+ All Categories
Home > Documents > Air Source Heat Pump - SOLFEX

Air Source Heat Pump - SOLFEX

Date post: 14-Jan-2022
Category:
Upload: others
View: 7 times
Download: 0 times
Share this document with a friend
76
Air Source Heat Pump Product Guide & Price List - 2015
Transcript
Page 1: Air Source Heat Pump - SOLFEX

Air Source Heat PumpProduct Guide & Price List - 2015

Page 2: Air Source Heat Pump - SOLFEX

Contents

4 - Contacts

5 - Why Heat Pumps?

6 - Planning Design and Support

7 - Training

8 - Heat Pump Training Dates 2015

10 - Prestige Heat Pump Packs

12 - Prestige Heat Pump Pack Components

14 - Other Accessories

16 - Unvented Cylinder

18 - Pre Plumbed Cylinder

20 - Buffer Tanks

22 - AEC

24 - Case Study

26 - Samsung EHS

28 - LG Electronics

32 - Hitachi

Page 3: Air Source Heat Pump - SOLFEX

For nearly a decade, installers have trusted SOLFEX energy systems to deliver their renewable energy products. Heat Pump systems and components are an integral part of this.

As part of the Travis Perkins PLC group of companies we offer our customers a solid, reliable distribution platform as well as heat pump expertise from a dedicated sales and

technical division.

SOLFEX energy systems can supply a range of renewable heat products and services for all applications, from domestic residential housing, utilising our renowned Prestige

Heat Pump Packages, through to a bespoke system for commercial applications such as hotels, sports & leisure facilities and manufacturing plants.

Our speciality is and always will be the integration of renewable and high efficiency products from the worlds leading manufacturers. As well as heat pumps, we also offer

market leading underfloor heating, solar thermal and solar photovoltaic products.

Our product management, technical and procurement teams operate alongside our manufacturing partners in order to provide a homogeneous approach to product

quality and service. Every component is carefully selected on its technical performance, longevity and warranty prior to being accepted within our portfolio.

Company Introduction

Page 4: Air Source Heat Pump - SOLFEX

4

Contacts

Head Office

SOLFEX LtdEnergy ArenaUnits 3-5Charnley Fold Industrial EstateBamber BridgePrestonLancashirePR5 6PS

Tel: 01772 312 847Fax: 01772 335 277Email: [email protected]

Expert Heat Pump support

Our Heat Pump sales team are always happy to help with any queries that you may have. Whether it be a sales order or a more technical question, our staff are highly trained in all aspects of heat pumps to ensure we give you the highest quality service.

Internal Sales & Technical Team External Sales Team

*On orders before 5pm

Order Online

www.webportal-solfex.co.uk

Chris HiggsProduct Manager

Tel: 00 44 1772 317013Email: [email protected]

Ben PerrisNational Sales Manager

Tel: 07792315189Email: [email protected]

Mary ColapintoSales Office Manager

Tel: 00 44 1772 317011Email: [email protected]

Rik WhinesTechnical Sales Engineer

Tel: 00 44 1772 317007Email: [email protected]

Sean McSorleyTechnical Sales ManagerLondon & Southern EnglandTel: 07807521766Email: [email protected]

Tom BainesTechnical Support Engineer

Tel: 00 44 1772 317003Email: [email protected]

Graham FurbyTechnical Sales ManagerEastern EnglandTel: 07792478420Email: [email protected]

24 hour shopping

You can now order all of our heat pump products online. Our webshop is quick and easy to use and allows you to order at a time and place that’s convenient. All orders before 5pm are eligible for next day delivery.

• Browseourfullproductportfolio,withfulldescriptions,datasheetsandpricing

• Open24/7• Nextdaydeliveryonordersbefore

5pm• Experttechnicaladvicejustaphone

callaway

NEW! Next Day

Delivery!*

Page 5: Air Source Heat Pump - SOLFEX

5

Why Heat Pumps?

Finally, you can control the cost of your own heatingHeat Pumps, most notably air source heat pumps, are fast becoming the most popular renewable heating source in the UK. To date, around 30,000+ MCS accredited air source heat pumps have been installed in the UK since 2009. Though heat pumps require electricity to run, the way that they utilize this electricity means that they are a very cost effective and environmentally friendly way to provide your hot water and space heating requirements all year round.Chances are, you already have a heat pump in your own home, in the form of a refrigerator. A common misconception is that a refrigerator makes things cold…. What it actually does is to take energy from inside the fridge and transports it to the back of the fridge, hence why if you touch the coil on the back of your fridge, it will be warm, whilst the inside of the fridge is cold.

If we reverse the operation, and apply it to an air source heat pump, you will find that the inside of the fridge now becomes your garden and the warmth on the back of the fridge is now the heat circulating around your pipework to your radiators / underfloor heating. The area directly in front of the heat pump will be much cooler than the rest of the garden because that energy is being transported into your property via the vapour compression cycle. Essentially, what is happening is that unusable energy from outdoors is being transformed into usable energy for indoors.

Air source heat pumps require electricity in order to power the compressor, circuit boards, circulation pumps etc.. For every 1kW of electricity used by the heat pump unit itself, it will provide around 4kW of heat. That means that 3kW of heat is being provided completely for free so you could say that a heat pump is around 400% efficient. If you compare this with a traditional gas boiler you will see that for every 1kW of energy used by the boiler, only around 90% of the fuel is used for heating. The rest is sent to the atmosphere via the flue. If you combine a heat pump with a SOLFEX PV system in order to offset some of the heat pump electricity usage, the running costs of the heat pump reduce even further and if you can also install a SOLFEX Solar Thermal and Underfloor Heating system you truly have a whole house solution.

As well as being one of the most efficient forms of space heating available, an air source heat pump installation may also attract a government subsidy in the form of the Renewable Heat Incentive. For a 4 bedroom semi-detached property this could equate to around £1000 a year in guaranteed index linked payments

*Based on an average 4 bed detached property

Heat Pump Savings

£0.00

Coal

Savings per year RHI Income per year

Gas

Electric

Oil

LPG

£700 £1,400 £2,100 £2,800

Page 6: Air Source Heat Pump - SOLFEX

6

PU 01

FA 01

PU 02

FA 02

FA 03

+

HE 01

+

HE 02

+

HE 03

-

CO 01

-

CO 02

-

CO 03

TT01

PT01

FT01

TI01

PI01

FI01

VA 01M

VA 03

VA 02M

VA 04

VA 05

VA 11M VA 12M VA 13VA 14

VA 15VA 16

VA 07

VA 08

VA 17VA 18

AV 01

air outlet

air inlet

air flow

AV 02

M

FC01

PC01

TC01

el.signal

EV 01

PU 0

2

VA 12M

GA 01

EV 02VA 12M

FI 01

PI01

CL 01

CD 01 SE 01 FI 01

CO 01

pn.signal

DR 01

HX 01

M

EX 01

MIssing components?

- make your own! -

publish the drawing and send us the link.

Components we believe add values to our users will be incorporated into our

templates.

Tips!

- Change the insertion points of components by selecting

"Format > Snap grid" and

"Format > Snap guidelines"

from the menu.

- Right click and "Ungroup" the objects to edit, m

ove, rotate text or change

details. Regroup after change.

- Copy components between drawings with the Web ClipboardSelect component(s) above! - c

opy and

paste into the drawing!

Project ID:

Drawing no:

Rev.

Classification:

Reviewer:

Date:Sheet: S-0002

of

Submitted:

Approved for release:

Drawn: CH

Design:

Date: 10/11/14Checked:

Training Room Mechanical Layout

Description

No DateClass Rev

DWNVER

CHKDSUB

APP

VA 06

FlexiVA

07

VA 06

VA

05

VA

05

VA

06VA 02M

VA 02M

VA

05

Auto

Bypass

Radiator

Bypass Loop

PU 01

PU 01

Buffer

Tank

DHW

Tank

To Hot Water

Services

Cold Mains In

MF 01

FS 01 FM 01

VA

06

VA

06

VA

07Flexi

VA

07

VA

07

Flexi

Flexi

VA

07

VA

07

Flexi

Flexi

VA

07

VA

07

Flexi

Flexi

CodePart

VA06Gate Valve

VA02Motorised 2 Port V

alve

VA05Non Return Valve

PU01Circulation Pump

EX01Expansion Vessel

MF01Magnetic Filter

FM01Flow Meter

FS01Flow Switch

VA07Isolation Valve

Planning Design and Support

AtSOLFEXenergysystemswecanspecify,design&indemnifyyourproposedheatpumpinstallation,fromastandardsmalldomesticinstallationtoacommercialheatpumpsystem.

When specifying a heat pump system for any building, key bespoke requirements of the building need to be taken into account such as:

• ProjectReference• SiteLocation• FloorArea• AgeofBuilding• NumberofBedrooms(Ifapplicable)• DomesticHotWaterRequirement(Ifapplicable)

The above are just some of the details we would require in order to approximately specify and dimension a heat pump system.

In order to specify the system accurately, SOLFEX energy systems can assist you with the completion of the BS EN 12831 heat loss calculation in line with the requirements for RHI and MCS. We have special tools and calculators built to assist with all aspects of the heat load calculation process.

Heat Pump Engineering Support• Pre-installation&on-siteinstallersupport/consultancybyour

trainedprofessionals• Samplehydraulicandelectricallayoutsformanysystems• Indemnityofthesystemdesignandspecification• Commissioning&on-siteinstallersupportthroughoutinstallation

canbeprovided.Enquireforfurtherdetails.

Customer Service & After-sales SupportAt SOLFEX energy systems customer support & service does not end when you have purchased & installed your system. Our dedicated internal technical support team will ensure your enquiry will be dealt with professionally and in a timely manner.

Dedicated On-Site SupportFurther to our dedicated internal team, we also have a team of external technical sales engineers who can provide on-site technical support to MCS accredited installers and consultants to ensure that projects are specified and installed as trouble free and as efficiently as possible.

Page 7: Air Source Heat Pump - SOLFEX

7

Training

SOLFEXenergysystemsprideourselvesonthesupportandcustomerserviceweoffer.Inordertoensurethatthespecificationandinstallationofyournewheatpumpisassmoothaspossible,weofferfulltrainingforourentirerangeofheatpumpsatvariouslocationsintheUK.

All training courses are divided into two very distinct parts and are always held over a single day so as to ensure that the impact on your business is kept to an absolute minimum. All training courses are delivered on live installations to make sure that your experience is as relevant as possible.

Part 1 – System Design and Unit Specification Heat Pump design and specification is very different to traditional fossil fuel heating sources. There are a number of different considerations which need to be taken into account prior to installation.

Part1oftheheatpumptrainingencompassessuchtopicsas:

• WhatisaHeatPumpandhowitfitstoaproperty• HeatPumpLocationandDrainageRequirements• OverviewofCirculationPumpSizing• HeatPumpOptimizedDomesticHotWaterCylinders• EmitterCircuitConsiderationsforRadiatorsandUnderfloorHeating• AlternativeSystemDesignincludingHybridSystems• ExplanationsofSPFandCOPefficiencies• AvailableIncentives• WhatisMCS?• CalculatingtheHeatLoadofapropertytorelevantstandards• ElectricalandMechanicalConsiderations

Part 2 – Installation and Commissioning The installation of a heat pump is very similar to that of a traditional fossil fuel boiler. The most evident difference is in the controls and commissioning of the system. If these are not treated with the utmost care, a very efficient system can quickly become inefficient.

Part2oftheheatpumptrainingencompassesthebelowtopics:

• LiveInstallationComponentOverview• FullCommissioningWalkthrough

After Sales Support SOLFEX energy systems understand that training does not begin and end in the classroom. With this in mind, we provide an unparalleled level of after sales technical support to ensure that all topics learned in the classroom can be successfully implemented in the field. As you leave the classroom you will be given two points of contact for dedicated technical support meaning that should you require assistance it will always be available.

Page 8: Air Source Heat Pump - SOLFEX

8

Heat Pump Training Dates 2015

Preston Chertsey Preston Slough Leeds Preston Maidenhead Preston

Jan 13th 16th 27th

Feb 24th 17th 5th & 24th 26th 10th 3rd

Mar 10th 5th & 24th 26th

Apr

28th 21st 14th 7th

May 12th 12th 26th

Jun 30th 23rd 16th 9th

Jul

14th 7th 28th

Aug

25th 18th 11th 4th

Sept 15th 8th 29th

Oct 27th 20th 13th 6th

Nov 10th 10th 24th

Dec 29th 22nd 15th 8th

Note - Dates are subject to change, please contact our Heat Pump sales team for confirmation of dates

Mary ColapintoSales Office Manager

Tel: 00 44 1772 317011Email: [email protected]

Booking

Formoreinformation,ortobookyourplaceatanyoftheHeatPumpTrainingCourses,contactMaryColapinto.

Page 9: Air Source Heat Pump - SOLFEX

9

Pres

tige

Hea

t Pu

mp

Pack

sPrestige Packs

Prestige ComponentsHeat Pump Accessories

Unvented CylindersPre Plumbed Cylinders

Buffer Tanks

Page 10: Air Source Heat Pump - SOLFEX

10

Prestige Heat Pump Packs

All SOLFEX energy systems air source heat pump prestige packs are designed with the installer in mind. In order to ensure that installations are as simple and as straightforward as possible, many packs have been hand crafted to allow for around 95% of the components you will require on site. As we only use the highest quality components, which are engineered to compliment the heat pump they are applied to, you can be sure that ordering a SOLFEX prestige pack guarantees you a peace of mind installation.To further add to your peace of mind, many packs are delivered on a single shipping pallet and packed so as to ensure that they are safe and protected in transit.

SOLFEX energy systems has long held a deserved reputation for promoting only the worlds leading manufacturers in relation to the main equipment we supply. This reputation however does not end at main products. We have, and always will, ensure that only the most suitable and highest quality components are used to compliment our range of Heat Pumps.

Page 11: Air Source Heat Pump - SOLFEX

11

When supplying around 95% of the equipment required by an installer on site, we have to be sure that the quality of the components will not negatively influence the installers perception of the main product, or indeed SOLFEX as a whole.

In order to ensure this confidence in our components is well placed, we only source our equipment from Europe. This ensures that we have full traceability back to manufacturer for anything as small as a single brass nipple through to something much larger like a buffer tank.Our involvement in components does not simply end at sourcing them. SOLFEX are also heavily involved in the design of many of our

components. In fact, much of the equipment you will find in our prestige air source heat pump packs can only be purchased through SOLFEX due to our continued and trusted relationship with our existing supply chain.

Page 12: Air Source Heat Pump - SOLFEX

12

Prestige Heat Pump Pack Components

Heat Pumps

Japanese, Korean and UK manufactured heat pumps from some of the biggest brands in the world. Each manufacturer possesses equipment which fulfils a specific requirement in the UK market.

Pre Insulated Flexible HosesWhen installing a monobloc heat pump, one of the biggest issues is ensuring that valuable energy is not lost from the pipework as it exits the heat pump and enters the building. This run may be no more than a metre, but it is extremely important that only the highest quality insulation and flexible hoses are used.

Anti Vibration Feet

When mounting a heat pump on the ground, it is very important to ensure that it is sufficiently anchored and stable. Providing a separation between property and heat pump is also extremely important to ensure that customers are not adversely affected by noise.

2 Port Valves2 port valves perform a very simple function; to deny or allow flow. The beauty of our Spanish made valves is in their design. A very simple but effective motorised opening system ensures that unlike many other 2 port valves, these are flexible enough for a wide variety of heat pumps without the worry of unwanted flow related error codes.

Control Kits

In order for any of the SOLFEX supplied heat pumps to work correctly, they require a very specific set of controls. Each control kit is designed to be as straightforward to set up and commission as possible

Isolation ValvesThe means of hydraulically isolating the outdoor heat pump unit from the rest of the heating system is a task which should only be left to the highest quality isolation valves. SOLFEX full bore lever arm isolation valves ensure the absolute minimum resistance when open, and a secure leak free confidence when closed.

Page 13: Air Source Heat Pump - SOLFEX

13

Flow Meter

No heat pump can be accurately commissioned without the use of a specific flow meter. SOLFEX flow meters not only provide an accurate way to measure the flow through the system, but they also provide a means of correctly filling the system through the integrated ¾” flush and fill ports.

Tyfocor

Propylene glycol is very important in order to guarantee the continued operation and lifespan of your air source heat pump. For the manufacturers which require glycol to be added to the system as part of their warranty conditions, SOLFEX provide only the most trusted food safe propylene glycol.

4 pole isolator switch

To protect yourself and your customers, it pays to ensure that electrical isolation is handled by a world leader in electrical switchgear. Our German manufactured isolator switches by Kraus and Naimer are among the best in the world.

Brassware

In order to ensure that small components are not the cause of negative perceptions towards the heat pump packs or SOLFEX in general, only the best Italian manufactured brassware is included in our packs. All brassware is manufactured to ensure the best possible seal.

Installation specific literature Together with around 95% of the components you require on site, we also provide comprehensive installation and commissioning instructions for a wide variety of installation types. Whilst generally, installations will be very similar, having a dedicated manual which outlines the specific wiring and controller setup can make a huge difference to an installer in terms of cost and time. All literature is backed up by our internal technical support team should you have any questions.

Magnetic Filter

Nothing will damage a heat pump’s plate heat exchanger quicker than metallic sludge present in the heating system. All systems should be power flushed prior to connection, but it only takes a few microns of metallic sludge to render a heat exchanger inefficient. SOLFEX magnetic filters are proven in the field to ensure that heat exchangers remain efficient and problem free.

Buffer Tanks

Many heat pump manufacturers now insist on the use of buffer tanks in order to ensure that the correct volume of water is available to the heat pump at all times. Where applicable, our prestige packs provide buffer tanks which are sized specifically in line with the manufacturers instructions.

take pic

Page 14: Air Source Heat Pump - SOLFEX

14

Other Accessories

OWL is the UK’s premium brand of wireless energy monitoring and control products. The OWL team combines many years of commercial experience with an in depth knowledge of wireless hardware and cloud software development. Since their inception in 2006 they have designed and manufactured a broad range of high quality products which have become household favourites.

Specifically designed to remotely control heating systems which incorporate a Heat Pump. OWL Intuition HPW remotely controls the heating system from any internet connected device from anywhere and anytime. How does it work? Network OWL Gateway simply plugs into the home’s broadband router. This provides a secure connection to the OWL Intelligent Cloud software platform. The Network OWL Gateway automatically sends energy consumption and generation data to the cloud from the OWL Sensors and Transmitter. This can then be viewed via a clear, easy-to-use web dashboard showing live and historic data from any Internet connected computer or device and from anywhere.

Bronz-Glow are a market leading company that specialise in the field of corrosion protection for heat exchangers. This covers a large field of applications and throughout 25 years of experience, they have been able to develop new techniques that make Bronz-Glow unique.

Available Processes

• FullHeatPumpcolourchangetoanyRALcolour• Anti-corrosionprotectionforhighpollutionormarineenvironments

Features & Benefits

• Remotelycontrolyourheatingsystem• Accessheatpumpcontrolviaanyinternetconnected

device• Viewtheamountofelectricityconsumedbyyour

HeatPump• ComparetheHeatPumpenergyconsumptionwith

overallenergyconsumptioninyourproperty.

Page 15: Air Source Heat Pump - SOLFEX

15

Flexible Hoses

When connecting from the heat pump to the property services it is always advised that a set of stainless steel EPDM lined flexible hoses are used prior to connection to rigid pipework. Our flexible hoses are manufactured in the UK specifically with air source heat pumps in mind. The bend radius of the hose is more than adequate to accommodate the installation dimensions associated with a heat pump.

Pipe Insulation

Poor insulation can considerably increase the running costs of an air source heat pump system. In order to limit these parasitic heat losses it is vitally important that high quality insulation from a trusted brand is used. SOLFEX exclusively supply HT ARMAFLEX Foamed EPDM rubber insulation in many pipe sizes and thicknesses.

Low Loss Headers

In order to ensure that there are no flow issues between the heat pumps hydraulic requirements and the emitter circuit, in many cases it is advisable to employ a low loss header. One such instance is when utilizing a heat pump on an underfloor heating circuit which requires a difference in flow and return temperatures of 10 degrees, whilst the heat pump circuit will require a 5 degree temperature difference.

Hand Held RefractometerWhen commissioning many air source heat pump systems, it will be vitally important to ensure that the concentration of glycol in the system is at the level required to provide the expected protection down to a specific ambient temperature. The only accurate way to measure glycol concentration is through the use of a refractometer. SOLFEX provide only the highest quality refractometers to ensure an accurate reading.

Through Wall Kit

Running pipework from an externally mounted air source heat pump into a property requires the pipework to run through the exterior wall. The hot pipework will be affected by cold bridging and heat loss if it is not insulated correctly. The Through Wall Kit provides both thermal insulation within the wall complete with elbow section to cover the copper connection.

Wall Mounting Brackets

These flat-packed, self assembly brackets provide a professional finish to the installation of wall mounted outdoor condensing units and air source heat pumps. The Type 2 brackets have a crossbar allowing the uprights to be spaced exactly as required, and include wall spacers to help level the unit on uneven walls.

3 Port Diverter Valve

Our Spanish manufactured 3 port diverter valves are specifically manufactured for use with heat pumps. Being a true diverter valve and not a mid position valve, there is no danger of supplying heating in the middle of summer when the hot water cylinder is being satisfied.

Filling Station

When commissioning a system, it is imperative that a high quality filling and flushing station is used (in conjunction with an appropriate sanitizer solution) in order to ensure that pipework is bacteria and contaminant free prior to final filling. Once bacteria free, a high pressure fill is required to ensure that air does not remain in the system. The Solarcheck Mobilcenter from SOLFEX is perfect for this task.

Page 16: Air Source Heat Pump - SOLFEX

16

Unvented Cylinders

Solfexareproudtoofferacompleterangeofunventedstainlesssteelcylindersspecificallyforheatpumpapplicationsprovidingmainspressuredomestichotwater.

Utilising an already well established stainless steel unvented hot water cylinder, this product has been developed to maximise the lower temperatures available from the heat pump.

The heat exchanger is a totally new design. It consists of a multi-pass corrugated stainless steel tube in parallel to reduce the pressure loss whilst maximising the heat exchange. Many medium to large heat pumps need heat exchangers in the store that will cope with the higher flow rates associated with primary temperatures that are typically 50˚C or 60˚C.

Due to the fact that many heat pumps will not raise the stored water temperature to 60˚C, which is necessary to prevent the growth of legionella, the SOLHP range of cylinders are supplied with an immersion heater and a thermostat.

Duplex Stainless SteelThe latest high specification Duplex stainless steel resists all forms of corrosion including crevice and stress whilst its high mechanical strength gives it durability. The very latest automated welding procedures along with full post weld treatments guarantee welds that are as strong as the metal. All cylinders are factory pressure tested to a full 12 bar which is four times the normal working pressure.

Quality StandardAll SOLHP cylinders are manufactured in accordance with BS EN 12897 the specification for unvented water storage vessels. The cylinders have been tested by NSF-WRc and WRAS, and found to comply with Building Regulations G3 and Water Regulations.

In performance, it complies with the requirements of BS EN 806-1 to 5 and meets the NHBC criteria for domestic properties. Our manufacturing partner also operates a quality management system audited and accepted by the BSI in accordance with BS EN ISO 9001:2008.

Special features

• ThelatestandhighestqualityDuplexStainlessSteel

• 25yearguarantee.

• Fastreheatratefromitspurposedesignedlowresistancecoil.

• Oneofthehighestinsulationratingsonoffertoday.

• TheStainlessLiteHPSOLissuppliedwithallthenecessaryconnectionsincludingtwodrythermostatpockets.

Corrugated Stainless Steel CoilSOLHP cylinders use a high heat transfer corrugated tube heat exchanger to give a 20% faster recovery than plain tube. It is also lighter and stronger than plain tube making the vessel the lightest and easiest to handle on site.

Heat LossAll SOLHP cylinders are manufactured using the very latest HCFC free EnviroFoam insulation. This has an Ozone Depletion Potential (ODP) of zero and an industry leading Global Warming Potential (GWP) of 0.7. Tests show that the 50mm of EnviroFoam insulation injected into the case and covering both domes achieves astonishingly low levels of heat loss, which ensures it is fully compliant with 2010 Part L requirements for both new build and replacement cylinders.

25 Years GuaranteeThe 25 year guarantee underlines the confidence the manufacturer has in its own products.

Page 17: Air Source Heat Pump - SOLFEX

17

SOLHP180 SOLHP210 SOLHP250 SOLHP300 SOLHP400SOLHP180

SLIMSOLHP210

SLIM

Capacity - Total Volume Litres 180 210 250 300 400 180 210

Dedicated Solar Volume Litres 65 75 90 105 130 - -

Standing Heat Loss Rate kWh/24h 1.48 1.7 1.85 2.04 2.82 2.01 2.23

Weight (empty) Kg 33 38 43 49 61 33 37

Weight (full) Kg 213 248 293 349 461 213 247

Pressure Regulating Valve Setting

Bar 3 3 3 3 3 3 3

Expansion Relief Valve Setting

Bar 4.75 4.75 4.75 4.75 4.75 4.75 4.75

Temperature Setting (P&T valve)

°C 95 95 95 95 95 95 95

Pressure Setting (P&T valve) Bar 6 6 6 6 6 6 6

Expansion Vessel Size (Volume)

Litres 18 24 24 35 2 x 24 18 24

Expansion Vessel initial charge pressure

Bar 3 3 3 3 3 3 3

Height mm 1305 1495 1745 1992 2030 1790 1970

Diameter mm 550 550 550 550 630 475 475

Surface Area of Solar Heater Coil

m² 0.68 0.68 0.97 0.97 1.27 - -

Solar Coil Pressure Loss�* Bar 0.191 0.191 0.241 0.241 0.31 - -

Heat Pump Coil Surface Area

m² 1.36 1.56 1.94 2.04 2.91 3.01 3.01

Heat Pump Coil Thermal Rating*

kW 24.3 26.2 27.5 34.2 47.2 32.8 31.2

Heat Pump Coil Pressure Loss*

Bar 0.048 0.054 0.06 0.019 0.027 0.018 0.018

ModelSelectionGuide

NumberofBedroomsinproperty Model

1 SOLHP180

2 SOLHP210

3 SOLHP250

4 SOLHP300

5 SOLHP400

6 SOLHP400

All cylinders are supplied with:

• Combinationinletgroupincorporatingpressurereducingvalve,strainer,checkvalve,balancecoldtakeoffpoint,expansionreliefvalveandexpansionvesselconnectionpoints.

• Potableexpansionvesselsc/wflexiblehoseandwallbracket

• Tundish

• Dualcontrolthermostatandcombinedoverheatthermostat(x2)

• Twoport(28mm)zonevalveforprimarycircuit

• Wiringjunctionboxforprimarysystem

* Measured at 15lpm primary flow rate Notes 1. All connections are supplied with compression fittings for direct connection to copper pipework

2. When selecting a model to be used with solar thermal, it is important to look at over sizing the vessel by 30% to account for reduced input from the solar thermal between around March and October

Page 18: Air Source Heat Pump - SOLFEX

18

Pre Plumbed Cylinders

Special features

• ManufacturedintheUK

• ExceptionallyLowStandingHeatLosses

• IndustryStandard3m²HeatingCoil

• SmartAttractiveWhiteCasedUnit

• 25YearWarrantyonVessel

• Slimline(550mmdiameter)optionavailable

• Highestqualitycomponentsused

• Around80%ofcomponentsrequiredonsitepreplumbed

The Solfex Pre Plumbed Cylinder Provides all of your domestic hot water needs in a single extremely efficient packaged solution.

To create the simplest possible heat pump installation, SOLFEX energy systems, in conjunction with their UK manufacturing partner have created the SOLFEX Pre Plumbed Cylinder.

Available in a range of sizes from 180ltr through to 300ltr and diameters from 575 mm to 650 mm, the pre-plumbed cylinder is one of, if not the most versatile heat pump specific cylinder on the market. All models come complete with around 80% of the components you would require in a sealed heating and hot water system already pre plumbed to the cylinder, effectively saving around half a day’s labour for a plumbing and heating engineer.

Page 19: Air Source Heat Pump - SOLFEX

19

PrePlumbedCylinderTechnicalSpecificationHP-PP-180SLIM HP-PP-210SLIM HP-PP-250 HP-PP-300

Height mm 1790 1970 1745 1992

Approx Diameter mm 575 575 650 650

Weight (empty) kg 46.3 50.3 56.3 71.3

Weight (full) kg 226.3 260.3 306.3 371.3

Capacity Litres 180 210 250 300

Standing losses kWhr/24hr 2.01 2.23 1.85 2.04

Surface area of Heat Pump coil m² 3 3 3 3

Cylinder Warranty 25 Years 25 Years 25 Years 25 Years

Cylinder Components & Electronics Warranty 2 years 2 years 2 years 2 years

Connections

1. Hotwaterdrawoff

2. Coldmainsin

3. Secondaryreturn*

4. Hotwaterflow

5. Centralheatingflow

6. HeatPumpreturn

7. DHWthermistorlocation

8. HeatPumpFlow

9. HotWaterReturn

10. CentralHeatingReturn

* Not present on 180ltr cylinders

Component Kit supplied seperately

• Potableexpansionvessel(s)c/wflexiblehose&wallbracket

• 2Port(22mm)Zonevalveforprimarycircuitenergycutout

• Wiringjunctionboxforprimarysystem

A. Temperature&Pressurereliefvalve

B. Autoairvent

C. 3Portdivertervalve

D. ControlsMountingPlate

E. Flowmeterwithflush&fillports

F. Tundish

G. FillingLoop

H. MagneticFilter

I. OverheatThermostat

J. CirculationPump

K. CylinderDrainoff

L. AutoBypass

M. ImmersionHeater

N. SystemDrainoff

Pre Plumbed Components

2

3

7

G

D

F

I

K

M

A

B

C

E

H

J

L

N

4

1

5

6

10

9

8

ModelSelectionGuide

NumberofBedroomsinproperty Model

1 HP-PP-180SLIM

2 HP-PP-210SLIM

3 HP-PP-250

4 HP-PP-300

Notes

1. All connections are supplied with compression fittings for direct connection to copper pipework

Page 20: Air Source Heat Pump - SOLFEX

20

Buffer Tanks

Special features

• ManufacturedintheUK

• ExceptionallyLowStandingHeatLosses

• 9Connectionsonvesselasstandard

• SmartAttractiveWhiteCasedUnit

• 25YearWarrantyonVessel

• InspectionHatchformaintenance

SOLFEX energy systems multi connection Buffer Tanks assist in remedying many heat pump installation issues.

To increase the lifespan of key heat pump components, as well as to ensure that potential flow related issues are not applicable, SOLFEX Energy Systems in partnership with their UK based manufacturing partner are proud to offer a flexible solution to a multitude of installation types.

Many heat pump manufacturers have a specific requirement for minimum water volume in order to increase the lifespan of the units compressor. In some cases, this can be far above what would normally be present in a heating system. In this instance, a SOLFEX buffer tank can provide the much needed dedicated system volume.

As the name buffer suggests, these tanks are also extremely capable of storing energy for multiple uses. This energy may be required when the heat pump goes into defrost mode or even when it is serving domestic hot water. Every minute that a heat pump is serving domestic hot water is a minute that the heat pump is not providing central heating. A buffer tank can assist in tackling this problem.

BufferTankTechnicalSpecification

SOLMB090 SOLMB120 SOLMB210 SOLMB250 SOLMB300 SOLMB400

Capacity - Total Volume litres 90 120 210 250 300 400

Height mm 745 930 1495 1745 1992 2030

Diameter mm 550 550 550 550 550 630

Weight (empty) kg 13 18 28 32 37 51

Weight (full) kg 103 138 238 282 337 451

Standing Losses kWh/24h 0.85 1.06 1.7 1.85 2.04 2.82

Max Working Pressure bar 3.5 3.5 3.5 3.5 3.5 3.5

Connections mm 28mm x 8 35mm x 8

Thermostatic Pockets 2 (1 x top & 1 x bottom)

Page 21: Air Source Heat Pump - SOLFEX

21

Hea

t Pum

psAEC

SamsungLG

Hitachi

Page 22: Air Source Heat Pump - SOLFEX

22

AEC

Special features• UKDesigned,Manufactured&

Distributed

• Highestqualityconstructionwithcorrosionprotectedevaporatorcoil

• RemoteAccessasstandardmeaningnomoreblindattendancestosite.Youseewhattheheatpumpsees

• Threedifferentcolourwaystoensuretheheatpumpmatchestheproperty.100’smoreonrequest

• 7yearwarrantyfullpartsandlabourwarrantyasstandard

• Allcomponentswirebacktointernalauxiliaryboxtoensurethatinternaltoexternalcablingiskepttoanabsoluteminimum

• Prefertheexpansionvesselandcirculationpumptobelocatedoutside?Choosetheenhancedheatpumprangeforthequickestinstallation

• Preferthechoiceofwhereexpansionvesselandcirculationpumparelocated?Choosethestandardunitforfullflexibility

For many years, the UK has been at the forefront of manufacturing. However, up until now, there has been very little UK design and build representation for air source heat pumps. In 2015, Solfex Energy Systems released the AEC range of air source heat pumps. AEC or Ambient Energy Collector, does exactly what it suggests. The real beauty of this product is that it has been built from the ground up to be as simple and as easy to install as possible. Everything from remote access to all aspects of the heat pump, to on board installation of the circulation pump and expansion vessel, make the AEC range of equipment the new benchmark for air source heat pump design in the UK.

UK Manufactured

Page 23: Air Source Heat Pump - SOLFEX

23

5 9Standard 9Enhanced

Power Supply

Phase = Single Single Single

V = 220-240v 220-240v 220-240v

Hz = 50Hz 50Hz 50Hz

Nominal ConditionAir 7ºC Flow 30/35ºC

Heating Output: kW 5.5 9 9

Electrical Input: kW 1.22 2.55 2.55

COP: 4.52 3.45 3.45

Performance Air 7ºC Flow 40/45ºC

Heating Output: kW 5 9 9

Electrical Input: kW 1.56 2.75 2.75

COP: 3.21 3.24 3.24

Performance Air -7ºC Flow 30/35ºC

Heating Output: kW 4.5 8 8

Electrical Input: kW 1.32 3.11 3.11

COP: 3.4 2.57 2.57

Performance Air -7ºC Flow 40/45ºC

Heating Output: kW 4.5 8 8

Electrical Input: kW 2.01 3.81 3.81

COP: 2.24 2.1 2.1

Water Side

Heat Exchanger Type: Alfa Laval Plate heat exchanger

Max Permissible Water Press. bar 3 bar 3 bar 3 bar

Nominal Water Flow Rate: L/min 15.72 25.12 25.12

Minimum Water Volume: l 20ltrs 20ltrs 20ltrs

Pressure Drop at Heat Ex: kPa0.23 Bar @ 27.2

(L/min)0.19 Bar @ 35 (L/

min)0.19 Bar @ 35 (L/

min)

Pipe Connection: inch 1" BSP male thread 1" BSP male thread 1" BSP male thread

Fan Info

Quantity: - 1

Airflow Rate: m³/min 72.6m3/min (Max)

Output Power: W 0.105 (kW)

Refrigerant Side

Compressor Type: - Hermetic twin rotary

Oil: POE

Compressor Power: kW 1.1 (kW) 2.9 (kW) 2.9 (kW)

Refrigerant Type: - R410A

Refrigerant Factory Charge: g 1.7kg 2.4kg 2.4kg

Electrical Info

Running Current: MAX, A 13A 23A 23A

Starting Current: A 3A 5A 5A

Recommended Fuse Size: A 16A 25A 25A

Sound InfoSound Pressure Level dBA 45dBA @ 1 metre 48dBA @ 1 metre 48dBA @ 1 metre

Sound Power Level dBA 54dBA 57dBA 57dBA

Dimensions: HWDH,706mm D,395mm W,980mm

H,1012mm D,395mm,W

1032mm

H,1012mm D,395mm

W,1300mm

Weight: kg 65kg 85kg 100kg

Operating RangeAmbient (A2W): °C -15°C to +35°C

Leaving Water: °C 55°C max 55°C max 55°C max

AEC Technical Data

Page 24: Air Source Heat Pump - SOLFEX

24

Case Studies

InstallationCompany: ESTRenewablesLimited

Property Type: 4 bedroom detached Retrofit

Location: Hutton, Preston Suburbs

Heat Pump: AEC 9e

Design Temp: -2.2°C

Insulation Levels: High (High Specification Cavity Wall Fill and Loft Insulation)

Heat Load: 12kW (8kW Covered by Heat Pump)

Hybrid Heating Fuel: Oil Boiler

Solar Thermal Installed: 4 x FK250

Heat Emitter: Underfloor Heating

The detached property in Hutton, Lancashire had already benefited from the installation of Solar Thermal a couple of years previous and with continually increasing oil costs, Mr Givens decided it was time to look at alternative central heating sources. Because Mr Givens wasn’t 100% sure about completely removing his oil central heating boiler and replacing it with an air source heat pump system, the decision was made instead to utilize an AEC heat pump in conjunction with the existing oil boiler. The most cost effective way to treat this installation was to use the existing boiler to serve the domestic hot water, whilst the heat pump would serve around 80% of the heating requirements for the property. The intention is that the boiler will only ever be used for central heating when the temperature drops below around 0°C. This ensures that the lions share of the heating can be delivered from the heat pump. The high specification radiators installed were already adequately sized for the lower flow temperature available from the heat pump.

Page 25: Air Source Heat Pump - SOLFEX

25

Case Studies

InstallationCompany: SmartohmsLimited

Property Type: 4 bedroom detached new build

Location: Ribbleton, Preston Suburbs

Heat Pump: Samsung RC090MHXEA

Design Temp: -2.2°C

Insulation Levels: Very High (Virtually Passive House)

Heat Load: 5.5kW

Previous Heating Fuel: No previous fuel. Mains Gas available

Heat Emitter: Underfloor Heating

Solar Photovoltaic Installed: 10x Kioto 225wp Black Monocrystalline Modules

Solar Thermal Installed: 2x IFK 2.1 Solar Thermal Collectors

In order to best capitalize on the opportunity available when building a brand new property, Smartohms Limited, both client and installer, decided that the knowledge and experience available from SOLFEX together with industry leading Photovoltaic Panels, Solar Thermal Panels and Air Source Heat Pump would produce the best possible integration of a multitude of technologies. With aesthetics and panel performance being extremely important, Ten Kioto 225wp Mono PV Panels with black frames and black back sheets were selected which are complemented with two IFK 2.1 in roof solar thermal collectors coupled to a twin coil heat pump and solar thermal domestic hot water cylinder.

The centrepiece of the heating system is the Samsung 9kW RC090MHXEA Air Source Heat Pump, which, coupled to a wood burning stove, via a buffer tank with integrated coil can provide all of the heating and hot water requirement for the property at even the coldest times of the year. In order to ensure that the running costs are as low as possible, the heat pump has been integrated with underfloor heating upstairs and downstairs to create a very efficient heating system.

Page 26: Air Source Heat Pump - SOLFEX

26

Samsung EHS

Special features• Extremelyquietoperation(50db(A)

at1metre)

• InternalMIMControlKitsignificantlyreduceselectricalworksrequired

• Comprehensiveinstallationspecificliteratureprovided(Hybrid,Standaloneetc.)

• Marketleadingcalculationsoftware(builttoBSEN12831)available

• Lightweightconstructionensuringmanymountingoptions

• Flexibleinstallationethoswithabilitytoincorporatemanydifferentfuelsources

• 7yearwarrantyavailableasanadditionaloption

Samsung, as the 8th most valuable brand in the world, have a deserved reputation for innovation and quality.

While they were a relatively late comer to the air source heat pump market in 2011, what they brought with them was a solution to many of the problems that earlier manufacturers had encountered. Innovations such as commissioning information designed around a specific type of installation and an extremely lightweight chassis meant that installation and commissioning was some of the easiest ever seen from a heat pump.

The training and technical support available for the equipment is second to none and when coupled with the extremely competitive price point, ensures that the Samsung equipment is quick becoming the go to product for large scale installations.

Page 27: Air Source Heat Pump - SOLFEX

27

RC090 RC160

Power Supply

Phase = 1 1

V = 220-240V 220-240V

Hz = 50 50

Nominal ConditionAir 7ºC Flow 30/35ºC

Heating Output: kW 9 16

Electrical Input: kW 2.09 3.81

COP: 4.3 4.2

Performance Air 7ºC Flow 40/45ºC

Heating Output: kW 8.4 15.1

Electrical Input: kW 2.51 4.58

COP: 7.54 12.28

Performance Air -7ºC Flow 30/35ºC

Heating Output: kW 3.35 5.64

Electrical Input: kW 2.25 2.18

COP: 7.59 12.01

Performance Air -7ºC Flow 40/45ºC

Heating Output: kW 3.86 6.08

Electrical Input: kW 1.97 1.98

COP: 1.97 1.98

Water Side

Heat Exchanger Type: Brazed Plate Heat Exchanger

Required Water Press. bar 2.8 2.8

Nominal Water Flow Rate: l/min 20 30

Minimum Water Volume: l 20 20

Pressure Drop at Heat Ex: kPa 10 15

Pipe Connection: inch 1" male 1" male

Fan Info

Quantity: - One Two

Airflow Rate: m3/min 50 100

Output Power: W 8.4 14.9

Refrigerant Side

Compressor Type: - Rotary Inverter Rotary Inverter

Oil: POE POE

Compressor Power: kW 2.51 4.6

Refrigerant Type: - R410A R410A

Refrigerant Factory Charge: g 1.4 2.2

Electrical Info

Running Current: MAX, A 17.4 30A

Starting Current: A 2 2A

Recommended Fuse Size: A 20A 32A

Sound InfoSound Pressure Level dBA 50 53

Sound Power Level dBA 66 70

Dimensions: HWD 998x940x330 1,420x940x330

Weight: kg 75 103

Operating RangeAmbient (A2W): °C -20°C to 35°C -20°C to 35°C

Leaving Water: °C 25 to 55°C 25°C to 55°C

Samsung EHS Technical Data

Page 28: Air Source Heat Pump - SOLFEX

28

LG Electronics

The LG Therma V is designed for energy efficiency, comfort & ease of installation. LG’s inverter technology ensures the highest seasonal energy efficiency in combination with optimally designed components such as the water pump, heat exchanger and fan motor.

Moreover, the pressure control technology provides stable heating capacity at low temperature and reaches target performance without difficulties, ensuring you get heating when it’s required most.

Ease and speed of installation is obtained through factory fitted components such as A-class circulation pump, plate heat exchanger, expansion vessel & electric back-up heater. Additionally, the units come gold-fin treated as standard, ensuring protection in areas close to the sea and user-oriented functions ensure end-users comfort and confidence in use.

Special features• True“all-in-one”monobloc

• Extensivewarranty,3yearsasstandardor5yearswithLGapprovedinstallerscheme

• SimpletouseselectionprogramtoselecttherightTherma-Vforyourproject

• Weathercompensationincludedasstandardforoptimumefficiency

• Pressurecontrolreinforcesheatingperformancebyoperatinginstableconditionevenatlowambienttemperature

• Emergencyback-upheatingincludedasstandard

• Quietoperationthroughoptimisedfan

• “Gold-fin”treatedasstandardforcoastalregions&areasofhighpollution

• HighefficiencyA-classcirculationpump

Page 29: Air Source Heat Pump - SOLFEX

29

Cost* Efficiency

Electricity cost: 0.135 £/kWh Therma V 7kW COP 4.3 (A7/W35)

Natural gas cost: 0.042 £/kWh Therma V 7kW COP 3.12 (A-7/W45)

Oil cost: 0.64 £/kWh Electrical heater COP 1

*based on EST prices 2014 Oil/Gas boiler COP 0.9

LG Electronics Air Conditioning and Energy Solutions invest heavily into research and development of their product portfolio. HVAC Equipment destined for the European market undergoes vigorous testing in LG’s Energy Lab based in Lille, France, the area chosen due to its challenging climate. The units are tested here for a minimum of a year before they are released into the market.

Many air-to-water heat pumps have been installed across the UK providing energy and financial savings for end users. Therma V is ideally suited to under floor heating systems and/or low temperature radiators as well as heating domestic hot water. The below graph demonstrates the cost saving advantages over traditional heating systems.

Comparison of Energy Cost per 1kWh of Thermal Energy

0.15

£/kWh

0.10

0.05

0.00Gas Boiler

48% lower running cost @ A7/W35

36% lower running cost @ A7/W35

Oil Boiler Electrical Heating

Domestic Multi Residential Industrial

Leisure

0.64

0.135

0.0420.0430.031

Page 30: Air Source Heat Pump - SOLFEX

30

3kW 5kW 7kW 9kW 12kW 14kW 16kW 12kW 14kW 16kW

HM031M.U42 HM051M.U42 HM071M.U42 HM091M.U42 HM121M.U32 HM141M.U32 HM161M.U32 HM123M.U32 HM143M.U32 HM163M.U32

Power Supply

Phase = 1 1 1 1 1 1 1 3 3 3

V = 220-240 220-240 220-240 220-240 220-240 220-240 220-240 380-415 380-415 380-415

Hz = 50 50 50 50 50 50 50 50 50 50

Nominal ConditionAir 7ºC Flow 30/35ºC

Heating Output: kW 3 4.99 7 9 12 14 16 12 14 16

Electrical Input: kW 0.73 1.13 1.63 2.2 2.67 3.15 3.81 2.67 3.15 3.81

COP: 4.1 4.4 4.3 4.1 4.49 4.44 4.2 4.49 4.44 4.2

Performance Air 7ºC Flow 40/45ºC

Heating Output: kW 2.75 4.58 6.41 8.25 11 12.83 14.6 11.28 13.16 15.41

Electrical Input: kW 0.85 1.33 1.9 2.44 3.18 3.8 4.45 3.31 3.92 4.62

COP: 3.24 3.44 3.37 3.38 3.46 3.38 3.28 3.41 3.36 3.34

Performance Air -7ºC Flow 30/35ºC

Heating Output: kW 2.45 4.07 5.71 7.34 9.8 9.8 13.01 9.82 11.41 13.26

Electrical Input: kW 0.95 1.48 2.12 2.72 3.55 3.55 4.93 3.56 4.22 5.29

COP: 2.58 2.75 2.69 2.70 2.76 2.76 2.64 2.76 2.70 2.51

Performance Air -7ºC Flow 40/45ºC

Heating Output: kW 2.17 3.62 3.62 6.51 8.73 10.31 11.48 8.92 10.38 12.13

Electrical Input: kW 1.04 1.62 1.62 2.96 4.02 4.7 5.16 4.11 4.77 5.65

COP: 2.09 2.23 2.23 2.20 2.17 2.19 2.22 2.17 2.18 2.15

Water Side

Heat Exchanger Type: Brazed plate HEX

Max Permissible Water Press. Bar 3

Nominal Water Flow Rate: l/min 8.6 14.3 20.1 25.8 34.4 40.1 45.9 34.4 40.1 45.9

Minimum Water Volume: l 20 20

Pressure Drop at Heat Ex: kPa 8.25 10.18 11.54 11.71 14.5 16.2 18.52 14.5 16.2 18.52

Pipe Connection: Inch 1" 1”

Fan Info

Quantity: - 1 1 2

Airflow Rate: m3/min 32 50 60 60 60 x 2

Output Power: W 124 124 124 x2

Refrigerant Side

Compressor Type: - Hermetic, Brushless DC motor Hermetic, Brushless DC motor

Oil: FVC68D FVC68D

Compressor Power: kW 1.5 2.1 2.1 2.1 4

Refrigerant Type: - R410A R410A

Refrigerant Factory Charge: g 750 1200 1450 1600 2200

Electrical Info

Running Current: MAX, A 10 13 14 15 25 11

Starting Current: A 2 2

Recommended Fuse Size: A 20 20 20 20 32 20

Sound InfoSound Pressure Level dBA 47 51 52 52 53

Sound Power Level dBA 55 63 65 65 67

Dimensions: HWD 834x950x330 907x1239x390 907x1239x390 1450x1239x390

Weight: kg 61 97 98 99 141

Operating RangeAmbient (A2W): °C -20 ~ 30 -20 ~ 35 -20 ~ 35

Leaving Water: °C 20 ~ 57 15 ~ 57 15 ~ 57

LG Electronics Technical Data

Page 31: Air Source Heat Pump - SOLFEX

31

3kW 5kW 7kW 9kW 12kW 14kW 16kW 12kW 14kW 16kW

HM031M.U42 HM051M.U42 HM071M.U42 HM091M.U42 HM121M.U32 HM141M.U32 HM161M.U32 HM123M.U32 HM143M.U32 HM163M.U32

Power Supply

Phase = 1 1 1 1 1 1 1 3 3 3

V = 220-240 220-240 220-240 220-240 220-240 220-240 220-240 380-415 380-415 380-415

Hz = 50 50 50 50 50 50 50 50 50 50

Nominal ConditionAir 7ºC Flow 30/35ºC

Heating Output: kW 3 4.99 7 9 12 14 16 12 14 16

Electrical Input: kW 0.73 1.13 1.63 2.2 2.67 3.15 3.81 2.67 3.15 3.81

COP: 4.1 4.4 4.3 4.1 4.49 4.44 4.2 4.49 4.44 4.2

Performance Air 7ºC Flow 40/45ºC

Heating Output: kW 2.75 4.58 6.41 8.25 11 12.83 14.6 11.28 13.16 15.41

Electrical Input: kW 0.85 1.33 1.9 2.44 3.18 3.8 4.45 3.31 3.92 4.62

COP: 3.24 3.44 3.37 3.38 3.46 3.38 3.28 3.41 3.36 3.34

Performance Air -7ºC Flow 30/35ºC

Heating Output: kW 2.45 4.07 5.71 7.34 9.8 9.8 13.01 9.82 11.41 13.26

Electrical Input: kW 0.95 1.48 2.12 2.72 3.55 3.55 4.93 3.56 4.22 5.29

COP: 2.58 2.75 2.69 2.70 2.76 2.76 2.64 2.76 2.70 2.51

Performance Air -7ºC Flow 40/45ºC

Heating Output: kW 2.17 3.62 3.62 6.51 8.73 10.31 11.48 8.92 10.38 12.13

Electrical Input: kW 1.04 1.62 1.62 2.96 4.02 4.7 5.16 4.11 4.77 5.65

COP: 2.09 2.23 2.23 2.20 2.17 2.19 2.22 2.17 2.18 2.15

Water Side

Heat Exchanger Type: Brazed plate HEX

Max Permissible Water Press. Bar 3

Nominal Water Flow Rate: l/min 8.6 14.3 20.1 25.8 34.4 40.1 45.9 34.4 40.1 45.9

Minimum Water Volume: l 20 20

Pressure Drop at Heat Ex: kPa 8.25 10.18 11.54 11.71 14.5 16.2 18.52 14.5 16.2 18.52

Pipe Connection: Inch 1" 1”

Fan Info

Quantity: - 1 1 2

Airflow Rate: m3/min 32 50 60 60 60 x 2

Output Power: W 124 124 124 x2

Refrigerant Side

Compressor Type: - Hermetic, Brushless DC motor Hermetic, Brushless DC motor

Oil: FVC68D FVC68D

Compressor Power: kW 1.5 2.1 2.1 2.1 4

Refrigerant Type: - R410A R410A

Refrigerant Factory Charge: g 750 1200 1450 1600 2200

Electrical Info

Running Current: MAX, A 10 13 14 15 25 11

Starting Current: A 2 2

Recommended Fuse Size: A 20 20 20 20 32 20

Sound InfoSound Pressure Level dBA 47 51 52 52 53

Sound Power Level dBA 55 63 65 65 67

Dimensions: HWD 834x950x330 907x1239x390 907x1239x390 1450x1239x390

Weight: kg 61 97 98 99 141

Operating RangeAmbient (A2W): °C -20 ~ 30 -20 ~ 35 -20 ~ 35

Leaving Water: °C 20 ~ 57 15 ~ 57 15 ~ 57

Page 32: Air Source Heat Pump - SOLFEX

32

Hitachi

Hitachi are well known for developing well-engineered products across the world. The air to water heat pump range is no exception. The range consists of monobloc (Yutaki-M), split (Yutaki-S) and high temperature (Yutaki-S80) units with outputs from 5kW to 24kW and exceptional performance characteristics with the energy efficiency of the units ranging from 400% to 500%*.

Hitachi can provide a heating and hot water solution to most properties in the UK whether it is for a small apartment or terrace house, larger detached houses or small commercial premises. The Yutaki range from Hitachi can save approximately 50% on fuel bills when compared to oil and LPG boilers.

*Based on CoP at 7/35 and in line with BS EN 14511

Special features• Vastrangeofproductoptionstoinclude:

5kWto24kWYutaki-S 7.5kWto14kWYutaki-M 10kW,12,kWand14kWYutaki-S80 (hightemperature)

• Industryleadingefficiencies–CoPof7kWYutaki-Mmodelis4.42(@A7/W35)

• Lowstartingcurrentonstart-up–Only1Amp

• Waterflowtemperaturerangefrom55°C,60°Cand80°Cdependingonsolutionrequired

• HitachiDChighpressurescrollcompressor

• Allunitsareinverterdriven–Heatpumpmodulatestheoutputtomatchheatloadofpropertythusmaximisingefficiency

• EnergyefficientonandoffperiodsutilisingEconomy7andEconomy10tariffs

• 5yearHitachiwarranty,asstandard

• Operationdownto-20°C

Page 33: Air Source Heat Pump - SOLFEX

33

InstallationCompany: ESTRenewablesLimited

Property Type: 4 bedroom detached new build

Location: Buckshaw Village, Preston

Heat Pump: Hitachi RHUE3.0AVHN1

Design Temp: -2.2°C

Insulation Levels: High (New build insulation levels)

Heat Load: 6.5kW

Previous Heating Fuel: None

Solar Photovoltaics Installed: 16 x 250wp Enhance Photovoltaic P60M Black Modules

Case Study

When Mrs O’Donnell was designing her new property, she decided that the perfect compliment to the PV system that was to be installed on her property would be a heat pump.

However, because of the lack of garden space, ground source was immediately removed from the equation. This left an air source heat pump as the most viable piece of equipment to install.

Provision had already been made to ensure that the radiators installed in the property were much larger than would be traditionally installed. This ensured that the heat pump installation would be able to run at a comfortable 45°C even at the coldest points of the year, without flow temperature back up from another heating source.

Whilst financial incentives were not the driving force behind looking at renewable heating, the renewable heat incentive payments were a welcome bonus. At the present time, without the benefit of inflationary percentages, the air source heat pump system will benefit Mrs O’Donnell by £670.00 per annum. Based upon fuel savings and RHI payments on the air source heat pump alone, the payback will equate to around 10 years which has far exceeded the customers expectations.

Page 34: Air Source Heat Pump - SOLFEX

34

RHUE3.0AVHN1 RHUE6.0AVHNRAS4HVRNME-AFRWH-4.0FSVNFE

Power Supply

Phase = Single phase

V = 230

Hz = 50

Nominal ConditionAir 7ºC Flow 30/35ºC

Heating Output: kW 7.5 14 10

Electrical Input: kW 1.69 3.25 2.29

COP: 4.43 4.31 4.36

Performance Air 7ºC Flow 40/45ºC

Heating Output: kW 7.1 13.3 10

Electrical Input: kW 2.13 3.97 2.90

COP: 3.34 3.35 3.45

Performance Air -7ºC Flow 30/35ºC

Heating Output: kW 6.5 9.3 7.6

Electrical Input: kW 2.71 3.58 3.22

COP: 2.4 2.6 2.36

Performance Air -7ºC Flow 40/45ºC

Heating Output: kW 6.2 9 10

Electrical Input: kW 3.08 4.07 4.35

COP: 2.01 2.21 2.3

Water Side

Heat Exchanger Type: Brazed Plate

Max Permissible Water Press. Bar 1.0 3.6

Nominal Water Flow Rate: l/min 1.29 2.41 1.7

Minimum Water Volume: l 80 156 40

Pressure Drop at Heat Ex: kPa 6.8 12.0

Pipe Connection: Inch Flexible pipe (G 1" male)

Fan Info

Quantity: - 1 2 2

Airflow Rate: m³/min 68 100 80

Output Power: W 138 70+70

Refrigerant Side

Compressor Type: - Hermetic Scroll

Oil: FVC68D

Compressor Power: kW 1.38 2.5 3.0

Refrigerant Type: - R410A R410A & R134a

Refrigerant Factory Charge: kg 2.6kg 4.2kg3.9kg (RAS) 2.5kg (RWH)

Electrical Info

Running Current: MAX, A 7.5 17.6Outdoor = 9.2 Indoor = 12.5

Starting Current: A 2

Recommended Fuse Size: A 32 32Outdoor = 20Indoor = 32

Sound InfoSound Pressure Level dBA 49 52 46

Sound Power Level dBA 68 68 65

Dimensions: HWD 800 x 1250 x 440 1480 x 1250 x 444 ->

Weight: kg 110 159RAS = 107kg, RWH = 157kg

Operating RangeAmbient (A2W): °C -20°C to +35

Leaving Water: °C 20 ~ 60 20 ~ 55 20 ~ 80

Hitachi Technical Data

Page 35: Air Source Heat Pump - SOLFEX

35

RAS5HVRNME-AFRWH-5.0FSVNFE

RAS6HVRNME-AFRWH-6.0FSVNFE

Power Supply

Phase = Single Phase

V = 230

Hz = 50

Nominal ConditionAir 7ºC Flow 30/35ºC

Heating Output: kW 12 14

Electrical Input: kW 2.81 3.46

COP: 4.27 4.05

Performance Air 7ºC Flow 40/45ºC

Heating Output: kW 12 14

Electrical Input: kW 3.51 4.22

COP: 3.42 3.32

Performance Air -7ºC Flow 30/35ºC

Heating Output: kW 9.0 9.4

Electrical Input: kW 3.88 4.10

COP: 2.32 2.29

Performance Air -7ºC Flow 40/45ºC

Heating Output: kW 12 14

Electrical Input: kW 5.22 6.22

COP: 2.3 2.25

Water Side

Heat Exchanger Type: Brazed Plate

Max Permissible Water Press. bar 3.6

Nominal Water Flow Rate: l/min 2.1 2.4

Minimum Water Volume: l 50 50

Pressure Drop at Heat Ex: kPa 12.0

Pipe Connection: inch Flexible pipe (G 1" male)

Fan Info

Quantity: - 2 2

Airflow Rate: m³/min 90 100

Output Power: W 70+70

Refrigerant Side

Compressor Type: - Hermetic Scroll

Oil: FVC68D

Compressor Power: kW 3.0

Refrigerant Type: - R410A & R134a

Refrigerant Factory Charge: g 4.0kg (RAS) 2.5kg (RWH) 4.0kg (RAS) 2.5kg (RWH)

Electrical Info

Running Current: MAX, AOutdoor = 11.6 Indoor = 12.7

Outdoor = 14.5 Indoor = 14.7

Starting Current: A 2

Recommended Fuse Size: AOutdoor = 25 Indoor = 32

Outdoor = 25Indoor = 32

Sound InfoSound Pressure Level dBA 48 48

Sound Power Level dBA 67 67

Dimensions: HWDRAS = 1380mm x 950mm x 370mm , RWH = 706mm x 595mm x 695mm

Weight: kgRAS = 108kg, RWH = 162kg

RAS = 108kg, RWH = 162kg

Operating RangeAmbient (A2W): °C -20°C to +35

Leaving Water: °C 20 ~ 80

Page 36: Air Source Heat Pump - SOLFEX

36

Pric

e Li

st38 - AEC Prestige Packs

40 - AEC Components

43 - Samsung Prestige Packs

47 - Hitachi Prestige Packs

49 - Hitachi Components

50 - Hitachi Components

53 - LG Prestige Packs

57 - LG Components

66 - Heat Pump Accessories

70 - Pre Plumbed Cylinders

71 - Unvented Cylinders

72 - Open Vented Cylinders

73 - Direct Stainless Steel Buffers

74 - Indirect Stainless Steel Buffers

75 - Multi-Tapping Buffers

Page 37: Air Source Heat Pump - SOLFEX

37

AEC Prestige PacksDescription Part Code List PriceAECAEC5PRESTIGEAIRSOURCEHEATPUMPPACK £4,044.97

Carbon GreySolfex AEC-PHPK-001CG

AEC5 monobloc heat pump c/w controls CPS 955979Anti Vibration Feet PTS SOLAECPHPK1CInsulated Flexible Hose Set TP 955979Isolation Valves Military Green2 Port Valves Solfex AEC-PHPK-001OGGlycol CPS 761910Flow Meter with Filling / Flushing Valve PTS SOLAECPHPK1GIn-Line Magnetic Filter TP 761910Various Brassware Arctic White4-Pole Isolator Switch Solfex AEC-PHPK-001WHNeostat Room Thermostat CPS 955978

PTS SOLAECPHPK1WTP 955978

AEC5–CASEBASEANDCOILCORROSIONPROTECTION

£555.56

Carbon GreyCorrosion protection when utilized in aggressive environments

Solfex AEC-CBCP-5CGCPS 761887

Coastal or high pollution applications PTS SOLAECBCP5CGTP 761887

5 Year Anti-Corrosion Warranty Military GreenSolfex AEC-CBCP-5OGCPS 955957PTS SOLAECBCP5OGTP 955957

Arctic WhiteSolfex AEC-CBCP-5WHCPS 955956PTS SOLAECBCP5WHTP 955956

AEC5–HEATPUMPCASECOLOURSELECTOR £309.83Can be utilized with or without corrosion protection. Solfex AEC-CS-5Colours available conform to RAL colour matching system. CPS 761892Please contact Solfex Heat Pump Sales for further information. PTS SOLAECCS5

TP 761892

AEC9PRESTIGEAIRSOURCEHEATPUMPPACK £4,565.81Carbon Grey

Solfex AEC-PHPK-002CGAEC9 monobloc heat pump c/w controls CPS 761911Anti Vibration Feet PTS SOLAECPHPK2CInsulated Flexible Hose Set TP 761911Isolation Valves Military Green2 Port Valves Solfex AEC-PHPK-002OGGlycol CPS 955981Flow Meter with Filling / Flushing Valve PTS SOLAECPHPK2GIn-Line Magnetic Filter TP 955981Various Brassware Arctic White4-Pole Isolator Switch Solfex AEC-PHPK-002WHNeostat Room Thermostat CPS 955980

PTS SOLAECPHPK2WTP 955980

Page 38: Air Source Heat Pump - SOLFEX

38

AEC Prestige PacksDescription Part Code List PriceAEC

AEC9–CASEBASEANDCOILCORROSIONPROTECTION

£555.56

Carbon GreyCorrosion protection when utilized in aggressive environments

Solfex AEC-CBCP-9CGCPS 761889

Coastal or high pollution applications PTS SOLAECBCP9CGTP 761889

5 Year Anti-Corrosion Warranty Military GreenSolfex AEC-CBCP-9OGCPS 955959PTS SOLAECBCP9OGTP 955959

Arctic WhiteSolfex AEC-CBCP-9WHCPS 761888PTS SOLAECBCP9WHTP 761888

AEC9–HEATPUMPCASECOLOURSELECTOR £309.83Can be utilized with or without corrosion protection. Solfex AEC-CS-9Colours available conform to RAL colour matching system. CPS 955963Please contact Solfex Heat Pump Sales for further information. PTS SOLAECCS9

TP 955963

AEC9ENHANCEDPRESTIGEAIRSOURCEHEATPUMPPACK

£4,982.47

Carbon GreySolfex AEC-PHPK-003CG

AEC9e monobloc heat pump c/w controls CPS 955982Anti Vibration Feet PTS SOLAECPHPK3CInsulated Flexible Hose Set TP 955982Isolation Valves Military Green2 Port Valves Solfex AEC-PHPK-003OGGlycol CPS 761913Flow Meter with Filling / Flushing Valve PTS SOLAECPHPK3GIn-Line Magnetic Filter TP 761913Various Brassware Arctic White4-Pole Isolator Switch Solfex AEC-PHPK-003WHNeostat Room Thermostat CPS 761912

PTS SOLAECPHPK3WTP 761912

AEC9ENHANCED–CASEBASEANDCOILCORROSIONPROTECTION

£555.56

Carbon GreyCorrosion protection when utilized in aggressive environments

Solfex AEC-CBCP-9eGCPS 761891

Coastal or high pollution applications PTS SOLAECBCP9eGTP 761891

5 Year Anti-Corrosion Warranty Military GreenSolfex AEC-CBCP-9eOGCPS 955961PTS SOLAECBCP9eOGTP 955961

Arctic WhiteSolfex AEC-CBCP-9eWCPS 761890PTS SOLAECBCP9eWTP 761890

Page 39: Air Source Heat Pump - SOLFEX

39

Description Part Code List PriceAEC

AEC9ENHANCED–HEATPUMPCASECOLOURSELECTOR

£309.83

Can be utilized with or without corrosion protection. Solfex AEC-CS-9eColours available conform to RAL colour matching system. CPS 761895Please contact Solfex Heat Pump Sales for further information. PTS SOLAECCS9e

TP 761895

AMBIENTENERGYCOLLECTOR-5KW £3,438.54Carbon Grey

Power Supply Phase = Single Solfex AEC-5CGV = 220-240v CPS 955941Hz = 50Hz PTS SOLAEC5CG

Nominal Condition

Heating Output: kW 5.5 TP 955941

Air 7ºC Flow 35ºC

Electrical Input: kW 1.22 Military GreenCOP: 4.52 Solfex AEC-5OG

Performance Heating Output: kW 5 CPS 761873Air 7ºC Flow 45ºC

Electrical Input: kW 1.56 PTS SOLAEC5OGCOP: 3.21 TP 761873

Performance Heating Output: kW 4.5Air -7ºC Flow 35ºC

Electrical Input: kW 1.32 Arctic WhiteCOP: 3.4 Solfex AEC-5WH

Performance Heating Output: kW 4.5 CPS 955940Air -7ºC Flow 45ºC

Electrical Input: kW 2.01 PTS SOLAEC5WHCOP: 2.24 TP 955940

Water Side Heat Exchanger Type:

Alfa Laval Plate heat exchanger

Max Permissible Water Press.

bar 3

Nominal Water Flow Rate:

l/min 15.72

Minimum Water Volume:

l 20

Pressure Drop at Heat Ex:

- 0.23 Bar @ 2.72 (L/min)

Pipe Connection: inch 1” BSP male thread

Fan Info Quantity: - 1Airflow Rate: m3/min 72.6Output Power: W 0.105

Refrigerant Side Compressor Type:

- Hermetic twin rotary

Oil: POECompressor Power:

kW 1.1

Refrigerant Type: - R410ARefrigerant Factory Charge:

kg 1.7

Electrical Info Running Current: A 13Starting Current: A 3Recommended Fuse Size:

A 16

Sound Info Sound Pressure Level

- 45dBA @ 1 metre

Sound Power Level

dBA 54

Dimensions: HWD(mm)

706, 395, 980

Weight: kg 65kgOperating Range Ambient (A2W): °C -15 to +35

Leaving Water: °C max 55

AEC Components

Page 40: Air Source Heat Pump - SOLFEX

40

Description Part Code List PriceAEC

AMBIENTENERGYCOLLECTOR-9KW £3,959.38Carbon Grey

Power Supply Phase = Single Solfex AEC-9CGV = 220-240v CPS 955944Hz = 50Hz PTS SOLAEC9CG

Nominal Condition

Heating Output: kW 9 TP 955944

Air 7ºC Flow 35ºC

Electrical Input: kW 2.55 Military GreenCOP: 3.45 Solfex AEC-9OG

Performance Heating Output: kW 9 CPS 761875Air 7ºC Flow 45ºC

Electrical Input: kW 2.75 PTS SOLAEC9OGCOP: 3.24 TP 761875

Performance Heating Output: kW 8Air -7ºC Flow 35ºC

Electrical Input: kW 3.11 Arctic WhiteCOP: 2.57 Solfex AEC-9WH

Performance Heating Output: kW 8 CPS 955943Air -7ºC Flow 45ºC

Electrical Input: kW 3.81 PTS SOLAEC9WHCOP: 2.1 TP 955943

Water Side Heat Exchanger Type:

Alfa Laval Plate heat exchanger

Max Permissible Water Press.

bar 3

Nominal Water Flow Rate:

l/min 25.12

Minimum Water Volume:

l 20

Pressure Drop at Heat Ex:

- 0.19 Bar @ 35 (L/min)

Pipe Connection: inch 1” BSP male thread

Fan Info Quantity: - 1Airflow Rate: m3/min 72.6Output Power: kW 0.105

Refrigerant Side Compressor Type:

- Hermetic twin rotary

Oil: POECompressor Power:

kW 2.9

Refrigerant Type: - R410ARefrigerant Factory Charge:

kg 2.4

Electrical Info Running Current: A 23Starting Current: A 5Recommended Fuse Size:

A 25

Sound Info Sound Pressure Level

- 48dBA @ 1 metre

Sound Power Level

dBA 57

Dimensions: HWD (mm)

1012, 395, 1032

Weight: kg 85kgOperating Range Ambient (A2W): °C -15 to +35

Leaving Water: °C max 55

AEC Components

Page 41: Air Source Heat Pump - SOLFEX

41

Description Part Code List PriceAECAMBIENTENERGYCOLLECTOR-9KWENHANCED

Carbon Grey £4,376.04Power Supply Phase = Single Solfex AEC-9eCG

V = 220-240v CPS 955946Hz = 50Hz PTS SOLAEC9eCG

Nominal Condition

Heating Output: kW 9 TP 955946

Air 7ºC Flow 35ºC

Electrical Input: kW 2.55COP: 3.45 Military Green

Performance Heating Output: kW 9 Solfex AEC-9eOGAir 7ºC Flow 45ºC

Electrical Input: kW 2.75 CPS 955949COP: 3.24 PTS SOLAEC9eOG

Performance Heating Output: kW 8 TP 955949Air -7ºC Flow 35ºC

Electrical Input: kW 3.11COP: 2.57 Arctic White

Performance Heating Output: kW 8 Solfex AEC-9eWHAir -7ºC Flow 45ºC

Electrical Input: kW 3.81 CPS 761876COP: 2.1 PTS SOLAEC9eWH

Water Side Heat Exchanger Type:

Alfa Laval Plate heat exchanger

TP 761876

Max Permissible Water Press.

bar 3

Nominal Water Flow Rate:

l/min 25.12

Minimum Water Volume:

l 20

Pressure Drop at Heat Ex:

- 0.19 Bar @ 35 (L/min)

Pipe Connection: inch 1” BSP male thread

Fan Info Quantity: - 1Airflow Rate: m3/min 72.6Output Power: kW 0.105

Refrigerant Side Compressor Type:

- Hermetic twin rotary

Oil: POECompressor Power:

kW 2.9

Refrigerant Type: - R410ARefrigerant Factory Charge:

kg 2.4

Electrical Info Running Current: A 23Starting Current: A 5Recommended Fuse Size:

A 25

Sound Info Sound Pressure Level

48dBA @ 1 metre

Sound Power Level

dBA 57

Dimensions: HWD (mm)

1012, 395,1300

Weight: kg 100Operating Range Ambient (A2W): - -15°C to +35°C

Leaving Water: °C max 55

AEC Components

Page 42: Air Source Heat Pump - SOLFEX

42

Samsung Prestige PacksDescription Part Code List PriceSamsung

SAMSUNGEHS9kWPRESTIGEAIRSOURCEHEATPUMPPACK

£2,871.55

SAMSUNG EHS HP-RC090MHXEA 9KW HEAT PUMP Solfex SAM-PHPK-001Control Kit (HP-MIM-E03A) CPS 761896Anti Vibration Feet PTS SOLSAMPHPK01Insulated Flexible Hose Set TP 761896Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch

SAMSUNGEHS9kWPRESTIGEAIRSOURCEHEATPUMPPACK+90LBUFFERTANK

£3,347.24

Solfex SAM-PHPK-001AYou will require a SOLMB090 buffer tank if the flow rate of your installation will not achieve 20lpm (RC090) or 30lpm (RC160)

CPS 955966

The tank will also be required if the overall system volume is less than 20ltrs

PTS SOLSAMPHPK1A

When utilizing a buffer tank additional Glycol will be required. Please contact Solfex HP Technical prior to order for advice if required

TP 955966

SAMSUNGEHSWARRANTYEXTENSION–9kW £237.68Total parts and labour allowance warranty period of 7 years Solfex HP-WARR-EXT-9To be eligible the warranty extension must be purchased CPS 908495at time of heat pump order PTS SOLHPWAR709

TP 908495

HP-RC090MHXEA–CASEBASEANDCOILCORROSIONPROTECTION

£427.35

Corrosion protection when utilized in aggressive environments

SolfexSAM-CBCP-9KW

Coastal or high pollution applications CPS 7618845 Year Anti-Corrosion Warranty PTS SOLSACBC9KW

TP 761884

HP-RC090MHXEA–HEATPUMPCASECOLOURSELECTOR

£309.83

Can be utilized with or without corrosion protection. Solfex SAM-CS-9KWColours available conform to RAL colour matching system. CPS 955955Please contact Solfex Heat Pump Sales for further PTS SOLSAMCS9KWinformation. TP 955955

SAMSUNGEHS16kWPRESTIGEAIRSOURCEHEATPUMPPACK

£4,172.76

SAMSUNG EHS HP-RC160MHXEA 16KW HEAT PUMP Solfex SAM-PHPK-002Control Kit (HP-MIM-E03A) CPS 761897Anti Vibration Feet PTS SOLSAMPHPK02Flexible Hose Set TP 761897Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch

Page 43: Air Source Heat Pump - SOLFEX

43

Samsung Prestige Packs

SAMSUNGEHSHEATPUMPCONTROLKIT £427.63Power Supply Ø = 1 Solfex HP-MIM-E03A

V = 220-240 CPS 908494Hz = 50 PTS HPMIME03A

Weight Net:3.5kg TP 908494Gross:5.7kg

Dimensions Net:

290 x 342 x 110mm (W x H x D)

Gross:

330 x 430 x 170mm (W x H x D)

External Input/Output Booster Heater:

AC 230V (Max 20A)

Back up Heater / Boiler:

AC 230V (Max 0.5A)

Water Pump:AC 230V (Max 2A)2 way or 3 way

Valve:AC 230V (Max 0.5A / 120W)

Room Thermostat:AC 230V (Max 10mA)

Solar Pump:AC 230V (Max 10mA)

Description Part Code List PriceSamsungSAMSUNGEHS16kWPRESTIGEAIRSOURCEHEATPUMPPACK+90LBUFFERTANK

£4,893.11

Solfex SAM-PHPK-002AYou will require a SOLMB090 buffer tank if the flow rate of your installation will not achieve 20lpm (RC090) or 30lpm (RC160)

CPS 761898

The tank will also be required if the overall system volume is less than 20ltrs

PTS SOLSAMPHPK2A

When utilizing a buffer tank additional Glycol will be required. Please contact Solfex HP Technical prior to order for advice if required

TP 761898

SAMSUNGEHSWARRANTYEXTENSION–16kW £374.35Total parts and labour allowance warranty period of 7 years Solfex HP-WARR-EXT-16To be eligible the warranty extension must be purchased CPS 132220at time of heat pump order PTS SOLHPWAR716

TP 132220

HP-RC160MHXEA–CASEBASEANDCOILCORROSIONPROTECTION

£555.56

Corrosion protection when utilized in aggressive environments

SolfexSAM-CBCP-16KW

Coastal or high pollution applications CPS 9559545 Year Anti-Corrosion Warranty PTS SOLSACBC16KW

TP 955954

HP-RC160MHXEA–HEATPUMPCASECOLOURSELECTOR

£395.30

Can be utilized with or without corrosion protection. Solfex SAM-CS-16KWColours available conform to RAL colour matching system. CPS 956334Please contact Solfex Heat Pump Sales for further information.

PTSSOLSAMCS6KW

TP 956334

Page 44: Air Source Heat Pump - SOLFEX

44

Description Part Code List PriceSamsung

SAMSUNGEHSMONOBLOC9KWHEATPUMP £2,047.50Solfex HP-RC090MHXEA

Power Supply Phase =1 CPS 132219V =220-240V PTS HPRC090MHXEA

Hz =50 TP 132219Nominal Condition

²Cooling:10,000W / 34,100 Btu/h

Air 7ºC Flow 30/35ºC

Heating Output:9kWElectrical Input:2.09kW

COP:4.3PerformanceAir 7ºC Flow 40/45ºC

²EER (Cooling):3.5Heating Output:8.4kWElectrical Input:2.51kW

COP:3.35PerformanceAir -7ºC Flow 30/35ºC

³Heating:2,510WHeating Output:7.54kWElectrical Input:3.35kW

COP:2.25PerformanceAir -7ºC Flow 40/45ºC

ESEER:4.26 - Water Out at 7ºC

Heating Output:7.59kWElectrical Input:3.86kW

COP:1.97kWWater Side Heat Exchanger

Type:Brazed Plate Heat Exchanger

Required Water Press.

2.8 bar

Nominal Water Flow Rate:

20lpm

Minimum Water Volume:

20ltrs

Pressure Drop at Heat Ex:

10kPa

Pipe Connection:1" maleFan Info Quantity:One

Airflow Rate:50m³/minOutput Power:8.4kW

Refrigerant Side Compressor Type:Rotary InverterOil:POE

Compressor Power:

2.51kW

Refrigerant Type:R410ARefrigerant Factory

Charge:1.4kg

Electrical Info Max Running Current:

17.4A

Starting Current: 2ARecommended Fuse Size:

20A

Sound Info Sound Pressure Level

50dB(A)

Sound Power Level66dB(A)Net Dimensions HWD (mm) 998 x 940 x 330Net Weight: 75kgOperating Range Ambient (A2W): -20°C to 35°C

Leaving Water: 25 to 55°C

Samsung Components

Page 45: Air Source Heat Pump - SOLFEX

45

Description Part Code List PriceSamsungSAMSUNGEHSMONOBLOC16KWHEATPUMP £3,321.45Power Supply Phase =1 Solfex HP-RC160MHXEA

V =220-240V CPS 714426Hz =50 PTS HPRC160MHXEA

Nominal Condition

¹Heating:16,000W / 54,600 Btu/h

TP 714426

Air 7ºC Flow 30/35ºC

Heating Output:16kWElectrical Input:3.81kW

COP:4.2PerformanceAir 7ºC Flow 40/45ºC

¹COP (Heating):4.2Heating Output:15.1kWElectrical Input:4.58kW

COP:3.3PerformanceAir -7ºC Flow 30/35ºC

Cooling:13,100W / 44,700 Btu/h

Heating Output:12.28kWElectrical Input:5.64kW

COP:2.18PerformanceAir -7ºC Flow 40/45ºC

EER (Cooling):2.45Heating Output:12.01kWElectrical Input:6.08kW

COP:1.98Water Side Heat Exchanger

Type:Required Water

Press.2.8 bar

Nominal Water Flow Rate:

30lpm

Minimum Water Volume:

20ltrs

Pressure Drop at Heat Ex:

15kPa

Pipe Connection:1" maleFan Info Quantity:Two

Airflow Rate:100m³/minOutput Power:14.9kW

Refrigerant Side Compressor Type:Rotary InverterOil:POE

Compressor Power:

4.6kW

Refrigerant Type:R410ARefrigerant Factory

Charge:2.2kg

Electrical Info Max Running Current:

30A

Starting Current:2ARecommended Fuse Size:

32A

Sound Info Sound Pressure Level

53dB(A)

Sound Power Level70dB(A)Net Dimensions HWD (mm) 1,420 x 940 x 330Net Weight: 103kgOperating Range Ambient (A2W): -20°C to 35°C

Leaving Water: 25°C to 55°C

Samsung Components

Page 46: Air Source Heat Pump - SOLFEX

46

Hitachi Prestige PacksHitachi

Description Part Code List PriceHITACHIYUTAKI-M7.5kW/3HPPRESTIGEHEATPUMPPACK

£4,593.44

Hitachi Yutaki-M RHUE3.0AVHN1 MonoBloc ATW Heat Pump

SolfexHIT-PHPK-001

Hitachi Yutaki-M Control Kit CPS 931702Anti Vibration Feet PTS SOLHITPHPK1Flexible Hose Set TP 931702Isolation Valves2 Port Zone ValvesFlow Meter with Filling / Flushing ValveIn-Line Magnetic Filter4-Pole Isolator SwitchBuffer Tank

HIT-RHUE3.0AVHN1–CASEBASEANDCOILCORROSIONPROTECTION

£427.35

Corrosion protection when utilized in aggressive environments

Solfex HIT-CBCP-7.5

Coastal or high pollution applications CPS 7618805 Year Anti-Corrosion Warranty PTS SOLHICBCP7.5

TP 761880

HIT-RHUE3.0AVHN1–HEATPUMPCASECOLOURSELECTOR

£309.83

Can be utilized with or without corrosion protection. Solfex HIT-CS-7.5Colours available conform to RAL colour matching system.

CPS761882

Please contact Solfex Heat Pump Sales for further information.

PTS SOLHICS7.5

TP 761882

HITACHIYUTAKI-M14kW/6HPPRESTIGEHEATPUMPPACK

£5,752.49

Hitachi Yutaki-M RHUE6.0AVHN1 MonoBloc ATW Heat Pump

SolfexHIT-PHPK-002

Hitachi Yutaki-M Control Kit CPS 931703Anti Vibration Feet PTS SOLHITPHPK2Flexible Hose Set TP 931703Isolation Valves2 Port Zone ValvesFlow Meter with Filling / Flushing ValveIn-Line Magnetic Filter4-Pole Isolator SwitchBuffer Tank

HIT-RHUE6.0AVHN–CASEBASEANDCOILCORROSIONPROTECTION

£555.56

Corrosion protection when utilized in aggressive environments

SolfexHIT-CBCP-14

Coastal or high pollution applications CPS 7618815 Year Anti-Corrosion Warranty PTS SOLHICBCP14

TP 761881

HIT-RHUE6.0AVHN–HEATPUMPCASECOLOURSELECTOR

£395.30

Can be utilized with or without corrosion protection. Solfex HIT-CS-14Colours available conform to RAL colour matching system.

CPS955952

Please contact Solfex Heat Pump Sales for further information.

PTS SOLHICS14KW

TP 955952

Page 47: Air Source Heat Pump - SOLFEX

47

Hitachi Prestige PacksHitachi

Description Part Code List PriceHITACHIYUTAKI-S806HPPRESTIGEHEATPUMPPACK

£8,362.86

HITACHI YUTAKI-S80 6HP OUTDOOR UNIT Solfex HIT-PHPK-S80-001HITACHI YUTAKI-S80 6HP INDOOR UNIT CPS 931704HITACHI YUTAKI-S80 HEAT PUMP SYSTEM CONTROL PACK

PTSSOLHIPHPKS80

Anti Vibration Feet TP 931704Isolation ValvesFlow Meter with Filling / Flushing ValveIn-Line Magnetic Filter4-Pole Isolator SwitchBuffer Tank

HIT-RAS-6HVRNME-AF–CASEBASEANDCOILCORROSIONPROTECTION

£555.56

Corrosion protection when utilized in aggressive environments

SolfexHIT-CBCP-S80

Coastal or high pollution applications CPS 9559515 Year Anti-Corrosion Warranty PTS SOLHICBCPS80

TP 955951

HIT-RAS-6HVRNME-AF–HEATPUMPCASECOLOURSELECTOR

£395.30

Can be utilized with or without corrosion protection. Solfex HIT-CS-S80Colours available conform to RAL colour matching system.

CPS761883

Please contact Solfex Heat Pump Sales for further information.

PTS SOLHICS-S80

TP 761883

HIT-RWH-6.0FSNFE–HEATPUMPCASECOLOURSELECTOR

£287.26

Can be utilized with or without corrosion protection. Solfex HIT-CS-S80INColours available conform to RAL colour matching system.

CPS955953

Please contact Solfex Heat Pump Sales for further information.

PTS SOLHICSS80IN

TP 955953

Page 48: Air Source Heat Pump - SOLFEX

48

Hitachi ComponentsHitachi

Description Part Code List PriceHitachiYutaki-M7.5kW/3HPMonoBlocATWHeatPump

£3,161.46

Power Supply Ø = 1 Solfex HIT-RHUE3.0AVHN1

V = 230 CPS 737632Hz = 50 PTS SOLHITRHUE3

Nominal Condition Air 7ºC Flow 30/35ºC

Heating Output: 7.5kW TP 737632Electrical Input: 1.69kWCOP: 4.43

Performance Air 7ºC Flow 40/45ºC

Heating Output: 7.1kWElectrical Input: 2.13kWCOP: 3.34

Performance Air -7ºC Flow 30/35ºC

Heating Output: 6.kWElectrical Input: 2.71kWCOP: 2.4

Performance Air -7ºC Flow 40/45ºC

Heating Output: 6.2kWElectrical Input: 3.18kWCOP: 2.01

Water Side Heat Exchanger Type:

Brazed Plate

Max Permissible Water Press.

1.0 bar

Nominal Water Flow Rate:

22lpm

Minimum Water Volume:

100ltrs

Pressure Drop at Heat Ex:

6.8kPa at Nominal Condition

Pipe Connection: 1” MaleFan Info Quantity: One

Airflow Rate: 68m³/minOutput Power: 138W

Refrigerant Side Compressor Type: Hermetic ScrollOil: FVC68DCompressor Power:

1.38kW

Refrigerant Type: R410ARefrigerant Factory Charge:

2.6kg

Electrical Info Running Current: 7.5A (excludes pump)

Starting Current: 2ARecommended Fuse Size:

32A

Sound Info Sound Pressure Level

49dB (A) at 1m from front of unit

Sound Power Level68dB (A)Dimensions: 800 x 1250 x

440mm (H x W x D)

Weight: 110kg NetOperating Range Ambient (A2W): Heating:

-20~37.5ºC (WB)Leaving Water: Heating: 20~60ºC

Page 49: Air Source Heat Pump - SOLFEX

49

Hitachi ComponentsHitachi

Description Part Code List PriceHitachiYutaki-M14kW/6HPMonoBlocATWHeatPump

£4,242.45

Power Supply Ø = 1 Solfex HIT-RHUE6.0AVHN

V = 230 CPS 931701Hz = 50 PTS SOLHITRHUE6

Nominal Condition Air 7ºC Flow 30/35ºC

Heating Output:14kW TP 931701Electrical Input:3.25kW

COP:4.31

Performance Air 7ºC Flow 40/45ºC

Heating Output:13.3kWElectrical Input:3.97kW

COP:3.35Performance Air -7ºC Flow 30/35ºC

Heating Output:9.3kWElectrical Input:3.58kW

COP:2.60Performance Air -7ºC Flow 40/45ºC

Heating Output:9kWElectrical Input:4.07kW

COP:2.21Water Side Heat Exchanger

Type:Brazed Plate

Max Permissible Water Press.

1.0 bar

Nominal Water Flow Rate:

40lpm

Minimum Water Volume:

156ltrs

Pressure Drop at Heat Ex:

12.0kPa at Nominal Condition

Pipe Connection:1” MaleFan Info Quantity:Two

Airflow Rate:100m³/minOutput Power:70W + 70W

Refrigerant Side Compressor Type:DC Inverter DrivenOil:FVC68D

Compressor Power:

2.5kW

Refrigerant Type:R410ARefrigerant Factory

Charge:4.2kg

Electrical Info Running Current:17.6A (excludes pump)

Starting Current:2ARecommended

Fuse Size:32A

Sound Info Sound Pressure Level

52dB (A) at 1m from front of unit

Sound Power Level68dB (A)Dimensions: 1480 x 1250 x

444mm (H x Wx D)

Weight: 159kg NetOperating Range Ambient (A2W):Heating: -20 -

+35ºCLeaving Water:Heating: 20~55ºC

HITACHIYUTAKI-MHEATPUMPSYSTEMCONTROLPACK

£531.64

Power Supply V = 230Vac +10%, -15%, 50Hz Solfex HIT-ATW-CPA-02Hz = 50 CPS 737629

Degree of Protection

IP30(with terminal covers) PTS SOLHIAWCPA02

Dimensions 215.5 W x 147 H x 57.5 D mm (with terminal covers) TP 737629

Page 50: Air Source Heat Pump - SOLFEX

50

HitachiDescription Part Code List PriceHITACHIYUTAKI-S806HPOUTDOORUNIT £1,951.10Power Supply Ø = 1 Solfex HIT-RAS-

6HVRNME-AFV = 230 CPS 737631Hz = 50 PTS SOLHITRAS6

Nominal Condition Air 7ºC Flow 30/35ºC

Heating Output: 14.0kW TP 737631Electrical Input: 3.46kWCOP: 4.05

When connected to HIT-RWH-6.0FSNFEPerformance Air 7ºC Flow 40/45ºC

Heating Output: 14.0kWElectrical Input: 4.22kWCOP: 3.32

When connected to HIT-RWH-6.0FSNFEPerformance Air -7ºC Flow 30/35ºC

Heating Output: 9.4kWElectrical Input: 4.14kWCOP: 2.29

When connected to HIT-RWH-6.0FSNFEPerformance Air -7ºC Flow 40/45ºC

Heating Output: 14.0kWElectrical Input: 6.22kWCOP: 2.25

When connected to HIT-RWH-6.0FSNFEFan Info Quantity: Two

Airflow Rate: 100m³/minOutput Power: 70W + 70W

Refrigerant Gas Pipe Required: 5/8”Liquid Pipe Required:

3/8”

Compressor Power:

2.5kW

Refrigerant Type: R410ARefrigerant Factory Charge:

4.00kg

Heat Exchanger Type:

Multi-Pass Cross-Finned Tube

Electrical Info Running Current: 14.5A (excludes pump)

Starting Current: <10ARecommended Fuse Size:

25A

Sound Info Sound Pressure Level

48dB (A) at 1m from front of unit

Sound Power Level67dB (A)Dimensions: 1380 x 950 x

370mm (H x W x D)

Weight: 104kg NetOperating Range Ambient (A2W): Heating:

-20~35ºC (WB)

Hitachi Components

Page 51: Air Source Heat Pump - SOLFEX

51

HitachiDescription Part Code List PriceHITACHIYUTAKI-S806HPINDOORUNIT £5,264.96Power Supply Ø = 1 Solfex HIT-RWH-

6.0FSNFEV = 230 CPS 737633Hz = 50 PTS SOLHITRWH6

Refrigerant Gas Pipe Required: 5/8” TP 737633Liquid Pipe Required:

3/8”

Pipe Length: 30mCompressor Power:

3.0kW

Refrigerant Type: R-134aRefrigerant Factory Charge:

2.5kg

Electrical Info Running Current: 14.7AMax Current: 31.0ARecommended Fuse Size:

32A

Sound Info Sound Pressure Level

41dB (A) @ A7 & W55/65°C

Sound Power Level57dB (A)Dimensions: 595 x 706 x

695mm (W x H x D)

Weight: 162kg NetOperating Range Water Outlet

Temperature:30~80°C

Internal Temperature:

5~35ºC

Water Side Heat Exchanger Type:

Stainless Steel

Expansion Vessel Volume:

12ltr

Nominal Water Flow Rate:

40lpm

Minimum Water Volume:

200ltrs

Heating Pipe Connection:

1” Male

DHW Pipe Connection:

3/4” Male

Pump Input Power: 75W

HITACHIYUTAKI-S80HEATPUMPSYSTEMCONTROLPACK

£177.22

Dimensions: Height: 118mm Solfex HIT-PC-S80TEWidth: 118mm CPS 931699Depth: 22mm PTS SOLHIPCS80TEWeight: 0.5kg TP 931699

HITACHIYUTAKIS/S80WIRELESSROOMCONTROLUNIT

£159.50

Dimensions: Room Stat HWD 88 x 131 x 22 Solfex HIT-ATW-RTU-02Receiver HWD 88 x 83 x 27 CPS 956335Weight: 0.6kg PTS SOLHIAWRTU02

TP 956335

Hitachi Components

Page 52: Air Source Heat Pump - SOLFEX

52

LG Prestige PacksDescription Part Code List PriceLGLGTHERMA-V3kWPRESTIGEAIRSOURCEHEATPUMPPACK

£2,717.98

Solfex LG-PHPK-001LG Therma-V HM031M.U42 Monobloc c/w controls CPS 761914Anti Vibration Feet PTS SOLLGPHPK001Insulated Flexible Hose Set TP 761914Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

HM031M.U42–CASEBASEANDCOILCORROSIONPROTECTION

£427.35

Corrosion protection when utilized in aggressive environments

Solfex LG-CBCP-3KW

Coastal or high pollution applications CPS 9559685 Year Anti-Corrosion Warranty PTS SOLLGCBCP3KW

TP 955968

HM031M.U42–HEATPUMPCASECOLOURSELECTOR

£309.83

Can be utilized with or without corrosion protection.Colours available conform to RAL colour matching system. Solfex LG-CS-3KWPlease contact Solfex Heat Pump Sales for further information. CPS 955972

PTS SOLLGCS3KWTP 955972

LGTHERMA-V5kWPRESTIGEAIRSOURCEHEATPUMPPACK

£3,485.70

Solfex LG-PHPK-002LG Therma-V HM051M.U42 Monobloc c/w controls CPS 955984Anti Vibration Feet PTS SOLLGPHPK002Insulated Flexible Hose Set TP 955984Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

HM051M.U42–CASEBASEANDCOILCORROSIONPROTECTION

£427.35

Corrosion protection when utilized in aggressive environments

Solfex LG-CBCP-5KW

Coastal or high pollution applications CPS 7618995 Year Anti-Corrosion Warranty PTS SOLLGCBCP5KW

TP 761899

HM051M.U42–HEATPUMPCASECOLOURSELECTOR

£309.83

Can be utilized with or without corrosion protection. Solfex LG-CS-5KWColours available conform to RAL colour matching system. CPS 761903Please contact Solfex Heat Pump Sales for further information. PTS SOLLGCS5KW

TP 761903

Page 53: Air Source Heat Pump - SOLFEX

53

Description Part Code List PriceLGLGTHERMA-V7kWPRESTIGEAIRSOURCEHEATPUMPPACK

£3,642.70

Solfex LG-PHPK-003LG Therma-V HM071M.U42 Monobloc c/w controls CPS 955985Anti Vibration Feet PTS SOLLGPHPK003Insulated Flexible Hose Set TP 955985Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

HM071M.U42–CASEBASEANDCOILCORROSIONPROTECTION

£427.35

Corrosion protection when utilized in aggressive environments

Solfex LG-CBCP-7KW

Coastal or high pollution applications CPS 955969

5 Year Anti-Corrosion WarrantyPTS

SOLLGCBCP7KW

TP 955969HM071M.U42–HEATPUMPCASECOLOURSELECTOR £309.83Can be utilized with or without corrosion protection.Colours available conform to RAL colour matching system. Solfex LG-CS-7KWPlease contact Solfex Heat Pump Sales for further information. CPS 955973

PTS SOLLGCS7KWTP 955973

LGTHERMA-V9kWPRESTIGEAIRSOURCEHEATPUMPPACK

£3,912.70

Solfex LG-PHPK-004LG Therma-V HM091M.U42 Monobloc c/w controls CPS 761916Anti Vibration Feet PTS SOLLGPHPK004Insulated Flexible Hose Set TP 761916Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

HM091M.U42–CASEBASEANDCOILCORROSIONPROTECTION

£427.35

Corrosion protection when utilized in aggressive environments

Solfex LG-CBCP-9KW

Coastal or high pollution applications CPS 761900

5 Year Anti-Corrosion WarrantyPTS

SOLLGCBCP9KW

TP 761900

HM091M.U42–HEATPUMPCASECOLOURSELECTOR £309.83Can be utilized with or without corrosion protection. Solfex LG-CS-9KWColours available conform to RAL colour matching system. CPS 955974Please contact Solfex Heat Pump Sales for further information. PTS SOLLGCS9KW

TP 955974

LG Prestige Packs

Page 54: Air Source Heat Pump - SOLFEX

54

Description Part Code List PriceLGLGTHERMA-V12kWPRESTIGEAIRSOURCEHEATPUMPPACK

£5,056.18

Solfex LG-PHPK-005LG Therma-V HM121M.U32 Monobloc c/w controls CPS 761917Anti Vibration Feet

PTS SOLLGPHPK005

Insulated Flexible Hose Set TP 761917Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

HM121M.U32–CASEBASEANDCOILCORROSIONPROTECTION

£555.56

Corrosion protection when utilized in aggressive environments

Solfex LG-CBCP-12KW

Coastal or high pollution applications CPS 9559705 Year Anti-Corrosion Warranty PTS SOLLGCBCP12

TP 955970HM121M.U32–HEATPUMPCASECOLOURSELECTOR

£395.30

Can be utilized with or without corrosion protection.Colours available conform to RAL colour matching system. Solfex LG-CS-12KWPlease contact Solfex Heat Pump Sales for further information. CPS 761905

PTS SOLLGCS12KWTP 761905

LGTHERMA-V14kWPRESTIGEAIRSOURCEHEATPUMPPACK

£5,435.18

Solfex LG-PHPK-006LG Therma-V HM141M.U32 Monobloc c/w controls CPS 761918Anti Vibration Feet PTS SOLLGPHPK006Insulated Flexible Hose Set TP 761918Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

HM141M.U32–CASEBASEANDCOILCORROSIONPROTECTION

£555.56

Corrosion protection when utilized in aggressive environments Solfex LG-CBCP-14KWCoastal or high pollution applications CPS 9559715 Year Anti-Corrosion Warranty PTS SOLLGCBCP14

TP 955971

HM141M.U32–HEATPUMPCASECOLOURSELECTOR

£395.30

Can be utilized with or without corrosion protection. Solfex LG-CS-14KWColours available conform to RAL colour matching system. CPS 955976Please contact Solfex Heat Pump Sales for further information. PTS SOLLGCS14KW

TP 955976

LG Prestige Packs

Page 55: Air Source Heat Pump - SOLFEX

55

Description Part Code List PriceLG

LGTHERMA-V16kWPRESTIGEAIRSOURCEHEATPUMPPACK

£5,823.18

Solfex LG-PHPK-007LG Therma-V HM161M.U32 Monobloc c/w controls CPS 955988Anti Vibration Feet PTS SOLLGPHPK007Insulated Flexible Hose Set TP 955988Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

HM161M.U32–CASEBASEANDCOILCORROSIONPROTECTION

£555.56

Corrosion protection when utilized in aggressive environments

Solfex LG-CBCP-16KW

Coastal or high pollution applications CPS 7619025 Year Anti-Corrosion Warranty PTS SOLLGCBCP16

TP 761902HM161M.U32–HEATPUMPCASECOLOURSELECTOR

£395.30

Can be utilized with or without corrosion protection.Colours available conform to RAL colour matching system. Solfex LG-CS-16KWPlease contact Solfex Heat Pump Sales for further information. CPS 761907

PTS SOLLGCS16KWTP 761907

LG Prestige Packs

Page 56: Air Source Heat Pump - SOLFEX

56

Description Part Code List PriceLGLGTHERMA-V3KWMONOBLOCKAIRSOURCEHEATPUMP

£2,213.00

Solfex LG-HM031M.U42

Power Supply

Phase = 1V = 220-240 CPS 761919

Hz = 50Nominal Condition Air 7ºC Flow 30/35ºC

Heating Output: kW 3 PTS SOLLGHM031MElectrical Input: kW 0.73

COP: 4.1TP 761919

Performance Air 7ºC Flow 40/45ºC

Heating Output: kW 2.75Electrical Input: kW 0.85

COP: 3.24Performance Air -7ºC Flow 30/35ºC

Heating Output: kW 2.45Electrical Input: kW 0.95

COP: 2.58Performance Air -7ºC Flow 40/45ºC

Heating Output: kW 2.17Electrical Input: kW 1.04

COP: 2.09

Water SideHeat Exchanger

Type: Brazed plate HEXMax Permissible

Water Press. bar 3Nominal Water

Flow Rate: l/min 5.6Minimum Water

Volume: l 20Pressure Drop at

Heat Ex: kPa 8.25Pipe Connection: inch 1”

Fan Info Quantity: - 1

Airflow Rate:m3/min 32

Output Power: W 124

Refrigerant Side Compressor Type: -

Hermetic, Brushless DC motor

Oil: FVC68DCompressor

Power: kW 1.5Refrigerant Type: - R410A

Refrigerant Factory Charge: g 750

Electrical Info Running Current:MAX,

A 10Starting Current: A 2Recommended

Fuse Size: A 20

Sound InfoSound Pressure

Level dBA 47Sound Power

Level dBA 55Dimensions: HWD 834x950x330Weight: kg 61Operating Range Ambient (A2W): C -20 ~ 30

Leaving Water: C 20 ~ 57

LG Components

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

Page 57: Air Source Heat Pump - SOLFEX

57

Description Part Code List PriceLG

LGTHERMA-V5KWMONOBLOCKAIRSOURCEHEATPUMP

£2,950.00

Solfex LG-HM051M.U42Power Supply Phase = 1

V = 220-240 CPS 955989Hz = 50

Nominal Condition Air 7ºC Flow 30/35ºC

Heating Output: kW 4.99 PTS SOLLGHM051MElectrical Input: kW 1.13

COP: 4.4TP 955989

Performance Air 7ºC Flow 40/45ºC

Heating Output: kW 4.58Electrical Input: kW 1.33

COP: 3.44Performance Air -7ºC Flow 30/35ºC

Heating Output: kW 4.07Electrical Input: kW 1.48

COP: 2.75Performance Air -7ºC Flow 40/45ºC

Heating Output: kW 3.62Electrical Input: kW 1.62

COP: 2.23

Water SideHeat Exchanger

Type: Brazed plate HEXMax Permissible

Water Press. bar 3Nominal Water

Flow Rate: l/min 14.3Minimum Water

Volume: l 20Pressure Drop at

Heat Ex: kPa 10.18Pipe Connection: inch 1”

Fan Info Quantity: - 1

Airflow Rate:m3/min 50

Output Power: W 124

Refrigerant Side Compressor Type: -

Hermetic, Brushless DC motor

Oil: FVC68DCompressor

Power: kW 2.1Refrigerant Type: - R410A

Refrigerant Factory Charge: g 1200

Electrical Info Running Current:MAX,

A 13Starting Current: A 2Recommended

Fuse Size: A 20

Sound InfoSound Pressure

Level dBA 51Sound Power

Level dBA 63Dimensions: HWD 907x1239x390Weight: kg 97Operating Range Ambient (A2W): C -20 ~ 35

Leaving Water: C 15 ~ 57

LG Components

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

Page 58: Air Source Heat Pump - SOLFEX

58

Description Part Code List PriceLGLGTHERMA-V7KWMONOBLOCKAIRSOURCEHEATPUMP

£3,107.00

Solfex LG-HM071M.U42Power Supply Phase = 1

V = 220-240 CPS 761921Hz = 50

Nominal Condition Air 7ºC Flow 30/35ºC

Heating Output: kW 7 PTS SOLLGHM071MElectrical Input: kW 1.63

COP: 4.3TP 761921

Performance Air 7ºC Flow 40/45ºC

Heating Output: kW 6.41Electrical Input: kW 1.9

COP: 3.37Performance Air -7ºC Flow 30/35ºC

Heating Output: kW 5.71Electrical Input: kW 2.12

COP: 2.69Performance Air -7ºC Flow 40/45ºC

Heating Output: kW 3.62Electrical Input: kW 1.62

COP: 2.23

Water SideHeat Exchanger

Type: Brazed plate HEXMax Permissible

Water Press. bar 3Nominal Water

Flow Rate: l/min 20.1Minimum Water

Volume: l 20Pressure Drop at

Heat Ex: kPa 11.54Pipe Connection: inch 1”

Fan Info Quantity: - 1

Airflow Rate:m3/min 60

Output Power: W 124

Refrigerant Side Compressor Type: -

Hermetic, Brushless DC motor

Oil: FVC68DCompressor

Power: kW 2.1Refrigerant Type: - R410A

Refrigerant Factory Charge: g 1450

Electrical Info Running Current:MAX,

A 14Starting Current: A 2Recommended

Fuse Size: A 20

Sound InfoSound Pressure

Level dBA 52Sound Power

Level dBA 65Dimensions: HWD 907x1239x390Weight: kg 98Operating Range Ambient (A2W): C -20 ~ 35

Leaving Water: C 15 ~ 57

LG Components

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

Page 59: Air Source Heat Pump - SOLFEX

59

Description Part Code List PriceLG

LGTHERMA-V9KWMONOBLOCKAIRSOURCEHEATPUMP

£3,377.00

Solfex LG-HM091M.U42Power Supply Phase = 1

V = 220-240 CPS 955991Hz = 50

Nominal Condition Air 7ºC Flow 30/35ºC

Heating Output: kW 9 PTS SOLLGHM091MElectrical Input: kW 2.2

COP: 4.1TP 955991

Performance Air 7ºC Flow 40/45ºC

Heating Output: kW 8.25Electrical Input: kW 2.44

COP: 3.38Performance Air -7ºC Flow 30/35ºC

Heating Output: kW 7.34Electrical Input: kW 2.72

COP: 2.7Performance Air -7ºC Flow 40/45ºC

Heating Output: kW 6.51Electrical Input: kW 2.96

COP: 2.2

Water SideHeat Exchanger

Type: Brazed plate HEXMax Permissible

Water Press. bar 3Nominal Water

Flow Rate: l/min 25.8Minimum Water

Volume: l 20Pressure Drop at

Heat Ex: kPa 11.71Pipe Connection: inch 1”

Fan Info Quantity: - 1

Airflow Rate:m3/min 60

Output Power: W 124

Refrigerant Side Compressor Type: -

Hermetic, Brushless DC motor

Oil: FVC68DCompressor

Power: kW 2.1Refrigerant Type: - R410A

Refrigerant Factory Charge: g 1600

Electrical Info Running Current:MAX,

A 15Starting Current: A 2Recommended

Fuse Size: A 20

Sound InfoSound Pressure

Level dBA 52Sound Power

Level dBA 65Dimensions: HWD 907x1239x390Weight: kg 99Operating Range Ambient (A2W): °C -20 ~ 35

Leaving Water: °C 15 ~ 57

LG Components

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

Page 60: Air Source Heat Pump - SOLFEX

60

Description Part Code List PriceLGLGTHERMA-V12KWMONOBLOCKAIRSOURCEHEATPUMP

£4,475.00

Solfex LG-HM121M.U32Power Supply Phase = 1

V = 220-240 CPS 761922Hz = 50

Nominal Condition Air 7ºC Flow 30/35ºC

Heating Output: kW 12 PTS SOLLGHM121MElectrical Input: kW 2.67

COP: 4.49TP 761922

Performance Air 7ºC Flow 40/45ºC

Heating Output: kW 11Electrical Input: kW 3.18

COP: 3.46Performance Air -7ºC Flow 30/35ºC

Heating Output: kW 9.8Electrical Input: kW 3.55

COP: 2.76Performance Air -7ºC Flow 40/45ºC

Heating Output: kW 8.73Electrical Input: kW 4.02

COP: 2.17

Water SideHeat Exchanger

Type: Brazed plate HEXMax Permissible

Water Press. bar 3Nominal Water

Flow Rate: l/min 34.4Minimum Water

Volume: l 20Pressure Drop at

Heat Ex: kPa 14.5Pipe Connection: inch 1”

Fan Info Quantity: - 2

Airflow Rate:m3/min 60 x 2

Output Power: W 124 x2

Refrigerant Side Compressor Type: -

Hermetic, Brushless DC motor

Oil: FVC68DCompressor

Power: kW 4Refrigerant Type: - R410A

Refrigerant Factory Charge: g 2200

Electrical Info Running Current:MAX,

A 25Starting Current: A 2Recommended

Fuse Size: A 32

Sound InfoSound Pressure

Level dBA 53Sound Power

Level dBA 67Dimensions: HWD 1450x1239x390Weight: kg 141Operating Range Ambient (A2W): °C -20 ~ 35

Leaving Water: °C 15 ~ 57

LG Components

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

Page 61: Air Source Heat Pump - SOLFEX

61

Description Part Code List PriceLG

LGTHERMA-V14KWMONOBLOCKAIRSOURCEHEATPUMP

£4,854.00

Solfex LG-HM141M.U32Power Supply Phase = 1

V = 220-240 CPS 761923Hz = 50

Nominal Condition Air 7ºC Flow 30/35ºC

Heating Output: kW 14 PTS SOLLGHM141MElectrical Input: kW 3.15

COP: 4.44TP 761923

Performance Air 7ºC Flow 40/45ºC

Heating Output: kW 12.83Electrical Input: kW 3.8

COP: 3.38Performance Air -7ºC Flow 30/35ºC

Heating Output: kW 9.8Electrical Input: kW 3.55

COP: 2.76Performance Air -7ºC Flow 40/45ºC

Heating Output: kW 10.31Electrical Input: kW 4.7

COP: 2.19

Water SideHeat Exchanger

Type: Brazed plate HEXMax Permissible

Water Press. bar 3Nominal Water

Flow Rate: l/min 40.1Minimum Water

Volume: l 20Pressure Drop at

Heat Ex: kPa 16.2Pipe Connection: inch 1”

Fan Info Quantity: - 2

Airflow Rate:m3/min 60 x 2

Output Power: W 124 x2

Refrigerant Side Compressor Type: -

Hermetic, Brushless DC motor

Oil: FVC68DCompressor

Power: kW 4Refrigerant Type: - R410A

Refrigerant Factory Charge: g 2200

Electrical Info Running Current:MAX,

A 25Starting Current: A 2Recommended

Fuse Size: A 32

Sound InfoSound Pressure

Level dBA 53Sound Power

Level dBA 67Dimensions: HWD 1450x1239x390Weight: kg 141Operating Range Ambient (A2W): °C -20 ~ 35

Leaving Water: °C 15 ~ 57

LG Components

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

Page 62: Air Source Heat Pump - SOLFEX

62

Description Part Code List PriceLGLGTHERMA-V16KWMONOBLOCKAIRSOURCEHEATPUMP

£5,242.00

Solfex LG-HM161M.U32Power Supply Phase = 1

V = 220-240 CPS 955993Hz = 50

Nominal Condition Air 7ºC Flow 30/35ºC

Heating Output: kW 16 PTS SOLLGHM161MElectrical Input: kW 3.81

COP: 4.2TP 955993

Performance Air 7ºC Flow 40/45ºC

Heating Output: kW 14.6Electrical Input: kW 4.45

COP: 3.28Performance Air -7ºC Flow 30/35ºC

Heating Output: kW 13.01Electrical Input: kW 4.93

COP: 2.64Performance Air -7ºC Flow 40/45ºC

Heating Output: kW 11.48Electrical Input: kW 5.16

COP: 2.22

Water SideHeat Exchanger

Type: Brazed plate HEXMax Permissible

Water Press. bar 3Nominal Water

Flow Rate: l/min 45.9Minimum Water

Volume: l 20Pressure Drop at

Heat Ex: kPa 18.52Pipe Connection: inch 1”

Fan Info Quantity: - 2

Airflow Rate:m3/min 60 x 2

Output Power: W 124 x2

Refrigerant Side Compressor Type: -

Hermetic, Brushless DC motor

Oil: FVC68DCompressor

Power: kW 4Refrigerant Type: - R410A

Refrigerant Factory Charge: g 2200

Electrical Info Running Current:MAX,

A 25Starting Current: A Soft startRecommended

Fuse Size: A 32

Sound InfoSound Pressure

Level dBA 53Sound Power

Level dBA 67Dimensions: HWD 1450x1239x390Weight: kg 141Operating Range Ambient (A2W): °C -20 ~ 35

Leaving Water: °C 15 ~ 57

LG Components

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

Page 63: Air Source Heat Pump - SOLFEX

63

Description Part Code List PriceLG

LGTHERMA-V12KWMONOBLOCKAIRSOURCEHEATPUMP(3PHASE)

£4,699.00

Solfex LG-HM123M.U32Power Supply Phase = 3

V = 380-415 CPS 955996Hz = 50

Nominal Condition Air 7ºC Flow 30/35ºC

Heating Output: kW 12 PTS SOLLGHM123MElectrical Input: kW 2.67

COP: 4.49TP 955996

Performance Air 7ºC Flow 40/45ºC

Heating Output: kW 11.28Electrical Input: kW 3.31

COP: 3.41Performance Air -7ºC Flow 30/35ºC

Heating Output: kW 9.82Electrical Input: kW 3.56

COP: 2.76Performance Air -7ºC Flow 40/45ºC

Heating Output: kW 8.92Electrical Input: kW 4.11

COP: 2.17

Water SideHeat Exchanger

Type: Brazed plate HEXMax Permissible

Water Press. bar 3Nominal Water

Flow Rate: l/min 34.4Minimum Water

Volume: l 20Pressure Drop at

Heat Ex: kPa 14.5Pipe Connection: inch 1"

Fan Info Quantity: - 2

Airflow Rate:m3/min 60 x 2

Output Power: W 124 x2

Refrigerant Side Compressor Type: -

Hermetic, Brushless DC motor

Oil: FVC68DCompressor

Power: kW 4Refrigerant Type: - R410A

Refrigerant Factory Charge: g 2200

Electrical Info Running Current:MAX,

A 11Starting Current: A 2Recommended

Fuse Size: A 20

Sound InfoSound Pressure

Level dBA 53Sound Power

Level dBA 67Dimensions: HWD 1450x1239x390Weight: kg 141Operating Range Ambient (A2W): °C -20 ~ 35

Leaving Water: °C 15 ~ 57

LG Components

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

Page 64: Air Source Heat Pump - SOLFEX

64

Description Part Code List PriceLGLGTHERMA-V14KWMONOBLOCKAIRSOURCEHEATPUMP(3PHASE)

£5,097.00

Solfex LG-HM143M.U32Power Supply Phase = 3

V = 380-415 CPS 955997Hz = 50

Nominal Condition Air 7ºC Flow 30/35ºC

Heating Output: kW 14 PTS SOLLGHM143MElectrical Input: kW 3.15

COP: 4.44TP 955997

Performance Air 7ºC Flow 40/45ºC

Heating Output: kW 13.16Electrical Input: kW 3.92

COP: 3.36Performance Air -7ºC Flow 30/35ºC

Heating Output: kW 11.41Electrical Input: kW 4.22

COP: 2.7Performance Air -7ºC Flow 40/45ºC

Heating Output: kW 10.38Electrical Input: kW 4.77

COP: 2.18

Water SideHeat Exchanger

Type: Brazed plate HEXMax Permissible

Water Press. bar 3Nominal Water

Flow Rate: l/min 40.1Minimum Water

Volume: l 20Pressure Drop at

Heat Ex: kPa 16.2Pipe Connection: inch 1”

Fan Info Quantity: - 1

Airflow Rate:m3/min 60 x 2

Output Power: W 124 x2

Refrigerant Side Compressor Type: -

Hermetic, Brushless DC motor

Oil: FVC68DCompressor

Power: kW 4Refrigerant Type: - R410A

Refrigerant Factory Charge: g 2200

Electrical Info Running Current:MAX,

A 11Starting Current: A 2Recommended

Fuse Size: A 20

Sound InfoSound Pressure

Level dBA 53Sound Power

Level dBA 67Dimensions: HWD 1450x1239x390Weight: kg 141Operating Range Ambient (A2W): °C -20 ~ 35

Leaving Water: °C 15 ~ 57

LG Components

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

Page 65: Air Source Heat Pump - SOLFEX

65

LG-PHLTB SANITARY TANK KIT FOR MONOBLOC £169.00In order to use a domestic hot water with an LG Heat Pump, Solfex LG-PHLTBthis accessory must be purchased. CPS 762272Please contact Solfex Technical for further details PTS SOLLGPHLTB

TP 762272

Description Part Code List PriceLG

LGTHERMA-V16KWMONOBLOCKAIRSOURCEHEATPUMP(3PHASE)

£5,504.00

Solfex LG-HM163M.U32Power Supply Phase = 3

V = 380-415 CPS 955998Hz = 50

Nominal Condition Air 7ºC Flow 30/35ºC Heating Output: kW 16

PTS SOLLGHM163M

Electrical Input: kW 3.81COP: 4.2 TP 955998

Performance Air 7ºC Flow 40/45ºC

Heating Output: kW 15.41Electrical Input: kW 4.62

COP: 3.34Performance Air -7ºC Flow 30/35ºC

Heating Output: kW 13.26Electrical Input: kW 5.29

COP: 2.51Performance Air -7ºC Flow 40/45ºC

Heating Output: kW 12.13Electrical Input: kW 5.65

COP: 2.15

Water SideHeat Exchanger

Type: Brazed plate HEXMax Permissible

Water Press. bar 3Nominal Water

Flow Rate: l/min 45.9Minimum Water

Volume: l 20Pressure Drop at

Heat Ex: kPa 18.52Pipe Connection: inch 1”

Fan Info Quantity: - 1

Airflow Rate:m3/min 60 x 2

Output Power: W 124 x2

Refrigerant Side Compressor Type: -

Hermetic, Brushless DC motor

Oil: FVC68DCompressor

Power: kW 4Refrigerant Type: - R410A

Refrigerant Factory Charge: g 2200

Electrical Info Running Current:MAX,

A 11Starting Current: A 2Recommended

Fuse Size: A 20

Sound InfoSound Pressure

Level dBA 53Sound Power

Level dBA 67Dimensions: HWD 1450x1239x390Weight: kg 141Operating Range Ambient (A2W): °C -20 ~ 35

Leaving Water: °C 15 ~ 57

LG Components

Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired

Page 66: Air Source Heat Pump - SOLFEX

66

Heat Pump AccessoriesHeat Pump Accessories

Description Part Code List PriceFLEXIFOOTFIXINGKIT £11.90

Solfex HP-FF-FIXPACKFor the fixation of the ASHP to the Flexi Foot 600 CPS 908486Delivery: 4x nut, 4x bolt, 4x spring washer PTS SOLHPFFFIXPK

TP 908486

FLEXIFOOT600 £20.44Dimensions (L x W x H): 600mm x 185mm x 100mm Solfex HP-FF-600-SWeight: 7.6kg CPS 132210Max Load: 300kg PTS SOLHPFF600SDelivery: 1pc TP 132210

FLEXIFOOT600COMPLETEWITHFIXINGKIT £52.78Dimensions (L x W x H): 600mm x 185mm x 100mm Solfex HP-FF-600-S-KITWeight: 7.6kg CPS 762257Max Load: 300kg PTS SOLHPFF600KTDelivery: 1pc TP 762257FLEXI FOOT FIXING KITFor the fixation of the ASHP to the Flexi Foot 600Delivery: 4x nut, 4x bolt, 4x spring washer

AIRSOURCEHEATPUMPWALLMOUNTINGBRACKETWITHCROSSBAR

£96.84

Solfex HP-WMB-001Suitable for Samsung EHS Monobloc 9kW & 16kW units CPS 908474Delivery: 1pc PTS HPWMB001

TP 908474

ANTI-VIBRATIONMOUNTINGBOLTS £25.50M8 nuts and washers to suit wall mounting brackets Solfex HP-AVMB-001Delivery: 4pc CPS 761870

PTS SOLHPAVMB001TP 761870

22MMCOMPRESSIONFLUSH/FILLVALVE £23.10Solfex HP-FF588

Delivery: 1pc CPS 714398PTS HPFF588TP 714398

1”BSPFEMALE3PORTDIVERTERVALVE £49.98Solfex HP-DIV-1

Action: Spring return CPS 356217Delivery: 1pc PTS HPDIV1

TP 356217

Page 67: Air Source Heat Pump - SOLFEX

67

Heat Pump AccessoriesHeat Pump Accessories

Description Part Code List PriceINSULATEDFLEXIBLEASHPHOSEPAIR-750mmX28mm-1”FEMALE

£95.49

750mm Length Solfex HP-FLEXI-INS-119mm TC Insulation CPS 9559391” Female BSP Thread Fitting PTS SOLHPFLEXIN128mm Compression Fitting TP 955939

1”BSPFEMALEx1”BSPFEMALE1MFLEXIBLEBRAIDEDHOSE

£19.89

Solfex HP-FLEXI-1Delivery: 1pc CPS 714388

PTS HPFLEXI1TP 714388

1”HIGHTEMPERATUREGASKET £0.59Solfex HTGSKT-1

Delivery: 1pc CPS 956328PTS HTGSKT1TP 956328

28MMINLINEMAGNETICFILTERCOMPLETEWITHISOLATIONVALVES

£78.85

Solfex HP-FILT-28MMDelivery: 1pc CPS 372993

PTS SOLHPFILT28TP 372993

22MMCOMPRESSIONFULLBORELEVERARMVALVE(REDHANDLE)

£11.40

Solfex HP-VAL22RDelivery: 1pc CPS 522549

PTS HPVAL22RTP 522549

22MMCOMPRESSIONFULLBORELEVERARMVALVE(BLUEHANDLE)

£11.40

Solfex HP-VAL22BDelivery: 1pc CPS 908466

PTS HPVAL22BTP 908466

28MMCOMPRESSIONFULLBORELEVERARMVALVE(REDHANDLE)

£12.79

Solfex HP-VAL28RDelivery: 1pc CPS 714400

PTS HPVAL28RTP 714400

28MMCOMPRESSIONFULLBORELEVERARMVALVE(BLUEHANDLE)

£12.79

Solfex HP-VAL28BDelivery: 1pc CPS 714401

PTS HPVAL28BTP 714401

1”BSPFEMALEFLUSH/FILLVALVE&FLOWREGULATOR

£39.47

Solfex HP-FM1497Flow Rate: 8 - 38 lpm CPS 363241Delivery: 1pc PTS HPFM1497

TP 363241

Page 68: Air Source Heat Pump - SOLFEX

68

Heat Pump AccessoriesDescription Part Code List Price22MMCOMPRESSION2PORTVALVE £52.70

Solfex VAL-60524600Action: Spring return CPS 613505Delivery: 1pc PTS SOLVA6052460

TP 613505

28MMCOMPRESSION2PORTVALVE £44.54Solfex VAL-60424600

Action: Spring return CPS 762259Delivery: 1pc PTS SOLVA6042460

TP 762259

1”BSPMALEx22MMCOMPRESSIONADAPTER £4.59Solfex FIT-1100G002206FD

Brass fitting CPS 908459Delivery: each PTS 100G002206FD

TP 908459

1”BSPMALEx28MMCOMPRESSIONADAPTER £5.78Solfex FIT-2057

Brass fitting CPS 714391Delivery: each PTS FIT2057

TP 714391

1”BSPMALEx1”BSPMALESTRAIGHTNIPPLE £3.64Solfex FIT-1552G000606FD

Brass fitting CPS 908457Delivery: each PTS 1552G00606FD

TP 908457

TYFOCORLPROPYLENEGLYCOL £45.48Solfex TYFOL10LTR

Concentrate - ready to use - 10L PE Can CPS 714430Delivery: each PTS TYFOL10LTR

TP 714430

ACIsolatingSwitchNEW324P £24.75Solfex AC-NEW324P

4 Pole Switch disconnector IP66/77 CPS 956331Rated Operating Current - 32Amps PTS SOLACNEW324P

TP 956331

HTARMAFLEX £12.54Insulation material: Foamed EPDM rubber Solfex HT-19X28Pipe size: 28mm CPS 908489Insulation thickness: 19mm PTS HT19X28Min/Max surface temperature: -200°C - +150°C Class 1 resistance to flame speed in

TP 908489

accordance with BS 476 Part 7 - UV resistantDelivery: 2 Mtr length

HTARMAFLEX £15.30Insulation material: Foamed EPDM rubber Solfex HT-25X28Pipe size: 28mm CPS 132214Insulation thickness: 25mm PTS HT25X28Min/Max surface temperature: -200°C - +150°C Class 1 resistance to flame speed in

TP132214

accordance with BS 476 Part 7 - UV resistantDelivery: 2 Mtr length

Heat Pump Accessories

Page 69: Air Source Heat Pump - SOLFEX

69

Heat Pump AccessoriesDescription Part Code List Price

OWLINTUITION-HPW £276.30

With the new OWL Intuition Smart Heating Control home owners can….

Solfex OWL-TSE220-150

CPS 737636• Take control of their heating and hot water using any Internet connected device – desktop, laptop, tablet or even Smartphone and from they happen to be – at work, on holiday, even on the train

PTS SOLOWLSE2201

• Save up to 20% on their heating bills TP 737636• Use the OWL Intuition web dashboard to control their heating and hot water settings online

Comes complete with:Network Owl GatewayIntuition-Lc (Lge Sensors Pack)Intuition Relay Unit [RMT-6C]Intuition Room Sensor [RBT-3C]

SOLARCHECKMOBILCENTERKOMPAKTSOLARFILLING/FLUSHINGUNIT230VZUWA-P80

£533.27

Technical Specification Solfex FIL-134053V11UKPump Type: Self Priming Centrifugal Pump (dry run max 1 min) CPS 762260Max Flow Rate: 31 lpm PTS SOLFIL134053Max Pressure: 5.9 bar TP 762260Max Fluid Temp: 60 degrees CPower Supply 230V - 1.7m cable with plugTank Capacity: 30 litreHoses: 2 x 3mTelescopic Handle

HANDHELDREFRACTOMETER £117.70Solfex REF-402

For determination of glycol concentration CPS 163887Delivery: With carry case and manual PTS REF402

TP 163887

THROUGHWALLKIT £36.85Kit Contents Solfex HP-TWK-0012 x straight 320mm lengths. CPS 7622612 x custom slit elbows. PTS SOLHPTWK00119mm wall insulation with tough PVC coating. TP 762261Suitable for both 22mm and 28mm pipe

HEATMISERNeoStat-BLACKEDITION £86.25

Stunning design incorporating soft touch keysSolfex

UFH-CON-NEOSTAT-BK

Non Programmable, 5/2 Day, 7 Day and 24 Hour Programming

CPS 747095

5 Minute Program Intervals PTS SOLNEOSTATBKSelf Learning Optimum Start TP 747095

HEATMISERNeoStat-WHITEEDITION £86.25Stunning design incorporating soft touch keys Solfex UFH-CON-NEOSTATNon Programmable, 5/2 Day, 7 Day and 24 Hour Programming

CPS 747093

5 Minute Program Intervals PTS SOLNEOSTATWHSelf Learning Optimum Start TP 747093

Heat Pump Accessories

Page 70: Air Source Heat Pump - SOLFEX

70

Pre Plumbed CylindersPre Plumbed Heat Pump Cylinders

Description Part Code List Price180LSOLFEXSLIMLINEPRE-PLUMBEDHEATPUMPUNVENTEDCYLINDER

£1,743.63

Capacity: 180ltr Solfex HP-PP-180-SLIMHeight: 1790mm CPS 762262Approx Diameter: 575mm PTS SOLHPPP180SLWeight (empty): 46.3kg TP 762262Weight (full): 226.3kgStanding Losses: 2.01kWhr/24hrSurface Area of Coil: 3m²Vessel Warranty: 25yrsCylinder Components & Electronics Warranty:

2yrs

210LSOLFEXSLIMLINEPRE-PLUMBEDHEATPUMPUNVENTEDCYLINDER

£1,794.95

Capacity: 210ltr Solfex HP-PP-210-SLIMHeight: 1970mm CPS 956332Approx Diameter: 575mm PTS SOLHPPP210SLWeight (empty): 50.3kg TP 956332Weight (full): 260.3kgStanding Losses: 2.23kWhr/24hrSurface Area of Coil: 3m²Vessel Warranty: 25yrsCylinder Components & Electronics Warranty:

2yrs

250LSOLFEXPRE-PLUMBEDHEATPUMPUNVENTEDCYLINDER

£1,865.30

Capacity: 250ltr Solfex HP-PP-250Height: 1745mm CPS 762263Approx Diameter: 650mm PTS SOLHPPP250Weight (empty): 56.3kg TP 762263Weight (full): 306.3kgStanding Losses: 1.85kWhr/24hrSurface Area of Coil: 3m²Vessel Warranty: 25yrsCylinder Components & Electronics Warranty:

2yrs

300LSOLFEXPRE-PLUMBEDHEATPUMPUNVENTEDCYLINDER

£1,964.88

Capacity: 300ltr Solfex HP-PP-300Height: 1992mm CPS 956333Approx Diameter: 650mm PTS SOLHPPP300Weight (empty): 71.3kg TP 956333Weight (full): 371.3kgStanding Losses: 2.04kWhr/24hrSurface Area of Coil: 3m²Vessel Warranty: 25yrsCylinder Components & Electronics Warranty:

2yrs

Page 71: Air Source Heat Pump - SOLFEX

71

Unvented CylindersUnvented Heat Pump Cylinders

Description Part Code List Price

SOLFEXENERGYSYSTEMS180LCASEDINDIRECTUNVENTEDHEATPUMP&SOLARCYLINDER

£928.25

Size HxW: 1295 x 550mm Solfex SOLHP180Weight empty / full: 33 / 213 KG CPS 908462G3 Unvented Kit included PTS SOLHP180Standing losses: 1.40KWh/24h TP 908462Heat Pump Coil surface area: 1.36 M²Dedicated Solar Volume: 65L

SOLFEXENERGYSYSTEMS210LCASEDINDIRECTUNVENTEDHEATPUMP&SOLARCYLINDER

£981.13

Size HxW: 1483 x 550mm Solfex SOLHP210Weight empty / full: 38 / 248KG CPS 908465G3 Unvented Kit included PTS SOLHP210Standing losses: 1.60KWh/24hr TP 908465Heat Pump Coil surface area: 1.56 M²Dedicated Solar Volume: 75L

SOLFEXENERGYSYSTEMS250LCASEDINDIRECTUNVENTEDHEATPUMP&SOLARCYLINDER

£1,075.13

Size HxW: 1733 x 550mm Solfex SOLHP250Weight empty / full: 43 / 293 KG CPS 132192G3 Unvented Kit included PTS SOLHP250Standing losses: 1.75KWh/24hr TP 132192Heat Pump Coil surface area: 1.94 M²Dedicated Solar Volume: 90L

SOLFEXENERGYSYSTEMS300LCASEDINDIRECTUNVENTEDHEATPUMP&SOLARCYLINDER

£1,175.00

Size HxW: 2020 x 550mm Solfex SOLHP300Weight empty / full: 49 / 349 KG CPS 714403G3 Unvented Kit included PTS SOLHP300Standing losses: 1.93KWh/24hr TP 714403Heat Pump Coil surface area: 2.04 M²Dedicated Solar Volume: 105L

SOLFEXENERGYSYSTEMS400LCASEDINDIRECTUNVENTEDHEATPUMP&SOLARCYLINDER

£1,468.75

Size HxW: 2040 x 630mm Solfex SOLHP400Weight empty / full: 61 / 461 KG CPS 714404G3 Unvented Kit included PTS SOLHP400Standing losses: 3.33KWh/24hr TP 714404Heat Pump Coil surface area: 2.91 M²Dedicated Solar Volume: 130L

SOLFEXENERGYSYSTEMS180LCASEDINDIRECTUNVENTEDSLIMLINEHEATPUMPCYLINDER

£928.25

Size HxW: 1790 x 475mm Solfex SOLHP180SLIMWeight empty / full: 33 / 213 KG CPS 714394G3 Unvented Kit included PTS SOLHP180SLIMStanding losses: 2.01KWh/24hr TP 714394Heat Pump Coil surface area: 3.01 M²

SOLFEXENERGYSYSTEMS210LCASEDINDIRECTUNVENTEDSLIMLINEHEATPUMPCYLINDER

£981.13

Size HxW: 2005 x 475mm Solfex SOLHP210SLIMWeight empty / full: 37 / 247 KG CPS 762913G3 Unvented Kit included PTS SOLHP210SLIMStanding losses: 2.23KWh/24hr TP 762913Heat Pump Coil surface area: 3.01 M²

Page 72: Air Source Heat Pump - SOLFEX

72

Open Vented CylindersOpen Vented Heat Pump Cylinders

Description Part Code List Price180LCASEDINDIRECTOPENVENTEDHEATPUMP&SOLARCYLINDER

£806.44

Size HxW : 1295 x 550mm Solfex SOLHP180OVWeight empty / full : 33 / 213 KG CPS 762266Standing losses : 1.40KWh/24hr PTS SOLHP180OVHeat Pump Coil surface area : 1.36 M² TP 762266Dedicated Solar Volume : 65L

SOLFEXENERGYSYSTEMS210LCASEDINDIRECTOPENVENTEDHEATPUMP&SOLARCYLINDER

£854.23

Size HxW : 1483 x 550mm Solfex SOLHP210OVWeight empty / full : 38 / 248KG CPS 956336Standing losses : 1.60KWh/24hr PTS SOLHP210OVHeat Pump Coil surface area : 1.56 M² TP 956336Dedicated Solar Volume : 75L

SOLFEXENERGYSYSTEMS250LCASEDINDIRECTOPENVENTEDHEATPUMP&SOLARCYLINDER

£952.80

Size HxW : 1733 x 550mm Solfex SOLHP250OVWeight empty / full : 43 / 293 KG CPS 762267Standing losses : 1.75KWh/24hr PTS SOLHP25OVHeat Pump Coil surface area : 1.94 M² TP 762267Dedicated Solar Volume : 90L

SOLFEXENERGYSYSTEMS300LCASEDINDIRECTOPENVENTEDHEATPUMP&SOLARCYLINDER

£1,049.75

Size HxW : 2020 x 550mm Solfex SOLHP300OVWeight empty / full : 49 / 349 KG CPS 762268Standing losses : 1.93KWh/24hr PTS SOLHP30OVHeat Pump Coil surface area : 2.04 M² TP 762268Dedicated Solar Volume : 105L

SOLFEXENERGYSYSTEMS400LCASEDINDIRECTOPENVENTEDHEATPUMP&SOLARCYLINDER

£1,344.15

Size HxW : 2040 x 630mm Solfex SOLHP400OVWeight empty / full : 61 / 461 KG CPS 956338Standing losses : 3.33KWh/24hr PTS SOLHP40OVHeat Pump Coil surface area : 2.91 M² TP 956338Dedicated Solar Volume : 130L

SOLFEXENERGYSYSTEMS180LCASEDINDIRECTSLIMLINEOPENVENTEDHEATPUMPCYLINDER

£806.44

Size HxW : 1790 x 475mm Solfex SOLHP180SLIMOV

Weight empty / full : 33 / 213KG CPS 956340

Standing losses : 2.01KWh/24hr PTS SOLHP18SLIOV

Heat Pump Coil surface area : 3.01 M² TP 956340

SOLFEXENERGYSYSTEMS210LCASEDINDIRECTSLIMLINEOPENVENTEDHEATPUMPCYLINDER

£854.23

Size HxW : 2005 x 475mm Solfex SOLHP210SLIMOV

Weight empty / full : 37 / 247 KG CPS 956341

Standing losses : 2.23KWh/24hr PTS SOLHP21SLIOV

Heat Pump Coil surface area : 3.01 M² TP 956341

Page 73: Air Source Heat Pump - SOLFEX

73

Direct Stainless Steel BuffersDirect Stainless Steel Buffers

Description Part Code List PriceSOLFEXENERGYSYSTEMS90LCASEDDIRECTSTAINLESSBUFFERSTORE

£312.71

Capacity: 90L Solfex SOLDB090Height: 732mm CPS 132197Diameter: 550mm PTS SOLDB090Weight: 13kg empty / 103 kg full TP 132197Standing losses: 0.80kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 28mmHeat pump connections: 28mmThermostatic pockets: 2 (1x top & 1x bottom)

SOLFEXENERGYSYSTEMS120LCASEDDIRECTSTAINLESSBUFFERSTORE

£343.71

Capacity: 120LHeight: 920mm Solfex SOLDB120Diameter: 550mm CPS 908460Weight: 18kg empty / 138 kg full PTS SOLDB120Standing losses: 1.00kWhr/24hr TP 908460Max working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 28mmHeat pump connections: 28mmThermostatic pockets: 2 (1x top & 1x bottom)

SOLFEXENERGYSYSTEMS210LCASEDDIRECTSTAINLESSBUFFERSTORE

£415.19

Capacity: 210L Solfex SOLDB210Height: 1483 mm CPS 908463Diameter: 550mm PTS SOLDB210Weight: 28kg empty / 238 kg full TP 908463Standing losses: 1.60kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 28mmHeat pump connections: 28mmThermostatic pockets: 2 (1x top & 1x bottom)

SOLFEXENERGYSYSTEMS300LCASEDDIRECTSTAINLESSBUFFERSTORE

£508.62

Capacity: 300L Solfex SOLDB300Height: 2020mm CPS 714402Diameter: 550mm PTS SOLDB300Weight: 37kg empty / 337 kg full TP 714402Standing losses: 1.93kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 35mmHeat pump connections: 35mmThermostatic pockets: 2 (1x top & 1x bottom)

SOLFEXENERGYSYSTEMS400LCASEDDIRECTSTAINLESSBUFFERSTORE

£657.38

Capacity: 400L Solfex SOLDB400Height: 2030mm CPS 132196Diameter: 630mm PTS SOLDB400Weight: 51 kg empty / 451 kg full TP 132196Standing losses: 3.33kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 35mmHeat pump connections: 35mmThermostatic pockets: 2 (1x top & 1x bottom)

Page 74: Air Source Heat Pump - SOLFEX

74

Indirect Stainless Steel BuffersIndirect Stainless Buffer Stores

Description Part Code List PriceSOLFEXENERGYSYSTEMS120LCASEDINDIRECTSTAINLESSBUFFERSTORE

£453.52

Capacity: 120L Solfex SOLIB120Height: 920mm CPS 714393Diameter: 550mm PTS SOLIB120Weight: 22kg empty / 142 kg full TP 714393Standing losses: 1.00kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 28mmHeat pump connections: 28mmCoil connections: 22mmCoil surface area: 0.59m²Thermostatic pockets: 2 (1x top & 1x bottom)

SOLFEXENERGYSYSTEMS210LCASEDINDIRECTSTAINLESSBUFFERSTORE

£547.21

Capacity: 210L Solfex SOLIB210Height: 1483 mm CPS 326257Diameter: 550mm PTS SOLIB210Weight: 33 kg empty / 243 kg full TP 326257Standing losses: 1.60kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 28mmHeat pump connections: 28mmCoil connections: 22mmCoil surface area: 0.78m²Thermostatic pockets: 2 (1x top & 1x bottom)

SOLFEXENERGYSYSTEMS300LCASEDINDIRECTSTAINLESSBUFFERSTORE

£662.46

Capacity: 300L Solfex SOLIB300Height: 2020mm CPS 908471Diameter: 550mm PTS SOLIB300Weight: 44 kg empty / 344 kg full TP 908471Standing losses: 1.93kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 35mmHeat pump connections: 35mmCoil connections: 22mmCoil surface area: 0.78m²Thermostatic pockets: 2 (1x top & 1x bottom)

SOLFEXENERGYSYSTEMS400LCASEDINDIRECTSTAINLESSBUFFERSTORE

£754.68

Capacity: 400L Solfex SOLIB400Height: 2030mm CPS 908472Diameter: 630mm PTS SOLIB400Weight: 55 kg empty / 455 kg full TP 908472Standing losses: 3.33kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 35mmHeat pump connections: 35mmCoil connections: 22mmCoil surface area: 0.78m²Thermostatic pockets: 2 (1x top & 1x bottom)

Page 75: Air Source Heat Pump - SOLFEX

75

Multi-Tapping BuffersMulti-Tapping Stainless Buffer Stores

Description Part Code List PriceSOLFEXENERGYSYSTEMS90LCASEDDIRECTMULTI-TAPPINGSTAINLESSBUFFERSTORE

£384.73

Capacity: 90L Solfex SOLMB090Height: 740mm CPS 714405Diameter: 550mm PTS SOLMB090Weight: 13kg empty / 103 kg full TP 714405Standing losses: 0.80kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingConnections: 28mmThermostatic pockets: 2 (1x top & 1x bottom)

SOLFEXENERGYSYSTEMS120LCASEDDIRECTMULTI-TAPPINGSTAINLESSBUFFERSTORE

£418.56

Capacity: 120L Solfex SOLMB120Height: 930mm CPS 714392Diameter: 550mm PTS SOLMB120Weight: 18kg empty / 138 kg full TP 714392Standing losses: 1.00kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingConnections: 28mmThermostatic pockets: 2 (1x top & 1x bottom)

SOLFEXENERGYSYSTEMS210LCASEDDIRECTMULTI-TAPPINGSTAINLESSBUFFERSTORE

£496.62

Capacity: 210L Solfex SOLMB210Height: 1488 mm CPS 714395Diameter: 550mm PTS SOLMB210Weight: 28kg empty / 238 kg full TP 714395Standing losses: 1.60kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingConnections: 28mmThermostatic pockets: 2 (1x top & 1x bottom)

SOLFEXENERGYSYSTEMS250LCASEDDIRECTMULTI-TAPPINGSTAINLESSBUFFERSTORE

£574.50

Capacity: 250L Solfex SOLMB250Height: 1740 mm CPS 714399Diameter: 550mm PTS SOLMB250Weight: 32 kg empty / 282 kg full TP 714399Standing losses: 1.75kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingConnections: 35mmThermostatic pockets: 2 (1x top & 1x bottom)

SOLFEXENERGYSYSTEMS300LCASEDDIRECTMULTI-TAPPINGSTAINLESSBUFFERSTORE

£664.51

Capacity: 300L Solfex SOLMB300Height: 2025mm CPS 132195Diameter: 550mm PTS SOLMB300Weight: 37kg empty / 337 kg full TP 132195Standing losses: 1.93kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingConnections: 35mmThermostatic pockets: 2 (1x top & 1x bottom)

SOLFEXENERGYSYSTEMS400LCASEDDIRECTMULTI-TAPPINGSTAINLESSBUFFERSTORE

£744.60

Capacity: 400L Solfex SOLMB400Height: 2030mm CPS 326265Diameter: 630mm PTS SOLMB400Weight: 51 kg empty / 451 kg full TP 326265Standing losses: 3.33kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingConnections: 35mmThermostatic pockets: 2 (1x top & 1x bottom)

Page 76: Air Source Heat Pump - SOLFEX

Energy ArenaUnits 3-5Charnley Fold Industrial EstateBamber BridgePrestonLancashirePR5 6PS

Tel: 01772 312 847Fax: 01772 335 277Email: [email protected]


Recommended