Getting Started 1 Attach Probe at the base front of the system. Probe cable extends out to the right. 2 Turn on system. The power switch is located on the left hand side 3 Press New Patient, enter name and ID number Press ID to exit 4 Press Preset, Trackball to desired Preset, press Set 5 Press Probe, Trackball to desired Probe, press Set Brightness Turn B Gain Knob: Clockwise: Brighter Counter-Clockwise: Darker Depth For a smaller image and more depth: Press For a larger image and less depth: Press Freeze Freezes the image. Press again to unfreeze. Measure Press Freeze Press the Caliper key, move with trackball. Press Mark Ref to anchor the starting point. Trackball to end point of measurement. Number appears in box. Measure (continued) To take another measurement, press the Caliper key again and repeat procedure. Press Freeze again to erase measurement box. STC Slide Pots Individual gain controls. Used to fine-tune overall gain at specific depth. Start with all in middle position then adjust as needed. New Patient Probe Brightness Freeze Calipers Comment ID Zoom Trackball Focus Menu Depth/Range Print ALOKA PROSOUND ALPHA 5 ULTRASOUND SYSTEM QUICK REFERENCE GUIDE Set Preset Mark Ref
Transcript
Page 1: Alpha 5 QRG - mercyor.files.wordpress.com · ALOKA PROSOUND ALPHA 5 ULTRASOUND SYSTEM QUICK REFERENCE GUIDE Set Preset Mark Ref. CONSOLE FUNCTIONS Invert Flips the image orientation

Getting Started

1 Attach Probe at the base front of the system. Probe cable extends out to the right.

2 Turn on system. The power switch is located on the left hand side

3 Press New Patient, enter name and ID number

Press ID to exit

4 Press Preset, Trackball to desired Preset, press Set

5 Press Probe, Trackball to desired Probe, press Set

Brightness Turn B Gain Knob: Clockwise: Brighter Counter-Clockwise: Darker

Depth For a smaller image and more depth: Press

For a larger image and less depth: Press

Freeze Freezes the image. Press again to unfreeze.

Measure

Press Freeze

Press the Caliper key, move with trackball.

Press Mark Ref to anchor the starting point.

Trackball to end point of measurement. Number appears in box.

Measure (continued) To take another measurement,

press the Caliper key again and repeat procedure.

Press Freeze again to erase measurement box.

STC Slide Pots Individual gain controls. Used to fine-tune overall gain at specific depth.

Start with all in middle position then adjust as needed.

New Patient Probe

Brightness

Freeze

Calipers

CommentID

Zoom

Trackball

Focus

Menu

Depth/Range

Print

ALOKA PROSOUND ALPHA 5 ULTRASOUND SYSTEMQUICK REFERENCE GUIDE

Set

Preset

Mark Ref

Page 2: Alpha 5 QRG - mercyor.files.wordpress.com · ALOKA PROSOUND ALPHA 5 ULTRASOUND SYSTEM QUICK REFERENCE GUIDE Set Preset Mark Ref. CONSOLE FUNCTIONS Invert Flips the image orientation

CONSOLE FUNCTIONS

Invert Flips the image orientation

Imaging Modes Split image: Press

Single image: Press

M-Mode Full screen M-MODE: Press

Split Image and M-MODE: Press

Doppler Full screen Doppler: Press

Split Image and Doppler: Press

Comments On the lower left keyboard, Press Comment; move cursor to desired position with trackball. Type comment using keys. Backspace key

Return key

Press Comment to exit

Focus Press Focus key.

Use trackball to move focal point. Keep focus at area of interest.

Zoom Press Zoom key.

Use Rotary Knob to enlarge image. Use Trackball to move zoomed area around the screen.

Press Zoom key to turn off.

Print Image Press Freeze. Then press Print key

Store Image Press Freeze. Then press Store key

To Review Stored Images

Press Freeze, Press Review

Trackball to ALL WINDOW and press Set

Double click one image to enlarge. Trackball to Next, Prev, or RETURN.

Press Review to exit