+ All Categories
Home > Documents > ALFA HVAC & WATER COOLING SYSTEM mounted AT_f.pdfALFA III LITE Cooling Capacity kW 10÷16...

ALFA HVAC & WATER COOLING SYSTEM mounted AT_f.pdfALFA III LITE Cooling Capacity kW 10÷16...

Date post: 26-Jan-2021
Category:
Upload: others
View: 6 times
Download: 0 times
Share this document with a friend
6
Antlia Tecno s.r.l.s. Via Roma 24 20090 Vimodrone Milan Italy phone +39 (0) 2 36518753 www.antliatecno.com [email protected] Antlia Technologies A complete range of smart solution to keep healthy comfort condition on board Conceived keeping in mind the most recurrent issues in railway operation Designed according to the most relevant standard in railway Different lay-out & principle solution For all the types of vehicles & operation Available as basic smart solution to be upgraded according to the real needs AIR CONDITIONING & CHILLED WATER RAILWAY SYSTEM ALFA HVAC & WATER COOLING SYSTEM A COMPLETE RANGE OF HVAC & R SOLUTION FOR ALL THE TYPES OF VEHICLE DOUBLE DECKER COACHES LOCOMOTIVE III compact unit 10-42 kW V 3 compact unit 26-40 kW D 2 compact unit 28-42 kW modulo split unit 28-42 kW driver e/B/M/H compact unit 3,5-7,2 kW TRAM - DMU – EMU Shelters & containers MAIN LINE
Transcript
  • Antlia Tecno s.r.l.s. Via Roma 24 20090 Vimodrone Milan Italy phone +39 (0) 2 36518753 www.antliatecno.com [email protected]

    Antlia Technologies

    ✓ A complete range of smart solution to keep healthy comfort

    condition on board

    ✓ Conceived keeping in mind the most recurrent issues in railway

    operation

    ✓ Designed according to the most relevant standard in railway

    ✓ Different lay-out & principle solution

    ✓ For all the types of vehicles & operation

    ✓ Available as basic smart solution to be upgraded according to the real needs

    AIR CONDITIONING & CHILLED WATER RAILWAY SYSTEM

    ALFA HVAC & WATER COOLING SYSTEMA COMPLETE RANGE OF HVAC & R SOLUTION FOR ALL THE TYPES OF VEHICLE

    DOUBLE DECKER

    COACHES

    LOCOMOTIVE

    III compact unit 10-42 kW

    V3 compact unit 26-40 kW

    D2 compact unit 28-42 kW

    modulo split unit 28-42 kW

    driver e/B/M/H compact unit 3,5-7,2 kW

    TRAM - DMU – EMU

    Shelters & containers

    MAIN LINE

  • Antlia Technologies

    DMU – EMU

    MAIN LINE

    METRO

    DOUBLE DECKERS

    DIESEL LOCOMOTIVE

    HYDRAULIC LOCOMOTIES

    SHUNTERS

    TRAMS - LRU

    DIAGNOSTIC VEHICLES

    MAINTENANCE VEHICLES

    TECHINCAL CONTAINERS

    ELECTRIC LOCOMOTIVE

    EMU – METRO

    MAIN LINE

    DOUBLE DECKERS

    COMFORT PASSENGERS

    COOLING OF TECHNICAL

    EQUIPMENT

    COMFORT PERSONNELCOMFORT DRIVERS COMFORT DRIVERS

    ALFA III RAIL ALFA III LITE ALFA DRIVER RAIL ALFA DRIVER LITE

    18 ÷ 36 kW2400 ÷ 4000 m³/h40°C/40% H.R.400V/50Hz–460V/60 Hz

    750 Vdc24Vdc (16,8 ÷ 36)R407C – R134a

    Fully compliance to the railwayh

    standards

    2 independent refrigerant circuits

    24Vdc emergency ventilation

    Free cooling

    Continuous air flow control

    Compressors frequency

    controlloed as option

    Fully compliance to the railway

    standards

    Aluminium frame painted

    10 ÷ 16 kW2000 ÷ 2500 m³/h40°C/40% H.R.400V/50Hz–460V/60 Hz

    24Vdc (16,8 ÷ 36) or Vca transformerR134a

    Compliant to relelvant railway standard

    Frame inox, covers aluminium painted

    Standard height (400mm) and flat

    version (300 mm)

    4,2-6 kW800 ÷ 900 m³/h40°C/40% H.R.e version

    400V/50Hz–460V/60 Hz24Vdc (16,8 ÷ 36)R 134a - R407C

    B version

    24/48/72/110 Vdc

    R134a

    Fully compilance to the railway

    standard

    Aluminium frame painted

    4-7,2 kW800 ÷ 900 m³/h40°C/40% H.R.M version

    Power supply: diesel engnie

    Aux supply: 24/48/72/110 Vdc

    H version

    Power supply: Hydrostatic motor

    Aux supply: 24/48/72/110 Vdc

    R134a

    Compliant to relevant railway

    standards

    Frame carbon steel painted,

    covers aluminium

    Antlia Tecno s.r.l.s. Via Roma 24 20090 Vimodrone Milan Italy phone +39 (0) 2 36518753 www.antliatecno.com [email protected]

    SCRITTA – SFONDO IMMAGINE RAIL

    UNIT MODEL

    TECHNCAIL DATA

    Cooling Capacity:

    Air flow: m³/h

    Summer condition:

    Power supply:

    Option:

    Aux supply:

    Refrigerant

    MAIN FEATURES

    ALFA III

    RAILALFA III

    LITEALFA DRIVER

    RAILALFA DRIVER

    LITE

    DIMENSIONS

    Length: 2250-2750 mmWidth: 1700 mmHeight: 490 mmWEIGHTFrom 380 to 450 kg

    DIMENSIONSLength: 1900 mmWidth: 1200 mmHeight: 300-400 mmWEIGHTFrom 230 to 360 kg

    DIMENSIONSLength: 1500 mmWidth: 775 mmHeight: 250 mmWEIGHT: B version: 110 kgE version: 120 kg

    DIMENSIONSLength: 1000 mmWidth: 775 mmHeight: 250 mmWEIGHTM version. 90 kgH version: 160 kg

    Antlia Technologies

    RAILWAY ROOF MOUNTED COMPACT UNITS

  • ✓MAIN TECHNICAL FEATURES OPTIONS

    ✓smart concept for easy maintenance and operation - heat pump

    ✓efficient air filtration. Both for fresh than recirculated air flow - Feeded by catenary 750Vdc

    ✓Continuous air flow control - Compressor frequency control

    ✓2 independent refrigerant circuits - Free cooling

    ✓Modular range - communication bus

    ✓Light weight

    ✓Reliable components for intensive urban operation

    Antlia Technologies

    HVAC Railway Products

    Antlia Tecno s.r.l.s. Via Roma 24 20090 Vimodrone Milan Italy phone +39 (0) 2 36518753 www.antliatecno.com [email protected]

    Cooling Capacity kW 18÷42

    Refrigerant Circuits n° 2

    Summer Design condition °C/R.H. 40/40

    Extreme summer Condition °C 45

    Electrical supply in Cooling V/Hz 400/50-460/60

    Max electrical consumption in Cooling kVA 10÷26

    Max Inrush Current A 65÷95

    HFC Refrigerant R407C – R134a

    Heating Capacity kW 15 – 30

    Heating stages n° 3

    Winter Design Condition °C -20

    Extreme winter Condition °C -25

    Electrical Supply in heating V/Hz 400/460 Vac – 750 Vdc

    Max Electrical Consumption in Heating kVA 16-32

    Auxiliary Electrical supply V 24 dc

    Total Air Flow m3/h 2400-4000

    Total Air Flow (free blowing) m3/h 3500-5200

    Air Static Pressure Pa 300

    Overall Dimensions mm2250 x 1700 x 4902750 x 1700 x 490

    Weight kg 380 ÷ 450

    ALFA III RAIL

    Specifically designed to provide comfort conditions, according to the railway standards, to the passengers

    By means a modular approach it can be adapted to all types of urban and regional vehicles

    Low environmental approach minimizing energy consumption and reducing the weight

    Fully compliance to the railway standards

    Modular air flow interfaces to fit with all the vehicle configuration

    ROOF MOUNTED COMPACT UNIT FOR TRAMS, EMU’S & DMU’S

  • Antlia Technologies

    HVAC Railway Products

    Antlia Tecno s.r.l.s. Via Roma 24 20090 Vimodrone Milan Italy phone +39 (0) 2 36518753 www.antliatecno.com [email protected]

    ROOF MOUNTED COMPACT UNIT FOR TECHNICAL CONTAINTERS, SHELTERS AND TRAMS

    ALFA III LITECooling Capacity kW 10÷16

    Refrigerant Circuits n° 1

    Summer Design condition °C/R.H. 40/40

    Extreme summer Condition °C 45

    Electrical supply in Cooling V/Hz 400/50-460/60

    Max electrical consumption in Cooling kVA 6÷9

    Max Inrush Current A 45÷55

    HFC Refrigerant R134a

    Heating Capacity (optional) kW 8 – 15

    Heating stages n° 3

    Winter Design Condition °C -20

    Extreme winter Condition °C -25

    Electrical Supply in heating V/Hz 400/460 Vac – 750 Vdc

    Max Electrical Consumption in Heating kVA 8,5-16

    Auxiliary Electrical supply V 24 dc

    Total Air Flow m3/h 2000-2500

    Total Air Flow (free blowing) m3/h 3000-3500

    Air Static Pressure Pa 250

    Overall Dimensions mm1900 x 1200 x 4001900 x 1700 x 300

    Weight kg 230 ÷ 360

    Specifically designed to cool technical rooms or diagnostic equpment by using air of chilled water

    By means a modular approach it can be adapted to shleters and containers than trams

    Compliant to the relevant railway standards

    Modular air flow interfaces to fit with all the vehicle configuration

    ✓MAIN TECHNICAL FEATURES OPTIONS

    ✓smart concept for easy maintenance and operation - heat pump

    ✓efficient air filtration. Both for fresh than recirculated air flow - chilled water version

    ✓Continuous air flow control - communication bus

    ✓Modular range

    ✓Flat version

    ✓Reliable components for intensive urban operation

  • Antlia Technologies

    HVAC Railway Products

    Antlia Tecno s.r.l.s. Via Roma 24 20090 Vimodrone Milan Italy phone +39 (0) 2 36518753 www.antliatecno.com [email protected]

    ROOF MOUNTED COMPACT UNIT FOR DRIVER’S CABS ELECTRICAL LOCOMOTIVES & TRAILERSFEED BY BATTERY OR AUXILIARY CONVERTER

    ✓MAIN TECHNICAL FEATURES OPTIONS

    ✓compact unit fto be installed on the roof - separate electrical boar

    ✓efficient air filtration. Both for fresh than recirculated air flow - communication bus

    ✓Continuous air flow control to improve quality of regulation,

    noise parameters and decrease precooling and preheating time

    ✓Available power supply 400/460 Vca 50/60 Hz or 24/48/72/110 Vdc

    ✓Flat design 250 mm height

    ✓Reliable components for intensive urban operation

    Specifically designed to provide comfort conditions, according to the railway standards, to the driver’s area.

    Feed by auxiliary converter or directly by battery

    Fully complance to the railway standard

    ALFA

    DRIVER B/e

    Cooling Capacity kW 3,5-6

    Refrigerant Circuits n° 1

    Summer Design condition°C/R.H. 40/40

    Extreme summer Condition °C 55 (R134a) – 45 (R407C)

    Electrical supply in Cooling V/Hz400/50 - 460/6024 – 48 – 72 - 110

    Max electrical consumption in Cooling kVA 1,8-2,9

    Max Inrush Current A 35

    HFC Refrigerant R134a - R407C

    Heating Capacity kW 3-5

    Heating stages n° 1

    Winter Design Condition °C -20

    Extreme winter Condition °C -25

    Electrical Supply in Cooling V/Hz400/50 - 460/6024 – 48 - 72 – 110

    Max Electrical Consumption in Heating kVA 3,5 – 5,5

    Auxiliary Electrical supply V 24 – 48 – 72 -110

    Total Air Flow m3/h 650 – 800

    Total Air Flow (free blowing) m3/h 900 – 1100

    Air Static Pressure Pa 200 – 250

    Overall Dimensions motocondenser unit (option chiller module) mm 1500 x 775 x 250

    Weight kg 120 -110

  • Antlia Technologies

    HVAC Railway Products

    Antlia Tecno s.r.l.s. Via Roma 24 20090 Vimodrone Milan Italy phone +39 (0) 2 36518753 www.antliatecno.com [email protected]

    ✓MAIN TECHNICAL FEATURES OPTIONS

    ✓compact unit to be installed on the roof - separate electrical board

    ✓efficient air filtration both for fresh and recirculated air flow

    ✓Continuous air flow control to improve quality of regulation,

    ✓noise parameters and decrease precooling and preheating time

    ✓Available compressor driven by diesel engine or hydrostatic motor

    ✓Flat design 250 mm height

    ✓Reliable components for intensive urban operation

    Specifically designed to provide comfort conditions to the driver’s area of shunters, dielsel locomotives and

    maintenance vehicles

    Commpressor Feed by auxiliary converter or directly by battery

    Complant to the relevant railway standard

    Cooling Capacity kW 4- 7,2

    Refrigerant Circuits n° 1

    Summer Design condition°C/R.H. 40/40

    Extreme summer Condition °C 55

    Winter Design Condition °C -20

    Extreme winter Condition °C -25

    Auxiliary Electrical supply Vdc 24 – 48 – 72 - 110

    Total Air Flow m3/h 800

    Total Air Flow (free blowing) m3/h 1100

    Air Static Pressure Pa 200

    Overall Dimensions motocondenser unit(option chiller module) mm 1000 x 775 x 250

    Weight kg 90 - 160

    ROOF MOUNTED COMPACT UNIT FOR DRIVER’S CABS DIESEL LOCOMOTIVES & SHUNTERSCOMPRESSOR DRIVEN BY DIESEL ENGINE OR HYDROSTATIC MOTOR

    ALFA

    DRIVER M/H


Recommended