0.1600 0.2583 0.0388 300

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 57

mm2 mm2

Page 61: AECMSA Electrical Cable Price Variation Factors

PAGE 58

Printed 2007/04/03

12.7/22kV THREE-CORE TYPE B CABLE TO SANS 1339

Copper* XLPE PVC Aluminium# Copper Tape°35 0.1249 0.1163 0.0857 0.0298 0.0260 3550 0.1614 0.1271 0.0952 0.0404 0.0275 5070 0.2227 0.1394 0.1042 0.0582 0.0293 7095 0.2997 0.1524 0.1141 0.0806 0.0312 95120 0.3723 0.1632 0.1249 0.1019 0.0327 120150 0.4534 0.1754 0.1392 0.1243 0.0345 150185 0.5603 0.1877 0.1500 0.1574 0.0363 185240 0.7275 0.2054 0.1709 0.2054 0.0388 240300 0.9053 0.2223 0.1835 0.2583 0.0413 300

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 58

mm2 mm2

Page 62: AECMSA Electrical Cable Price Variation Factors

PAGE 59

Printed 2007/04/03

19/33kV THREE-CORE TYPE B CABLE TO SANS 1339

Copper* XLPE PVC Aluminium# Copper Tape°50 0.1675 0.1988 0.1302 0.0404 0.0336 5070 0.2288 0.2153 0.1426 0.0582 0.0354 7095 0.3058 0.2328 0.1540 0.0806 0.0373 95120 0.3784 0.2472 0.1709 0.1019 0.0388 120150 0.4595 0.2637 0.1807 0.1243 0.0406 150185 0.5664 0.2802 0.1952 0.1574 0.0424 185240 0.7337 0.3039 0.2165 0.2054 0.0449 240300 0.9114 0.3265 0.2381 0.2583 0.0474 300

*variation factor applies to a copper conductor including copper tape screen#variation factor applies to an aluminium conductor°variation factor for a copper tape screen applied to a cable with an aluminium conductor

PAGE 59

mm2 mm2

Page 63: AECMSA Electrical Cable Price Variation Factors

PAGE 60

Printed 2007/04/03

STANDARD SIGNALLING CABLES (OUTDOOR) TO SATS SPECIFICATION NO CSE 49E

SIZECORES 2 3 4 6 9 12 16 21 27 37 52 61COPPER 0.0013 0.0020 0.0025 0.0038 0.0054 0.0077 0.010 0.014 0.017 0.024 0.034 0.039PVC 0.0150 0.0160 0.0170 0.0210 0.0270 0.0320 0.039 0.046 0.054 0.075 0.098 0.110SWA 0.0150 0.0160 0.0170 0.0200 0.0330 0.0350 0.038 0.029* 0.033* 0.037* 0.043* 0.044*

SIZECORES 2 3 4 6 9 10 16 21 27 37 52 61COPPER 0.0030 0.0045 0.006 0.009 0.014 0.018 0.024 0.032 0.041 0.056 0.079 0.093PVC 0.017 0.0190 0.021 0.025 0.033 0.039 0.046 0.061 0.075 0.094 0.129 0.149SWA 0.017 0.0180 0.019 0.023 0.034 0.017 0.025* 0.033* 0.037* 0.041* 0.048* 0.052*

SIZE 1,6mm2CORES 2 3 4 6 9 12 16 21 27 37 52 61COPPER 0.004 0.006 0.008 0.012 0.017 0.024 0.032 0.042 0.053 0.073 0.102 0.121PVC 0.019 0.021 0.025 0.030 0.040 0.045 0.059 0.074 0.087 0.113 0.160 0.175SWA 0.018 0.019 0.021 0.034 0.018* 0.029* 0.033* 0.037* 0.041* 0.045* 0.054* 0.058*

SIZE 2,5mm2 SIZE 4mm2CORES 2 3 4 37 CORES 2 3 4 6 9 12 21COPPER 0.0051 0.0078 0.010 0.094 COPPER 0.008 0.012 0.016 0.023 0.035 0.047 0.083PVC 0.0230 0.0250 0.028 0.123 PVC 0.026 0.028 0.032 0.037 0.057 0.066 0.096SWA 0.0210 0.0220 0.024 - SWA 0.023 0.024 0.035 0.020 0.026 0.030 0.036*

SIZE 6mm2 SIZE 10mm2 16mm2CORES 2 3 4 6 CORES 2 4 12 2 3 4 6COPPER 0.012 0.018 0.024 0.035 COPPER 0.020 0.040 0.120 0.031 0.048 0.062 0.073PVC 0.032 0.036 0.038 0.049 PVC 0.036 0.041 0.090 0.043 0.051 0.058 0.073SWA 0.032 0.035 0.038 0.030 SWA 0.039 0.023* 0.043* 0.028* 0.031* 0.033* 0.037*

*Galvanised Ferrous Tape

PAGE 60

0,9mm2

1,4mm2

Page 64: AECMSA Electrical Cable Price Variation Factors

PAGE 61

Printed 2007/04/03

STANDARD SIGNALLING CABLES (INDOOR) TO SATS SPECIFICATION NO CSE 49G

SIZE CORES COPPER PVC0,5mm2 50 0.0110 0.0210

70 0.0140 0.02500,63mm2 12 0.0030 0.0100

20 0.0060 0.012060 0.0170 0.021068 0.0210 0.030080 0.0230 0.0330

0,9mm2 1 0.0010 0.00094 0.0025 0.012010 0.0060 0.015020 0.0120 0.0180

16mm2 1 0.0150 0.010012 0.1800 0.0750

35mm2 1 0.0320 0.02102 0.0650 0.05103 0.0980 0.05306 0.1980 0.114012 0.3960 0.1730

70mm2 2 0.1310 0.05903 0.1960 0.0710

PAGE 61


Recommended