+ All Categories
Home > Documents > Airfel Digifix HERMETIC COMBI BOILER (ENG)

Airfel Digifix HERMETIC COMBI BOILER (ENG)

Date post: 24-Mar-2016
Category:
Upload: daikin-tuerkiye
View: 528 times
Download: 28 times
Share this document with a friend
Description:
Digifix HIGH EFFICIENCY ENERGY SAVING Environment Friendly...
4
www.airfel.com COMBI B BOILER R HIGH EFFICIENCY ENERGY SAVING Environment Friendly... HERMETIC COMBI BOILER / Digifix
Transcript
Page 1: Airfel Digifix HERMETIC COMBI BOILER (ENG)

www.airfel.com

COM

BI BBOILERR

HIGH EFFICIENCYENERGY SAVING

Environment Friendly...

HERMETIC COMBI BOILER / Digifix

Page 2: Airfel Digifix HERMETIC COMBI BOILER (ENG)

LCD DISPLAY, HIGH EFFICIENCY AND SAVING , EASY MONTAGE AND SERVICE, ELECTRIC SYSTEM PROTECTION IPx5D

• 24 kW (20.640 kcal/h) Hermetic Boiler• Control Panel with LCD display• High Efficiency 93%• Compact design, small dimensions • Electronic ignition and full modulation• Performance stars is 3 (Directive 92/42/EEC)• Suitable for Natural Gas or LPG• Heat Exchanger System made of copper• 3 level, quiet and long lasting pump• Hot instant water even with low water pressure (0.5 bar)• Electricity System Protection IPx5D• 12 Different safety systems for protection of the appliance• Automatic display of malfunctions on LCD screen• Room Thermostat (optional)• Easy installation and maintenance • Suitable for Floor Heating System

SPECIFICATIONS

DIGIFIXKB2-24CE

(Digifix Duo)

HIGH EFFICIENCY

HERMETICCOMBI

LCDDISPLAY

1.Exhaust Fume Safety FunctionExhaust fume leaving through the chimney are controlled through the Exhaust Fume Safety Thermostat. If there is any failure in the suction, the thermostat automatically shuts down the boiler and warns the user through it’s LCD and a red LED signal.

2.Anti-Block / Pump FunctionIf the boiler isn’t used for a long time the circulation pump is activated every 24 hours for five minute as to prevent blocking of the circulatory system. For this function to be enabled the boiler has to be attached to an electrical source even when it’s turned off.

3.Anti-Block / Three-way Motorised ValveEvery 24 hours the Three-way Motorised Valve rotates as to prevent blocking of the circulatory system. For this function to be enabled the boiler has to be attached to an electrical source even when it’s turned off.

4.Anti-Overheating FunctionThe in-built thermostat checks the boiler temperature constantly and in case the main tanks temperature reaches 95 °C +/-3 °C the boiler is automatically shutdown as to prevent damage to the system. A red LED and the LCD informs the user about the problem.

5.Protection against combustion without waterInbuilt sensors (0,5 mbar) detect low water pressure/water shortage and turn off the combustion as to prevent damage to the system. A red LED and the LCD informs the user about the problem.

6.Ionisation Flame Control In case there is no burner flame/ or the burner flame is extinguished the system automatically shuts down the gas flow and informs the user with a red LED and the LCD about the problem.

7. 3 Bar Safety ValfeProtects the plumbing system and the boiler from overpressure. (3 bar)

8.Automatic Air Purge Purges air pockets from the plumbing system.

9.Anti-Freeze FunctionPrevents the boiler from freezing over. NTC sensors at the heating outlet start the pump in case the water temperature falls to 7 °C and allow the heating water to circulate. If the temperature still keeps on falling to 5 °C the boiler is activated as to heat up the water until it’s 15 °C. For this function to be enabled the boiler has to be attached to an electrical and gas source even when it’s turned off.

10.Low Voltage Protection SystemLow Voltage Protection against low currents.

11.Automatic Bypass SystemEnables a shortcut of the heating water inlet and outlet as to prevent overpressure damage to the boiler.

12.Electrical Protection (IPX5D-IP44)Protects the electronic card against water and wiring.

13. Drain StopcorkAllows evacuation of the water in the plumbing system

HIGHEST SAFETY SYSTEMS

Page 3: Airfel Digifix HERMETIC COMBI BOILER (ENG)

LCD DISPLAY, DOUBLE EXCHANGER SYSTEMS, HIGH EFFICIENCY, EASY MONTAGE AND SERVICE, ENVIRONMENTALLY FRIENDLY PRODUCT, COMPACT DESIGN, ELECTRIC SYSTEM PROTECTION IPx5D

DIGIFIX DUOKM1-24CE

• 24 kW (20.640 kcal/h) Hermetic Boiler• Control Panel with LCD display• High Efficiency 93%• Compact design, small dimensions • Electronic ignition and full modulation• Performance stars is 3 (Directive 92/42/EEC)**• Performance stars is 3 for sanitary hot water (EN 13203)• Suitable for Natural Gas or LPG• Double Heat Exchanger System • Main exchanger made of copper• Stainless steel Plate Heat Exchanger• 3 level, quiet and long lasting pump• Hot instant water even with low water pressure (0.5 bar)• Electricity System Protection IPx5D• 13 Different safety system for protection of the appliance• Automatic display of malfunctions on LCD screen• Frost protection• Pump Anti Blockage System• Room Thermostat (optional)• Easy installation and maintenance • Suitable for Floor Heating System

SPECIFICATIONS

FEATURES

Manual Room Thermostat( RAA 20 )

ROOM THERMOSTAT

Digital Room Thermostat( RDE 10.1 )

HIGH EFFICIENCY

HERMETICCOMBI

LCDDISPLAY

Airfel, reserves the right to amend the specifications in the catalogue without prior notice for product improvement

DIGIFIX 24 DIGIFIX DUO 24KB2-24CE KM1-24CE

Nominal heath output max Nominal heath output min Max./min Rated Heating Capacity  (80/60°C)Max./min Rated Heating Capacity (50/30°C)Efficiency (80/60°C)Efficiency (50/30°C)Combustion Performance (Directive 92/42/EEC)NOx classFlue gas temperature max./min.System Residual HeadHeating Maximum PressureExpansion Vessel CapacityExpansion Vessel PressureMax/min Heating TemperatureSanitary Water Temperature max./min.

Quantity of Hot Water DT=25°CEfficiency Stars (EN 13203)Minimum Flow RateSanitary Circuit Pressure max./min.Supply Voltage / FrequencyTotal Absorbed Electrical PowerElectric System ProtectionNatural gas (G20) inlet pressure LPG (G30/G31) inlet pressureNatural gas (G20) consumption (max./min.)LPG (G30) consumption (max./min.)LPG (G31) consumption (max./min.)Weight (Net)Dimensions ( H x W x D )Weight (Gross)Package dimensionsMax flue gas lenght (60/100 mm)Max flue gas lenght (80/125 mm)Max flue gas lenght (80/80 mm)

kWkWkWkW%%

°Cbarbarliterbar°C°C

Liter/ min

Liter/ minBar

V/HzWIP

mbarmbarm³/hkg/hkg/h

kgmmkg

mmmmm

25,911

24,1/9,6___93,1___***

21080,5371

35/8535/55

11**2,1

10/0,5230/50

110X5D20

30/372,54 / 1,1

1,88 / 0,821,87 /0,81

34403*733*345

38470*840*420

3______

25,710,5

23,8/9,4___

92,8___***

2108,2

0,5371

35/8535/5510,2***2,1

10/0,5230/50

110X5D20

30/372,52 / 1,031,88 / 0,811,87 / 0,80

35403*730*345

39470*840*420

3______

Ener

gyP

erfo

rman

ceH

eati

ng

Circ

uit

Elec

tric

Dat

aSa

nita

ry

Wat

er C

ircu

itEm

mis

sion

sD

imen

sion

s

UnitSpecifications

Page 4: Airfel Digifix HERMETIC COMBI BOILER (ENG)

HERMETIC COMBI BOILER / Digifix

Distributed by:

HIGH EFFICIENCYENERGY SAVING

Enviromental Friendly...

DAIKIN TURKEY Hürriyet Mah. E-5 Yan yol Üzeri no:57/2 Kartal / ISTANBUL/ TURKEYTel:(+90 216) 453 27 00 Pbx Fax: (+90 216) 671 06 19 [email protected]

www.daikin.com.tr • www.airfel.com


Recommended