+ All Categories
Home > Documents > AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate...

AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate...

Date post: 01-Jan-2016
Category:
Upload: gregory-shelton
View: 217 times
Download: 0 times
Share this document with a friend
23
AIR POLLUTION CONTROL AIR POLLUTION CONTROL FROM RICE SHELLERS- A FROM RICE SHELLERS- A CASE STUDY CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal , india [email protected] 919814695429
Transcript
Page 1: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

AIR POLLUTION CONTROL AIR POLLUTION CONTROL FROM RICE SHELLERS- A FROM RICE SHELLERS- A

CASE STUDYCASE STUDY

Presented by: Dr S.M Ahuja, Associate Professor,

SLIET,Longowal , [email protected]

919814695429

Page 2: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

RICE SHELLER LAYOUT

Page 3: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

POLLUTION FROM PADDY SILOPOLLUTION FROM PADDY SILO

AvseqRICE01_split001.mpegAvseqRICE01_split001.mpeg

SOURCES OF DUST EMISSIONS

Page 4: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

SUCTION FROM ALL THE DUST SUCTION FROM ALL THE DUST EMISSION POINTSEMISSION POINTS

NO. OF POINTSNO. OF POINTS

PADDY SILOPADDY SILO 22 ELEVATORSELEVATORS 11 FAN OVER SCREENS CONTAINED IN A WOODEN FAN OVER SCREENS CONTAINED IN A WOODEN

BOXBOX11

SCREENSSCREENS 22 HUSKERSHUSKERS 33 PADDY SEPARATORPADDY SEPARATOR 11 TOTAL 10TOTAL 10AvseqRICE02_split001.mpegAvseqRICE02_split001.mpeg

Page 5: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

CONTAINMENT OF DUSTCONTAINMENT OF DUST

COVERING OVER COVERING OVER HUSKERS (FRONT)HUSKERS (FRONT)

COVERING OVER COVERING OVER HUSKERS (BACK)HUSKERS (BACK)

Page 6: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

HOODS

Page 7: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

SUCTION FROM

DIFFERENT POINTS

Page 8: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

COVERINGS

Page 9: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.
Page 10: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

CONTAINMENT SYSTEMCONTAINMENT SYSTEM

COVERING BY INSTALLING SUITABLE COVERING BY INSTALLING SUITABLE HOODS / ENCLOSURES WHILE ENSURING HOODS / ENCLOSURES WHILE ENSURING WORKABILITY.WORKABILITY.

DUCTING USING PLASTIC PIPE SO THAT DUCTING USING PLASTIC PIPE SO THAT PRESSURE DROP IS MINIMAL.PRESSURE DROP IS MINIMAL.

EFFECTIVE SUCTION USING I.D. FAN. EFFECTIVE SUCTION USING I.D. FAN. ID FAN SPECIFICATIONID FAN SPECIFICATION

AIR FLOW RATEAIR FLOW RATE -- 4000 CUBIC METER 4000 CUBIC METER PER HOUR AT 25 degCPER HOUR AT 25 degC

PRESSURE DROPPRESSURE DROP -- 6 INCHES OF WATER6 INCHES OF WATER DUST CONCENTRATION 3600 mg/Nm3DUST CONCENTRATION 3600 mg/Nm3

Page 11: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

I

S

O

M

E

T

R

I

C

V

I

E

W

Page 12: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

SAILENT FEATURES

OF CYCLONE SEPARATOR

Page 13: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

AIR POLLUTION CONTROL AIR POLLUTION CONTROL DEVICEDEVICE

CRITICAL ANALYSIS OF DUSTCRITICAL ANALYSIS OF DUSTPARTICLE DENSITY- 1.8 grams/ccPARTICLE DENSITY- 1.8 grams/ccMEDIAN AERODYNAMIC DIAMETER- 14 micrometersMEDIAN AERODYNAMIC DIAMETER- 14 micrometers

BASED ON COMPUTER-AIDED DESIGN (CAD) OF CYCLONE SEPARATORBASED ON COMPUTER-AIDED DESIGN (CAD) OF CYCLONE SEPARATORLEITH-LICHT MODEL FOR ESTIMATING EFFICIENCYLEITH-LICHT MODEL FOR ESTIMATING EFFICIENCYIOZIA-LEITH MODEL FOR ESTIMATING PRESSURE DROPIOZIA-LEITH MODEL FOR ESTIMATING PRESSURE DROPKALEN-ZENZ MODEL FOR OPTIMIZATIONKALEN-ZENZ MODEL FOR OPTIMIZATION

UNIQUE DIMENSION RATIOSUNIQUE DIMENSION RATIOSESTIMATED DUST COLLECTION EFFICIENCY- 93%ESTIMATED DUST COLLECTION EFFICIENCY- 93%OVERALL DUST COLLECTION EFFICIENCY- 94%OVERALL DUST COLLECTION EFFICIENCY- 94%DUST LOAD- 250 Kg OF DUST DAILYDUST LOAD- 250 Kg OF DUST DAILY750 TONS DUST COLLECTED DAILY FROM RICE SHELLERS OF PUNJAB750 TONS DUST COLLECTED DAILY FROM RICE SHELLERS OF PUNJAB(ABOUT 50000 RICE SHELLERS IN INDIA)(ABOUT 50000 RICE SHELLERS IN INDIA)

Page 14: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

CYCLONE SEPARATORCYCLONE SEPARATOR

DUST.mpeg

Page 15: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

COMPARISON WITH OTHER COMPARISON WITH OTHER TECHNOLOGIESTECHNOLOGIES

COST EFFECTIVECOST EFFECTIVE NO ADDITIONAL MOTOR REQUIRED.NO ADDITIONAL MOTOR REQUIRED.

HP REQUIRED HP REQUIRED -- 3 TO 43 TO 4 HP REQUIREDHP REQUIRED -- 1515

SINGLE HIGH EFFICIENCY CYCLONE SINGLE HIGH EFFICIENCY CYCLONE INSTEAD OF TWO CYCLONE INSTEAD OF TWO CYCLONE SEPARATORS AND A BAG HOUSESEPARATORS AND A BAG HOUSE

Page 16: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

ECONOMIC GAINS DUE TO ECONOMIC GAINS DUE TO ADOPTION OF THIS ADOPTION OF THIS

TECHNOLOGYTECHNOLOGY IMPROVEMENT IN THE IMPROVEMENT IN THE

QUALITY OF BRAN.QUALITY OF BRAN. INCREASE IN THE LIFE OF INCREASE IN THE LIFE OF

RUBBER ROLLS.RUBBER ROLLS. INCREASE IN THE LIFE OF INCREASE IN THE LIFE OF

SHELLING MACHINERYSHELLING MACHINERY CUMULATIVE BENEFIT RS. CUMULATIVE BENEFIT RS.

100,000/- PER SEASON100,000/- PER SEASON PAY BACK PERIOD LESS PAY BACK PERIOD LESS

THAN A SHELLING SEASON.THAN A SHELLING SEASON.

Page 17: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

RICE SHELLER WITH APCD

ROTARY AIR LOCK

HOOD OVER PADDY SILO

Page 18: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

EMISSION STANDARDS FOR EMISSION STANDARDS FOR RICE SHELLERSRICE SHELLERS

EMISSION STANDARDS FOR SPM EMISSION STANDARDS FOR SPM (mg/Nm3)- 750*(mg/Nm3)- 750*

* * THE EXISTING UNITS NOT MEETING THE PRESCRIBED SITING GUIDELINES THE EXISTING UNITS NOT MEETING THE PRESCRIBED SITING GUIDELINES

WILL MEET A STACK STANDARD OF 500 mg/Nm3. WILL MEET A STACK STANDARD OF 500 mg/Nm3.

Page 19: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

IRREGULARITIES IN THE IRREGULARITIES IN THE INDUSTRYINDUSTRY

WRONG ROTARY WRONG ROTARY AIR LOCKAIR LOCK

IMPROPER IMPROPER CENTRAL TAPER CENTRAL TAPER MANIFOLD MANIFOLD

Page 20: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

CONTINUED:

CYCLONE SEPARATOR WITHOUT ANY HOPPER AND ROTARY AIR LOCK

Page 21: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

PRECAUTIONS/TROUBLE PRECAUTIONS/TROUBLE SHOOTINGSHOOTING

PROPER DRYING OF PADDY.PROPER DRYING OF PADDY. USE OF INSULATED HEATING TAPES USE OF INSULATED HEATING TAPES

IN CASE OF UNAVOIDABLE REASONS.IN CASE OF UNAVOIDABLE REASONS. MANOMETER FOR MEASURING MANOMETER FOR MEASURING

PRESSURE DROP.PRESSURE DROP. REPLACEMENT OF BAGS FITTED REPLACEMENT OF BAGS FITTED

BELOW THE ROTARY AIR LOCK.BELOW THE ROTARY AIR LOCK.

Page 22: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

REPLICATION OF THE REPLICATION OF THE TECHNOLOGYTECHNOLOGY

DEMONSTRATION POLLUTION CONTROL DEMONSTRATION POLLUTION CONTROL UNITS PARTIALLY FUNDED BY SMALL UNITS PARTIALLY FUNDED BY SMALL SCALE INDUSTRIAL DEVELOPMENT BANK SCALE INDUSTRIAL DEVELOPMENT BANK OF INDIA.OF INDIA.

TECHNOLOGY APPLIED -TECHNOLOGY APPLIED - 2000 UNITS2000 UNITS RETROFITTED 250 APCDs (CYCLONE RETROFITTED 250 APCDs (CYCLONE

SEPARATORS) BY PROVIDING COMPUTER SEPARATORS) BY PROVIDING COMPUTER AIDED CUSTOMISED DESIGNS FOR AIDED CUSTOMISED DESIGNS FOR INDIVIDUAL INDUSTRYINDIVIDUAL INDUSTRY

TECHNOLOGY HAS ALSO BEEN APPROVED TECHNOLOGY HAS ALSO BEEN APPROVED BY PUNJAB POLLUTION CONTROL BOARD BY PUNJAB POLLUTION CONTROL BOARD

Page 23: AIR POLLUTION CONTROL FROM RICE SHELLERS- A CASE STUDY Presented by: Dr S.M Ahuja, Associate Professor, SLIET,Longowal, india sandeepmahuja@gmail.com 919814695429.

THANKSTHANKS


Recommended