American Safe Room, Inc.
2009 Product Catalogof
CBRNE Protection Equipment
everything you needto build a military grade
protected space in yourunderground shelter
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
2
Table of Contents
Contact Information --------------------------------------------------------------------- 3
Product Availability and Shipping Information ----------------------------------------- 3
Fundamentals of a Protected Space ---------------------------------------------------- 4
Critical Components of an Underground Shelter --------------------------------------- 5
Safe Cell System Components ---------------------------------------------------------- 6
Air Filtration Systems----------------------------------------------------------------- 7, 8
Safe Cell — 120 to 240 volt AC with battery backup--------------------------- 7Safe Cell — 120 or 240 volt AC ------------------------------------------------- 8Safe Cell — 12 or 24 volt DC ---------------------------------------------------- 8Safe Cell — 120 or 240 volt AC and 12 volt DC - external blower ------------ 8Complete Blast Protected NBC Filter System ----------------------------------- 8
Air Filtration Accessories ---------------------------------------------------- 9 through 20
Replacement Filters -------------------------------------------------------------- 9Emergency Backup Hand Pump ------------------------------------------------ 10Overpressure Valve --------------------------------------------------------- 11, 12Automatic Ventilation System -------------------------------------------------- 13External Blowers ---------------------------------------------------------------- 14
Installation Kits ------------------------------------------------------------ 15 through 17
Through the Wall Kit ------------------------------------------------------------ 15Automotive Bulkhead Vent Kit ------------------------------------------------- 16Steel Ventilation Pipes ---------------------------------------------------------- 17
Blast Protection Equipment ----------------------------------------------- 18 through 20
Blast Valve ---------------------------------------------------------------------- 18Blast Door ----------------------------------------------------------------------- 19Blast Hatch ---------------------------------------------------------------------- 20
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
3
Items in this catalog are either stock items orspecial order items.
Stock items usually ship within 2 business days.
Special order items require a 50% deposit attime of ordering and the balance due beforeshipping. A picture of the item, ready forshipment, will be provided before the balance isdue and the item will ship the same day or thenext business day after the payment is made.
All items are required to be prepaid prior toshipping.
American Safe Room usually ships by UPS. Othershippers used are Federal Express, DHL, and thePost Service - available upon request.
Blast doors, blast valves, and ventilation pipesship by USF Reddaway.
Shipping charges are added to every order. Thequotation from the shipper will be providedattached to the invoice. American Safe Roomnever charges any handling fees.
Export orders requiring an export licence arecharged an additional $175 and usually takeabout six weeks to get each license.
Availability and Shipping
Address American Safe Room, Inc.PO Box 255Oakland, OR 97462
Tel. 541-459-1806FAX 503-212-6695
E-mail [email protected]@mailasr.com
Websites www.AmericanBombShelter.comwww.AmericanSafeRoom.comwww.AmericanIsolationRoom.com
DUNS 135227549GSA GS 07F-5638PCAGE 3G8X7
American Safe Room is the manufacturer of allthe items in this catalog.
The Safe Cell has been given a commodityjurisdiction by the US State Department anddeemed a Class XIV Munition.
American Safe Room is registered with the USState Department as a significant defence itemmanufacturer and exporter.Registration number: M16478
Contact information
Copyright ©2009 Leonard HenriksonAll right reserved.
All text, drawings, photographs, and any othercontent shall not be reproduced by any means
without specific written consent.
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
4
Collective protection for civil defenseA nuclear, biological, and chemical (NBC) saferoom protects its occupants from inhalingharmful or deadly airborne toxins such as veryfine particles of radioactive fallout, biologicaltoxins, and chemical agents. In the past, theUnited States Government has poured extensiveresources into providingthe best information (atthe time) for theprotection of its citizensfrom NBC warfareagents. This is not thecase today.
For protection of theU.S. population we havethe governmentwebsite:www.ready.gov. Itsuggests duct tape andplastic, then wait forfurther officialinstruction. Although thetape and plastic methodwould offer someimmediate short termprotection from low leveltoxins at lowconcentrations, it wouldbe, at best, a short termsolution. Mostgovernments tend toonly recommendemergency proceduresthat can be afforded byall their citizens.
As a contrast to mostgovernments, bothSwitzerland and Israelrequire, and subsidizethe cost of, NBC saferooms in apartment buildings. They have strictstandards in place governing both theconstruction of the room and the ventilationequipment protecting the room.
For protection of some of our military personaland government officials, the U.S. Department ofthe Army - Corps of Engineers has standards bywhich NBC airborne toxic free areas must comply.These standards dictate the differential pressurein the safe room (protected space) as well as thedesign of the NBC filter/ventilation system.
The main reasons whyan un-pressurized roomwill not protect theoccupants for very longis that the room"breaths" - in otherwords, it leaks air bothin and out through thecracks as the externalatmospheric pressurefluctuates - due wind orother atmosphericvariables liketemperature, andbarometric pressureswings due toapproaching weatherfronts. Air constantlytries to normalize itspressure andtemperature betweendifferent variants - as itdoes this, it brings withit whatever that aircontains. Also, in asealed room, there is noaccommodation toreplenish oxygen andexpel the exhaledcarbon dioxide of theoccupants.
In order to create andmaintain overpressureas well as give the
required air exchanges to support the air supplyneeds of the sheltered occupants, a safe roommust be equipped with true positive pressureNBC filter/ventilation unit and a means of ametering the exhaust air out of the protectedspace.
American Safe Room filter/ventilation equipmentand related components are designed andmanufactured specifically for this purpose.
Fundamentals of a Protected Space
1. Through the wall kit2. Wall mount flange for hose -
included with the Safe Cell3. Intake hose: 5-inch diameter/60-
inches length - included with theSafe Cell
4. Safe Cell NBC filtration/ventilationunit
5. Emergency hand pump - shownmounted on the Safe Cell
6. Digital pressure monitor (externallink - scroll down)
7. Overpressure valve - ceiling mountalso available
8. 110/220 Volt AC outlet (standardwall plug) for the Safe Cell
9. User supplied 12-volt deep cycle(marine) battery - standardautomotive batteries also work
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
5
Blast Doorpage 20
Emergency Backup Hand Pumppage 10
12 vold DCautomotive ormarine battery(user supplied)
110 or 220 volt AC
50/60 hertzSafe Cell
page 7, 8
Blast Valvepages 18, 19
Overpressure Valve
pages 11, 12
Blast Valvepages 18, 19
Blast Hatchpage 21
Ventilation Pipes
page 17
Air intake hose
Critical Components of an Underground Shelter
The portals to the outside are the criticalcomponents that protect the occupants ofan underground shelter.
American Safe Room manufactures all ofthese items.
For more information, please see thespecification page for these items inthis catalog and download theinstallation and operation manualson our websites:
www.AmericanSafeRoom.comwww.AmericanBombShelter.com
Ventilation Pipes
page 17
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
6
110/220-volt ACpower cord
Mounting bolt
Wall mountingflangefor hose
Port seal (for storage)
Air outflow port
Air intake port
Portseal
Emergency Backup Hand Pump
Air intake hose
12-volt DCpower cordwith clip leads
12-volt DCautomotive ormarine battery
110 or 220-voltAC power source(wall outlet)
Safe Cell System Components
The American Safe Room Safe Cell NBC airfiltration systems are positive pressure NBCfilters designed to meet the critical requirementsof the US Army Corp of Engineer’s documentnumber ETL 1110-3-498 - Design of CollectiveProtection Shelter to Resist Chemical, Biological,and Radiological (CBR) Agents. This provendesign has been deployed worldwide togovernments, militaries, and civilians in blast andfallout shelters, command bunkers, and militaryvehicles. It has been submitted to the US StateDepartment who issued a Commodity Jurisdictionruling it to be a Class XIV munition by thebecause of it’s effectiveness in filtering warfaregases and particulates.
This series of filters all have a system airflowrating of 100 cubic meters per hour of filtered air.You can get them a variety of voltages fordifferent applications. See pages 7 and 8 formore information.
The Safe Cell and it’s related components havebeen especially designed with the end user andinstaller in mind. All components are turn keysystems - including all components, hardware,and step by step technical documentation foreasy installation.
Also available are the Iso-Shield 120 and theIso-Shield 800 particulate air filtration systems:
The Iso-Shield 120 is designed to create ahospital grade isolation room in anysuitably sized and sealed room.
The Iso-Shield 800 is designed to create aCDC grade isolation room in any hospitalroom.
Please note: not all systems haveevery feature shown above
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
7
DescriptionThe Safe Cell is an NBC air filtration systemdesigned to overpressure a protected space. Itmounts on a wall, connects to an air intake pipeand contains a bank of filters and a blower (fan).
This model features a built in power supply thattrickle charges a user-supplied 12 volt battery,automatically reverts to the battery when the ACpower drops out, then automatically reverts tothe AC when it comes back online, and thenautomatically recharges the battery.
Parts supplied with this item• Safe Cell air filter• Wall mount kit• Air intake hose• Wall mount flange for air intake hose• Electrical cords - AC and DC• Installation and operation manual
Price and Availability
Part number ASR-100-AV-NBC
Price $2,395.00/each
Availability Stock item
Specifications
Air flow - filtration mode 100 CMH (60 CFM)
Air flow - ventilation mode 200 CMH (120 CFM)
Noise level 60 dB(A)
Weight 49 pounds (22 kilograms)
Electrical - primary 110 – 240 volt AC
Electrical - backup 12 volt DC
Electrical - draw AC 2.5 amps at 110 VAC
Electrical - draw DC 4.3 amps at 12 VDC
Fuse AC 4 amps
Fuse DC 6 amps
Blower MTBF rating 2,000 hours
Safe Cell NBC Air Filter
Inches (millimeters)
For more information, please see the installationand operation manual for this item availableonline at: www.AmericanSafeRoom.com
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
8
AC only Safe Cells
Part number ASR-100-120V-NBC (120 volt AC)
Part number ASR-100-240V-NBC (240 volt AC)
Price $2,195.00/each
Availability Stock item
Safe Cells with external blowers
Part numberASR-100-120V-NB (120 volt AC only)
Part numberASR-100-240V-NB (240 volt AC only)
Price $2,195.00/each
Availability Stock item
DescriptionThis kit combines several of our productsdesigned to give you blast protected filtered airinside your underground shelter.
Parts supplied with this item• Safe Cell air filter - one each• 50 PSI Blast Valves - two each• Overpressure Valve - one each• Emergency Backup Hand Pump - one each• Installation and operation manuals
Price and Availability
Part number ASR-100-AV-NBC-COMP
Price $3,800.00/each
Availability Stock item
Safe Cell Options
Specialized VoltagesThe Safe Cell can also be purchased configured toonly operate off of a single voltage.The automatic switching power supply is notinstalled in these models:
DC only Safe Cells
Part number ASR-100-12V-NBC (12 volt DC)
Part number ASR-100-24V-NBC (24 volt DC)
Price $2,195.00/each
Availability Stock item
Blast Protected Filtration SystemThis kit has everything you need to outfit yourshelter. Shipping is included in the price on thisitem only.
For more information, please see the instillationand operation manual for this item availableonline at: www.AmericanSafeRoom.com
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
9
Replacement Filters
Hepa Filter Warfare Gas Carbon Adsorber
DescriptionThe nuclear grade HEPA filter is a special filter wehave made just for our application. Each HEPAfilter is individually tested to MIL-STD-282before it leaves the factory. The penetration andactual airflow rate are indicated on the label.Every HEPA filter is individually DOP tested.These filters are also UL rated.
Specifications
Media Glass micro fiber
Material Fire retardant particle board
Separators Aluminum
Bond Polyurethane foam
Gasket Neoprene - both sides
Factory test Certified 99.97% efficiency
Price and Availability
Part number ASR-50-HEPA
Price $335.00/each
Availability Stock item
Pre-Filter Set
Price and Availability
Part number ASR-50-PF
Price $55.00/set
Availability Stock item
DescriptionThe nuclear grade war gas adsorber is a blocksieve adsorption filter cell consisting of twocontainment medias and a center block ofblended granule nuclear grade war gas carbonand ASZM-TEDA.
This special blend of two kinds of activatedcarbon adsorbs warfare gases and radioactiveiodine in order to meet the requirements of USArmy Corps of Engineers ETL 1110-3-498standard for war gas removal.
Price and Availability
Part number ASR-50-HEPA
Price $395.00/each
Availability Stock item
For more information, please see the detail orderpage for these items at:www.AmericanSafeRoom.com
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
10
DescriptionThe ASR-50-BB Emergency Hand Pump willintroduce safe, breathable air into your protectedspace when all other electrical supplies havefailed. It slip-fits onto the top port of all modelsof the Safe Cell.
Parts supplied with this item• Emergency Backup Hand Pump• Installation and operation manual
Price and Availability
Part number ASR-50-BB
Price $315.00/each
Availability Stock item
Specifications
Material - housing ABS Plastic
Material - bellows Synthetic rubber
Weight 8 pounds (3.6 kilograms)
Internal volume 1216 cubic inches (19,927 cc)
Stroke length 10.75 inches (27 centimeters)
Emergency Backup Hand Pump
Inches (millimeters)
For more information, please see the installationand operation manual for this item availableonline at: www.AmericanSafeRoom.com
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
11
Overpressure Valve
DescriptionThe Overpressure Relief Valve is a diaphragmvalve that uses gravity to properly calibrate theopening pressure.
It is used to meter the air flowing out of yourshelter. The opening pressure of this valve hasbeen calibrated to work with the Safe Cell tocreate and maintain positive pressure in yourprotected space.
The valve is normally closed and opens when theair pressure inside the shelter has reached thefactory set release point of 0.3 inches of watercolumn.
These valves can either be mounted on a wall orceiling or directly onto a Blast Valve. Please seethe following page for the differentconfigurations.
Parts supplied with this itemNote: all parts are supplied with every valve forevery type of installation shown on the followingpage:
• Overpressure relief valve• Wall mounting plate• Straight adapter• 90 degree adapter
Price and Availability
Part number ASR-50-OP
Price $165.00/each
Availability Stock item
Specifications
Material ABS Plastic
Opening pressure 0.3 inches of water gauge
Maximum pressure 2.5 PSI
Weight 3 pounds (1.4 kilograms)
Please see next pagefor dimension drawings
For more information, please see the instillationand operation manual for this item availableonline at: www.AmericanSafeRoom.com
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
12
Overpressure Valve Configurations
Wall mount with Blast ValveWall mount
Ceiling mount Ceiling mount with Blast Valve
Inches (millimeters) Inches (millimeters)
Inches (millimeters) Inches (millimeters)
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
13
Automatic Ventilation System
DescriptionThe Automatic Ventilation System will providedaily unfiltered ventilation to an undergroundshelter in order to evacuate moisture and odors.
It mounts on a wall adjacent to the Safe Cell.
The quick connect hose allows easy operationusing the air intake hose from the Safe Cell andthe existing ventilation pipes.
The blower is a marine grade, long life airhandler that is controlled by the timer.
Parts supplied with this item• 250 CFM blower• Wall mount bracket and fasteners• Analog automatic timer
Price and Availability
Part number ASR-50-AB
Price $645.00/each
Availability Stock itemSpecifications
Air flow - blower rating 250 CFM
Power consumption - 120 volt AC 1.4 amp
Fuse 4 amps
Blower MTBF rating 10,000 hours
For more information, please see the installationand operation manual for this item availableonline at: www.AmericanBombShelter.com
The air intake hose attached to the Safe Cellair intake hose
The air intake hose attached to theventilation blower
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
14
External Blowers
DescriptionThese external blowers will slip into the top(outflow) port of any Safe Cell and draw airthrough the internal blower. They are rated forcontinuous duty in a marine environment.
The AC models have a switch and a fuse. The DCmodels are supplied with battery terminal clips.
Parts supplied with this item• One each blower
Price and Availability
Part number ASR-50-HD110 (110 volt AC)
Part number ASR-50-HD220 (220 volt AC)
Part number ASR-50-HD12 (12 volt DC)
Part number ASR-50-HD24 (24 volt DC)
Price $365.00/each
Availability Stock item
Specifications
Airflow - all models 250 CFM
Weight - 120/220 volt AC 8 pounds (3.6 kg)
Weight - 12/24 volt DC 6 pounds (2.7 kg)
Power consumption - 120 volt AC 1.4 amp
Power consumption - 220 volt AC .75 amp
Power consumption - 12 volt DC 11.5 amps
Power consumption - 24 volt DC 5.3 amps
MTBF rating 10,000 hours
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
15
Through the Wall Kit
DescriptionThis kit allows you to run a duct through aresidential style wall - with a quick connect fittingfor the Safe Cell on the inside and either aregister grill or a rain hood on the outside.
It also allows you to shut off the duct when yourfilter is not in use.
Specifications
Material ABS plastic and aluminum
Duct size 4 inches internal diameter
For more information, please see the instillationand operation manual for this item availableonline at: www.AmericanSafeRoom.com
Parts supplied with this item• Rain hood with insect screen• Ducting• Register grill• Fasteners• Installation manual
Price and Availability
Part number ASR-50-WD
Price $195.00/each
Availability Stock item
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
16
Automotive Bulkhead Vent Kit
DescriptionThe Automotive Bulkhead Vent Kit is designed tobe mounted through a wall of a vehicle. Itprovided a heavy duty splash resistant shroudoutside the vehicle and a quick connection fittingfor the Safe Cell inside the vehicle.
FunctionThis kit is used to supply an outside air source forthe 12 or 24 volt Safe Cell (ASR-100-12V/24V-NBC) in order to overpressure the crewcompartment. The cut off valve can be used toshut down the port when the filter is not inoperation.
Parts supplied with this item• External steel shroud• Gaskets - 2• Quick connect fitting (port)• Cut off valve• 90 degree fitting with connector• Mounting screws• Installation manual
Price and Availability
Part number ASR-50-AD
Price $495.00/each
Availability Stock item
Specifications
Material - outside shroud steel
Finish - outside shroud primer
Material - fittings ABS plastic
Material - cut off valve ABS plastic
Material - gaskets BUNA rubber
Inches
For more information, please see the installationand operation manual for this item availableonline at: www.AmericanSafeRoom.com
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
17
DescriptionThese welded steel ventilation ducts are built toorder in pairs - intake and outflow. They arerated for 50 PSI. There are drawings and aworksheet to fill out in the manual available onwww.AmericanBombShelter.com. Once we havethe dimensions and orientation you require, wewill send you a formal quotation for parts andshipping.
FunctionThe Ventilation Ducts provide a conduit for airintake and outflow. They must be used in pairsand Blast Valves are highly recommended for allblast resistant shelters. The mounting plate holediameter pattern is the same as the Blast Valves.
Parts supplied with this item• Ventilation Ducts• Concrete wedge anchor fasteners• Installation manual
Price and Availability
Part number ASR-50-VD
Price quoted for each installation
Availability Special Order item
Specifications
Material steel
Finish primer
Construction continuous weldment
Internal diameter 4 inches (101.6 mm)
External diameter 4.5 inches (114.3 mm)
Steel Ventilation Pipes
For more information, please see the instillationand operation manual for this item availableonline at: www.AmericanBombShelter.com
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
18
Blast Valve
DescriptionThe automatic double acting Blast Valves areused to protect the Safe Cell and the occupantsfrom the high pressure wave caused by a nearbydetonation.
These valves are designed to mount onto aconcrete wall or ceiling over the air intake andoutflow pipes with the included wedge anchors.
The internal valves are normally in the centralneutral position and then automatically slam shutwhen the initial blast wave from an nearbyexplosion hits and then automatically closes asecond time when the vacuum that follows thepressure wave hits.
The Blast Valves need to be used on every portalin your shelter. The air intake pipe and the otheron the air outflow pipe need blast protection andany other portal - such as septic vents.
Parts supplied with this item• One each Blast Valve• Concrete wedge anchors• Installation and operation manual
Price and Availability
Part number ASR-101-BV
Price $475.00/each
Availability Stock item
Specifications
Material - case steel
Material - valve assembly stainless steel
Material - bushings bronze
Material - seals BUNA rubber
Construction weldment
Closing pressure 0.5 PSI (3.5 kilopascal)
Maximum pressure 102 PSI (7 bar)
For more information, please see the installationand operation manual for this item availableonline at: www.AmericanBombShelter.com
Inches (millimeters)
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
19
DescriptionThis Blast Door is designed to withstand a 50 PSI(3.4 bar) pressure wave and a 14.5 PSI (1 bar)rebound load. It must be installed with the doorseated toward the pressure threat (usuallyoutward).
It is designed to be installed after the concretewall has been poured and cured. Once the door ispositioned and attached with the anchors, thedoor cavity is filled with concrete.
Parts supplied with this item• Complete blast door pre-hung on frame• Concrete wedge anchors• Installation and operation manual
Price and Availability
Part number ASR-50-BD
Price $3,695.00/each
Availability Special Order item
Specifications
Material - door 3/16 inch (7.9 mm) steel
Material - frame 1/4 inch (9.5 mm) steel
Material - bushings silicon bronze
Material - gas seal closed cell foam rubber
Construction Cut, formed and welded
Blast Door
Standard opening size shown.Custom sizes available.
32(813)
72
(1829)
6(152)
Inches (millimeters)
For more information, please see the installationand operation manual for this item availableonline at: www.AmericanBombShelter.com
American Safe Room, Inc.www.AmericanSafeRoom.com
2009 CatalogRevision A-05
20
DescriptionThe Blast Hatch is designed to cap a vertical riseron an underground shelter and give theoccupants protection from a 50 PSI (3.4 bar)pressure wave and a 14.5 PSI (1 bar) reboundload.
It is designed to be installed after the concreteriser has been poured and cured.
Parts supplied with this item• Blast Hatch• Concrete wedge anchors• Pneumatic lift strut• Lift strut anchor• Installation and operation manual
Price and Availability
Part number ASR-50-BD
Price $3,195.00/each
Availability Special Order item
Blast Hatch
1612
Specifications
Material - door 3/16 inch (7.9 mm) steel
Material - frame 1/4 inch (9.5 mm) steel
Material - bushings silicon bronze
Material - gas seal closed cell foam rubber
Construction Cut, formed and welded
Inches
For more information, please see the installationand operation manual for this item availableonline at: www.AmericanBombShelter.com