+ All Categories
Home > Documents > AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o...

AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o...

Date post: 27-Feb-2021
Category:
Upload: others
View: 7 times
Download: 0 times
Share this document with a friend
32
AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS Scot Waye, Matthew Musselman, Charlie King National Renewable Energy Laboratory 2014 Thermal Management Systems Symposium September 22–24, 2014 Denver, Colorado 14TMSS-0022 NREL/PR-5400-62920
Transcript
Page 1: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS Scot Waye, Matthew Musselman, Charlie King National Renewable Energy Laboratory 2014 Thermal Management Systems Symposium September 22–24, 2014 Denver, Colorado 14TMSS-0022

NREL/PR-5400-62920

Page 2: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Project Objective

2

• Enable air-cooling thermal management of automotive power electronics, with a focus on high-temperature devices

o Design, optimize, build, and demonstrate an air-cooled inverter

o Compare to conventional cooling systems: thermal resistance, coefficient-of-performance, volume, weight

Motivation

• Help industry achieve the DOE APEEM 2015 30-kW (55-kW peak) inverter targets (12 kW/L, 12 kW/kg) through improved thermal management

• Provide pathways to meeting 2020 targets (13.4 kW/L, 14.1 kW/kg)

Cost

Power Density, Specific Power, Efficiency

Page 3: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Project Perspective

3

All vehicles are air cooled

Air cooling a goal for batteries: • Simple • Direct

Just indirectly

Jim Snyder, NREL Image Gallery 15165

Page 4: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

State of the Art

4

LS 600H 2008

Camry 2007

Indirect Air Cooling via Liquid Cooling

Intermediate liquid cooling loop rejects heat to air

Direct Air Cooling

Has been done before

Honda Insight (12 kW)

AC Propulsion (150 kW)

Mitsubishi SiC Inverter (50 kVA/L, 400 V output, 156 kVA)

SiC = Silicon Carbide

Low Power

Low Power Density

Prototype: not in vehicle

NREL: John Rugh

Courtesy ORNL

DOE Advanced Vehicle Testing Activity (Idaho National Laboratory)

Page 5: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Air as a Coolant

5

• Air is a poor heat-transfer fluid (low specific heat, density, conductivity) • Large volume of air is needed • Large surface area increases heat transfer, but increases volume • Potential parasitic power of fan • Not yet used in production vehicles • Filtering, fouling, fan noise

Challenges

Advantages • Rejecting heat directly to air can eliminate intermediate liquid-air loops • Attractive for high-temperature device (wide-bandgap) applications • Air can be used to cool other components (e.g., capacitors) • Air is benign, is not carried, and does not need to be replaced • Air is a dielectric and can contact the chip directly • No global warming potential • No liquid leaks

Page 6: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

System-Level Analysis

6

Page 7: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

High-Temperature Air-Cooled Inverter

7

• Electrical Design: Device type and location; electrical duty cycles; temperature-dependent losses, efficiency

• Thermal Constraints: Maximum junction temperature; heat generation; coolant temperature

• Feasibility / Trade-Off: Modeling; extrapolate to inverter scale

• Thermal Design: Sub-module testing and model validation; fan/ducting testing; optimization

• Thermal System Design: Balance-of-system analysis; full system models

• Hardware: Module prototype, improve design; balance-of-system testing

Thermal Constraints

Thermal System Design

Thermal Design

Feasibility / Trade-Off

Hardware

Elec

tric

al D

esig

n (O

RNL)

Design

Prototype Development

Validation

Page 8: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Module Optimization to Inverter Level Characterization

8

1Casing volume adjusted for fin geometry 1Capacitor ~1.13 La, ~1.62 kga 1Gate driver + control board ~0.88 La, ~0.42 kgb

aAssumption provided by ORNL; bNREL assumption based on similar device measurement

Heat dissipation for 55-kW peak power From conservative analytical analysis ~ 2.7 kW heat (95% efficient)

• Fixed device heat generation and temperature (175ºC) • Parametrically optimized geometry by varying air flow

rate using computational fluid dynamics (CFD) – ANSYS Fluent

• Extrapolated sub-module modeling and testing results to module level

• Added in balance-of-inverter components1

Baseline

Optimized

Capacitor Capacitor

2 devices

9 modules 6 modules

Page 9: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Module Design Improvement (Parametric CFD)

9

Parametrically Changed: • Device Location • Fin Height • Fin Length • Base Plate Thickness • Fin Thickness • Channel Width

Improved weight and fan power

Improved volume and fan power

Modeling

Page 10: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Optimized Geometries Improve Specific Power

10

Baseline Optimized

Decreasing length

Increasing height

Changes to channel height and length

nine modules, DBC (direct-bond-copper)

Modeling

Page 11: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Balance of System: Ducting

11

Example Production Vehicle Air Ducts

Production Duct 1 Production Duct 2

Volkswagen Touareg Toyota Highlander Toyota Camry Toyota Prius Nissan Altima Hyundai Sonata Chevy Volt

Inverter Location

Surrogate ducting pressure curves

Experimental

Page 12: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Specific Power versus Parasitic Power for Various Heat Exchanger Geometries (Nine Modules)

12

Baseline

2015 Target

2020 Target

Power draw comparison AC blower AC condenser fan

Peak

Steady state

Low parasitic power but hard to meet targets

Modeling

nine modules, DBC (direct-bond-copper)

Page 13: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Specific Power versus Parasitic Power for Various Heat Exchanger Geometries (Six Modules)

13

2015 Target

2020 Target

Power draw comparison AC Blower AC Condenser fan

Peak

Steady-state

Meeting targets with acceptable parasitic power

Decreasing height

Increasing length

Modeling

six modules, DBC (direct-bond-copper)

Page 14: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Power Density versus Parasitic Power for Various Heat Exchanger Geometries (Six Modules)

14

2015 Target

2020 Target

Power draw comparison AC Blower AC Condenser fan

Peak

Steady-state

Meeting targets with acceptable parasitic power

Decreasing height

Increasing length

Modeling

nine modules, DBA (direct-bond-aluminum

Page 15: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

System-Level Test Bench

15

• Meets fan test standard o ANSI/AMCA 210-07 o ANSI/ASHRAE 51-07

• Range: 5–500 cfm • U95 Flow: ±1.5 cfm • U95 Pressure: ±1.6 Pa

Fan pressure curves Fan efficiency curves

Fan or duct test subject

Blower

Experimental

Page 16: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Example System Flow Study

16

Fan operation 45 – 70 W Heat

Pressure

2) Heat dissipation: 3.2 kW, exceeds 2.7 kW target

Example fan

3) Maximum flow rate: 115 cfm

1) Cross point of the fan curve and pressure loss

Page 17: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Sub-Module Heat Exchanger Experiments

17

devices

Heaters 2.7-kW heat dissipation

target for inverter

Baseline

Optimized

Prototypes provided by Sapa Extrusions USA (wire EDM)

Channel height – 15 mm Channel length – 74 mm

Channel height – 21 mm Channel length – 40 mm

ceramic heater Indium foil copper (with thermocouple) thermal epoxy

aluminum heat exchanger

Experimental

Page 18: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Heat Dissipation for Baseline Case (Nine Modules)

18

Specific Power*: 8.9 kW/kg Power Density*: 10.1 kW/L

*does not include inverter casing Extrapolated to inverter scale

Experimental

Page 19: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Heat Dissipation for Baseline Case (Nine Modules)

19

~ 60 cfm 5 W Fluid Power

Heat dissipation: 2.7 kW target

Tout ~ 100ºC

Specific Power*: 8.9 kW/kg Power Density*: 10.1 kW/L

Fan sized to satisfy flow rate and pressure drop

*does not include inverter casing Extrapolated to inverter scale

Experimental

Page 20: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL 20

Heat Dissipation for Optimized Case (Six Modules)

Specific Power*: 14.3 kW/kg Power Density*: 14.5 kW/L

*does not include inverter casing Extrapolated to inverter scale

Experimental

Page 21: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL 21

Heat Dissipation for Optimized Case (Six Modules)

Specific Power*: 14.3 kW/kg Power Density*: 14.5 kW/L

~235 cfm 180 W Fluid Power

Heat dissipation: 2.7 kW target

Specific power and power density meet 2020 targets, with tradeoff of higher parasitic power

*does not include inverter casing Extrapolated to inverter scale

Experimental

Page 22: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL 22

Heat Dissipation for Optimized Case (Six Modules)

Specific Power*: 14.3 kW/kg Power Density*: 14.5 kW/L

Heat dissipation: 2.7 kW target

Specific power and power density meet 2020 targets, with tradeoff of higher parasitic power

~135 cfm 40 W Fluid Power

*does not include inverter casing Extrapolated to inverter scale

Experimental

Page 23: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL 23

Heat Dissipation for Optimized Case (Six Modules)

Specific Power*: 14.3 kW/kg Power Density*: 14.5 kW/L

Heat dissipation: 2.7 kW target

Specific power and power density meet 2020 targets, with tradeoff of higher parasitic power

~50 cfm 4 W Fluid Power

Tout ~ 120ºC

*does not include inverter casing Extrapolated to inverter scale

Experimental

Page 24: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Inlet Temperature Effect (175ºC Junction Temperature)

24

Experimental

Page 25: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Fluid Power for Various Junction Temperatures

25

Experimental

Page 26: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Inlet versus Outlet Temperature at Various Junction Temperatures

26

Experimental

Page 27: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Module-Level Heat Exchanger Testing

ceramic resistance heaters

Experimental

27

Page 28: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Heat Dissipation of Module-Scale Heat Exchanger Experimental

Not extrapolated to inverter scale

28

Page 29: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Heat Dissipation of Module-Scale Heat Exchanger

Flat curves show low sensitivity to flow rate (reaching asymptote)

Experimental

Not extrapolated to inverter scale

29

Page 30: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Inlet and Outlet Temperatures of Module-Scale Heat Exchanger Experimental

Not extrapolated to inverter scale

Outlet temperatures reasonable

30

Page 31: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Summary

31

• Good potential technology for low cost, simple-to-manufacture options for high-temperature devices

• Eliminates liquid-to-air coolant loop • Provides potential solution to cooling components with lower

temperature limits (e.g., 85°C capacitor)

• Thermal performance for baseline and optimized sub-modules was characterized

• 10-kW module heat exchanger characterization and performance completed

• Parasitic power acceptable (in line with other vehicle components [e.g., A/C fan or condenser])

Page 32: AIR COOLING FOR HIGH TEMPERATURE POWER ELECTRONICS · 2015. 1. 7. · o ANSI/AMCA 210- 07 o ANSI/ASHRAE 51- 07 • Range: 5–500 cfm • U 95 Flow: ±1.5 cfm • U 95 Pressure: ±1.6

SAE INTERNATIONAL

Conclusions

32

• Reducing the number of modules (with penalty of increased heat generation from increased current and increased parasitic power) is beneficial for weight and volume considerations

• Further optimization to thermal and electrical solutions would further reduce weight and volume

• Balance of inverter component design and optimization vital to meeting targets

• More advanced heat exchanger designs may improve heat transfer efficiency with tradeoffs in manufacturability and cost

• Electrical and thermal aspects need co-design to meet targets


Recommended