    Conditionaire Ltd.Conditionaire Ltd.

    INTRODUCING

    THE AIRCONDITIONING

    ENERGY SAVER

    COMFORD RESOURCE

    LIMITED

  • 8/8/2019 aircosave

    2/20

    Conditionaire Ltd.Conditionaire Ltd.

    The Aircon Energy Saver

  • 8/8/2019 aircosave

    3/20

    Conditionaire Ltd.Conditionaire Ltd.

    Increase Profits

    =

    Reduce Energy=

    Save Money

  • 8/8/2019 aircosave

    4/20

    Conditionaire Ltd.Conditionaire Ltd.

    Specially designed for:

    DX Cooling systems

    Packaged systems

    Fan Coil and Air Handling Units

  • 8/8/2019 aircosave

    5/20

    Conditionaire Ltd.Conditionaire Ltd.

    Simple Engineering

    State of the art SMD technology

    Plug & Play

    No programming reqd

    Self Learning and auto adjusting

    Short installation time -typical 15mins *

    Fit and forget

    * Depending on site conditions

  • 8/8/2019 aircosave

    6/20

    Conditionaire Ltd.Conditionaire Ltd.

    How it works

    1: room air (return air) is passing the fan(2) through the coil(3) and is converted intocold supply air(4)

    when the Energy Saver is running it will switch off the compressor and using alllatent cooling available

    when the room thermostat is satisfied the compressor will stop

    1: room air (return air)

    2: fan 3:coil 4: supply air

    Compressor

    Sens

    r

  • 8/8/2019 aircosave

    7/20

    Conditionaire Ltd.Conditionaire Ltd.

    How it Works Temperature Graph

    Unit controlled by normal thermostat

    Temp C

    Time (min)

    Thermostat Set point - required room temperature

    Temperaturecurve supply air

    When thermostat requires coolingthe compressor runs and providesa constant offcoil supply

    temperature

    Room Temperature

  • 8/8/2019 aircosave

    8/20

    Conditionaire Ltd.Conditionaire Ltd.

    How it Works Energy Graph Unit controlled by normal thermostat

    Time (min)

    Thermostat required room temperature

    Temperature ofconditioned air

    ROOM TEMPERATURE

    ENERGY

    100%

    Room Temperature

    Set point

  • 8/8/2019 aircosave

    9/20

    Conditionaire Ltd.Conditionaire Ltd.

    How it Works Energy Graph Unit controlled by Energy Saver

    Time (min)

    Set point

    Temperaturecurve supply air

    Compressoroff Compressor off Compressor offf

    ROOM TEMPERATURE

    ENERGY

    LATENTENERGY

    100%

  • 8/8/2019 aircosave

    10/20

    Conditionaire Ltd.Conditionaire Ltd.

    RESULT FROMTHEHONGKONG UNIVERSITYOFSCIENCE AND TECHNOLOGY

    Intake Temperature Fluctuation Curves

    24

    24.5

    25

    25.5

    26

    26.5

    1 61 121 181 241 301 361 421 481 541 601 661 721 781 841 901 961 1021 1081 1141 1201

    Data No.

    Temperature

    oC

    Intake temp DBT without AES

    Intake temp DBT with AES

  • 8/8/2019 aircosave

    11/20

    Conditionaire Ltd.Conditionaire Ltd.

    Simple for maintenance

    Override by disconnecting the

    sensor Flashing LED for control status

  • 8/8/2019 aircosave

    12/20

    Conditionaire Ltd.Conditionaire Ltd.

    Benefits using the AES

    Saving up to 30% on your energy bill

    Saving energy 24 / 7

    Contributing to a healthier living environment (sick building syndrome)

    Expanding the lifetime of your compressor

    Helps prevent icing of compressor

    Ensuring a more steady comfort temperature

    Payback time can be in months*

    * depending on charges and local conditions

  • 8/8/2019 aircosave

    13/20

    Conditionaire Ltd.Conditionaire Ltd.

    Intelligent Controlsmaking saving energy easier

  • 8/8/2019 aircosave

    14/20

    Conditionaire Ltd.Conditionaire Ltd.

    INSTALLATION OF AES FOR

    SPLIT UNIT

  • 8/8/2019 aircosave

    15/20

    Conditionaire Ltd.Conditionaire Ltd.

    INSTALLATION OF THE THERMSTAT

  • 8/8/2019 aircosave

    16/20

    Conditionaire Ltd.Conditionaire Ltd.

    ENERGY AWARD FROM HKGCC

  • 8/8/2019 aircosave

    17/20

    Conditionaire Ltd.Conditionaire Ltd.

  • 8/8/2019 aircosave

    18/20

    Conditionaire Ltd.Conditionaire Ltd.

  • 8/8/2019 aircosave

    19/20

    Conditionaire Ltd.Conditionaire Ltd.

  • 8/8/2019 aircosave

    20/20

    Conditionaire Ltd.Conditionaire Ltd.

    INSTALLATION OF THE THERMSTAT