Contamination control, healthcare safety
Air qualitySurface disinfectionFor healthcare environments
AIR
qual
ity
SURF
ACE
disi
nfec
tion
We provide our customers with expertise, audit and smart solutions to control contamination in hospitals and critical care areas.
Cost effective solutionsModular and mobile, they can be installed in existing buildings to achieve best air quality standards anywhere anytime on demand without any additional construction cost.
Easy to maintain - on site- with no loss of activity and revenue.
Low energy consumer.
The airinspace™ portfolio addresses each situation providing a specific and dedicated solution from particles removal to complete patient isolation.
Comprehensive portfolio
BIOCAIR™
IMMUNAIR™
PLASMAIR™
HEPA
NO PROTECTION
An expert and trustworthy partner
Our products and services help hospital customers… Protect immuno-compromised patients within air quality in high risk areas
Isolate infected patients to avoid any cross-contamination and medical staff infection
Support ward refurbishment with mobile and quick solutions (no extra-work required)
Retrofit or reinforce existing air treatment facility
Audit: our team comes from a background of pharmaceutical and clean rooms industries. They are experts in air treatment and can help you make complete analysis of existing installations. They can provide you with efficient, cost effective and simple solutions.
Installation: once machines are delivered, our technical team is available to support technical and medical staff with product installation and startup assistance. We provide Functional Qualification (QF) on site and fully train end users.
Maintenance and after sales service: maintenance is easy and cost effective. We offer several options and our contracts are valid during the whole life-cycle of the products worldwide.
Warranty: airinspace ™ offers 1 year warranty on parts and labor woldwide (modules and filters not included).
Service and Quality: we are dedicated to customer satisfaction and ISO9001 certified.
The reference in air purification and surface disinfection Derived from Space research program, our products have been the subject of numerous peer reviewed scientific publications*. Our R&D team has over 15 years of experience and our application engineers take special care to ensure peak performances and patient’s comfort through ergonomic design. We supply 48 countries worldwide through our own direct sales force and a first class distributors with highly trained sales staff capable to provide full service to our final customers. Technical service is always on hand to help install products and train end users. In addition to perform maintenance, they also manage trouble shooting worldwide.
* Bibliography available on request.
Example of microorganisms:Aspergillus fumigatus.M.E.R.S. virus.Mycobacterium tuberculosis.
Protected environments
The Coanda effect is the result of an air stream being attracted toward a nearby surface due to air velocities. This airflow pattern enables a continuous and optimized mixing of the room’s air volume.
COANDA EFFECT
SURFACE disinfection
Example of microorganisms:
Mycobacterium.Clostridium difficile. Aspergillus fumigatus.
User friendly touch screen. Possible to load data on USB stick.
Intuitive touch screen. Printer for easy traceability.
AIR quality
Performance: ISO 6 to ISO 7
Airflow range: up to 2 500 m3/h
Filtration: From H14 to U15
Average sound level: Very silent: 39 dB(A)
High capacity, efficient, silent No release of chemical compound
User friendly
Touch screen for easy access to menus
Compact for small room For room up to 50 m3
Small footprint
Very mobile
Performance: ISO 7
Air flow range: up to 850 m3/h
Average sound level: 41 dB(A)
Air decontamination ceiling system Remote control
Optional Light servicing
Coanda effect to optimize air circulation
Mobile air treatment systemsHEPA-MD ™ TECHNOLOGY, THE REFERENCE IN HAEMATOLOGY & TRANSPLANT UNIT.
The reactor kills microorganisms (bacteria, virus, fungi and spores), removes particles, VOCs and reduces ozone level in the environment.
Stage 1Destruction of micro-organisms by plasmerisation.
Stage 2HEPA filtration.
Stage 3Molecular conversion
to remove oxidative components.
Stage 4Molecular adsorption of volatile polluants.
High filtration efficiency systems for medium risk patients and general ward applications.
Performance: ISO 9 to ISO 7
Air flow range: up to 2 500 m3/h
Filtration: from H14 to U15
Average sound level: Silent: 40 dB(A)
High capacity and fast particle removal
Ultra fast filtration performance in less than 10 min
Excellent mobility
Airborne pollutants adsorption systems to remove toxic compounds from ambient air.
Rapid elimination of acetic and peracetic acid (APA) and hydrogen peroxide ( H 2 O 2 ) Quick decontamination of room Shorten vent times after surface bio disinfection
Removal of strong oxidant agents
ACH: from 10 to 20 vol/h, airflow range up to 1 800 m3/ h
Average sound level: 20 dB(A)
Exceed all requirements of the most stringent standard NF-T 72-281
Quick: Efficiency up to 99,999984% in 30 min. (Bacteria, Virus, Fungi & Yeast, Spores, Tuberculosis & Mycobacteria)
Cost effective
Small, light and ergonomic
Twice fast as RHEA Compact. Huge capacity with 2 drums of disinfectant Accurate control of vaporized solution dispensedPossible connection to eCHEM for automatic start of vent process Integral printer Data download on USB stick or cableUser friendly touch screenAdditional space for mask (PPE) and peroxide detector
No additional adjuvants (Ag, formaldehydes essential oils...)
No solid residue after treatment
Mixture of APA and H2O2used at room temperature
Reduces bio contamination load on all exposed surfaces by up to log7. A highly effective process for infectious outbreak containment. Used for disinfection of AIIRs and preparation of protected environ- ments for immuno-compromised patients.
The airinspace ™ process HPV PA. Multi range biocide using hydrogen peroxide ( H 2 O 2 ) boosted by peractic acid ( PAA )
Mobile or stationary protective environments to be used with PLASMAIR™ units, easy to install in patient room.
Ca
tch & BurnTechnology
Large and intuitive touch screen. Automatic shift day to night.
A question? a request?
contact us: +33 1 30 07 01 09
or email us:[email protected]
HEPA-MD™ technology is validated by international recognized laboratories.
Performance: ISO 5
Tailored size and spaceto suit any room layout
Automatic sliding door with controlled leak rate
Cleanroom walls
Assembly within 3 days
Friendly user interface
Modular isolation room for Airborne Infectious Isolation Room (AIIR) or protective equipment application
Deployable plenum to protect immunocompromised patients in BMT transplant, oncology and immunology units
Performance: ISO 5 under the unidirectional airflow system
Light servicing
Comfortable patient area
Easy access for medical staff
Fixed or mobile variants
Optional flat screen TV
Example of a complete decontamination cycle in an unventilated room of 50 m 3.
Decontamination of a 35 m 3 room from ISO 9 to ISO 7 in 10 minutes.Log reduction of particle load in 10 minutes.24 air changes per hour (ACH ).
Performance: ISO 7
Air flow range: up to 1 200 m 3/h
Filtration: H14
Average sound level: 45 dB(A)
Small footprint
Easily transportable
Compact filtration system Removal of airborne Volatile Organic Components (VOC) in In Vitro Fertilization lab
Quick removal of aldehydes based agents (ex: formaldehydes)
ACH: from 10 to 20 vol/h,airflow range up to 1800 m3/h
Average sound level: 32 dB(A)
X-CID
RHEATitan
RHEACompact
IMMUNAIR™BIOCAIR™
PLASMAIR™
C2010PLASMAIR™
SentinelPLASMAIR™
Guardian
HEPASentinel
HEPAGuardian
eCHEM OX
Sentinel
eCHEM VOC
Sentinel
Performance:ISO 7
Airflow range: up to 800 m3/h
Average sound level:Virtually silent: 43 dB(A)
airinspace ™14, rue Jean Monnet78990 ÉlancourtFrance
T. +33 (0)1 30 07 01 01F. +33 (0)1 30 07 01 [email protected]
www.airinspace.com
© a
irins
pace
™ 2
016
- ai
rinsp
ace™
, BIO
CAIR
™, I
MM
UNAI
R™ H
EPA-
MD™
and
PLA
SMAI
R ™ ar
e re
gist
ered
trad
emar
ks -
PLA
SMAI
R Gu
ardi
an, R
HEA
Com
pact
and
RHE
A Ti
tan
are
regi
ster
ed m
odel
s -
DOC
GENE
Ed
03 2
016 /
11 -
EN
- Cr
eatio
n: T
hink
ad c
omm
unica
tion