Series “AFX”
G
GE
A
2 Passes 4 Passes 6 Passes
F
CLF
45°
F
F F
AGG
G
F
GG
1/2" NPT
3/4" NPT G
30
C
B
1/2" NPTVENT
VENT
1/2" NPT
H
H
CE
CLF
G
VENT1/2" NPT
CE
B
Bonnet Head "A"
Bonnet Head "B"
Channel Head "C"
H
H
CL
CL
Tube bundle immersion length
Nominal shell diameter
Number of tube passes" AFX " Series
Connections Flanged or Couplings
AFX-2-6-36-A-F
Type of head
Complete model numberas per the following example:
OptionalExpansionJoint
B
OptionalExpansionJoint
OPTIONALEXPANSIONJOINT
G
H
H
G
CL
Carbon Steel, Stainless Steel
Head Carbon Steel, Stainless Steel, Cast Iron
Shell Tube
Tubes O.D.1/2", 5/8", 3/4" Copper, Stainless Steel, Carbon Steel
150 psi @ 400 F
150 psi @ 400 F
DesignPressure &Temperature
Shell
Tubesheet
Carbon Steel, Stainless Steel
Side Standard Customized
D
D
D
To have the capacity to heat__________gpm of _________________ in the ____________
from________F to ________F using_____________________________, entering at__________
Unit to be constructred in accordance with ASME requirements . ASME Stamp is ( not ) required.
Unit to have no more than _____ ft. of length and ____ psi pressure drop in the shell and _____psi in the tubes.
Service water heatingProcess heat transfer
Typical Applications
Mechanical cleaning inside the tubesLimited to applications with smalltemperature difference
* - Various materials and working conditions can be provided. - Legs can be supplied when specified. - Space equal to or greater than dimension "B" should be provided for removal of tube bundle.
* - All Heat Exchangers are designed and manufactured according to ASME Code, Section VIII, Div.1. ASME U-1 Form, Stamp, and N.B. Number are provided upon request for an additional cost.
* - All heaters have a one year guarantee against failure caused by materials or workmanship, but not against gasket failure or damage caused by corrosion, water hammer, fouling, sealing, excessive pressure or temperature, incorrect installation or other factor beyond the manufacturer's control.
1408 Seabury Ave. Bronx, NY 10461 tel 718.824.4901 fax 718.409.3605 • alstromcorp.com
C
M
Y
CM
MY
CY
CMY
K
BLUE_AFX.pdf 1/10/05 12:17:47 PMBLUE_AFX.pdf 1/10/05 12:17:47 PM
Alstrom Straight Tube & Fixed Tubesheet
6 PASS 6 PASS
Series “AFX”
B
C
WGT
B
C
WGT
B
C
WGT
B
C
WGT
B
C
WGT
B
C
WGT
B
C
WGT
B
C
WGT
B
C
WGT
*-4-**
AFX
*-5-**
*-6**
*-8-**
*-10-**
*-12-**
*-14-**
*-16-**
WGT
B
C
WGT
*-18-**
*-20-**
*-24-**
Dimension Table
**24 **30 **36 **42 **48 **54 **60 **66 **72 **78 **84 **90 **96 **108 **120
31 37 43 49 55 61 67 73 79 85 91 97 103
21 27 33 39 45 51 57 63 69 75 81 87 93
68 75 83 90 96 104 112 119 127 134 141 148 156
32
20
100
38
26
115
44
32
130
50
38
145
56
44
160
62
50
175
68
56
190
74
62
205
80
68
220
86
74
235
92
80
250
98
86
265
104
92
280
20 26 32 38 44 50 56 62 68 74 80 86 92
134 148 162 176 190 204 218 233 248 261 276 290 305
32
18
190
38
24
222
44
30
250
50
36
277
56
42
305
62
48
333
68
54
360
74
60
388
80
66
416
86
72
444
92
78
472
98
84
500
104
90
527
34
20
320
40
26
348
46
32
377
52
38
404
58
44
432
64
50
459
70
56
487
76
62
515
82
68
544
88
76
571
94
80
599
100
86
626
106
92
653
118
104
710
161
140
900
34
18
417
40
24
453
46
30
490
52
36
527
58
42
564
64
48
601
70
54
638
76
60
675
82
66
714
88
72
751
94
78
788
100
84
825
106
90
862
118
102
937
154
138
1160
46
17
660
52
23
704
58
29
748
64
35
791
70
41
835
76
47
879
82
53
923
88
59
967
94
65
1014
100
71
105 8
106
77
1102
112
83
1146
118
89
1190
130
101
1282
166
137
1700
48
16
819
54
22
874
60
28
929
66
34
984
72
40
1040
78
46
1096
84
52
1152
90
58
120 7
96
64
1271
102
70
132 7
108
76
138 3
114
82
1438
120
88
149 4
132
100
1614
168
136
1950
50
16
1055
56
22
1130
62
28
120 5
68
34
1280
74
40
1356
80
46
1431
86
52
1506
92
58
1582
98
64
1662
104
70
174 2
110
76
1818
116
82
1893
122
88
196 8
134
100
2130
170
112
2580
1258 1357 1456 1555 1654 1753 1852 1951 2062 2161 2260 2359 2458 2670 3270
52
14
1450
58
20
1560
64
26
1650
70
32
1750
76
38
1850
82
44
1950
88
50
2050
94
56
2150
100
62
226 0
106
68
236 0
112
74
2460
118
80
2560
124
86
266 0
136
98
2870
172
134
3470
32 38 44 50 56 62 68 74 80 86 92 98 104
50
16
56
22
62
28
68
34
74
40
80
46
86
52
92
58
98
64
104
70
110
76
116
82
122
88
134
100
170
136
115 151
105 141
116 152
104 140
116 152
104 140
116 152
102 138
172 220
210 300
440 530
590 770
B
C
Customized Connections
Dimensions in inches Weight in pounds
137
116
766
130
114
1010
142
113
1420
144
112
1725
146
112
2280
2870
148
110
3070
146
112
127
117
128
116
128
116
128
114
188
240
470
650
**144
A D EF
AFX
*-4-**
*-5-**
*-6-**
*-8-**
*-10-**
7-1/4
7
2 PASS 4 PASSG
H
2-1/2 1-1/4
2 PASS 4 PASS
2-1/2 1
8-1/4
9-1/4
12
15
19
23
25
29
21
6
7
8
9
10
16
18
18
20
22
2-1/2 1-1/42-1/2 1
3-1/4 22-7/8 1-1/2
5 2-1/23-7/8 2
5-7/8 34-1/4 3
6-1/2 4 Flg6-1/4 3
22 5 Flg7 4 Flg 4 Flg
24 6 Flg12 5 Flg 4 Flg
27 8 Flg13 5 Flg
28 8 Flg14 6 Flg
32 10 Flg16 8 Flg
*-12-**
*-14-**
*-16-**
*-18-**
*-20-**
*-24-**
17
4-3/4
7-5/8
9
22
24
26
28
32
3
4 Flg
4 Flg
5 Flg
6 Flg
6
1-1/4
2-1/2
3
2
Head
Types"B"&"C" areoptional
1-1/4
2
2
3
3
3
6 Flg
8 Flg
8 Flg
Type "A"
Types"B"&"C"
Type "A" isoptional
TYPE
SIZE
5-9/164-1/2
6-5/8
8-5/8
10-3/4
12-3/4
14
16
18
20
24
Threaded couplings are according toANSI NPT for sizes up to 3".Flanged connections are optional.For 4" and up the connections areflanged according to ANSI.
Direction and sizes of connections may bespecified by the customer, providing easyassembly of a new system or replacementof an old heat exchanger.
The actual dimensions of a heat exchangerdepend upon its performance and maybe modified during the preparation of working drawings.
1408 Seabury Ave. Bronx, NY 10461 tel 718.824.4901 fax 718.409.3605 • alstromcorp.com
C
M
Y
CM
MY
CY
CMY
K
BLUE_AFX (Rev).pdf 1/10/05 12:19:16 PMBLUE_AFX (Rev).pdf 1/10/05 12:19:16 PM
Straight Tube & Fixed Tubesheet Heat Exchangers