Antlia Tecno s.r.l.s. Via Roma 24 20090 Vimodrone Milan Italy phone +39 (0) 2 36518753 www.antliatecno.com [email protected]
Antlia Technologies
✓ A complete range of smart solution to keep healthy comfort
condition on board
✓ Conceived keeping in mind the most recurrent issues in railway
operation
✓ Designed according to the most relevant standard in railway
✓ Different lay-out & principle solution
✓ For all the types of vehicles & operation
✓ Available as basic smart solution to be upgraded according to the real needs
AIR CONDITIONING & CHILLED WATER RAILWAY SYSTEM
ALFA HVAC & WATER COOLING SYSTEMA COMPLETE RANGE OF HVAC & R SOLUTION FOR ALL THE TYPES OF VEHICLE
DOUBLE DECKER
COACHES
LOCOMOTIVE
III compact unit 10-42 kW
V3 compact unit 26-40 kW
D2 compact unit 28-42 kW
modulo split unit 28-42 kW
driver e/B/M/H compact unit 3,5-7,2 kW
TRAM - DMU – EMU
Shelters & containers
MAIN LINE
Antlia Technologies
DMU – EMU
MAIN LINE
METRO
DOUBLE DECKERS
DIESEL LOCOMOTIVE
HYDRAULIC LOCOMOTIES
SHUNTERS
TRAMS - LRU
DIAGNOSTIC VEHICLES
MAINTENANCE VEHICLES
TECHINCAL CONTAINERS
ELECTRIC LOCOMOTIVE
EMU – METRO
MAIN LINE
DOUBLE DECKERS
COMFORT PASSENGERS
COOLING OF TECHNICAL
EQUIPMENT
COMFORT PERSONNELCOMFORT DRIVERS COMFORT DRIVERS
ALFA III RAIL ALFA III LITE ALFA DRIVER RAIL ALFA DRIVER LITE
18 ÷ 36 kW2400 ÷ 4000 m³/h40°C/40% H.R.400V/50Hz–460V/60 Hz
750 Vdc24Vdc (16,8 ÷ 36)R407C – R134a
Fully compliance to the railwayh
standards
2 independent refrigerant circuits
24Vdc emergency ventilation
Free cooling
Continuous air flow control
Compressors frequency
controlloed as option
Fully compliance to the railway
standards
Aluminium frame painted
10 ÷ 16 kW2000 ÷ 2500 m³/h40°C/40% H.R.400V/50Hz–460V/60 Hz
24Vdc (16,8 ÷ 36) or Vca transformerR134a
Compliant to relelvant railway standard
Frame inox, covers aluminium painted
Standard height (400mm) and flat
version (300 mm)
4,2-6 kW800 ÷ 900 m³/h40°C/40% H.R.e version
400V/50Hz–460V/60 Hz24Vdc (16,8 ÷ 36)R 134a - R407C
B version
24/48/72/110 Vdc
R134a
Fully compilance to the railway
standard
Aluminium frame painted
4-7,2 kW800 ÷ 900 m³/h40°C/40% H.R.M version
Power supply: diesel engnie
Aux supply: 24/48/72/110 Vdc
H version
Power supply: Hydrostatic motor
Aux supply: 24/48/72/110 Vdc
R134a
Compliant to relevant railway
standards
Frame carbon steel painted,
covers aluminium
Antlia Tecno s.r.l.s. Via Roma 24 20090 Vimodrone Milan Italy phone +39 (0) 2 36518753 www.antliatecno.com [email protected]
SCRITTA – SFONDO IMMAGINE RAIL
UNIT MODEL
TECHNCAIL DATA
Cooling Capacity:
Air flow: m³/h
Summer condition:
Power supply:
Option:
Aux supply:
Refrigerant
MAIN FEATURES
ALFA III
RAILALFA III
LITEALFA DRIVER
RAILALFA DRIVER
LITE
DIMENSIONS
Length: 2250-2750 mmWidth: 1700 mmHeight: 490 mmWEIGHTFrom 380 to 450 kg
DIMENSIONSLength: 1900 mmWidth: 1200 mmHeight: 300-400 mmWEIGHTFrom 230 to 360 kg
DIMENSIONSLength: 1500 mmWidth: 775 mmHeight: 250 mmWEIGHT: B version: 110 kgE version: 120 kg
DIMENSIONSLength: 1000 mmWidth: 775 mmHeight: 250 mmWEIGHTM version. 90 kgH version: 160 kg
Antlia Technologies
RAILWAY ROOF MOUNTED COMPACT UNITS
✓MAIN TECHNICAL FEATURES OPTIONS
✓smart concept for easy maintenance and operation - heat pump
✓efficient air filtration. Both for fresh than recirculated air flow - Feeded by catenary 750Vdc
✓Continuous air flow control - Compressor frequency control
✓2 independent refrigerant circuits - Free cooling
✓Modular range - communication bus
✓Light weight
✓Reliable components for intensive urban operation
Antlia Technologies
HVAC Railway Products
Antlia Tecno s.r.l.s. Via Roma 24 20090 Vimodrone Milan Italy phone +39 (0) 2 36518753 www.antliatecno.com [email protected]
Cooling Capacity kW 18÷42
Refrigerant Circuits n° 2
Summer Design condition °C/R.H. 40/40
Extreme summer Condition °C 45
Electrical supply in Cooling V/Hz 400/50-460/60
Max electrical consumption in Cooling kVA 10÷26
Max Inrush Current A 65÷95
HFC Refrigerant R407C – R134a
Heating Capacity kW 15 – 30
Heating stages n° 3
Winter Design Condition °C -20
Extreme winter Condition °C -25
Electrical Supply in heating V/Hz 400/460 Vac – 750 Vdc
Max Electrical Consumption in Heating kVA 16-32
Auxiliary Electrical supply V 24 dc
Total Air Flow m3/h 2400-4000
Total Air Flow (free blowing) m3/h 3500-5200
Air Static Pressure Pa 300
Overall Dimensions mm2250 x 1700 x 4902750 x 1700 x 490
Weight kg 380 ÷ 450
ALFA III RAIL
Specifically designed to provide comfort conditions, according to the railway standards, to the passengers
By means a modular approach it can be adapted to all types of urban and regional vehicles
Low environmental approach minimizing energy consumption and reducing the weight
Fully compliance to the railway standards
Modular air flow interfaces to fit with all the vehicle configuration
ROOF MOUNTED COMPACT UNIT FOR TRAMS, EMU’S & DMU’S
Antlia Technologies
HVAC Railway Products
Antlia Tecno s.r.l.s. Via Roma 24 20090 Vimodrone Milan Italy phone +39 (0) 2 36518753 www.antliatecno.com [email protected]
ROOF MOUNTED COMPACT UNIT FOR TECHNICAL CONTAINTERS, SHELTERS AND TRAMS
ALFA III LITECooling Capacity kW 10÷16
Refrigerant Circuits n° 1
Summer Design condition °C/R.H. 40/40
Extreme summer Condition °C 45
Electrical supply in Cooling V/Hz 400/50-460/60
Max electrical consumption in Cooling kVA 6÷9
Max Inrush Current A 45÷55
HFC Refrigerant R134a
Heating Capacity (optional) kW 8 – 15
Heating stages n° 3
Winter Design Condition °C -20
Extreme winter Condition °C -25
Electrical Supply in heating V/Hz 400/460 Vac – 750 Vdc
Max Electrical Consumption in Heating kVA 8,5-16
Auxiliary Electrical supply V 24 dc
Total Air Flow m3/h 2000-2500
Total Air Flow (free blowing) m3/h 3000-3500
Air Static Pressure Pa 250
Overall Dimensions mm1900 x 1200 x 4001900 x 1700 x 300
Weight kg 230 ÷ 360
Specifically designed to cool technical rooms or diagnostic equpment by using air of chilled water
By means a modular approach it can be adapted to shleters and containers than trams
Compliant to the relevant railway standards
Modular air flow interfaces to fit with all the vehicle configuration
✓MAIN TECHNICAL FEATURES OPTIONS
✓smart concept for easy maintenance and operation - heat pump
✓efficient air filtration. Both for fresh than recirculated air flow - chilled water version
✓Continuous air flow control - communication bus
✓Modular range
✓Flat version
✓Reliable components for intensive urban operation
Antlia Technologies
HVAC Railway Products
Antlia Tecno s.r.l.s. Via Roma 24 20090 Vimodrone Milan Italy phone +39 (0) 2 36518753 www.antliatecno.com [email protected]
ROOF MOUNTED COMPACT UNIT FOR DRIVER’S CABS ELECTRICAL LOCOMOTIVES & TRAILERSFEED BY BATTERY OR AUXILIARY CONVERTER
✓MAIN TECHNICAL FEATURES OPTIONS
✓compact unit fto be installed on the roof - separate electrical boar
✓efficient air filtration. Both for fresh than recirculated air flow - communication bus
✓Continuous air flow control to improve quality of regulation,
noise parameters and decrease precooling and preheating time
✓Available power supply 400/460 Vca 50/60 Hz or 24/48/72/110 Vdc
✓Flat design 250 mm height
✓Reliable components for intensive urban operation
Specifically designed to provide comfort conditions, according to the railway standards, to the driver’s area.
Feed by auxiliary converter or directly by battery
Fully complance to the railway standard
ALFA
DRIVER B/e
Cooling Capacity kW 3,5-6
Refrigerant Circuits n° 1
Summer Design condition°C/R.H. 40/40
Extreme summer Condition °C 55 (R134a) – 45 (R407C)
Electrical supply in Cooling V/Hz400/50 - 460/6024 – 48 – 72 - 110
Max electrical consumption in Cooling kVA 1,8-2,9
Max Inrush Current A 35
HFC Refrigerant R134a - R407C
Heating Capacity kW 3-5
Heating stages n° 1
Winter Design Condition °C -20
Extreme winter Condition °C -25
Electrical Supply in Cooling V/Hz400/50 - 460/6024 – 48 - 72 – 110
Max Electrical Consumption in Heating kVA 3,5 – 5,5
Auxiliary Electrical supply V 24 – 48 – 72 -110
Total Air Flow m3/h 650 – 800
Total Air Flow (free blowing) m3/h 900 – 1100
Air Static Pressure Pa 200 – 250
Overall Dimensions motocondenser unit (option chiller module) mm 1500 x 775 x 250
Weight kg 120 -110
Antlia Technologies
HVAC Railway Products
Antlia Tecno s.r.l.s. Via Roma 24 20090 Vimodrone Milan Italy phone +39 (0) 2 36518753 www.antliatecno.com [email protected]
✓MAIN TECHNICAL FEATURES OPTIONS
✓compact unit to be installed on the roof - separate electrical board
✓efficient air filtration both for fresh and recirculated air flow
✓Continuous air flow control to improve quality of regulation,
✓noise parameters and decrease precooling and preheating time
✓Available compressor driven by diesel engine or hydrostatic motor
✓Flat design 250 mm height
✓Reliable components for intensive urban operation
Specifically designed to provide comfort conditions to the driver’s area of shunters, dielsel locomotives and
maintenance vehicles
Commpressor Feed by auxiliary converter or directly by battery
Complant to the relevant railway standard
Cooling Capacity kW 4- 7,2
Refrigerant Circuits n° 1
Summer Design condition°C/R.H. 40/40
Extreme summer Condition °C 55
Winter Design Condition °C -20
Extreme winter Condition °C -25
Auxiliary Electrical supply Vdc 24 – 48 – 72 - 110
Total Air Flow m3/h 800
Total Air Flow (free blowing) m3/h 1100
Air Static Pressure Pa 200
Overall Dimensions motocondenser unit(option chiller module) mm 1000 x 775 x 250
Weight kg 90 - 160
ROOF MOUNTED COMPACT UNIT FOR DRIVER’S CABS DIESEL LOCOMOTIVES & SHUNTERSCOMPRESSOR DRIVEN BY DIESEL ENGINE OR HYDROSTATIC MOTOR
ALFA
DRIVER M/H