EEDEN14-200 Air Conditioners Introduction Technical Data
Transcript
Page 1: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

E E D E N 1 4 - 2 0 0

Air Conditioners

I nt roduc t ion

Technical Data

Page 2: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

E E D E N 1 4 - 2 0 0

Air Conditioners

I nt roduc t ion

Technical Data

Page 3: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

• VRV Systems • Introduction 1

• Introduction

1 Indoor unit range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2 Ventilation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3 Biddle air curtain range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

4 Hydrobox range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

5 Network solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

6 Possible outdoor units using R-410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Outdoor unit range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

VRV Heat Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

VRV Heat Recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Replacement VRV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

VRV-WIII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Indoor unit capacity index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

7 Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Indoor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Biddle air curtains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Ventilation units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Hydroboxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Outdoor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

TABLE OF CONTENTSI Introduction

Page 4: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

• Introduction

• VRV Systems • Introduction2

I1

1 Indoor unit rangeVRV air conditioning brings summer freshness and winter warmth to offices, hotels, department stores and many other commercial premises. It enhances the indoor environment and creates a basis for increased business prosperity and whatever the air conditioning requirement, a Daikin indoor unit will provide the answer.

NOTES

1 Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.

2 Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m

3 Optional

4 Not connectable to VRV III-S

Capacity

Type ModelProduct

name15 20 25 32 40 50 63 71 80 100 125 140 200 250

CEI

LIN

G M

OU

NTE

D C

ASS

ETTE

Round flow cassetteautocleaning function3

Presence & floor sensor3FXFQ-A

Fully flat cassettePresence & floor sensor3 FXZQ-A

2-way blowceiling mounted cassette

FXCQ-A

Ceiling mountedcorner cassette FXKQ-MA

CO

NC

EALE

D C

EILI

NG

Small concealed ceiling unit FXDQ-M9

Slim concealed ceiling unit FXDQ-A

Concealed ceiling unitwith inverter driven fan

FXSQ-P

Concealed ceiling unitwith inverter driven fan FXMQ-P7

Large concealedceiling unit

FXMQ-MA4

WAL

L

MO

UNTE

D

Wall mounted unit FXAQ-P

CEIL

ING

SUS

PEND

ED

Ceiling suspended unit FXHQ-A

4-way blow ceilingsuspended unit

FXUQ-MA

FLO

OR

STA

ND

ING

Floor standing unit FXLQ-P

Concealedfloor standing unit

FXNQ-P

Cooling capacity (kW)1 1.7 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 22.4 28.0

Heating capacity (kW)2 1.9 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0 25.0 31.5

Page 5: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

• VRV Systems • Introduction 3

• Introduction

3

I1

1 Indoor unit range

NOTES

1 Decoration panel BYCQ140CG + BRC 1E51A needed

2 To connect RA indoor units a BP box is required

CapacityConnectableoutdoor unit

Type ModelProduct

name15 20 25 35 42 50 60 71

RYYQ-TRXYQ-T

RXYSQ-P8V1RXYSQ-P8Y1

CEI

LIN

G M

OU

NTE

D

CA

SSET

TE

Round flow cassette(incl. autoclean function1)

FCQG-F Fully flat cassette FFQ-C

CO

NC

EALE

D C

EILI

NG Small concealed ceiling unit FDBQ-B

Slim concealed ceiling unit FDXS-F(9) Concealed ceiling unitwith inverter driven fan FBQ-C

WA

LL M

OU

NTE

D

Daikin EmuraWall mounted unit

FTXG-LW/LS Wall mounted unit

CTXS-KFTXS-K

Wall mounted unit FTXS-G

CEILI

NG

SUSP

ENDE

D

Ceiling suspended unit FHQ-C

FLO

OR

STA

ND

ING

Nexura floor standing unit FVXG-K Floor standing unit FVXS-F

Flexi type unit FLXS-B(9)

Page 6: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

• Introduction

• VRV Systems • Introduction4

I2

2 Ventilation range

NOTES

1 Not connectable to VRVIII-S (RXYSQ-P8V1, RXYSQ-P8Y1)

2 Air flow rate is a calculated indication only, based on the following values: heating capacity EKEXV-kit * 200m³/h

3 For more information on Daikin air handling units refer to your local dealer

Air flow rate (m3/h)

TypeProduct

nameModel 0 200 400 600 800 1,000 1,500 2,000 4,000 6,000 8,000

VAM-FA/FB 1 Ventilation

HEAT RECLAIM

VENTILATIONVKM-GB

1 Ventilation3 Pre conditioning

VKM-GBM1 Ventilation2 Humidification3 Pre conditioning

OUTDOOR AIR PROCESSING UNIT1 FXMQ-MF

1 Ventilation3 Pre conditioning

VRV AIR HANDLING

APPLICATIONS2EKEXV-kit

1 Ventilation3 Pre conditioning

Ventilation: provision of fresh air

Pre conditioning: cooling or heating of incoming fresh air to maintain aconsistent temperature for maximum comfort

Humidification: optimise the balance between indoor and outdoor humidity

Page 7: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

• VRV Systems • Introduction 5

• Introduction

3

I3

3 Biddle air curtain range

4 Hydrobox range

NOTES

1 Only connectable to RYYQ-T / RXYQ-T

2 Only connectable to REYAQ-P

5 Network solutions

NOTES

1 Interface for Lonworks networks

2 Interface for BACnet networks

Type Product name

BIDDLE AIR CURTAIN FREE HANGING CYV S/M/L-DK-F

BIDDLE AIR CURTAIN CASSETTE CYV S/M/L-DK-C

BIDDLE AIR CURTAIN RECESSED CYV S/M/L-DK-R

Biddle air curtain range for VRV

Capacity

Type Product nameleaving water

temperature range80 125

LOW TEMPERATURE HYDROBOX 1 HXY-A 5°C - 45°C

HIGH TEMPERATURE HYDROBOX 2 HXHD-A 25°C - 80°C

Control Monitoring Options Other control functions

Bas

ic c

ontr

ol fu

nctio

ns:

ON

/OFF

, tem

p. S

ettin

g, a

ir flo

w s

ettin

gs

Aut

omat

ic c

hang

eove

r

Wee

kly

sche

dule

con

trol

Fire

em

erge

ncy

stop

con

trol

Bas

ic m

onito

ring

func

tions

:O

N/O

FF s

tatu

s, o

pera

tion

mod

e, s

et p

oint

tem

p.

Indi

catio

n fil

ter r

epla

cem

ent

Mal

func

tion

code

Pass

wor

d se

curit

y

Touc

h sc

reen

Dai

ly/m

onth

ly/y

early

repo

rts

Con

trol

via

GSM

Gra

phic

al re

port

Visu

alis

atio

n

Ppd

Web

acc

es &

con

trol

Http

opt

ion

Pre

cool

ing

/ hea

ting

0°�

Bet

wee

n co

olin

g &

hea

ting

Slid

ing

t° a

void

s ov

erco

olin

g vi

a se

nsor

Free

coo

ling

chan

geov

er

AC

NSS

con

nect

ion

air c

ondi

tioni

ng n

etw

ork

serv

ice

syst

em

Sche

dulin

g pr

eset

s (p

rogr

ams)

Use

r frie

ndlin

ess

Max

. Ind

oors

gro

ups

DTA113B51 + + 4

INTELLIGENT TOUCH CONTROLLER

++ 8 +++ 64

INTELLIGENT TOUCH MANAGER

+++ 100 +++ 512

DMS-IF1 N/A N/A 64

BACNET2 N/A N/A 4x64

Door height (m)

Favourableex: covered shopping mall orrevolving door entrance

Normalex: little direct wind, no opposite open doors, building with ground floor only

Unfavourableex: location at a corner orsquare, multiple floorsand / or open stairwell

Installation condition

4

3

2

1

2.3m2.5m

3.0m

2.15m2.4m

2.75m

2.0m2.3m

2.5m

Page 8: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

• Introduction

• VRV Systems • Introduction6

I6

6 Possible outdoor units using R-410A

6 - 1 Outdoor unit range

Single unit

Multi combination

NOTES

*1 Not a standard combination (free combination)

: component is connectable

x : component is not connectableNot all components are connectable at the same time to one outdoor unit.Refer to the engineering databook for more information.

Capacity (HP)

System Type Product name

4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54

Indo

orun

it

Vent

ilatio

n

Air

curt

ain

Hyd

robo

xco

nnec

tion

Con

trol

syst

ems

AIR

CO

OL

ED

HEA

T PU

MP

RYYQ-T Heat pump with

continuous heating

x *1 *1 *1

RXYQ-T Heat pump without continuous heating

x *1 *1 *1

RXYSQ-P8V1 (Single phase)RXYSQ-P8Y1 (Three phase)

x x x

RTSYQ-PA Heat pump

optimised for heating

x x x

RXYCQ-A x x x x x

HEA

TREC

OVE

RY

REYQ-P8/P9 Small footprint combination

x x x

REYHQ-P High COP combination

x x x

REYAQ-Pfor connection with

heating only hydrobox

x x

WA

TE

R

CO

OL

ED

HEA

T R

ECO

VER

Y H

EAT

PUM

P

RWEYQ-T x x

Capacity (HP)

System Type Product name 4 5 8 10 12 13 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54

Capacity class 140 280 360 460 500 540 636 712 744 816 848

AIR

CO

OL

ED

REP

LAC

EMEN

T VR

V H

EAT

REC

OVE

RY

- H

EAT

PUM

P

RXYQQ-TVRVIV - Q - H/P x x x

*1 *1 *1

RQCEQ-PVRVIII-Q - H/R

VRV

type

indo

or u

nits

(suc

h as

FXS

Q)

Res

iden

tial t

ype

indo

or u

nits

(suc

h as

Dai

kin

Emur

a)

Hea

t Rec

laim

ven

tilat

ion

(suc

h as

VAM

)Fr

esh

air i

ndoo

r uni

ts (s

uch

as F

XMQ

-MF)

AHU

con

nect

ion

kit (

such

as

EKEX

V)

Bidd

le A

ir cu

rtain

for V

RV

(CYV

)

Low

tem

pera

ture

hyd

robo

x fo

r VR

VH

igh

tem

pera

ture

hyd

robo

x fo

r VR

VIn

divi

dual

con

trol (

such

as

BRC

)C

entra

lised

con

trol (

such

as

DC

S3*/D

ST)

Net

wor

k so

lutio

ns (s

uch

as D

CS6

*/DAM

/DM

S)

22

-Q

Page 9: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

• VRV Systems • Introduction 7

• Introduction

3

I6

6 Possible outdoor units using R-410A

6 - 2 VRV Heat Pump

6 - 2 - 1 Small footprint combination

NOTES

1 VRV IV offers free combinations, the above combination is only one of the possibilities.

2 Actual number of connectable indoor units depends on the indoor unit type (VRV indoor, Hydrobox, RA indoor, etc.) and the connection ratio restriction for the system (50% <= CR <= 130%)

6 - 2 - 2 VRVIII-C Heat pump optimized for heating

VRV IV heat pump Possible combination1 N° of outdoor units N° of compressorsN° of connectable indoor

units Minimum capacity index Maximum capacity index

RYYQ8T / RXYQ8T RYYQ8T / RXYQ8T 1 1 max 172 100 260

RYYQ10T / RXYQ10T RYYQ10T / RXYQ10T 1 1 max 212 125 325

RYYQ12T / RXYQ12T RYYQ12T / RXYQ12T 1 1 max 262 150 390

RYYQ14T / RXYQ14T RYYQ14T / RXYQ14T 1 2 max 302 175 455

RYYQ16T / RXYQ16T RYYQ16T / RXYQ16T 1 2 max 342 200 520

RYYQ18T / RXYQ18T RYYQ18T / RXYQ18T 1 2 max 392 225 585

RYYQ20T / RXYQ20T RYYQ20T / RXYQ20T 2 2 max 43 2 250 650

RYYQ22T / RXYQ22TRYMQ10T + RYMQ12T / RXYQ10T + RXYQ12T 2 2 max 472 275 715

RYYQ24T / RXYQ24T RYMQ8T + RYMQ16T / RXYQ8T + RXYQ16T

2 3 max 522 300 780

RYYQ26T / RXYQ26TRYMQ12T + RYMQ14T / RXYQ12T + RXYQ14T

2 3 max 562 325 845

RYYQ28T / RXYQ28TRYMQ12T + RYMQ16T / RXYQ12T + RXYQ16T 2 3 max 60 2 350 910

RYYQ30T / RXYQ30T RYMQ12T + RYMQ18T / RXYQ12T + RXYQ18T

2 3 max 64 2 375 975

RYYQ32T / RXYQ32TRYMQ16T + RYMQ16T / RXYQ16T + RXYQ16T

2 4 max 64 2 400 1,040

RYYQ34T / RXYQ34TRYMQ16T + RYMQ18T / RXYQ16T + RXYQ18T 2 4 max 64 2 425 1,105

RYYQ36T / RXYQ36T RYMQ16T + RYMQ20T / RXYQ16T + RXYQ20T

2 4 max 64 2 450 1,170

RYYQ38T / RXYQ38TRYMQ8T + RYMQ10T + RYMQ20T / RXYQ8T + RXYQ10T + RXYQ20T

3 4 max 64 2 475 1,235

RYYQ40T / RXYQ40TRYMQ10T + RYMQ12T + RYMQ18T / RXYQ10T + RXYQ12T + RXYQ18T 3 4 max 64 2 500 1,300

RYYQ42T / RXYQ42T RYMQ10T + RYMQ16T + RYMQ16T / RXYQ10T + RXYQ16T + RXYQ16T

3 5 max 64 2 525 1,365

RYYQ44T / RXYQ44TRYMQ12T + RYMQ16T + RYMQ16T / RXYQ12T + RXYQ16T + RXYQ16T

3 5 max 64 2 550 1,430

RYYQ46T / RXYQ46TRYMQ14T + RYMQ16T + RYMQ16T / RXYQ14T + RXYQ16T + RXYQ16T 3 6 max 64 2 575 1,495

RYYQ48T / RXYQ48T RYMQ16T + RYMQ16T + RYMQ16T / RXYQ16T + RXYQ16T + RXYQ16T

3 6 max 64 2 600 1,560

RYYQ50T / RXYQ50TRYMQ16T + RYMQ16T + RYMQ18T / RXYQ16T + RXYQ16T + RXYQ18T

3 6 max 64 2 625 1,625

RYYQ52T / RXYQ52TRYMQ16T + RYMQ18T + RYMQ18T / RXYQ16T + RXYQ18T + RXYQ18T 3 6 max 64 2 650 1,690

RYYQ54T / RXYQ54T RYMQ18T + RYMQ18T + RYMQ18T / RXYQ18T + RXYQ18T + RXYQ18T

3 6 max 64 2 675 1,755

VRVIII heat pump Fixed combinations N° of outdoors N° of compressors N° of connectable indoor units

Minimum capacity index Maximum capacity index

RTSYQ10PA RTSQ10PA + BTSQ20P 1 + function unit 2+1 21 125 325

RTSYQ14PA RTSQ14PA + BTSQ20P 1 + function unit 3+1 30 175 455

RTSYQ16PA RTSQ16PA + BTSQ20P 1 + function unit 3+1 34 200 520

RTSYQ20PA RTSQ8PA + RTSQ12PA + BTSQ20P 2 + function unit 3+1 43 250 650

Page 10: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

• Introduction

• VRV Systems • Introduction8

I6

6 Possible outdoor units using R-410A

6 - 2 VRV Heat Pump

6 - 2 - 3 VRVIII-S

6 - 2 - 4 VRV Classic

VRVIII-S N° of outdoors N° of compressorsN° of connectable indoor

unitsMinimum capacity index Maximum capacity index

RXYSQ4P8V1/RXYSQ4P8Y1 1 1 8 50 130

RXYSQ5P8V1/RXYSQ5P8Y1 1 1 10 62.5 162.5

RXYSQ6P8V1/RXYSQ6P8Y1 1 1 13 75 195

VRV Classic N° of outdoor units N° of compressors N° of connectable indoor units

Minimum capacity index Maximum capacity index

RXYCQ8A 1 1 16 100 240

RXYCQ10A 1 1 20 125 300

RXYCQ12A 1 2 24 150 360

RXYCQ14A 1 2 28 175 420

RXYCQ16A 1 3 32 200 480

RXYCQ18A 1 3 36 225 540

RXYCQ20A 1 3 40 250 600

Page 11: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

• VRV Systems • Introduction 9

• Introduction

3

I6

6 Possible outdoor units using R-410A

6 - 3 VRV Heat Recovery

6 - 3 - 1 Small footprint combination

6 - 3 - 2 High COP combination

6 - 3 - 3 With connection to heating only hydrobox

VRVIII heat reovery Fixed combinations N° of outdoors N° of compressors N° of connectable indoor units

Minimum capacity index Maximum capacity index

REYQ8P9 REYQ8P9 1 2 17 100 260

REYQ10P8 REYQ10P8 1 2 21 125 325

REYQ12P9 REYQ12P9 1 2 26 150 390

REYQ14P8 REYQ14P8 1 2 30 175 455

REYQ16P8 REYQ16P8 1 2 34 200 520

REYQ18P9 REMQ8P9 + REMQ10P8 2 3 39 225 585

REYQ20P9 REMQ8P9 + REMQ12P8 2 3 43 250 650

REYQ22P8 REMQ10P 8+ REMQ12P8 2 4 47 275 715

REYQ24P8 REMQ12P8 + REMQ12P8 2 4 52 300 780

REYQ26P8 REMQ10P8 + REMQ16P8 2 5 56 325 845

REYQ28P8 REMQ12P8 + REMQ16P8 2 5 60 350 910

REYQ30P8 REMQ14P8 + REMQ16P8 2 6 64 375 975

REYQ32P8 REMQ16P8 + REMQ16P8 2 6 64 400 1,040

REYQ34P9 REMQ8P9 + REMQ10P8 + REMQ16P8 3 6 64 425 1,105

REYQ36P9 REMQ8P9 + REMQ12P8 + REMQ16P8 3 6 64 450 1,170

REYQ38P8 REMQ10P8 + REMQ12P8 + REMQ16P8 3 7 64 475 1,235

REYQ40P8 REMQ12P8 + REMQ12P8 + REMQ16P8 3 8 64 500 1,300

REYQ42P8 REMQ10P8 + REMQ16P8 + REMQ16P8 3 8 64 525 1,365

REYQ44P8 REMQ12P8 + REMQ16P8 + REMQ16P8 3 8 64 550 1,430

REYQ46P8 REMQ14P8 + REMQ16P8 + REMQ16P8 3 8 64 575 1,495

REYQ48P8 REMQ16P8 + REMQ16P8 + REMQ16P8 3 9 64 600 1,560

VRVIII heat reovery Fixed combinations N° of outdoors N° of compressorsN° of connectable indoor

units Minimum capacity index Maximum capacity index

REYHQ16P REMQ8P9 + REMQ8P9 2 2 34 200 520

REYHQ20P REMQ8P9 + REMHQ12P8 2 3 43 225 585

REYHQ22P REMQ10P8 + REMHQ12P8 2 4 47 250 650

REYHQ24P REMQ12P8 + REMHQ12P8 2 4 52 275 715

VRVIII heat reovery N° of outdoors N° of compressors N° of connectable indoor units Minimum capacity index Maximum capacity index

REYAQ10P 1 2 21 125 325

REYAQ12P 1 2 26 150 390

REYAQ14P 1 2 30 175 455

REYAQ16P 1 2 34 200 520

Page 12: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

• Introduction

• VRV Systems • Introduction10

I6

6 Possible outdoor units using R-410A

6 - 4 Replacement VRV

1 Actual number of connectable indoor units depends on the indoor unit type (VRV indoor, Hydrobox, RA indoor, etc.) and the connection ratio restriction for the system (50% <= CR <= 130%)

Replacement VRV - Heat recovery

Fixed combinationsCapacity range

Cooling capacity

Heating capacity N° of

outdoorsN° of

compressors

N° of connectable indor units

Indoor unit combination ratio

HP kW kW 130% 120% 110% 100% 90% 80% 70% 60% 50%

RQCEQ280P RQEQ140P + RQEQ140P 10 28.0 32.0 2 2 21 364 336 308 280 252 224 196 168 140

RQCEQ360P RQEQ180P + RQEQ180P 13 36.0 40.0 2 2 28 468 432 396 360 324 288 252 216 180

RQCEQ460P RQEQ140P + RQEQ140P + RQEQ180P 16 45.0 52.0 3 3 34 598 552 506 460 414 368 322 276 230

RQCEQ500P RQEQ140P + RQEQ180P + RQEQ180P 18 50.0 56.0 3 3 39 650 600 550 500 450 400 350 300 250

RQCEQ540P RQEQ180P + RQEQ180P + RQEQ180P 20 54.0 60.0 3 3 43 702 648 594 540 486 400 378 324 270

RQCEQ636P RQEQ212P + RQEQ212P + RQEQ212P 22 63.6 67.2 3 3 47 827 763 699 636 572 508 445 381 318

RQCEQ712P RQEQ140P + RQEQ180P + RQEQ180P + RQEQ212P 24 71.2 78.4 4 4 52 926 854 783 712 640 569 498 427 356

RQCEQ744P RQEQ140P + RQEQ180P + RQEQ212P + RQEQ212P 26 74.4 80.8 4 4 56 967 892 818 744 669 595 520 446 372

RQCEQ816P RQEQ180P + RQEQ212P + RQEQ212P + RQEQ212P 28 81.6 87.2 4 4 60 1,061 979 897 816 734 652 571 489 408

RQCEQ848P RQEQ212P + RQEQ212P + RQEQ212P + RQEQ212P 30 84.8 89.6 4 4 64 1,102 1,017 932 848 763 678 593 508 424

Replacement VRV

- Heat pumpFixed combinations

Capacity rangeCooling capacity

Heating capacity N° of

outdoorsN° of compressors

N° of connectable indoor units

Indoor unit combination ratio

HP kW kW 130% 120% 110% 100% 90% 80% 70% 60% 50%

RQYQ140P RQYQ140P 5 14.0 16.0 1 1 10 162.5 150 137.5 125 112.5 100 87.5 75 62.5

RXYQQ8T RXYQQ8T 8 22.4 25 1 1 641 260 240 220 200 180 160 140 120 100

RXYQQ10T RXYQQ10T 10 28 31.5 1 1 641 325 300 275 250 225 200 175 150 125

RXYQQ12T RXYQQ12T 12 33.5 37.5 1 1 641 390 360 330 300 270 240 210 180 150

RXYQQ14T RXYQQ14T 14 40 45 1 2 641 455 420 385 350 315 280 245 210 175

RXYQQ16T RXYQQ16T 16 45 50 1 2 641 520 480 440 400 360 320 280 240 200

RXYQQ18T RXYQQ18T 18 50 56 1 2 641 585 540 495 450 405 360 315 270 225

RXYQQ20T RXYQQ20T 20 56 63 1 2 641 650 600 550 500 450 400 350 300 250

RXYQQ22T RXYQQ10T + RXYQQ12T 22 61.5 69 2 2 641 715 660 605 550 495 440 385 330 275

RXYQQ24T RXYQQ8T+RXYQQ16T 24 67.4 75 2 3 641 780 720 660 600 540 480 420 360 300

RXYQQ26T RXYQQ12T+RXYQQ14T 26 73.5 82.5 2 3 641 845 780 715 650 585 520 455 390 325

RXYQQ28T RXYQQ12T+RXYQQ16T 28 78.5 87.5 2 3 641 910 840 770 700 630 560 490 420 350

RXYQQ30T RXYQQ12T+RXYQQ18T 30 83.5 93.5 2 3 641 975 900 825 750 675 600 525 450 375

RXYQQ32T RXYQQ16T+RXYQQ16T 32 90 100 2 4 641 1,040 960 880 800 720 640 560 480 400

RXYQQ34T RXYQQ16T+RXYQQ18T 34 95 106 2 4 641 1,105 1,020 935 850 765 680 595 510 425

RXYQQ36T RXYQQ16T+RXYQQ20T 36 101 113 2 4 641 1,170 1,080 990 900 810 720 630 540 450

RXYQQ38T RXYQQ8T+RXYQQ10T+RXYQQ20T 38 106 120 3 4 641 1,235 1,140 1,045 950 855 760 665 570 475

RXYQQ40T RXYQQ10T+RXYQQ12T+RXYQQ18T 40 112 125 3 4 641 1,300 1,200 1,100 1,000 900 800 700 600 500

RXYQQ42T RXYQQ10T+RXYQQ16T+RXYQQ16T 42 118 132 3 5 641 1,365 1,260 1,155 1,050 945 840 735 630 525

Page 13: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

• VRV Systems • Introduction 11

• Introduction

3

I6

6 Possible outdoor units using R-410A

6 - 5 VRV-WIII

6 - 5 - 1 Unified standard and geothermal series

6 - 6 Indoor unit capacity index

VRV IV W-seriesheat pump

VRV IV W-seriesheat recovery Fixed combinations N° of outdoors N° of compressors

N° of connectable indoor units

Minimum capacity index

Maximum capacity index

RWEYQ8T RWEYQ8T 1 1 17 100 260

RWEYQ10T RWEYQ10T 1 1 21 125 325

RWEYQ16T RWEYQ8T + RWEYQ8T 2 2 34 200 520

RWEYQ18T RWEYQ8T + RWEYQ10T 2 2 36 225 585

RWEYQ20T RWEYQ10T + RWEYQ10T 2 2 36 250 650

RWEYQ24T RWEYQ8T + RWEYQ8T + RWEYQ8T 3 3 36 300 780

RWEYQ26T RWEYQ8T + RWEYQ8T + RWEYQ10T 3 3 36 325 845

RWEYQ28T RWEYQ8T + RWEYQ10T + RWEYQ10T 3 3 36 350 910

RWEYQ30T RWEYQ10T + RWEYQ10T + RWEYQ10T 3 3 36 375 975

Model 15 20 25 32 40 50 63 71 80 100 125 200 250

Capacity index 15 20 25 31.25 40 50 62.5 71 80 100 125 200 250

Page 14: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

• Introduction

• VRV Systems • Introduction12

I7

7 Nomenclature

7 - 1 Indoor units

F X F Q 40 A VE B

Special series for Europe (CE approved)*

Power supply symbolV1: 1~, 220-240V, 50HzV3: 1~, 230V, 50HzVE: 1~, 220-240V, 50Hz

M/P/A:Indicates major design category7/8/9: Indicates DENV production

Capacity IndicationConversion to horsepower:15: 0.6HP20: 0.8HP25: 1HP32: 1.25HP40: 1.6HP50: 2.0HP63: 2.5HP80: 3.2HP100: 4HP125: 5HP200: 8HP250: 10HP

Indicates the use of R-410A

Model name

F: Roundflow ceiling mounted cassette

Z: 4-way blow ceiling mounted cassette (600x600mm)

C: 2-way blow ceiling mounted cassette

K: Ceiling mounted corner cassette

S: Concealed ceiling unit

D: Concealed ceiling unit (small)

M: Concealed ceiling unit (large)

H: Ceiling suspended unit

A: Wall mounted unit

L: Floor standing unit

LM: Concealed floor standing unit

X: inverter

F: indoor unit

* B is not mandatory for indoor units

Page 15: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

• VRV Systems • Introduction 13

• Introduction

3

I7

7 Nomenclature

7 - 2 Biddle air curtains

CY V S 150 DK 80 F S C

C = controller standard; N = no controller

Color. B = White (RAL6010), S: Grey (RAL 9006)

Installation type: F = Freehanging, C = Cassette, R = Recessed

Capacity class (kW)

Daikin direct expansion

Door width (cm)

Range. S = Small, M = Medium, L = Large

V = connectable to VRV; Q = connectable to ERQ

Biddle air curtain

Page 16: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

• Introduction

• VRV Systems • Introduction14

I7

7 Nomenclature

7 - 3 Ventilation units

7 - 4 Hydroboxes

V A M 500 F B VE

Ventilation

Air

Mounted type

Air flow rate (m3/h)

Major design category

Design category for EC application

Power supply

VE: Single Phase 50 Hz 220-240V,

60 Hz 200V

V K M 50 GB M V1

Ventilation

Outdoor Air Treatment Type

Mounted type

Nominal Air flow rate 50 : 500 m3/h, 80 : 750 m3/h, 100 : 950 m3/h

Major design category

Moisture (M : With Humidifier Elements, nothing : without Humidifier Elements)

Power supplyV1: Single Phase 50 Hz 220-240V,

H X H D 125 A 7 V1 B

Hydrobox

Inverter

H = heating only; Y = heat pump (reversible)

D = incl. domestic hot water; nothing = no domestic hot water possible

Capacity indication Conversion to horsepower: 125: 5HP

Major design category

7/8/9: Indicates DENV production

Power supplyV1: Single Phase 50 Hz 220-240V,

Special series for europe (CE approved)*

*B is not mandatory for indoor units

Page 17: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

• VRV Systems • Introduction 15

• Introduction

3

I7

7 Nomenclature

7 - 5 Outdoor units

RX Y S Q 5 P8 V1 B

Special series for Europe (CE approved)

Power supply symbol:V1 : 1N~, 220-240V, 50Hz

V3: 1N~, 230V, 50Hz

W1: 3N~, 400V, 50Hz

Y1: 3N~, 380-415V, 50Hz

P, P7, T, A: indicates major design category (internal company symbol)

5: 5HP 12:12HP

8: 8HP 14:14HP

10: 10HP 16:16HP etc.

Indicates the use of R-410A

S: small capacityA: connectable to hydroboxesC: 2nd layer VRV (VRV classic)Q: replacement seriesY: heat pump

RE: indicates that this is a HEAT RECOVERY outdoor unit

RX: indicates that this is a HEAT PUMP outdoor unit

RY: indicates that this is a HEAT PUMP CONTINUOUS HEATING outdoor unit

RQ: indicates that this is a R-22 REPLACEMENT outdoor unit

RT: indicates that this is a LOW AMBIENT outdoor unit

RWE: Indicates that this is a WATER COOLED outdoor unit (heat recovery and heat pump)

Page 18: Air Conditioners Technical Data · 2019. 5. 9. · Technical Data. EEDEN14-200 Air Conditioners Introduction Technical Data ... VKM-GBM 1 Ventilation 2 Humidification 3 Pre conditioning

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende EE

DE

N1

4-2

00

_1

• C

D •

10

/13

• C

op

yri

gh

t D

aik

in

Th

e p

rese

nt

pu

blic

ati

on

su

pe

rse

de

s E

ED

EN

13

-20

0

Pre

par

ed

in B

elg

ium

by

Lan

no

o (

ww

w.la

nn

oo

pri

nt.

be

), a

com

pan

y w

ho

se c

on

cern

for

the

en

viro

nm

en

t is

se

t in

th

e E

MA

S an

d IS

O 1

40

01

sys

tem

s.

Re

spo

nsi

ble

Ed

ito

r: D

aik

in E

uro

pe

N.V

., Z

an

dv

oo

rde

stra

at

30

0,

B-8

40

0 O

ost

en

de

Daikin products are distributed by:

VRV products are not within the scope of the

Eurovent certification programme.

The present publication is drawn up by way of information only and does not

constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has

compiled the content of this publication to the best of its knowledge. No express

or implied warranty is given for the completeness, accuracy, reliability or fitness

for particular purpose of its content and the products and services presented

therein. Specifications are subject to change without prior notice. Daikin Europe

N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest

sense, arising from or related to the use and/or interpretation of this publication.

All content is copyrighted by Daikin Europe N.V..