Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Product Line Up
Description : Add In Model and Typing Amendment
Amendment on Manual’s Page No. :
1
Product Line-Up
Outdoor Unit
ALC-C Series
Cap
Tu
be
Go
ld C
oa
ted
Bare
Co
nta
cto
r
Hig
h P
res
su
re S
wit
ch
L
ow
Pre
ssu
re S
wit
ch
S
cro
ll
Ro
tary
CE
Bac
k P
an
el
Gri
lle
S
up
er
Tro
pic
al
Sp
ec
ific
ati
on
ACPOE X X X X
ACPIE X X X X
ACPOD X X X X
ACPID X X X X
ACPOB X X X X
ACPIB X X X X
ACPOD X X X X
ACPID X X X X
ACPOD X X X X
ACPID X X X X
ACPBD X X X X X
ACPOD X X X X
ACPID X X X X
ACPBD X X X X X
ACPHB X X X X X X
ACPOD X X X X
ACPID X X X X
ACPBD X X X X X
ACPHB X X X X X X
ACHOB X X X
ACHIB X X X
ACHBB X X X X
30C AFGE X X X X X X
P
CB
CO
OL
ING
ALC
10C
15C
18C
20C
28C
F
IN
No
me
nc
latu
re
Classification
M
ark
ing
O
the
rs
S
pec
ial
07C
S
afe
ty D
ev
ice
s
C
om
pre
ss
or
R
efr
ige
ran
t
C
on
tro
l
09C
25C
5
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Product Line Up
Description : Add In Model and Typing Amendment
Amendment on Manual’s Page No. :
2
Outdoor Unit
ALC-CR Series
C
ap
Tu
be
T
XV
G
old
Co
ate
d
B
are
C
on
tac
tor
H
igh
Pre
ss
ure
Sw
itch
Lo
w P
res
su
re S
wit
ch
Sc
roll
R
ota
ry
C
E
D
rain
Elb
ow
S
up
er
Tro
pic
al
Sp
ecif
icati
on
ACPOD X X X X
ACPID X X X X
ACPOB X X X X
ACPIB X X X X
ACPOA X X X X
ACPIA X X X X
ACPOD X X X X
ACPID X X X X
ACPOD X X X X
ACPID X X X X
ACPHB X X X X X
ACPOD X X X X
ACPID X X X X
ACPHB X X X X X
ACHOB X X X X
ACHIB X X X X
30CR AFFB X X X X X X X X
ALC
No
me
ncla
ture
Classification
P
CB
R
efr
ige
ran
t
C
on
tro
l
F
IN
S
afe
ty D
ev
ice
s
C
om
pre
ss
or
M
ark
ing
O
thers
S
pe
cia
l
HE
AT
PU
MP
09CR
10CR
15CR
18CR
20CR
25CR
28CR
6
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Refrigerant Diagram
Description : Amendment In Refrigerant Diagram For AWM301 - ALC28C
Amendment on Manual’s Page No. :
3
Refrigerant Circuit Diagram
Model: AWM301 – ALC28C
12
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Refrigerant Diagram
Description : Add In Refrigerant Diagram For AWM301/R - ALC28C/CR
Amendment on Manual’s Page No. : NIL
4
Model: AWM301 – ALC30C
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Refrigerant Diagram
Description : Add In Refrigerant Diagram For AWM301/R – ALC30C/CR
Amendment on Manual’s Page No. :
5
Model: AWM301R –ALC30CR
NIL
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Engineering And Physical Data
Description : Amendment On Engineering And Physical Data
Amendment on Manual’s Page No. :
6
Engineering & Physical Data
General Data - Cooling Only (R22)
AWM - 20G AWM - 20G
ALC - 18C ALC - 20C
Btu/h 18000 19000
W 5280 5570
W 1820 1807
A 8.10 8.00
V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
W/W 2.90 3.08
R22 R22
OUTDOOR CAP. TUBE OUTDOOR CAP. TUBE
DOUBLE LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
DOUBLE LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
LCD REMOTE CONTROL LCD REMOTE CONTROL
l/s / CFM 231 / 490 231 / 490
l/s / CFM 193 / 410 193 / 410
l/s / CFM 160 / 340 160 / 340
dBA 43 / 40 / 35 43 / 40 / 35
mm/in 304 / 12.0 304 / 12.0
mm/in 1062 / 41.8 1062 / 41.8
mm/in 222 / 8.7 222 / 8.7
mm/in 378 / 14.9 378 / 14.9
mm/in 1130 / 44.5 1130 / 44.5
mm/in 292 / 11.5 292 / 11.5
kg/lb 16 / 35.3 16 / 35.3
mm/in 20 / 0.8 20 / 0.8
l/s / CFM 614 / 1300 614 / 1300
dBA 51 51
mm/in 654 / 25.7 654 / 25.7
mm/in 855 / 33.7 855 / 33.7
mm/in 328 / 12.9 328 / 12.9
mm/in 710 / 28.0 710 / 28.0
mm/in 990 / 39.0 990 / 39.0
mm/in 415 / 16.3 415 / 16.3
kg/lb 58 / 127.9 59 / 130.1
FLARE VALVE FLARE VALVE
LIQUID mm/in 6.35 / 1/4 6.35 / 1/4
GAS mm/in 15.88 / 5/8 15.88 / 5/8
kg/lb 0.80 / 1.76 1.35 / 2.981) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
REFRIGERANT CHARGE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
CONDENSATE DRAIN SIZE
MEDIUM
LOW
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
POWER SOURCE
EER
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
IND
OO
R U
NIT
CONTROLAIR DISCHARGE
OPERATION
AIR FLOW
HIGH
MODELINDOOR UNIT
OUTDOOR UNIT
NOMINAL CAPACITY
NOMINAL TOTAL INPUT POWER
NOMINAL RUNNING CURRENT
37
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Engineering And Physical Data
Description : Amendment On Engineering And Physical Data
Amendment on Manual’s Page No. :
7
General Data - Cooling Only (R22)
AWM - 25G AWM - 301
ALC - 25C ALC - 28C
Btu/h 23500 27000
W 6890 7913
W 2530 2708
A 11.30 13.10
V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
W/W 2.72 3.00
R22 R22
OUTDOOR CAP. TUBE EXTERNAL ORIFICE KIT
DOUBLE LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
AUTO LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
LCD REMOTE CONTROL LCD REMOTE CONTROL
l/s / CFM 297 / 630 316 / 670
l/s / CFM 231 / 490 297 / 630
l/s / CFM 208 / 440 236 / 500
dBA 49 / 44 / 42 49 / 47 / 45
mm/in 304 / 12.0 360 / 14.2
mm/in 1062 / 41.8 1200 / 47.2
mm/in 222 / 8.7 200 / 7.9
mm/in 378 / 14.9 420 / 16.5
mm/in 1130 / 44.5 1267 / 49.9
mm/in 292 / 11.5 260 / 10.2
kg/lb 16 / 35.3 17 / 37.48
mm/in 20 / 0.8 20 / 0.8
l/s / CFM 755 / 1600 741 / 1570
dBA 52 54
mm/in 756 / 29.8 756 / 29.8
mm/in 855 / 33.7 855 / 33.7
mm/in 328 / 12.9 328 / 12.9
mm/in 810 / 31.9 810 / 31.9
mm/in 990 / 39.0 990 / 39.0
mm/in 415 / 16.3 415 / 16.3
kg/lb 62 / 136.7 65 / 143.3
FLARE VALVE FLARE VALVE
LIQUID mm/in 9.52 / 3/8 9.52 / 3/8
GAS mm/in 15.88 / 5/8 15.88 / 5/8
kg/lb 1.5 / 3.30 1.75 / 3.861) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
MODELINDOOR UNIT
OUTDOOR UNIT
NOMINAL CAPACITY
NOMINAL TOTAL INPUT POWER
NOMINAL RUNNING CURRENT
POWER SOURCE
EER
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
IND
OO
R U
NIT
CONTROLAIR DISCHARGE
OPERATION
AIR FLOW
HIGH
MEDIUM
LOW
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
CONDENSATE DRAIN SIZE
WIDTH
DEPTH
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
REFRIGERANT CHARGE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
HEIGHT
38
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Engineering And Physical Data
Description : Amendment On Engineering And Physical Data
Amendment on Manual’s Page No. :
8
General Data - Cooling Only (R22)
AWM - 301
ALC - 30C
Btu/h 30000
W 8790
W 2944
A 12.60
V/Ph/Hz 220 - 240 / 1 / 50
W/W 2.99
R22
EXTERNAL ORIFICE KIT
AUTO LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
LCD REMOTE CONTROL
l/s / CFM 316 / 670
l/s / CFM 297 / 630
l/s / CFM 236 / 500
dBA 49 / 47 / 45
mm/in 360 / 14.2
mm/in 1200 / 47.2
mm/in 200 / 7.9
mm/in 420 / 16.5
mm/in 1267 / 49.9
mm/in 260 / 10.2
kg/lb 17 / 37.48
mm/in 20 / 0.8
l/s / CFM 1605 / 3400
dBA 58
mm/in 850 / 33.5
mm/in 1030 / 40.6
mm/in 400 / 15.6
mm/in 1000 / 39.4
mm/in 1200 / 47.2
mm/in 560 / 22.1
kg/lb 95 / 209.4
FLARE VALVE
LIQUID mm/in 9.52 / 3/8
GAS mm/in 15.88 / 5/8
kg/lb 1.60 / 3.531) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
MODELINDOOR UNIT
OUTDOOR UNIT
NOMINAL CAPACITY
NOMINAL TOTAL INPUT POWER
NOMINAL RUNNING CURRENT
POWER SOURCE
EER
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
IND
OO
R U
NIT
CONTROLAIR DISCHARGE
OPERATION
AIR FLOW
HIGH
MEDIUM
LOW
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
CONDENSATE DRAIN SIZE
WIDTH
DEPTH
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
REFRIGERANT CHARGE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
HEIGHT
NIL
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Engineering And Physical Data
Description : Amendment On Engineering And Physical Data
Amendment on Manual’s Page No. :
9
General Data - Heat pump (R22)
AWM - 09GR AWM - 10GR
ALC - 09CR ALC - 10CR
Btu/h 8800 9500
W 2580 2780
Btu/h 8600 9500
W 2520 2780
W 910 860
W 750 750
A 4.00 3.80
A 3.40 3.40
V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
W/W 2.84 3.23
W/W 3.36 3.71
R22 R22
OUTDOOR CAP. TUBE OUTDOOR CAP. TUBE
DOUBLE LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
DOUBLE LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
LCD REMOTE CONTROL LCD REMOTE CONTROL
l/s / CFM 130 / 275 142 / 300
l/s / CFM 106 / 225 118 / 250
l/s / CFM 83 / 175 94 / 200
dBA 40 / 35 / 29 39 / 34 / 28
mm/in 260 / 10.2 260 / 10.2
mm/in 799 / 31.5 899 / 35.4
mm/in 198 / 7.8 198 / 7.8
mm/in 337 / 13.3 337 / 13.3
mm/in 857 / 33.7 957 / 37.7
mm/in 270 / 10.6 270 / 10.6
kg/lb 10 / 22.5 12 / 26.5
mm/in 16 / 0.6 16 / 0.6
l/s / CFM 307 / 650 396 / 840
dBA 46 46
mm/in 495 / 19.5 540 / 21.3
mm/in 600 / 23.6 700 / 27.6
mm/in 245 / 9.7 250 / 9.8
mm/in 575 / 22.6 620 / 24.4
mm/in 715 / 28.1 810 / 31.9
mm/in 330 / 13.0 330 / 13.0
kg/lb 28 / 61.7 32 / 70.5
FLARE VALVE FLARE VALVE
LIQUID mm/in 6.35 / 1/4 6.35 / 1/4
GAS mm/in 9.52 / 3/8 9.52 / 3/8
kg/lb 0.60 /1.32 0.63 / 1.391) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
WIDTH
UNIT DIMENSION
UNIT WEIGHT
PIPE CONNECTION
WIDTH
DEPTH
HEIGHT
REFRIGERANT CHARGE
IND
OO
R U
NIT
AIR FLOW
DEPTH
PACKING
DIMENSION
HEIGHT
DEPTH
OU
TD
OO
R U
NIT
TYPE
SIZE
HEIGHT
NOMINAL RUNNING CURRENT (HEATING)
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
LOW
EER
COP
POWER SOURCE
SOUND PRESSURE LEVEL (H/M/L)
WIDTHUNIT DIMENSION
AIR FLOW
INDOOR UNIT
CONTROLAIR DISCHARGE
HIGH
MODELOUTDOOR UNIT
NOMINAL RUNNING CURRENT (COOLING)
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
NOMINAL COOLING CAPACITY
MEDIUM
OPERATION
SOUND PRESSURE LEVEL
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
CONDENSATE DRAIN SIZE
39
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Engineering And Physical Data
Description : Amendment On Engineering And Physical Data
Amendment on Manual’s Page No. :
10
General Data - Heat pump (R22)
AWM - 301R AWM - 301R
ALC - 28CR ALC - 30CR
Btu/h 27000 30000
W 7913 8790
Btu/h 27000 30000
W 7913 8790
W 2708 2944
W 2273 2864
A 13.20 14.30
A 13.30 13.70
V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
W/W 2.92 2.99
W/W 3.48 3.07
R22 R22
OUTDOOR CAP. TUBE OUTDOOR CAP. TUBE
DOUBLE LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
DOUBLE LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
LCD REMOTE CONTROL LCD REMOTE CONTROL
l/s / CFM 316 / 670 316 / 670
l/s / CFM 297 / 630 297 / 630
l/s / CFM 236 / 500 236 / 500
dBA 49 / 47 / 45 49 / 47 / 45
mm/in 360 / 14.2 360 / 14.2
mm/in 1200 / 47.2 1200 / 47.2
mm/in 200 / 7.9 200 / 7.9
mm/in 420 / 16.5 420 / 16.5
mm/in 1267 / 49.9 1267 / 49.9
mm/in 260 / 10.2 260 / 10.2
kg/lb 17 / 37.48 17 / 37.48
mm/in 20 / 0.8 20 / 0.8
l/s / CFM 741 / 1570 1605 / 3400
dBA 54 58
mm/in 756 / 29.8 850 / 33.5
mm/in 855 / 33.7 1030 / 40.6
mm/in 328 / 12.9 400 / 15.8
mm/in 810 / 31.9 1000 / 39.4
mm/in 990 / 39.0 1200 / 47.2
mm/in 415 / 16.3 560 / 22.1
kg/lb 68 / 150 95 / 209
FLARE VALVE FLARE VALVE
LIQUID mm/in 9.52 / 3/8 9.52 / 3/8
GAS mm/in 15.88 / 5/8 15.88 / 5/8
kg/lb 1.83 / 4.03 2.15 / 4.741) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
MODELINDOOR UNIT
OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
NOMINAL RUNNING CURRENT (COOLING)
NOMINAL RUNNING CURRENT (HEATING)
POWER SOURCE
EER
COP
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
IND
OO
R U
NIT
CONTROLAIR DISCHARGE
OPERATION
AIR FLOW
HIGH
MEDIUM
LOW
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
CONDENSATE DRAIN SIZE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
REFRIGERANT CHARGE
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
42
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Engineering And Physical Data
Description : Amendment On Engineering And Physical Data
Amendment on Manual’s Page No. :
11
General Data - Cooling Only (R22)
A5WM - 07G A5WM - 09G
A5LC - 07C A5LC - 10C
Btu/h 7500 9000
W 2200 2640
W 620 860
A 2.90 3.90
V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
W/W 3.55 3.07
R410A R410A
OUTDOOR CAP. TUBE OUTDOOR CAP. TUBE
DOUBLE LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
DOUBLE LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
LCD REMOTE CONTROL LCD REMOTE CONTROL
l/s / CFM 130 / 275 130 / 275
l/s / CFM 106 / 225 106 / 225
l/s / CFM 83 / 175 83 / 175
dBA 40 / 35 / 29 40 / 35 / 29
mm/in 260 / 10.2 260 / 10.2
mm/in 799 / 31.5 799 / 31.5
mm/in 198 / 7.8 198 / 7.8
mm/in 337 / 13.3 337 / 13.3
mm/in 857 / 33.7 857 / 33.7
mm/in 270 / 10.6 270 / 10.6
kg/lb 10 / 22.0 10 / 22.0
mm/in 16 / 0.6 16 / 0.6
l/s / CFM 307 / 650 396 / 840
dBA 44 46
mm/in 495 / 19.5 540 / 21.3
mm/in 600 / 23.6 700 / 27.6
mm/in 245 / 9.7 250 / 9.8
mm/in 575 / 22.6 620 / 24.4
mm/in 715 / 28.1 810 / 31.9
mm/in 330 / 13.0 330 / 13.0
kg/lb 26 / 57.3 32 / 70.5
FLARE VALVE FLARE VALVE
LIQUID mm/in 6.35 / 1/4 6.35 / 1/4
GAS mm/in 9.52 / 3/8 9.52 / 3/8
kg/lb 0.48 / 1.06 0.73 / 1.611) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
REFRIGERANT CHARGE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
CONDENSATE DRAIN SIZE
MEDIUM
LOW
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
POWER SOURCE
EER
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
IND
OO
R U
NIT
CONTROLAIR DISCHARGE
OPERATION
AIR FLOW
HIGH
MODELINDOOR UNIT
OUTDOOR UNIT
NOMINAL CAPACITY
NOMINAL TOTAL INPUT POWER
NOMINAL RUNNING CURRENT
43
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Engineering And Physical Data
Description : Amendment On Engineering And Physical Data
Amendment on Manual’s Page No. :
12
General Data - Cooling Only (R410A)
A5WM - 10G A5WM - 15G
A5LC - 10C A5LC - 15C
Btu/h 9500 12000
W 2780 3520
W 910 1230
A 3.90 5.40
V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
W/W 3.05 2.86
R410A R410A
OUTDOOR CAP. TUBE OUTDOOR CAP. TUBE
DOUBLE LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
DOUBLE LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
LCD REMOTE CONTROL LCD REMOTE CONTROL
l/s / CFM 142 / 300 163 / 345
l/s / CFM 118 / 250 135 / 285
l/s / CFM 94 / 200 104 / 220
dBA 39 / 34 / 28 42 / 36 / 29
mm/in 260 / 10.2 260 / 10.2
mm/in 899 / 35.4 899 / 35.4
mm/in 198 / 7.8 198 / 7.8
mm/in 337 / 13.3 337 / 13.3
mm/in 957 / 37.7 957 / 37.7
mm/in 270 / 10.6 270 / 10.6
kg/lb 12 / 26.5 12 / 26.5
mm/in 16 / 0.6 16 / 0.6
l/s / CFM 396 / 840 453 / 960
dBA 46 49
mm/in 540 / 21.3 540 / 21.3
mm/in 700 / 27.6 700 / 27.6
mm/in 250 / 9.8 250 / 9.8
mm/in 620 / 24.4 620 / 24.4
mm/in 810 / 31.9 810 / 31.9
mm/in 330 / 13.0 330 / 13.0
kg/lb 33 / 70.5 32 / 70.5
FLARE VALVE FLARE VALVE
LIQUID mm/in 6.35 / 1/4 6.35 / 1/4
GAS mm/in 9.52 / 3/8 12.70 / 1/2
kg/lb 0.73 / 1.61 0.83 / 1.831) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
REFRIGERANT CHARGE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
CONDENSATE DRAIN SIZE
MEDIUM
LOW
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
POWER SOURCE
EER
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
IND
OO
R U
NIT
CONTROLAIR DISCHARGE
OPERATION
AIR FLOW
HIGH
MODELINDOOR UNIT
OUTDOOR UNIT
NOMINAL CAPACITY
NOMINAL TOTAL INPUT POWER
NOMINAL RUNNING CURRENT
44
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Engineering And Physical Data
Description : Amendment On Engineering And Physical Data
Amendment on Manual’s Page No. :
13
General Data - Cooling Only (R410A)
A5WM - 311
A5LC - 28C
Btu/h 26000 / <26000>
W 7620 / <7620>
W 2560 / <2631>
A 12.2 / <4.6>
V/Ph/Hz 220-240/ 1/ 50 / <380-415/ 3/ 50>
W/W 2.98 / <2.90>
R410A
OUTDOOR CAP. TUBE
AUTO LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
LCD REMOTE CONTROL
l/s / CFM 316 / 670
l/s / CFM 297 / 630
l/s / CFM 236 / 500
dBA 49 / 47 / 45
mm/in 360 / 14.2
mm/in 1200 / 47.2
mm/in 200 / 7.9
mm/in 420 / 16.5
mm/in 1267 / 49.9
mm/in 260 / 10.2
kg/lb 17 / 37.5
mm/in 20 / 0.8
l/s / CFM 632 / 1340
dBA 54
mm/in 756 / 29.8
mm/in 855 / 33.7
mm/in 328 / 12.9
mm/in 810 / 31.9
mm/in 990 / 39.0
mm/in 415 / 16.3
kg/lb 68 / 149.9
FLARE VALVE
LIQUID mm/in 9.52 / 3/8
GAS mm/in 15.88 / 5/8
kg/lb 1.80 / 3.971) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
MODELINDOOR UNIT
OUTDOOR UNIT
NOMINAL CAPACITY-1Ø/ <3Ø>
NOMINAL TOTAL INPUT POWER-1Ø/ <3Ø>
NOMINAL RUNNING CURRENT-1Ø/ <3Ø>
POWER SOURCE-1Ø/ <3Ø>
EER-1Ø/ <3Ø>
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
IND
OO
R U
NIT
CONTROLAIR DISCHARGE
OPERATION
AIR FLOW
HIGH
MEDIUM
LOW
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
CONDENSATE DRAIN SIZE
WIDTH
DEPTH
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
REFRIGERANT CHARGE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
HEIGHT
46
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Engineering And Physical Data
Description : Amendment On Engineering And Physical Data
Amendment on Manual’s Page No. :
14
General Data - Heat pump (R410A)
A5WM - 07GR A5WM - 09GR
A5LC - 07CR A5LC - 10CR
Btu/h 7500 9000
W 2200 2640
Btu/h 7500 9000
W 2200 2640
W 680 860
W 550 745
A 3.10 3.90
A 2.60 3.40
V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
W/W 3.24 3.07
W/W 4.00 3.54
R410A R410A
OUTDOOR CAP. TUBE OUTDOOR CAP. TUBE
DOUBLE LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
DOUBLE LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
LCD REMOTE CONTROL LCD REMOTE CONTROL
l/s / CFM 130 / 275 130 / 275
l/s / CFM 106 / 225 106 / 225
l/s / CFM 83 / 175 83 / 175
dBA 40 / 35 / 29 40 / 35 / 29
mm/in 260 / 10.2 260 / 10.2
mm/in 799 / 31.5 799 / 31.5
mm/in 198 / 7.8 198 / 7.8
mm/in 337 / 13.3 337 / 13.3
mm/in 857 / 33.7 857 / 33.7
mm/in 270 / 10.6 270 / 10.6
kg/lb 10 / 22.0 10 / 22.0
mm/in 16 / 0.6 16 / 0.6
l/s / CFM 307 / 650 396 / 840
dBA 44 46
mm/in 495 / 19.5 540 / 21.3
mm/in 600 / 23.6 700 / 27.6
mm/in 245 / 9.7 250 / 9.8
mm/in 575 / 22.6 620 / 24.4
mm/in 715 / 28.1 810 / 31.9
mm/in 330 / 13.0 330 / 13.0
kg/lb 26 / 57.3 32 / 70.5
FLARE VALVE FLARE VALVE
LIQUID mm/in 6.35 / 1/4 6.35 / 1/4
GAS mm/in 9.52 / 3/8 9.52 / 3/8
kg/lb 0.50 /1.10 0.73 / 1.611) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
MODELINDOOR UNIT
OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
NOMINAL RUNNING CURRENT (COOLING)
NOMINAL RUNNING CURRENT (HEATING)
POWER SOURCE
EER
COP
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
IND
OO
R U
NIT
CONTROLAIR DISCHARGE
OPERATION
AIR FLOW
HIGH
MEDIUM
LOW
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
CONDENSATE DRAIN SIZE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
REFRIGERANT CHARGE
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
47
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Engineering And Physical Data
Description : Amendment On Engineering And Physical Data
Amendment on Manual’s Page No. :
15
General Data - Heat pump (R410A)
A5WM - 301R
A5LC - 28CR
Btu/h 26000 / <26000>
W 7620 / <7620>
Btu/h 26000 / <26000>
W 7620 / <7620>
W 2560 / <2631>
W 2442 / <2294>
A 12.2 / <4.6>
A 11.6 / <4.2>
V/Ph/Hz 220-240/ 1/ 50 / <380-415/ 3/ 50>
W/W 2.98 / <2.90>
W/W 3.12 / <3.32>
R410A
OUTDOOR CAP. TUBE
AUTO LOUVER (UP & DOWN) &
GRILLE (LEFT & RIGHT)
LCD REMOTE CONTROL
l/s / CFM 316 / 670
l/s / CFM 297 / 630
l/s / CFM 236 / 500
dBA 49 / 47 / 45
mm/in 360 / 14.2
mm/in 1200 / 47.2
mm/in 200 / 7.9
mm/in 420 / 16.5
mm/in 1267 / 49.9
mm/in 260 / 10.2
kg/lb 17 / 37.5
mm/in 20 / 0.8
l/s / CFM 632 / 1340
dBA 54
mm/in 756 / 29.8
mm/in 855 / 33.7
mm/in 328 / 12.9
mm/in 810 / 31.9
mm/in 990 / 39.0
mm/in 415 / 16.3
kg/lb 68 / 149.9
FLARE VALVE
LIQUID mm/in 9.52 / 3/8
GAS mm/in 15.88 / 5/8
kg/lb 1.80 / 3.971) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
MODELINDOOR UNIT
OUTDOOR UNIT
NOMINAL COOLING CAPACITY- 1Ø / <3Ø>
NOMINAL HEATING CAPACITY- 1Ø / <3Ø>
NOMINAL TOTAL INPUT POWER (COOLING)- 1Ø / <3Ø>
NOMINAL TOTAL INPUT POWER (HEATING)- 1Ø / <3Ø>
NOMINAL RUNNING CURRENT (COOLING)- 1Ø / <3Ø>
NOMINAL RUNNING CURRENT (HEATING)- 1Ø / <3Ø>
POWER SOURCE- 1Ø / <3Ø>
EER- 1Ø / <3Ø>
COP- 1Ø / <3Ø>
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
IND
OO
R U
NIT
CONTROLAIR DISCHARGE
OPERATION
AIR FLOW
HIGH
MEDIUM
LOW
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
CONDENSATE DRAIN SIZE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
REFRIGERANT CHARGE
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
50
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Engineering And Physical Data
Description : Add In Data For AWM301/R – ALC30C/CR
Amendment on Manual’s Page No. :
16
Components Data - Cooling Only (R22)
AWM - 301
ALC - 30C
CROSS FLOW FAN
1
ACRYLO NITRILE STYRENE
DIRECT
mm/in 106 / 4.17
mm/in 950 / 37.4
INDUCTION
1
IP24
PROPELLER
1
GLASS REINFORCED ACRYL STYRENE
RESIN
DIRECT
mm/in 610 / 24
INDUCTION
1
-
SCROLL
MINERAL (Sontex 200 LT)
cm3 / fl.oz. 1240 / 43.6
SEAMLESS INNER COPPER TUBE
mm/in 9.52 / 0.375
mm/in 0.35 / 0.013
ALUMINIUM (HYDROPHILIC SLIT FIN
TYPE)mm/in 0.11 / 0.0043
m2/ft
2 0.291 / 3.130
2
16
SEAMLESS COPPER TUBE
mm/in 9.52/ 0.375
mm/in 0.35 / 0.014
ALUMINIUM (SLIT FIN TYPE)
mm/in 0.12 / 0.005
m2/ft
2 0.87 / 9.33
1
16
SARANET + IONIZER
pc 3 X 3
LENGTH mm/in 330 / 13.0
WIDTH mm/in 317 / 12.4
THICKNESS mm/in 1.8 / 0.07
NO
MATERIAL ABS
COLOUR LIGHT GREY
MATERIAL GALVANISED MILD STEEL
COLOUR LIGHT GREY
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
MODELINDOOR UNIT
OUTDOOR UNIT
INDOOR FAN
TYPE
QUANTITY
MATERIAL
DRIVE
DIAMETER
LENGTH
INDOOR FAN
MOTOR
TYPE
QUANTITY
INDEX OF PROTECTION (IP)
OUTDOOR FAN
TYPE
QUANTITY
MATERIAL
DRIVE
DIAMETER
ROW
OUTDOOR FAN
MOTOR
TYPE
QUANTITY
INDEX OF PROTECTION (IP)
COMPRESSOR
TYPE
OIL TYPE
OIL AMOUNT
FACE AREA
INDOOR COIL
TUBE
MATERIAL
DIAMETER
THICKNESS
FIN
MATERIAL
THICKNESS
FACE AREA
NEGATIVE IONIZER
FIN PER INCH
OUTDOOR COIL
TUBE
MATERIAL
DIAMETER
THICKNESS
FIN
MATERIAL
THICKNESS
CASING
INDOOR UNIT
OUTDOOR UNIT
ROW
FIN PER INCH
AIR QUALITYFILTER
TYPE
QUANTITY
SIZE
NIL
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Engineering And Physical Data
Description : Add In Data For AWM301/R – ALC30C/CR
Amendment on Manual’s Page No. :
17
Components Data - Heatpump (R22)
AWM - 301R AWM - 301R
ALC - 28CR ALC - 30CR
ANTI FUNGUS CROSS FLOW FAN ANTI FUNGUS CROSS FLOW FAN
1 1
ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE
DIRECT DIRECT
mm/in 106 / 4.17 106 / 4.17
mm/in 950 / 37.4 950 / 37.4
INDUCTION INDUCTION
1 1
IP24 IP24
PROPELLER PROPELLER
1 1
GLASS REINFORCED ACRYL STYRENE
RESIN
GLASS REINFORCED ACRYL STYRENE
RESIN
DIRECT DIRECT
mm/in 457.2/18 610.0/24
INDUCTION INDUCTION
1 1
IP54 -
ROTARY HERMETIC SCROLL
ATMOS M60 or SUNISO 4GDID MINERAL (Sontex 200 LT)
cm3 / fl.oz. 1130 / 39.8 1240 / 43.6
SEAMLESS INNER GROOVE COPPER SEAMLESS COPPER TUBE
mm/in 9.52 / 0.375 9.52 / 0.375
mm/in 0.35 / 0.013 0.35 / 0.013
ALUMINIUM (HYDROPHILIC SLIT FIN TYPE) ALUMINIUM (HYDROPHILIC SLIT FIN TYPE)
mm/in 0.11 / 0.0043 0.11 / 0.004
m2/ft
2 0.291 / 3.130 0.291 / 3.130
2 2
16 16
SEAMLESS INNER GROOVE COPPER SEAMLESS COPPER TUBE
mm/in 9.52 / 3/8 9.52 / 3/8
mm/in 0.33 / 0.013 0.33 / 0.013
ALUMINIUM (SLIT FIN) ALUMINIUM (SLIT FIN)
mm/in 0.11 / 0.004 0.12/ 0.005
m2/ft
2 0.61 / 6.52 0.87 / 9.33
2 2
18 16
SARANET + IONIZER SARANET + IONIZER
pc 3 X 3 3 X 3
LENGTH mm/in 330 / 13.0 330 / 13.0
WIDTH mm/in 317 / 12.4 317 / 12.4
THICKNESS mm/in 1.8 / 0.07 1.8 / 0.07
NO NO
MATERIAL ABS ABS
COLOUR LIGHT GREY LIGHT GREY
MATERIAL GALVANISED MILD STEEL GALVANISED MILD STEEL
COLOUR LIGHT GREY LIGHT GREY
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
MATERIAL
TYPE
QUANTITY
MATERIAL
ROW
FIN PER INCH
DIAMETER
THICKNESS
THICKNESS
FACE AREA
COMPRESSOR
TYPE
OIL TYPE
INDEX OF PROTECTION (IP)
OUTDOOR FAN
MOTOR
OIL AMOUNT
QUANTITY
DIAMETER
LENGTH
OUTDOOR FAN MATERIAL
DRIVE
TYPE
TYPE
QUANTITY
DIAMETER
INDOOR UNIT
OUTDOOR UNITMODEL
TYPE
INDOOR FAN
INDOOR FAN
MOTOR
QUANTITY
MATERIAL
DRIVE
INDEX OF PROTECTION (IP)
INDOOR COIL
OUTDOOR COIL
FIN
FIN
TUBE
TUBE
CASING
FILTER
SIZE
QUANTITY
TYPE
INDOOR UNIT
OUTDOOR UNIT
NEGATIVE IONIZER
AIR QUALITY
MATERIAL
MATERIAL
ROW
FIN PER INCH
DIAMETER
THICKNESS
THICKNESS
FACE AREA
58
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Performance Data
Description : Add In Performance Data For AWM301/R – ALC30C/CR
Amendment on Manual’s Page No. : NIL
18
Performance Data
Cooling Only (R22)
Model : AWM301 – ALC30C
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Performance Data
Description : Add In Performance Data For AWM301/R – ALC30C/CR
Amendment on Manual’s Page No. : NIL
19
Heat Pump (R22) Model : AWM301R – ALC30CR
Cooling Mode
Model : AWM301R – ALC30CR
Heating Mode
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Outline Dimension
Description : Add In Outline Dimension For AWM301/R – ALC30C/CR
Amendment on Manual’s Page No. : NIL
20
Outline and Dimension
Indoor Unit
Model : AWM 301/301R
Outdoor Unit
Model : ALC 30C/CR
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Electrical Data
Description : Add In Electrical Data For AWM301/R – ALC30C/CR
Amendment on Manual’s Page No. :
21
Electrical Data
Electrical Data – Cooling Only (R22) AWM - 301
ALC - 30C
CLASS B
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50
RATED INPUT POWER W 71
RATED RUNNING CURRENT A 0.30
MOTOR OUTPUT W 40
4
CLASS B
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50
RATED INPUT POWER W 220
RATED RUNNING CURRENT A 1.02
MOTOR OUTPUT W 145
8
-
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50
CAPACITOR µµµµF 50.0
RATED INPUT POWER W 2377
RATED RUNNING CURRENT A 11.50
LOCKED ROTOR AMP. A 82
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
MODELINDOOR UNIT
OUTDOOR UNIT
INDOOR MOTOR
INSULATION GRADE
POLES
OUTDOOR MOTOR
INSULATION GRADE
POLES
COMPRESSOR
INSULATION GRADE
Electrical Data – Heat Pump (R22) AWM - 301R AWM - 301R
ALC - 28CR ALC - 30CR
CLASS B CLASS B
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
RATED INPUT POWER W 71 71
RATED RUNNING CURRENT A 0.30 0.30
MOTOR OUTPUT W 75 75
4 4
CLASS B CLASS B
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
RATED INPUT POWER W 142 220
RATED RUNNING CURRENT A 0.62 1.02
MOTOR OUTPUT W 75 145
6 8
CLASS E -
POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50
CAPACITOR µµµµF 50.0 50.0
RATED INPUT POWER (COOLING) W 2570 2377
RATED INPUT POWER (HEATING) W 2610 2584
RATED RUNNING CURRENT (COOLING) A 12.30 11.50
RATED RUNNING CURRENT (HEATING) A 12.40 12.30
LOCKED ROTOR AMP. A 66 82
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
MODELINDOOR UNIT
OUTDOOR UNIT
INDOOR MOTOR
INSULATION GRADE
POLES
COMPRESSOR
INSULATION GRADE
OUTDOOR MOTOR
INSULATION GRADE
POLES
103
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Wiring Diagram
Description : Add In Wiring Diagram For AWM301/R – ALC30C/CR
Amendment on Manual’s Page No. : NIL
22
Wiring Diagram
Cooling Only Model
Indoor Unit
Model : AWM301
Outdoor Unit
Model : ALC30C
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Wiring Diagram
Description : Add In Wiring Diagram For AWM301/R – ALC30C/CR
Amendment on Manual’s Page No. : NIL
23
Heat Pump Model
Indoor Unit
Model : AWM301R
Outdoor Unit
Model : ALC30CR
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Exploded View And Parts List
Description : Add In Exploded View and Parts List For AWM301/R – ALC30C/CR
Amendment on Manual’s Page No. :
24
Exploded View and Parts List
Outdoor Unit
Model : ALC30C
1 Assy. Base Pan R50014053238 13 Fan Motor R03039004046
2 Assy. 3 Way VLV 3/8" R50059030464 14 Fan Blade R03013028160
3 Assy. 3 Way VLV 5/8" R50059030532 15 Assy. Front Panel R50014053236
4 Assy. Panel, Partition R50014053277 16 Valve Plate R01013034235
5 Assy. Compressor R50049013221 Part Not In Diagram
6 Service Panel R01010029898 Capacitor, Compressor R04029026779
7 Accumulator R02119025988 Capacitor, Fan Motor R04029026761
8 Panel, Back Right R01014053233Y Pressure Switch R04109031314
9 Top Panel R01011029900 Contactor R04039018866
10 Assy. Coil R50024041851 Fan Guard R01023030109
11 Fan Motor Bracket R01014053232 Assy. Terminal Board Main R50044067920
12 Panel Side Left R01013029899
No Description Part Number No Description Part Number
NIL
Amendment Sheet
Manual : Wall Mounted Split System Code : AWM-G-2009-0002
Subject : Exploded View and Parts List
Description : Add In Exploded View and Parts List For AWM301/R – ALC30C/CR
Amendment on Manual’s Page No. :
25
Outdoor Unit
Model : ALC30CR
1 Assy. Base Pan R50014053238 13 Fan Motor R03039004046
2 Assy. 3 Way VLV 3/8" R50059030464 14 Fan Blade R03013028160
3 Assy. 3 Way VLV 5/8" R50059030532 15 Assy. Front Panel R50014053236
4 Assy. Panel, Partition R50014053277 16 Valve Plate R01013034235
5 Assy. Compressor R50049013221 Part Not In Diagram
6 Service Panel R01010029898 Capacitor, Compressor R04029026779
7 Accumulator R02114013198 Capacitor, Fan Motor R04029026761
8 Panel, Back Right R01014053233Y Pressure Switch R04109031314
9 Top Panel R01011029900 Contactor R04039018866
10 Assy. Coil R50024035282 Fan Guard R01023030109
11 Fan Motor Bracket R01014053232 Assy. Terminal Board Main R50044067926
12 Panel Side Left R01013029899 Valve, 4-Way R05029001991
No Description Part Number No Description Part Number
NIL
26
Revision Table
Code Subject Amendment on
Manual’s Page No. Date
AWM-G-2009-0001 New Low Ambient Range Launching NIL 29.4.2009
AWM-G-2009-0002 Amendment For WM Split System Manual 5,6,12,37-39,42-
44,46,47,50,58,103 02.7.2009