AIR QUALITY INDICATOR PROTOTYPE (AQIP) USING PETROLATUM
NATHANIEL DIMAOCOR and IRISH JANE ESPEJO
RATIONALE This study aims to contribute to the determination and
prevention of air pollution outdoors, as well as contribute a portable and cheaper way to determine the air quality of a certain location/area. This will also help us to have an idea in controlling pollution. This prototype can be also used in small-time industrial and commercial structures. This will also help other researchers by providing them idea that it is possible to develop an Air Quality Indicator Prototype by using petrolatum.
STATEMENT OF THE PROBLEM This research aims to design, fabricate,
and evaluate the performance of a portable Air Quality Indicator Prototype (AQIP).
It seeks to answer the following questions:
Is AQIP an effective determiner of air quality?
Is AQIP a reliable determiner of air quality?
METHODOLOGYCHAPTER III
A. RESEARCH DESIGN
The Randomized Complete Block Design (RCBD) will be the basis for the experimental design. The same amount of petrolatum will be impregnated on the heated laminating film and the prototype will be subjected to outdoor areas.
B. MATERIALS/EQUIPMENTMaterials:
7” x 5” (2” thick) block of wood Yellow paint
White paint
1” brush Wood saw 2 small hinges Chisel
Heated laminating film (without
paper) Apollo Petroleum Jelly
Equipment:
Laminating machine
C. GENERAL PROCEDURE
Gathering of Materials
The materials and equipment needed will be gathered.
C. GENERAL PROCEDUREConstructing the Wood Base
With the help of a carpenter, the wood base of the prototype will be constructed. The 152 x 216 x 10 MM block of wood will have a rectangular cut in the middle. This rectangular cut will be separated, but will have to remain undistorted. The rectangular cut would then be attached back with the use of the two small hinges. The sides of the rectangular cut will be carved so that plastic strips can have a grip at the sides. The wood surface will be painted with a primary coating (yellow paint), followed by the secondary coating (white paint). The paint will help achieve a smoother surface.
Figure 1. Air Quality Indicator Prototype (AQIP) Dimensions
C. GENERAL PROCEDUREPreparing the Petroleum Impregnated Plastic Strips
The two layers of laminating film (without paper in between) will be heated using the laminating machine. It will be cooled and then the petrolatum will be spread on the surface of one side of the plastic. To achieve an even spreading of the petrolatum on the heated laminating film, the heated laminating film (spread with petrolatum) will be covered with the thin plastic then will be rolled in the laminating machine. This way, excess petroleum jelly would be pressed outside and the resulting amount will be spread evenly on the plastic.
C. GENERAL PROCEDUREPreparation of Set-ups
In the preparation of set-ups, the plastic strips will be placed inside the wood base. The prototype will be hung outdoors to collect the fine particles. Every two days, the plastic strip will be removed and the results will be recorded.
D. DATA GATHERING During the experimentation, the amount of
fine particles will be determined every two days. After every two days, the plastic strip (with the fine particles collected) will be flashed with a beam of light, using a flashlight. The fine particles stuck in the set-up will absorb the light, then the intensity of the light shown will determine the air quality.
E. STATISTICAL TOOL
To verify that there is a significant difference among the results of the Air Quality Indicator Prototype (AQIP), the T-test will be used in our study.
BIBLIOGRAPHY
A. BLOG Haluzan, N. (November 4, 2010). What are the dangers of air pollution? Retrieved
from August 2011 website: http://pollutionarticles.blogspot.com/2010/11/what-are-main-dangers-of-air-pollution.html
Pearson, C. (January 13, 2010). Air Quality Test. Retrieved from August 2011 website: http://airqualitytest.org/
B. BOOK Cahill, T.A., Caroll, J.J., Campbell, D., Gill, T.E. (1996). Sierra Nevada Ecosystem Project:
Final report to Congress, vol. II. Davis, California: The Printer
C. INTERNET ARTICLES Annenberg Foundation (2011). Air Pollution Monitor. Retrieved August 2011 from website:
http://www.lbl.gov/Science-Articles/Archive/air-pollution-monitor.html
Air Now (September 3, 2010). Air Quality Index (AQI). A Guide to Air Quality and Your Health. Retrieved August 2011 from website: http://www.airnow.gov/index.cfm?action=aqibasics.aqi
DeWalt, T. (2009). E-How Health. What Are the Effects & Causes of Air Pollution? Retrieved August 2011 from website: http://www.ehow.com/facts_5489383_effects-causes-air-pollution.html
E-How Health (April 26, 2011). E-How Health. How to Check for Air Pollution Near a House. Retrieved August 2011 from website: http://www.ehow.com/how_2122175_check-air-pollution-near-house.html
Enercorp Instruments Ltd. (2008). Air Quality Monitors/Controllers. Retrieved August 2011 from website: http://www.enercorp.com/air/46.htm
C. INTERNET ARTICLES ESS Environmental Software and Services GmbH AUSTRIA (2000) AIR-EIA (Air Pollution and
Environmental Impact Assessment): The Mutlimedia Information Source. Retrieved August 2011 from website: http://www.ess.co.at/AIR-EIA/units.html
Francis, J. (2011). Air Quality Standards ISO 8573.1 & ISO12500. Retrieved August 2011 from website: http://www.airbestpractices.com/system-assessments/air-treatment/n2/air-quality-standards-iso-85731-iso12500
Friedlander, M. (January 24, 1996). Simple Device Allows Students to Measure Air Pollution. Retrieved August 2011 from website: http://www.lbl.gov/Science-Articles/Archive/air-pollution-monitor.html
Hardy, C. (March 9, 2009). Air Monitoring. New air quality device invented by scientists. Retrieved August 2011 from website: http://www.envirotech-online.com/news/air-monitoring/6/adfero/new-air-quality-device-invented-by-scientists/4343/
McFarlene, D. (July 30, 2007). Homemaking. 22 Wonderful Uses For Petroleum Jelly. Retrieved August 2011 from website: http://gomestic.com/homemaking/22-wonderful-uses-for-petroleum-jelly/
C. INTERNET ARTICLES Pine Environmental Services, Inc (n.d.). Indoor Air Quality. TSI P-Trak Ultrafine Particle Counter. Retrieved August
2011 from website: http://www.pine-environmental.com/indoor-air-quality/tsi-p-trak-upc.htm#content
Scholastic (n.d.). What’s in the Air? Retrieved August 2011 from website: http://www.scholastic.com/resources/article/whats-in-the-air/
Sevier, L. (February 23, 2010). Green Living. How to Check Air Quality in Your Area. Retrieved August 2011 from website: http://www.theecologist.org/green_green_living/how_to/420926/how_to_check_the_air_quality_in_your_area.html
Smith, S.T. (March 7, 2008). 7 Ways To Reduce Air Pollution. Become A Breath Of Fresh Air In Your Community. Retrieved August 2011 from website: http://www.lifescript.com/Life/Timeout/At-home/7_Ways_To_Reduce_Air_Pollution.aspx
Swansea Monitoring Team (2011). How do you measure air pollution. Retrieved August 2011 from website: http://www.swansea.airqualitydata.com/cgi-bin/faqs.cgi?3
U.S. Environmental Protection Agency (January 26, 2011). Fine Particle (PM2.5) Designations. Retrieved August 2011 from website: http://www.epa.gov/pmdesignations/
D. MAGAZINES Morrison, D.S. & Keller, E.A. (1996 January). Petrolatum: A Useful Classic. Cosmetics &
Toiletries. Vol. 111, 59-69.
E. WIKI Petroleum Jelly (n.d.). In Wikipedia. Retrieved August 2011 website:
http://en.wikipedia.org/wiki/Petrolatum
Particulates (n.d.). In Wikipedia. Retrieved August 2011 website: http://en.wikipedia.org/wiki/Particulates
End of presentation