(MIN) STANDARD METER TUBE LENGTHS PER AGA/API 14.3 - 2000 No Conditioner or Vane Upstream lengths (UL) are based on the largest expected published I.D. for a given size and rounded up to nearest inch at 44D. Downstream lengths exceed the minimum recommended minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4" threadolet or coupling, spaced 6” apart. 2 SECTION METER TUBES SIZE UL (44D) DL (4.5D +24”) 2 7'-10" 3'-0" 3 11'-4" 3'-6" 4 14'-13" 4'-0" 6 22'-4" 4'-6" 8 29’-5” 5'-0" 10 36’-12” 6'-0" 12 43’-13” 6'-6" 14 48’-3” 7'-0" 16 55’-0” 8'-0" 18 62’-0” 8'-6" 20 69’-0” 9'-6" 24 83’-0” 10'-8" 19 – Tube Bundle LSV Upstream lengths (UL) are based on the largest expected published I.D. for a given size and rounded up to nearest inch at 29D. Downstream lengths exceed the minimum recommended minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4" threadolet or coupling, spaced 6” apart. 2 SECTION METER TUBES W/ VANES SIZE UPSTREAM DOWNSTREAM VANE LOCATION VL 2* 5'-0" 3'-0" 3 7'-5" 4'-0" 3'-8" 4 9'-9" 4'-0" 4'-10" 6 14'-8" 5'-0" 7'-1" 8 19'-8" 5'-0" 9'-6" 10 24'-10" 6'-0" 12'-0" 12** 29'-8" 7'-0" 13'-5-1/2" / 15'- 2-1/2"
Transcript
Page 1: AGA 14-3 Meter Tube Pipe Lengths

(MIN) STANDARD METER TUBE LENGTHS PER AGA/API 14.3 - 2000

No Conditioner or VaneUpstream lengths (UL) are based on the largest expected published I.D. for a given size and rounded up to nearest inch at 44D. Downstream lengths exceed the minimum recommended minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4" threadolet or coupling, spaced 6” apart.

2 SECTION METER TUBESSIZE UL (44D) DL (4.5D +24”)

2 7'-10" 3'-0"3 11'-4" 3'-6"4 14'-13" 4'-0"6 22'-4" 4'-6"8 29’-5” 5'-0"10 36’-12” 6'-0"12 43’-13” 6'-6"14 48’-3” 7'-0"16 55’-0” 8'-0"18 62’-0” 8'-6"20 69’-0” 9'-6"24 83’-0” 10'-8"

19 – Tube Bundle LSVUpstream lengths (UL) are based on the largest expected published I.D. for a given size and rounded up to nearest inch at 29D. Downstream lengths exceed the minimum recommended minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4" threadolet or coupling, spaced 6” apart.

2 SECTION METER TUBES W/ VANESSIZE UPSTREAM DOWNSTREAM VANE LOCATION VL

2* 5'-0" 3'-0"3 7'-5" 4'-0" 3'-8"4 9'-9" 4'-0" 4'-10"6 14'-8" 5'-0" 7'-1"8 19'-8" 5'-0" 9'-6"10 24'-10" 6'-0" 12'-0"

12** 29'-8" 7'-0" 13'-5-1/2" / 15'-2-1/2"14** 32'-4" 8'-7" 14'-7-1/2" / 16'-8-1/2"16** 37'-2" 9'-4" 18'-1-1/2" /20'-6-1/2"18** 42'-0" 10'-1" 20'-5-1/2" / 23'-2-1/2"20** 46'-7" 10'-11" 22'-8-1/2" / 25'-9-1/2"24** 56'-3" 12'-7" 27'-4-1/2" / 31'-1-1/2"

*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes**12" and larger have 2 setscrews. Numbers shown are to 1st, then to 2nd setscrew

2 section tubes 3 Section tubes

Page 2: AGA 14-3 Meter Tube Pipe Lengths

3 SECTION METER TUBES WITH FLANGED TYPE VANESSIZE UPSTEAM

LENGTHTOTAL

INLET SPOOL including vane flange(s), 3 gaskets and 1/2" spacer

plate Catalog "S"

UPSTREAM SPOOLFlange face to orifice

plate centerlineCatalog "U"

DOWNSTREAMLENGTH

2* 5'-0" 2'-3" 2'-9" 3'-0"3 7'-5" 3'-5" 4'-0" 4'-0"4 9'-9" 4'-6" 5'-3" 4'-0"6 14'-8" 7'-1" 7'-7" 5'-0"8 19'-8" 9'-6" 10'-2" 5'-0"10 24'-10" 12'-0" 12'-10" 6'-0"12 29'-8" 14'-4" 15'-4" 7'-0"14 32'-4" 15'-6" 16'-10" 8'-7"16 37'-2" 17'-10" 19'-4" 9'-4"18 42'-0" 20'-2" 21'-10" 10'-1"20 46'-7" 22'-4" 24'-3" 10'-11"24 56'-3" 27'-0" 29'-3" 12'-7"

*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes

3 SECTION METER TUBES WITH PROFILERSIZE UPSTEAM

LENGTHTOTAL

INLET SPOOL including 1/2" spacer

plate (9.5D min)

UPSTREAM SPOOLFlange face to orifice

plate centerline

DOWNSTREAMLENGTH

2 3'-4" 1'-11" 1'-5" 3'-0"3 4'-7" 2'-7" 2'-0" 4'-0"4 6'-1" 3'-4" 2'-9" 4'-0"6 8'-10" 4'-13" 3'-13" 5'-0"8 11'-6" 6'-6" 5'-0" 5'-0"10 14'-5" 8'-0" 6'-5" 6'-0"12 17'-4" 9'-8" 7'-8" 7'-0"14 18'-11" 10'-7" 8'-4" 8'-7"16 19'-7" 12'-0" 9'-7" 9'-4"18 24'-3" 13'-6" 10'-9" 10'-1"20 26'-13" 15'-0" 11'-13" 10'-11"24 32'-3" 18'-0" 14'-3" 12'-7"

Note: Minimum Length Upstream for TOL/HC is 36” from Profiler or Vane inlet.

Page 3: AGA 14-3 Meter Tube Pipe Lengths

(MIN) STANDARD METER TUBE LENGTHS PER AGA/API 14.3 - 2002

No Conditioner or VaneUpstream lengths (UL) are based on the largest expected published I.D. for a given size and rounded up to nearest inch at 44D. Downstream lengths exceed the minimum recommended minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4" threadolet or coupling, spaced 6” apart.

2 SECTION METER TUBESSIZE UL (44D) DL (4.5D +24”)

2 7'-10" 3'-0"3 11'-4" 3'-6"4 14'-13" 4'-0"6 22'-4" 4'-6"8 29’-5” 5'-0"10 36’-12” 6'-0"12 43’-13” 6'-6"14 48’-3” 7'-0"16 55’-0” 8'-0"18 62’-0” 8'-6"20 69’-0” 9'-6"24 83’-0” 10'-8"

19 – Tube Bundle LSVUpstream lengths (UL) are based on the largest expected published I.D. for a given size and rounded up to nearest inch at 29D. Downstream lengths exceed the minimum recommended minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4" threadolet or coupling, spaced 6” apart.

2 SECTION METER TUBES W/ VANESSIZE UPSTREAM DOWNSTREAM VANE LOCATION VL

2* 5'-0" 3'-0"3 7'-5" 4'-0" 3'-8"4 9'-9" 4'-0" 4'-10"6 14'-8" 5'-0" 7'-1"8 19'-8" 5'-0" 9'-6"10 24'-10" 6'-0" 12'-0"

12** 29'-8" 7'-0" 13'-5-1/2" / 15'-2-1/2"14** 32'-4" 8'-7" 14'-7-1/2" / 16'-8-1/2"16** 37'-2" 9'-4" 18'-1-1/2" /20'-6-1/2"18** 42'-0" 10'-1" 20'-5-1/2" / 23'-2-1/2"20** 46'-7" 10'-11" 22'-8-1/2" / 25'-9-1/2"24** 56'-3" 12'-7" 27'-4-1/2" / 31'-1-1/2"

*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes**12" and larger have 2 setscrews. Numbers shown are to 1st, then to 2nd setscrew

Page 4: AGA 14-3 Meter Tube Pipe Lengths

3 SECTION METER TUBES WITH FLANGED TYPE VANESSIZE UPSTEAM

LENGTHTOTAL

INLET SPOOL including vane flange(s), 3 gaskets and 1/2" spacer

plate Catalog "S"

UPSTREAM SPOOLFlange face to orifice

plate centerlineCatalog "U"

DOWNSTREAMLENGTH

2* 5'-0" 2'-3" 2'-9" 3'-0"3 7'-5" 3'-5" 4'-0" 4'-0"4 9'-9" 4'-6" 5'-3" 4'-0"6 14'-8" 7'-1" 7'-7" 5'-0"8 19'-8" 9'-6" 10'-2" 5'-0"10 24'-10" 12'-0" 12'-10" 6'-0"12 29'-8" 14'-4" 15'-4" 7'-0"14 32'-4" 15'-6" 16'-10" 8'-7"16 37'-2" 17'-10" 19'-4" 9'-4"18 42'-0" 20'-2" 21'-10" 10'-1"20 46'-7" 22'-4" 24'-3" 10'-11"24 56'-3" 27'-0" 29'-3" 12'-7"

*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes

3 SECTION METER TUBES WITH PROFILERSIZE UPSTEAM

LENGTHTOTAL

INLET SPOOL including 1/2" spacer

plate (9.5D min)

UPSTREAM SPOOLFlange face to orifice

plate centerline

DOWNSTREAMLENGTH

2 3'-4" 1'-11" 1'-5" 3'-0"3 4'-7" 2'-7" 2'-0" 4'-0"4 6'-1" 3'-4" 2'-9" 4'-0"6 8'-10" 4'-13" 3'-13" 5'-0"8 11'-6" 6'-6" 5'-0" 5'-0"10 14'-5" 8'-0" 6'-5" 6'-0"12 17'-4" 9'-8" 7'-8" 7'-0"14 18'-11" 10'-7" 8'-4" 8'-7"16 19'-7" 12'-0" 9'-7" 9'-4"18 24'-3" 13'-6" 10'-9" 10'-1"20 26'-13" 15'-0" 11'-13" 10'-11"24 32'-3" 18'-0" 14'-3" 12'-7"

Note: Minimum Length Upstream for TOL/HC is 36” from Profiler or Vane inlet.