64
Catalogue Applied systems CLIMATE COMFORT All Seasons Heating Air Conditioning Applied Systems Refrigeration
Transcript
  • CatalogueApplied systems

    Climate Comfortall Seasons

    Heating

    air Conditioning

    Applied Systems

    refrigeration

  • 5

    table of ContentsProDUCt Portfolio - air CooleD 04

    ProDUCt Portfolio - water CooleD 04

    oPtionS Portfolio 04

    aCCeSSorieS Portfolio 06

    aboUt Daikin 08

    enVironmental awareneSS 09

    Heat reCoVery 10

    reliable & effiCient 12

    No matter how large your premises and whatever your air conditioning needs, there is a Daikin chilled water system

    to suit your requirements. It is a system that has proved its worth in a multiplicity of situations - from industrial sites to

    retail warehouses, hotels and department stores.

    The careful development of closely matched compressor/refrigerant combinations, has enabled Daikin to produce

    complete ranges of water chillers — genuinely optimised for use with R-134a, R-407C and R-410A refrigerants.

    Daikin chillers offer the ultimate in flexibility and control — a reflection of the advanced technology inherent within

    them. Unique in their precision, power, low operating noise, easy maintenance and low running costs, Daikin chillers

    represent the sure and safe route to an indoor environment that is comfortable, clean and consistent.

    As a manufacturer that makes its own refrigerant and compressors, Daikin has total control at the production stage.

    Daikin also offers a complete range of air handling units to meet modern day requirements for better indoor air quality

    and increased insulation standards.

    It is this unique combination of advanced technology, experience and reliability that makes Daikin the obvious choice

    and long term solution for the professional.

    air CooleD 14

    water CooleD 30

    ConDenSerleSS CHiller 36

    D.i.C.n. 40

    HyDraUliC moDUle & bUffer tank 41

    fan Coil UnitS 42

    air HanDling UnitS 58

    meaSUring ConDitionS 62

  • 6

    type Compr. refr. mode reference Packshot 0 17.5 200 500 1,000 2,000

    air

    cool

    ed

    Swing

    r-410a

    ewaQ005-007aCV3

    SCrollewaQ009-011aCV3

    ewaQ009-013aCw1

    Swing

    r-410a

    ewyQ005-007aCV3

    SCrollewyQ009-011aCV3

    ewyQ009-013aCw1

    SCroll

    r-407C

    eUwaC5-10fbzw1

    eUwa*5-24kbzw1

    eUwy*5-24kbzw1

    r-410a

    ewaQ080-260Dayn

    ewyQ080-250Dayn

    = Cooling only

    = heating only

    = heat pump

    = heating

    = Cooling

    kw

    236

    254

    209

    80 105

    152

    182

    131

    2 2 2 2 21 1 2

    080

    100

    130

    150

    180

    210

    240

    260

    18.4

    11.6

    23.8

    5 8 10

    1 1 1

    509.1 17.1

    21 25 34.2

    4037 46 54272418

    .5

    11.9

    5 8 10 12 16

    20

    24

    2221111

    1 1 1 1 2 2 2

    11.3

    19.7

    22.5

    26.5

    34.6

    46.6

    55.3

    8 10 12 16 20 245

    1 1 1 1 2 2 2

    2 2 2 21 1 2 2

    2 2 2 2 2 21 1

    080

    100

    130

    150

    180

    210

    230

    165

    199

    225

    258

    87.7

    114

    281

    149 2

    50

    77 145

    183

    231

    252

    100

    136

    211

    7.1 115.2 6

    005

    006

    007

    011

    1 1 1

    8.500

    9

    1

    9.501

    0

    1 1

    13.2

    11.0

    013

    1

    900

    9

    1

    011

    1

    11

    5.65

    7.75

    10 11.5

    13

    14

    6.35

    1

    1

    1

    12.5

    1

    1 1 1 1 1

    7.1 115.2 6

    005

    006

    007

    011

    1 1 1

    8.500

    9

    1

    9.501

    0

    1 1

    13.2

    0131

    900

    91

    1101

    11

    type Compr. refr mode reference Products

    integrated Hydronics noise & Head Pressure control lwe electrical refrigerant condenser

    Single pump contact

    twin pump contact Single pump twin pump High eSP pump buff er tank low noise inverter fans High eSP fans High glycol low glycol

    evaporator heater tape

    mainswitch a / V meter

    Dual pressure relief valve

    Suction stop valve Coil guards

    oPSC oPtC oPSP oPtP oPHP oPbt oPln oPif oPHf oPzH oPzl oP10 oP52 oP57 oP03 oP12 oPCg

    air

    Cool

    ed

    Swing r-410aewaQ-aCV3 005-006-007 StD StDewyQ-aCV3 005-006-007 StD StD

    SCroll

    r-410a

    ewaQ-aCV3 009-010-011 StD StDewaQ-aCw1 009-011-013 StD StDewyQ-aCV3 009-010-011 StD StDewyQ-aCw1 009-011-013 StD StD

    r-407C

    eUwaC-fbzw1 5-8-10 • •eUwan-kbzw1 5-8-10-12-16-20-24 • • • •eUwaP-kbzw1 5-8-10-12-16-20-24 • • • • •eUwab-kbzw1 5-8-10-12-16-20-24 • StD • • • •eUwyn-kbzw1 5-8-10-12-16-20-24 • • • •eUwyP-kbzw1 5-8-10-12-16-20-24 • • • • •eUwyb-kbzw1 5-8-10-12-16-20-24 • StD • • • •

    r-410aewaQ-Daynn 080-100-130-150-180-210-240-260 • • • • • • • •(2) • • StD • • •(s) •ewyQ-Daynn 080-100-130-150-180-210-240-260 • • • • • • • •(2) • • StD • • •(s) •

    wat

    er

    Cool

    ed

    SCroll r-407C ewwP-kbw1n 014-022-028-035-045-055-065 • •

    Cond

    en-

    serle

    ss

    chill

    er

    SCroll r-407C ewlP-kbw1n 012-020-026-030-040-055-065 • •

    oPtionS Portfolio

    (s) op12 & op03 need to be added to meet Swedish national law 1992: 16

    (1) Impossible option combination: opZh+opZl

    (2) Not available with option oplN

    type Compr. refr. mode reference Packshot 0 17.5 200 500 1,000 2,000 9,000

    wat

    er c

    oole

    d

    SCroll r-407CewwP014-065kbw1newwP090-195kbw1n

    Cond

    ense

    rless

    ch

    iller

    SCroll r-407C ewlP012-65kbw1n

    kw

    = Cooling only

    = heating only

    = heating

    = Cooling

    54.8

    41.2

    27.3

    35.4

    16.6

    82.7

    110

    126

    143

    71.4

    165

    181

    198

    214

    226

    237

    248

    014

    022

    028

    035

    045

    055

    065

    090

    110

    120

    130

    145

    155

    165

    175

    185

    195

    100

    8613 21 28 32 43 56 65 195

    99 112

    121

    130

    142

    155

    168

    177

    186

    666666444422211 411

    211 11 2 2 4 4 4 4 6 6 6 6 6 6

    154

    4

    012

    020

    026

    030

    045

    055

    065

    1 1 1 1 2 2 2

    Product Portfolio Air cooled

    Product Portfolio wAter cooled

    oPtion Portfolio

  • 7

    type Compr. refr. mode reference Packshot 0 17.5 200 500 1,000 2,000

    air

    cool

    ed

    Swing

    r-410a

    ewaQ005-007aCV3

    SCrollewaQ009-011aCV3

    ewaQ009-013aCw1

    Swing

    r-410a

    ewyQ005-007aCV3

    SCrollewyQ009-011aCV3

    ewyQ009-013aCw1

    SCroll

    r-407C

    eUwaC5-10fbzw1

    eUwa*5-24kbzw1

    eUwy*5-24kbzw1

    r-410a

    ewaQ080-260Dayn

    ewyQ080-250Dayn

    SCrew r-134a

    ewaD100-410e-SS

    ewaD100-400e-Sl

    ewaD390-580D-SS

    ewaD180-530D-Sl

    ewaD180-530D-Sr

    ewaD210-490D-SX

    ewaD250-620D-XS

    ewaD240-600D-Xr

    ewaD200-590D-HS

    ewyD250-580bzSS

    ewyD250-570bzSl

    ewaD330-520bzSS/Sl

    ewaD330-520bzXS/Xl/Xr

    ewaD670-C18CzXS/Xl

    ewaD640-C17CzXr

    ewaD650-C20C-SS/Sl

    ewaD620-C19C-Sr

    ewaD760-C22C-XS/Xl

    ewaD740-C22C-Xr

    ewaD820-C16C-PS/Pl

    ewaD810-C16C-Pr

    Cond

    ensi

    ng

    units SCrew r-134a

    eraD120-490e-SS

    eraD120-460e-Sl

    = Cooling only

    = heating only

    = heat pump

    = heating

    = Cooling

    CHillerPortfolio

    Portfolio air CooleD UnitS

    kw

    236

    254

    256

    252

    243

    249

    307

    306

    295

    296

    360

    370

    352

    345

    413

    435

    409

    488

    462

    398

    209

    214

    219

    209

    209

    80 105

    101

    97.9

    152

    163

    165

    159

    157

    182

    183

    196

    187

    177

    131

    138

    144

    137

    134

    121

    121

    116

    116

    2

    1

    1

    1

    1

    2

    1

    1

    1

    1

    2

    1

    1

    1

    1

    2 2

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1 1

    1

    1

    2

    1

    1

    1

    1

    1

    1

    1

    1

    080

    100

    100

    100

    130

    140

    140

    140

    130

    120

    120

    120

    120

    150

    160

    170

    160

    160

    180

    180

    200

    190

    180

    210

    210

    220

    210

    210

    240

    260

    260

    250

    240

    250

    310

    310

    300

    300

    360

    370

    350

    350

    410

    440

    410

    490

    460

    400

    18.4

    11.6

    23.8

    5 8 10

    1 1 1

    509.1 17.1

    21 25 34.2

    4037 46 54272418

    .5

    11.9

    5 8 10 12 16

    20

    24

    2221111

    1 1 1 1 2 2 2

    11.3

    19.7

    22.5

    26.5

    34.6

    46.6

    55.3

    8 10 12 16 20 245

    1 1 1 1 2 2 2

    2 2 2 21 1 2 2

    2 2 2 2 2 21 1

    080

    100

    130

    150

    180

    210

    230

    165

    199

    225

    258

    87.7

    114

    281

    149 2

    50

    77 145

    183

    231

    252

    100

    136

    211

    7.1 115.2 6

    005

    006

    007

    011

    1 1 1

    8.500

    9

    1

    9.501

    0

    1 1

    13.2

    11.0

    013

    1

    900

    9

    1

    011

    1

    11

    5.65

    7.75

    10 11.5

    13

    14

    6.35

    1

    1

    1

    12.5

    1

    1 1 1 1 1

    7.1 115.2 6

    005

    006

    007

    011

    1 1 1

    8.500

    9

    1

    9.501

    0

    1 1

    13.2

    0131

    900

    91

    1101

    11

    329

    358

    395

    423

    515

    459

    488

    330

    360

    400

    420

    460

    490

    520

    2222222

    329

    358

    395

    423

    515

    459

    488

    330

    360

    400

    420

    460

    490

    520

    2222222

    389

    436

    466

    502

    532

    556

    578

    390

    440

    470

    510

    530

    560

    580

    2222222

    225

    261

    275

    321

    370

    404

    440

    477

    505

    533

    230

    260

    280

    320

    370

    400

    440

    480

    510

    530

    184

    180

    2

    198

    200

    2 2

    245

    250

    2 2 2

    298

    300

    2 2 2 2 2 2 2 2

    203

    247

    243

    195

    231

    275

    272

    208

    253

    265

    302

    296

    234

    271

    327

    322

    256

    286

    351

    345

    274

    299

    376

    370

    289

    309

    401

    455

    306

    370

    469

    512

    336

    413

    524

    561

    381

    451

    575

    600

    415

    448

    478

    514

    547

    587

    492

    622

    210

    250

    240

    200

    230

    280

    270

    210

    250

    270

    300

    300

    230

    270

    330

    320

    260

    290

    350

    350

    270

    300

    380

    370

    290

    310

    400

    460

    310

    370

    470

    510

    340

    410

    520

    560

    380

    450

    580

    600

    420

    450

    480

    510

    550

    590

    490

    620

    2

    2

    2

    2

    2

    2 2 2 2 2 2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2 2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    190

    177

    219

    238

    252

    278

    312

    366

    404

    440

    477

    505

    533

    220

    190

    180

    240

    250

    280

    310

    370

    400

    440

    480

    510

    530

    22 2 2 2 2 2 2 2 2 2 2 2

    324

    324

    349

    443

    297

    297

    349

    379

    379

    410

    410

    443

    463

    463

    475

    475

    530

    530

    558

    558

    615

    615

    270

    270

    333

    333

    250

    250

    270

    270

    290

    290

    320

    320

    340

    330

    370

    360

    380

    370

    410

    400

    440

    430

    460

    450

    510

    490

    520

    510

    580

    570

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    3

    3

    3

    3

    3

    3

    3

    3

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    3

    3

    3

    3

    3

    3

    3

    3

    2

    2

    2

    2

    2

    2

    2

    2

    254

    248

    273

    266

    292

    291

    324

    316

    339

    331

    365

    355

    382

    372

    413

    403

    436

    425

    457

    448

    505

    493

    522

    510

    583

    567

    672

    635

    647

    619

    715

    756

    736

    821

    809

    875

    956

    1,053

    1,132

    1,251

    1,359

    1,439

    1,521

    890

    975

    1,074

    1,158

    1,279

    1,390

    1,474

    1,562

    811

    866

    974

    1,041

    1,268

    1,247

    1,302

    1,367

    1,468

    1,550

    1,639

    1,722

    1,813

    1,854

    1,902

    1,959

    830

    889

    1,001

    1,280

    1,349

    1,525

    1,409

    1,596

    1,685

    1,768

    1,858

    1,901

    1,953

    2,008

    789

    876

    1,020

    1,112

    1,270

    1,321

    1,418

    1,556

    1,623

    1,714

    1,795

    1,833

    922

    744

    832

    912

    967

    1,064

    1,152

    1,319

    1,418

    1,419

    1,538

    1,622

    1,714

    1,802

    1,875

    1,922

    738

    700

    832

    789

    1,236

    1,235

    1,170

    1,037

    976

    902

    852

    1,709

    1,622

    1,631

    1,095

    1,031

    1,450

    1,443

    1,308

    1,332

    1,545

    1,545

    1,802

    1,712

    670

    640

    740

    700

    830

    790

    900

    850

    C10

    980

    C11

    C10

    C12

    C12

    C11

    C14

    C14

    C13

    C13

    C15

    C15

    C17

    C16

    C16

    C18

    C17

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    22

    2

    2

    2

    2

    2

    2

    33

    3

    3

    3

    760

    830

    890

    990

    C10

    C11

    C12

    C13

    H14

    H15

    C16

    C17

    C18

    C19

    C20

    C21

    C22

    22222 3 3 3 3 3 3322222

    740

    820

    810

    880

    960

    C10

    C11

    C13

    C14

    C15

    C16

    810

    890

    870

    980

    970

    C11

    C10

    C12

    C11

    C13

    C12

    C14

    C15

    C16

    C13

    H14

    H15

    C16

    C17

    C18

    C19

    C20

    C21

    C22

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2 2 2

    2 2 2

    2 3 2 3 3 3 3 3 3 3

    650

    740

    830

    910

    970

    C11

    C12

    C13

    H14

    C14

    C15

    C16

    C17

    C18

    C19

    C20

    2 2 2 2 2 2 2 2 23 3 3 3 3 3 3

    620

    720

    790

    880

    C10

    920

    C11

    C13

    C12

    H14

    C15

    C16

    2 2 2 2 22 2 22 3 3 3

    C18

    C19

    C20

    3 3 3

    Air cooled: Eurovent certified up to 600kWWater cooled: Eurovent certified up to 1500kWNominal cooling capacities are based on Eurovent conditions: Evaporator: 12°C/7°C — Ambient: 35°CNominal heating capacities are based on Eurovent conditions: Ambient: 7°CDb/6°CWb — Condenser: 40°C/45°C

    ECpEN11-404 • 300 • 05/11 • Copyright © DaikinThe present publication supersedes EpCEN10-404.printed on non-chlorinated paper. prepared by la movida. belgium Responsible Editor: Daikin Europe N.V.,Zandvoordestraat 300. b-8400 oostende

    type Compr. refr. mode reference Packshot 0 17.5 200 500 1,000 2,000 9,000

    wat

    er c

    oole

    d

    SCroll r-407CewwP014-065kbw1newwP090-195kbw1n

    SCrew

    r-134a

    ewwD120-560j-SS

    ewwD170-600g-SS

    ewwD190-650g-XS

    ewwD340-C18i-SS

    ewwD360-C12i-XS

    ewwD380-C11bjynn

    r-410a

    ewwQ380-C20b-SS

    ewwQ420-C21b-XS

    Centri-fUgal r-134a

    ewwD320-C10fzXS

    DwSC

    DwDC

    Cond

    ense

    rless

    chi

    ller

    SCroll r-407C ewlP012-65kbw1n

    SCrew r-134a

    ewlD110-530j-SS

    ewlD160-550g-SS

    ewlD320-C17i-SS

    Portfolio water CooleD UnitS

    kw

    = Cooling only

    = heating only

    = heating

    = Cooling

    1 1

    300

    4,50

    0

    2 2

    600

    9,00

    0

    550

    526

    2

    480

    476

    2

    420

    428

    2

    380

    381

    2

    360

    352

    2

    320

    316

    2

    280

    270

    1

    240

    244

    1

    190

    189

    1

    160

    161

    1

    110

    130

    145

    165

    195

    235

    265

    290

    310

    330

    360

    390

    430

    470

    500

    530

    128

    110

    143

    192

    164

    237

    286

    265

    307

    328

    356

    383

    429

    474

    502

    530

    2 2 2 2 2 2 2 222221111

    1,134

    C12

    2

    1,038

    C11

    2

    933

    950

    2

    976

    C10

    2

    866

    850

    2

    795

    800

    2

    720

    750

    2

    573

    600

    1

    506

    500

    1

    433

    440

    1

    362

    360

    1

    521

    369

    445

    734

    816

    895

    976

    1,05

    0

    380

    460

    550

    750

    850

    900

    C10

    C11

    11111111

    460

    333

    394

    705

    640

    538

    782

    340

    400

    460

    550

    650

    700

    800

    1,15

    5

    3

    C12

    1,20

    4

    3

    C13

    1,27

    4

    3

    C14

    1,34

    6

    3

    C15

    1,40

    1

    3

    C16

    1,45

    5

    3

    C17

    1,51

    0

    3

    C18

    1 1 1 1 2 2 2

    844

    850

    2

    910

    900

    2

    1,02

    7C1

    0

    2

    986

    950

    2

    516

    422

    801

    725

    639

    1,03

    7

    973

    1,36

    9

    1,27

    0

    1,11

    6

    1,15

    8

    1,44

    9

    1,86

    3

    1,73

    3

    1,57

    3

    2,02

    0

    2,15

    2

    2 2 2 2 2 2 2

    420

    520

    640

    730

    800

    970

    C10

    C11

    C12

    C13

    C14

    C15

    C16

    C17

    C19

    C20

    C21

    1 1 1 1 1 1 2 1 2 2

    54.8

    41.2

    27.3

    35.4

    16.6

    82.7

    110

    126

    143

    71.4

    165

    181

    198

    214

    226

    237

    248

    014

    045

    035

    022

    028

    014

    055

    065

    090

    100

    110

    022

    028

    035

    045

    055

    065

    090

    110

    120

    130

    145

    155

    165

    175

    185

    195

    100

    8613 21 28 32 43 56 65 195

    99 112

    121

    130

    142

    155

    168

    177

    186

    666666444422211 411

    211 11 2 2 4 4 4 4 6 6 6 6 6 6

    140

    121

    183

    159

    317

    342

    367

    208

    256

    285

    416

    391

    465

    513

    542

    571

    120

    140

    150

    180

    210

    250

    280

    310

    330

    360

    380

    400

    450

    500

    530

    560

    147

    216

    290

    327

    431

    505

    580

    617

    655

    1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2

    1 1 21 1 2 2 2 2

    186

    223

    227

    307

    496

    366

    408

    444

    604

    541

    190 230

    280

    320

    380

    400

    460

    500

    550

    650

    2222221111

    220

    388.4

    411

    493

    577

    660

    823

    908

    990

    1,069

    1,126

    1,203

    1,313

    460

    460

    538

    630

    757

    832

    919

    993

    1,072

    1

    1

    1 1 1 1 2 2 2 2 2 2 2

    1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

    712

    2

    264

    1

    326

    1

    354

    1

    434

    2

    482

    2

    524

    2

    585

    2

    638

    2

    204

    247

    310

    343

    410

    456

    494

    552

    610

    674

    1 21 1 1 2 2 2 2 2

    C17

    1,42

    2

    3

    C16

    1,37

    0

    3

    C15

    1,31

    9

    3

    C14

    1,26

    7

    3

    C13

    1,18

    8

    3

    C12

    1,12

    5

    3

    800

    788

    2

    850

    850

    2

    900

    919

    2

    950

    966

    2

    C11

    1,07

    8

    3

    C10

    1,03

    3

    3

    750

    730

    2

    650

    657

    2

    600

    596

    2

    500

    504

    1

    420

    428

    1

    400

    391

    1

    320

    328

    1

    521

    317

    429

    635

    856

    1,04

    8

    320

    430

    520

    640

    860

    C10

    1 1 1 2 2 2

    26.8

    12.1

    20 53.7

    31.2

    40 62.4

    012

    020

    026

    030

    045

    055

    065

    1 1 1 1 2 2 2

    464

    380

    727

    637

    562

    796

    872

    960

    1,05

    5

    1,00

    7

    1,18

    5

    1,25

    5

    1,32

    5

    1,46

    0

    1,58

    41,

    748

    1,88

    8

    2,05

    0

    2 2 1 2 2 2 2 2 2 2 2 2

    380

    460

    560

    640

    730

    800

    860

    870

    960

    C10

    C11

    C12

    C13

    C14

    C15

    C16

    C17

    C19

    C20

    1 1 1 1 1 2 2

    862

    145

    155

    165

    175

    185

    195

    154

    120

    4

    130

    201

    166

    280

    334

    253

    403

    372

    494

    448

    556

    170

    170

    210

    260

    300

    320

    380

    420

    460

    500

    600

    210

    260

    300

    320

    380

    420

    460

    500

    600

    1 1 1 1 1 2 2 2 2 2

    1,161

    1,217

    1,363

    1,427

    1,507

    1,227

    1,661

    1,730

    1,790

    Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), liquid Chilling packages (lCp) and fan coil units (fCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com

    type Compr. refr mode reference Products

    integrated Hydronics noise & Head Pressure control lwe electrical refrigerant condenser

    Single pump contact

    twin pump contact Single pump twin pump High eSP pump buff er tank low noise inverter fans High eSP fans High glycol low glycol

    evaporator heater tape

    mainswitch a / V meter

    Dual pressure relief valve

    Suction stop valve Coil guards

    oPSC oPtC oPSP oPtP oPHP oPbt oPln oPif oPHf oPzH oPzl oP10 oP52 oP57 oP03 oP12 oPCg

    air

    Cool

    ed

    Swing r-410aewaQ-aCV3 005-006-007 StD StDewyQ-aCV3 005-006-007 StD StD

    SCroll

    r-410a

    ewaQ-aCV3 009-010-011 StD StDewaQ-aCw1 009-011-013 StD StDewyQ-aCV3 009-010-011 StD StDewyQ-aCw1 009-011-013 StD StD

    r-407C

    eUwaC-fbzw1 5-8-10 • •eUwan-kbzw1 5-8-10-12-16-20-24 • • • •eUwaP-kbzw1 5-8-10-12-16-20-24 • • • • •eUwab-kbzw1 5-8-10-12-16-20-24 • StD • • • •eUwyn-kbzw1 5-8-10-12-16-20-24 • • • •eUwyP-kbzw1 5-8-10-12-16-20-24 • • • • •eUwyb-kbzw1 5-8-10-12-16-20-24 • StD • • • •

    r-410aewaQ-Daynn 080-100-130-150-180-210-240-260 • • • • • • • •(2) • • StD • • •(s) •ewyQ-Daynn 080-100-130-150-180-210-240-260 • • • • • • • •(2) • • StD • • •(s) •

    wat

    er

    Cool

    ed

    SCroll r-407C ewwP-kbw1n 014-022-028-035-045-055-065 • •

    Cond

    en-

    serle

    ss

    chill

    er

    SCroll r-407C ewlP-kbw1n 012-020-026-030-040-055-065 • •

    oPtionS Portfolio

    (s) op12 & op03 need to be added to meet Swedish national law 1992: 16

    (1) Impossible option combination: opZh+opZl

    (2) Not available with option oplN

    type Compr. refr. mode reference Packshot 0 17.5 200 500 1,000 2,000 9,000

    wat

    er c

    oole

    d

    SCroll r-407CewwP014-065kbw1newwP090-195kbw1n

    Cond

    ense

    rless

    ch

    iller

    SCroll r-407C ewlP012-65kbw1n

    kw

    = Cooling only

    = heating only

    = heating

    = Cooling

    54.8

    41.2

    27.3

    35.4

    16.6

    82.7

    110

    126

    143

    71.4

    165

    181

    198

    214

    226

    237

    248

    014

    022

    028

    035

    045

    055

    065

    090

    110

    120

    130

    145

    155

    165

    175

    185

    195

    100

    8613 21 28 32 43 56 65 195

    99 112

    121

    130

    142

    155

    168

    177

    186

    666666444422211 411

    211 11 2 2 4 4 4 4 6 6 6 6 6 6

    154

    4

    012

    020

    026

    030

    045

    055

    065

    1 1 1 1 2 2 2

  • 8

    AcceSSorieS Portfolio

    air-cooled Chillers water-cooled Chillers

    ewa/yQ009-011aCV3ewa/yQ009-013aCw1 eUwaC-fbzw1 eUwa/y*-kbzw1 ewa/yQ-Dayn ewwP-kbw1n ewlP-kbw1n ewwD~bj

    PanelsekDSSP •ekDSSP-S***ekDDSP •ekPwPro •ekPwProm •Serial Cards & Comm. ModulesekaC10C • • • •ekaCPg •ekaC200aekaC200j •ekaCbaC •ekaClon •ekaClonP •ekaCrS232 •ekaCweb •ekaCbaCmStP •ekaCbaCCertekCm200jekCmlonekCmbaCmStPekCmbaCiPLON GatewayeklonPg •Other Systems & AccessoriesekClwSekCon •ekConUSb •ekmoDem •ekgSmoD •ekrP1Hb •ekrUPCjekrUPCk •ekrUPCSekPV2j •ekPwProeXt •ekgwweb •ekgwmoDem •ekbnPg •ekbmSbnaekbmSmbaekrUmCa • • •ekrUPCekrUPg •eHmC*aV1010 • •eHmC*aV1080 • •GaugesekgaU5/8ka • (5-8)ekgaU10/12ka • (10-12)ekgaU16ka • (16)ekgaU20/24ka • (20-24)Soft starterekSS • • (014-045) • (012-030)Buff er tankekbt •Waterpipe kitekgn210 • (080-210)

    ekgn260 • (ewaQ240-260Dayn& ewyQ230-250Dayn)

    CHil

    lerS

    fan

    Co

    ilS

    aCCeSSorieS Portfolio

    type: fwm-Dt/Df, fwl-Dt/Df, fwV-Dt/Df 1 2 3 4 6 8 10 fwV fwl fwMDescriptionadditional single row heat exchanger eSrH02a6 eSrH03a6 eSrH06a6 eSrH10a6 x x xelectric heater eeH01a6 eeH02a6 eeH03a6 eeH06a6 eeH10a6 x x x2-pipe 3-way valve e2mV03a6 e2mV06a6 e2mV10a6 x x x4-pipe 3-way valve e4mV03a6 e4mV06a6 e4mV10a6 x x xfan stop thermostat yfSta6 x x xair intake & discharge grille eaiDf02a6 eaiDf03a6 eaiDf06a6 eaiDf10a6 - - xSupporting feet eSfV06a6 eSfV10a6 x - xSupporting feet + grille eSfVg2a6 eSfVg3a6 eSfVg6a6 eSfVg10a6 x - -fresh air intake efa2a6 efa3a6 efa6a6 efa10a6 x - -rear panel erPV2a6 erPV3a6 erPV6a6 erPV10a6 x x -Control electromechanical eCfwmb6 x x xelectronic controller fweC1a, fweC2a, fweC3a x x xmaster slave option ePimSb6 x x xVertical drainpan eDPVa6 x x xHorizontal drainpan eDPHa6 - x xon board installation kit fweCka x x -temperature sensor kit fwtSka x x xrelative humidity sensor kit fwHSka x x xon board fCU controller installation kit fweCka x x -

    1. requires electronic controller2. for fwD 12,16,18at/af only motor valve (piping not included)3. water probe included4. optional, electrical installation box with earth terminal kjb212a is required, if controller wires need to be installed in

    the wall.5. requires electrical installation box with earth terminal kjb311a.6. requires electrical installation box kjb411a.7. requires installation box krP1H98. (fwC)8. requires installation box krP1ba101 (fwf)9. requires electrical installation box with earth terminal kjb212a, if built in the wall.10. requires valve control PCb ekrP1C1111. i-touch:

    • not allowed to use the i-touch for an installation with both fan coils and VrV units.• Can not be used in combination with fan coil units, that use moD bus communication.• no airnet or telephone connection possible.»

    12. only 1 of these 4 options can be installed on 1 indoor unit.13. max. 1 krP1H98 box can be mounted on the unit. max. 2 PCb’s can be mounted in 1 krP1H98 box. (fwC)14. max. 2 krP1ba101 boxes can be mounted on the unit. max. 1PCb can be mounted in 1 krP1ba101 box. (fwf)

    type: fwD-at/af4 6 8 10 12 16 18

    Description

    electric heater: small(1)

    eDeH04a6 eDeHS06a6 eDeHS10a6 eDeHS12a6 eDeHS18a6

    electric heater: big eDeH04a6 eDeHb06a6 eDeHb10a6 eDeHb12a6 eDeHb18a6

    2-pipe 3-way valve(2)

    eD2mV04a6 eD2mV10a6 eD2mV12a6 eD2mV18a6

    4-pipe 3-way valve eD4mV04a6 eD4mV10a6 2xeD2mV12a6 2 x eD2mV18a6

    Vertical Drainpan eDDPV10a6 eDDPV18a6

    Horizontal Drainpan eDDPH10a6 eDDPH18a6

    fan stop thermostat yfSta6

    fresh air intake eDmfa04a6 eDmfa06a6 eDmfa10a6 eDmfa12a6 eDmfa18a6

    electronic controller (3)

    fweC1a

    fweC2a

    fweC3a

    Power interface ePib6

    master slave interface ePimSa6

    temperature sensor kit fwtSka

    relative humidity sensor kit fwHSka

    type: fwb-bt2-4 5-7 8-10

    Description

    additional heat exchanger eaH04a6 eaH07a6 eaH10a63-way valve add. h/e e2mV307a6 e2mV310a63-way valve cooling h/e factory mounted2-way valve add. h/e e2mV207a6 e2mV210a62-way valve cooling h/e factory mountedelectric Heater factory mountedfan stop thermostat yfSta6Power interface - - ePib6master slave interface ePimSb6

    electronic controllerfweC1afweC2afweC3a

    temperature sensor kit fwtSkarelative humidity sensor kit fwHSkaon board installation kit fweCka

    type: fwb-jt/jf

    Description

    2-pipe 3-way valve mCwCn

    4-pipe 3-way valve mCwHn

    * to install ekrUmCa => ekaC10C needs to be installed on the unit. * ekaC10C allows direct connection to moDbUS bmS system * to install eklonPg & ekbnPg => ekaCPg needs to be installed on the unit.

    15. 2-pipe unit: 1 x valve kit + 1 x installation box for PCb krP1H98 + 1 x valve control PCb ekrP1C114-pipe unit: 2 x valve kit + 1 x installation box for PCb krP1H98 + 1 x valve control PCb ekrP1C 11 (fwC)

    16. 2-pipe unit: 1 x valve kit + 1 x installation box for PCb krP1ba101 + 1 x valve control PCb ekrP1C114-pipe unit: 2 x valve kit + 1 x installation box for PCb krP1ba101 + 1 x valve control PCb ekrP1C11 (fwf)»

    17. this option is needed to create t1 t2 wire.18. it is possible to change the operation mode, but this will not have an impact on the water temperature. (no feed back to water source) it is not possible to select

    the “auto airfl ow” setting.Dry operation can be selected with this remote control, but this function is not available on the fwC model.

    19. all options are supplied as kit.20. both parts of the fresh air intake are needed for each unit.

    tyPe fwt fwC-bt/bf fwf-bt/bfDescription

    Standard wired remote control merCa - -Simplifi ed wired remote control SrC-Cob - -Simplifi ed wired remote control SrC-HPb - -wireless control for cooling only wrC-Cob - -wireless control for heat pump wrC-HPb - -Decoration Panel (ral 9010 - grey sealings) 4-way blow - - byfQ60bDecoration Panel - Standard (ral 9010 - grey sealings) round fl ow - byCQ140Cw1Decoration Panel - white (ral 9010 - white sealings) round fl ow - byCQ140Cw1wSealing member of air discharge outlet - kDbHQ55C140 kDbH44ba60Panel spacer - - kDbQ44b60long-life fi lter - kafP551k160 kafQ441ba60fresh air intake kit - Direct installation type - - kDDQ44Xa60

    fresh air intake kit (20% fresh air) - Direct installation type - kDDQ55C140-1(*20) / kDDQ55C140-2 (*20) -

    remote controller - wireless - H/P - brC7f532f (*18) brC7e530 (*18)remote controller - wireless - C/o - brC7f533f (*18) brC7e531 (*18)remote controller - wired - brC315D7 (*4)Central remote controller - DCS302Ca51 (*5)electrical box with earth terminal (3 blocks) - kjb311aUnifi ed on/off controller - DCS301ba51 (*9)electrical box with earth terminal (2 blocks) - kjb212aSchedule timer - DSt301ba51 (*6)(*9) DSt301ba51 (*6)(*9)wiring adapter for electrical appendices (1) - krP2a52 (*7) (*12) krP2a52 (*9) (*12)wiring adapter for electrical appendices (2) - krP4aa53 (*7) (*12) krP4aa53 (*9) (*12)installation box for adapter PCb - krP1H98 (*13) krP1ba101 (*17)remote sensor - krCS01-4 krCS01-1intelligent touch controller - DCS601C51C(*6) (*11) DCS601C51C (*6) (*11)electrical installation box - kjb411aoptional PCb for moD-bus connection - ekfCmbCb7 (*8) (*12) ekfCmbCb7 (*8) (*12)

    2-way valve - on/off - ekmV2C09b7 (*8) (*10) (*15)ekmV2C09b7 (*8)

    (*10) (*16)

    3-way valve - on/off - ekmV3C09b7 (*8) (*10) (*15)ekmV3C09b7 (*8)

    (*10) (*16)Valve control PCb - ekrP1C11remote “on/off ” and “forced off ” kit - ekroroa (*17)

  • 9

  • 10

    Daikin Europe N.V.

    about DaikinDaikin has a worldwide reputation based on 85 years’ experience in the successful manufacture of high quality air conditioning equipment for industrial, commercial and residential use.

    DAIkIN qUAlITy

    Daikin’s much envied quality quite simply stems from the close attention paid to design, production and testing as well as aftersales support. To this end, every component is carefully selected and rigorously tested to verify its contribution to product quality and reliability.

  • 11

    SmART CoNTRol bRINgS ComfoRT AND REDUCES ENERgy CoNSUmpTIoN

    Inverter technology used in the air cooled mini Chiller (EWAq-AC & EWyq-AC)

    allows more precise control of the leaving water condition in function of the

    load. This leads to energy savings and high comfort levels, ensuring it is never

    too cool or too hot. This is a major advantage over standard fixed speed models,

    which use on/off cycling of the compressor, creating greater fluctuations in

    control conditions.

    environmental awareness DAIkIN AND ThE ENVIRoNmENT

    Air conditioning systems provide a significant level of indoor comfort, making

    possible optimum working and living conditions in the most extreme climates.

    In recent years, motivated by a global awareness of the need to reduce the burdens

    on the environment, some manufacturers including Daikin have invested a geat

    deal in limiting the negative effects associated with the production and the

    operation of air conditioners.

    hence, models with energy saving features and improved eco-production

    techniques have seen the light of day, making a significant contribution to limiting

    the impact on the environment.

  • 12

    INVERTER TEChNology

    Inverter technology offers improved levels of comfort:

    › Energy efficient: continuous matching of load requirement

    › Start-up time is reduced by 1/3

    › less frequent start/stop cycles

    › Reduced sound levels

    › high EER /Cop values

    Shorter start-up

    Temperature remains stableWater temperature

    Time

    Set temp. Chiller

    with Inverter

    Chiller

    without Inverter

  • 13

    Inverter technology for higher efficiency both inverter drive (ID) and variable frequency drive (VfD) are terms used to describe a piece of electrical hardware that is used to start, stop, and control the speed of an electric motor. When fitted to a single screw compressor or scroll compressor, an inverter allows it to continuously adapt the cooling capacity to the requirement of the building load by controlling the speed of the compressor motor.

    Traditional systems using electric motors running at full speed even when unloaded waste electricity and with most building energy being consumed by hVAC operations, possible savings are important. With soaring energy prices and global warming concerns, our variable frequency drives for hVAC compressors, pumps, fans and motors are a major efficiency improvement as well as an energy saver and these combine to reduce costs.

    The full range of Daikin chillers now come with inverters already fitted or with an inverter alternative.

    Principal benefits

    • Energy efficient: displacement power factor always > 0.95 Usually the power factor of a motor progressively worsens with the decrease of the power output. however thanks to the inverter, there is no need for additional power factor correction capacitors as the power factor is always > 0.95 and there are no power surges and so costs are constrained.

    • quick start-up: start up time reduced by 1/3 The ability to vary the output power in direct relation to the cooling requirements of the system by allowing compressor boosts, gives the inverter chiller a reduced start-up-to-operating-capacity making it possible to achieving building comfort conditions in 1/3 less time than with conventional systems.

    • less frequent start/stop cycles and low starting current The inverter technology ensures fewer start/stop cycles as well as ensuring that the start-up current is always lower than current absorbed in the maximum operating conditions (flA). This generates obvious cost savings.

    • Seasonal quietness: reduced sound levels low sound levels in partial load conditions are achieved by the variation of compressor frequency, thus ensuring the minimum sound levels at all times.

  • 14

    ThE SCRoll CompRESSoR foR CoNTRollED CApACITy:

    whatever the requirements of the customer, large systems requiring constant capacity or smaller systems for flexibility, Daikin always provides a reliable and efficient solution.

    reliable and efficient

    being compact, the Daikin scroll compressor is used with R-407C and R-410A toprovide constant reliability and high efficiency right throughout its service life. Designed for small and medium capacities, the scroll compressors are used with air cooled and water cooled chillers within the range of capacities between 9.1 and 281kW.

    Characteristics :

    › Compact, simple yet robust design › Absence of valves and oscillating connecting

    mechanisms providing maximum reliability › Constant compression guaranteeing low energy consumption › Increased compression efficiency thanks to

    the absence of volumetric re-expansion › low sound level › low starting current

    ThE SWINg CompRESSoR:

    The mini Chiller series EWAq005-007ACV3 & EWyq005-007ACV3 are equipped with a swing compressor. This innovative design by Daikin with fewer moving parts allows smoother more reliable operation with low vibration and low noise levels. The high efficiency motor reduces energy consumption resulting in energy cost savings.

    swing

    the piston which the bladeand the roller unified

    ref. gas

    Swing bush scroll

  • 15

    1

    2

    38 4

    6

    910

    7

    12

    11

    5

    As standard, condensers for air cooled chillers are given anti-corrosion treatment. This treatment significantly increases resistance to acid rain and saline corrosion. Depending on the capacities and models, treatments are of the following type:

    example of acrylic treatment

    1. Casing2. Slide valve3. Screw rotor4. bearing5. motor6. gate rotor

    7. 2nd stage oil separator8. Demister (oil separator)9. Refrigerant suction10. Refrigerant discharge11. Compressor terminal + CTp12. Stepper motor

    ThE SINglE SCREW STEplESS CompRESSoR foR hIgh CApACIT y:

    Characteristics :

    › optimal performance through stepless capacity control in function of the chilled water temperature. The unit capacity is infinitely variable from 30 - 100% on single circuit units and 15 - 100% on dual circuit units.

    › Compact, simple yet robust construction. › Using a main single screw and two gate rotors, axial and

    radial forces are balanced thanks to the symmetrical compression guaranteeing low bearing loads.

    › Renowned for its low noise levels the double walled casing design and integrated oil separator, add to the attenuation effect.

    › gate rotors made of polymer material result in closer tolerances with main screw and reduced friction greatly improving compressor efficiency and lifetime.

    › No oil pump necessary – lubrication based on differential pressure principle.

    › Easy access to both compressor and safety devices › Star delta starter with low starting current as standard

    The heart of the larger Daikin chillers is a semi hermetic single screw compressor, designed, tested and manufactured in Daikin’s own laboratories, in order to meet the highest capacity, performance and maintenance specifications. This compressor has been especially developed for operation with R-410A, R-134a or R-407C refrigerant, guaranteeing unequalled reliabi-lity and many years of efficient operation. The bearing life is 100,000hrs with inspection and maintenance intervals every 40,000hrs.

    STANDARD ANTI -CoRRoSIoN TREATmENT

    screw

    Acrylic treatment (Daikin ref PE)

    The aluminium fins are coated with an acrylic resin and a hydrophilic film. Epoxy Treatment

    The aluminium fins are black epoxy coated.

  • 16

    air Cooled

    ewaQ-aCV3 & ewaQ-aCw1 16

    ewyQ-aCV3 & ewyQ-aCw1 18

    eUwaC-fbzw1 20

    eUwa*-kbzw1 22

    eUwy*-kbzw1 24

    ewaQ-Dayn 26

    ewyQ-Dayn 28

    in the chilled water market, chillers of the air cooled

    type are most frequently used. out of its wide range

    of chillers in cooling only or heat pump version,

    with or without integrated hydronic components,

    Daikin always offers you a chiller fitting your

    application needs.

    TAblE of CoNTENTS

  • Daikin has taken great care to match major chiller components and refrigerant combinations to a point where high efficiency ranges of technically advanced and closely optimised air and water cooled units are now widely available for use with R-410A, R-407C and R-134a refrigerants.

    A IR CoolED ChIllER

    1. Temperature sensor2. filter3. Shut-off valve4. pump

    5. pressure port6. flow switch7. Air purge8. pressure gauge

    9. balancing valve10. Drain valve11. Charging valve12. Safety valve

    57 3 2 4 5

    101198561

    1

    t

    t

    t

    EVA

    poRA

    ToR

    To fan coil units

    buffer Tank

    Expa

    nsio

    nve

    ssel

    Chillers

    swing scroll screw

  • 18

    ewAQ-Ac air cooled mini chiller inverter

    Digital Controller

    StrengtHS › optimised for use with R-410A › Inverter controlled swing compressor

    (size 005-007) - precise temperature control

    › Inverter controlled scroll compressor (size 009-011)

    › low operating sound level › Easy ‘plug and play installation’ › Wide operating range › Integrated hydronics

    oPtionS (faCtory moUnteD) › Evaporator heater tape

    oPtion kit › Digital Input/output pCp (size 009-013 only)

    Control › leaving water control

    aVailable inPUtS › Voltage free contact:

    - oN/off Schedule timer:- oN/off - Silent operation

    s c r o l ls w i n g

  • 19

    ewaQ005-007aCV3 + ewaQ009-011aCV3 / ewaQ009-013aCw1

    Cooling onlycapacity class

    ewAQ-AcV3 ewAQ-Acw1005 006 007 009 010 011 009 011 013

    Cooling capacity nom. kw 5.2 6.0 7.1 8.5 9.5 11.0 9.0 11.0 13.2Power input Cooling nom. kw 1.89 2.35 2.95 2.74 3.19 3.82 2.96 3.82 5.10 eer 2.75 2.55 2.41 3.11 2.98 2.88 3.04 2.88 2.59 eSeer 3.75 3.83 3.87 4.57 4.52 4.46 4.68 4.63 4.52Dimensions Unit HeightxwidthxDepth mm 805x1,190x360 1,435x1,418x382weight Unit kg 100 180water heat exchanger

    type brazed platewater volume l - 1.01nominal water flow

    Cooling l/min 14.9 17.2 20.4 24.4 27.2 31.5 25.8 31.5 37.8

    air heat exchanger type tube type Hi-XSSPump nominal eSP unit Cooling kPa 49.4 45.1 38.3 58.0 54.6 49.1 56.4 49.1 40.9Hydraulic components expansion vessel Volume l 6 10 10fan air flow rate Cooling nom. m³/min - 96 100 97 -fan motor Speed Cooling nom. rpm - 780

    Steps - 8Sound power level Cooling nom. dba 62 63 64 66Sound pressure level

    Cooling nom. dba 48 50 51 52night quiet mode Cooling dba - 45 46

    Compressor type Hermetically sealed swing compressor Hermetically sealed scroll compressoroperation range water side Cooling min.~max. °CDb 5~20 5~22

    air side Cooling min.~max. °CDb 10~43 10~46refrigerant type r-410a

    Charge kg 1.7 2.95Control electronic expansion valveCircuits Quantity 1

    water circuit Piping connections diameter inch - g 5/4" (female)Piping inch - 5/4"

    Piping connections

    water heat exchanger inlet / outlet 1" mbSP -water heat exchanger drain Hose nipple 1/2" fbSP -

    Power supply Phase / frequency / Voltage Hz / V 1~ / 50 / 230 3n~ / 50 / 400

  • 20

    ewYQ-Ac air cooled mini chiller inverter

    Digital Controller

    StrengtHS › optimised for use with R-410A › Inverter controlled swing compressor › (size 005-007)

    - precise temperature control › Inverter controlled scroll compressor

    (size 009-011) › low operating sound level › Easy ‘plug and play’ installation › Integrated hydronics › Wide operating range

    oPtionS (faCtory moUnteD) › Evaporator heater tape

    oPtion kit › Digital Input/output pCp (size 009-013 only)

    Control › leaving water control › Setpoint in heating & cooling

    aVailable inPUtS › Voltage free contact:

    - oN/off- Cooling/heating changeover

    › Schedule timer:- oN/off- Dual setpoint- Silent operation

    s c r o l ls w i n g

  • 21

    ewyQ005-007aCV3 + ewyQ009-011aCV3/ewyQ009-013aCw1

    Heating & CoolingCapacity class

    ewyQ-aCV3 ewyQ-aCw1005 006 007 009 010 011 009 011 013

    Cooling capacity nom. kw 5.2 6.0 7.1 8.5 9.5 11.0 9.0 11.0 13.2Heating capacity nom. kw 5.65 6.35 7.75 10.0 11.5 13.0 11.0 12.5 14.0Power input Cooling nom. kw 1.89 2.35 2.95 2.74 3.19 3.82 2.96 3.82 5.10

    Heating nom. kw 1.97 2.24 2.83 2.91 3.38 3.86 3.23 3.70 4.19 eer 2.75 2.55 2.41 4.37 2.98 2.88 3.04 2.88 2.59 CoP 2.87 2.83 2.74 3.44 3.40 3.37 3.41 3.38 3.34 eSeer - 4.57 4.52 4.46 4.68 4.63 4.52Dimensions Unit HeightxwidthxDepth mm 805x1,190x360 1,435x1,418x382weight Unit kg 100 180

    operation weight kg 104 -water heat exchanger

    type brazed platewater volume l - 1.01nominal water flow

    Cooling l/min 14.9 17.2 20.4 24.4 27.2 31.5 25.8 31.5 37.8 Heating l/min 17.5 19.5 23.5 28.7 33.0 37.3 31.5 35.8 40.1

    air heat exchanger type tube type Hi-XSS Pump nominal eSP unit Cooling kPa 49.4 45.1 38.3 58.0 54.6 49.1 56.4 49.1 40.9Hydraulic components expansion vessel Volume l 6 10fan air flow rate Cooling nom. m³/min - 96 100 97 -

    Heating nom. m³/min - 90 -fan motor Speed Cooling nom. rpm - 780

    Heating nom. rpm - 760Steps - 8

    Sound power level Cooling nom. dba 62 63 64 66 Heating nom. dba - 64

    Sound pressure level

    Cooling nom. dba 48 50 51 52 Heating nom. dba 48 49 51night quiet mode

    Cooling dba - 45 46Heating dba - 42 43

    Compressor type Hermetically sealed swing compressor Hermetically sealed scroll compressoroperation range water side Cooling min.~max. °CDb 5~20 5~22

    Heating min.~max. °CDb 25~50 25~50 air side Cooling min.~max. °CDb 10~43 10~46

    Heating min.~max. °CDb -15~25 -15~35refrigerant type r-410a

    Charge kg 1.7 2.95Control electronic expansion valveCircuits Quantity 1

    water circuit Piping connections diameter inch - g 5/4" (female)Piping inch - 5/4"

    Piping connections

    water heat exchanger inlet / outlet 1" mbSP -water heat exchanger drain Hose nipple 1/2" fbSP -

    Power supply Phase / frequency / Voltage Hz / V 1~ / 50 / 230 3n~ / 50 / 400

  • euwAc-fBZw1 air cooled chiller with centrifugal fan

    s c r o l l

    StrengtHS › optimised for use with R-407C › Daikin scroll compressor › Electronic DDC controller › Standard phase sequence controller › maximum external static pressure (ESp): 150pa › pressure gauges › Standard operation range down to -10°C › Regulating switch › Water inlet or outlet temperature control › Input contacts/available outputs › Input: on/off (per circuit), pump/flow switch › outputs: compressor operation, summary

    alarm, pump relay contact › Compatible with hydraulic module › µC² SE controller

    oPtionS (faCtory moUnteD) › Chilled water temperature

    down to - 5°C (opZh) or -10°C (opZl)* opZh: option lWE high glycol

    opZl: option lWE low glycol

    aCCeSSorieS (kit) › Address card for connection to bmS or

    remote user interface (EkAC10C) › Remoted installed user interface (EkRUmCA)

    * To install EkRUmCA -> EkAC10C needs to be installed on the unit

    Control › Water inlet temperature control

    aVailable inPUtS / oUtPUtSinput › oN / off (per circuit) › pump / flow switch

    output › Compressor operation › Summary alarm › pump relay contact

    22

    µC2 Se

  • eUwaC8fbzw1

    23

    Cooling onlyCapacity class 5 8 10Cooling capacity nom. kw 11.6 18.4 23.8Capacity steps % 100-0Power input Cooling nom. kw 5.2 7.66 9.67eer 2.23 2.40 2.46Dimensions Unit HeightxwidthxDepth mm 1,345x856x630 1,290x1,180x630 1,395x1,330x630weight Unit kg 164 224 261

    operation weight kg 166 228 266water heat exchanger - evaporator

    type brazed plate, one per circuitminimum water volume in the system l 101 153 212water flow rate nom. l/min 33 53 68nominal water pressure drop

    Cooling Heat exchanger

    kPa 26 42 48

    model type aC70-24 aC70-34 aC70-40Quantity 1

    air heat exchanger type Cross fin coil/Hi-X tubes and Pe coated waffle louvre finsfan air flow rate nom. m³/min 70.2 109.8 126Sound power level Cooling nom. dba 63 66 69Compressor type Hermetically sealed scroll compressoroperation range water side Cooling min.~max. °CDb -10 (oPzl) ~ 21

    air side Cooling min.~max. °CDb -10 ~ 43refrigerant type r-407C

    Control thermostatic expansion valveCircuits Quantity 1

    refrigerant circuit Charge kg 2.1 3.9 4.7Piping connections

    evaporator water inlet/outlet fbSP 1"evaporator water drain field installation

    Power supply Phase / frequency / Voltage Hz / V 3n~ / 50 / 400

  • euwA*-kBZw1 air cooled chiller

    s c r o l l

    StrengtHS › optimised for use with R-407C › Daikin scroll compressor › Reduced installation time thanks to

    integrated pump and and/or buffer tank › possibility for a 200l buffer tank › low operating sound level › Easy maintenance › main switch › Water flow switch › 3 different design options available:

    - EUWAN chiller without integrated hydraulic module ; - EUWAp chiller with integrated hydraulic module

    (pump, expansion vessel, hydraulic components) ; - EUWAb chiller with integrated hydraulic

    module (buffer tank, pump, expansion vessel, hydraulic components)

    › µC² SE controller

    oPtionS (faCtory moUnteD) › Chilled water temperature down

    to - 5°C (opZh) or -10°C (opZl) › high ESp fans (50pa) (ophf) › pump size up (ophp)

    * opZh: option lWE high glycol

    opZl: option lWE low glycol

    aCCeSSorieS (kit) › Refrigerant pressure gauges

    (EkgAU5/8/10/12/16/20/24kA) › 200l buffer tank (EkbT, see EkbT page in this catalogue) › Soft starter kit (EkSS) › Address card for connection to bmS or

    remote user interface (EkAC10C) › Remote installed user interface (EkRUmCA)

    * To install EkRUmCA -> EkAC10C needs to be installed on the unit

    Control › Water inlet temperature control

    aVailable inPUtS / oUtPUtSinput › Remote oN / off › pump contact

    output › Compressor operation › Summary alarm › pump relay contact

    air purge

    buffer tank

    water Pressure gauge

    expansion vessel

    Drain

    Pressure port

    Safety valve

    flow switch

    Pump

    water flow adjusting valve

    HyDraUliC CirCUit ComPonentS

    24

    µC2 Se

  • eUwan: › Scroll compressor › main isolator switch › Water flow switch › filter › Condenser protection grille › All year operation

    eUwaP = eUwan + › pump › Expansion vessel › Adjusting valve › Drain › Water pressure gauge › pressure relief valve

    eUwab = eUwaP + › buffer tank

    25

    eUwa*16kbzw1

    Cooling onlyCapacity class n5 P5 b5 n8 P8 b8 n10 P10 b10 n12 P12 b12 n16 P16 b16 n20 P20 b20 n24 P24 b24Cooling capacity nom. kw 11.3 19.7 22.5 26.5 34.6 46.6 55.3 Capacity steps % 0-100 0-50-100Power input Cooling nom. kw 4.48 7.27 8.64 11.50 14.70 17.90 23.80eer 2.53 2.46 2.60 2.30 2.35 2.60 2.32Dimensions Unit HeightxwidthxDepth mm 1,230x1,290x734 1,450x1,290x734 1,321x2,580x734 1,541x2,580x734weight Unit kg 150 168 180 215 229 241 245 259 271 248 262 274 430 448 460 490 508 520 496 514 526

    operation weight kg 152 171 239 218 232 300 248 262 330 251 265 335 436 457 525 496 518 545 503 524 592water heat exchanger

    type brazed platewater volume l 1.14 1.615 1.9 2.375 2.964 3.9 4.524nominal water flow Cooling l/min 32 51 64 76 99 134 158nominal water pressure drop

    Cooling Heat exchanger

    kPa 24 38 43 37 22

    air heat exchanger type Cross fin coil/Hi-X tubes and Pe coated waffle louvre finsHydraulic components expansion vessel Volume l - 12 - 12 - 12 - 12 - 12 - 12 - 12fan group air flow rate Cooling nom. m³/min 160 (per 2 fans) 170 (per 2 fans)fan group 2 air flow rate Cooling nom. m³/min - 170 (per 2 fans)Sound power level Cooling nom. dba 67 76 78 79 81Compressor type Hermetically sealed scroll compressoroperation range water side Cooling min.~max. °CDb -10 (oPzl) ~ 25

    air side Cooling min.~max. °CDb -15 ~ 43refrigerant type r-407C

    Control thermostatic expansion valveCircuits Quantity 1 2

    refrigerant circuit Charge kg 3.9 4.6 5.9 6.0 4.6 5.9 6.0refrigerant circuit 2 Charge kg - 4.6 5.9 6.0water circuit Piping connections diameter inch g 1"1/4 (male) 2" male

    Piping inch 1-1/4" -Power supply Phase / frequency / Voltage Hz / V 3n~ / 50 / 400

  • 26

    euwY*-kBZw1 air cooled chiller

    s c r o l l

    StrengtHS › optimised for use with R-407C › Daikin scroll compressor › Reduced installation time thanks to

    integrated pump and/or buffer tank › possibility for a 200l buffer tank › low operating sound level › Easy maintenance › main switch › Water flow switch › 3 different design options available:

    - EUWyN chiller without integrated hydraulic module;- EUWyp chiller with integrated hydraulic module

    (pump, expansion vessel, hydraulic components); - EUWyb chiller with integrated hydraulic

    module (buffer tank, pump, expansion vessel, hydraulic components)

    › µC² SE controller

    oPtionS (faCtory moUnteD) › Chilled water temperature down

    to - 5°C (opZh) or -10°C (opZl) › high ESp fans (50pa) (ophf) › pump size up (ophp)

    * opZh: option lWE high glycol

    opZl: option lWE low glycol

    aCCeSSorieS (kit) › Refrigerant pressure gauges

    (EkgAU5/8/10/12/16/20/24kA) › 200l buffer tank (EkbT, see EkbT page in this catalogue) › Soft starter kit (EkSS) › Address card for connection to bmS or

    remote user interface (EkAC10C) › Remote installed user interface (EkRUmCA)

    * To install EkRUmCA -> EkAC10C needs to be installed on the unit

    Control › Water inlet temperature control

    aVailable inPUtS / oUtPUtSinput › Remote oN / off › pump contact › Remote cool / heat selection

    output › Compressor operation › Summary alarm › pump relay contact

    µC2 Se

  • eUwy*16kbzw1

    eUwyn: Standard equipment › Scroll compressor › main isolator switch › Water flow switch › filter › Condenser protection grille. › All year operation

    eUwyP = eUwyn + › pump › Expansion vessel › Adjusting valve › Drain › Water pressure gauge › pressure relief valve

    eUwyb = eUwyP + › buffer tank

    27

    Heating & CoolingCapacity class n5 P5 b5 n8 P8 b8 n10 P10 b10 n12 P12 b12 n16 P16 b16 n20 P20 b20 n24 P24 b24Cooling capacity nom. kw 9.1 17.1 21.0 25.0 34.2 40 50.0Heating capacity nom. kw 11.9 18.5 24.0 27.0 37.0 46 54.0Capacity steps % 0-100 0-50-100Power input Cooling nom. kw 3.77 7.38 8.49 11.3 14.8 16.2 22.6

    Heating nom. kw 4.56 7.01 8.98 10.7 14.10 17.3 21.4eer 2.41 2.32 2.47 2.21 2.3 2.5 2.2CoP 2.61 2.64 2.67 2.52 2.62 2.66 2.52Dimensions Unit HeightxwidthxDepth mm 1,230x1,290x734 1,450x1,290x734 1,321x2,580x734 1,541x2,580x734weight Unit kg 163 181 193 227 241 253 258 272 284 258 272 284 455 473 485 516 534 546 516 534 546

    operation weight kg 165 184 252 230 244 312 261 275 343 261 275 343 461 482 550 522 544 612 522 544 612water heat exchanger

    type brazed platewater volume l 1.140 1.615 1.900 2.375 2.964 3.900 4.524nominal water flow

    Cooling l/min 26 49 60 72 98 115 143Heating l/min 34 53 69 77 106 132 155

    nominal water pressure drop

    Cooling filter kPa 10 25 24 33 12 19Heating filter kPa 17 29 31 38 14 16 22

    air heat exchanger type Cross fin coil/Hi-X tubes and Pe coated waffle louvre finsHydraulic components expansion vessel Volume l - 12 - 12 - 12 - 12 - 12 - 12 - 12fan group air flow rate Cooling nom. m³/min 160 (per 2 fans) 170 (per 2 fans)fan group 2 air flow rate Cooling nom. m³/min - 170 (per 2 fans)Sound power level Cooling nom. dba 67 76 78 79 81Compressor type Hermetically sealed scroll compressoroperation range water side Cooling min.~max. °CDb -10(oPzl) ~ 20

    Heating min.~max. °CDb 35 ~ 50air side Cooling min.~max. °CDb -15 ~ 43

    Heating min.~max. °CDb -10 ~ 21refrigerant type r-407C

    Control thermostatic expansion valveCircuits Quantity 1 2

    refrigerant circuit Charge kg 4.6 4.7 5.4 5.1 5.4 5.6refrigerant circuit 2 Charge kg - 5.1 5.4 5.6water circuit Piping connections diameter inch g 1"1/4 (male) 2" male

    Piping inch 1-1/4" 2"Power supply Phase / frequency / Voltage Hz / V 3n~ / 50 / 400

  • ewAQ-dAYn air cooled chiller, multiple scroll

    PCaSo

    s c r o l l

    StrengtHS › optimised for use with R-410A refrigerant › multiple compressors per circuit › Reliable and efficient scroll with high EER values › Anti-corrosion treated aluminium coils › low operating sound level › Easy ‘plug and play’ installation › fans protected against abnormal operation

    (4 - 8 fans depending on unit size) › Safety valves in each circuit › Electronic circuit breakers › Electronic expansion valve › True dual plate brazed plate heat exchanger › All hydronics can be accessed easily from

    3 sides (no surrounding cabinet) › Separate switchbox for easy access › Compressors and controls at unit side › Increased reliability via 2 independent

    refrigerant circuits (EWAq130-260DAyN) › Double circuit heat exchanger (from >100 kW) › Non hermetic filter/dryer › Daikin pcaso controller with user friendly

    and powerful lCD interface

    oPtionS (faCtory moUnteD) › Single pump contactor (opSC) › Twin pump contactor (opTC) › Single pump (opSp) › Twin pump (opTp) (1 pump casing, dual motor) › high ESp pump (ophp) (single pump only) › buffer tank (opbT) › Inverter fans (opIf) (Not available with option oplN) › glycol 0°C / -10°C (opZl) › Evaporator heater tape (op10) › option valves

    (discharge, liquid line and suction stop valve: op12) › A-meter / V-meter (op57) › low Noise (oplN) (=opIf + compressor housing) › Condenser protection grills (opCg)

    aCCeSSorieS (kit) › gateway for loN (EkloNpg) › gateway for bACNET (EkbNpg) › Address card (EkACpg) › Remote user interface (EkRUpg)

    28

  • ewaQ130,150Dayn

    29

    Cooling onlyCapacity class 080 100 130 150 180 210 240 260Cooling capacity nom. kw 80 105 131 152 182 209 236 254Capacity steps %

    0-50-100 0-25-50-75-10021/29-

    43/50/57-71/79-100

    0-25-50-75-10022/28-

    40/50/56-72/78-100

    0-25-50-75-100

    Power input Cooling nom. kw 26.4 36.2 46.6 56.3 64.5 74.6 82.8 94.0eer 3.03 2.90 2.81 2.70 2.82 2.80 2.85 2.70eSeer 4.12 4.00 4.34 4.22 4.36 4.32 4.20 4.00Dimensions Unit HeightxwidthxDepth mm 2,311x2,000x2,566 2,311x2,000x2,631 2,311x2,000x3,081 2,311x2,000x4,850weight Unit kg 1,350 1,400 1,500 1,550 1,800 1,850 3,150 3,250

    operation weight kg 1,365 1,415 1,517 1,569 1,825 1,877 3,189 3,292water heat exchanger

    type brazed platenominal water flow Cooling l/min 229 301 377 436 522 599 677 728nominal water pressure drop

    Cooling total kPa 59 58 52 49 52 53 51 47

    air heat exchanger type Cross fin coil/Hi-Xss tubes and poly ethylene coated waffle finsfan air flow rate nom. m³/min 780 800 860 1,290 1,600

    Speed rpm 880 900 970 900Sound power level Cooling nom. dba 86 88 89 90 91Compressor type Scroll compressoroperation range water side Cooling min.~max. °CDb -10 (oPzl) ~ 25

    air side Cooling min.~max. °CDb -15 ~ 43refrigerant type r-410a

    Charge kg 33 19 25 29 28 39Control electronic expansion valveCircuits Quantity 1 2

    Piping connections

    water heat exchanger inlet / outlet 3" oD 3"water heat exchanger drain 1/2"g

    Power supply Phase / frequency / Voltage Hz / V 3~ / 50 / 400

  • ewYQ-dAYn air cooled chiller, multiple scroll

    PCaSo

    s c r o l l

    StrengtHS › optimised for use with R-410A refrigerant › multiple compressors per circuit › Reliable and efficient scroll with high EER values › Anti-corrosion treated aluminium coils › low operating sound level › Easy ‘plug and play’ installation › fans protected against abnormal operation

    (4 - 8 fans depending on unit size) › Safety valves in each circuit › Electronic circuit breakers › Electronic expansion valve › True dual plate brazed plate heat exchanger › All hydronics can be accessed easily from

    3 sides (no surrounding cabinet) › Separate switchbox for easy access › Compressors and controls at unit side › Increased reliability via 2 independent

    refrigerant circuits (EWyq130-250DAyN) › Double circuit heat exchanger (from >100 kW) › Non hermetic filter/dryer › Daikin pcaso controller with user friendly

    and powerful lCD interface

    oPtionS (faCtory moUnteD) › Single pump contactor (opSC) › Twin pump contactor (opTC) › Single pump (opSp) › Twin pump (opTp) (1 pump casing, dual motor) › high ESp pump (ophp) (single pump only) › buffer tank (opbT) › Inverter fans (opIf) (Not available with option oplN) › glycol 0°C / -10°C (opZl) › Dual pressure relief valve (op03) › Evaporator heater tape (op10) › option valves

    (discharge, liquid line and suction stop valve: op12) › A-meter / V-meter (op57) › low Noise (oplN) (=opIf + compressor housing) › Condenser protection grills (opCg)

    aCCeSSorieS (kit) › gateway for loN (EkloNpg) › gateway for bACNET (EkbNpg) › Address card (EkACpg) › Remote user interface (EkRUpg)

    30

  • ewyQ130,150Dayn

    31

    Heating & CoolingCapacity class 080 100 130 150 180 210 230 250Cooling capacity nom. kw 77 100 136 145 183 211 231 252Heating capacity nom. kw 87.7 114 149 165 199 225.00 258 281Capacity steps %

    0-50-100 0-25-50-75-10021/29-

    43/50/57-71/79-100

    0-25-50-75-10022/28-

    44/50/56-72/78-100

    0-25-50-75-100

    Power input Cooling nom. kw 26.5 36.2 47.6 55.7 63.8 75.3 82.2 93.5Heating nom. kw 30.0 38.1 49.6 58.8 68.0 77.0 84.2 96.6

    eer 2.91 2.76 2.86 2.60 2.87 2.80 2.81 2.70CoP 2.92 2.99 3.00 2.81 2.93 2.92 3.06 2.91eSeer 4.00 3.81 4.31 4.07 4.33 4.23 4.20 4.00Dimensions Unit HeightxwidthxDepth mm 2,311x2,000x2,566 2,311x2,000x2,631 2,311x2,000x3,081 2,311x2,000x4,850weight Unit kg 1,400 1,450 1,550 1,600 1,850 1,900 3,200 3,300

    operation weight kg 1,415 1,465 1,567 1,619 1,875 1,927 3,239 3,342water heat exchanger

    type brazed plate, one per unitnominal water flow

    Cooling l/min 221 287 390 416 525 605 662 722Heating l/min 251 327 427 473 570 645 740 806

    nominal water pressure drop

    Cooling total kPa 36 43 38 41 44 39 38Heating total kPa 47 46 51 49 48 50 48 46

    air heat exchanger type Cross fin coil/Hi-Xss tubes and poly ethylene coated waffle finsfan air flow rate nom. m³/min 780 800 860 1,290 1,600

    Speed rpm 880 900 970 900Sound power level Cooling nom. dba 86 88 89 90 91Compressor type Scroll compressoroperation range water side Cooling min.~max. °CDb -10 (oPzl) ~ 25

    water side Heating min.~max. °CDb 25 ~ 50air side Cooling min.~max. °CDb -15 ~ 43air side Heating min.~max. °CDb -10 ~ 21

    refrigerant type r-410aControl electronic expansion valveCircuits Quantity 1 2

    refrigerant circuit Charge kg 33 37 22 32 39refrigerant circuit 2 Charge kg - 22 32 39Piping connections

    water heat exchanger inlet / outlet 3" oD 3"water heat exchanger drain 1/2"g

    Power supply Phase / frequency / Voltage Hz / V 3~ / 50 / 400

  • 32

    water CooledDaikin offers you compact

    water cooled chiller units which require only

    very limited space in a machine room.

    Used for commercial or industrial applications,

    these chillers generate cold and hot water,

    which can be used for chilling, heating,

    or even both at the same time.

    TAblE of CoNTENTS

    ewwP-kbw1n 32

    ewwD-bjynn 34

  • 1. balancing valve2. pressure gauge3. Temperature sensor4. Drain valve5. Shut-off valve6. fill valve7. filter8. Drain9. Safety valve10. pressure port11. pump12. flow switch13. pressure regulating valve14. bypass valve

    p I p I N g D I A g R A m f o R C o m f o R T C o o l I N g A p p l I C AT I o N

    Chillers

    Evap

    orat

    or

    expan-sion

    vessel

    buffer tank

    Cond

    ense

    r

    expan-sion

    vessel

    buffer- tank

    To fan coil units

    To fan coil units

  • 34

    ewwP-kBw1n water cooled chiller

    s c r o l l

    StrengtHS › Standard integrated: main switch, water

    filter, flow switch, air purge, pressure ports › Daikin scroll compressor › optimised for use with R-407C › Electronic DDC controller › low operating sound level › low energy consumption › Extension possible up to 72hp › Compact dimensions and low refrigerant volume › Easy installation and maintenance › Stainless steel plate heat exchanger › Remote cooling or heating selection › Water/water heat pump, with water reversibility › Compatible with hydraulic module › µC² SE CoNTRollER › pCo3 controller for assembly of 2 or 3 modules

    for Single moDUle UnitS › Standard main isolator switch › basic hydraulic components

    for kA-series included with the unit as a kit: flow switch, air purge, filter + shut-off valves for both condenser and evaporator

    oPtionS (faCtory moUnteD) › Chilled water temperature down

    to - 5°C (opZh) or -10°C (opZl)

    aCCeSSorieS (kit) › Compressor soundproof material (-3dbA) › hydraulic module

    (see page EhmC-page in this catalogue) › bmS gateway (moDbUS/J-

    bUS / bACNET protocol) › Remote user interface

    Control › microprocessor control › Water inlet

    temperature control › Cold water or hot water regulation

    aVailable inPUtS / oUtPUtSinput › Remote oN / off › pump contact › Cool/heat selection

    output › Compressor operation › Summary alarm › pump relay contact

    µC2 Se

  • 35

    ewwP014-035kbw1n ewwP090-130kbw1n ewwP145-195kbw1n

    Heating only & Cooling onlyCapacity class 014 022 028 035 045 055 065 090 100 110 120 130 145 155 165 175 185 195Cooling capacity nom. kw 13.0 21.5 28.0 32.5 43.0 56.0 65.0 86.0 99.0 112 121 130 142 155 168 177 186 195 Heating capacity nom. kw 16.6 27.3 35.4 41.2 54.8 71.4 82.7 110 126 143 154 165 181 198 214 226 237 248Capacity steps number 1 2 4 6Power input Cooling nom. kw 3.61 5.79 7.48 8.75 11.80 15.50 17.60 23.6 27.3 31.0 33.1 35.2 39.1 42.8 46.5 48.6 50.7 52.8eer 3.60 3.71 3.74 3.71 3.64 3.61 3.69 3.64 3.63 3.61 3.66 3.69 3.63 3.62 3.61 3.64 3.67 3.69Dimensions Unit HeightxwidthxDepth mm 600x600x600 600x600x1,200 1,200x600x1,200 1,800x600x1,200weight Unit kg 118 155 165 172 300 320 334 600 620 640 654 668 920 940 960 974 988 1.002

    operation weight kg -water heat exchanger - evaporator

    type brazed plateminimum water volume in the system l 62 103 134 155 205 268 311 205 268 311 205 268 311water flow rate min. l/min 19 31 40 47 62 80 93 123 142 161 173 186 204 222 241 254 267 280

    nom. l/min 37 62 80 93 123 161 186 247 284 321 347 373 407 444 482 507 533 559max. l/min 75 123 161 186 247 321 373 493 568 642 694 745 814 889 963 1,015 1,066 1,118

    water heat exchanger - condenser

    type brazed platewater flow rate min. l/min 24 39 51 59 79 102 118 157 181 205 221 237 260 283 307 323 339 355

    nom. l/min 48 78 102 118 157 205 237 314 362 410 442 474 519 567 614 647 679 711max. l/min 95 157 203 237 314 410 474 629 724 819 883 948 1,038 1,133 1,229 1,293 1,357 1,422

    Sound power level Cooling nom. dba 64 71 67 74 71 75 77 73 76 78 79Compressor type Hermetically sealed scroll compressoroperation range evaporator Cooling min.~max. °CDb -10 (oPzl) ~ 25

    Condenser Cooling min.~max. °CDb 20 ~ 55refrigerant type r-407C

    Control thermostatic expansion valveCircuits Quantity 1 2 4 6

    refrigerant circuit Charge kg 1.2 2 2.5 3.1 4.6 5.6 9.2 10.2 11.2 13.8 14.8 15.8 16.8Piping connections

    evaporator water inlet/outlet fbSP 25mm fbSP 40mm 2 x 2 x fbSP 38mm 3 x 2 x fbSP 38mmevaporator water drain field installationCondenser water inlet/outlet fbSP 25mm fbSP 40mm 2 x 2 x fbSP 38mm 3 x 2 x fbSP 38mmCondenser water drain field installation

    Power supply Phase / frequency / Voltage Hz / V 3n~ / 50 / 400

  • 36

    ewwd-BjYnn water cooled chiller

    Digital Controller

    StrengtHS › Cooling range: 369–1,050kW › Super high efficiency: EER up to

    5.8 ; A class energy label › Very high EER values at part loads

    condition (ESEER up to 7.4) › 1 and 2 stepless single-screw compressors › optimised for use with R-134a › flooded evaporator › Expansion valve with liquid level control › All models are pED pressure vessel approved

    StanDarD aVailable › main switch › gauges › Electronic expansion valve

    oPtionS (faCtory moUnteD) › glycol application › Suction stop valve › A / V meter › Soft starter › Cu / Ni heat exchanger

    aCCeSSorieS › Communication cards

    (EkAC200J – EkACbAC – EkACloN) › Remote user interface (EkRUpCk) › buffer tanks (EkbT500N - EkbTC10N

    - EkbT500C - EkbTC500C) › Daikin serial sequencing panel (EkDSSp) › modem (EkmoDEm – EkgSmoD) › Converter RS485 to RS232 (EkCoN)

    or to USb (EkCoNUSb)

    s c r e w

  • 37

    ewwDC11bjynn

    Cooling onlyCapacity class 380 460 550 750 850 900 C10 C11Cooling capacity nom. kw 369 445 521 734 816 895 976 1,050 Capacity steps % stepless 25 - 100 Stepless 12.5 - 100Power input Cooling nom. kw 65 77.9 90 129 142 155 167 180 eer 5.68 5.71 5.79 5.65 5.71 5.77 5.81 5.83eSeer 6.44 6.47 6.56 7.16 7.23 7.32 7.37 7.40Dimensions Unit HeightxwidthxDepth mm 2,250x3,625x1,551 2,250x3,860x1,551 2,300x4,145x1,743 2,300x4,145x1,808 2,300x4,145x1,910weight Unit kg 3,089 3,370 3,603 5,546 5,636 6,007 6,448 6,598

    operation weight kg 3,250 3,588 3,870 5,911 6,045 6,460 6,972 7,163water heat exchanger - evaporator

    type flooded shell and tubeminimum water volume in the system l 78 107 134 184 210 281 302water flow rate min. l/min 565 615 776 932 1,216 1,209 1,382 1,632

    nom. l/min 1,058 1,276 1,494 2,104 2,339 2,566 2,798 3,010max. l/min 1,788 1,945 2,455 2,946 3,846 3,825 4,370 5,162

    nominal water pressure drop

    Cooling Heat exchanger

    kPa 35 43 37 51 37 45 41 34

    water heat exchanger - condenser

    minimum water volume in the system l 83 111 133 181 199 243 263water flow rate min. l/min 665 948 1,086 1,478 1,703 1,904 1,924 2,146

    nom. l/min 1,244 1,499 1,752 2,474 2,746 3,010 3,277 3,526max. l/min 2,103 2,998 3,435 4,675 5,386 6,020 6,085 6,786

    nominal water pressure drop

    Heating kPa 35 25 26 28 26 25 29 27

    water heat exchanger - heat recovery condenser type Shell and tubeSound pressure level

    Cooling nom. dba 78 79 80 81 81.5 82 82.5 83

    Compressor type Semi-hermetic single screw compressoroperation range evaporator Cooling min.~max. °CDb -8 ~ 15

    Condenser Cooling min.~max. °CDb 21 ~ 50refrigerant type r-134a

    Charge kg 130 165 180 200 215 230 274 290Control electronic expansion valveCircuits Quantity 1

    Piping connections evaporator water drain 1/2" gasPower supply Phase / frequency / Voltage Hz / V 3~ / 50 / 400

  • 38

    Condenserless ChillerDaikin offers you flexible and compact chillers

    with remote condenser, which can be used to satisfy

    applications with special requirements in the field

    of available space, sound level or extreme operating

    conditions. in these exceptional cases, remote

    condenser solutions can be preferred over standard

    air cooled or water cooled solutions.

    TAblE of CoNTENTS

    ewlP-kbw1n 38

  • 1. Temperature sensor2. filter3. Shut-off valve4. pump5. pressure port6. flow switch7. Drain8. pressure gauge9. Water flow adjusting valve10. Drain valve11. fill valve12. Safety valve

    pIpINg DIAgRAm foR ComfoRT CoolINg ApplICATIoN

    7 6 5 4 5

    3 2

    1

    5 98 103 11

    12

    7

    1

    ChillersGas

    Liquid

    Evap

    orat

    or

    buffer

    tank

    To fan coil

    units

    To condenser

    expan-

    sion

    vessel

  • 40

    ewlP-kBw1n water cooled condenserless chiller

    s c r o l l

    StrengtHS › Daikin scroll compressor › optimised for use with R-407C › Electronic DDC controller › low operating sound level › low energy consumption › Compact dimensions and low refrigerant volume › Easy installation and maintenance › Stainless steel plate heat exchanger › Compatible with hydraulic module › for EWlp012-065kbW1N following components

    are standard included: main switch, pressure ports, flow switch, filter, shut-off valves and air purge

    › µC² SE controller

    oPtionS (faCtory moUnteD) › Chilled water temperature

    down to - 5°C (Zh) or -10°C (Zl)

    aCCeSSorieS (kit) › hydraulic module (see EhmC-page in this catalogue) › low noise operation EUW*5kZW1 (EklS1) › low noise operation EUW*8-24kZW1 (EklS2) › Address card for connection to bmS or

    remote user interface (EkRUmCA) › Remote installed user interface (EkAC10C)

    Control › microprocessor control › Water inlet temperature control

    aVailable inPUtS / oUtPUtSinput › Remote oN / off › pump contact

    output › Compressor operation › Summary alarm › pump relay contact

    µC 2 Se

  • ewlP012-030kbw1n

    Cooling onlyCaPaCity ClaSS 012 020 026 030 040 055 065

    Capacity Cooling kw 12.1 20.0 26.8 31.2 40.0 53.7 62.4Power input Cooling kw 4.2 6.6 8.5 10.1 13.4 17.8 20.3Capacity Steps 1 2eer 2.88 3.03 3.15 3.09 2.99 3.02 3.07Dimensions Height x width x Depth mm 600 x 600 x 600 600 x 600 x 1,200weight machine weight kg 108 141 147 151 252 265 274water Heat exchanger evaporator

    type brased plateminimum water volume in the system l 62 103 134 155 205 268 311water flow rate

    min l/min 17 29 38 45 57 77 89nominal l/min 35 57 77 89 115 154 179max l/min 69 115 153 179 229 307 358

    Compressor type Hermetically sealed scroll compressormodel Quantity 1 2

    Sound Power Cooling dba 64 71 67 74operation range evaporator min~max °CDb -10(oPzl) ~ 20

    Condensing temperature min~max °CDb 25 ~ 60refrigerant circuit refrigerant type r-407C

    no of circuits 1 2refrigerant control thermostatic expansion valve

    Power Supply 3n~/400V/50HzPiping connections evaporator water inlet/outlet mm fbSP 25 fbSP 40

    evaporator water drain field installationliquid line connection mm 9.52 flare 12.7 flare 2x12.7 flareDischarge line connection mm 12.7 flare 19.1 flare 2x19.1 flare

    41

  • 42

    dicn

    Daikin chillers can be equipped with Daikin Integrated

    Chiller Network (DICN) which allows the simultaneous

    operation of up to 4 chillers as if they were a single

    unit, in order to deliver the required cooling capacity.

    This results in precise and efficient capacity control

    and is also useful for back up purposes, ensuring that

    the necessary amount of cooling is available and

    guaranteeing reliable operation of the chiller plant.

    This function enables a Daikin 2mW chiller plant to be

    operated via a single controller. please note that DICN is

    only possible within the same series.

    aPPliCable SerieS: › EWAq080-260DAyN (R-410A) › EWyq080-250DAyN (R-410A)

    Daikin integrated Chiller network

  • 43

    eHMc, ekBt Hydraulic module, buffer tank

    mH2O

    55

    50

    45

    40

    35

    30

    25

    20

    15

    10

    5

    00 20 40 60 80 100 120 140 160 180 200 220 240 260 WF (l/min)

    Water flow

    PUmP CHaraCteriStiCS

    StrengtHS › 100l buffer tank › freeze-up protection (heater tape) › Single pump › 12l expansion vessel › Standard dual pressure ports

    legenDS

    Pump characteristics

    1. EhmC30AV10802. EhmC10AV1080 &

    EhmC15AV10803. EhmC30AV10104. EhmC10AV1010 &

    EhmC15AV1010

    Hydraulic module + filter pressures losses

    5. EhmC15/30AV1010 & EhmC15/30AV1080

    6. EhmC10AV1010 & EhmC10AV1080

    Hydraulic moduleeHmC-aV

    10 15 30

    1010 1080 1010 1080 1010 1080

    nominal flow l/min 62 88 187nominal static height mH2o 17 34 15 27 10 27nominal input w 630 1,050 650 1,070 1,070 2,090Dimensions (HxwxD) mm 1,284x635x688machine weight kg 99 101 102 104 105 111Sound power dba 63Sound pressure dba 52Power supply V1 1~/230V/50Hzoperation range water side °C -10°C ~ 55°C

    air side °CDb -10°C ~ 43°CPiping connections water inlet/outlet 1" bSPf 2" bSPf 2-1/2" bSPf

    Drain connection 1/2"

    buffer tankMODEL Description Volume Dimensions Unit weight

    ekbt buffer tank with cabinet 200l 1,284x637x754 86,5

    ekbt500n buffer tank 500l 710x1,670 70

    ekbtC10n buffer tank 1,000l 860x2,020 100

    ekbt500C buffer tank with cabinet 500l 1,200x1,200x1,950 160

    ekbtC10C buffer tank with cabinet 1,000l 1,200x1,450x1,950 185

  • 44

    fan Coil Unitsfan Coil Units are a highly efficient means of turning

    a water chiller, heat pump or hot water boiler into an efficient,

    quiet air conditioning system. these units are an effective

    solution to provide a comfortable environment for both

    commercial and residential applications.

    Daikin offers a wide range of fan Coil Units for both concealed

    and exposed applications.three models are available in flexible

    application. the only moving part in the units is the fan,

    making them ideal for use in offices, hotels and at home.the

    goal is to obtain the right solution, both technically

    and aesthetically.

    fan Coil Unit - aCCeSSorieS 44

    fan Coil Unit - Control 46

    fwV-Dt/Df 48

    fwl-Dt/Df 49

    fwm-Dt/Df 50

    fwD-at/af 51

    fwt-bt 52

    fwb-bt 53

    fwb-jt/jf 54

    fwC -bt/bf 55

    fwf-bt/bf 56

    TAblE of CoNTENTS

  • 45

    02

    02 03 04 06 07 08

    05 06 07 08 09 1110

    02 03 04 06 10

    03 04 05 06 08 09 10 11

    02 03 05

    02 03 04 05 06

    03 04

    02 03

    06 07 08 09

    06 07 08

    0706 09

    06 07 08 09

    02 03 06 08 10

    01 02 03 04 06 08 10

    02 03 06 08 10

    02 03 0406 08

    02 03 06 08 10

    01 02

    02

    03

    03

    03

    03

    04

    07

    07

    07

    02

    02

    03

    06

    06

    06

    01

    02

    02

    04

    04

    04 06 08 10 12 16 18

    08 10 12 16 18

    03

    03

    03

    08 10 12

    04

    04

    04

    1816

    02

    05

    05

    05

    03

    03

    04

    04

    04

    0604

    06

    08

    08

    09

    04

    0604

    06

    06

    06

    08

    08

    09

    09

    10

    06

    08

    08

    08

    08

    10

    10

    10

    10

    10

    10

    08 10

    10

    12

    0607

    050910

    08

    09

    04 06

    08

    04

    02

    04

    04

    10

    04

    1002

    18

    16

    measuring conditions (at nominal air flow and ESp) : CoolINg • air temperature entering the unit: 27°C/19°C • water temperature entering the unit 7°C • leaving the unit 12°C hEATINg • room air temperature 20°C • for 2 pipe units : water temperature entering 50°C - water flow rate same as for the cooling test • for 4 pipe units : water temperature entering 70°C - water temperature leaving 60°C.* 4-pipe= 2-pipe + option additional heat exchanger

    pRoDUCT poRTfolIo

    0202

    01

    01

    01

    01

    01

    01

    07 08

    02 07

    10

    03

    08

    100604

    06

    06

    02

    0403

    02 08

    Reference

    FWT-

    BT

    2-pipecooling

    heating

    FWC-

    BT/B

    F 2-pipecooling

    heating

    4-pipecooling

    heating

    FWF-

    BT/B

    F 2-pipecooling

    heating

    4-pipecooling

    heating

    FWV-

    DT/

    DF 2-pipe

    cooling

    heating

    4-pipecooling

    heating

    FWL-

    DT/

    DF 2-pipe

    cooling

    heating

    4-pipecooling

    heating

    FWM

    -DT/

    DF 2-pipe

    cooling

    heating

    4-pipecooling

    heating

    FWB

    -BT

    2-pipecooling

    heating

    4-pipe*cooling

    heating

    FWD

    -AT/

    AF 2-pipe

    cooling

    heating

    4-pipecooling

    heating

    FWB

    -JT/

    JF

    2-pipecooling

    heating

    4-pipecooling

    heating (4-pipe)

    05

    05

    02 0304 05

    03 0402 05

    01

    04

    1 2 3 4 5 6 7 8 9 10 11 12 16 18 20 22kW

    01

    01

  • 46

    fAn coil unit - AcceSSorieS

    tyPefwt fwC-bt/bf fwf-bt/bf

    Description

    Standard wired remote control merCa - -

    Simplified wired remote control SrC-Cob - -

    Simplified wired remote control SrC-HPb - -

    wireless control for cooling only wrC-Cob - -

    wireless control for heat pump wrC-HPb - -

    Decoration Panel (ral 9010 - grey sealings) 4-way blow - - byfQ60b

    Decoration Panel - Standard (ral 9010 - grey sealings) round flow

    - byCQ140Cw1

    Decoration Panel - white (ral 9010 - white sealings) round flow

    - byCQ140Cw1w

    Sealing member of air dis-charge outlet - kDbHQ55C140 kDbH44ba60

    Panel spacer - - kDbQ44b60

    long-life filter - kafP551k160 kafQ441ba60

    fresh air intake kit - Direct installation type - - kDDQ44Xa60

    fresh air intake kit (20% fresh air) - Direct installation type -

    kDDQ55C140-1 (*20) /

    kDDQ55C140-2 (*20)

    -

    remote controller - wireless - H/P - brC7f532f (*18) brC7e530 (*18)

    remote controller - wireless - C/o - brC7f533f (*18) brC7e531 (*18)

    remote controller - wired - brC315D7 (*4)

    Central remote controller - DCS302Ca51 (*5)

    electrical box with earth terminal (3 blocks) - kjb311a

    Unified on/off controller - DCS301ba51 (*9)

    electrical box with earth terminal (2 blocks) - kjb212a

    Schedule timer - DSt301ba51 (*6)(*9)DSt301ba51

    (*6)(*9)wiring adapter for electrical appendices (1) -

    krP2a52 (*7) (*12)

    krP2a52 (*9) (*12)

    wiring adapter for electrical appendices (2) -

    krP4aa53 (*7) (*12)

    krP4aa53 (*9) (*12)

    installation box for adapter PCb - krP1H98 (*13) krP1ba101 (*17)

    remote sensor - krCS01-4 krCS01-1

    intelligent touch controller - DCS601C51C(*6) (*11)DCS601C51C (*6)

    (*11)

    electrical installation box - kjb411a

    optional PCb for moD-bus connection -

    ekfCmbCb7 (*8) (*12)

    ekfCmbCb7 (*8) (*12)

    2-way valve - on/off - ekmV2C09b7 (*8) (*10) (*15)ekmV2C09b7 (*8) (*10) (*16)

    3-way valve - on/off - ekmV3C09b7 (*8) (*10) (*15)ekmV3C09b7 (*8) (*10) (*16)

    Valve control PCb - ekrP1C11

    remote “on/off” and “forced off” kit - ekroroa (*17)

    type: fwm-Dt/Df, fwl-Dt/Df, fwV-Dt/Df 1 2 3 4 6 8 10 fwV fwl fwMDescriptionadditional single row heat exchanger eSrH02a6 eSrH03a6 eSrH06a6 eSrH10a6 x x x

    electric heater eeH01a6 eeH02a6 eeH03a6 eeH06a6 eeH10a6 x x x2-pipe 3-way valve e2mV03a6 e2mV06a6 e2mV10a6 x x x4-pipe 3-way valve e4mV03a6 e4mV06a6 e4mV10a6 x x xfan stop thermostat yfSta6 x x xair intake & discharge grille eaiDf02a6 eaiDf03a6 eaiDf06a6 eaiDf10a6 - - xSupporting feet eSfV06a6 eSfV10a6 x - xSupporting feet + grille eSfVg2a6 eSfVg3a6 eSfVg6a6 eSfVg10a6 x - -fresh air intake efa2a6 efa3a6 efa6a6 efa10a6 x - -rear panel erPV2a6 erPV3a6 erPV6a6 erPV10a6 x x -Control electromechanical eCfwmb6 x x xelectronic controller fweC1a, fweC2a, fweC3a x x xmaster slave option ePimSb6 x x xVertical drainpan eDPVa6 x x xHorizontal drainpan eDPHa6 - x xon board installation kit fweCka x x -temperature sensor kit fwtSka x x xrelative humidity sensor kit fwHSka x x xon board fCU controller installation kit fweCka x x -

    1. requires electronic controller2. for fwD 12,16,18at/af only motor valve (piping not included)3. water probe included4. optional, electrical installation box with earth terminal kjb212a is required, if controller wires need to be installed

    in the wall.5. requires electrical installation box with earth terminal kjb311a.6. requires electrical installation box kjb411a.7. requires installation box krP1H98. (fwC)8. requires installation box krP1ba101 (fwf)9. requires electrical installation box with earth terminal kjb212a, if built in the wall.10. requires valve control PCb ekrP1C1111. i-touch:

    • not allowed to


Recommended