    HP 37717CCommunicationsPer formance Analyzer

    Quick Sta rt

    Guide

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    2/38

    Hewlett-Packard LimitedTelecomm un icat ions N etwork s Test Division

    South Queensferry

    West Loth ian, Scotlan d EH 30 9TG

    Copyright H ewlett-

    Packard Lt d.1998

    All rights reserved.

    Reproduction,

    ada ption, or

    tra nslation without

    prior written

    permission is

    prohibited, except as

    allowed under th e

    copyright laws.

    HP Par t No.37717-90401

    First edition , 03/98

    Pr inted in U.K.

    Documentat ionWarranty

    The in form at ion

    cont ained in th is

    docum ent is subject t o

    cha nge without notice.

    Hewlett-Packard m akes

    no warranty of any

    kin d with regard to this

    m aterial, including,

    but n ot limited to, the

    im plied w arranties orm erchan tability and

    fitn ess for a particular

    purpose.

    Hewlett-Packard shall

    not be liable for er rors

    contained herein or for

    incidental or

    consequentialdamages in connection

    with the furnishing,

    performa nce, or use of

    this material.

    WARNING

    For det ails of safety,

    see Safety information

    at t he front of th e

    Calibration ma nua l.

    Warning Symbols

    Used on t he Pr oduct

    The product is mark ed

    with t his symbol when

    the u ser should refer t o

    the instruction

    manu al in order to

    protect the appar atu s

    against dam age.

    The pr oduct is

    mar ked with this

    symbol to indicat e th at

    ha zardous voltages are

    present

    The product is mar ked

    with t his symbol to

    indicate t hat a laser is

    fitt ed. The user sh ould

    refer to the laser safety

    inform at ion in th eCalibration Manual.

    !

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    3/38

    Quick Sta rt Guide

    HP 37717C Communica t ionsPer formance Analyzer

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    4/38

    2

    The Quick Sta rt Gu ide demonstra tes th e basic operat ion of th e inst ru ment .

    This guide tells you h ow to select t he displays tha t you want an d how to use th em t o modify

    the instrum ent functions.

    This guide also tells you a bout th e front pan el key fun ctions, th e indicat ors a nd t he

    connectors.

    Abou t This Boo k

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    5/38

    Contents

    iii

    Int roduction to the 37717C Front Pan el 7

    Selectin g Displays 8

    Selecting Multiple or Single Windows 9

    Moving Around Multiple Windows 10

    Selecting the Graph or Other Display in Multiple Windows 11Changing the Displayed Folder 13

    Changing the Instrum ent Settings 14

    Modifying Displays with Pop-up Menus 16

    Making Selections using Pictorial and Graphic Displays. 20

    Using with a Monitor 24

    Using the Oth er Front Pa nel Keys 25

    Monitoring Stat us 27

    Displaying S ta tus His tory 27Genera l Ala rm Ind ica tor s 28

    PDH / DSn Ala rm Indica tor s 28

    ATM Alarm Ind ica tor s 28

    J i tt er Ala r m In dica t or s 28

    S DH Ala r m In dica t or s 29

    SONET Alarm Indicators (Option 120) 29

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    6/38

    iv

    Contents

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    7/38

    Getting Started

    This cha pter shows you h ow to select a nd

    cha nge displays

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    8/38

    6

    Getting Started

    Getting St ar ted sh ows you h ow to select displays and use t hem to cha nge

    th e instr um ent settings. Gett ing star ted includes th e following:

    How to select sin gle or m ult iple windows

    How to obtain th e required display using t he display select k eys,; ; ; ;

    How to modify the display informat ion , using andan d t he display softkeys or pop-up m enus

    How to use th e oth er front pan el keys

    How to inter pret t he front pan el sta tu s indicat ors

    How to conn ect to externa l equipment

    TRANSMIT RECEIVE RESULTS GRAPH OTHER

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    9/38

    7

    Getting Started

    Introduction to the 37717C Front Panel

    Introduc tion to the 37717C Front Pane l

    The opera tor inter face is provided by the display and th e front pa nel

    keys.

    The displa y ma y be mult iple windows or a single window.

    When t he display is mu ltiple windows, th e "active" window is indicat ed

    with a color which is different from t he color of th e th ree "inactive"

    windows.

    LOS

    PATTERN LOSS

    ERRORS

    AIS

    FRAME LOSS

    M/F LOSS

    REMOTE ALARM

    REMOTE M/F ALARM

    VP ALARM

    VC ALARM

    LOSS OF CELL SYNC

    SELECTED CELL NOT RX

    JITTER UNLOCK

    JITTER HITS

    FRAME LOSS

    LOSS OF POINTER

    MS-AIS

    AU-AIS

    CLOCK LOSS

    MS-RDI

    HP-RDI

    TU-AIS

    LP-RDI

    POINTER ADJUST

    HISTORY

    SHOW RESETHISTORY HISTORY

    RUN/

    STOP

    PAPER PRINT

    FEED NOW

    TRANSMIT

    RECEIVE

    RESULTS

    GRAPH

    OTHER

    SET

    CANCEL

    Received signaland alarm conditionSelect display

    Start/ stop test

    Manual printer/logging controls

    Move cursorControl

    pop up menu

    SDH/SONET

    PDH/DSn

    ATM

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    10/38

    8

    Getting Started

    Selecting Displays

    Select ing Displays

    A mu ltiple window display is available. The displayed pa ges are:

    Transmitt er Out put, Receiver Input, Results and either Graph or Ot her

    (Function).

    Allows control of the settings associated with the generated signal.

    Allows cont rol of th e sett ings ass ociat ed with th e received signal.

    Allows cont rol of the test timing a nd gra ph st ora ge and displays theselected measurement results.

    Allows ma na gement of the st ored gra phical results.

    Allows cont rol of Stored Set tin gs, Sett ings Contr ol, Floppy Disk,

    Logging, Remote Contr ol, Time & Dat e, Miscellaneous (Keyboar d Lock,

    Beep on Received Er ror, Sus pend Test on Signal Loss), Option a nd

    Option Enable, Calibration, Autosetup and Color Control.

    A list of Options fit ted is also displayed.

    TRANSMIT

    RECEIVE

    RESULTS

    GRAPH

    OTHER

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    11/38

    9

    Getting Started

    Selecting Displays

    Select ing Mult iple or Single Window s

    To select single window, use th e display k eys ; ;; and , to select the display required and

    then press .

    Most examples in th is man ua l use SINGLE window. To retu rn to

    multiple windows, press .

    Exa mple: To obt ain a single window t ra nsm it display, Use to

    make the tra nsmit window active.

    TRANSMIT RECEIVE

    RESULTS GRAPH OTHER

    SINGLE WINDOW

    MULTIPLE WINDOW

    TRANSMIT

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    12/38

    10

    Getting Started

    Selecting Displays

    Use to obta in a

    single tr an smit window display

    To cha nge th e page displayed in

    th e single window, press th e page

    key for t he pa ge requir ed (e.g.

    RECE IVE, RESU LTS, GRAPH or

    OTHER) .

    When retur ning to multiple

    windows, the curr ent single

    window display will become th e

    active display with in th e mu ltiple

    windows.

    Movin g Aroun d Multiple Wind ow s

    To move the cursor t o an other of th e displayed windows, press th e

    display selection k ey for th at window.

    Example : The cursor is in th e TRANSMITTER OUTPUT window at th e

    top left of th e displa y.

    .

    SINGLE WINDOW

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    13/38

    11

    Getting Started

    Selecting Displays

    If you want to ma ke chan ges to the receive display, you need t o make th e

    receive display "active". To move th e cursor t o the RE CEIVER IN PU Twindow a t the top r ight of the display, press .

    Select ing the Graph or Other Display in Mult ipleWindows

    Press or for the display tha t you want .

    Example: To change the display from to . Press

    .

    RECEIVE

    OTHER GRAPH

    OTHER GRAPH

    GRAPH

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    14/38

    12

    Getting Started

    Selecting Displays

    Display with FUNCTION

    Press to change to the graph display

    OTHER

    GRAPH

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    15/38

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    16/38

    14

    Getting Started

    Changing the Instrument Settings

    Changing the Instrument Se tt ings

    Sett ings which may be cha nged ar e displayed in a different color to th ose

    which ar e fixed. In t his ma nu al, var iable settin gs are shown on t he

    displays in [ ].

    In each of th e display ar eas th e

    field curr ent ly able to be cha nged

    is mar ked by a highlighted cursor.

    The high light ed cur sor is moved

    ar oun d the display using

    and .

    The m enu of selections a vailable,

    for th e highlight ed field, appear s

    at the bot tom of the display: ; ; . The choice from the

    menu is made u sing the display softkeys situa ted imm ediately below th e

    display.

    When a field has more tha n five

    choices, as in SPE ED sh own here, a

    softkey labelled is provided.

    RS232 HP IB DISK

    MORE

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    17/38

    15

    Getting Started

    Changing the Instrument Settings

    When is chosen the

    rema inder of th e menu is revealed.

    MORE

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    18/38

    16

    Getting Started

    Changing the Instrument Settings

    Modifying Displays w ith Pop-up Menu s

    Alth ough th e met hod of modifying the displa ys with softk eys is always

    available, it is ea sier in ma ny cases to use the Pop-up m enus.

    The pop-up m enus ar e par ticularly useful for:

    Text entr y

    Date/time entr y

    Int eger, Hexadecima l and Binar y entry Trace data ent ry

    Menu selection when th ere a re a large nu mber of choices

    SDH/SONET payload m apping

    ATM physical a nd ada pta tion layer selections

    Jitter mask selections

    If an a tt empt is ma de to set out of ra nge values, the instr um ent will

    adopt t he n earest possible legal value.

    Text, Trace Da ta, Date a nd Time, Integ er and He xade cimalSelect ion.

    Move th e cur sor to th e field to be cha nged.

    Press for the pop-up menu.

    The curr ent selection is shown in a window at th e top of the pop-up

    menu.

    To move thr ough th e cur rent sett ing in th e

    window use and to select

    or .

    Use t o m ove t o t he r equ ir ed field.

    SET

    >

    SET

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    19/38

    17

    Getting Started

    Changing the Instrument Settings

    Select t he r equired chara cter or fun ction

    on the pop-up menu with and.

    Pres s to s et the se lect ion in the window a t the top of the pop-up

    menu.

    When t he required cont ent is displayed in t he window at th e top of th e

    pop-up menu, select and press to change the inst rument

    sett ing to th e new value.

    To exit th e m en u display wit hou t m akin g t he ch an ge, pr ess .

    Example:

    The pop-up menu provides a more convenient met hod of entering st ored

    set t ing t i t les. Move the cursor in to one of the t it le fields and press .

    SET

    END SET

    CANCEL

    SET

    SET

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    20/38

    18

    Getting Started

    Changing the Instrument Settings

    Binary Entry

    For fie lds which r equ ir e bina ry da ta ent ry, u se to d isplay the pop-

    up menu.

    The curren t sett ing is shown in a window at t he top of th e pop-up m enu.

    To move th rough the s elected en t ry with the pop-up menu use and

    see page 16.

    Bin a ry select ion is ach ieved wit h = 0 a n d = 1. Th is oper a tion

    enter s th e selected char acter, 0 or 1, an d moves to th e next char acter.

    This met hod allows ra pid sett ing of bina ry words. For exam ple:

    To set the word 11110011 Use .

    Selection of th e last chara cter chan ges the instr um ent set ting to the new

    value.

    To exit th e m en u displa y wit hou t m akin g t he ch an ge, pr ess .

    Example:

    The binar y pop-up m enu m aybe used to set u p a u ser defined word. In

    th is example th e user defined word is a n ATM payload ba ckground byte.

    SET

    >

    CANCEL

    SET

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    21/38

    19

    Getting Started

    Changing the Instrument Settings

    Menu Select ion

    There is a menu selection available as an alter na tive to any group of soft

    keys. Display the menu with . Use and to make the

    selection.

    To change to the new va lue, p res s . To exit the display withou t

    making the change, press .

    Example:

    SET

    SET

    CANCEL

    SET

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    22/38

    20

    Getting Started

    Changing the Instrument Settings

    Making Se lect ions us ing P ictorial and Graphic

    Displays.

    In some cases selection is simplified with a pictorial or gra phic "ma p"

    display. This facili ty is available where the display has a symbol.

    These displays are obtained in th e same way as th e pop-up men us using

    . Some of these displays include m enus which allow th e sett ings to

    be changed.

    NOTE Details of th e pictorial display depend on th e optiona l modules fitted tothe instrument.

    SDH Payload Mapping

    With the cu r sor in the MAPPING fie ld , p res s to d isplay the payload

    map.

    To cha nge bet ween AU- layer, TU-layer an d Pa yload layer selections, useand .

    To select the mapping you want , use and .

    To change to the new value, press . To exit the map d isplay without

    ma king the cha nge, press .

    .Example:

    +

    SET

    SET

    SET

    CANCEL

    SET

    AU-layer TU-layerPayloadlayer

    G tti St t d

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    23/38

    21

    Getting Started

    Changing the Instrument Settings

    ATM Ph ysical Layer Se lections

    With t he cur sor in t he ATM, PHYSICAL LAYER, SIGN AL field, press

    t o displa y t he ph ysica l in ter fa ce. U se a nd t o select t he

    inter face you wa nt .

    To ch an ge t o t he n ew va lu e, pr ess .

    To exit th e m ap displa y wit hou t m akin g t he ch an ge, pr ess .

    Example:

    SET

    SET

    CANCEL

    SET

    Getting Started

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    24/38

    22

    Getting Started

    Changing the Instrument Settings

    Jitte r Mask Selec tion

    Graph ical displays of jitter ma sk selections ar e available. The curr ent

    settings a re shown by a ma rker on t he gra phical display.

    Jitte r Mask se t to Off

    To obta in a gra phical display, move th e cursor t o RANGE,

    MODU LATI ON F RE QU E NCY, or AMP LI TU DE a n d p res s .

    To change a value, use and to select the parameter you

    want to cha nge, RANGE, MOD FRE Q OR AMPLITUDE.

    Press for a pop-up menu.

    Mak e your selection from t he pop-up m enu as described in Modifying

    Displays with Pop-up Menus page 16 a nd press a gain to select t he

    new value.

    The ma rker on t he gra phical display will move to the new position an d

    set th e new value.

    To exit t he gr aph ica l displa y wit h t he n ew va lu e set , pr ess .

    SET

    SET

    SET

    CANCEL

    SET

    Getting Started

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    25/38

    23

    Getting Started

    Changing the Instrument Settings

    Jit ter Mask set to Sw ept

    To obta in a pictoria l display, move the cur sor to J ITTER MASK [SWEP T]

    and p res s . The marker moves con t inuous ly th rough the sweep

    range.

    To exit the pictor ia l display use .

    To change the fr equency, p res s for a pop-up menu .

    Use and to make your select ion from the pop-up menu

    a nd pr ess a ga in to select th e n ew va lu e

    To exit t he gra phical display with th e new value set, press

    SET

    CANCEL

    SET

    SET

    SET

    CANCEL

    Getting Started

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    26/38

    24

    Getting Started

    Using with a Monitor

    Jitte r Mask set to Spo t

    To obta in a gra phical display, move the cur sor to SPOT FRE QUE NCY

    and press .

    .

    To change the fr equency pres s for a pop-up menu of the va lues

    available.

    Use and to make your select ion from the pop-up menu

    a nd pr ess a ga in to select t he n ew va lu e.

    The ma rker on t he gra phical display will move to the new position an dupdate t he value.

    To exit t he gra phical display with th e new value set, press

    Using w ith a Monitor

    For ea se of viewing at a dista nce, th e instr um ent display ma y be

    present ed on a monitor. The monitor should be conn ected t o the H P

    37717C front panel VGA connector.

    SET

    SET

    SET

    SET

    CANCEL

    Getting Started

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    27/38

    25

    Gett g Sta ted

    Using the Other Front Panel Keys

    Using th e Other Front Panel Keys

    The test set a tt empts t o ma tch the sett ings to th e received signal.

    Termin at es the curr ent t est period if one is in progress. Start s a n ew test

    period. The indicat or a bove the key is lit when a test period is inprogress.

    Adds a single bit err or t o the outpu t da ta patt ern each time th e key is

    pressed.

    Retur ns t he inst ru ment from rem ote opera tion to Local (keyboar d)

    operat ion. The indicat or a bove the key is lit when t he instr um ent is

    un der Remote Control.

    Displays th e pop-up m enu for t he curr ently highlight ed field. This key

    also confirms the selection made.

    Clears th e pop-up m enu without chan ging th e selection.

    The selected m easur ement results ar e logged, immediately, to the

    selected printer.

    The paper in th e internal print er is advanced.

    LOS

    PATTERN LOSS

    ERRORS

    AIS

    LOF

    M/F LOSS

    REMOTE ALARM

    REMOTE M/F ALARM

    VP ALARM

    VC ALARM

    LOSS OF CELL SYNC

    SELECTED CELL NOT RX

    JITTER UNLOCK

    JITTER HITS

    PDH/DSn

    ATM

    FRAME LOSS

    LOSS OF POINTER

    MS-AIS

    AU-AIS

    CLOCK LOSS

    MS-RDI

    HP-RDI

    TU-AIS

    LP-RDI

    POINTER ADJUST

    HISTORY

    SDH/SONET

    AUTO SETUP

    RUN/STOP

    SINGLE

    LOCAL

    SET

    CANCEL

    PRINT NOW

    PAPER FEED

    Getting Started

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    28/38

    26

    g

    Using the Other Front Panel Keys

    CAUTION Do not press while a t tempt ing to load a new roll of paper in

    th e print er. It could result in a pa per jam a nd disable the pr inter. Wait

    un til the paper is fed thr ough th e printer m echa nism before pressing

    .

    PAPER FEED

    PAPER FEED

    Getting Started

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    29/38

    27

    Monitoring Status

    Monitoring Status

    Displaying Status History

    The Sta tu s indicat ors on t he front pan el convey inform at ion r egarding

    the current stat us of the instru ment. If an a larm h as occurr ed during the

    current Test Per iod, the indica tor above is lit . To view

    which a larms have occurred, press and hold . When

    is released th e stat us indicat ors ret ur n to displaying the

    current s tatus .

    When pressed an d held, th e Stat us indicat ors display any alarm s which

    ha ve been set du ring th e cur rent Test Period. This cont inues un til

    is released at which t ime the current stat us is

    displayed. The indicat or a bove the key is lit t o signify th at an alar m h asoccur red du ring th e cur rent Test Period.

    Resets th e history store such tha t t he historical an d present sta tus are

    th e sam e. This can a lso be achieved by sta rt ing a n ew Test Period.

    LOSS

    ERRORS

    PATTERN LOSS

    AIS

    FRAME LOSS

    M/FRAME LOSS

    REMOTE ALARM

    REMOTE M/FRAME ALARM

    VP ALARM

    VC ALARM

    LOSS OF CELLSYNC

    SELECTED CELL NOT RX

    JITTER UNLOCK

    JITTER HITS

    FRAME LOSS

    LOSS OF POINTER

    MS-AIS

    AU-AIS

    CLOCK LOSS

    POINTER ADJUST

    LP-RDI

    SDH/SONET

    PDH/DSn

    ATM

    MS-RDI

    HP-RDI

    TU-AIS

    SHOW HISTORY

    SHOW HISTORY

    SHOW HISTORY

    SHOW HISTORY

    SHOW HISTORY

    RESET HISTORY

    Getting Started

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    30/38

    28

    Monitoring Status

    Gene ral Alarm Indicato rs

    Loss No data tra nsitions at the input port.

    Pattern Loss The received data pat tern is not in synchronizat ion

    with t he intern ally generated reference dat a.

    Errors A measur ed err or h as occur red. The indicator will

    rema in lit for 100 m s.

    PD H / DSn Alarm Indica torsThese ar e active when a P DH / DSn signal is received

    AIS The All Ones AIS signal is det ectable in t he pr esence of

    a 1 in 10-3 error ra te.

    Frame Loss Fra me a lignm ent lost or out of alignment condition.

    M/Frame Loss Multifra me alignment lost.

    Remote Alarm Remote a larm , x-bit or yellow alar m bit is set.

    Remote M/

    Frame Alarm Remote Multifra me Alarm bit is set.

    ATM Alarm Indi cato rs

    These a re a ctive when an ATM signa l is received.

    VP Alarm Virtu al Pat h AIS or FE RF ha s been detected.

    VC Ala rm Virtu al Chan nel AIS or FE RF ha s been detected.

    Loss of Cell

    Sync Cell Sync Loss ha s been det ected.

    Selected CellNot RX The selected cell ha s n ot been received.Selected cell not

    received.

    Jitte r Alarm Indicators

    Jit ter Unlock The jitter r eceiver h as lost pha se lock. J itter

    mea surem ent is suspended u nt il lock is regained.

    Jitte r Hits A jitter hit h as been detected.

    Getting Started

    M i i S

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    31/38

    29

    Monitoring Status

    SDH Alarm Indic ators

    These ar e active when an SDH signal is received.

    FRAME LOSS Loss Of Fram e ha s been detected.

    LOSS OF

    POINTER Loss of point er h as been d etected.

    MS-AIS Multiplexer Section AIS has been detected.

    AU-AIS Pat h AIS has been detected.

    CLOCK LOSS The tr an smitt er clock is not synchronized to the

    selected referen ce.

    MS-RDI Multiplexer Section RDI (FERF ) ha s been detected.

    HP-RDI Pat h RDI (FE RF) ha s been detected.

    TU-AIS TU Pat h AIS has been detected. .

    LP-RDI TU Path RDI (FE RF) ha s been detected. .

    POINTER

    ADJUST A pointer cha nge in t he foreground signal h as been

    detected.

    SONET Alarm Ind icators (Option 120)

    These ar e active when a SONE T signa l is received.

    LOF/SEF Loss of Fram e or Severely Errored Fr am e ha s been

    detected. Statu s m essage on bottom of display sta tes

    which ha s occur red.

    LOP-P/LOP-V Loss of Point er h as been det ected.

    AIS-L Line AIS ha s been detected.

    AIS-P STS Path AIS has been detected.

    CLOCK LOSS The tr an smitt er clock is not synchronized to the

    selected referen ce.

    RDI-L Line Remote Defect In dication (RDI) ha s been

    detected.

    RDI-P STS Path RDI has been detected.

    AIS-V Virtu al Tributa ry path AIS has been detected.

    Getting Started

    Monitoring Stat s

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    32/38

    30

    Monitoring Status

    RDI-V VT pat h RDI ha s been detected.

    POINTER

    ADJUST A pointer cha nge in t he foreground signal h as been

    detected.

    Index

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    33/38

    31

    AAIS alarm indicator, 28Alarm Indicator

    AIS, 28Errors, 28Frame loss, 28HP-RDI, 29Jitter unlock, 28LOF/OOF, 29Loss of cell sync, 28LP-RDI, 29M/Frame loss, 28MS-RDI, 29Pattern Loss, 28Pointer adjust, 29Remote alarm, 28

    Remote M/frame alarm, 28Selected cell not received, 28Signal Loss, 28TU-AIS, 29TU-LOP, 29VC Alarm, 28VP alarm, 28

    Alarm IndicatorsATM, 28General, 28Jitter hits, 28

    PDH / DSn, 28SDH, 29

    ATM Alarm Indicators, 28ATM Alarms

    Loss of Cell Sync, 28Selected Cell Not Received, 28VC Alarm, 28VP Alarm, 28

    ATM layer selections with pop-up menus,21

    AU-AIS Alarm IndicatorAlarm IndicatorAU-AIS, 29Auto Setup key, 25

    BBinary entry with pop-up menu, 18

    CCancel key, 25Changing settings on displays, 14Changing settings with soft keys, 14

    Clock Loss Alarm IndicatorAlarm Indica-tor

    Clock loss, 29Cursor

    Introduction to, 14Moving, 14

    DDate and time entry with pop-up menu, 16Display on a monitor, 24Displaying list of, 8Displays

    Changing settings on, 14DSn Alarm Indicators, 28

    E

    Errors Alarm Indicator, 28

    FFolder

    Selecting, 13Frame Loss Alarm Indicator, 28

    GGraph key, 8Graphic displays as a selection aid, 20

    HHexadecimal entry with pop-up menu, 16History Keys, 27HP-RDI Alarm Indicator, 29

    I

    IndicatorsFront Panel, 28

    Integer entry with pop-up menu, 16

    JJitter Alarm Indicators, 28Jitter hits alarm indicator, 28Jitter Unlock alarm indicator, 28

    KKeys

    Auto Setup, 25Cancel, 25Graph, 8Local, 25

    Other, 8Paper Feed, 25Print Now, 25Receive, 8Reset History, 27Results, 8Run / Stop, 25Set, 25Show History, 27Transmit, 8

    LLocal key, 25LOF alarm indicator, 29Loss of Cell Sync Alarm Indicator, 28Loss Of Pointer Alarm IndicatorAlarm In-

    dicatorAU-LOP, 29

    LP-RDI Alarm Indicator, 29

    M

    M/Fame Loss Alarm Indicator, 28Menus, pop-up, obtaining, 16Monitor,connecting, 24MS-AIS Alarm IndicatorAlarm Indicator

    MS-AIS, 29MS-RDI Alarm Indicator, 29Multiple windows

    Moving between, 10Selecting the undisplayed window, 11

    Multiple/single window selection, 9

    O

    OOF alarm Indicator, 29Options fitted, 8Other key, 8

    PPaper Feed key, 25Pattern Loss Alarm Indicator, 28PDH / DSn Alarms

    AIS, 28Frame Loss, 28M/Frame Loss, 28Remote Alarm, 28Remote M/Frame Alarm, 28

    PDH Alarm Indicators, 28Pictorial displays as a selection aid, 20

    Index

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    34/38

    32

    Pointer Adjust Indicator, 29Pop-up menus

    As alternative to soft keys, 19Modifying displays with, 16

    Print Now key, 25

    RReceive key, 8Remote Alarm Indicator, 28Remote M/Frame Alarm Indicator, 28Reset History key, 27Results key, 8Run / Stop Key, 25

    S

    SDH Alarm Indicators, 29

    SDH AlarmsAU-AIS, 29Clock Loss, 29HP-RDI, 29Loss Of Pointer, 29LP-RDI, 29MS-AIS, 29MS-RDI, 29Pointer Adjust, 29TU-AIS, 29

    SDH payload mapping with pictorial dis-play, 20

    Selectable display values, 15Selected Cell Not Received Alarm Indica-

    tor, 28Set key, 25Settings

    changing with soft keys, 14Show History key, 27Signal Loss Alarm Indicator, 28Single/multiple window selection, 9

    Soft key alternative, pop-up menu, 19Soft keys

    using, 14Status Indicators, 27

    TText entry with pop-up menu, 16Trace data entry with pop-up menu, 16Transmit key, 8TU-AIS Alarm Indicator, 29

    VVC Alarm Indicator, 28VP Alarm Indicator, 28

    Hew lett-Pac kard Sales and Service Offices

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    35/38

    If you n eed technical a ssistan ce with a

    Hewlett-Packard t est and m easurement

    product or applicat ion please cont act t heHewlett-Packard office or distributor in

    your coun tr y.

    Asia Pacifi c:

    Hong K ong:

    Tel: (852) 2599 7889

    India:

    Tel: (91-11) 682-6000

    J a p a n :

    Hewlett-Packard Ja pan Lt d.

    Measurement Assistance Center

    9-1, Taka ku ra -Cho, Ha chioji-Shi,

    Tokyo 192-8510, Japan

    Tel: (81) 426-56-7832

    Fax: (81) 426-56-7840

    Korea:

    Tel: (82-2) 769 0800

    Malays ia:Tel: (60-3) 291 0213

    Phi l ipp ines :

    Tel: (63-2) 894 1451

    Peoples Rep ubli c of China :

    Tel: (86-10) 6505 0149

    Singapor e :

    Tel: (1800) 292 8100

    T a i w a n :

    Tel: (886-3) 492 9666

    T h a i l a n d :

    Tel: (66-2) 661 3900

    For countr ies in As ia Pa cific not l i s ted ,

    contact :

    Hewlett-Packard Asia Pacific Ltd

    17-21/F Shell Tower, Times Squa re,

    1 Mat heson Street

    Causeway Bay

    Hong Kong

    Tel: (852) 2599 7777

    Fax: (852) 2506 9285

    Aus tralia/New Zealan d:Hewlett-Packard Australia Ltd.

    31-41 J oseph St reet

    Blackbur n, Victoria 3130

    Australia

    Tel: 1 800 629 485

    Canada:Hewlett-Packard Canada Ltd.

    5150 Spectr um Way

    Mississauga, Ontario

    L4W 5G1

    Tel: (905) 206 4725

    Europe , Africa an d Middle East:

    Aus tr ia:

    Tel: (0)1 25000-0

    Belg ium an d Luxembourg:

    Tel: (02) 778 3417

    Bal t ic Count r ies :

    Tel: (358) 08872 2100

    Czech Republ ic:

    Tel: 420-2-4743111

    Denmar k:Tel: 45 99 10 00

    Hew lett-P ack ard Sales an d Se rvice Offices (contd)

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    36/38

    Finland:

    Tel: (90) 88 721

    France:

    Tel: (0)1 69.82.60 .60

    Ger many:

    Tel: (0180) 532 62-33

    Greece:

    Tel: 30-1-7264045

    Hungary:

    Tel: 36-1-4618219

    I re land:

    Tel: (01) 284 4633

    Israel:Tel: 972-3-5380333

    I taly:

    Tel: 02 - 92 122 241

    Nether lands:

    Tel: (020) 547 6669

    Norway:

    Tel: (22) 73 57 50

    Poland:

    Tel: 48-22-6087700

    Por tugal:

    Tel: (11) 482 85 00

    Russia:

    Tel: (7/095) 928 6885

    Fax: (7/095) 916 9844

    South Afr ica :

    Tel: 27-22-8061000

    S p a i n :

    Tel: (34) 1 631 1323

    S w e d e n :

    Tel: (08) 444 22 77

    S w i t z e r l a n d :

    Tel: (01) 735 7111

    Turkey:

    Tel: 90-212-2245925

    Uni ted K ingdom:Tel: (01344) 366 666

    For count r ies in Europ e/Midd le East

    an d Afr ica not l i s ted , conta ct :

    Hewlett-Packard

    Intern ational Sa les Eu rope

    Geneva, Switzerlan dTel: +41-22-780-4111

    Fax: +41-22-780-4770

    Latin Ame rica:Hewlett-Packard

    Lat in American Region Hea dquar ters

    5200 Blue La goon Drive

    9th FloorMiam i, Florida 33126

    U.S.A.

    Tel: (305) 267-4245

    Tel: (305) 267-4220

    Fax: (305) 267-4288

    United States:Hewlett-Packard Company

    Test and Measurement Organization

    5301 Stevens Creek Blvd.

    Bldg. 51L-SC

    Santa Clara, CA 95052-8059

    Tel: 1 800 452 4844

    About This Edition

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    37/38

    This is th e 1st edition

    of the 37717-90401

    manu al. It documents

    th e product a s ofMarch 1998. Edition

    dates are as follows:

    1st E dition, Mar ch

    1998

    Copyright H ewlett-

    Packard Ltd. 1998. All

    rights reserved.Reproduction,

    ada ption, or

    tra nslation without

    prior written

    permission is

    prohibited, except as

    allowed under th e

    copyright laws.

  • 8/8/2019 Agilent 37717C Quick Start Guide ZD6KXDJiayjB

    38/38

    Printed in U.K. 03/9837717-90401

    In This Boo k

    This bookdemonstra tes the basicopera tion of th e instru ment . It tells

    you h ow to select th e displays t ha t

    you want and how to use them to

    modify the inst ru ment fun ctions.

    This guide also tells you about t he

    front panel key functions, the

    indicat ors an d t he conn ectors.


Recommended