We, at DENTIS, strive to build a “Safe & Clean
Implant”image to our dental professionals and
patients. We aim to manufacture the safest & cleanest
implant products in the world.
060810
12141518
24262829
3032527284
8890929496979899104105
CONTENTSCleanlant System Ⅰ. Cleanlant System Selection
1. Fixture System2. Abutment System
II. Features of Cleanlant1. Surface Treatment2. Cleaning System3. Features of Implant
III. Uses of Cleanlant Abutment System1. Uses of i-Clean Abutment2. Uses of s-Clean Abutment3. Uses of e-Clean Abutment
IV. Cleanlant System Flow_ i-Clean System(Tapered & Straight) & SAVE_ s-Clean System(Tapered & Straight) & SAVE_ e-Clean System(Tapered)_ I-Fix System
Ⅴ. Cleanlant Surgical KIT _ Features of Surgical Kit_ Combined KIT_ Straight KIT_ SAVE KIT_ I-Fix KIT_ PROKIT_ Surgical Tools_ SAVE Surgical Tools_ I-Fix Surgical Tools
A crystal of engineering skills witha soul Cleanlant
Cleanlant System SelectionI
08 | 09 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
10 | 11 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
“Safe”- Cleanlant - A Gift of the Top Engineering Skills
Comfortable and strong natural looking teeth manufactured
with pinpoint precision and accuracy without room for the
slightest gap. Cleanlant System has improved through inno-
vation to overcome many obstacles existing in other products
during surgery such as ensuring the range of vision and the
distance between the upper and lower teeth.
Features of Cleanlant SystemII
1. Surface Treatment
× 1,200× 5,000 × 2,000
× 500× 50 × 250
1.Surface Treatment
Using RBM Treatment, the surface of the implant is blasted using CaP powder to increase
cohesion of osseo tissue, followed by thorough cleaning of the surface. The roughness is
1.5±0.2um and the surface magnification power is about 192% after surface treatment.
2. Condition of Surface
Surface Stats
Dimensional Interactive Display
Ra : 1.70umRq : 2.13umRt : 17.23um
Measurement Info
Magnification : 19.86Measurement Mode : VSISampling : 498.41nmArray Size : 640×480
Surface Stats
Ra : 1.67umRq : 2.08umRt : 16.86um
Surface Stats
Magnification : 19.86Measurement Mode : VSISampling : 498.41nmArray Size : 640×480
14 | 15 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Cleaning Two Times Using Neutral Detergent
Neutral Detergent Cleaning 1
2. Cleaning System
Removal of Cutting Oil Stuck to the Productfrom the CNC Manufacturing Process
Inspection of Washed Product After theNeutral Detergent Cleaning
Protein Removal
The Result of the EDS Analysis of theElements
Drying of Product after Cleaning
Cleaning Three Times using Distilled WaterCleaning Three Times Using Neutral Detergent
Cutting Oil Removal
Product Inspection
Acid Cleaning
Final Inspection Drying
Cleaning Using Distilled WaterCleaning using Neutral Detergent 2
Because of the exposure of the titanium to the air, detergent and remaining cutting oil, various
organic matters are existed on the surface of the dental implant around 0.3 to 1nm. In addition,
the existing elements such as Ca, P, N, Si, S and Cl can be identified even though there might be
minute traces of them. The small quantities of the above elements and organic matters are not
reported to harm the human body yet. However DENTIS Company controls its washing
process to minimize any residue and proves its washing validity through testing sample of the
surface of every lot number which we produce.
3. Analysis of the Elements on the Surface
Element Wt% At%
NK 03.92 12.25
Tik 96.08 87.75
Matrix Correction ZAF
Element Wt% At%
NK 01.31 03.83
OK 05.78 14.86
PK 02.88 03.83
CaK 01.31 01.35
TiK 88.71 76.13
Matrix Correction ZAF
DENTIS
A
B
C
D
AI
N.D.
0.033
0.011
N.D.
0.065
Ca
0.052
0.181
0.244
0.274
0.156
Cu
N.D.
0.013
N.D.
0.009
0.005
Na
N.D.
N.D.
N.D.
N.D.
N.D.
P
N.D.
0.429
N.D.
0.103
N.D.
Si
0.127
0.967
0.103
0.161
0.294
Zn
N.D.
0.010
0.005
0.007
N.D.
F+
N.D.
0.02
0.01
0.05
0.01
CI+
0.04
0.14
0.18
0.39
0.14
NO₂+
N.D.
0.04
0
0.02
0.03
NO₃+
0.04
0.63
0.14
0.34
0.1
PO₄³+
N.D.
1.4
0
0.41
0
PO₄²+
0.13
1.03
0.51
0.6
0.33ICP, IC Quantitative Analysis
ElementSample
After DENTIS Eluted Fluid Group treated with L929 fibroblast for 24hours, the test result
showed that it is not effect on the growth like Media Control Group and Negative Control
Group at all.
DENTIS controls excellent clean level by developing and building DENTIS Cleaning System.
4. Analysis of the Elements on the Surface with ICP/IC
5. The Cytotoxicity Test Result
According to ISO 10993-5, the cytotoxicity test result
Final Inspection Negative Control Group
Positive Control Group DENTIS Fixture Eluted Fluid Group
16 | 17 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
1. The 3 Types of Fixture Design for Various Cases
Its products have been developed to be applied to various clinical cases and provide 3 types of
fixture, i-Clean, e-Clean and s-Clean, for parts that need esthetics and according to the condi-
tion of the bone.
2. Convenient Compatibility of Superstructure
Cleanlant is economical to use with the certain products such as Branemark, ITI, Astra, and
Swissplus implants.
3. Optimum RBM Surface Treatment
Roughness measurement of the surface is Ra: 1.5~1.8um. This measurement is the most ideal
value for osseointegration.
3. Features of Cleanlant
× 5,0001 3 4
4. i-Clean/ s-Clean Fixture is No-mount System
During surgery, existing Mount System obstructs the range of vision and the distance
between the upper and lower teeth, however DENTIS No-mount system can immediately
ensure a path during surgery and reduces operation time and attains accurate operation
with no effects by the surrounding teeth.
18 | 19 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
1. Micro-thread for Bone Loss Prevention
Cleanlant Micro-thread minimizes bone loss, bone stress and appropriate
stimulus of the cortical bone together with stable initial fixation.
2. Tapered Design and Rotating Safe Cutting Edge for Smooth Drilling
It has been designed for excellent osseointegration as well as excellent initial
fixation as it remarkably reduces excessive friction with the bone due to
uniform transmission of strength during insertion owing to safe cutting edge
that follows the direction of the rotation. The cutting edge is on the whole
body of the fixture and has tapered design and double thread.
3. e-Clean Mount for Impression and Abutment
e-Clean Mount is economical and makes it simple for dental prosthetics.
Mount could be used as Impression Coping (Transfer) and final abutment,
after insertion.
3-1. Features of Tapered Body Implant
× 501 2 3
1. Designed for Smooth Insertion in Various Bone Densities.
Cleanlant straight type is designed for smooth insertion in various bone densities, allowing not
giving excessive bone stress and secure insertion.
2. Design for Excellent Initial Stability
Double thread design provides the reducing insertion time and increasing the initial stability.
When placing the implant, it helps self-tapping and allowing the space for the bone, increas-
ing the initial stability.
Apex 5°tapered design guiding for placing implant at drilling hole.
3-2. Features of Straight body implant
If a necessary initial fixation is not obtained because of the loss of a wide fixture or the widening
of the alveolar bone during surgery. By using SAVE, implantation can be performed immediate-
ly, and sufficient initial fixation can be obtained, allowing the successful completion of the
implantation.
1. Platform Switching
Further loss of the alveolar bone is not allowed. It reduces alveolar bone loss to the maximum in
the fixture shoulder region using Platform Switching Process.
2. Convenient Compatibility of Superstructure
It is economical to use with Cleanlant superstructure so there is no need for additional SAVE
Abutment System.
3. SAVE System
3-3. Features of SAVE implant
5˚ 5˚
O-Ring Type Angled Type
Suitable for narrow space in themaxillary and mandibular anteriorteeth
One-body type design providesmaximum strength for mastication
Total gingival height is collar (1.3mm or 3.3mm) + cuff height (0.7)
Suitable for the edentulouspatients
Creating fast and simpletemporary prosthesis
Specialized 2 pieces-designreinforce safe fixation
Abutments are divided intoCemented and Angled for variouscases and placement direction
Take fast, convenient impressionswith 2 types of impression copingin narrow space
Collar
Post Type
Post Type O-Ring Type Angled Type
2㎜4㎜
1.5㎜3.5㎜
1.3㎜3.3㎜
Cemented Abutment Angled Abutment
Cuff
Angled Type
0.7㎜ 0.7㎜
Angled Type - Collar+Cuff
Usable with regular size of retainer furthermore o-ring cap is availableCollar heights are 1.5mm and 3.5mm
O-Ring Type Collar
0.7㎜
15°
1.3㎜
Neck design helps to make fast healing time
Post type Neck design
1.5 / 3.5㎜
2.7㎜
2㎜(Driver connection area)
O-Ring Cap O-Ring
1. Three Types of Fixture
3-4. Features of I-Fix implant
20 | 21 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
1. The fixation is strong and safe between screw and fixturewith over 4 and half pitch screw connection
2. Morse taper connection between the implant and theabutment offers the friction locking and sealing
3. Torque recommendation : 30-35Ncm
Mount is used as healing abutment and cover screw after placement.
Free, easy milling and prosthesis work as the application ofDENTIS regular free abutmentGroove in the abutment body - Strong fixation with cement
- 0.9 Hex Driver -
2. 2 pieces-type with Maximum Strength
3. Another Function of Angled Type Mount
4. Angled Type - Free Abutment
in the case of interference fromneighboring teeth.
Height 18mm, 23mm impression coping
18mm and 23mm impression copings provide convenient impression-taking in narrow interproximal space.
One driver fits all 3types of screw
Three types of impression coping available in variouspick-up impression cases
18㎜ 23㎜
Height
Impression Coping
18㎜12㎜ 23㎜
12㎜
Post typeMachine Driver
LongShort
O-Ring type Angle type
5. For use where Narrow Interproximal Space
6. Easy Surgical Tool
22 | 23 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
“Simple and Convenient”SurgeryCleanlant
Cleanlant system that is upgraded day by day helps accurate
and safe implant surgery. DENTIS patented engineering
skills induces smooth insertion, does not induce extreme to
the patient, is greatly convenient, and surgery can be per-
formed fast and simply.
Uses of Cleanlant Abutment System
III
1. Uses of i-Clean Abutment System
1) Uses of Solid Abutment
Generally, it is used when getting the abutment Level impression of i-Clean type and can be used
in all cases, single unit and multi unit, to make cemented type prosthesis.
2) Uses of Excellent Abutment
In molar cases, when abutment is smaller than the size of the prosthesis, it increases the size of the
normal solid abutment, and possesses stability.
3) Uses of InOcta Abutment
It is used for making SCRP dental prosthesis and in choosing cuff of the abutment to suit the thick-
ness of the gingiva when part of the implant shoulder is being drilled under the gums and getting
an impression in the fixture level.
4) Uses of SyncOcta Abutment
It can be used in all cases, single unit and multi unit and getting an impression in the fixture level.
As all stages of dental prosthesis production is possible in the lab, chair time is reduced. This is
Cemented Type and is possible to make SCRP dental prosthesis.
5) Uses of Gold ULCA Abutment
It is used when the opposing of surfaces of the teeth of the two jawbones does not come into con-
tact and the dentist makes screw type prosthesis.
6) Uses of Angled Abutment
It is prepared in 15 and 25 degrees and can be used in cases to compensate for the angle and the
insertion path is not good.
7) Uses of Octa Abutment
It is used when prosthesis requires screw type, or cases of multiple unit that does not have a good
path.
8) Uses of O-Ring Abutment
It is used for over denture.
26 | 27 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
2. Uses of s-Clean Abutment System
1) Uses of Sole Abutment
Generally, it is used when getting the Abutment Level impression of s-Clean type and can be used
in all cases, single unit and multi unit, to make cemented type prosthesis.
2) Uses of Couple Abutment
It can be used in all cases, single unit and multi unit and getting an impression in the fixture and
abutment level. As all stages of dental prosthesis production is possible in the lab, chair time is
reduced. This is cemented type and is possible to make SCRP dental prosthesis.
3) Uses of Gold UCLA Abutment
It is used when the opposing of surfaces of the teeth of the two jawbones does not come into con-
tact and the dentist makes screw type prosthesis.
4) Uses of Angled Abutment
It is prepared in 15 and 25 degrees and can be used in cases to compensate for the angle and the
insertion path is not good.
5) O-Ring Abutment
It is used for over denture.
28 | 29 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
3. Uses of e-Clean Abutment System
1) Uses of Cemented Abutment
Generally, it is used when making dental prosthesis of the cemented type.
2) Uses of Estheticone Abutment
It is used when prosthesis requires screw type, or cases of multiple unit that does not have a good
path.
3) Uses of Angled Abutment
It is prepared in 15 and 25 degrees and can be used in cases to compensate for the angle and the
insertion path is not good.
4) Uses of Gold UCLA Abutment
It is used when the opposing of surfaces of the teeth of the two jawbones does not come into con-
tact and the dentist makes screw type prosthesis.
5) O-Ring Abutment
It is used for over denture.
Natural-looking teeth like its partof your body - Cleanlant
RBM Surface Treatment minimizes danger of contamination
accounted to foreign matter. Produce teeth shaped like the
natural teeth and surpasses esthetic appreciation.
It is semi-permanent as it made of superior materials.
Cleanlant System Flow
IV
i-Clean System Flow
“Convenient”No-mount System
During surgery, existing Mount System obstructs the range of vision and
the distance between the upper and lower teeth, however DENTIS No-
mount system can immediately ensure a path during surgery and
reduces operation time and attains accurate operation with no effects
from the surrounding teeth.
Octa
Octa Connection prosthesis is compatible with superstructures of ITI
and Swissplus.
Tapered design
Root Form Design achieved superb initial fixation strength also in places
where condition of the bone is not good, makes an easy and stable
surgery possible and reduces surgery time.
Micro-Thread for Bone Loss Prevention
It prevents water absorption of the cortex due to bacterial infection and
minimizes bone loss, breaking due to i-Clean stress and stimulus of the
cortical bone with stable initial fixation strength and wedges in thin cor-
tex as well.
RBM Surface Treatment (1.5±0.2um)
It maximizes osseointegration.
Safe cutting edge
It minimizes resistance of the bone during insertion of the implant and
functions to provide safe and smooth insertion.
Self-tapping Groove
It helps self-tapping during the insertion of the implant and at the same
time be the space for bone chips. In addition, boost fixation strength
after insertion.
2.0mm Machined collar
× 5,000
Wide
PlatformDiameter
Length Code
ø4.8
8.0mm
10.0mm
12.0mm
14.0mm
DIFWR4808
DIFWR4810
DIFWR4812
DIFWR4814
ImplantDiameter
ø4.8
Regular
PlatformDiameter
Length Code
ø4.8
8.0mm
10.0mm
12.0mm
14.0mm
DIFR4308
DIFR4310
DIFR4312
DIFR4314
ImplantDiameter
ø4.3
Mini
PlatformDiameter
Length Code
ø4.8
8.0mm
10.0mm
12.0mm
14.0mm
DIFM3708
DIFM3710
DIFM3712
DIFM3714
ImplantDiameter
ø3.7
System
32 | 33 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
ø4.8
2.0㎜
ø3.0
ø3.7
L
ø4.8
2.0㎜
ø3.6
ø4.3
L
ø4.8
ø4.8
ø4.8
ø4.8
2.0㎜
ø4.1
ø4.8
L
i-Clean System Flow
Octa
Octa connection prosthesis is compatible with super-
structure of ITI and Swissplus.
0.9mm
4˚
R0.65
0.1mm
Designed for Smooth Insertion in Various Bone Densities
Cleanlant straight type is designed for smooth insertion in various bone den-
sities, allowing not giving excessive bone stress and secure insertion.
Convenient Compatibility of Superstructure
Cleanlant is economical to use with the certain products such
as ITI and Swissplus implants.
“Convenient”No-mount System
During surgery, existing Mount System obstructs the
range of vision and the distance between the upper and
lower teeth, however, DENTIS No-mount System can
immediately ensure a path during surgery and reduces
operation time and attains accurate operation with no
effects from the surrounding teeth.
RBM Surface Treatment (1.5±0.2um)
It maximizes osseointegration.
Design for Excellent initial stability
Double thread design provides the reducing insertion
time and increasing the initial stability. When placing the
implant, it helps self-tapping and allowing the space for
the bone, increasing the initial stability. Apex 5°tapered
design guiding for placing implant at drilling hole.5˚ 5˚
ø4.8
0.65㎜
2㎜
ø4.1
L
PlatformDiameter
Collar Length
ø4.8
2mm
2mm
2mm
2mm
8mm
10mm
12mm
14mm
Code
DISF4108L
DISF4110L
DISF4112L
DISF4114L
ImplantDiameter
ø4.1
PlatformDiameter
Collar Length
ø4.8
2mm
2mm
2mm
2mm
8mm
10mm
12mm
14mm
Code
DISF4808L
DISF4810L
DISF4812L
DISF4814L
ImplantDiameter
ø4.8
34 | 35 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
ø4.8
0.65㎜
2㎜
ø4.8
L
System
Internal Fixture
SAVE Internal System Flow
Safe Cutting Edge/ Tapered Design
It has been designed for excellent osseointegration as well as excellent
initial fixation as it remarkably reduces excessive friction with the bone
due to uniform transmission of strength during insertion.
Optimum RBM Surface Treatment
Roughness measurement of the surface is
Ra: 1.5±0.2um. This measurement is the
most ideal value for osseointegration.
Micro-thread for Bone Loss Prevention
Micro-thread minimizes bone loss, break-
ing due to internal stress and appropriate
stimulus of the cortical bone together with
stable initial fixation.
“Convenient”No-mount System
During surgery, existing Mount System obstructs the range of vision and
the distance between the upper and lower teeth, however DENTIS No-
mount system can immediately ensure a path during surgery and
reduces operation time and attains accurate operation with no effects by
the surrounding teeth.
× 50
× 5,000
36 | 37 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
ø5.5 SAVE Internal Fixture Size
ø6.0 SAVE Internal Fixture Size
ø6.0
10.0㎜
0.65㎜
ø5.3
2.0㎜
ø6.0
ø5.5
ø6.0
10.0㎜
0.65㎜
2.0㎜
ø4.8
PlatformDiameter
Length Code
ø6.0
7.0mm
8.0mm
10.0mm
12.0mm
DIFS5507
DIFS5508
DIFS5510
DIFS5512
ImplantDiameter
ø5.5
PlatformDiameter
Length Code
ø6.0
7.0mm
8.0mm
10.0mm
12.0mm
DIFS6007
DIFS6008
DIFS6010
DIFS6012
ImplantDiameter
ø6.0
Internal System
Solid AbutmentSolid Abutment Driver Excellent Solid Abutment DriverExcellent Solid Abutment
Prosthetic Flow Diagrams for i-Clean
Solid System
Shoulder Analog & Pin
Lab Analog
Plasitc Coping
Healing Abutment 1.2 Hex Driver
i-Clean
Cover Screw
BridgeSingle
Impression Caps Positioning Cylinder
LengthPlatform Diameter Code No.DISA40DISA55DISA70
4mm5.5mm7mm
Ø4.8
Solid Abutment
Solid Abutment System
38 | 39 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
L: 4, 5.5, 7m
Closing Screw
Healing Abutment
Cover Screw
CuffPlatform Diameter Code No.DIH30DIH40DIH55
DIHS30DIHS40DIHS55
3mm4mm
5.5mm
3mm4mm
5.5mm
Ø4.8
Ø6.0
CuffPlatform Diameter Code No.DICS1
DISCS60
2mm
2mm
Ø4.8
Ø6.0
Ø6.0 : SAVE Only
Ø6.0 : SAVE Only
CuffPlatform Diameter Code No.DICS30mmØ4.8
2mm
Cuff: 3, 4, 5.5mm
TypePlatform Diameter Code No.DISIPCRØ4.8
Positioning Cylinder
LengthPlatform Diameter Code No.DIESA40DIESA55DIESA70
4mm5.5mm7mm
Ø4.8
TypePlatform Diameter Code No.DISICRØ4.8
Impression Cap
Excellent Solid Abutment
L: 4, 5.5, 7m
Platform Diameter Code No.DIISARDISAPR
Ø4.8
TypePlatform Diameter Code No.DISPSDISPB
SingleBridge
Ø4.8
Plasitc Coping
Shoulder Analog & Pin
Bridge
Single
Solid Abutment System
40 | 41 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
LengthPlatform Diameter Code No.DISLA40DISLA55DISLA70
4mm5.5mm7mm
Ø4.8
Lab Analog
L: 4, 5.5,7mm
Prosthetic Flow Diagrams for i-Clean
InOcta System
Impression Coping(Pick-up) Impression Coping(Transfer)
Lab Analog
Healing Abutment 1.2 Hex Driver
i-Clean
Cover Screw
Angled Abutment SynOcta AbutmentInOcta Abutment Gold UCLA
15。 25。N-OctaOcta
Free Abutment
N-OctaOcta N-OctaOcta N-OctaOcta
TypePlatform Diameter Code No.Impression Coping
DIPIR
DITIRDITIN
DIPIS60
Pick-Up
Transfer
Pick-Up
Pick-Up
Transfer
Ø4.8
Ø6.0
InOcta Abutment System
42 | 43 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Platform Diameter Code No.DILA
DILAS
Ø4.8
Ø6.0
Lab Analog
Ø6.0 : SAVE Only
Ø6.0 : SAVE Only
CuffTypePlatform Diameter Code No.DICO10DICO20DICO30DICO40
DICO10NDICO20NDICO30NDICO40N
1mm2mm3mm4mm
1mm2mm3mm4mm
Octa
N-Octa
Ø4.8Ø4.8
InOcta Abutment
TypePlatform Diameter Code No.DIAA15DIAA25
15。25。
Ø4.8
Angled Abutment
15。
25。
Octa
Octa
6mm
Cuff:1, 2, 3, 4mm
N-Octa
N-Octa
Free Abutment Platform Diameter Code No.DIFAODIFAN
OctaN-Octa
Type
DICOS10DICOS20DICOS30DICOS40
DICOS10NDICOS20NDICOS30NDICOS40N
1mm2mm3mm4mm
1mm2mm3mm4mm
Octa
N-Octa
Ø6.0
Ø6.0 : SAVE Only
SynOcta Abutment
Temporary Abutment
Gold UCLA
InOcta Abutment System
TypePlatform Diameter Code No.DIGUODIGUN
OctaN-Octa
Ø4.8
TypePlatform Diameter Code No.DITA10ODITA20ODITA30ODITA40O
DITA10NDITA20NDITA30NDITA40N
Octa
N-Octa
Cuff1mm2mm3mm4mm
1mm2mm3mm4mm
Ø4.8
TypePlatform Diameter Code No.DISOADISOAN
OctaN-Octa
Ø4.8
N-Octa
Octa
Octa N-Octa
Octa
N-Octa
44 | 45 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Cuff:1, 2, 3, 4mm
Cuff:1, 2, 3, 4mm
Prosthetic Flow Diagrams for i-Clean
Octa System
Impression Coping(Pick-up)
Octa Lab Analog
Healing Abutment
i-Clean
Cover Screw
Octa Abutment
Gold Cylinder Plastic Cylinder
N-HexHex N-OctaOcta
Octa Abutment Driver
1.2 Hex Driver
Impression Coping(Transfer)
Octa Abutment System
Platform Diameter Code No.DIOHCØ4.8
Platform Diameter Code No.DIOAØ4.8
Octa Abutment
Impression Coping
Octa Healing Cap
TypePlatform Diameter Code No.DIOIODIOIN
DIOTIDITIN
Pick-Up
Pick-Up
Transfer
Transfer
Ø4.8
46 | 47 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Platform Diameter Code No.DIOLAØ4.8
Lab Analog
Gold Cylinder TypePlatform Diameter Code No.DIOGCODIOGCN
OctaN-Octa
Ø4.8
Octa
N-Octa
Octa Abutment System
Plastic Cylinder TypePlatform Diameter Code No.DIOPODIOPN
OctaN-Octa
Ø4.8
N-Octa
Octa
48 | 49 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Prosthetic Flow Diagrams for i-Clean
O-Ring System
O-Ring AbutmentO-Ring Abutment Driver
O-Ring Lab Analog
Healing Abutment
i-Clean
Cover Screw
O-Ring O-Ring Retainer
1.2 Hex Driver
O-Ring Abutment System
Code No.DOLA
Code No.DOR
O-Ring Abutment
O-Ring Retainer
O-Ring Lab Analog
Code No.ORING
O-Ring
CuffAbutment Diameter Code No.DIORA00DIORA20DIORA40
0mm2mm4mm
Ø3.5
Cuff: 0, 2, 4mm
50 | 51 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
s-Clean System Flow
“Convenient”No-mount System
During surgery, existing Mount System obstructs the range of vision and
the distance between the upper and lower teeth, however DENTIS No-
mount system can immediately ensure a path during surgery and
reduces operation time and attains accurate operation with no effects
from the surrounding teeth.
Hex
Hex Connection prosthesis is compatible with the superstructure with
products of Astra.
Tapered design
Root Form Design achieved superb initial fixation strength also in places
where condition of the bone is not good, makes an easy and stable
surgery possible and reduces surgery time.
Micro-Thread for Bone Loss Prevention
It prevents water absorption of the cortex due to bacterial infection and
minimizes bone loss, breaking due to i-Clean stress and stimulus of the
cortical bone with stable initial fixation strength and wedges in thin cor-
tex as well.
RBM Surface Treatment (1.5±0.2um)
It maximizes osseointegration.
Safe cutting edge
It minimizes resistance of the bone during insertion of the implant and
functions to provide safe and smooth insertion.
Self-tapping Groove
It helps self-tapping during the insertion of the implant and at the same
time be the space for bone chips. In addition, boost fixation strength
after insertion.
× 5,000
Wide
PlatformDiameter
Length Code
ø4.8
8.0mm
10.0mm
12.0mm
14.0mm
DSFW4808
DSFW4810
DSFW4812
DSFW4814
ImplantDiameter
ø4.8
Regular
PlatformDiameter
Length Code
ø4.3
8.0mm
10.0mm
12.0mm
14.0mm
DSFR4308
DSFR4310
DSFR4312
DSFR4314
ImplantDiameter
ø4.3
Mini
PlatformDiameter
Length Code
ø3.7
8.0mm
10.0mm
12.0mm
14.0mm
DSFM3708
DSFM3710
DSFM3712
DSFM3714
ImplantDiameter
ø3.7
52 | 53 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
ø3.7
0.4㎜
ø3.0
ø3.7
ø4.3
ø4.8
ø3.7
L
ø4.3
0.4㎜
ø3.6
ø4.3
L
ø4.8
0.4㎜
ø4.1
ø4.8
L
System
s-Clean System Flow
0.9mm
4˚
R0.65
0.1mm
5˚ 5˚
Hex
Hex Connection prosthesis is compatible with the
superstructure with products of Astra.
Designed for Smooth Insertion in Various Bone Densities
Cleanlant straight is designed for smooth insertion in various bone densities,
allowing not giving excessive bone stress and secure insertion.
Convenient Compatibility of Superstructure
Cleanlant is economical to use with the certain products such
as Astra implants.
“Convenient”No-mount System
During surgery, existing Mount System obstructs the
range of vision and the distance between the upper and
lower teeth, however, DENTIS No-mount System can
immediately ensure a path during surgery and reduces
operation time and attains accurate operation with no
effects from the surrounding teeth.
RBM Surface Treatment (1.5±0.2um)
It maximizes osseointegration.
Design for Excellent initial stability
Double thread design provides the reducing insertion
time and increasing the initial stability. When placing the
implant, it helps self-tapping and allowing the space for
the bone, increasing the initial stability. Apex 5°tapered
design guiding for placing implant at drilling hole.
ø4.1
L
54 | 55 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
ø4.8
L
Length Code
8mm
10mm
12mm
14mm
DSSF4108
DSSF4110
DSSF4112
DSSF4114
ImplantDiameter
ø4.8
Length Code
8mm
10mm
12mm
14mm
DSSF4808
DSSF4810
DSSF4812
DSSF4814
ImplantDiameter
ø4.8
System
Submerged Fixture
SAVE Submerged System Flow
Safe Cutting Edge/ Tapered Design
It has been designed for excellent osseointegration as well as excellent
initial fixation as it remarkably reduces excessive friction with the bone
due to uniform transmission of strength during insertion.
Optimum RBM Surface Treatment
Roughness measurement of the surface is Ra:
1.5±0.2um. This measurement is the most ideal
value for osseointegration.
Micro-thread for Bone Loss Prevention
Cleanlant Micro-thread minimizes bone loss, breaking due to internal
stress and appropriate stimulus of the cortical bone together with stable
initial fixation.
Platform Switching System
Further loss of the alveolar bone is not allowed. It
reduces alveolar bone loss to the maximum in the
Fixture Shoulder region using Platform Switching
Process.
“Convenient”No-mount System
During surgery, existing Mount System obstructs the range of vision and
the distance between the upper and lower teeth, however DENTIS No-
mount system can immediately ensure a path during surgery and
reduces operation time and attains accurate operation with no effects by
the surrounding teeth.
Convenient Compatibility of Superstructure
It is economical to use with Cleanlant superstructure so there is no need
for additional SAVE Abutment System.
× 5,000
56 | 57 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
ø5.5 SAVE Submerged Fixture Size
ø6.0 SAVE Submerged Fixture Size
ø5.5
10.0㎜
0.4㎜
ø4.8
ø5.5
ø6.0
ø6.0
10.0㎜
0.4㎜
ø5.3
PlatformDiameter
Length Code
ø5.5
7.0mm
8.0mm
10.0mm
12.0mm
DSFS5507
DSFS5508
DSFS5510
DSFS5512
ImplantDiameter
ø5.5
PlatformDiameter
Length Code
ø6.0
7.0mm
8.0mm
10.0mm
12.0mm
DSFS6007
DSFS6008
DSFS6010
DSFS6012
ImplantDiameter
ø6.0
Submerged System
Prosthetic Flow Diagrams for s-Clean
Sole System
BridgeSingle
Impression Cap
Lab Analog
Healing Abutment 1.25 Hex Driver
s-Clean
Cover Screw
Sole Abutment 1.25 Hex Driver
Plastic Coping
Cover Screw
2mm
ø4.5, 5.5, 6.5
Cuff: 1.0, 1.5, 2.0,2.5,3.5, 4.5, 5.5mm
Sole Abutment System
Abutment Diameter Code No.DSCSM
Healing Abutment CuffAbutment Diameter Code No.DSH4510DSH4515DSH4520DSH4525DSH4535DSH4545DSH4555
DSH5510DSH5515DSH5520DSH5525DSH5535DSH5545DSH5555
DSH6515DSH6520DSH6525DSH6535DSH6545DSH6555
1.0mm1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
1.0mm1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
Ø4.5
Ø5.5
Ø6.5
58 | 59 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Sole Abutment
Abutment Diameter Code No.DSIPC45
DSIPC55
DSIPC65
Ø4.5
Ø5.5
Ø6.5
Impression Cap
LengthCuffAbutment Diameter Code No.5.5mm
5.5mm
5.5mm
Cuff: 0.8,1.5,2.0, 2.5, 3.5, 4.5, 5.5mm
5.5mm
DSSA4510DSSA4515DSSA4520DSSA4525DSSA4535DSSA4545DSSA4555
DSSA5510DSSA5515DSSA5520DSSA5525DSSA5535DSSA5545DSSA5555
DSSA6515DSSA6520DSSA6525DSSA6535DSSA6545DSSA6555
1.0mm1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
1.0mm1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
Ø4.5
Ø5.5
Ø6.5
Lab Analog
Sole Abutment System
Abutment Diameter Code No.DSSLA45
DSSLA55
DSSLA65
Ø4.5
Ø5.5
Ø6.5
Plastic Coping TypeAbutment Diameter Code No.DSSP45SDSSP45B
DSSP55SDSSP55B
DSSP65SDSSP65B
SingleBridge
SingleBridge
SingleBridge
Ø4.5
Ø5.5
Ø6.5
Single
Bridge
60 | 61 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Prosthetic Flow Diagrams for s-Clean
Couple System
N-HexHex Hex N-Hex25。15。
Healing Abutment
s-Clean
Cover Screw
Couple Abutment
N-HexHex
Free Abutment Gold UCLA Abutment
1.25 Hex Driver
Impression Coping(Pick-up)
Lab Analog
Angled Abutment
Hex N-Hex
Impression Coping(Transfer)
Hex N-Hex
Impression Coping
N-Hex
Hex
N-Hex
Hex
Couple Type Abutment System
LengthAbutment Diameter Code No.DSIH45LDSIH45S
DSIN45LDSIN45S
DSIH55LDSIH55S
DSIN55LDSIN55S
DSIH65LDSIH65S
DSIN65LDSIN65S
LongShort
LongShort
LongShort
LongShort
LongShort
LongShort
Hex
N-Hex
Hex
N-Hex
Hex
N-Hex
TypePick-Up
Pick-Up
Pick-Up
Pick-Up
Transfer
Ø4.5
Ø5.5
Ø6.5
LengthAbutment Diameter Code No.DSITH45LDSITH45S
DSITN45LDSITN45S
DSITH55LDSITH55S
DSITN55LDSITN55S
DSITH65LDSITH65S
DSITN65LDSITN65S
LongShort
LongShort
LongShort
LongShort
LongShort
LongShort
Hex
N-Hex
Hex
N-Hex
Hex
N-Hex
TypeTransfer
Transfer
Transfer
Ø4.5
Ø5.5
Ø6.5
62 | 63 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Impression Coping
Ø4.5(Free Abutment Only)
Ø5.5(Free Abutment Only)
Healing Abutment Abutment Diameter Code No.DSFH4525DSFH4545
DSFH5525DSFH5545
0.8mm
0.8mm
Cuff
2.5mm
ø4.5
4.5mm
ø4.5
2.5mm
ø5.5
4.5mm
ø5.5
Couple Abutment LengthCuffAbutment Diameter Code No.DSCA4510HDSCA4515HDSCA4520HDSCA4525HDSCA4535HDSCA4545HDSCA4555H
DSCA5510HDSCA5515HDSCA5520HDSCA5525HDSCA5535HDSCA5545HDSCA5555H
DSCA6515HDSCA6520HDSCA6525HDSCA6535HDSCA6545HDSCA6555H
DSCA4510NDSCA4515NDSCA4520NDSCA4525NDSCA4535NDSCA4545NDSCA4555N
DSCA5510NDSCA5515NDSCA5520NDSCA5525NDSCA5535NDSCA5545NDSCA5555N
DSCA6515NDSCA6520NDSCA6525NDSCA6535NDSCA6545NDSCA6555N
5.5mm
5.5mm
5.5mm
5.5mm
5.5mm
5.5mm
TypeHex
N-Hex
1.0mm1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
1.0mm1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
1.0mm1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
1.0mm1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
Ø4.5
Ø5.5
Ø6.5
Ø4.5
Ø5.5
Ø6.5
Ø4.5Ø5.5
Ø4.5Ø5.5
N-Hex
N-Hex
Hex
Hex
Lab Analog Code No.DSCLA
Free Abutment Abutment Diameter Code No.DSFA45HDSFA55H
DSFA45NDSFA55N
Hex
N-Hex
L
Cuff
Type
Couple Abutment
Angled Abutment
Couple Type Abutment System
Gold UCLA
LengthCuffAbutment Diameter Code No.DSAA45152DSAA45154
DSAA45252DSAA45254
DSAA55152DSAA55154
DSAA55252DSAA55254
DSAA65152DSAA65154
DSAA65252DSAA65254
2mm4mm
2mm4mm
2mm4mm
2mm4mm
2mm4mm
2mm4mm
15。
25。
15。
25。
15。
25。
Ø4.5
Ø5.5
Ø6.5
25。
15。
TypeAbutment Diameter Code No.DSGCH
DSGCN
Hex
N-Hex
Hex N-Hex64 | 65 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
N-Hex
Hex
L
Cuff
LengthCuffAbutment Diameter Code No.DSCA4510H7DSCA4515H7DSCA4520H7DSCA4525H7DSCA4535H7DSCA4545H7DSCA4555H7
DSCA5510H7DSCA5515H7DSCA5520H7DSCA5525H7DSCA5535H7DSCA5545H7DSCA5555H7
DSCA6515H7DSCA6520H7DSCA6525H7DSCA6535H7DSCA6545H7DSCA6555H7
DSCA4510N7DSCA4515N7DSCA4520N7DSCA4525N7DSCA4535N7DSCA4545N7DSCA4555N7
DSCA5510N7DSCA5515N7DSCA5520N7DSCA5525N7DSCA5535N7DSCA5545N7DSCA5555N7
DSCA6515N7DSCA6520N7DSCA6525N7DSCA6535N7DSCA6545N7DSCA6555N7
7mm
7mm
7mm
7mm
7mm
7mm
TypeHex
N-Hex
1.0mm1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
1.0mm1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
1.0mm1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
1.0mm1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
1.5mm2.0mm2.5mm3.5mm4.5mm5.5mm
Ø4.5
Ø5.5
Ø6.5
Ø4.5
Ø5.5
Ø6.5
Prosthetic Flow Diagrams for s-Clean
Sub Octa System
Impression Coping(Pick-up)
Octa Lab Analog
Healing Abutment
s-Clean
Cover Screw
Sub Octa Abutment
Gold Cylinder Plastic Cylinder
N-HexHex N-OctaOcta
Octa Abutment Driver
1.25 Hex Driver
Impression Coping(Transfer)
Octa Abutment System
Abutment Diameter Code No.DIOHCØ4.8
Abutment Diameter Code No.DSOA480DSOA481DSOA482DSOA483DSOA484DSOA485
Ø4.8
Sub Octa Abutment
Impression Coping
Octa Healing Cap
TypeAbutment Diameter Code No.DIOIODIOIN
DIOTI
Pick-Up
Pick-Up
Transfer
Transfer
Ø4.8
66 | 67 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Cuff1.0mm1.5mm2.5mm3.5mm4.5mm5.5mm
Abutment Diameter Code No.DIOLAØ4.8
Lab Analog
Gold Cylinder TypeAbutment Diameter Code No.DIOGCODIOGCN
OctaN-Octa
Ø4.8
Octa
N-Octa
Octa Abutment System
Plastic Cylinder TypeAbutment Diameter Code No.DIOPODIOPN
OctaN-Octa
Ø4.8
N-Octa
Octa
68 | 69 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Prosthetic Flow Diagrams for s-Clean
O-Ring System
O-Ring AbutmentO-Ring Abutment Driver
O-Ring Lab Analog
Healing Abutment
s-Clean
Cover Screw
O-Ring O-Ring Retainer
1.25 Hex Driver
O-Ring Abutment
Cuff: 0.5, 2, 4mm
O-Ring Abutment System
Code No.DOLA
Code No.DOR
O-Ring Retainer
O-Ring Lab Analog
Code No.ORING
O-Ring
CuffAbutment Diameter Code No.DSORA00DSORA20DSORA40
0.5mm2mm4mm
Ø3.4Ø4.5Ø4.5
70 | 71 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
e-Clean System Flow
Fixture Mount can be used for Imperssion Coping and Free Abutment.
Fixture mount is economical and makes it simple for dental prosthetics.
Mount could be used as transfer type of impression coping and final
abutment after inserted fixture.
Tapered design
Root Form Design achieved superb initial fixation strength also in places
where condition of the bone is not good, makes an easy and stable
surgery possible and reduces surgery time.
Micro-Thread for Bone Loss Prevention
It prevents water absorption of the cortex due to bacterial infection and
minimizes bone loss, breaking due to internal stress and stimulus of the
cortical bone with stable initial fixation strength and wedges in thin cor-
tex as well.
Safe cutting edge
It minimizes resistance of the bone during insertion of the implant and
functions to provide safe and smooth insertion.
RBM Surface Treatment (1.5±0.2um)
It maximizes osseointegration.
× 5,000
× 50
Wide
PlatformDiameter
Length Code
ø5.1
8.0mm
10.0mm
12.0mm
14.0mm
DEFW5108
DEFW5110
DEFW5112
DEFW5114
ImplantDiameter
ø5.1
Regular
PlatformDiameter
Length Code
ø4.1
8.0mm
10.0mm
12.0mm
14.0mm
DEFR4108
DEFR4110
DEFR4112
DEFR4114
ImplantDiameter
ø4.1
Mini
PlatformDiameter
Length Code
ø3.5
8.0mm
10.0mm
12.0mm
14.0mm
DEFM3508
DEFM3510
DEFM3512
DEFM3514
ImplantDiameter
ø3.5
72 | 73 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
ø3.5
0.7㎜
ø2.8
ø2.4
ø3.5
ø4.1
ø5.1
L
ø4.1
0.7㎜
ø3.4
ø2.7
L
ø5.1
0.7㎜
ø4.4
ø3.4
L
System
Prosthetic Flow Diagrams for e-Clean
Cemented System
Healing Abutment 1.2 Hex Driver
e-Clean
Cover Screw
Impression Coping(Transfer)Impression Coping(Pick-up)
Angled Abut. Gold UCLACemented Abut. Plastic UCLA
15。 25。N-HexHex N-Hex
N-Hex
Hex
Hex
N-HexHex
Lab Analog
Mount
Cuff: 2, 3, 4, 5.5, 7mm
6.5mm
Cemented Abutment System
Healing Abutment
Mount Platform Diameter Code No.DEFMM
DEFMR
DEFMW
Mini
Regular
Wide
Short Mount Platform Diameter Code No.DEFMSM
DEFMSR
DEFMSW
Mini
Regular
Wide
Cover Screw Platform Diameter Code No.DECSM
DECSR
DECSW
Mini
Regular
Wide
CuffPlatform Diameter Code No.DEHM420DEHM430DEHM440DEHM455DEHM470
DEHR520DEHR530DEHR540DEHR555DEHR570
DEHR620DEHR630DEHR640DEHR655DEHR670
DEHW620DEHW630DEHW640DEHW655DEHW670
2mm3mm4mm
5.5mm7mm
2mm3mm4mm
5.5mm7mm
2mm3mm4mm
5.5mm7mm
2mm3mm4mm
5.5mm7mm
Mini
Regular
Wide
74 | 75 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Impression Coping
Lab Analog
Cemented Abutment LengthCuffWide
DECAW616HDECAW626HDECAW636HDECAW646H
DECAW618HDECAW628HDECAW638HDECAW648H
Code No.
DECAR516HDECAR526HDECAR536HDECAR546H
DECAR518HDECAR528HDECAR538HDECAR548H
Regular6mm
8mm
MiniDECAM416HDECAM426HDECAM436HDECAM446H
DECAM418HDECAM428HDECAM438HDECAM448H
Type
Hex 1mm2mm3mm4mm
1mm2mm3mm4mm
DECAW616NDECAW626NDECAW636NDECAW646N
DECAW618NDECAW628NDECAW638NDECAW648N
DECAR516NDECAR526NDECAR536NDECAR546N
DECAR518NDECAR528NDECAR538NDECAR548N
DECAR616HDECAR626HDECAR636HDECAR646H
DECAR618HDECAR628HDECAR638HDECAR648H
DECAR616NDECAR626NDECAR636NDECAR646N
DECAR618NDECAR628NDECAR638NDECAR648N
6mm
8mm
DECAM416NDECAM426NDECAM436NDECAM446N
DECAM418NDECAM428NDECAM438NDECAM448N
N-Hex 1mm2mm3mm4mm
1mm2mm3mm4mm
Platform Diameter Code No.DETIM40HDETIM40N
DETIR50HDETIR50NDETIR60HDETIR60N
DETIW60HDETIW60N
TransferMini
Regular
Wide
Platform Diameter Code No.DELAM
DELAR
DELAW
Mini
Regular
Wide
Cuff: 1, 2, 3, 4mm
L
Hex
Hex
N-Hex
N-Hex
Impression Coping Platform Diameter Code No.DEIM40HDEIM40N
DEIR50HDEIR50NDEIR60HDEIR60N
DEIW60HDEIW60N
Pick-Up
Pick-Up
Transfer
HexN-Hex
HexN-HexHex
N-Hex
HexN-Hex
Type
Type
HexN-Hex
HexN-HexHex
N-Hex
HexN-Hex
Mini
Regular
Wide
LengthCuffWide
DEAAW6215DEAAW6415
DEAAW6225DEAAW6425
Platform Diameter
DEAAR6215DEAAR6415
DEAAR6225DEAAR6425
DEAAR5215DEAAR5415
DEAAR5225DEAAR5425
Regular8mm
8mm
MiniDEAAM4215DEAAM4415
DEAAM4225DEAAM4425
Type
15。
25。
2mm4mm
2mm4mm
Angled Abutment
Cemented Abutment System
Plastic UCLA
Gold UCLA
Cuff: 2, 4mm
15。
25。
N-Hex
Hex
Platform DiameterTypeWide
DEGUWH
DEGUWN
RegularDEGURH
DEGURN
MiniDEGUMH
DEGUMN
Hex
N-Hex
Platform DiameterTypeWide
DEPWH
DEPWN
RegularDEPRH
DEPRN
MiniDEPMH
DEPMN
Hex
N-Hex
N-Hex
Hex
76 | 77 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Prosthetic Flow Diagrams for e-Clean
Estheticone System
Healing Abutment 1.2 Hex Driver
e-Clean
Cover Screw
Healing CapEstheticone Abut.
Impression Coping(Transfer)Impression Coping(Pick-up)
Gold Cylinder Plastic Cylinder
N-HexHex N-HexHex
Lab Analog
Estheticone Driver
Mount
Estheticone Abutment
Estheticone Abutment System
Platform Diameter Code No.DEEHC
DEWHC
Ø4.1
Ø5.1
Impression Coping
Healing Cap
CuffPlatform Diameter Code No.DEEA10DEEA20DEEA30DEEA40
DEWA10DEWA20DEWA30DEWA40
1mm2mm3mm4mm
1mm2mm3mm4mm
Ø4.1
Ø5.1
Type
Type
Platform Diameter Code No.DEESIHDEESIN
DEWSIHDEWSIN
HexN-Hex
HexN-Hex
Pick-Up
Pick-Up
Transfer
Transfer
Ø4.1
Ø5.1
78 | 79 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Cuff:1, 2, 3, 4mm
Impression Coping Platform Diameter Code No.DEETI
DEWTI
Ø4.1
Ø5.1
Type
Gold Cylinder TypePlatform Diameter Code No.DEEGCHDEEGCN
DEWGCHDEWGCN
HexN-Hex
HexN-Hex
Ø4.1
Ø5.1
Hex
N-Hex
Lab Analog Platform Diameter Code No.DEELA
DEWLA
Ø4.1
Ø5.1
Estheticone Abutment System
Plastic Cylinder TypePlatform Diameter Code No.DEMPHDEMPN
DEWPHDEWPN
HexN-Hex
HexN-Hex
Ø4.1
Ø5.1
N-Hex
Hex
80 | 81 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Prosthetic Flow Diagrams for e-Clean
O-Ring System
O-Ring AbutmentO-Ring Abutment Driver
O-Ring Lab Analog
Healing Abutment
e-Clean
Cover Screw
O-Ring O-Ring Retainer
1.2 Hex Driver
Mount
O-Ring Abutment
Cuff:2, 4mm
O-Ring Abutment System
Code No.DOLA
Code No.DOR
O-Ring Retainer
O-Ring Lab Analog
Code No.ORING
O-Ring
CuffAbutment Diameter Code No.DEORRA20DEORRA40
DEORWA20DEORWA40
2mm4mm
2mm4mm
Ø4.1
Ø5.1
82 | 83 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Post Type Fixture
I-Fix Post Type System Flow
- Suitable for narrow space in the maxillary and
mandibular anterior teeth
- One-body type design provides maximum strength
for mastication
- Post type Neck design
Neck design helps to make fast healing timeø2.0
Length
Collar
7㎜
ø3.0
Length
Collar
7㎜
ø2.5
Length
Collar
7㎜
Collar Length CodeImplant
Diameter
2.0mm
2.0mm
2.0mm
4.0mm
4.0mm
4.0mm
10.0mm
13.0mm
16.0mm
10.0mm
13.0mm
16.0mm
DMPF2010S
DMPF2013S
DMPF2016S
DMPF2010L
DMPF2013L
DMPF2016L
ø2.0
Collar Length CodeImplant
Diameter
2.0mm
2.0mm
2.0mm
4.0mm
4.0mm
4.0mm
10.0mm
13.0mm
16.0mm
10.0mm
13.0mm
16.0mm
DMPF2510S
DMPF2513S
DMPF2516S
DMPF2510L
DMPF2513L
DMPF2516L
ø2.5
Collar Length CodeImplant
Diameter
2.0mm
2.0mm
2.0mm
4.0mm
4.0mm
4.0mm
10.0mm
13.0mm
16.0mm
10.0mm
13.0mm
16.0mm
DMPF3010S
DMPF3013S
DMPF3016S
DMPF3010L
DMPF3013L
DMPF3016L
ø3.0Lab Analog
Code
DMPL
84 | 85 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
- Suitable for the edentulous patients
- Creating fast and simple temporary prosthesis
O-Ring Type Fixture
I-Fix O-Ring Type System Flow
ø2.0
Collar
Length
2.7㎜
2㎜
ø2.5
Collar
Length
2.7㎜
2㎜
ø3.0
Collar
Length
2.7㎜
2㎜
Collar Length CodeImplant
Diameter
1.5mm
1.5mm
1.5mm
3.5mm
3.5mm
3.5mm
10.0mm
13.0mm
16.0mm
10.0mm
13.0mm
16.0mm
DMOF2010S
DMOF2013S
DMOF2016S
DMOF2010L
DMOF2013L
DMOF2016L
ø2.0
Collar Length CodeImplant
Diameter
1.5mm
1.5mm
1.5mm
3.5mm
3.5mm
3.5mm
10.0mm
13.0mm
16.0mm
10.0mm
13.0mm
16.0mm
DMOF2510S
DMOF2513S
DMOF2516S
DMOF2510L
DMOF2513L
DMOF2516L
ø2.5
Collar Length CodeImplant
Diameter
1.5mm
1.5mm
1.5mm
3.5mm
3.5mm
3.5mm
10.0mm
13.0mm
16.0mm
10.0mm
13.0mm
16.0mm
DMOF3010S
DMOF3013S
DMOF3016S
DMOF3010L
DMOF3013L
DMOF3016L
ø3.0O-ring
Code
ORING
Lab Analog
Code
DMOL
Cap
Code
DOC
Angled Type Fixture
I-Fix Angled Type System Flow
ø2.0
Length
Collar
1㎜
Collar Length CodeImplant
Diameter
1.3mm
1.3mm
1.3mm
3.3mm
3.3mm
3.3mm
10.0mm
13.0mm
16.0mm
10.0mm
13.0mm
16.0mm
DMAF2010S
DMAF2013S
DMAF2016S
DMAF2010L
DMAF2013L
DMAF2016L
ø2.0
Collar Length CodeImplant
Diameter
1.3mm
1.3mm
1.3mm
3.3mm
3.3mm
3.3mm
10.0mm
13.0mm
16.0mm
10.0mm
13.0mm
16.0mm
DMAF2510S
DMAF2513S
DMAF2516S
DMAF2510L
DMAF2513L
DMAF2516L
ø2.5
Collar Length CodeImplant
Diameter
1.3mm
1.3mm
1.3mm
3.3mm
3.3mm
3.3mm
10.0mm
13.0mm
16.0mm
10.0mm
13.0mm
16.0mm
DMAF3010S
DMAF3013S
DMAF3016S
DMAF3010L
DMAF3013L
DMAF3016L
ø3.0
ø2.5
Length
Collar
1㎜
ø3.0
Length
Collar
1㎜
- Specialized 2 pieces-design reinforce safe fixation
- Abutments are divided into Cemented and Angled for
various cases and placement direction
- Take fast, convenient impressions with 2 types of
impression coping in narrow space
86 | 87 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
12㎜
Hex
Hex
Non-Hex
Double Hex
Non-Hex
18㎜ 23㎜
0.7㎜
0.7㎜
0.7㎜
L
15°
Free Abutment
Cuff Length CodeAbutmentDiameter
0.7mm
0.7mm
11.3mm
11.3mm
DMFAH
DMFAN
ø4
ø4
Impression coping
Length Code
Cemented Abutment
Cuff Length CodeAbutmentDiameter
0.7mm
0.7mm
8.3mm
8.3mm
DMCAH
DMCAN
ø4
ø4
Angled Abutment (15°)
Cuff Length CodeAbutmentDiameter
0.7mm 9.1mm DMAA15ø4
Angled Mount Adapter
Detail Code
0.9 Hex Driver 사용 DMAMA
Lab Analog
Code
DMAL
Pick-up
DMIC12
DMIC18
DMIC23
12mm
18mm
23mm
99% Satisfaction.The remaining 1 % is for new techniques to be developed soon.
Cleanlant System absolutely improves
the defects of the existing products,
has superior compatibility,
accurate No-mount system and
strong initial fixation strength and many more.
Cleanlant Surgical KIT
V
Features of Surgical Tool
-Drill
3) Multi stopper drill
- Stopper
Basically 2mm Rotary Stopper is fitted. Attaching and detach-ing is smooth and easy. When stopper makes contact withthe bone, it stops rotating, hence does not damage the bone.
Basically Rotating Stopper is fitted. Short drill is 10mm and Long drill is 14mm. If the stopper isequiped, the short drill can be adjusted as 6mm to 8mm and the long drill can be adjusted as 10mm to12mm. It is convenient and possible to use without the stopper depending on the shape of the boneduring surgery.
The Special Features of Safe Stopper Twist Drill 1. Safe Drill Stopper The Stopper of 3-Blade Safe Tapered Twist Drill is used to prevent nerves injury from excessive drilling.
2. 3-Blade Safe Twist Drill 3-blade Safe Tapered Twist drill, produced only by DENTIS Company, has excellent cutting capability to prevent bone heating and drilling can operated at a low speed. It could easily extract bone chips and is stable for surgical operation.
3. Tapered Design3-blade Safe Tapered Twist Drill, produced only by DENTIS Company, can be used at a low drilling speed to taper into the bone and gives accurate surgical operation.
1) Cleanlant Surgical Kit
2) Stopper drill
short Long
2㎜ 3㎜ 4㎜
Tapered CCombined KIT Straight CCombined KIT SAVE KIT II--FFiixx KKIITT
8㎜
2㎜ stopper 3㎜ stopper 4㎜ stopper
7㎜6㎜
8㎜7㎜6㎜
ø5.5-S Drill
7㎜ 6㎜12㎜
2㎜ stopper 4㎜ stopper
10㎜
ø5.5-L Drill
12㎜10㎜ 10㎜
ø2.2 Twist drill ø2.8 Twist drill ø3.5 Twist drill ø3.7 Twist drillø3.5 Straight Twist drill ø4.2 Straight Twist drillø4.1 Twist drill ø4.3 Twist drill ø4.8 Twist drill ø5.1 Twist drill
90 | 91 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
4) Excellent Enhancement of W/C Coating Treatment
Tungsten Carbide Coating is 4 times stronger and easier to drill than other drills and
minimizes bone heating during drilling.
5)‘Convenient’Depth Gauge
It is easy to check the space between fixtures and the depth of Mesiodistal and the
location of buccolongual during initial drilling.
6)‘Convenient’No-mount Driver
DENTIS No-mount Driver can immediately ensure a path during surgery and
reduces operation time and attains accurate operation with no effects by the sur-
rounding teeth.
7) Multiple Tap Drill
It is manufactured for Machine and Hand use, using an adaptor that can be
attached to 3 kinds of drivers(Rachet Long, Rachet Short for Machine use and
Ratchet for Hand use)
8) Torque Rachet
Convenient fittings and accurate torque value are measured in units 15NCm,
25NCm, and 35NCm. It is be managed efficiently by simply disassembling it and can
be easily cleaned inside after operation.
Combined KIT
Ø3.7 FixtureD4 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 fixture D2-3 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø3.7 fixture D1 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø3.7 tap drill →Ø3.7 fixture
Ø4.3 FixtureD4 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 fixtureD2-3 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 drill →Ø4.3 fixture D1 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 drill →Ø4.3 tap drill →Ø4.3 fixture
Ø4.8 FixtureD4 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 drill →Ø4.8 fixtureD2-3 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 drill →Ø4.8 drill →Ø4.8 fixture D1 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 drill →Ø4.8 drill →Ø4.8 tap drill →Ø4.8 fixture
Depending on the Bone Condition
Depending on the Bone Condition
Ø3.5 FixtureD4 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 fixture D2-3 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 drill →Ø3.5 fixtureD1 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 drill →Ø3.5 tap drill →Ø3.5 fixture
Ø4.1 FixtureD4 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 drill →Ø4.1 fixtureD2-3 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 drill →Ø4.1 drill →Ø4.1 fixtureD1 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 drill →Ø4.1 drill →Ø4.1 tap drill →Ø4.1 fixture
Ø5.1 FixtureD4 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 drill →Ø4.1 drill →Ø5.1 fixtureD2-3 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 drill →Ø4.1 drill → 5.1 drill →Ø5.1 fixture D1 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 drill →Ø4.1 drill →Ø5.1 drill →Ø5.1 tap drill →Ø5.1 fixture
92 | 93 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Drilling Sequence
Drilling Sequence
/
Straight KIT
D4 D2-3 D1
D4 D2-3 D1
Ø4.1 FixtueD4 Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø4.1 fixture D2-3 Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø2.8/3.5 pilot drill →Ø3.5 straight drill →Ø4.1 fixture D1 Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø2.8/3.5 pilot drill →Ø3.5 straight drill →Ø4.1 tap drill →Ø4.1 fixture
Ø4.8 FixtueD4 Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø2.8/3.5 pilot drill →Ø3.5 straight drill →Ø4.8 fixtureD2-3 Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø2.8/3.5 pilot drill →Ø3.5 straight drill →Ø3.5/4.2 pilot drill
→Ø4.2 straight drill →Ø4.8 fixtureD1 Point drill →Ø2.2 drill →Ø2.2/2.8 pilot drill →Ø2.8 drill →Ø2.8/3.5 pilot drill →Ø3.5 straight drill →Ø3.5/4.2 pilot drill
→Ø4.2 straight drill →Ø4.8 tap drill →Ø4.8 fixture
Depending on the Bone Condition
94 | 95 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Drilling Sequence/
KIT5.5, 6.0 Fixture [Exclusive use] Surgical Kit Internal/ Submerged [Multiple Use] Stopper Drill
DrillBasically Rotating Stopper is fitted. Short drill is 8 mm andLong drill is 12mm. If the stopper is equiped, the short drillcan be adjusted as 6mm to 8mm and the long drill can beadjusted as 10mm to 12mm. It is convenient and possible touse without the stopper depending on the shape of the boneduring surgery.
StopperBasically 2mm Rotary Stopper is fitted. Attaching and detach-ing is smooth and easy. When stopper makes contact with thebone, it stops rotating, hence reduce damage to the alveolarbone.
No-mount SystemNo-mount Driver can immediately ensure a path duringsurgery and reduces operation time and attains accurateoperation with no effects by the surrounding teeth.
Ø5.5 FixtureD4 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 drill →Ø4.8 drill →Ø5.5 fixtureD2-3 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 drill →Ø4.8 drill →Ø5.5 drill →Ø5.5 fixtureD1 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 drill →Ø4.8 drill →Ø5.5 drill →Ø5.5 tap drill →Ø5.5 fixture
Ø6.0 FixtureD4 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 drill →Ø4.8 drill →Ø5.5 drill →Ø6.0 fixtureD2-3 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 drill →Ø4.8 drill →Ø5.5 drill →Ø6.0 drill →Ø6.0 fixtureD1 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 drill →Ø4.8 drill →Ø5.5 drill →Ø6.0 drill →Ø6.0 tap drill
→Ø6.0 fixture
Drilling Sequence
KITI-FIX Surgical Kit
96 | 97 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
ø2.0 Fixture Point drill →Ø1.3 straight drill →Ø2.0 fixtureø2.5 Fixture Point drill →Ø1.3 straight drill →Ø1.8 straight drill →Ø2.5 fixtureø3.0 Fixture Point drill →Ø1.3 straight drill →Ø1.8 straight drill →Ø2.3 straight drill →Ø3.0 fixture
Drilling Sequence
The function of path guide during insertion of many fixturesDiagnosis of the length and size of dental prosthesis simultaneously during insertion
PROKIT, first in the world, developed for diagnosis or use in operation,
consists of a system that can be used for getting dental impression for
prosthesis during surgery, as it provides all kinds of abutments that can
be used in i-Clean Fixture and s-Clean Fixture.
It is easy to distinguish inside of the mouth or during operation due to
color coding according to the shape and type. It can be also used in all
kinds of dental autoclave just as other operating tools.
2.8㎜
Round Bar Drill
Point drill
Code DPD
Code DRB
Surgical Tools
Drill Extension
Code DDE
98 | 99 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Position Guide
Code DPG07
2.2㎜
22.1㎜
Ø2.2
Parallel Pin
Code DPP
10㎜
2.1㎜
10㎜
Ø2.8
Ø3.96
Depth gauge
Diameter
Code
Ø2.8Ø2.2
DDG28DDG22
Pilot Drill
Ø4.2
DSPD42
Ø3.5
DSPD35
Ø2.8
DSPD28
Diameter
Code
8.9㎜
Ø2.2
Ø2.8
Ø2.8
Ø3.5
Ø3.5
Ø4.2
Twist drill
DiameterLength Ø3.5 Ø3.7 Ø4.1 Ø4.3 Ø4.8 Ø5.1
DTD3508
DTD3510
DTD3512
DTD3514
DTD3708
DTD3710
DTD3712
DTD3714
DTD4108
DTD4110
DTD4112
DTD4114
DTD4308
DTD4310
DTD4312
DTD4314
DTD4808
DTD4810
DTD4812
DTD4814
DTD5108
DTD5110
DTD5112
DTD5114
8mm
10mm
12mm
14mm
Straight twist drill
L
L
L
L
DiameterLength Ø2.2 Ø2.8 Ø3.5 Ø4.2
DTD2208
DTD2210
DTD2212
DTD2214
DTD2808
DTD2810
DTD2812
DTD2814
DSTD3508
DSTD3510
DSTD3512
DSTD3514
DSTD4208
DSTD4210
DSTD4212
DSTD4214
8mm
10mm
12mm
14mm
Tap Drill
Diameter
Code
Ø3.5 Ø3.7 Ø4.1 Ø4.3 Ø4.8 Ø5.1
DTM35 DTM37 DTR41 DTR43 DTW48 DTW51
i-Clean No-mount driver
Code DMMDI
s-Clean No-mount driver
Code DMMDS
i-Clean Ratchet driver
Type
Code
Short
DRMDIS
Long
DRMDIL
Straight tap drill
Diameter
Code
Ø4.1
DSTR41
Ø4.8
DSTW48
s-Clean Ratchet driver
Type
Code
Short
DRMDSS
Long
DRMDSL
100 | 101 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
0.5㎜
Ø4.1 Ø4.8
8㎜
10㎜12㎜14㎜
Mount driver for ratchet
Type
Code
e-Clean 3.5 / Tap drill
DRHDS24 DRHDL24
e-Clean 4.1 / 5.1
DRHDS30 DRHDL30
Short Long Short Long
Octa driver
Type
Code
Short
DOADS
Long
DOADL
Code DSAD
Solid driver
Code DESAD
Excellent Driver
Hex driver
Type
Code
0.9 Hex
DRD09
1.2 Hex
DRD12S DRD12L
1.25 Hex
DRD125S DRD125L
Short Long Short Long
Mount driver for machine
Type
Code
e-Clean 3.5 / Tap drill
DMHD24
e-Clean 4.1 / 5.1
DMHD30
Torque ratchet
Code DTR
O-ring driver
Type
Code
Short
DORADS
Long
DORADL
Ratchet wrench
Code DRW
Estheticone driver
Type
Code
4.1
DEED
5.1
DEWD
102 | 103 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
8㎜
6㎜7㎜
12㎜10㎜
12㎜10㎜
SAVE Surgical Tools
Tap drill
Diameter
Code
5.5
DTW55
6.0
DTW60
8㎜
6㎜7㎜
SAVE twist drill
Length
8mm
12mm
Diameter
DSD5508
DSD5512
5.5 6.0
DSD6008
DSD6012
2㎜
10㎜
13㎜16㎜
2㎜
2㎜
2㎜
L
Mini machine driver
I-Fix Surgical Tools
Type
Short
Length Code
26mm DMMS
Long 31mm DMML
Mini ratchet driver
Type
Short
Length Code
26mm DMRS
Long 31mm DMRL
104 | 105 Ⅲ Recommendation Ⅳ Construction Ⅴ Surgical KitⅡ TechniqueⅠGuide
Straight twist drill
Ø2.3
DMD23
Ø1.8
DMD18
Ø1.3
DMD13
Diameter
Code
L
2㎜2㎜
Code DMDP
Depth gauge
10㎜
13㎜16㎜
ø1.8
ø1.3
10㎜
Products would not be made if they are notof the best quality.