CatalogueApplied systems
Climate Comfortall Seasons
Heating
air Conditioning
Applied Systems
refrigeration
5
table of ContentsProDUCt Portfolio - air CooleD 04
ProDUCt Portfolio - water CooleD 04
oPtionS Portfolio 04
aCCeSSorieS Portfolio 06
aboUt Daikin 08
enVironmental awareneSS 09
Heat reCoVery 10
reliable & effiCient 12
No matter how large your premises and whatever your air conditioning needs, there is a Daikin chilled water system
to suit your requirements. It is a system that has proved its worth in a multiplicity of situations - from industrial sites to
retail warehouses, hotels and department stores.
The careful development of closely matched compressor/refrigerant combinations, has enabled Daikin to produce
complete ranges of water chillers — genuinely optimised for use with R-134a, R-407C and R-410A refrigerants.
Daikin chillers offer the ultimate in flexibility and control — a reflection of the advanced technology inherent within
them. Unique in their precision, power, low operating noise, easy maintenance and low running costs, Daikin chillers
represent the sure and safe route to an indoor environment that is comfortable, clean and consistent.
As a manufacturer that makes its own refrigerant and compressors, Daikin has total control at the production stage.
Daikin also offers a complete range of air handling units to meet modern day requirements for better indoor air quality
and increased insulation standards.
It is this unique combination of advanced technology, experience and reliability that makes Daikin the obvious choice
and long term solution for the professional.
air CooleD 14
water CooleD 30
ConDenSerleSS CHiller 36
D.i.C.n. 40
HyDraUliC moDUle & bUffer tank 41
fan Coil UnitS 42
air HanDling UnitS 58
meaSUring ConDitionS 62
6
type Compr. refr. mode reference Packshot 0 17.5 200 500 1,000 2,000
air
cool
ed
Swing
r-410a
ewaQ005-007aCV3
SCrollewaQ009-011aCV3
ewaQ009-013aCw1
Swing
r-410a
ewyQ005-007aCV3
SCrollewyQ009-011aCV3
ewyQ009-013aCw1
SCroll
r-407C
eUwaC5-10fbzw1
eUwa*5-24kbzw1
eUwy*5-24kbzw1
r-410a
ewaQ080-260Dayn
ewyQ080-250Dayn
= Cooling only
= heating only
= heat pump
= heating
= Cooling
kw
236
254
209
80 105
152
182
131
2 2 2 2 21 1 2
080
100
130
150
180
210
240
260
18.4
11.6
23.8
5 8 10
1 1 1
509.1 17.1
21 25 34.2
4037 46 54272418
.5
11.9
5 8 10 12 16
20
24
2221111
1 1 1 1 2 2 2
11.3
19.7
22.5
26.5
34.6
46.6
55.3
8 10 12 16 20 245
1 1 1 1 2 2 2
2 2 2 21 1 2 2
2 2 2 2 2 21 1
080
100
130
150
180
210
230
165
199
225
258
87.7
114
281
149 2
50
77 145
183
231
252
100
136
211
7.1 115.2 6
005
006
007
011
1 1 1
8.500
9
1
9.501
0
1 1
13.2
11.0
013
1
900
9
1
011
1
11
5.65
7.75
10 11.5
13
14
6.35
1
1
1
12.5
1
1 1 1 1 1
7.1 115.2 6
005
006
007
011
1 1 1
8.500
9
1
9.501
0
1 1
13.2
0131
900
91
1101
11
type Compr. refr mode reference Products
integrated Hydronics noise & Head Pressure control lwe electrical refrigerant condenser
Single pump contact
twin pump contact Single pump twin pump High eSP pump buff er tank low noise inverter fans High eSP fans High glycol low glycol
evaporator heater tape
mainswitch a / V meter
Dual pressure relief valve
Suction stop valve Coil guards
oPSC oPtC oPSP oPtP oPHP oPbt oPln oPif oPHf oPzH oPzl oP10 oP52 oP57 oP03 oP12 oPCg
air
Cool
ed
Swing r-410aewaQ-aCV3 005-006-007 StD StDewyQ-aCV3 005-006-007 StD StD
SCroll
r-410a
ewaQ-aCV3 009-010-011 StD StDewaQ-aCw1 009-011-013 StD StDewyQ-aCV3 009-010-011 StD StDewyQ-aCw1 009-011-013 StD StD
r-407C
eUwaC-fbzw1 5-8-10 • •eUwan-kbzw1 5-8-10-12-16-20-24 • • • •eUwaP-kbzw1 5-8-10-12-16-20-24 • • • • •eUwab-kbzw1 5-8-10-12-16-20-24 • StD • • • •eUwyn-kbzw1 5-8-10-12-16-20-24 • • • •eUwyP-kbzw1 5-8-10-12-16-20-24 • • • • •eUwyb-kbzw1 5-8-10-12-16-20-24 • StD • • • •
r-410aewaQ-Daynn 080-100-130-150-180-210-240-260 • • • • • • • •(2) • • StD • • •(s) •ewyQ-Daynn 080-100-130-150-180-210-240-260 • • • • • • • •(2) • • StD • • •(s) •
wat
er
Cool
ed
SCroll r-407C ewwP-kbw1n 014-022-028-035-045-055-065 • •
Cond
en-
serle
ss
chill
er
SCroll r-407C ewlP-kbw1n 012-020-026-030-040-055-065 • •
oPtionS Portfolio
(s) op12 & op03 need to be added to meet Swedish national law 1992: 16
(1) Impossible option combination: opZh+opZl
(2) Not available with option oplN
type Compr. refr. mode reference Packshot 0 17.5 200 500 1,000 2,000 9,000
wat
er c
oole
d
SCroll r-407CewwP014-065kbw1newwP090-195kbw1n
Cond
ense
rless
ch
iller
SCroll r-407C ewlP012-65kbw1n
kw
= Cooling only
= heating only
= heating
= Cooling
54.8
41.2
27.3
35.4
16.6
82.7
110
126
143
71.4
165
181
198
214
226
237
248
014
022
028
035
045
055
065
090
110
120
130
145
155
165
175
185
195
100
8613 21 28 32 43 56 65 195
99 112
121
130
142
155
168
177
186
666666444422211 411
211 11 2 2 4 4 4 4 6 6 6 6 6 6
154
4
012
020
026
030
045
055
065
1 1 1 1 2 2 2
Product Portfolio Air cooled
Product Portfolio wAter cooled
oPtion Portfolio
7
type Compr. refr. mode reference Packshot 0 17.5 200 500 1,000 2,000
air
cool
ed
Swing
r-410a
ewaQ005-007aCV3
SCrollewaQ009-011aCV3
ewaQ009-013aCw1
Swing
r-410a
ewyQ005-007aCV3
SCrollewyQ009-011aCV3
ewyQ009-013aCw1
SCroll
r-407C
eUwaC5-10fbzw1
eUwa*5-24kbzw1
eUwy*5-24kbzw1
r-410a
ewaQ080-260Dayn
ewyQ080-250Dayn
SCrew r-134a
ewaD100-410e-SS
ewaD100-400e-Sl
ewaD390-580D-SS
ewaD180-530D-Sl
ewaD180-530D-Sr
ewaD210-490D-SX
ewaD250-620D-XS
ewaD240-600D-Xr
ewaD200-590D-HS
ewyD250-580bzSS
ewyD250-570bzSl
ewaD330-520bzSS/Sl
ewaD330-520bzXS/Xl/Xr
ewaD670-C18CzXS/Xl
ewaD640-C17CzXr
ewaD650-C20C-SS/Sl
ewaD620-C19C-Sr
ewaD760-C22C-XS/Xl
ewaD740-C22C-Xr
ewaD820-C16C-PS/Pl
ewaD810-C16C-Pr
Cond
ensi
ng
units SCrew r-134a
eraD120-490e-SS
eraD120-460e-Sl
= Cooling only
= heating only
= heat pump
= heating
= Cooling
CHillerPortfolio
Portfolio air CooleD UnitS
kw
236
254
256
252
243
249
307
306
295
296
360
370
352
345
413
435
409
488
462
398
209
214
219
209
209
80 105
101
97.9
152
163
165
159
157
182
183
196
187
177
131
138
144
137
134
121
121
116
116
2
1
1
1
1
2
1
1
1
1
2
1
1
1
1
2 2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1 1
1
1
2
1
1
1
1
1
1
1
1
080
100
100
100
130
140
140
140
130
120
120
120
120
150
160
170
160
160
180
180
200
190
180
210
210
220
210
210
240
260
260
250
240
250
310
310
300
300
360
370
350
350
410
440
410
490
460
400
18.4
11.6
23.8
5 8 10
1 1 1
509.1 17.1
21 25 34.2
4037 46 54272418
.5
11.9
5 8 10 12 16
20
24
2221111
1 1 1 1 2 2 2
11.3
19.7
22.5
26.5
34.6
46.6
55.3
8 10 12 16 20 245
1 1 1 1 2 2 2
2 2 2 21 1 2 2
2 2 2 2 2 21 1
080
100
130
150
180
210
230
165
199
225
258
87.7
114
281
149 2
50
77 145
183
231
252
100
136
211
7.1 115.2 6
005
006
007
011
1 1 1
8.500
9
1
9.501
0
1 1
13.2
11.0
013
1
900
9
1
011
1
11
5.65
7.75
10 11.5
13
14
6.35
1
1
1
12.5
1
1 1 1 1 1
7.1 115.2 6
005
006
007
011
1 1 1
8.500
9
1
9.501
0
1 1
13.2
0131
900
91
1101
11
329
358
395
423
515
459
488
330
360
400
420
460
490
520
2222222
329
358
395
423
515
459
488
330
360
400
420
460
490
520
2222222
389
436
466
502
532
556
578
390
440
470
510
530
560
580
2222222
225
261
275
321
370
404
440
477
505
533
230
260
280
320
370
400
440
480
510
530
184
180
2
198
200
2 2
245
250
2 2 2
298
300
2 2 2 2 2 2 2 2
203
247
243
195
231
275
272
208
253
265
302
296
234
271
327
322
256
286
351
345
274
299
376
370
289
309
401
455
306
370
469
512
336
413
524
561
381
451
575
600
415
448
478
514
547
587
492
622
210
250
240
200
230
280
270
210
250
270
300
300
230
270
330
320
260
290
350
350
270
300
380
370
290
310
400
460
310
370
470
510
340
410
520
560
380
450
580
600
420
450
480
510
550
590
490
620
2
2
2
2
2
2 2 2 2 2 2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2 2
2
2
2
2
2
2
2
2
2
2
2
190
177
219
238
252
278
312
366
404
440
477
505
533
220
190
180
240
250
280
310
370
400
440
480
510
530
22 2 2 2 2 2 2 2 2 2 2 2
324
324
349
443
297
297
349
379
379
410
410
443
463
463
475
475
530
530
558
558
615
615
270
270
333
333
250
250
270
270
290
290
320
320
340
330
370
360
380
370
410
400
440
430
460
450
510
490
520
510
580
570
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
2
2
2
2
2
2
2
2
254
248
273
266
292
291
324
316
339
331
365
355
382
372
413
403
436
425
457
448
505
493
522
510
583
567
672
635
647
619
715
756
736
821
809
875
956
1,053
1,132
1,251
1,359
1,439
1,521
890
975
1,074
1,158
1,279
1,390
1,474
1,562
811
866
974
1,041
1,268
1,247
1,302
1,367
1,468
1,550
1,639
1,722
1,813
1,854
1,902
1,959
830
889
1,001
1,280
1,349
1,525
1,409
1,596
1,685
1,768
1,858
1,901
1,953
2,008
789
876
1,020
1,112
1,270
1,321
1,418
1,556
1,623
1,714
1,795
1,833
922
744
832
912
967
1,064
1,152
1,319
1,418
1,419
1,538
1,622
1,714
1,802
1,875
1,922
738
700
832
789
1,236
1,235
1,170
1,037
976
902
852
1,709
1,622
1,631
1,095
1,031
1,450
1,443
1,308
1,332
1,545
1,545
1,802
1,712
670
640
740
700
830
790
900
850
C10
980
C11
C10
C12
C12
C11
C14
C14
C13
C13
C15
C15
C17
C16
C16
C18
C17
2
2
2
2
2
2
2
2
2
2
2
2
2
22
2
2
2
2
2
2
33
3
3
3
760
830
890
990
C10
C11
C12
C13
H14
H15
C16
C17
C18
C19
C20
C21
C22
22222 3 3 3 3 3 3322222
740
820
810
880
960
C10
C11
C13
C14
C15
C16
810
890
870
980
970
C11
C10
C12
C11
C13
C12
C14
C15
C16
C13
H14
H15
C16
C17
C18
C19
C20
C21
C22
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2 2 2
2 2 2
2 3 2 3 3 3 3 3 3 3
650
740
830
910
970
C11
C12
C13
H14
C14
C15
C16
C17
C18
C19
C20
2 2 2 2 2 2 2 2 23 3 3 3 3 3 3
620
720
790
880
C10
920
C11
C13
C12
H14
C15
C16
2 2 2 2 22 2 22 3 3 3
C18
C19
C20
3 3 3
Air cooled: Eurovent certified up to 600kWWater cooled: Eurovent certified up to 1500kWNominal cooling capacities are based on Eurovent conditions: Evaporator: 12°C/7°C — Ambient: 35°CNominal heating capacities are based on Eurovent conditions: Ambient: 7°CDb/6°CWb — Condenser: 40°C/45°C
ECpEN11-404 • 300 • 05/11 • Copyright © DaikinThe present publication supersedes EpCEN10-404.printed on non-chlorinated paper. prepared by la movida. belgium Responsible Editor: Daikin Europe N.V.,Zandvoordestraat 300. b-8400 oostende
type Compr. refr. mode reference Packshot 0 17.5 200 500 1,000 2,000 9,000
wat
er c
oole
d
SCroll r-407CewwP014-065kbw1newwP090-195kbw1n
SCrew
r-134a
ewwD120-560j-SS
ewwD170-600g-SS
ewwD190-650g-XS
ewwD340-C18i-SS
ewwD360-C12i-XS
ewwD380-C11bjynn
r-410a
ewwQ380-C20b-SS
ewwQ420-C21b-XS
Centri-fUgal r-134a
ewwD320-C10fzXS
DwSC
DwDC
Cond
ense
rless
chi
ller
SCroll r-407C ewlP012-65kbw1n
SCrew r-134a
ewlD110-530j-SS
ewlD160-550g-SS
ewlD320-C17i-SS
Portfolio water CooleD UnitS
kw
= Cooling only
= heating only
= heating
= Cooling
1 1
300
4,50
0
2 2
600
9,00
0
550
526
2
480
476
2
420
428
2
380
381
2
360
352
2
320
316
2
280
270
1
240
244
1
190
189
1
160
161
1
110
130
145
165
195
235
265
290
310
330
360
390
430
470
500
530
128
110
143
192
164
237
286
265
307
328
356
383
429
474
502
530
2 2 2 2 2 2 2 222221111
1,134
C12
2
1,038
C11
2
933
950
2
976
C10
2
866
850
2
795
800
2
720
750
2
573
600
1
506
500
1
433
440
1
362
360
1
521
369
445
734
816
895
976
1,05
0
380
460
550
750
850
900
C10
C11
11111111
460
333
394
705
640
538
782
340
400
460
550
650
700
800
1,15
5
3
C12
1,20
4
3
C13
1,27
4
3
C14
1,34
6
3
C15
1,40
1
3
C16
1,45
5
3
C17
1,51
0
3
C18
1 1 1 1 2 2 2
844
850
2
910
900
2
1,02
7C1
0
2
986
950
2
516
422
801
725
639
1,03
7
973
1,36
9
1,27
0
1,11
6
1,15
8
1,44
9
1,86
3
1,73
3
1,57
3
2,02
0
2,15
2
2 2 2 2 2 2 2
420
520
640
730
800
970
C10
C11
C12
C13
C14
C15
C16
C17
C19
C20
C21
1 1 1 1 1 1 2 1 2 2
54.8
41.2
27.3
35.4
16.6
82.7
110
126
143
71.4
165
181
198
214
226
237
248
014
045
035
022
028
014
055
065
090
100
110
022
028
035
045
055
065
090
110
120
130
145
155
165
175
185
195
100
8613 21 28 32 43 56 65 195
99 112
121
130
142
155
168
177
186
666666444422211 411
211 11 2 2 4 4 4 4 6 6 6 6 6 6
140
121
183
159
317
342
367
208
256
285
416
391
465
513
542
571
120
140
150
180
210
250
280
310
330
360
380
400
450
500
530
560
147
216
290
327
431
505
580
617
655
1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2
1 1 21 1 2 2 2 2
186
223
227
307
496
366
408
444
604
541
190 230
280
320
380
400
460
500
550
650
2222221111
220
388.4
411
493
577
660
823
908
990
1,069
1,126
1,203
1,313
460
460
538
630
757
832
919
993
1,072
1
1
1 1 1 1 2 2 2 2 2 2 2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
712
2
264
1
326
1
354
1
434
2
482
2
524
2
585
2
638
2
204
247
310
343
410
456
494
552
610
674
1 21 1 1 2 2 2 2 2
C17
1,42
2
3
C16
1,37
0
3
C15
1,31
9
3
C14
1,26
7
3
C13
1,18
8
3
C12
1,12
5
3
800
788
2
850
850
2
900
919
2
950
966
2
C11
1,07
8
3
C10
1,03
3
3
750
730
2
650
657
2
600
596
2
500
504
1
420
428
1
400
391
1
320
328
1
521
317
429
635
856
1,04
8
320
430
520
640
860
C10
1 1 1 2 2 2
26.8
12.1
20 53.7
31.2
40 62.4
012
020
026
030
045
055
065
1 1 1 1 2 2 2
464
380
727
637
562
796
872
960
1,05
5
1,00
7
1,18
5
1,25
5
1,32
5
1,46
0
1,58
41,
748
1,88
8
2,05
0
2 2 1 2 2 2 2 2 2 2 2 2
380
460
560
640
730
800
860
870
960
C10
C11
C12
C13
C14
C15
C16
C17
C19
C20
1 1 1 1 1 2 2
862
145
155
165
175
185
195
154
120
4
130
201
166
280
334
253
403
372
494
448
556
170
170
210
260
300
320
380
420
460
500
600
210
260
300
320
380
420
460
500
600
1 1 1 1 1 2 2 2 2 2
1,161
1,217
1,363
1,427
1,507
1,227
1,661
1,730
1,790
Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), liquid Chilling packages (lCp) and fan coil units (fCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com
type Compr. refr mode reference Products
integrated Hydronics noise & Head Pressure control lwe electrical refrigerant condenser
Single pump contact
twin pump contact Single pump twin pump High eSP pump buff er tank low noise inverter fans High eSP fans High glycol low glycol
evaporator heater tape
mainswitch a / V meter
Dual pressure relief valve
Suction stop valve Coil guards
oPSC oPtC oPSP oPtP oPHP oPbt oPln oPif oPHf oPzH oPzl oP10 oP52 oP57 oP03 oP12 oPCg
air
Cool
ed
Swing r-410aewaQ-aCV3 005-006-007 StD StDewyQ-aCV3 005-006-007 StD StD
SCroll
r-410a
ewaQ-aCV3 009-010-011 StD StDewaQ-aCw1 009-011-013 StD StDewyQ-aCV3 009-010-011 StD StDewyQ-aCw1 009-011-013 StD StD
r-407C
eUwaC-fbzw1 5-8-10 • •eUwan-kbzw1 5-8-10-12-16-20-24 • • • •eUwaP-kbzw1 5-8-10-12-16-20-24 • • • • •eUwab-kbzw1 5-8-10-12-16-20-24 • StD • • • •eUwyn-kbzw1 5-8-10-12-16-20-24 • • • •eUwyP-kbzw1 5-8-10-12-16-20-24 • • • • •eUwyb-kbzw1 5-8-10-12-16-20-24 • StD • • • •
r-410aewaQ-Daynn 080-100-130-150-180-210-240-260 • • • • • • • •(2) • • StD • • •(s) •ewyQ-Daynn 080-100-130-150-180-210-240-260 • • • • • • • •(2) • • StD • • •(s) •
wat
er
Cool
ed
SCroll r-407C ewwP-kbw1n 014-022-028-035-045-055-065 • •
Cond
en-
serle
ss
chill
er
SCroll r-407C ewlP-kbw1n 012-020-026-030-040-055-065 • •
oPtionS Portfolio
(s) op12 & op03 need to be added to meet Swedish national law 1992: 16
(1) Impossible option combination: opZh+opZl
(2) Not available with option oplN
type Compr. refr. mode reference Packshot 0 17.5 200 500 1,000 2,000 9,000
wat
er c
oole
d
SCroll r-407CewwP014-065kbw1newwP090-195kbw1n
Cond
ense
rless
ch
iller
SCroll r-407C ewlP012-65kbw1n
kw
= Cooling only
= heating only
= heating
= Cooling
54.8
41.2
27.3
35.4
16.6
82.7
110
126
143
71.4
165
181
198
214
226
237
248
014
022
028
035
045
055
065
090
110
120
130
145
155
165
175
185
195
100
8613 21 28 32 43 56 65 195
99 112
121
130
142
155
168
177
186
666666444422211 411
211 11 2 2 4 4 4 4 6 6 6 6 6 6
154
4
012
020
026
030
045
055
065
1 1 1 1 2 2 2
8
AcceSSorieS Portfolio
air-cooled Chillers water-cooled Chillers
ewa/yQ009-011aCV3ewa/yQ009-013aCw1 eUwaC-fbzw1 eUwa/y*-kbzw1 ewa/yQ-Dayn ewwP-kbw1n ewlP-kbw1n ewwD~bj
PanelsekDSSP •ekDSSP-S***ekDDSP •ekPwPro •ekPwProm •Serial Cards & Comm. ModulesekaC10C • • • •ekaCPg •ekaC200aekaC200j •ekaCbaC •ekaClon •ekaClonP •ekaCrS232 •ekaCweb •ekaCbaCmStP •ekaCbaCCertekCm200jekCmlonekCmbaCmStPekCmbaCiPLON GatewayeklonPg •Other Systems & AccessoriesekClwSekCon •ekConUSb •ekmoDem •ekgSmoD •ekrP1Hb •ekrUPCjekrUPCk •ekrUPCSekPV2j •ekPwProeXt •ekgwweb •ekgwmoDem •ekbnPg •ekbmSbnaekbmSmbaekrUmCa • • •ekrUPCekrUPg •eHmC*aV1010 • •eHmC*aV1080 • •GaugesekgaU5/8ka • (5-8)ekgaU10/12ka • (10-12)ekgaU16ka • (16)ekgaU20/24ka • (20-24)Soft starterekSS • • (014-045) • (012-030)Buff er tankekbt •Waterpipe kitekgn210 • (080-210)
ekgn260 • (ewaQ240-260Dayn& ewyQ230-250Dayn)
CHil
lerS
fan
Co
ilS
aCCeSSorieS Portfolio
type: fwm-Dt/Df, fwl-Dt/Df, fwV-Dt/Df 1 2 3 4 6 8 10 fwV fwl fwMDescriptionadditional single row heat exchanger eSrH02a6 eSrH03a6 eSrH06a6 eSrH10a6 x x xelectric heater eeH01a6 eeH02a6 eeH03a6 eeH06a6 eeH10a6 x x x2-pipe 3-way valve e2mV03a6 e2mV06a6 e2mV10a6 x x x4-pipe 3-way valve e4mV03a6 e4mV06a6 e4mV10a6 x x xfan stop thermostat yfSta6 x x xair intake & discharge grille eaiDf02a6 eaiDf03a6 eaiDf06a6 eaiDf10a6 - - xSupporting feet eSfV06a6 eSfV10a6 x - xSupporting feet + grille eSfVg2a6 eSfVg3a6 eSfVg6a6 eSfVg10a6 x - -fresh air intake efa2a6 efa3a6 efa6a6 efa10a6 x - -rear panel erPV2a6 erPV3a6 erPV6a6 erPV10a6 x x -Control electromechanical eCfwmb6 x x xelectronic controller fweC1a, fweC2a, fweC3a x x xmaster slave option ePimSb6 x x xVertical drainpan eDPVa6 x x xHorizontal drainpan eDPHa6 - x xon board installation kit fweCka x x -temperature sensor kit fwtSka x x xrelative humidity sensor kit fwHSka x x xon board fCU controller installation kit fweCka x x -
1. requires electronic controller2. for fwD 12,16,18at/af only motor valve (piping not included)3. water probe included4. optional, electrical installation box with earth terminal kjb212a is required, if controller wires need to be installed in
the wall.5. requires electrical installation box with earth terminal kjb311a.6. requires electrical installation box kjb411a.7. requires installation box krP1H98. (fwC)8. requires installation box krP1ba101 (fwf)9. requires electrical installation box with earth terminal kjb212a, if built in the wall.10. requires valve control PCb ekrP1C1111. i-touch:
• not allowed to use the i-touch for an installation with both fan coils and VrV units.• Can not be used in combination with fan coil units, that use moD bus communication.• no airnet or telephone connection possible.»
12. only 1 of these 4 options can be installed on 1 indoor unit.13. max. 1 krP1H98 box can be mounted on the unit. max. 2 PCb’s can be mounted in 1 krP1H98 box. (fwC)14. max. 2 krP1ba101 boxes can be mounted on the unit. max. 1PCb can be mounted in 1 krP1ba101 box. (fwf)
type: fwD-at/af4 6 8 10 12 16 18
Description
electric heater: small(1)
eDeH04a6 eDeHS06a6 eDeHS10a6 eDeHS12a6 eDeHS18a6
electric heater: big eDeH04a6 eDeHb06a6 eDeHb10a6 eDeHb12a6 eDeHb18a6
2-pipe 3-way valve(2)
eD2mV04a6 eD2mV10a6 eD2mV12a6 eD2mV18a6
4-pipe 3-way valve eD4mV04a6 eD4mV10a6 2xeD2mV12a6 2 x eD2mV18a6
Vertical Drainpan eDDPV10a6 eDDPV18a6
Horizontal Drainpan eDDPH10a6 eDDPH18a6
fan stop thermostat yfSta6
fresh air intake eDmfa04a6 eDmfa06a6 eDmfa10a6 eDmfa12a6 eDmfa18a6
electronic controller (3)
fweC1a
fweC2a
fweC3a
Power interface ePib6
master slave interface ePimSa6
temperature sensor kit fwtSka
relative humidity sensor kit fwHSka
type: fwb-bt2-4 5-7 8-10
Description
additional heat exchanger eaH04a6 eaH07a6 eaH10a63-way valve add. h/e e2mV307a6 e2mV310a63-way valve cooling h/e factory mounted2-way valve add. h/e e2mV207a6 e2mV210a62-way valve cooling h/e factory mountedelectric Heater factory mountedfan stop thermostat yfSta6Power interface - - ePib6master slave interface ePimSb6
electronic controllerfweC1afweC2afweC3a
temperature sensor kit fwtSkarelative humidity sensor kit fwHSkaon board installation kit fweCka
type: fwb-jt/jf
Description
2-pipe 3-way valve mCwCn
4-pipe 3-way valve mCwHn
* to install ekrUmCa => ekaC10C needs to be installed on the unit. * ekaC10C allows direct connection to moDbUS bmS system * to install eklonPg & ekbnPg => ekaCPg needs to be installed on the unit.
15. 2-pipe unit: 1 x valve kit + 1 x installation box for PCb krP1H98 + 1 x valve control PCb ekrP1C114-pipe unit: 2 x valve kit + 1 x installation box for PCb krP1H98 + 1 x valve control PCb ekrP1C 11 (fwC)
16. 2-pipe unit: 1 x valve kit + 1 x installation box for PCb krP1ba101 + 1 x valve control PCb ekrP1C114-pipe unit: 2 x valve kit + 1 x installation box for PCb krP1ba101 + 1 x valve control PCb ekrP1C11 (fwf)»
17. this option is needed to create t1 t2 wire.18. it is possible to change the operation mode, but this will not have an impact on the water temperature. (no feed back to water source) it is not possible to select
the “auto airfl ow” setting.Dry operation can be selected with this remote control, but this function is not available on the fwC model.
19. all options are supplied as kit.20. both parts of the fresh air intake are needed for each unit.
tyPe fwt fwC-bt/bf fwf-bt/bfDescription
Standard wired remote control merCa - -Simplifi ed wired remote control SrC-Cob - -Simplifi ed wired remote control SrC-HPb - -wireless control for cooling only wrC-Cob - -wireless control for heat pump wrC-HPb - -Decoration Panel (ral 9010 - grey sealings) 4-way blow - - byfQ60bDecoration Panel - Standard (ral 9010 - grey sealings) round fl ow - byCQ140Cw1Decoration Panel - white (ral 9010 - white sealings) round fl ow - byCQ140Cw1wSealing member of air discharge outlet - kDbHQ55C140 kDbH44ba60Panel spacer - - kDbQ44b60long-life fi lter - kafP551k160 kafQ441ba60fresh air intake kit - Direct installation type - - kDDQ44Xa60
fresh air intake kit (20% fresh air) - Direct installation type - kDDQ55C140-1(*20) / kDDQ55C140-2 (*20) -
remote controller - wireless - H/P - brC7f532f (*18) brC7e530 (*18)remote controller - wireless - C/o - brC7f533f (*18) brC7e531 (*18)remote controller - wired - brC315D7 (*4)Central remote controller - DCS302Ca51 (*5)electrical box with earth terminal (3 blocks) - kjb311aUnifi ed on/off controller - DCS301ba51 (*9)electrical box with earth terminal (2 blocks) - kjb212aSchedule timer - DSt301ba51 (*6)(*9) DSt301ba51 (*6)(*9)wiring adapter for electrical appendices (1) - krP2a52 (*7) (*12) krP2a52 (*9) (*12)wiring adapter for electrical appendices (2) - krP4aa53 (*7) (*12) krP4aa53 (*9) (*12)installation box for adapter PCb - krP1H98 (*13) krP1ba101 (*17)remote sensor - krCS01-4 krCS01-1intelligent touch controller - DCS601C51C(*6) (*11) DCS601C51C (*6) (*11)electrical installation box - kjb411aoptional PCb for moD-bus connection - ekfCmbCb7 (*8) (*12) ekfCmbCb7 (*8) (*12)
2-way valve - on/off - ekmV2C09b7 (*8) (*10) (*15)ekmV2C09b7 (*8)
(*10) (*16)
3-way valve - on/off - ekmV3C09b7 (*8) (*10) (*15)ekmV3C09b7 (*8)
(*10) (*16)Valve control PCb - ekrP1C11remote “on/off ” and “forced off ” kit - ekroroa (*17)
9
10
Daikin Europe N.V.
about DaikinDaikin has a worldwide reputation based on 85 years’ experience in the successful manufacture of high quality air conditioning equipment for industrial, commercial and residential use.
DAIkIN qUAlITy
Daikin’s much envied quality quite simply stems from the close attention paid to design, production and testing as well as aftersales support. To this end, every component is carefully selected and rigorously tested to verify its contribution to product quality and reliability.
11
SmART CoNTRol bRINgS ComfoRT AND REDUCES ENERgy CoNSUmpTIoN
Inverter technology used in the air cooled mini Chiller (EWAq-AC & EWyq-AC)
allows more precise control of the leaving water condition in function of the
load. This leads to energy savings and high comfort levels, ensuring it is never
too cool or too hot. This is a major advantage over standard fixed speed models,
which use on/off cycling of the compressor, creating greater fluctuations in
control conditions.
environmental awareness DAIkIN AND ThE ENVIRoNmENT
Air conditioning systems provide a significant level of indoor comfort, making
possible optimum working and living conditions in the most extreme climates.
In recent years, motivated by a global awareness of the need to reduce the burdens
on the environment, some manufacturers including Daikin have invested a geat
deal in limiting the negative effects associated with the production and the
operation of air conditioners.
hence, models with energy saving features and improved eco-production
techniques have seen the light of day, making a significant contribution to limiting
the impact on the environment.
12
INVERTER TEChNology
Inverter technology offers improved levels of comfort:
› Energy efficient: continuous matching of load requirement
› Start-up time is reduced by 1/3
› less frequent start/stop cycles
› Reduced sound levels
› high EER /Cop values
Shorter start-up
Temperature remains stableWater temperature
Time
Set temp. Chiller
with Inverter
Chiller
without Inverter
13
Inverter technology for higher efficiency both inverter drive (ID) and variable frequency drive (VfD) are terms used to describe a piece of electrical hardware that is used to start, stop, and control the speed of an electric motor. When fitted to a single screw compressor or scroll compressor, an inverter allows it to continuously adapt the cooling capacity to the requirement of the building load by controlling the speed of the compressor motor.
Traditional systems using electric motors running at full speed even when unloaded waste electricity and with most building energy being consumed by hVAC operations, possible savings are important. With soaring energy prices and global warming concerns, our variable frequency drives for hVAC compressors, pumps, fans and motors are a major efficiency improvement as well as an energy saver and these combine to reduce costs.
The full range of Daikin chillers now come with inverters already fitted or with an inverter alternative.
Principal benefits
• Energy efficient: displacement power factor always > 0.95 Usually the power factor of a motor progressively worsens with the decrease of the power output. however thanks to the inverter, there is no need for additional power factor correction capacitors as the power factor is always > 0.95 and there are no power surges and so costs are constrained.
• quick start-up: start up time reduced by 1/3 The ability to vary the output power in direct relation to the cooling requirements of the system by allowing compressor boosts, gives the inverter chiller a reduced start-up-to-operating-capacity making it possible to achieving building comfort conditions in 1/3 less time than with conventional systems.
• less frequent start/stop cycles and low starting current The inverter technology ensures fewer start/stop cycles as well as ensuring that the start-up current is always lower than current absorbed in the maximum operating conditions (flA). This generates obvious cost savings.
• Seasonal quietness: reduced sound levels low sound levels in partial load conditions are achieved by the variation of compressor frequency, thus ensuring the minimum sound levels at all times.
14
ThE SCRoll CompRESSoR foR CoNTRollED CApACITy:
whatever the requirements of the customer, large systems requiring constant capacity or smaller systems for flexibility, Daikin always provides a reliable and efficient solution.
reliable and efficient
being compact, the Daikin scroll compressor is used with R-407C and R-410A toprovide constant reliability and high efficiency right throughout its service life. Designed for small and medium capacities, the scroll compressors are used with air cooled and water cooled chillers within the range of capacities between 9.1 and 281kW.
Characteristics :
› Compact, simple yet robust design › Absence of valves and oscillating connecting
mechanisms providing maximum reliability › Constant compression guaranteeing low energy consumption › Increased compression efficiency thanks to
the absence of volumetric re-expansion › low sound level › low starting current
ThE SWINg CompRESSoR:
The mini Chiller series EWAq005-007ACV3 & EWyq005-007ACV3 are equipped with a swing compressor. This innovative design by Daikin with fewer moving parts allows smoother more reliable operation with low vibration and low noise levels. The high efficiency motor reduces energy consumption resulting in energy cost savings.
swing
the piston which the bladeand the roller unified
ref. gas
Swing bush scroll
15
1
2
38 4
6
910
7
12
11
5
As standard, condensers for air cooled chillers are given anti-corrosion treatment. This treatment significantly increases resistance to acid rain and saline corrosion. Depending on the capacities and models, treatments are of the following type:
example of acrylic treatment
1. Casing2. Slide valve3. Screw rotor4. bearing5. motor6. gate rotor
7. 2nd stage oil separator8. Demister (oil separator)9. Refrigerant suction10. Refrigerant discharge11. Compressor terminal + CTp12. Stepper motor
ThE SINglE SCREW STEplESS CompRESSoR foR hIgh CApACIT y:
Characteristics :
› optimal performance through stepless capacity control in function of the chilled water temperature. The unit capacity is infinitely variable from 30 - 100% on single circuit units and 15 - 100% on dual circuit units.
› Compact, simple yet robust construction. › Using a main single screw and two gate rotors, axial and
radial forces are balanced thanks to the symmetrical compression guaranteeing low bearing loads.
› Renowned for its low noise levels the double walled casing design and integrated oil separator, add to the attenuation effect.
› gate rotors made of polymer material result in closer tolerances with main screw and reduced friction greatly improving compressor efficiency and lifetime.
› No oil pump necessary – lubrication based on differential pressure principle.
› Easy access to both compressor and safety devices › Star delta starter with low starting current as standard
The heart of the larger Daikin chillers is a semi hermetic single screw compressor, designed, tested and manufactured in Daikin’s own laboratories, in order to meet the highest capacity, performance and maintenance specifications. This compressor has been especially developed for operation with R-410A, R-134a or R-407C refrigerant, guaranteeing unequalled reliabi-lity and many years of efficient operation. The bearing life is 100,000hrs with inspection and maintenance intervals every 40,000hrs.
STANDARD ANTI -CoRRoSIoN TREATmENT
screw
Acrylic treatment (Daikin ref PE)
The aluminium fins are coated with an acrylic resin and a hydrophilic film. Epoxy Treatment
The aluminium fins are black epoxy coated.
16
air Cooled
ewaQ-aCV3 & ewaQ-aCw1 16
ewyQ-aCV3 & ewyQ-aCw1 18
eUwaC-fbzw1 20
eUwa*-kbzw1 22
eUwy*-kbzw1 24
ewaQ-Dayn 26
ewyQ-Dayn 28
in the chilled water market, chillers of the air cooled
type are most frequently used. out of its wide range
of chillers in cooling only or heat pump version,
with or without integrated hydronic components,
Daikin always offers you a chiller fitting your
application needs.
TAblE of CoNTENTS
Daikin has taken great care to match major chiller components and refrigerant combinations to a point where high efficiency ranges of technically advanced and closely optimised air and water cooled units are now widely available for use with R-410A, R-407C and R-134a refrigerants.
A IR CoolED ChIllER
1. Temperature sensor2. filter3. Shut-off valve4. pump
5. pressure port6. flow switch7. Air purge8. pressure gauge
9. balancing valve10. Drain valve11. Charging valve12. Safety valve
57 3 2 4 5
101198561
1
t
t
t
EVA
poRA
ToR
To fan coil units
buffer Tank
Expa
nsio
nve
ssel
Chillers
swing scroll screw
18
ewAQ-Ac air cooled mini chiller inverter
Digital Controller
StrengtHS › optimised for use with R-410A › Inverter controlled swing compressor
(size 005-007) - precise temperature control
› Inverter controlled scroll compressor (size 009-011)
› low operating sound level › Easy ‘plug and play installation’ › Wide operating range › Integrated hydronics
oPtionS (faCtory moUnteD) › Evaporator heater tape
oPtion kit › Digital Input/output pCp (size 009-013 only)
Control › leaving water control
aVailable inPUtS › Voltage free contact:
- oN/off Schedule timer:- oN/off - Silent operation
s c r o l ls w i n g
19
ewaQ005-007aCV3 + ewaQ009-011aCV3 / ewaQ009-013aCw1
Cooling onlycapacity class
ewAQ-AcV3 ewAQ-Acw1005 006 007 009 010 011 009 011 013
Cooling capacity nom. kw 5.2 6.0 7.1 8.5 9.5 11.0 9.0 11.0 13.2Power input Cooling nom. kw 1.89 2.35 2.95 2.74 3.19 3.82 2.96 3.82 5.10 eer 2.75 2.55 2.41 3.11 2.98 2.88 3.04 2.88 2.59 eSeer 3.75 3.83 3.87 4.57 4.52 4.46 4.68 4.63 4.52Dimensions Unit HeightxwidthxDepth mm 805x1,190x360 1,435x1,418x382weight Unit kg 100 180water heat exchanger
type brazed platewater volume l - 1.01nominal water flow
Cooling l/min 14.9 17.2 20.4 24.4 27.2 31.5 25.8 31.5 37.8
air heat exchanger type tube type Hi-XSSPump nominal eSP unit Cooling kPa 49.4 45.1 38.3 58.0 54.6 49.1 56.4 49.1 40.9Hydraulic components expansion vessel Volume l 6 10 10fan air flow rate Cooling nom. m³/min - 96 100 97 -fan motor Speed Cooling nom. rpm - 780
Steps - 8Sound power level Cooling nom. dba 62 63 64 66Sound pressure level
Cooling nom. dba 48 50 51 52night quiet mode Cooling dba - 45 46
Compressor type Hermetically sealed swing compressor Hermetically sealed scroll compressoroperation range water side Cooling min.~max. °CDb 5~20 5~22
air side Cooling min.~max. °CDb 10~43 10~46refrigerant type r-410a
Charge kg 1.7 2.95Control electronic expansion valveCircuits Quantity 1
water circuit Piping connections diameter inch - g 5/4" (female)Piping inch - 5/4"
Piping connections
water heat exchanger inlet / outlet 1" mbSP -water heat exchanger drain Hose nipple 1/2" fbSP -
Power supply Phase / frequency / Voltage Hz / V 1~ / 50 / 230 3n~ / 50 / 400
20
ewYQ-Ac air cooled mini chiller inverter
Digital Controller
StrengtHS › optimised for use with R-410A › Inverter controlled swing compressor › (size 005-007)
- precise temperature control › Inverter controlled scroll compressor
(size 009-011) › low operating sound level › Easy ‘plug and play’ installation › Integrated hydronics › Wide operating range
oPtionS (faCtory moUnteD) › Evaporator heater tape
oPtion kit › Digital Input/output pCp (size 009-013 only)
Control › leaving water control › Setpoint in heating & cooling
aVailable inPUtS › Voltage free contact:
- oN/off- Cooling/heating changeover
› Schedule timer:- oN/off- Dual setpoint- Silent operation
s c r o l ls w i n g
21
ewyQ005-007aCV3 + ewyQ009-011aCV3/ewyQ009-013aCw1
Heating & CoolingCapacity class
ewyQ-aCV3 ewyQ-aCw1005 006 007 009 010 011 009 011 013
Cooling capacity nom. kw 5.2 6.0 7.1 8.5 9.5 11.0 9.0 11.0 13.2Heating capacity nom. kw 5.65 6.35 7.75 10.0 11.5 13.0 11.0 12.5 14.0Power input Cooling nom. kw 1.89 2.35 2.95 2.74 3.19 3.82 2.96 3.82 5.10
Heating nom. kw 1.97 2.24 2.83 2.91 3.38 3.86 3.23 3.70 4.19 eer 2.75 2.55 2.41 4.37 2.98 2.88 3.04 2.88 2.59 CoP 2.87 2.83 2.74 3.44 3.40 3.37 3.41 3.38 3.34 eSeer - 4.57 4.52 4.46 4.68 4.63 4.52Dimensions Unit HeightxwidthxDepth mm 805x1,190x360 1,435x1,418x382weight Unit kg 100 180
operation weight kg 104 -water heat exchanger
type brazed platewater volume l - 1.01nominal water flow
Cooling l/min 14.9 17.2 20.4 24.4 27.2 31.5 25.8 31.5 37.8 Heating l/min 17.5 19.5 23.5 28.7 33.0 37.3 31.5 35.8 40.1
air heat exchanger type tube type Hi-XSS Pump nominal eSP unit Cooling kPa 49.4 45.1 38.3 58.0 54.6 49.1 56.4 49.1 40.9Hydraulic components expansion vessel Volume l 6 10fan air flow rate Cooling nom. m³/min - 96 100 97 -
Heating nom. m³/min - 90 -fan motor Speed Cooling nom. rpm - 780
Heating nom. rpm - 760Steps - 8
Sound power level Cooling nom. dba 62 63 64 66 Heating nom. dba - 64
Sound pressure level
Cooling nom. dba 48 50 51 52 Heating nom. dba 48 49 51night quiet mode
Cooling dba - 45 46Heating dba - 42 43
Compressor type Hermetically sealed swing compressor Hermetically sealed scroll compressoroperation range water side Cooling min.~max. °CDb 5~20 5~22
Heating min.~max. °CDb 25~50 25~50 air side Cooling min.~max. °CDb 10~43 10~46
Heating min.~max. °CDb -15~25 -15~35refrigerant type r-410a
Charge kg 1.7 2.95Control electronic expansion valveCircuits Quantity 1
water circuit Piping connections diameter inch - g 5/4" (female)Piping inch - 5/4"
Piping connections
water heat exchanger inlet / outlet 1" mbSP -water heat exchanger drain Hose nipple 1/2" fbSP -
Power supply Phase / frequency / Voltage Hz / V 1~ / 50 / 230 3n~ / 50 / 400
euwAc-fBZw1 air cooled chiller with centrifugal fan
s c r o l l
StrengtHS › optimised for use with R-407C › Daikin scroll compressor › Electronic DDC controller › Standard phase sequence controller › maximum external static pressure (ESp): 150pa › pressure gauges › Standard operation range down to -10°C › Regulating switch › Water inlet or outlet temperature control › Input contacts/available outputs › Input: on/off (per circuit), pump/flow switch › outputs: compressor operation, summary
alarm, pump relay contact › Compatible with hydraulic module › µC² SE controller
oPtionS (faCtory moUnteD) › Chilled water temperature
down to - 5°C (opZh) or -10°C (opZl)* opZh: option lWE high glycol
opZl: option lWE low glycol
aCCeSSorieS (kit) › Address card for connection to bmS or
remote user interface (EkAC10C) › Remoted installed user interface (EkRUmCA)
* To install EkRUmCA -> EkAC10C needs to be installed on the unit
Control › Water inlet temperature control
aVailable inPUtS / oUtPUtSinput › oN / off (per circuit) › pump / flow switch
output › Compressor operation › Summary alarm › pump relay contact
22
µC2 Se
eUwaC8fbzw1
23
Cooling onlyCapacity class 5 8 10Cooling capacity nom. kw 11.6 18.4 23.8Capacity steps % 100-0Power input Cooling nom. kw 5.2 7.66 9.67eer 2.23 2.40 2.46Dimensions Unit HeightxwidthxDepth mm 1,345x856x630 1,290x1,180x630 1,395x1,330x630weight Unit kg 164 224 261
operation weight kg 166 228 266water heat exchanger - evaporator
type brazed plate, one per circuitminimum water volume in the system l 101 153 212water flow rate nom. l/min 33 53 68nominal water pressure drop
Cooling Heat exchanger
kPa 26 42 48
model type aC70-24 aC70-34 aC70-40Quantity 1
air heat exchanger type Cross fin coil/Hi-X tubes and Pe coated waffle louvre finsfan air flow rate nom. m³/min 70.2 109.8 126Sound power level Cooling nom. dba 63 66 69Compressor type Hermetically sealed scroll compressoroperation range water side Cooling min.~max. °CDb -10 (oPzl) ~ 21
air side Cooling min.~max. °CDb -10 ~ 43refrigerant type r-407C
Control thermostatic expansion valveCircuits Quantity 1
refrigerant circuit Charge kg 2.1 3.9 4.7Piping connections
evaporator water inlet/outlet fbSP 1"evaporator water drain field installation
Power supply Phase / frequency / Voltage Hz / V 3n~ / 50 / 400
euwA*-kBZw1 air cooled chiller
s c r o l l
StrengtHS › optimised for use with R-407C › Daikin scroll compressor › Reduced installation time thanks to
integrated pump and and/or buffer tank › possibility for a 200l buffer tank › low operating sound level › Easy maintenance › main switch › Water flow switch › 3 different design options available:
- EUWAN chiller without integrated hydraulic module ; - EUWAp chiller with integrated hydraulic module
(pump, expansion vessel, hydraulic components) ; - EUWAb chiller with integrated hydraulic
module (buffer tank, pump, expansion vessel, hydraulic components)
› µC² SE controller
oPtionS (faCtory moUnteD) › Chilled water temperature down
to - 5°C (opZh) or -10°C (opZl) › high ESp fans (50pa) (ophf) › pump size up (ophp)
* opZh: option lWE high glycol
opZl: option lWE low glycol
aCCeSSorieS (kit) › Refrigerant pressure gauges
(EkgAU5/8/10/12/16/20/24kA) › 200l buffer tank (EkbT, see EkbT page in this catalogue) › Soft starter kit (EkSS) › Address card for connection to bmS or
remote user interface (EkAC10C) › Remote installed user interface (EkRUmCA)
* To install EkRUmCA -> EkAC10C needs to be installed on the unit
Control › Water inlet temperature control
aVailable inPUtS / oUtPUtSinput › Remote oN / off › pump contact
output › Compressor operation › Summary alarm › pump relay contact
air purge
buffer tank
water Pressure gauge
expansion vessel
Drain
Pressure port
Safety valve
flow switch
Pump
water flow adjusting valve
HyDraUliC CirCUit ComPonentS
24
µC2 Se
eUwan: › Scroll compressor › main isolator switch › Water flow switch › filter › Condenser protection grille › All year operation
eUwaP = eUwan + › pump › Expansion vessel › Adjusting valve › Drain › Water pressure gauge › pressure relief valve
eUwab = eUwaP + › buffer tank
25
eUwa*16kbzw1
Cooling onlyCapacity class n5 P5 b5 n8 P8 b8 n10 P10 b10 n12 P12 b12 n16 P16 b16 n20 P20 b20 n24 P24 b24Cooling capacity nom. kw 11.3 19.7 22.5 26.5 34.6 46.6 55.3 Capacity steps % 0-100 0-50-100Power input Cooling nom. kw 4.48 7.27 8.64 11.50 14.70 17.90 23.80eer 2.53 2.46 2.60 2.30 2.35 2.60 2.32Dimensions Unit HeightxwidthxDepth mm 1,230x1,290x734 1,450x1,290x734 1,321x2,580x734 1,541x2,580x734weight Unit kg 150 168 180 215 229 241 245 259 271 248 262 274 430 448 460 490 508 520 496 514 526
operation weight kg 152 171 239 218 232 300 248 262 330 251 265 335 436 457 525 496 518 545 503 524 592water heat exchanger
type brazed platewater volume l 1.14 1.615 1.9 2.375 2.964 3.9 4.524nominal water flow Cooling l/min 32 51 64 76 99 134 158nominal water pressure drop
Cooling Heat exchanger
kPa 24 38 43 37 22
air heat exchanger type Cross fin coil/Hi-X tubes and Pe coated waffle louvre finsHydraulic components expansion vessel Volume l - 12 - 12 - 12 - 12 - 12 - 12 - 12fan group air flow rate Cooling nom. m³/min 160 (per 2 fans) 170 (per 2 fans)fan group 2 air flow rate Cooling nom. m³/min - 170 (per 2 fans)Sound power level Cooling nom. dba 67 76 78 79 81Compressor type Hermetically sealed scroll compressoroperation range water side Cooling min.~max. °CDb -10 (oPzl) ~ 25
air side Cooling min.~max. °CDb -15 ~ 43refrigerant type r-407C
Control thermostatic expansion valveCircuits Quantity 1 2
refrigerant circuit Charge kg 3.9 4.6 5.9 6.0 4.6 5.9 6.0refrigerant circuit 2 Charge kg - 4.6 5.9 6.0water circuit Piping connections diameter inch g 1"1/4 (male) 2" male
Piping inch 1-1/4" -Power supply Phase / frequency / Voltage Hz / V 3n~ / 50 / 400
26
euwY*-kBZw1 air cooled chiller
s c r o l l
StrengtHS › optimised for use with R-407C › Daikin scroll compressor › Reduced installation time thanks to
integrated pump and/or buffer tank › possibility for a 200l buffer tank › low operating sound level › Easy maintenance › main switch › Water flow switch › 3 different design options available:
- EUWyN chiller without integrated hydraulic module;- EUWyp chiller with integrated hydraulic module
(pump, expansion vessel, hydraulic components); - EUWyb chiller with integrated hydraulic
module (buffer tank, pump, expansion vessel, hydraulic components)
› µC² SE controller
oPtionS (faCtory moUnteD) › Chilled water temperature down
to - 5°C (opZh) or -10°C (opZl) › high ESp fans (50pa) (ophf) › pump size up (ophp)
* opZh: option lWE high glycol
opZl: option lWE low glycol
aCCeSSorieS (kit) › Refrigerant pressure gauges
(EkgAU5/8/10/12/16/20/24kA) › 200l buffer tank (EkbT, see EkbT page in this catalogue) › Soft starter kit (EkSS) › Address card for connection to bmS or
remote user interface (EkAC10C) › Remote installed user interface (EkRUmCA)
* To install EkRUmCA -> EkAC10C needs to be installed on the unit
Control › Water inlet temperature control
aVailable inPUtS / oUtPUtSinput › Remote oN / off › pump contact › Remote cool / heat selection
output › Compressor operation › Summary alarm › pump relay contact
µC2 Se
eUwy*16kbzw1
eUwyn: Standard equipment › Scroll compressor › main isolator switch › Water flow switch › filter › Condenser protection grille. › All year operation
eUwyP = eUwyn + › pump › Expansion vessel › Adjusting valve › Drain › Water pressure gauge › pressure relief valve
eUwyb = eUwyP + › buffer tank
27
Heating & CoolingCapacity class n5 P5 b5 n8 P8 b8 n10 P10 b10 n12 P12 b12 n16 P16 b16 n20 P20 b20 n24 P24 b24Cooling capacity nom. kw 9.1 17.1 21.0 25.0 34.2 40 50.0Heating capacity nom. kw 11.9 18.5 24.0 27.0 37.0 46 54.0Capacity steps % 0-100 0-50-100Power input Cooling nom. kw 3.77 7.38 8.49 11.3 14.8 16.2 22.6
Heating nom. kw 4.56 7.01 8.98 10.7 14.10 17.3 21.4eer 2.41 2.32 2.47 2.21 2.3 2.5 2.2CoP 2.61 2.64 2.67 2.52 2.62 2.66 2.52Dimensions Unit HeightxwidthxDepth mm 1,230x1,290x734 1,450x1,290x734 1,321x2,580x734 1,541x2,580x734weight Unit kg 163 181 193 227 241 253 258 272 284 258 272 284 455 473 485 516 534 546 516 534 546
operation weight kg 165 184 252 230 244 312 261 275 343 261 275 343 461 482 550 522 544 612 522 544 612water heat exchanger
type brazed platewater volume l 1.140 1.615 1.900 2.375 2.964 3.900 4.524nominal water flow
Cooling l/min 26 49 60 72 98 115 143Heating l/min 34 53 69 77 106 132 155
nominal water pressure drop
Cooling filter kPa 10 25 24 33 12 19Heating filter kPa 17 29 31 38 14 16 22
air heat exchanger type Cross fin coil/Hi-X tubes and Pe coated waffle louvre finsHydraulic components expansion vessel Volume l - 12 - 12 - 12 - 12 - 12 - 12 - 12fan group air flow rate Cooling nom. m³/min 160 (per 2 fans) 170 (per 2 fans)fan group 2 air flow rate Cooling nom. m³/min - 170 (per 2 fans)Sound power level Cooling nom. dba 67 76 78 79 81Compressor type Hermetically sealed scroll compressoroperation range water side Cooling min.~max. °CDb -10(oPzl) ~ 20
Heating min.~max. °CDb 35 ~ 50air side Cooling min.~max. °CDb -15 ~ 43
Heating min.~max. °CDb -10 ~ 21refrigerant type r-407C
Control thermostatic expansion valveCircuits Quantity 1 2
refrigerant circuit Charge kg 4.6 4.7 5.4 5.1 5.4 5.6refrigerant circuit 2 Charge kg - 5.1 5.4 5.6water circuit Piping connections diameter inch g 1"1/4 (male) 2" male
Piping inch 1-1/4" 2"Power supply Phase / frequency / Voltage Hz / V 3n~ / 50 / 400
ewAQ-dAYn air cooled chiller, multiple scroll
PCaSo
s c r o l l
StrengtHS › optimised for use with R-410A refrigerant › multiple compressors per circuit › Reliable and efficient scroll with high EER values › Anti-corrosion treated aluminium coils › low operating sound level › Easy ‘plug and play’ installation › fans protected against abnormal operation
(4 - 8 fans depending on unit size) › Safety valves in each circuit › Electronic circuit breakers › Electronic expansion valve › True dual plate brazed plate heat exchanger › All hydronics can be accessed easily from
3 sides (no surrounding cabinet) › Separate switchbox for easy access › Compressors and controls at unit side › Increased reliability via 2 independent
refrigerant circuits (EWAq130-260DAyN) › Double circuit heat exchanger (from >100 kW) › Non hermetic filter/dryer › Daikin pcaso controller with user friendly
and powerful lCD interface
oPtionS (faCtory moUnteD) › Single pump contactor (opSC) › Twin pump contactor (opTC) › Single pump (opSp) › Twin pump (opTp) (1 pump casing, dual motor) › high ESp pump (ophp) (single pump only) › buffer tank (opbT) › Inverter fans (opIf) (Not available with option oplN) › glycol 0°C / -10°C (opZl) › Evaporator heater tape (op10) › option valves
(discharge, liquid line and suction stop valve: op12) › A-meter / V-meter (op57) › low Noise (oplN) (=opIf + compressor housing) › Condenser protection grills (opCg)
aCCeSSorieS (kit) › gateway for loN (EkloNpg) › gateway for bACNET (EkbNpg) › Address card (EkACpg) › Remote user interface (EkRUpg)
28
ewaQ130,150Dayn
29
Cooling onlyCapacity class 080 100 130 150 180 210 240 260Cooling capacity nom. kw 80 105 131 152 182 209 236 254Capacity steps %
0-50-100 0-25-50-75-10021/29-
43/50/57-71/79-100
0-25-50-75-10022/28-
40/50/56-72/78-100
0-25-50-75-100
Power input Cooling nom. kw 26.4 36.2 46.6 56.3 64.5 74.6 82.8 94.0eer 3.03 2.90 2.81 2.70 2.82 2.80 2.85 2.70eSeer 4.12 4.00 4.34 4.22 4.36 4.32 4.20 4.00Dimensions Unit HeightxwidthxDepth mm 2,311x2,000x2,566 2,311x2,000x2,631 2,311x2,000x3,081 2,311x2,000x4,850weight Unit kg 1,350 1,400 1,500 1,550 1,800 1,850 3,150 3,250
operation weight kg 1,365 1,415 1,517 1,569 1,825 1,877 3,189 3,292water heat exchanger
type brazed platenominal water flow Cooling l/min 229 301 377 436 522 599 677 728nominal water pressure drop
Cooling total kPa 59 58 52 49 52 53 51 47
air heat exchanger type Cross fin coil/Hi-Xss tubes and poly ethylene coated waffle finsfan air flow rate nom. m³/min 780 800 860 1,290 1,600
Speed rpm 880 900 970 900Sound power level Cooling nom. dba 86 88 89 90 91Compressor type Scroll compressoroperation range water side Cooling min.~max. °CDb -10 (oPzl) ~ 25
air side Cooling min.~max. °CDb -15 ~ 43refrigerant type r-410a
Charge kg 33 19 25 29 28 39Control electronic expansion valveCircuits Quantity 1 2
Piping connections
water heat exchanger inlet / outlet 3" oD 3"water heat exchanger drain 1/2"g
Power supply Phase / frequency / Voltage Hz / V 3~ / 50 / 400
ewYQ-dAYn air cooled chiller, multiple scroll
PCaSo
s c r o l l
StrengtHS › optimised for use with R-410A refrigerant › multiple compressors per circuit › Reliable and efficient scroll with high EER values › Anti-corrosion treated aluminium coils › low operating sound level › Easy ‘plug and play’ installation › fans protected against abnormal operation
(4 - 8 fans depending on unit size) › Safety valves in each circuit › Electronic circuit breakers › Electronic expansion valve › True dual plate brazed plate heat exchanger › All hydronics can be accessed easily from
3 sides (no surrounding cabinet) › Separate switchbox for easy access › Compressors and controls at unit side › Increased reliability via 2 independent
refrigerant circuits (EWyq130-250DAyN) › Double circuit heat exchanger (from >100 kW) › Non hermetic filter/dryer › Daikin pcaso controller with user friendly
and powerful lCD interface
oPtionS (faCtory moUnteD) › Single pump contactor (opSC) › Twin pump contactor (opTC) › Single pump (opSp) › Twin pump (opTp) (1 pump casing, dual motor) › high ESp pump (ophp) (single pump only) › buffer tank (opbT) › Inverter fans (opIf) (Not available with option oplN) › glycol 0°C / -10°C (opZl) › Dual pressure relief valve (op03) › Evaporator heater tape (op10) › option valves
(discharge, liquid line and suction stop valve: op12) › A-meter / V-meter (op57) › low Noise (oplN) (=opIf + compressor housing) › Condenser protection grills (opCg)
aCCeSSorieS (kit) › gateway for loN (EkloNpg) › gateway for bACNET (EkbNpg) › Address card (EkACpg) › Remote user interface (EkRUpg)
30
ewyQ130,150Dayn
31
Heating & CoolingCapacity class 080 100 130 150 180 210 230 250Cooling capacity nom. kw 77 100 136 145 183 211 231 252Heating capacity nom. kw 87.7 114 149 165 199 225.00 258 281Capacity steps %
0-50-100 0-25-50-75-10021/29-
43/50/57-71/79-100
0-25-50-75-10022/28-
44/50/56-72/78-100
0-25-50-75-100
Power input Cooling nom. kw 26.5 36.2 47.6 55.7 63.8 75.3 82.2 93.5Heating nom. kw 30.0 38.1 49.6 58.8 68.0 77.0 84.2 96.6
eer 2.91 2.76 2.86 2.60 2.87 2.80 2.81 2.70CoP 2.92 2.99 3.00 2.81 2.93 2.92 3.06 2.91eSeer 4.00 3.81 4.31 4.07 4.33 4.23 4.20 4.00Dimensions Unit HeightxwidthxDepth mm 2,311x2,000x2,566 2,311x2,000x2,631 2,311x2,000x3,081 2,311x2,000x4,850weight Unit kg 1,400 1,450 1,550 1,600 1,850 1,900 3,200 3,300
operation weight kg 1,415 1,465 1,567 1,619 1,875 1,927 3,239 3,342water heat exchanger
type brazed plate, one per unitnominal water flow
Cooling l/min 221 287 390 416 525 605 662 722Heating l/min 251 327 427 473 570 645 740 806
nominal water pressure drop
Cooling total kPa 36 43 38 41 44 39 38Heating total kPa 47 46 51 49 48 50 48 46
air heat exchanger type Cross fin coil/Hi-Xss tubes and poly ethylene coated waffle finsfan air flow rate nom. m³/min 780 800 860 1,290 1,600
Speed rpm 880 900 970 900Sound power level Cooling nom. dba 86 88 89 90 91Compressor type Scroll compressoroperation range water side Cooling min.~max. °CDb -10 (oPzl) ~ 25
water side Heating min.~max. °CDb 25 ~ 50air side Cooling min.~max. °CDb -15 ~ 43air side Heating min.~max. °CDb -10 ~ 21
refrigerant type r-410aControl electronic expansion valveCircuits Quantity 1 2
refrigerant circuit Charge kg 33 37 22 32 39refrigerant circuit 2 Charge kg - 22 32 39Piping connections
water heat exchanger inlet / outlet 3" oD 3"water heat exchanger drain 1/2"g
Power supply Phase / frequency / Voltage Hz / V 3~ / 50 / 400
32
water CooledDaikin offers you compact
water cooled chiller units which require only
very limited space in a machine room.
Used for commercial or industrial applications,
these chillers generate cold and hot water,
which can be used for chilling, heating,
or even both at the same time.
TAblE of CoNTENTS
ewwP-kbw1n 32
ewwD-bjynn 34
1. balancing valve2. pressure gauge3. Temperature sensor4. Drain valve5. Shut-off valve6. fill valve7. filter8. Drain9. Safety valve10. pressure port11. pump12. flow switch13. pressure regulating valve14. bypass valve
p I p I N g D I A g R A m f o R C o m f o R T C o o l I N g A p p l I C AT I o N
Chillers
Evap
orat
or
expan-sion
vessel
buffer tank
Cond
ense
r
expan-sion
vessel
buffer- tank
To fan coil units
To fan coil units
34
ewwP-kBw1n water cooled chiller
s c r o l l
StrengtHS › Standard integrated: main switch, water
filter, flow switch, air purge, pressure ports › Daikin scroll compressor › optimised for use with R-407C › Electronic DDC controller › low operating sound level › low energy consumption › Extension possible up to 72hp › Compact dimensions and low refrigerant volume › Easy installation and maintenance › Stainless steel plate heat exchanger › Remote cooling or heating selection › Water/water heat pump, with water reversibility › Compatible with hydraulic module › µC² SE CoNTRollER › pCo3 controller for assembly of 2 or 3 modules
for Single moDUle UnitS › Standard main isolator switch › basic hydraulic components
for kA-series included with the unit as a kit: flow switch, air purge, filter + shut-off valves for both condenser and evaporator
oPtionS (faCtory moUnteD) › Chilled water temperature down
to - 5°C (opZh) or -10°C (opZl)
aCCeSSorieS (kit) › Compressor soundproof material (-3dbA) › hydraulic module
(see page EhmC-page in this catalogue) › bmS gateway (moDbUS/J-
bUS / bACNET protocol) › Remote user interface
Control › microprocessor control › Water inlet
temperature control › Cold water or hot water regulation
aVailable inPUtS / oUtPUtSinput › Remote oN / off › pump contact › Cool/heat selection
output › Compressor operation › Summary alarm › pump relay contact
µC2 Se
35
ewwP014-035kbw1n ewwP090-130kbw1n ewwP145-195kbw1n
Heating only & Cooling onlyCapacity class 014 022 028 035 045 055 065 090 100 110 120 130 145 155 165 175 185 195Cooling capacity nom. kw 13.0 21.5 28.0 32.5 43.0 56.0 65.0 86.0 99.0 112 121 130 142 155 168 177 186 195 Heating capacity nom. kw 16.6 27.3 35.4 41.2 54.8 71.4 82.7 110 126 143 154 165 181 198 214 226 237 248Capacity steps number 1 2 4 6Power input Cooling nom. kw 3.61 5.79 7.48 8.75 11.80 15.50 17.60 23.6 27.3 31.0 33.1 35.2 39.1 42.8 46.5 48.6 50.7 52.8eer 3.60 3.71 3.74 3.71 3.64 3.61 3.69 3.64 3.63 3.61 3.66 3.69 3.63 3.62 3.61 3.64 3.67 3.69Dimensions Unit HeightxwidthxDepth mm 600x600x600 600x600x1,200 1,200x600x1,200 1,800x600x1,200weight Unit kg 118 155 165 172 300 320 334 600 620 640 654 668 920 940 960 974 988 1.002
operation weight kg -water heat exchanger - evaporator
type brazed plateminimum water volume in the system l 62 103 134 155 205 268 311 205 268 311 205 268 311water flow rate min. l/min 19 31 40 47 62 80 93 123 142 161 173 186 204 222 241 254 267 280
nom. l/min 37 62 80 93 123 161 186 247 284 321 347 373 407 444 482 507 533 559max. l/min 75 123 161 186 247 321 373 493 568 642 694 745 814 889 963 1,015 1,066 1,118
water heat exchanger - condenser
type brazed platewater flow rate min. l/min 24 39 51 59 79 102 118 157 181 205 221 237 260 283 307 323 339 355
nom. l/min 48 78 102 118 157 205 237 314 362 410 442 474 519 567 614 647 679 711max. l/min 95 157 203 237 314 410 474 629 724 819 883 948 1,038 1,133 1,229 1,293 1,357 1,422
Sound power level Cooling nom. dba 64 71 67 74 71 75 77 73 76 78 79Compressor type Hermetically sealed scroll compressoroperation range evaporator Cooling min.~max. °CDb -10 (oPzl) ~ 25
Condenser Cooling min.~max. °CDb 20 ~ 55refrigerant type r-407C
Control thermostatic expansion valveCircuits Quantity 1 2 4 6
refrigerant circuit Charge kg 1.2 2 2.5 3.1 4.6 5.6 9.2 10.2 11.2 13.8 14.8 15.8 16.8Piping connections
evaporator water inlet/outlet fbSP 25mm fbSP 40mm 2 x 2 x fbSP 38mm 3 x 2 x fbSP 38mmevaporator water drain field installationCondenser water inlet/outlet fbSP 25mm fbSP 40mm 2 x 2 x fbSP 38mm 3 x 2 x fbSP 38mmCondenser water drain field installation
Power supply Phase / frequency / Voltage Hz / V 3n~ / 50 / 400
36
ewwd-BjYnn water cooled chiller
Digital Controller
StrengtHS › Cooling range: 369–1,050kW › Super high efficiency: EER up to
5.8 ; A class energy label › Very high EER values at part loads
condition (ESEER up to 7.4) › 1 and 2 stepless single-screw compressors › optimised for use with R-134a › flooded evaporator › Expansion valve with liquid level control › All models are pED pressure vessel approved
StanDarD aVailable › main switch › gauges › Electronic expansion valve
oPtionS (faCtory moUnteD) › glycol application › Suction stop valve › A / V meter › Soft starter › Cu / Ni heat exchanger
aCCeSSorieS › Communication cards
(EkAC200J – EkACbAC – EkACloN) › Remote user interface (EkRUpCk) › buffer tanks (EkbT500N - EkbTC10N
- EkbT500C - EkbTC500C) › Daikin serial sequencing panel (EkDSSp) › modem (EkmoDEm – EkgSmoD) › Converter RS485 to RS232 (EkCoN)
or to USb (EkCoNUSb)
s c r e w
37
ewwDC11bjynn
Cooling onlyCapacity class 380 460 550 750 850 900 C10 C11Cooling capacity nom. kw 369 445 521 734 816 895 976 1,050 Capacity steps % stepless 25 - 100 Stepless 12.5 - 100Power input Cooling nom. kw 65 77.9 90 129 142 155 167 180 eer 5.68 5.71 5.79 5.65 5.71 5.77 5.81 5.83eSeer 6.44 6.47 6.56 7.16 7.23 7.32 7.37 7.40Dimensions Unit HeightxwidthxDepth mm 2,250x3,625x1,551 2,250x3,860x1,551 2,300x4,145x1,743 2,300x4,145x1,808 2,300x4,145x1,910weight Unit kg 3,089 3,370 3,603 5,546 5,636 6,007 6,448 6,598
operation weight kg 3,250 3,588 3,870 5,911 6,045 6,460 6,972 7,163water heat exchanger - evaporator
type flooded shell and tubeminimum water volume in the system l 78 107 134 184 210 281 302water flow rate min. l/min 565 615 776 932 1,216 1,209 1,382 1,632
nom. l/min 1,058 1,276 1,494 2,104 2,339 2,566 2,798 3,010max. l/min 1,788 1,945 2,455 2,946 3,846 3,825 4,370 5,162
nominal water pressure drop
Cooling Heat exchanger
kPa 35 43 37 51 37 45 41 34
water heat exchanger - condenser
minimum water volume in the system l 83 111 133 181 199 243 263water flow rate min. l/min 665 948 1,086 1,478 1,703 1,904 1,924 2,146
nom. l/min 1,244 1,499 1,752 2,474 2,746 3,010 3,277 3,526max. l/min 2,103 2,998 3,435 4,675 5,386 6,020 6,085 6,786
nominal water pressure drop
Heating kPa 35 25 26 28 26 25 29 27
water heat exchanger - heat recovery condenser type Shell and tubeSound pressure level
Cooling nom. dba 78 79 80 81 81.5 82 82.5 83
Compressor type Semi-hermetic single screw compressoroperation range evaporator Cooling min.~max. °CDb -8 ~ 15
Condenser Cooling min.~max. °CDb 21 ~ 50refrigerant type r-134a
Charge kg 130 165 180 200 215 230 274 290Control electronic expansion valveCircuits Quantity 1
Piping connections evaporator water drain 1/2" gasPower supply Phase / frequency / Voltage Hz / V 3~ / 50 / 400
38
Condenserless ChillerDaikin offers you flexible and compact chillers
with remote condenser, which can be used to satisfy
applications with special requirements in the field
of available space, sound level or extreme operating
conditions. in these exceptional cases, remote
condenser solutions can be preferred over standard
air cooled or water cooled solutions.
TAblE of CoNTENTS
ewlP-kbw1n 38
1. Temperature sensor2. filter3. Shut-off valve4. pump5. pressure port6. flow switch7. Drain8. pressure gauge9. Water flow adjusting valve10. Drain valve11. fill valve12. Safety valve
pIpINg DIAgRAm foR ComfoRT CoolINg ApplICATIoN
7 6 5 4 5
3 2
1
5 98 103 11
12
7
1
ChillersGas
Liquid
Evap
orat
or
buffer
tank
To fan coil
units
To condenser
expan-
sion
vessel
40
ewlP-kBw1n water cooled condenserless chiller
s c r o l l
StrengtHS › Daikin scroll compressor › optimised for use with R-407C › Electronic DDC controller › low operating sound level › low energy consumption › Compact dimensions and low refrigerant volume › Easy installation and maintenance › Stainless steel plate heat exchanger › Compatible with hydraulic module › for EWlp012-065kbW1N following components
are standard included: main switch, pressure ports, flow switch, filter, shut-off valves and air purge
› µC² SE controller
oPtionS (faCtory moUnteD) › Chilled water temperature
down to - 5°C (Zh) or -10°C (Zl)
aCCeSSorieS (kit) › hydraulic module (see EhmC-page in this catalogue) › low noise operation EUW*5kZW1 (EklS1) › low noise operation EUW*8-24kZW1 (EklS2) › Address card for connection to bmS or
remote user interface (EkRUmCA) › Remote installed user interface (EkAC10C)
Control › microprocessor control › Water inlet temperature control
aVailable inPUtS / oUtPUtSinput › Remote oN / off › pump contact
output › Compressor operation › Summary alarm › pump relay contact
µC 2 Se
ewlP012-030kbw1n
Cooling onlyCaPaCity ClaSS 012 020 026 030 040 055 065
Capacity Cooling kw 12.1 20.0 26.8 31.2 40.0 53.7 62.4Power input Cooling kw 4.2 6.6 8.5 10.1 13.4 17.8 20.3Capacity Steps 1 2eer 2.88 3.03 3.15 3.09 2.99 3.02 3.07Dimensions Height x width x Depth mm 600 x 600 x 600 600 x 600 x 1,200weight machine weight kg 108 141 147 151 252 265 274water Heat exchanger evaporator
type brased plateminimum water volume in the system l 62 103 134 155 205 268 311water flow rate
min l/min 17 29 38 45 57 77 89nominal l/min 35 57 77 89 115 154 179max l/min 69 115 153 179 229 307 358
Compressor type Hermetically sealed scroll compressormodel Quantity 1 2
Sound Power Cooling dba 64 71 67 74operation range evaporator min~max °CDb -10(oPzl) ~ 20
Condensing temperature min~max °CDb 25 ~ 60refrigerant circuit refrigerant type r-407C
no of circuits 1 2refrigerant control thermostatic expansion valve
Power Supply 3n~/400V/50HzPiping connections evaporator water inlet/outlet mm fbSP 25 fbSP 40
evaporator water drain field installationliquid line connection mm 9.52 flare 12.7 flare 2x12.7 flareDischarge line connection mm 12.7 flare 19.1 flare 2x19.1 flare
41
42
dicn
Daikin chillers can be equipped with Daikin Integrated
Chiller Network (DICN) which allows the simultaneous
operation of up to 4 chillers as if they were a single
unit, in order to deliver the required cooling capacity.
This results in precise and efficient capacity control
and is also useful for back up purposes, ensuring that
the necessary amount of cooling is available and
guaranteeing reliable operation of the chiller plant.
This function enables a Daikin 2mW chiller plant to be
operated via a single controller. please note that DICN is
only possible within the same series.
aPPliCable SerieS: › EWAq080-260DAyN (R-410A) › EWyq080-250DAyN (R-410A)
Daikin integrated Chiller network
43
eHMc, ekBt Hydraulic module, buffer tank
mH2O
55
50
45
40
35
30
25
20
15
10
5
00 20 40 60 80 100 120 140 160 180 200 220 240 260 WF (l/min)
Water flow
PUmP CHaraCteriStiCS
StrengtHS › 100l buffer tank › freeze-up protection (heater tape) › Single pump › 12l expansion vessel › Standard dual pressure ports
legenDS
Pump characteristics
1. EhmC30AV10802. EhmC10AV1080 &
EhmC15AV10803. EhmC30AV10104. EhmC10AV1010 &
EhmC15AV1010
Hydraulic module + filter pressures losses
5. EhmC15/30AV1010 & EhmC15/30AV1080
6. EhmC10AV1010 & EhmC10AV1080
Hydraulic moduleeHmC-aV
10 15 30
1010 1080 1010 1080 1010 1080
nominal flow l/min 62 88 187nominal static height mH2o 17 34 15 27 10 27nominal input w 630 1,050 650 1,070 1,070 2,090Dimensions (HxwxD) mm 1,284x635x688machine weight kg 99 101 102 104 105 111Sound power dba 63Sound pressure dba 52Power supply V1 1~/230V/50Hzoperation range water side °C -10°C ~ 55°C
air side °CDb -10°C ~ 43°CPiping connections water inlet/outlet 1" bSPf 2" bSPf 2-1/2" bSPf
Drain connection 1/2"
buffer tankMODEL Description Volume Dimensions Unit weight
ekbt buffer tank with cabinet 200l 1,284x637x754 86,5
ekbt500n buffer tank 500l 710x1,670 70
ekbtC10n buffer tank 1,000l 860x2,020 100
ekbt500C buffer tank with cabinet 500l 1,200x1,200x1,950 160
ekbtC10C buffer tank with cabinet 1,000l 1,200x1,450x1,950 185
44
fan Coil Unitsfan Coil Units are a highly efficient means of turning
a water chiller, heat pump or hot water boiler into an efficient,
quiet air conditioning system. these units are an effective
solution to provide a comfortable environment for both
commercial and residential applications.
Daikin offers a wide range of fan Coil Units for both concealed
and exposed applications.three models are available in flexible
application. the only moving part in the units is the fan,
making them ideal for use in offices, hotels and at home.the
goal is to obtain the right solution, both technically
and aesthetically.
fan Coil Unit - aCCeSSorieS 44
fan Coil Unit - Control 46
fwV-Dt/Df 48
fwl-Dt/Df 49
fwm-Dt/Df 50
fwD-at/af 51
fwt-bt 52
fwb-bt 53
fwb-jt/jf 54
fwC -bt/bf 55
fwf-bt/bf 56
TAblE of CoNTENTS
45
02
02 03 04 06 07 08
05 06 07 08 09 1110
02 03 04 06 10
03 04 05 06 08 09 10 11
02 03 05
02 03 04 05 06
03 04
02 03
06 07 08 09
06 07 08
0706 09
06 07 08 09
02 03 06 08 10
01 02 03 04 06 08 10
02 03 06 08 10
02 03 0406 08
02 03 06 08 10
01 02
02
03
03
03
03
04
07
07
07
02
02
03
06
06
06
01
02
02
04
04
04 06 08 10 12 16 18
08 10 12 16 18
03
03
03
08 10 12
04
04
04
1816
02
05
05
05
03
03
04
04
04
0604
06
08
08
09
04
0604
06
06
06
08
08
09
09
10
06
08
08
08
08
10
10
10
10
10
10
08 10
10
12
0607
050910
08
09
04 06
08
04
02
04
04
10
04
1002
18
16
measuring conditions (at nominal air flow and ESp) : CoolINg • air temperature entering the unit: 27°C/19°C • water temperature entering the unit 7°C • leaving the unit 12°C hEATINg • room air temperature 20°C • for 2 pipe units : water temperature entering 50°C - water flow rate same as for the cooling test • for 4 pipe units : water temperature entering 70°C - water temperature leaving 60°C.* 4-pipe= 2-pipe + option additional heat exchanger
pRoDUCT poRTfolIo
0202
01
01
01
01
01
01
07 08
02 07
10
03
08
100604
06
06
02
0403
02 08
Reference
FWT-
BT
2-pipecooling
heating
FWC-
BT/B
F 2-pipecooling
heating
4-pipecooling
heating
FWF-
BT/B
F 2-pipecooling
heating
4-pipecooling
heating
FWV-
DT/
DF 2-pipe
cooling
heating
4-pipecooling
heating
FWL-
DT/
DF 2-pipe
cooling
heating
4-pipecooling
heating
FWM
-DT/
DF 2-pipe
cooling
heating
4-pipecooling
heating
FWB
-BT
2-pipecooling
heating
4-pipe*cooling
heating
FWD
-AT/
AF 2-pipe
cooling
heating
4-pipecooling
heating
FWB
-JT/
JF
2-pipecooling
heating
4-pipecooling
heating (4-pipe)
05
05
02 0304 05
03 0402 05
01
04
1 2 3 4 5 6 7 8 9 10 11 12 16 18 20 22kW
01
01
46
fAn coil unit - AcceSSorieS
tyPefwt fwC-bt/bf fwf-bt/bf
Description
Standard wired remote control merCa - -
Simplified wired remote control SrC-Cob - -
Simplified wired remote control SrC-HPb - -
wireless control for cooling only wrC-Cob - -
wireless control for heat pump wrC-HPb - -
Decoration Panel (ral 9010 - grey sealings) 4-way blow - - byfQ60b
Decoration Panel - Standard (ral 9010 - grey sealings) round flow
- byCQ140Cw1
Decoration Panel - white (ral 9010 - white sealings) round flow
- byCQ140Cw1w
Sealing member of air dis-charge outlet - kDbHQ55C140 kDbH44ba60
Panel spacer - - kDbQ44b60
long-life filter - kafP551k160 kafQ441ba60
fresh air intake kit - Direct installation type - - kDDQ44Xa60
fresh air intake kit (20% fresh air) - Direct installation type -
kDDQ55C140-1 (*20) /
kDDQ55C140-2 (*20)
-
remote controller - wireless - H/P - brC7f532f (*18) brC7e530 (*18)
remote controller - wireless - C/o - brC7f533f (*18) brC7e531 (*18)
remote controller - wired - brC315D7 (*4)
Central remote controller - DCS302Ca51 (*5)
electrical box with earth terminal (3 blocks) - kjb311a
Unified on/off controller - DCS301ba51 (*9)
electrical box with earth terminal (2 blocks) - kjb212a
Schedule timer - DSt301ba51 (*6)(*9)DSt301ba51
(*6)(*9)wiring adapter for electrical appendices (1) -
krP2a52 (*7) (*12)
krP2a52 (*9) (*12)
wiring adapter for electrical appendices (2) -
krP4aa53 (*7) (*12)
krP4aa53 (*9) (*12)
installation box for adapter PCb - krP1H98 (*13) krP1ba101 (*17)
remote sensor - krCS01-4 krCS01-1
intelligent touch controller - DCS601C51C(*6) (*11)DCS601C51C (*6)
(*11)
electrical installation box - kjb411a
optional PCb for moD-bus connection -
ekfCmbCb7 (*8) (*12)
ekfCmbCb7 (*8) (*12)
2-way valve - on/off - ekmV2C09b7 (*8) (*10) (*15)ekmV2C09b7 (*8) (*10) (*16)
3-way valve - on/off - ekmV3C09b7 (*8) (*10) (*15)ekmV3C09b7 (*8) (*10) (*16)
Valve control PCb - ekrP1C11
remote “on/off” and “forced off” kit - ekroroa (*17)
type: fwm-Dt/Df, fwl-Dt/Df, fwV-Dt/Df 1 2 3 4 6 8 10 fwV fwl fwMDescriptionadditional single row heat exchanger eSrH02a6 eSrH03a6 eSrH06a6 eSrH10a6 x x x
electric heater eeH01a6 eeH02a6 eeH03a6 eeH06a6 eeH10a6 x x x2-pipe 3-way valve e2mV03a6 e2mV06a6 e2mV10a6 x x x4-pipe 3-way valve e4mV03a6 e4mV06a6 e4mV10a6 x x xfan stop thermostat yfSta6 x x xair intake & discharge grille eaiDf02a6 eaiDf03a6 eaiDf06a6 eaiDf10a6 - - xSupporting feet eSfV06a6 eSfV10a6 x - xSupporting feet + grille eSfVg2a6 eSfVg3a6 eSfVg6a6 eSfVg10a6 x - -fresh air intake efa2a6 efa3a6 efa6a6 efa10a6 x - -rear panel erPV2a6 erPV3a6 erPV6a6 erPV10a6 x x -Control electromechanical eCfwmb6 x x xelectronic controller fweC1a, fweC2a, fweC3a x x xmaster slave option ePimSb6 x x xVertical drainpan eDPVa6 x x xHorizontal drainpan eDPHa6 - x xon board installation kit fweCka x x -temperature sensor kit fwtSka x x xrelative humidity sensor kit fwHSka x x xon board fCU controller installation kit fweCka x x -
1. requires electronic controller2. for fwD 12,16,18at/af only motor valve (piping not included)3. water probe included4. optional, electrical installation box with earth terminal kjb212a is required, if controller wires need to be installed
in the wall.5. requires electrical installation box with earth terminal kjb311a.6. requires electrical installation box kjb411a.7. requires installation box krP1H98. (fwC)8. requires installation box krP1ba101 (fwf)9. requires electrical installation box with earth terminal kjb212a, if built in the wall.10. requires valve control PCb ekrP1C1111. i-touch:
• not allowed to