Nokia Siemens Networks WCDMA RAN, Rel. RU10, System Library, v. 5 RNC Base Station Alarms (7000-7900) DN99580892 Issue 07E Approval Date 2009/12/18
Transcript
  • Nokia Siemens Networks WCDMA RAN, Rel. RU10, System Library, v. 5

    RNC Base Station Alarms (7000-7900)

    DN99580892

    Issue 07EApproval Date 2009/12/18

  • 2 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806aca96

    The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.

    The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.

    Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.

    This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.

    The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

    Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.

    Copyright Nokia Siemens Networks 2010. All rights reserved

    f Important Notice on Product Safety Elevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts may also have elevated operating temperatures.

    Non-observance of these conditions and the safety instructions can result in personal injury or in property damage.

    Therefore, only trained and qualified personnel may install and maintain the system.

    The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to comply with the applicable safety standards.

    The same text in German:

    Wichtiger Hinweis zur Produktsicherheit

    In elektrischen Anlagen stehen zwangslufig bestimmte Teile der Gerte unter Span-nung. Einige Teile knnen auch eine hohe Betriebstemperatur aufweisen.

    Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Krperverlet-zungen und Sachschden fhren.

    Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und wartet.

    Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Gerte mssen die zutreffenden Sicherheitsbestimmungen erfllen.

  • DN99580892Issue 07E

    3

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806aca96

    Table of ContentsThis document has 224 pages.

    Summary of Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

    1 Default alarm indication preventions in the system . . . . . . . . . . . . . . . . . 6

    2 List of Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    3 7401 EXTERNAL AL 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

    4 7402 EXTERNAL AL 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    5 7403 EXTERNAL AL 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    6 7404 EXTERNAL AL 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    7 7405 EXTERNAL AL 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

    8 7406 EXTERNAL AL 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

    9 7407 EXTERNAL AL 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    10 7408 EXTERNAL AL 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

    11 7409 EXTERNAL AL 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

    12 7410 EXTERNAL AL 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

    13 7411 EXTERNAL AL 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

    14 7412 EXTERNAL AL 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

    15 7413 EXTERNAL AL 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

    16 7414 EXTERNAL AL 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

    17 7415 EXTERNAL AL 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

    18 7416 EXTERNAL AL 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

    19 7417 EXTERNAL AL 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    20 7418 EXTERNAL AL 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

    21 7419 EXTERNAL AL 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

    22 7420 EXTERNAL AL 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

    23 7421 EXTERNAL AL 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

    24 7422 EXTERNAL AL 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

    25 7423 EXTERNAL AL 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

    26 7424 EXTERNAL AL 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

    27 7425 EXTERNAL AL 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

    28 7650 BASE STATION FAULTY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

    29 7651 BASE STATION OPERATION DEGRADED . . . . . . . . . . . . . . . . 58

    30 7652 BASE STATION NOTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . 96

  • 4 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806aca96

    31 7653 CELL FAULTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117

    32 7654 CELL OPERATION DEGRADED . . . . . . . . . . . . . . . . . . . . . . . . 138

    33 7655 CELL NOTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159

    34 7660 BASE STATION LICENCE EXPIRED . . . . . . . . . . . . . . . . . . . . . 165

    35 7661 BASE STATION LICENCE NOTIFICATION . . . . . . . . . . . . . . . . 166

    36 7665 BASE STATION TRANSMISSION ALARM . . . . . . . . . . . . . . . . . 168

    37 7740 BEATING WCDMA BTS ALARM. . . . . . . . . . . . . . . . . . . . . . . . . 182

    38 7750 FAILURE IN WCDMA WBTS O&M CONNECTION . . . . . . . . . . 183

    39 7761 RNW O&M SCENARIO FAILURE . . . . . . . . . . . . . . . . . . . . . . . . 188

    40 7762 RNW DATABASE OPERATION FAILURE . . . . . . . . . . . . . . . . . 193

    41 7771 WCDMA CELL OUT OF USE . . . . . . . . . . . . . . . . . . . . . . . . . . . 196

    42 7772 HSDPA CONFIGURATION FAILED . . . . . . . . . . . . . . . . . . . . . . 199

    43 7775 INCONSISTENCY IN WCEL CONFIGURATION PARAMETERS . .203

    44 7776 HSDPA FAILURE IN WCEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205

    45 7778 WCDMA BTS DEDICATED MEASUREMENT FAILURE . . . . . . 207

    46 7779 RECOVERY ACTIONS ONGOING . . . . . . . . . . . . . . . . . . . . . . . 209

    47 7780 HSUPA FAILURE IN WCEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211

    48 7781 NETWORK ELEMENT CONFIGURATION ERROR . . . . . . . . . . 213

    49 7782 HSUPA CONFIGURATION FAILED . . . . . . . . . . . . . . . . . . . . . . 215

    50 7783 IP BASED D-NBAP LINK FAILURE. . . . . . . . . . . . . . . . . . . . . . . 220

    51 7784 RECOVERY ACTION FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . 221

    52 7799 RNC RADIO NETWORK TEST ALARM . . . . . . . . . . . . . . . . . . . 224

  • DN99580892Issue 07E

    5

    RNC Base Station Alarms (7000-7900) Summary of Changes

    Id:0900d805806acaaf

    Summary of ChangesChanges between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues.

    Changes made between issues 07D and 07E

    Modified alarms

    Note that the issue numbering system is changing. For more information, see Guide to WCDMA RAN Documentation.

    Changes made between issues 7-3 and 07D

    Modified alarms

    Changes made between issues 7-2 and 7-3

    Modified alarms

    7650 7652 7654 7665

    7651 7653 7655

    7784

    7776 7780

  • 6 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    Default alarm indication preventions in the system

    1 Default alarm indication preventions in the systemAlarm indication preventions for certain alarms have been set by default in RNC. This has been done to reduce the amount of alarm indications that RNC reports to NetAct. The list of alarms below shows the affected alarms that are indication-prevented by default in RNC.

    The alarm 7775 is indication prevented in RNC because alarm 3325 informs about WCEL parameter inconsistencies in RNC level. For more information, see the instruc-tions given for alarm 7775 and 3325. Alarm 7799 is an old test alarm for RNC testing purposes which is not set by RNC in any situation anymore.

    Base Station Alarms

    7775 INCONSISTENCY IN WCEL CONFIGURATION PARAMETERS 7799 RNC RADIO NETWORK TEST ALARM

  • DN99580892Issue 07E

    7

    RNC Base Station Alarms (7000-7900) List of Alarms

    Id:0900d805806acaaf

    2 List of Alarms7401 EXTERNAL AL 1

    7402 EXTERNAL AL 2

    7403 EXTERNAL AL 3

    7404 EXTERNAL AL 4

    7405 EXTERNAL AL 5

    7406 EXTERNAL AL 6

    7407 EXTERNAL AL 7

    7408 EXTERNAL AL 8

    7409 EXTERNAL AL 9

    7410 EXTERNAL AL 10

    7411 EXTERNAL AL 11

    7412 EXTERNAL AL 12

    7413 EXTERNAL AL 13

    7414 EXTERNAL AL 14

    7415 EXTERNAL AL 15

    7416 EXTERNAL AL 16

    7417 EXTERNAL AL 17

    7418 EXTERNAL AL 18

    7419 EXTERNAL AL 19

    7420 EXTERNAL AL 20

    7421 EXTERNAL AL 21

    7422 EXTERNAL AL 22

    7423 EXTERNAL AL 23

    7424 EXTERNAL AL 24

    7425 EXTERNAL AL 25

    7650 BASE STATION FAULTY

    7651 BASE STATION OPERATION DEGRADED

    7652 BASE STATION NOTIFICATION

    7653 CELL FAULTY

    7654 CELL OPERATION DEGRADED

    7655 CELL NOTIFICATION

    7660 BASE STATION LICENCE EXPIRED

    7661 BASE STATION LICENCE NOTIFICATION

    7665 BASE STATION TRANSMISSION ALARM

    7740 BEATING WCDMA BTS ALARM

    7750 FAILURE IN WCDMA WBTS O&M CONNECTION

    7761 RNW O&M SCENARIO FAILURE

  • 8 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    List of Alarms

    7762 RNW DATABASE OPERATION FAILURE

    7771 WCDMA CELL OUT OF USE

    7772 HSDPA CONFIGURATION FAILED

    7775 INCONSISTENCY IN WCEL CONFIGURATION PARAMETERS

    7776 HSDPA FAILURE IN WCEL

    7778 WCDMA BTS DEDICATED MEASUREMENT FAILURE

    7779 RECOVERY ACTIONS ONGOING

    7780 HSUPA FAILURE IN WCEL

    7781 NETWORK ELEMENT CONFIGURATION ERROR

    7782 HSUPA CONFIGURATION FAILED

    7783 IP BASED D-NBAP LINK FAILURE

    7784 RECOVERY ACTION FAILURE

    7799 RNC RADIO NETWORK TEST ALARM

    Alarm parametersThe following parameter settings are the default settings. The operator can modify them with an MML command.

    The following listing also contains alarm event types. Please note that this information is not part of the alarm parameter listing and it is not possible to change those values using MML commands. The information here is for documentation purposes only.

    NR TEXT CLS OUT SDC SDD CDL LVT--------------------------------------------------------------------------------

    7401 EXTERNAL AL 1 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7402 EXTERNAL AL 2 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7403 EXTERNAL AL 3 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7404 EXTERNAL AL 4 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7405 EXTERNAL AL 5 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7406 EXTERNAL AL 6 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

  • DN99580892Issue 07E

    9

    RNC Base Station Alarms (7000-7900) List of Alarms

    Id:0900d805806acaaf

    7407 EXTERNAL AL 7 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7408 EXTERNAL AL 8 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7409 EXTERNAL AL 9 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7410 EXTERNAL AL 10 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7411 EXTERNAL AL 11 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7412 EXTERNAL AL 12 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7413 EXTERNAL AL 13 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7414 EXTERNAL AL 14 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7415 EXTERNAL AL 15 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7416 EXTERNAL AL 16 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7417 EXTERNAL AL 17 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7418 EXTERNAL AL 18 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7419 EXTERNAL AL 19 * NONE 00:10 - 00:10 -

  • 10 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    List of Alarms

    EVENT TYPE: ENVIRONMENTAL

    7420 EXTERNAL AL 20 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7421 EXTERNAL AL 21 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7422 EXTERNAL AL 22 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7423 EXTERNAL AL 23 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7424 EXTERNAL AL 24 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7425 EXTERNAL AL 25 * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

    7650 BASE STATION FAULTY *** 3 00:10 - 00:10 - EVENT TYPE: QUALITY OF SERVICE

    7651 BASE STATION OPERATION DEGRADED ** 5 00:10 - 00:10 - EVENT TYPE: QUALITY OF SERVICE

    7652 BASE STATION NOTIFICATION * NONE 00:10 - 00:10 - EVENT TYPE: QUALITY OF SERVICE

    7653 CELL FAULTY *** 3 00:10 - 00:10 - EVENT TYPE: QUALITY OF SERVICE

    7654 CELL OPERATION DEGRADED ** 5 00:10 - 00:10 - EVENT TYPE: QUALITY OF SERVICE

    7655 CELL NOTIFICATION * NONE 00:10 - 00:10 - EVENT TYPE: QUALITY OF SERVICE

    7660 BASE STATION LICENCE EXPIRED *** 3

  • DN99580892Issue 07E

    11

    RNC Base Station Alarms (7000-7900) List of Alarms

    Id:0900d805806acaaf

    00:10 - 00:10 - EVENT TYPE: QUALITY OF SERVICE

    7661 BASE STATION LICENCE NOTIFICATION * NONE 00:10 - 00:10 - EVENT TYPE: QUALITY OF SERVICE

    7665 BASE STATION TRANSMISSION ALARM * NONE 00:10 - 00:10 - EVENT TYPE: QUALITY OF SERVICE

    7740 BEATING WCDMA BTS ALARM ** 5 00:00 - 00:00 - EVENT TYPE: PROCESSING ERROR

    7750 FAILURE IN WCDMA WBTS O&M CONNECTION * NONE 00:10 - 00:10 - EVENT TYPE: COMMUNICATIONS

    7761 RNW O&M SCENARIO FAILURE ** 5 00:40 - 00:00 - EVENT TYPE: QUALITY OF SERVICE

    7762 RNW DATABASE OPERATION FAILURE ** 5 00:05 - 00:00 - EVENT TYPE: PROCESSING ERROR

    7771 WCDMA CELL OUT OF USE ** 5 02:00 - 00:20 - EVENT TYPE: QUALITY OF SERVICE

    7772 HSDPA CONFIGURATION FAILED ** 5 00:05 - 00:05 - EVENT TYPE: QUALITY OF SERVICE

    7775 INCONSISTENCY IN WCEL CONFIGURATION PARAMETERS * NONE 00:00 - 00:00 - EVENT TYPE: PROCESSING ERROR

    7776 HSDPA FAILURE IN WCEL ** 5 00:05 - 00:00 - EVENT TYPE: QUALITY OF SERVICE

    7778 WCDMA BTS DEDICATED MEASUREMENT FAILURE ** 5 00:00 - 00:00 - EVENT TYPE: QUALITY OF SERVICE

    7779 RECOVERY ACTIONS ONGOING * NONE 00:00 - 00:00 - EVENT TYPE: QUALITY OF SERVICE

  • 12 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    List of Alarms

    7780 HSUPA FAILURE IN WCEL ** 5 00:05 - 00:00 - EVENT TYPE: QUALITY OF SERVICE

    7781 NETWORK ELEMENT CONFIGURATION ERROR *** 2 00:00 - 00:00 - EVENT TYPE: PROCESSING ERROR

    7782 HSUPA CONFIGURATION FAILED ** 5 00:05 - 00:05 - EVENT TYPE: QUALITY OF SERVICE

    7783 IP BASED D-NBAP LINK FAILURE ** 5 00:30 - 00:30 - EVENT TYPE: COMMUNICATIONS

    7784 RECOVERY ACTION FAILURE ** 5 00:00 - 00:00 - EVENT TYPE: COMMUNICATIONS

    7799 RNC RADIO NETWORK TEST ALARM * NONE 00:10 - 00:10 - EVENT TYPE: ENVIRONMENTAL

  • DN99580892Issue 07E

    13

    RNC Base Station Alarms (7000-7900) 7401 EXTERNAL AL 1

    Id:0900d805806acaaf

    3 7401 EXTERNAL AL 1Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in an HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 1.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • 14 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7402 EXTERNAL AL 2

    4 7402 EXTERNAL AL 2Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 2.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • DN99580892Issue 07E

    15

    RNC Base Station Alarms (7000-7900) 7403 EXTERNAL AL 3

    Id:0900d805806acaaf

    5 7403 EXTERNAL AL 3Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 3.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • 16 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7404 EXTERNAL AL 4

    6 7404 EXTERNAL AL 4Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 4.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • DN99580892Issue 07E

    17

    RNC Base Station Alarms (7000-7900) 7405 EXTERNAL AL 5

    Id:0900d805806acaaf

    7 7405 EXTERNAL AL 5Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 5.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • 18 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7406 EXTERNAL AL 6

    8 7406 EXTERNAL AL 6Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 6.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • DN99580892Issue 07E

    19

    RNC Base Station Alarms (7000-7900) 7407 EXTERNAL AL 7

    Id:0900d805806acaaf

    9 7407 EXTERNAL AL 7Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 7.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • 20 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7408 EXTERNAL AL 8

    10 7408 EXTERNAL AL 8Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 8.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • DN99580892Issue 07E

    21

    RNC Base Station Alarms (7000-7900) 7409 EXTERNAL AL 9

    Id:0900d805806acaaf

    11 7409 EXTERNAL AL 9Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 9.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • 22 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7410 EXTERNAL AL 10

    12 7410 EXTERNAL AL 10Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 10.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • DN99580892Issue 07E

    23

    RNC Base Station Alarms (7000-7900) 7411 EXTERNAL AL 11

    Id:0900d805806acaaf

    13 7411 EXTERNAL AL 11Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 11.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • 24 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7412 EXTERNAL AL 12

    14 7412 EXTERNAL AL 12Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 12.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • DN99580892Issue 07E

    25

    RNC Base Station Alarms (7000-7900) 7413 EXTERNAL AL 13

    Id:0900d805806acaaf

    15 7413 EXTERNAL AL 13Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 13.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • 26 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7414 EXTERNAL AL 14

    16 7414 EXTERNAL AL 14Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 14.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • DN99580892Issue 07E

    27

    RNC Base Station Alarms (7000-7900) 7415 EXTERNAL AL 15

    Id:0900d805806acaaf

    17 7415 EXTERNAL AL 15Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 15.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • 28 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7416 EXTERNAL AL 16

    18 7416 EXTERNAL AL 16Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 16.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • DN99580892Issue 07E

    29

    RNC Base Station Alarms (7000-7900) 7417 EXTERNAL AL 17

    Id:0900d805806acaaf

    19 7417 EXTERNAL AL 17Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 17.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • 30 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7418 EXTERNAL AL 18

    20 7418 EXTERNAL AL 18Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 18.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • DN99580892Issue 07E

    31

    RNC Base Station Alarms (7000-7900) 7419 EXTERNAL AL 19

    Id:0900d805806acaaf

    21 7419 EXTERNAL AL 19Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 19.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • 32 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7420 EXTERNAL AL 20

    22 7420 EXTERNAL AL 20Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 20.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • DN99580892Issue 07E

    33

    RNC Base Station Alarms (7000-7900) 7421 EXTERNAL AL 21

    Id:0900d805806acaaf

    23 7421 EXTERNAL AL 21Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 21.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • 34 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7422 EXTERNAL AL 22

    24 7422 EXTERNAL AL 22Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 22.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • DN99580892Issue 07E

    35

    RNC Base Station Alarms (7000-7900) 7423 EXTERNAL AL 23

    Id:0900d805806acaaf

    25 7423 EXTERNAL AL 23Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 23.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • 36 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7424 EXTERNAL AL 24

    26 7424 EXTERNAL AL 24Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 24.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • DN99580892Issue 07E

    37

    RNC Base Station Alarms (7000-7900) 7425 EXTERNAL AL 25

    Id:0900d805806acaaf

    27 7425 EXTERNAL AL 25Meaning

    This is an external user-defined alarm. The alarm is defined bythe user in a HW database.

    Supplementary information fields

    InstructionsThe operation depends on what kind of alarm is used as externalalarm no. 25.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • 38 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7650 BASE STATION FAULTY

    28 7650 BASE STATION FAULTYMeaning

    A critical fault (or faults) has occurred in the base station.

    Check the reason for the fault from the supplementary text field ofthe alarm.

    The effect of the fault on the functioning of the network elementdepends on the fault description. For more information, see basestation fault descriptions in WCDMA RAN and I-HSPA System Libraries.

    Supplementary information fields1 rack (cabinet) number

    2 shelf number

    3 slot

    4 type of unit

    5 unit number

    6 subunit number

    For more information, see instructions on Alarm Structure.

    InstructionsVerify the configuration of a BTS by checking the commissioning, cablingand correct installation of the units/modules at the BTS. Make sure theenvironment does not cause the fault.

    Before a unit/module is replaced at the BTS, the site should be reset torecover from any temporary faults which might have caused themalfunctioning of the unit/module. When an active alarm is a 'Start'alarm, a site reset is required to cancel the alarm. If the site reset ormodule block/unblock does not help, replace the faulty unit/module (seethe source of the alarm and instructions fields of the correspondingalarms).

    Below is the list of BTS fault(s) which may have caused this alarm inBTS WN5.0 release. In case of earlier SW release and in case you needmore detailed fault descriptions refer to WCDMA RAN and I-HSPA SystemLibraries. The BTS fault descriptions are also included in BTS SW releasedocumentation. If that does not help, contact your local Nokia SiemensNetworks representative.

  • DN99580892Issue 07E

    39

    RNC Base Station Alarms (7000-7900) 7650 BASE STATION FAULTY

    Id:0900d805806acaaf

    FAULT NAME : ATM faultyMEANING : A WAM internal failure.INSTRUCTIONS : 1. If ping to the BTS is working, restart the BTS remotely.

    2. Ping the BTS. If it is not working but ping to the AXC is working, then restart the AXC remotely so that the BTS is also restarted automatically.

    3. Ping the AXC. If it is not working, visit the site and restart the BTS. If this does not help, replace the alarming WAM unit.

    FAULT NAME : ATM processor faultyMEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode:

    There is a fault in the WAM processor SFN interrupt or the SFN is not being updated in the WSPC MCU.

    There is a MCU failure in the WAM or the ATM loop test at start-up has failed.

    FlexiBTS:

    There is such a fault in the FSM that the SFN is not being updated in the FSP MCU.INSTRUCTIONS : UltraSite, MetroSite, MetroSite 50, Triple-mode:

    1. If ping to the BTS is working, restart the BTS remotely.

    2. Ping the BTS. If it is not working but ping to the AXC is working, restart the AXC remotely so that the BTS is also automatically restarted.

    3. Ping the AXC. If it is not working, visit the site and restart the BTS. If this does not help, replace the alarming WAM unit.

    FlexiBTS:

    1. Reset the BTS.

    2. If the BTS reset does not help, change the alarming module.

    FAULT NAME : Antenna link is downMEANING : Antenna (RP3) link is down: transmitter or receiver drops from synchronization.INSTRUCTIONS : 1. If the alarming module is the Extension System Module (FSM2), restart it. If the alarming module is the System Module (FSM1), restart BTS.

  • 40 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7650 BASE STATION FAULTY

    2. If that does not help, replace the alarming FSM.

    FAULT NAME : BB bus message collision errorMEANING : Routed RF baseband bus messages have collided and the data in the output baseband internal link is lost because the baseband bus is incorrectly configured.INSTRUCTIONS : 1. Check antenna mapping to the local cells in the commissioning file.

    2. Check the cables between the System Module and RF Module.

    3. Replace the alarming module.

    FAULT NAME : BB bus reception errorMEANING : The master frame in the received RF BB frame is not in the correct place related to the internally generated master frame pulse. Either the frame has been set into the wrong place (PI delay) or the data itself is in the wrong place.INSTRUCTIONS : 1. If only one FSP in the BTS generates this alarm, the FSP is faulty.

    2. If all FSPs generate this alarm, the FSM is faulty.

    3. Block/unblock the FSM.

    4. If that does not help, replace the faulty module (System Module).

    FAULT NAME : BB bus reception error (summing device)MEANING : The master frame in the received baseband bus frame is not in the correct place related to the internally generated master frame pulse. Either the frame has been set into the wrong place (PI delay) or the data itself is in the wrong place.INSTRUCTIONS : 1. Check the cables between the System Module and the RF Module.

    2. Replace the unit that causes the alarm (System Module).

    FAULT NAME : BB bus transmission errorMEANING : A decoding error has been detected in the baseband internal link. The data packet is lost or the content is corrupted.

    This situation is also triggered when the links do not synchronize with each other.INSTRUCTIONS : 1. Check the cables between the Master System Module and RF Module/Extension System Module.

    2. Replace the alarming unit (System Module).

    FAULT NAME : BTS BlockedMEANING : The BTS is blocked with BTS Site Manager. The meaning of the

  • DN99580892Issue 07E

    41

    RNC Base Station Alarms (7000-7900) 7650 BASE STATION FAULTY

    Id:0900d805806acaaf

    fault is to avoid alarms that may be raised during a BTS maintenance task.INSTRUCTIONS : To cancel the alarm, unblock the BTS. Unblocking the BTS causes a site reset.

    FAULT NAME : BTS config error (WSMA and WSMB can not coexist)MEANING : WSMA and WSMB units are detected in the same cabinet. They cannot coexist in the BTS.INSTRUCTIONS : Replace the conflicting unit WSMA with the WSMB, or vice versa.

    FAULT NAME : BTS file errorMEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode: The BTS unit properties data is invalid or missing.

    FlexiBTS: The BTS module properties data or optical interface FPGA file is invalid or missing. The FSP MCU SW file is invalid or missing.INSTRUCTIONS : UltraSite, MetroSite, MetroSite 50, Triple-mode:

    1. Download two different SW packages so that the faulty file is removed from the BTS.

    2. Download the SW again.

    3. If the fault still exists after 10 minutes, replace the alarming unit.

    FlexiBTS:

    1. Download two different SW packages so that the faulty file is removed from the BTS.

    2. Download the SW again.

    3. Replace the System Module.

    FAULT NAME : BTS file errorMEANING : Telecom configuration file(s) are invalid or missing.INSTRUCTIONS : UltraSite, MetroSite, MetroSite 50, Triple-mode:

    1. Download two different SW packages so that the faulty file is removed from the BTS.

    2. Download the SW again.

    3. If the fault still exists after 10 minutes, replace the alarming unit.

    FlexiBTS:

  • 42 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7650 BASE STATION FAULTY

    1. Download two different SW packages so that the faulty file is removed from the BTS.

    2. Download the SW again.

    3. Replace the System Module.

    FAULT NAME : BTS internal SW management problemMEANING : A software update to a module or subassembly has failed, or a corrupted SW file has been detected in the FLASH.INSTRUCTIONS : Note! Perform the steps below in the listed order until the alarm disappears.

    1. Check the other active alarms. If the ROM disk is corrupted, change the alarming module.

    2. Reset the RF Module and/or System Module, depending on the alarm source: a. Reset the RF Module by blocking/unblocking it. b. Reset the System Module.

    3. Update and activate the SW to the BTS.

    4. Check the SW files.

    5. Replace the alarming module.

    FAULT NAME : Baseband Bus failureMEANING : The FlexiBTS has detected an abnormal operation or a failure in the BTS internal baseband bus. The failure cannot be pointed to a specific module but there are several possible fault sources.INSTRUCTIONS : Note! Perform the steps below in the listed order until the alarm disappears.

    1. Check the other active BTS alarms and act accordingly.

    2. Check the cables between the System Module and RF Module/Extension System Module.

    3. Reset the RF Module and/or System Module, depending on the alarm source: a. Reset the RF Module by blocking/unblocking it. b. Reset the Extension System Module by blocking/unblocking it. c. Reset the master System Module.

    4. Replace the alarming RF Module/Extension System Module.

  • DN99580892Issue 07E

    43

    RNC Base Station Alarms (7000-7900) 7650 BASE STATION FAULTY

    Id:0900d805806acaaf

    5. If the master System Module is the source or replacing the RF Module/Extension System Module does not clear the fault situation, replace the alarming master System Module.

    FAULT NAME : Baseband bus configuration of was rejectedMEANING : The baseband bus related configuration of was rejected by the HW SW, DSP or LTX.INSTRUCTIONS : Replace the alarming module.

    FAULT NAME : Baseband reference clock missing (WCI)MEANING : The WCI does not deliver the Baseband Reference Clock (BRCLK) for the relevant units, because either the transceiver circuit in the WSC or the bus is faulty, or the WSC does not distribute the clock source.INSTRUCTIONS : You have two alternative procedures:

    1. If there is only one clock unit in the cabinet, replace the WSC.

    2. If Step 1 does not help, replace the WCI.

    OR

    1. If there are two clock units in the cabinet, replace the WCI.

    2. If Step 1 does not help, replace both WSC units.

    FAULT NAME : Baseband reference clock missing (WSC)MEANING : The WSC is not able to deliver the clock signals required by the other units.INSTRUCTIONS : Replace the WSC.

    FAULT NAME : Commissioning error: MEANING : Some of the commissioning parameters are either missing or faulty, or there is a mismatch between them.INSTRUCTIONS : Note! Perform the steps below in the listed order until the alarm disappears.

    1. Check the commissioning parameters with the BTS Site Manager Commissioning Wizard.

    2. Load the correct commissioning file to the BTS.

    FAULT NAME : Communication failureMEANING : Communication with the application failed. It has not replied to the message that has been sent/resent to it.

    FSPB/Faraday: Faraday has not sent a specific mandatory indication message in the start-up during the time limit the message is expected to arrive.

  • 44 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7650 BASE STATION FAULTY

    INSTRUCTIONS : 1. Check that the unit/module is properly connected. If the unit/module led does not light up, the unit/module is faulty. Check the alarming unit/module.

    2. Check the alarm history.

    FAULT NAME : Communication failureMEANING : An internal communication fault in the decoding process in the module, for example, a decode co-prosessor error.INSTRUCTIONS : 1. Reset the alarming unit/module.

    2. Replace the alarming unit/module.

    FAULT NAME : Communication failure inside WSPMEANING : An internal communication failure between the DSP processors.INSTRUCTIONS : UltraSite, MetroSite, MetroSite 50, Triple-mode:

    1. Block the alarming WSP.

    2. The fault might be in the WTR or WPA (see Troubleshooting instructions).

    Otherwise, check for other alarms. If the " autonomous reset as recovery action" alarm has occurred for the alarming WSP, replace the alarming WSP unit.

    FlexiBTS:

    1. If only one FSP in BTS generates this alarm, the FSP is faulty.

    2. If all FSPs generate this alarm, the FSM is faulty.

    3. Block/unblock the FSM.

    4. If that does not help, replace the faulty module (System Module).

    FAULT NAME : Configuration error: MEANING : There is a compatibility problem in the BTS HW/SW versions or the HW/HW configuration. Another possibility is that there is a mismatch between the BTS configuration and the RNC/I-HSPA adapter parameters.INSTRUCTIONS : Note! Perform the steps below in the listed order until the alarm disappears.

    1. Check the installed HW/SW version compatibility and the HW compatibility with the current BTS configuration.

    2. Check that the BTS cell parameters from the RNC/I-HSPA adapter match the BTS HW configuration (for example frequency,

  • DN99580892Issue 07E

    45

    RNC Base Station Alarms (7000-7900) 7650 BASE STATION FAULTY

    Id:0900d805806acaaf

    power).

    3. Check the RNC/I-HSPA adapter alarms for the alarming local cell (LCR).

    4. Recommission the BTS to ensure that all parameters are correctly configured.

    FAULT NAME : Connection to transmission brokenMEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode:

    The AXC is missing, data or states are corrupted in the ATM, or there are possible hardware or transmission related failures.

    FlexiBTS:

    Data or states are corrupted in the ATM, or there are possible hardware or transmission related failures.INSTRUCTIONS : UltraSite, MetroSite, MetroSite 50, Triple-mode:

    1. Check the transmission connections.

    2. If the transmission type is the AXC, reset the WAM.

    3. If that does not help, replace the alarming unit.

    FlexiBTS:

    1. Check the transmission connections.

    2. Reset the site.

    3. If that does not help, replace the alarming System Module.

    FAULT NAME : DSC-bus failureMEANING : There is a failure in the bus between the WAM and WSP (DSC-bus), which means that messages do not get through via that DSC-bus.INSTRUCTIONS : 1. Block/unblock the alarming unit.

    2. Replace the alarming unit.

    FAULT NAME : DSC-bus failureMEANING : There are communication problems between the WAM and WSP. This alarm may occur if the WSP is hot removed or the WSP crashes.INSTRUCTIONS : If the failure still exists after the site reset, replace the WAM unit.

    FAULT NAME : DSP failure in radiolink creationMEANING : Radio link creation has failed repeatedly because of DSP

  • 46 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7650 BASE STATION FAULTY

    rejection.INSTRUCTIONS : UltraSite, MetroSite, MetroSite 50, Triple-mode:

    1. Block/unblock the alarming unit.

    2. Replace the alarming unit.

    FlexiBTS:

    If the faulty FSP is in the extension module, block/unblock the extension module, otherwise block/unblock the BTS.

    FAULT NAME : Downlink data buffer synchronization failureMEANING : The downlink data buffer has lost synchronization.INSTRUCTIONS : 1. If only one FSP in the BTS generates this alarm, the FSP is faulty.

    2. If all FSPs generate this alarm, the FSM is faulty.

    3. Block/unblock the FSM.

    4. If that does not help, replace the faulty module (System Module).

    FAULT NAME : FSP Frame synchronisation failedMEANING : The frame synchronization burst, SFN or SFCLK signal from the FCM is missing.INSTRUCTIONS : 1. Reset the site.

    2. If that does not help, replace the System Module.

    FAULT NAME : Failure in optical RP3 interfaceMEANING : The FlexiBTS has detected an abnormal operation or a failure in an optical RP3 interface between two modules. The failure cannot be pointed to a specific module but there are several possible fault sources.INSTRUCTIONS : Note! Perform the steps below in the listed order until the alarm disappears.

    1. Check the other active BTS alarms and act accordingly.

    2. Check the cables between the System Module and RF Module/Extension System Module. Note that dirty optical connectors may cause the signal level to drop too low.

    3. Depending on the alarm source, reset the RF Module, Extension System Module and/or System Module by blocking/unblocking it.

    4. Replace the alarming module's Small Form Factor Pluggable (SFP). Check also the SFP in the other end and replace it, if

  • DN99580892Issue 07E

    47

    RNC Base Station Alarms (7000-7900) 7650 BASE STATION FAULTY

    Id:0900d805806acaaf

    needed.

    5. Replace the alarming RF Module/Extension System Module.

    6. If the System Module is the only alarming source or replacing the RF Module/Extension System Module does not clear the fault situation, replace the alarming System Module.

    FAULT NAME : Fatal OSE ErrorMEANING : The Operating System Embedded (OSE) goes into the error handler with a fatal status. The cause can be, for example, out of memory situation.

    If only one FSP in BTS generates this fault, there is a malfunction in one of the FSP submodules. If all the FSPs generate this fault, there is a malfunction in the FSM.INSTRUCTIONS : FlexiBTS:

    Note! Perform the steps below in the listed order until the fault disappears.

    1. Reset the System Module.

    2. Replace the System Module.

    FAULT NAME : Fault between WAM and WSP SFN (WSP)MEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode: Synchronization between the WAM and WSP is lost.

    FlexiBTS: Synchronization between the FCM and FSP is lost.INSTRUCTIONS : UltraSite, MetroSite, MetroSite 50, Triple-mode:

    1. If only one WSP in the cabinet generates this alarm, the WSP is faulty.

    2. If all WSPs in a subrack generate this alarm, the WAM is faulty.

    3. If all WSPs generate this alarm, the WSC/WMC is faulty.

    Otherwise, check for other alarms. If the " autonomous reset as a recovery action" alarm has occurred for the faulty WSP, replace the faulty WSP unit.

    FlexiBTS:

    1. If only one FSP in BTS generates this alarm, the FSP is faulty.

    2. If all FSPs generate this alarm, the FSM is faulty.

  • 48 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7650 BASE STATION FAULTY

    3. Block/unblock the FSM.

    4. If that does not help, replace the faulty module (System Module).

    FAULT NAME : Fault in ATM interfaceMEANING : The WAM ATM interface is not responding correctly.INSTRUCTIONS : 1. Block/unblock the alarming unit. This resets the BTS.

    2. If that does not help, replace the alarming unit.

    FAULT NAME : Fault in ATM interfaceMEANING : WAM ATM interface, AXC or CIF bus failure. The AXC may have been reset.

    WAM processor failure.INSTRUCTIONS : 1. Block/unblock the alarming unit. This will reset the BTS.

    2. Swap the WAM units between subracks and check if the alarm follows the unit. Replace the alarming WAM unit.

    3. Check the AXU.

    4. Check the backplane connection between the WAM and AXU.

    FAULT NAME : Fault in O&M and DSP SW interfaceMEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode: Communication failure between the WAM and DSP.

    FlexiBTS: Communication failure between the FCM and FSP.INSTRUCTIONS : UltraSite, MetroSite, MetroSite 50, Triple-mode:

    1. Block/unblock the alarming unit.

    2. Replace the alarming unit.

    FlexiBTS:

    1. Block/unblock the alarming unit.

    2. Replace the System Module.

    FAULT NAME : Frame Synchronization failureMEANING : The frame clock receiver has lost its synchronization. The FSM internal frame clock is not synchronized with the FSM 100 Hz frame clock.INSTRUCTIONS : 1. If only one FSP in the BTS generates this alarm, the FSP is faulty.

    2. If all FSPs generate this alarm, the FSM is faulty.

  • DN99580892Issue 07E

    49

    RNC Base Station Alarms (7000-7900) 7650 BASE STATION FAULTY

    Id:0900d805806acaaf

    3. Block/unblock the FSM.

    4. If that does not help, replace the faulty module (System Module).

    FAULT NAME : Frame clock deviation faultMEANING : Synchronization to the clock control unit frame pulse has been achieved earlier but it differs from the currently received frame pulse. The internally generated frame clock may have drifted.INSTRUCTIONS : 1. Check the cables between the System Module and RF Module/Extension System Module.

    2. Reset the alarming System Module.

    3. Replace the alarming System Module.

    FAULT NAME : Frame number synchronisation error in optical interfaceMEANING : The timing of the new RP1 synchronization burst deviates from the present RP1 timing maintained in the BTS.INSTRUCTIONS : 1. Reset the System Module that causes the alarm.

    2. If resetting of the module does not help, replace the System Module that causes the alarm.

    FAULT NAME : Incompatible unit detectedMEANING : An unsupported unit (for example a WSMA, WTRA, WSPA, WMCM or WTRB) has been detected in the cabinet.INSTRUCTIONS : Replace the unsupported unit with a unit of the correct type.

    FAULT NAME : No baseband capacity for common channelsMEANING : There is not enough common channel capacity to set up any cells to the BTS, because Efficient Baseband or Full Baseband HSDPA is allocated (last WSP/FSP card is fully reserved).INSTRUCTIONS : None

    FAULT NAME : No connection to AXUMEANING : The master WAM detected that the AXU does not respond to polling messages.INSTRUCTIONS : 1. Check for alarms on the AXC.

    2. Restart the AXC remotely. This will also cause a BTS restart.

    3. Change the alarming AXC unit.

    FAULT NAME : No connection to Flexi transport submoduleMEANING : The connection to the Flexi Transport submodule (FTM) is lost.INSTRUCTIONS : Note: Perform the steps below in the listed order until the alarm disappears.

  • 50 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7650 BASE STATION FAULTY

    1. Reset the site.

    2. Replace the Transport submodule, which is located inside the System Module.

    FAULT NAME : No connection to unitMEANING : The connection to a unit that belongs to the BTS configuration has been lost.INSTRUCTIONS : UltraSite, MetroSite, MetroSite 50, Triple-mode:

    1. Check the alarm history, alarming unit and subrack.

    2. If SW updates have been done recently, reload the SW.

    3. If the WAF or WIC is alarming, try recommissioning the site.

    4. Check that the unit is properly connected. If the unit LED does not light up, the unit is faulty. The fault may also be in the WPS unit or backplane.

    5. Check the power cables and connectors as well as the I2C bus cables.

    Cancel alarms: Removing and inserting the WIC, WSM or primary WAM causes a site reset. If both WSCs are removed, inserting the first removed WSC back into the cabinet causes a site reset.

    If the 7650 BASE STATION FAULTY alarm is issued, reset the site. First try to reset the site with the software. If that does not help, replace the alarming unit.

    FlexiBTS:

    1. Check that the module is properly connected. If the module LED does not light up, the module is faulty. Check the alarming module.

    2. Check the alarm history.

    FAULT NAME : Not able to synchronize baseband bus with MEANING : The baseband bus synchronization towards failed.INSTRUCTIONS : Change the faulty module.

    FAULT NAME : Optical Interface Frame clock faultyMEANING : The VCXO does not get correct control voltage from the PLL filter of the clock cleaner. This may happen because of an unsuccessful clock recovery in the optical interface due to a missing or degraded input signal.

  • DN99580892Issue 07E

    51

    RNC Base Station Alarms (7000-7900) 7650 BASE STATION FAULTY

    Id:0900d805806acaaf

    INSTRUCTIONS : 1. Block/unblock the FSM.

    2. Replace the FSM.

    FAULT NAME : Optical interface FPGA sw crc check failedMEANING : The CRC check has failed in three consecutive optical interface FPGA SW downloading attempts.INSTRUCTIONS : Replace the alarming module.

    FAULT NAME : Oven oscillator Missing PulseMEANING : The output signal of the OXCO has some problems and one or more clock pulses are missed.INSTRUCTIONS : 1. Block/unblock the FSM.

    2. Replace the FSM.

    FAULT NAME : Oven oscillator clock missingMEANING : The WSC is not able to deliver the clock signals required by the other units.INSTRUCTIONS : Replace the clock unit.

    FAULT NAME : Oven oscillator clock missingMEANING : The output signal of the OXCO is missing and the FCM cannot deliver the 30.72 MHz System Clock required by the other units.INSTRUCTIONS : 1. Block/unblock the FSM.

    2. Replace the FSM.

    FAULT NAME : Oven oscillator heating failureMEANING : The OCXO warm-up takes too long and the OCXO does not become active within a period of eight minutes from the power-on. The ambient temperature can also be too low or it changes too fast.INSTRUCTIONS : Replace the alarming System Module.

    FAULT NAME : POST test failedMEANING : The unit or module has been tested during the BTS power-on self test (POST) and a failure has been detected.INSTRUCTIONS : 1. Block/unblock the alarming unit/module.

    2. Remove/reinsert the alarming unit/module.

    3. Replace the alarming unit/module.

    FAULT NAME : Power unit output voltage faultMEANING : The output voltage is too low or too high.

    Usually the reason for the fault is the unit itself but in some cases the reason can be the unit that the WPS feeds.

  • 52 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7650 BASE STATION FAULTY

    If a short circuit occurs in the fed unit, it may affect the WPS and the "Output Voltage Fault" alarm is generated.INSTRUCTIONS : 1. Check the other active alarms.

    2. Check the units that are supplied by the alarming WPS.

    3. Check the backplane connectors and cables.

    4. Replace the alarming WPS unit.

    FAULT NAME : R-bus errorMEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode: The bus between the WSP and WTR does not work. The R-bus errors are probably caused by a faulty WSM or WTR.

    FlexiBTS: Error in the FSP or in the connection between the FSP and FCM.INSTRUCTIONS : UltraSite, MetroSite, MetroSite 50, Triple-mode:

    1. If the WSM/WMC also generates an alarm from a WTR unit, check the WTR and WSM cable.

    2. If there are no active WSM/WMC alarms, the reason for the alarm is a faulty WSM/WMC or WSP.

    3. Run a WCDMA BTS loop test to locate the faulty unit.

    4. If the WSP is faulty, block/unblock it.

    5. Replace the faulty unit.

    FlexiBTS:

    1. Check the cabling between the System Module and RF Module.

    2. Check the active RF Module alarms and act accordingly.

    3. Replace the faulty module (System Module).

    FAULT NAME : RP1 synchronization burst errorMEANING : A new RP1 Frame Clock Burst (FCB) burst/message has been received from the RP3-01 interface while processing the previous burst/message.INSTRUCTIONS : 1. Reset the alarming Extension System Module by blocking/unblocking it.

    2. If that does not clear the fault situation, replace the alarming Extension System Module.

    3. If the System Module is the only alarming source or replacing the Extension System Module does not clear the fault

  • DN99580892Issue 07E

    53

    RNC Base Station Alarms (7000-7900) 7650 BASE STATION FAULTY

    Id:0900d805806acaaf

    situation, replace the alarming System Module.

    FAULT NAME : SFN Signal errorMEANING : A system frame number reception fault, an illegal SFN value in uplink.INSTRUCTIONS : 1. If only one FSP in the BTS generates this alarm, the FSP is faulty.

    2. If all FSPs generate this alarm, the FSM is faulty.

    3. Block/unblock the FSM.

    4. If that does not help, replace the faulty module (System Module).

    FAULT NAME : SW does not support commissioning fileMEANING : The software does not support the new commissioning file loaded to the BTS.INSTRUCTIONS : 1. Check and correct the contents of the commissioning file. Load the correct commissioning file to the BTS.

    2. Update the BTS SW.

    FAULT NAME : Starting temperature below minimumMEANING : The temperature measured from the FSPs is less than -10C BTS cannot start properly due to the FSPs that cannot be powered at cold conditions.INSTRUCTIONS : Check the environmental conditions of the site. Heating is needed.

    FAULT NAME : Summing service release from reset failedMEANING : Summing service release from reset failed.INSTRUCTIONS : 1. Reset the System Module.

    2. If a reset does not resolve the fault situation, replace the System Module.

    FAULT NAME : Synchronization failureMEANING : The frame burst phase has moved compared to the internal counter. The FSM has already found the frame synchronization but the FSM frame clock does not match the FSM internal frame clock.INSTRUCTIONS : 1. If only one FSP in the BTS generates this alarm, the FSP is faulty.

    2. If all FSPs generate this alarm, the FSM is faulty.

    3. Block/unblock the FSM.

    4. If that does not help, replace the faulty module (System Module).

  • 54 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7650 BASE STATION FAULTY

    FAULT NAME : Synchronization failure in Optical Interface MEANING : The RP3 channel has lost the frame synchronization state that it had achieved.INSTRUCTIONS : Swap the alarming and working links and then check where the alarm is now reported. If the alarming link remains the same, replace the System Module. If the alarming link changes, replace the RF Module behind that link.

    FAULT NAME : System Module failureMEANING : The FlexiBTS has detected an abnormal operation or a failure in the internal functionality of the System Module.INSTRUCTIONS : Note! Perform the steps below in the listed order until the alarm disappears.

    1. Reset the System Module.

    2. Replace the System Module.

    FAULT NAME : TRANSU synchronization errorMEANING : The RP3 TX/RX state machine or the T-bus receiver has changed its state. The synchronization is lost or the T-bus receiver has not synchronized.INSTRUCTIONS : 1. If only one FSP in the BTS generates this alarm, the FSP is faulty.

    2. If all FSPs generate this alarm, the FSM is faulty.

    3. Block/unblock the FSM.

    4. If that does not help, replace the faulty module (System Module).

    FAULT NAME : Tbus receiver parity faultMEANING : Data or synchronization failure in the System Module, two antenna carriers are affected.INSTRUCTIONS : 1. If only one FSP in the BTS generates this alarm, the FSP is faulty.

    2. If all FSPs generate this alarm, the FSM is faulty.

    3. Block/unblock the FSM.

    4. If that does not help, replace the faulty module (System Module).

    FAULT NAME : Telecom configuration failureMEANING : A telecom slave configurations or registrations failure. A unit RNW configuration failure. A telecom RNW reconfiguration failure.

  • DN99580892Issue 07E

    55

    RNC Base Station Alarms (7000-7900) 7650 BASE STATION FAULTY

    Id:0900d805806acaaf

    Or

    UltraSite, MetroSite, MetroSite 50, Triple-mode: A WSP unit to WAM allocation failure.

    FlexiBTS: An FSP unit to FCM allocation failure.INSTRUCTIONS : UltraSite, MetroSite, MetroSite 50, Triple-mode:

    Block/unblock the alarming unit. If there was an internal failure, the unit needs to be blocked/unblocked to get it initialized/configured again.

    FlexiBTS:

    If there was an internal failure, in the case of an FR, the module needs to be blocked/unblocked to get it initialized/configured again.

    FAULT NAME : Temperature alarmMEANING : The internal temperature of the RF Module or System Module exceeds the threshold value, or the ambient temperature of the module(s) is outside the specified limits.INSTRUCTIONS : Note! Perform the steps below in the listed order until the alarm disappears.

    1. Check the other BTS alarms and act accordingly.

    2. Check the ambient temperature of the BTS/modules. If the ambient temperature is too high, make sure the airflow to the BTS modules is unobstructed, that is, the BTS modules are not covered with anything. If the ambient temperature is too low, it takes a while for the BTS/modules to heat themselves to the threshold value.

    3. Reset the alarming module by blocking/unblocking it.

    4. Replace the alarming module.

    FAULT NAME : Unit SW download failedMEANING : The software update to the unit or subunit has failed.INSTRUCTIONS : 1. Download the BTS SW again.

    2. FCM: Reset the BTS.

    3. If Step 2 does not help, replace the alarming module.

    FAULT NAME : Unit initialization failureMEANING : A unit or an IP address initialisation has failed.INSTRUCTIONS : UltraSite, MetroSite, MetroSite50, Triple-mode:

  • 56 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7650 BASE STATION FAULTY

    1. Block/unblock the alarming unit.

    2. Check if the non-commissioned WAM is the Master WAM. If so, this alarm causes the alarm. Check the alarm history to know why the WAMs' switchover occurred.

    3. If the WAM is the alarm source, check the RNC IP address in the commissioning file and modify the file if needed. If that does not help, perform a power-off reset.

    4. If step 3 does not help, replace the alarming unit.

    FlexiBTS:

    1. Block/unblock the alarming unit. If that does not help, replace the alarming unit.

    2. If the FCM is the alarm source, check the RNC IP address in the commissioning file and modify the file if needed. If that does not help, perform a power-off reset.

    3. If Step 2 does not help, replace the alarming unit.

    FAULT NAME : Unit not supported by current BTS SW versionMEANING : An unsupported unit was found in the BTS. Typically this happens when a new unit version is installed and there is an older BTS SW in use that does not support the new unit version.INSTRUCTIONS : Replace the unit or upgrade the BTS SW.

    FAULT NAME : Unit synchronization failedMEANING : The WAM/WSPC synchronization has failed.INSTRUCTIONS : 1. Block/unblock the alarming unit.

    2. Replace the alarming unit.

    FAULT NAME : Unknown HW resourceMEANING : A unit cannot be identified by its product code or by its physical device address (object ID).INSTRUCTIONS : Replace the alarming unit/module.

    FAULT NAME : Unknown product codeMEANING : A module cannot be identified by its product code but is known by its physical device address (object_ID).INSTRUCTIONS : Replace the alarming module.

    FAULT NAME : Uplink data buffer synchronization failureMEANING : The uplink data buffer loses synchronization.INSTRUCTIONS : 1. If only one FSP in the BTS generates this alarm, the FSP is faulty.

  • DN99580892Issue 07E

    57

    RNC Base Station Alarms (7000-7900) 7650 BASE STATION FAULTY

    Id:0900d805806acaaf

    2. If all FSPs generate this alarm, the FSM is faulty.

    3. Block/unblock the FSM.

    4. If that does not help, replace the faulty module (System Module).

    FAULT NAME : WAM internal errorMEANING : The Telecom SW does not communicate with the ATM SW because of a fault.INSTRUCTIONS : N/A

    FAULT NAME : WCI baseband reference clock failureMEANING : The master or redundant WSC does not generate Baseband Reference Clock (BRCLK) to the WCI because of an internal failure or a clock driver failure in the WSC unit.INSTRUCTIONS : 1. Block/unblock the active WSC unit.

    2. Replace the WCI unit.

    3. Replace both WSC units.

    FAULT NAME : WIB unit AC line break faultMEANING : There is a mains break. The BTS power supply is cut off.INSTRUCTIONS : Check the power supply to the BTS.

    FAULT NAME : WSP PCI-bus failureMEANING : There is a fault in the internal WSP/FSP PCI bus target (DSP) connections. Some of the WSP/FSP DSP processors may be broken and out of use.INSTRUCTIONS : Replace the alarming unit/module.

    CancellingDo not cancel the alarm. The system cancels the alarm automaticallywhen the fault has been corrected.

  • 58 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7651 BASE STATION OPERATION DEGRADED

    29 7651 BASE STATION OPERATION DEGRADEDMeaning

    A major fault (or faults) has occurred in the base station.

    Check the reason for the fault from the supplementary text fieldof the alarm.

    The effect of the fault on the functioning of the network elementdepends on the fault description. For more information, see basestation fault descriptions in WCDMA RAN and I-HSPA System Libraries.

    Supplementary information fields1 rack (cabinet) number

    2 shelf number

    3 slot

    4 type of unit

    5 unit number

    6 subunit number

    For more information, see instructions on Alarm Structure.

    InstructionsVerify the configuration of a BTS by checking the commissioning, cablingand correct installation of the units/modules at the BTS. Make sure theenvironment does not cause the fault.

    Before a unit/module is replaced at the BTS, the site should be reset torecover from any temporary faults which might have caused themalfunctioning of the unit/module. When an active alarm is a 'Start'alarm, a site reset is required to cancel the alarm. If the site reset ormodule block/unblock does not help, replace the faulty unit/module (seethe source of the alarm and instructions fields of the correspondingalarms).

    Below is the list of BTS fault(s) which may have caused this alarm inBTS WN5.0 release. In case of earlier SW release and in case you needmore detailed fault descriptions refer to WCDMA RAN and I-HSPA SystemLibraries. The BTS fault descriptions are also included in BTS SW releasedocumentation. If that does not help, contact your local Nokia SiemensNetworks representative.

  • DN99580892Issue 07E

    59

    RNC Base Station Alarms (7000-7900) 7651 BASE STATION OPERATION DEGRADED

    Id:0900d805806acaaf

    FAULT NAME : 10b8b coding error in Optical Interface device MEANING : The fibre cable has an interference; the data becomes faulty.

    A physical connection failure between the optical interface and the summing function (caused by bad circuit joints, for example).INSTRUCTIONS : 1. Reset the RF Module behind the faulty optical interface by blocking/unblocking it.

    2. If that does not clear the fault situation, replace the RF Module that causes the alarm.

    3. If the System Module is the only source causing the alarm, or replacing the RF Module does not clear the fault situation, replace the System Module that causes the alarm.

    FAULT NAME : 2M external reference missingMEANING : The reference clock monitoring has detected a loss of 2.048MHz signal received from an external reference source, connected to Sync In interface of the System Module.INSTRUCTIONS : Note! Perform the steps below in the listed order until the alarm disappears.

    1. Check the cabling (connected to Sync In interface).

    2. Check that the 2.048MHz reference source is working normally and the 2.048MHz signal is available.

    3. Replace the alarming module.

    FAULT NAME : ATM faultyMEANING : A WAM internal failure.INSTRUCTIONS : 1. If ping to the BTS is working, restart the BTS remotely.

    2. Ping the BTS. If it is not working but ping to the AXC is working, then restart the AXC remotely so that the BTS is also restarted automatically.

    3. Ping the AXC. If it is not working, visit the site and restart the BTS. If this does not help, replace the alarming WAM unit.

    FAULT NAME : ATM processor faultyMEANING : UltraSite, MetroSite, MetroSite 50, Triple-mode:

    There is a fault in the WAM processor SFN interrupt or the SFN

  • 60 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7651 BASE STATION OPERATION DEGRADED

    is not being updated in the WSPC MCU.

    There is a MCU failure in the WAM or the ATM loop test at start-up has failed.

    FlexiBTS:

    There is such a fault in the FSM that the SFN is not being updated in the FSP MCU.INSTRUCTIONS : UltraSite, MetroSite, MetroSite 50, Triple-mode:

    1. If ping to the BTS is working, restart the BTS remotely.

    2. Ping the BTS. If it is not working but ping to the AXC is working, restart the AXC remotely so that the BTS is also automatically restarted.

    3. Ping the AXC. If it is not working, visit the site and restart the BTS. If this does not help, replace the alarming WAM unit.

    FlexiBTS:

    1. Reset the BTS.

    2. If the BTS reset does not help, change the alarming module.

    FAULT NAME : ATM traffic overloadMEANING : There is a buffer overflow caused by a traffic overload. The maximum capacity is exceeded and some data is discarded.INSTRUCTIONS : 1. Check that bandwidths (cells/s) are the same at the BTS, AXC and RNC.

    2. Check the data integrity from the incoming Iub (see Troubleshooting instructions).

    3. Check the other transmission elements' active alarms (see the Alarms for AXC document).

    FAULT NAME : Active clock tuning faultMEANING : The phase measurement cannot be performed in the active WSC or WMC.INSTRUCTIONS : 1. Run fast tuning with BTS Site Manager.

    2. Block/unblock the alarming unit.

    3. Replace the alarming unit.

    Note that because of a fault situation in the active clock, the redundant clock is not tuned. To make sure that the tuning

  • DN99580892Issue 07E

    61

    RNC Base Station Alarms (7000-7900) 7651 BASE STATION OPERATION DEGRADED

    Id:0900d805806acaaf

    is correct, run "Fast Tune BTS Clock" with BTS Site Manager after the switchover when the new WSC is taken into use. If there is a WMC or only one WSC, the tuning continues but the cells remain disabled.

    FAULT NAME : Address mismatch in summingMEANING : There is a baseband bus address mismatch in the summing. There are two possible causes:

    A configuration error (two different baseband units functioning) - after an acknowledgement the fault returns again.

    Data corruption on the bus - appears once when unsynchronized data is sent by the baseband.INSTRUCTIONS : Check the antenna mapping to the local cells in the commissioning file.

    FAULT NAME : Antenna link is downMEANING : Antenna (RP3) link is down: transmitter or receiver drops from synchronization.INSTRUCTIONS : 1. If the alarming module is the Extension System Module (FSM2), restart it. If the alarming module is the System Module (FSM1), restart BTS.

    2. If that does not help, replace the alarming FSM.

    FAULT NAME : BB bus reception errorMEANING : The master frame in the received RF BB frame is not in the correct place related to the internally generated master frame pulse. Either the frame has been set into the wrong place (PI delay) or the data itself is in the wrong place.INSTRUCTIONS : 1. If only one FSP in the BTS generates this alarm, the FSP is faulty.

    2. If all FSPs generate this alarm, the FSM is faulty.

    3. Block/unblock the FSM.

    4. If that does not help, replace the faulty module (System Module).

    FAULT NAME : BB bus reception error (summing device)MEANING : The master frame in the received baseband bus frame is not in the correct place related to the internally generated master frame pulse. Either the frame has been set into the wrong place (PI delay) or the data itself is in the wrong place.

  • 62 DN99580892Issue 07E

    RNC Base Station Alarms (7000-7900)

    Id:0900d805806acaaf

    7651 BASE STATION OPERATION DEGRADED

    INSTRUCTIONS : 1. Check the cables between the System Module and the RF Module.

    2. Replace the unit that causes the alarm (System Module).

    FAULT NAME : BB bus transmission errorMEANING : A decoding error has been detected in the baseband internal link. The data packet is lost or the content is corrupted.

    This situation is also triggered when the links do not synchronize with each other.INSTRUCTIONS : 1. Check the cables between the Master System Module and RF Module/Extension System Module.

    2. Replace the alarming unit (System Module).

    FAULT NAME : BTS Master Clock tuning failureMEANING : The OCXO adjustment area is reaching its limit value. The DAC word value of the OCXO is lower than 205 or greater than 3891 (5 of the total adjustment area). The range for the DAC word is 0 - 4095.INSTRUCTIONS : 1. Start the fast tuning with BTS Site Manager.

    2. Check the reference signal from the FTM.

    3. Reset the site.

    4. If that does not help, replace the system module.

    FAULT NAME : BTS RNC/I-HSPA interface signalling link failureMEANING : An AAL2 signalling link failure. It can be caused by a broken WAM. The most common reason for this alarm is a frequently breaking transmission.INSTRUCTIONS : 1. Check the other transmission elements' active alarms (see the Alarms for AXC document).

    2. Check the BTS and RNC transmission settings.

    3. Reset the AXC.

    4. Change the WAM unit.

    Note! The BTS and the AXC can be restarted remotely.

    FAULT NAME : BTS RNC/I-HSPA interface signalling link failureMEANING : A common NBAP link failure. It can be caused by a transmission network problem. The most common reason for this alarm is a frequently breaking transmission.

  • DN99580892Issue 07E

    63

    RNC Base Station Alarms (7000-7900) 7651 BASE STATION OPERATION DEGRADED

    Id:0900d805806acaaf

    INSTRUCTIONS : UltraSite, MetroSite, MetroSite 50, Triple-mode:

    1. Check the other transmission elements' active alarms (see the Alarms for AXC document).

    2. Check the BTS and RNC transmission settings.

    3. Reset the AXC.

    4. Change the WAM unit.

    Note! The BTS and the AXC can be restarted remotely.

    FlexiBTS:

    1. Reset the BTS.

    2. Check the transmission links to the RNC/I-HSPA adapter.

    3. Check the BTS and RNC/I-HSPA adapter transmission settings.

    4. Replace the System Module.

    FAULT NAME : BTS RNC/I-HSPA interface signalling link failureMEANING : A dedicated Node-B Application Protocol (NBAP) link