© 2010 American Standard Heating & Air ConditioningNOTICE: The manufacturer has a policy of continuous product and product data improvement and
reserves the right to change design and specifications without notice.
SPECIFICATIONSTAG: _________________________________
SINGLE PACKAGED GAS HEATINGELECTRIC COOLING
4YCC3036A4064/75/96B
PRODUCT SPECIFICATIONS
4YCC3036A-SPEC-4
MODELRATED Volts/PH/HzPerformance Cooling BTUH�Indoor Airflow (CFM)Power Input (KW)EER/SEER (BTU/Watt-Hr.)Sound Power Rating [db(A)]7Performance Heating�Input BTUH (Natural Gas)�AFUETemp. Rise — Min/Max (°F)Orifice Qty / Drill Size (Natural Gas)POWER CONN.—V/PH/HZMin. Brch. Cir. AmpacityFuse Size — Max. (amps)Fuse Size — Recmd. (amps)COMPRESSORVolts/Ph/HzR.L. Amps — L.R. AmpsOUTDOOR COIL — TYPERows/F.P.I.Face Area (sq.ft.)Tube Size (in.)INDOOR COIL — TYPERows/F.P.I.Face Area (sq.ft.)Tube Size (in.)Refrigerant ControlDrain Conn. Size (in.)OUTDOOR FAN — TYPEDia. (in.)Drive/No. SpeedsCFM @ 0.0 in. w.g. 8Motor — HP/R.P.M.Volts/Ph/HzF.L. Amps/L.R. AmpsINDOOR FAN — TYPEDia x Width (in.)Drive/No. SpeedsCFM @ 0.0 in. w.g.�Motor — HP/R.P.M.Volts/Ph/HzF.L. Amps/L.R. AmpsCOMBUSTION FAN — TYPEDrive/No. SpeedsMotor — HP/R.P.M.Volts/Ph/HzFLAFILTER / FURNISHEDType RecommendedRecmd. Face Area (sq. ft.)�REFRIGERANTCharge (lbs.)�GAS PIPE SIZE (in.)DIMENSIONSCrated (in.)WEIGHTShipping (lbs.) / Net (lbs.)
11111Rated in accordance with AHRI Standard210/240. AHRI standard rating conditionsare: 80 D.B. 67 W.B. entering air to indoorcoil. 95 D.B. entering air to outdoor coil.
22222 All models are certified to UL 1995. Ratingsshown are for elevations up to 2000 ft. Forhigher elevations reduce ratings at a rateof 4% per 1000 ft. elevation.
33333 Convertible to LPG.44444 This value is approximate. For more precise
value, see Unit Nameplate.55555 Based on U.S. Government Standard Tests.66666 Filters must be installed in return air stream.
Square footages listed are based on 300f.p.m. face velocity. If permanent filters areused size per manufacturer's recommenda-tion with a clean resistance of 0.05" W.C.0.05" W.C.
77777 Sound Power values are not adjusted forAHRI 270-95 tonal corrections.
88888 Standard Air — Dry Coil — Outdoor.
4YCC3036A4064B460/3/60
3500012003.284
11.0 / 13.075
6400080.0
25 / 552 / #37
460/3/609.51515
SCROLL460/3/605.8 / 38
SPINE-FIN2 / 2413.32
3/8PLATE FIN
4 / 153.543/8
EXPANSION VALVE3/4 FEMALE NPT
PROPELLER23
DIRECT / 13240
1/5 / 830460/1/600.6 / 1.3
CENTRIFUGAL10 X 10
DIRECT / 2SEE FAN PERF TABLE
1/2 / 1075460/1/601.7 / 3.12
CENTRIFUGALDIRECT / 11/35 / 3480
460/1/600.25NO
THROWAWAY4
R410A8.001/2
H X W X L45.86 / 44.5 / 52.03
488 / 392
4YCC3036A4075B460/3/60
3500012003.284
11.0 / 13.075
7500080.0
30 / 602 / #33
460/3/609.51515
SCROLL460/3/605.8 / 38
SPINE-FIN2 / 2413.32
3/8PLATE FIN
4 / 153.543/8
EXPANSION VALVE3/4 FEMALE NPT
PROPELLER23
DIRECT / 13240
1/5 / 830460/1/600.6 / 1.3
CENTRIFUGAL10 X 10
DIRECT / 2SEE FAN PERF TABLE
1/2 / 1075460/1/601.7 / 3.12
CENTRIFUGALDIRECT / 11/35 / 3480
460/1/600.25NO
THROWAWAY4
R410A8.001/2
H X W X L45.86 / 44.5 / 52.03
488 / 392
4YCC3036A4096B460/3/60
3500012003.284
11.0 / 13.075
9600080.0
40 / 703 / #37
460/3/609.51515
SCROLL460/3/605.8 / 38
SPINE-FIN2 / 2413.32
3/8PLATE FIN
4 / 153.543/8
EXPANSION VALVE3/4 FEMALE NPT
PROPELLER23
DIRECT / 13240
1/5 / 830460/1/600.6 / 1.3
CENTRIFUGAL10 X 10
DIRECT / 2SEE FAN PERF TABLE
1/2 / 1075460/1/601.7 / 3.12
CENTRIFUGALDIRECT / 11/35 / 3480
460/1/600.25NO
THROWAWAY4
R410A8.001/2
H X W X L45.86 / 44.5 / 52.03
493 / 397
2
Unit Clearance and Weight Information
3
4
5
Indoor Fan Performance 4YC*3036A
Down Airflow
Horizontal Airflow
Unit Performance Data
4YC*3036A-HOR EXTERNAL STATIC PRESSURE (IN. WG)
MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
LOWWATTS 470 448 434 420 402 378 351 - - - -
CFM 1332 1292 1240 1177 1100 1007 896 - - - -
HIGHWATTS - 670 651 634 616 595 569 536 498 - -
CFM - 1542 1472 1426 1364 1267 1135 989 869 - -
4YC*3036A-DOWN EXTERNAL STATIC PRESSURE (IN. WG)
MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
LOWWATTS 460 445 431 416 400 381 358 - - - -
CFM 1267 1257 1198 1124 1050 966 843 - - - -
HIGHWATTS - 713 694 676 657 636 612 588 - - -
CFM - 1584 1502 1420 1327 1221 1100 970 - - -
6
46 3/8
17 7/8
3
3 5/8
19 1/2
2 3/16
19 1/2
14
1 1/2
38 7/8
15
35 7/843 3/8
BAYCURB050A Full Perimeter Roof Mounting Curb for *****018-036
The drawings on this page areprepared by the manufacturer in orderto provide detail regarding job layoutonly. These drawings are not intendedto be used as a basis to construct,build or modify the items depicted inthe drawings. The manufacturer is notresponsible for the unauthorized useof these drawings and expresslydisclaims any liability for damagesresulting from such unauthorized use.
7
The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. Thesedrawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manu-facturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damagesresulting from such unauthorized use.
BAYFLTR101, 201B, 1" - 2" Filter Rack(Mounts in Filter/Coil Section)
BAYACCDOR1A & BAYACCDOR2A Hinged Filter Access DoorReplaces Filter/Coil Access Panel
Filter
8
BAYECON101,102A Down Discharge Economizer and Rain Hood(Mounts Over Horizontal Return Air Opening)
A
B
C D
E
BAYECON200,201A Horizontal Economizer and Rain Hood
ReturnDuctRoofcurb
Reliefdamper
Misteliminator
Economizerrain hood
HVAC Unit
Outside airdampers
Returnairdampers
Required filterkit, orderseparately
A
Economizer Unit Application Models A
BAYECON101A4TC*,WC*,YC*,DC*
*018-03620.125"
BAYECON102A4TC*,WC*,YC*, DC*
*042-06024.375"
Economizer A B C D E F
BAYECON200AA 22" 20" 16 7/8" 15 11/16 11 11/16 15
BAYECON201AA 26" 22 21/32" 19" 17 11/16 14 11/16 21-3/8
Economizer
Gaskets (2)
Rain HoodDuct
The drawings on this pageare prepared by themanufacturer in order toprovide detail regardingjob layout only. Thesedrawings are not intendedto be used as a basis toconstruct, build or modifythe items depicted in thedrawings. The manufac-turer is not responsible forthe unauthorized use ofthese drawings andexpressly disclaims anyliability for damagesresulting from suchunauthorized use.
Mixed Air Sensor
9
A
B
CD
FULLYOPEN
2/31/3
FULLYCLOSED
BAYDMPR101,102A, 25% Motorized Outside Air Damper(Mounts Over Horizontal Return AIr Opening)
BAYOSAH001,002A, 25% Outside Air Damper(Replaces Filter/Coil Access Panel)
The drawings on this page are pre-pared by the manufacturer in order toprovide detail regarding job layout only.These drawings are not intended to beused as a basis to construct, build ormodify the items depicted in thedrawings. The manufacturer is notresponsible for the unauthorized use ofthese drawings and expressly dis-claims any liability for damagesresulting from such unauthorized use.
Manual FreshAir Model
Unit ApplicationModels
A B C D
BAYOSAH001
4YC,WC3018-0364TC*3018-036
4W/T/Y/DCY4024-0364W/Y/DCZ6036
22 7/16" 20 11/16" 12 3/8" 9 3/16"
BAYOSAH002
4YC,WC3042-0604TC*3042-060
4W/T/Y/DCY4042-0604W/Y/DCZ6048-060
25 3/16" 20 11/16" 12 3/8" 9 3/16"
D
C B
A
E
Unit ApplicationModels
A B C D E
BAYDMPR101A
4YC,WC3018-0364TC3018-036
4W/T/Y/DCY4024-0364W/Y/DCZ6036
15 13/16" 11 13/16" 10 1/4" 11 1/2" 12 1/4"
BAYDMPR102A
4YC,WC3042-0604TC3042-060
4W/T/Y/DCY4042-0604W/Y/DCZ6048-060
18 3/16" 15 1/8" 10 1/4" 11 1/2" 12 1/4"
American StandardHeating & Air Conditioning6200 Troup HighwayTyler, TX 75707
MechanicalSpecification Options
GeneralAll units shall be factory assembled, piped,internally wired and fully charged withrefrigerant. All units shall be designed tooperate at outdoor ambient temperaturesas high as 115°F. Cooling capacities shallbe rated in accordance with A.H.R.I.standards. The heating/cooling unitdesign is certified to ANSI 221.47/CSA 2.3,specifically for outdoor applications usingnatural gas or propane. All units shall bedesigned for outdoor rooftop or groundlevel installation. Unit casing isconstructed of heavy gauge, galvanizedsteel and painted with a weather-resistantpowder paint.
Shipped for horizontal application,convertible to downflow.
CasingsAll panels shall be heavy gauge steel,gasketed and insulated. Foil-faced fiberinsulation shall be in the heat exchangersection. Foil-faced insulation shall be inthe evaporator section. Base pan shall beheavy gauge steel. WEATHERGUARD™exterior corrosion resistant screws shall beused for added resistance to rust andcorrosion.
ControlsRefrigeration cycle controls shall includecondenser fan, evaporator fan andcompressor contactors. Compressorsshall be equipped with a combinationinternal winding thermostat/currentoverload. Internal high pressure reliefshall also be provided.
Refrigeration SystemCompressors —The Duration™ compressor featuresinternal over temperature and pressureprotector, total dipped hermetic motor.Other features include: centrifugal oilpump, low vibration and noise.
Evaporator Coil — Internally enhanced3/8-inch OD seamless copper tubingmechanically bonded to aluminum fins,factory pressure and leak tested at 250 to300 psig. All units have TXV to controlrefrigeration flow.
Condenser Coil —The Spine Fin™condenser coil shall becontinuously wrapped, corrosion resistantall aluminum with minimum brazed joints.This coil is 3/8 inch O.D. seamlessaluminum tubing glued to a continuousaluminum fin. Coils are lab tested towithstand 2,000 pounds of pressure persquare inch. The outdoor coil provideslow airflow resistance and efficient heattransfer. The coil is protected on all foursides by louvered panels.
Indoor Air Fan — Direct-drive, forward-curved, centrifugal wheel in a CompositeVortica® Blower housing. Motor shallhave thermal overload protection.Permanently lubricated motor bearings.Motor/blower assembly isolated from unitwith rubber mounts.
Condenser Fan — Direct-drive, drawthru propeller type. Weather-proofedpermanent split capacitor fan motor shallhave built-in thermal overload andpermanently lubricated motor bearings.
Low Ambient — Standard refrigerantsystem operation down to 55°F. Lowambient accessory required for operationto 0°F ambient condition.
Heating SystemGas-Fired Heating Section — Modelsshall provide completely assembled,wired and piped gas fired heatingsystems within unit. Design certified byUL, specifically for outdoor application.Threaded gas connection on the unit.
Electronic Ignition System — Mainburner is lit each time thermostat calls forheat. Flame sensor proves flame andkeeps the main burners on. Should a lossof flame occur, the main valve closes andthe spark recurs within 0.8 second. Whenthermostat is satisfied, main burner isextinguished.
Forced Combustion Blower — Insuresflame stability under varying windconditions. Gives higher combustionefficiency and location flexibility.
Heat Exchanger — stainless steel tubes.Free floating design.
Burners — stainless steel. Multi-portinshot.
Downflow Accessories(U.S. Domestic Models)Roof Curb — The roof curb shall bedesigned to mate with the unit andprovide support and complete weather-tight installation when properly installed.Curb shall ship knocked down for fieldassembly, and include wood nailer strips.
EconomizerModulating Economizer — Thisaccessory shall be field installed and becomposed of the following items: 0-100%fresh air damper, damper drive motorfixed dry bulb enthalpy control, and lowvoltage polarized plug for electricalconnections. Solid state enthalpy ordifferential enthalpy control is optional.Economizer operations shall becontrolled by the preset position of theenthalpy control. A barometic reliefdamper shall be standard with theeconomizer and provide a pressureoperated damper that shall be gravityclosing and prohibit entrance of outsideair on equipment “off” cycle.
Manual Fresh Air HoodManual outside air provides a fixedoutside air quantity from 0 to 25 percent.Includes hood and birdscreen.
Low Ambient ControlControl allows cycling of compressorunder low ambient cooling conditions.Required for cooling operation to 0°F.
Propane GasConversion Kit — For conversion fromnatural gas to LP gas.