IS031B-02-2008 ENVIROGRAF® CI/SfB (68.5) 529F FIRE PROTECTION FOR AIR CONDITIONING UNITS MOUNTED IN CEILINGS Quick-fit installation Standard & acoustic versions Self-supporting covers Lightweight and flexible Extensive range of sizes Independently-tested Meets Doc B/E/L Regulations Meets IEE 16th Edition Regs Intumescent Systems Ltd, Envirograf House, Barfrestone, Dover, Kent, CT15 7JG, United Kingdom Phone: +44 (0) 1 304 842 555 – Fax: +44 (0) 1 304 842 666 – Email: [email protected] – URL: www.envirograf.com PROTECTING PROPERTY PROTECTING LIVES COPYRIGHT © 2008 INTUMESCENT SYSTEMS LTD AIR CONDITIONING – GET COVERED PRODUCT 31: AIR CONDITIONING PROTECTION COVERS DATA SHEET MEMBER OF THE FIRE PROTECTION ASSOCIATION For the very latest information, please visit our web site at www.envirograf.com
Transcript
Page 1: AIR CONDITIONING – GET COVERED · With rising temperatures, air conditioning units are becoming commonplace in many buildings. They do, however, provide a serious potential fire

IS031B-02-2008

ENVIROGRAF®

CI/SfB (68.5) 529F

FIRE PROTECTION FOR AIR CONDITIONINGUNITS MOUNTED IN CEILINGS

● Quick-fit installation● Standard & acoustic versions● Self-supporting covers● Lightweight and flexible

● Extensive range of sizes● Independently-tested● Meets Doc B/E/L Regulations● Meets IEE 16th Edition Regs

Intumescent Systems Ltd, Envirograf House, Barfrestone, Dover, Kent, CT15 7JG, United KingdomPhone: +44 (0) 1 304 842 555 – Fax: +44 (0) 1 304 842 666 – Email: [email protected] – URL: www.envirograf.com

PROTECTING PROPERTYPROTECTING LIVES

COPYRIGHT © 2008 INTUMESCENT SYSTEMS LTD

AIR CONDITIONING – GET COVEREDPRODUCT 31: AIR CONDITIONING PROTECTION COVERS DATA SHEET

MEMBER OFTHE FIRE

PROTECTIONASSOCIATION

For the very latest information, please visit our web site atwww.envirograf.com

Page 2: AIR CONDITIONING – GET COVERED · With rising temperatures, air conditioning units are becoming commonplace in many buildings. They do, however, provide a serious potential fire

Place the tent on itsback and thread thesupplied rodsthrough the centralretaining patch. Forlarger tents, threadthrough the centraland outer patches.

With the tent laid out, return it to its normalupright position and insert the rod ends intotheir pockets placed at each corner of thetent.

Place the tent over the aircon unit and feedthe cable through the ventilation hole,connecting it to the aircon unit according tothe manufacturer’s instructions. Go to eachcorner and pull the material away from thefitting over the T-bar and fix the material tothe T-bar with the supplied clips. Pinch eachclip with a pair of pliers to fix tightly.

Intumescent card is fixed to the top of thetent to provide entry points for support rodsor cables or pipes to pass through.Note: where the unit is already fitted, seamscan be made to allow the cover to be placedover the unit and the joints can be sealedwith the supplied adhesive.

VERY EASY TO FIT

TENTS ARE IDEAL PROTECTION FOR AIRCONDITIONING UNITS (SEE LEFT)

REGIONAL OFFICE

INSTALLATION OF INTUMESCENT FIRE TENT FOR USE OVER RECESSEDAIR CONDITIONING UNITS

COPYRIGHT © 2008 INTUMESCENT SYSTEMS LTD

With rising temperatures, air conditioning units arebecoming commonplace in many buildings. They do,however, provide a serious potential fire risk whenfitted into a suspended ceiling or fire-ratedplasterboard ceiling. Ducting outlets need to beprotected against fire and smoke as illustratedabove. In a fire, unprotected units could invalidateupper floor insurance claims, therefore it is crucial toprotect the air conditioning unit with a fireproofcover and to ensure you meet these regulations:–

ORDERING REFERENCESReference Length Width Height

AIR1 400mm 400mm 240mm

AIR2 400mm 400mm 280mm

AIR3 600mm 600mm 250mm

AIR4 850mm 850mm 240mm

AIR5 850mm 850mm 280mm

Includes adhesive and patches. All covers are rated one hour.

INTUMESCENT BLOCK GRILLE

DUCTCONNECTION

STEEL SLOTTED CHANNEL

STEEL WIRE ORBAR SUSPENSION

ENCLOSED STEEL OUTLETFOR AIR CONDITIONING

CEILING SPACE CEILING SPACE

ALUMINIUM DIFFUSER PLATESOR PROD 35: MG GRILLE PLATES

1 HOUR FIRE-RATED CEILING WITH STEEL PLENUM AND INTUMESCENT GRILLES

STEEL WIRE ORBAR SUSPENSION

CEILING CEILING

● Covers should be fitted to comply with revised16th Edition IEE Regulations of fire-ratedceilings

● Covers should be fitted to comply withDocument B of UK Building Regulations, tokeep the integrity of a suspended orplasterboard fire-rated ceilings

● Covers should be fitted to comply with newDocument E/L acoustic requirements

PRODUCT 35: MG GRILLE


Recommended