Date post: | 10-Apr-2018 |
Category: |
Documents |
Upload: | prabhu-sethuraman |
View: | 226 times |
Download: | 0 times |
of 20
8/8/2019 aircosave
1/20
Conditionaire Ltd.Conditionaire Ltd.
INTRODUCING
THE AIRCONDITIONING
ENERGY SAVER
COMFORD RESOURCE
LIMITED
8/8/2019 aircosave
2/20
Conditionaire Ltd.Conditionaire Ltd.
The Aircon Energy Saver
8/8/2019 aircosave
3/20
Conditionaire Ltd.Conditionaire Ltd.
Increase Profits
=
Reduce Energy=
Save Money
8/8/2019 aircosave
4/20
Conditionaire Ltd.Conditionaire Ltd.
Specially designed for:
DX Cooling systems
Packaged systems
Fan Coil and Air Handling Units
8/8/2019 aircosave
5/20
Conditionaire Ltd.Conditionaire Ltd.
Simple Engineering
State of the art SMD technology
Plug & Play
No programming reqd
Self Learning and auto adjusting
Short installation time -typical 15mins *
Fit and forget
* Depending on site conditions
8/8/2019 aircosave
6/20
Conditionaire Ltd.Conditionaire Ltd.
How it works
1: room air (return air) is passing the fan(2) through the coil(3) and is converted intocold supply air(4)
when the Energy Saver is running it will switch off the compressor and using alllatent cooling available
when the room thermostat is satisfied the compressor will stop
1: room air (return air)
2: fan 3:coil 4: supply air
Compressor
Sens
r
8/8/2019 aircosave
7/20
Conditionaire Ltd.Conditionaire Ltd.
How it Works Temperature Graph
Unit controlled by normal thermostat
Temp C
Time (min)
Thermostat Set point - required room temperature
Temperaturecurve supply air
When thermostat requires coolingthe compressor runs and providesa constant offcoil supply
temperature
Room Temperature
8/8/2019 aircosave
8/20
Conditionaire Ltd.Conditionaire Ltd.
How it Works Energy Graph Unit controlled by normal thermostat
Time (min)
Thermostat required room temperature
Temperature ofconditioned air
ROOM TEMPERATURE
ENERGY
100%
Room Temperature
Set point
8/8/2019 aircosave
9/20
Conditionaire Ltd.Conditionaire Ltd.
How it Works Energy Graph Unit controlled by Energy Saver
Time (min)
Set point
Temperaturecurve supply air
Compressoroff Compressor off Compressor offf
ROOM TEMPERATURE
ENERGY
LATENTENERGY
100%
8/8/2019 aircosave
10/20
Conditionaire Ltd.Conditionaire Ltd.
RESULT FROMTHEHONGKONG UNIVERSITYOFSCIENCE AND TECHNOLOGY
Intake Temperature Fluctuation Curves
24
24.5
25
25.5
26
26.5
1 61 121 181 241 301 361 421 481 541 601 661 721 781 841 901 961 1021 1081 1141 1201
Data No.
Temperature
oC
Intake temp DBT without AES
Intake temp DBT with AES
8/8/2019 aircosave
11/20
Conditionaire Ltd.Conditionaire Ltd.
Simple for maintenance
Override by disconnecting the
sensor Flashing LED for control status
8/8/2019 aircosave
12/20
Conditionaire Ltd.Conditionaire Ltd.
Benefits using the AES
Saving up to 30% on your energy bill
Saving energy 24 / 7
Contributing to a healthier living environment (sick building syndrome)
Expanding the lifetime of your compressor
Helps prevent icing of compressor
Ensuring a more steady comfort temperature
Payback time can be in months*
* depending on charges and local conditions
8/8/2019 aircosave
13/20
Conditionaire Ltd.Conditionaire Ltd.
Intelligent Controlsmaking saving energy easier
8/8/2019 aircosave
14/20
Conditionaire Ltd.Conditionaire Ltd.
INSTALLATION OF AES FOR
SPLIT UNIT
8/8/2019 aircosave
15/20
Conditionaire Ltd.Conditionaire Ltd.
INSTALLATION OF THE THERMSTAT
8/8/2019 aircosave
16/20
Conditionaire Ltd.Conditionaire Ltd.
ENERGY AWARD FROM HKGCC
8/8/2019 aircosave
17/20
Conditionaire Ltd.Conditionaire Ltd.
8/8/2019 aircosave
18/20
Conditionaire Ltd.Conditionaire Ltd.
8/8/2019 aircosave
19/20
Conditionaire Ltd.Conditionaire Ltd.
8/8/2019 aircosave
20/20
Conditionaire Ltd.Conditionaire Ltd.
INSTALLATION OF THE THERMSTAT