+ All Categories
Home > Documents > Alpha Vci.10 - ACM System - ECO Cladding Vci.10- ACM... · 2016-12-22 · 8.ACM panel system 9.A/V...

Alpha Vci.10 - ACM System - ECO Cladding Vci.10- ACM... · 2016-12-22 · 8.ACM panel system 9.A/V...

Date post: 07-Jun-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
12
Page: Revision: 09/2016 01 Alpha Vci.10 - ACM System www.ecocladding.com
Transcript
Page 1: Alpha Vci.10 - ACM System - ECO Cladding Vci.10- ACM... · 2016-12-22 · 8.ACM panel system 9.A/V barrier 10.Exterior wall 11.ACM coping 12.Window sill D - System depth t - ACM panel

Page:Revision: 09/2016 01

Alpha Vci.10 - ACM System

www.ecocladding.com

Page 2: Alpha Vci.10 - ACM System - ECO Cladding Vci.10- ACM... · 2016-12-22 · 8.ACM panel system 9.A/V barrier 10.Exterior wall 11.ACM coping 12.Window sill D - System depth t - ACM panel

Page:Revision: 09/2016 02

Elevation and floor plan

www.ecocladding.com

Outer corner

pg.06

Inner corner

pg.07

Window jamb

pg.08

Vertical joint

pg.04

Ba

se

d

eta

il

pg

.1

2

Cop

in

g de

ta

il

pg.1

1

Ho

rizo

nta

l jo

int

pg

.0

5

Win

do

w sill

pg

.1

0

Win

do

w he

ad

pg.09

Page 3: Alpha Vci.10 - ACM System - ECO Cladding Vci.10- ACM... · 2016-12-22 · 8.ACM panel system 9.A/V barrier 10.Exterior wall 11.ACM coping 12.Window sill D - System depth t - ACM panel

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. Vertical L-profile

7. Insulation

8. ACM panel system

9. A/V barrier

10. Exterior wall

11. ACM coping

12. Window sill

D - System depth

t - ACM panel system thickness

* Ventilation will vary based on insulation

depth.

** Minimum ventilation requirement should

be qualified by panel manufacturer.

System depth

Bracket

min. D system depth max. D system depth t panel thickness

Alpha V 035 / Alpha V+ 035

1

13

16

" (47mm) 2

15

16

" (75mm)

varies

Alpha V 050 / Alpha V+ 050

2

1

16

" (53mm) 3

9

16

" (90mm)

varies

Alpha V 080 / Alpha V+ 080

3

1

4

" (83mm) 4

3

4

" (120mm)

varies

Alpha V 100 / Alpha V+ 100

4

1

16

" (103mm) 5

1

2

" (140mm)

varies

Alpha V 115 / Alpha V+ 115

4

5

8

" (118mm) 6

1

8

" (155mm)

varies

Alpha V 135 / Alpha V+ 135

5

7

16

" (138mm) 6

7

8

" (175mm)

varies

Alpha V 150 / Alpha V+ 150 6" (153mm)

7

1

2

" (190mm)

varies

Alpha V 170 / Alpha V+ 170

6

13

16

" (173mm) 8

1

4

" (210mm)

varies

Alpha V 185 / Alpha V+ 185

7

3

8

" (188mm) 8

7

8

" (225mm)

varies

Alpha V 200 / Alpha V+ 200 8" (203mm)

9

1

2

" (240mm)

varies

Alpha V 220 / Alpha V+ 220

8

3

4

" (223mm) 10

1

4

" (260mm)

varies

Alpha V 255 / Alpha V+ 255

10

3

16

" (258mm) 11

5

8

" (295mm)

varies

tD

2 3/4 5 6 8 9 1017

Page:Revision: 09/2016 03

System depth

www.ecocladding.com

Page 4: Alpha Vci.10 - ACM System - ECO Cladding Vci.10- ACM... · 2016-12-22 · 8.ACM panel system 9.A/V barrier 10.Exterior wall 11.ACM coping 12.Window sill D - System depth t - ACM panel

tD

2 3/4 5 68 9 1017

per manufacturer requirements

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. Vertical L-profile

7. Insulation

8. ACM panel system

9. A/V barrier

10. Exterior wall

11. ACM coping

12. Window sill

D - System depth

t - ACM panel system thickness

* Ventilation will vary based on insulation

depth.

** Minimum ventilation requirement should

be qualified by panel manufacturer.

Page:Revision: 09/2016 04

Vertical joint

www.ecocladding.com

Page 5: Alpha Vci.10 - ACM System - ECO Cladding Vci.10- ACM... · 2016-12-22 · 8.ACM panel system 9.A/V barrier 10.Exterior wall 11.ACM coping 12.Window sill D - System depth t - ACM panel

per m

anufacturer requirem

ents

4

5

2

6

7

9

10

8

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. Vertical L-profile

7. Insulation

8. ACM panel system

9. A/V barrier

10. Exterior wall

11. ACM coping

12. Window sill

D - System depth

t - ACM panel system thickness

* Ventilation will vary based on insulation

depth.

** Minimum ventilation requirement should

be qualified by panel manufacturer.

Page:Revision: 09/2016 05

Horizontal joint

www.ecocladding.com

Page 6: Alpha Vci.10 - ACM System - ECO Cladding Vci.10- ACM... · 2016-12-22 · 8.ACM panel system 9.A/V barrier 10.Exterior wall 11.ACM coping 12.Window sill D - System depth t - ACM panel

D t

2 3/4 5 6 8910 17

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. Vertical L-profile

7. Insulation

8. ACM panel system

9. A/V barrier

10. Exterior wall

11. ACM coping

12. Window sill

D - System depth

t - ACM panel system thickness

* Ventilation will vary based on insulation

depth.

** Minimum ventilation requirement should

be qualified by panel manufacturer.

Page:Revision: 09/2016 06

Outer corner

www.ecocladding.com

Page 7: Alpha Vci.10 - ACM System - ECO Cladding Vci.10- ACM... · 2016-12-22 · 8.ACM panel system 9.A/V barrier 10.Exterior wall 11.ACM coping 12.Window sill D - System depth t - ACM panel

D t

9101523/46 78

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. Vertical L-profile

7. Insulation

8. ACM panel system

9. A/V barrier

10. Exterior wall

11. ACM coping

12. Window sill

D - System depth

t - ACM panel system thickness

* Ventilation will vary based on insulation

depth.

** Minimum ventilation requirement should

be qualified by panel manufacturer.

Page:Revision: 09/2016 07

Inner corner

www.ecocladding.com

Page 8: Alpha Vci.10 - ACM System - ECO Cladding Vci.10- ACM... · 2016-12-22 · 8.ACM panel system 9.A/V barrier 10.Exterior wall 11.ACM coping 12.Window sill D - System depth t - ACM panel

tD

9 10 1 2 6 5 8

2

7

3/4

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. Vertical L-profile

7. Insulation

8. ACM panel system

9. A/V barrier

10. Exterior wall

11. ACM coping

12. Window sill

D - System depth

t - ACM panel system thickness

* Ventilation will vary based on insulation

depth.

** Minimum ventilation requirement should

be qualified by panel manufacturer.

Page:Revision: 09/2016 08

Window jamb

www.ecocladding.com

Page 9: Alpha Vci.10 - ACM System - ECO Cladding Vci.10- ACM... · 2016-12-22 · 8.ACM panel system 9.A/V barrier 10.Exterior wall 11.ACM coping 12.Window sill D - System depth t - ACM panel

Dt

8

3

5

2

6

7

9

10

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. Vertical L-profile

7. Insulation

8. ACM panel system

9. A/V barrier

10. Exterior wall

11. ACM coping

12. Window sill

D - System depth

t - ACM panel system thickness

* Ventilation will vary based on insulation

depth.

** Minimum ventilation requirement should

be qualified by panel manufacturer.

Page:Revision: 09/2016 09

Window head

www.ecocladding.com

Page 10: Alpha Vci.10 - ACM System - ECO Cladding Vci.10- ACM... · 2016-12-22 · 8.ACM panel system 9.A/V barrier 10.Exterior wall 11.ACM coping 12.Window sill D - System depth t - ACM panel

Dt

8

3

5

2

6

7

9

10

12

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. Vertical L-profile

7. Insulation

8. ACM panel system

9. A/V barrier

10. Exterior wall

11. ACM coping

12. Window sill

D - System depth

t - ACM panel system thickness

* Ventilation will vary based on insulation

depth.

** Minimum ventilation requirement should

be qualified by panel manufacturer.

Page:Revision: 09/2016 10

Window sill

www.ecocladding.com

Page 11: Alpha Vci.10 - ACM System - ECO Cladding Vci.10- ACM... · 2016-12-22 · 8.ACM panel system 9.A/V barrier 10.Exterior wall 11.ACM coping 12.Window sill D - System depth t - ACM panel

Dt

8

pe

r m

an

ufa

ctu

re

r re

qu

ire

me

nts

3

5

2

6

7

9

10

11

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. Vertical L-profile

7. Insulation

8. ACM panel system

9. A/V barrier

10. Exterior wall

11. ACM coping

12. Window sill

D - System depth

t - ACM panel system thickness

* Ventilation will vary based on insulation

depth.

** Minimum ventilation requirement should

be qualified by panel manufacturer.

Page:Revision: 09/2016 11

Coping detail

www.ecocladding.com

Page 12: Alpha Vci.10 - ACM System - ECO Cladding Vci.10- ACM... · 2016-12-22 · 8.ACM panel system 9.A/V barrier 10.Exterior wall 11.ACM coping 12.Window sill D - System depth t - ACM panel

Dt

8

3

5

2

6

7

9

10

Legend

1. Steel stud (16 GA typical)

2. Perimeter anchor

3. Alpha V wall bracket

4. Alpha V+ wall bracket

5. st/st self-drilling screw

3

16

"x

3

4

"

6. Vertical L-profile

7. Insulation

8. ACM panel system

9. A/V barrier

10. Exterior wall

11. ACM coping

12. Window sill

D - System depth

t - ACM panel system thickness

* Ventilation will vary based on insulation

depth.

** Minimum ventilation requirement should

be qualified by panel manufacturer.

Page:Revision: 09/2016 12

Base detail

www.ecocladding.com


Recommended