Date post: | 18-Dec-2015 |
Category: |
Documents |
Upload: | brendan-manning |
View: | 216 times |
Download: | 2 times |
AHMAD RAZALI BIN ISHAKDEPARTMENT OF ENVIRONMENTAL HEALTHFACULTY OF HEALTH SCIENCESUITM PUNCAK ALAM
Sample Preparation for inorganic trace analysis
Lecture 2
Introduction
Analysis for metals in solids-2 different approach
1. Direct analysis of solid-X-ray florescence (self study-assignment)
2. After decomposition
Decomposition techniques
involves liberation of analyte (metal) of interest from interfering matrix
Using a reagent (mineral/oxidizing acids or fusion or flux) And/or Heat
Problem- risk of contamination and loss of analytes
Dry ashing
The simplest of all decomposition systems involves the heating of the samples in porcelain crucible in a muffle furnace in the presence of air at 400-800C
After decomposition, the residue is dissolved in acid and transferred to a volumetric flask prior to analysis.
Allow organic matter to be destroyed.May lead to the loss of volatile elements (Hg,
Cd, Ca, As, Sb, Cr and Cu)
Cont..
Disadvantages of this method: Loss due to volatilization Resistance to ashing by some materials Difficult dissolution of ashed materials High risk of contamination
It has largely been replace by wet ashing
Wet digestion (Acid digestion)
The use of mineral or oxidizing acids and an external heat sources to decompose the sample matrix.
The choice of an individual acids is dependent upon the nature of the matrix to be decomposed
Once the choice of acid is made the sample is placed into an appropriate vessel for decomposition stage
Vessel- carried out in open glass vessels(beakers or boiling tubes) using hotplate (in FSK) or multiple sample digester
The US EPA method for acid digestion of sediments, sludges and soils are outlined in figure 1
The digestion of food stuffs can be carried out in a similar manner
A typical procedure for digestion of foodstuffs e.g. cereals, meats, fish and vegetable for determination of total metal content (cadmium,cooper,iron, lead and zinc) in figure 2
Microwave digestion
An alternative approach to conventional heating involves the use of microwave heating
Advances in technology by a variety of manufacturers means that today there are two types of microwave heating systems commercially available : open-focused and closed vessel system.
Introduction
Analysis of liquid samples for metals-required no sample pre-treatment-just a simple filtration (0.2 um)of the sample to remove particulates prior to introduction into chosen instrument.
However, reality is often very different and even most sensitive of analytical technique (e.g. ICP-MS) may require some additional sample pre-treatment; separation or pre-concentration
Pretreatment/pre-concentration-potential contamination-great care required
Liquid-liquid extraction
Addition of a suitable chelating agent to the water samples to form metal complex
Will effectively partition into an immiscible organic solvent
Metal present in a large volume of sample water is effectively and quantitatively transferred into a small volume of organic solvent.
The important variables in LLE are as follows:
a) Choice of chelating agentb) Choice of organic solventc) pH of the aqueous sampleThe most commonly used chelating agent in
AAS is Ammonium pyrrolidine dithiocarbamate (APDC). This reagent can be directly extracted with methyl isobutyl ketone (MIBK) as the organic solvent.
AHMAD RAZALI BIN ISHAKDEPARTMENT OF ENVIRONMENTAL HEALTHFACULTY OF HEALTH SCIENCESUITM PUNCAK ALAM
Sample preparation for organic analysis
Lecture 3
Introduction
New instrumental approaches-led to development -speed of extraction, reduction in organic solvent consumption and introduction of automation.
However, this instrumental approaches-higher price tag than the conventional.
Extraction of env. Pollutant from solid or semi solid matrices can be divided into several categories based on the method of extraction, mode of heating, and presence or not of some type of agitation.
Types of extraction-Solid
Soxhlet extractionShake flask extractionUltrasonic extractionSupercritical Fluid Extraction (SFE)Microwave assisted extractionPressurized Fluid ExtractionMatrix solid phase dispersion
Soxhlet Extraction
The basis of soxhlet extraction apparatus consist of a solvent reservoir, and extraction body, a heat sources (e.g. isomantle) and a water-cooled reflux condenser
A soxhlet uses a range of organic solvent to remove organic compounds, primarily from solid matrices
The solid sample (e.g. 10 g soil) and a similar mass of anhydrous sodium sulfate are placed in the porous thimble (cellulose) which in turn is located in the inner tube of Soxhlet apparatus
The apparatus is then fitted to a round- bottom flask of appropriate volume containing organic solvent of choice and to reflux condenser.
The solvent is then boiled gently-The solvent vapor passes up through the tube is condensed by the reflux condenser and the condensed solvent falls into the thimble and slowly fills the body of soxhlet apparatus
When the solvent reaches the top of the tube, it syphons over into the round-bottomed flask the organic solvent containing the analyte extracted from the sample in the thimble. This solvent is then said to have completed one cycle.
The whole process is repeated frequently until the pre-set extraction time is reached.
As the extracted analyte will normally have higher boiling point than the solvent, it is preferentially retained in the flask and fresh solvent re-circulates
Shake Flask Extraction
Conventional LLE in the form of shake flask extraction is carried out by placing samples (e.g. soil) into a suitable glass container, adding a suitable organic solvent and the agitating or shaking
Ultrasonic extraction
Sonication involves the use of sound waves to agitate a sample immersed in an organic solvent-using sonic probe or sonic bath
The sample is placed in suitable glass container and enough organic solvent is then added to cover the sample.
The system is then sonicated for a short period typically 3 min using sonic bath or probe
After extraction, the solvent containing the analyte is separated by centrifugation and/or filtration and fresh solvent added.
The whole process is repeated three times and all of the solvent extract are then combined.
Types of extraction-Liquid
Liquid Liquid extraction (LLE)Solid phase extraction (SPE)Solid Phase Microextraction (SPME)
Liquid-Liquid Extraction
The sample is distributed/partitioned into two immiscible solvent which analyte and matrix have different solubility
Advantage-wide availability of pure solvent, low cost apparatus
Solid phase extraction
Liquid-solid extractionBringing a liquid sample into contact with a
solid sorbent whereby the analyte is selectively adsorbed onto the surface of solid phase.
The latter is then separated from solution and other solvents are added.
Solid Phase extraction
The first solvent-wash to remove possible contaminant
Then, Liquid sample bring into contact with a solid phase/sorbent whereby analyte is selectively adsorbed onto the surface of solid phase.
The analyte then separated from the solid phase by eluting solvent.
This solvent is then collected for analysis.
Solid Phase Micro Extraction (SPME)
The process whereby an analyte is adsorbed onto the surface of a coated silica fiber as a method of concentration.
This is follow by desorption of the analyte into a suitable instrument for separation and quantification
Introduction
Volatile compounds in the atmosphere, workplace and on industrial sites need to be monitored with regard to safety consideration
This VOC, can be trapped either on a solid support material (for thermal desorption) or liberated from water sample and then trapped (e.g. via purge and trap) prior to analysis.