    Fire Tube Boiler

  • 8/13/2019 Amine Acid and Sour Gas Plant Experiences

    3/16

    MEA Solutio

    Saturated Steam

  • 8/13/2019 Amine Acid and Sour Gas Plant Experiences

    4/16

  • 8/13/2019 Amine Acid and Sour Gas Plant Experiences

    5/16

    MEA Reboiler

    MEA Stripper

    n

    Vapor

  • 8/13/2019 Amine Acid and Sour Gas Plant Experiences

    6/16

    LeanMEA Solution

    This is the conventional, industrial manner of generating food-grade CO2 in a continuous,controlled scheme.

     Note that the 15% MEA (wt.) solution is kept indirectly away from the very hot reboil hea by the use of a direct-fired reboiler. Although this method involves the cost of a conventi

     boiler, it eliminates a lot of the degradation products that are formed when MEA comes in

    temperatures in excess of 300 oF. It also allows for easy and convenient means to ensure

    the fuel combustion to produce as near a stoichiometric quantity of CO2 without worryingreboiler heat is affected. The amount of steam produced by this method is well in excess

    required in the MEA Reboiler and this fact enables the process to have sufficient steam avonly introduce an excess of steam into the reboiler (which ensures that acid gas loadingsreduced in the Stripper with ease), but it also provides steam for an MEA Reclaimer (whi

    ensures the non-corrosive state of the circulating solution and the efficient operation of the

    The application of a cheaper ("low capital investment") direct-fired reboiler in order to sa

    cost of the MEA reboiler reduces the Capital Investment of the plant, but it introduces ma

    and expensive maintenance and operating problems for the operator ("owner") of the plant

    fired reboiler can accelerate the degradation of MEA into a very corrosive state and causecorrosion problems in the reboiler as well as in all the rest of the equipment. This is a clas

    of getting exactly what you paid for. If the eventual owner is not interested in reducing hi

    and maintenance costs and other problems, then he/she doesn't pay attention to such impothat will return to threaten his operating profit margin in the end.

  • 8/13/2019 Amine Acid and Sour Gas Plant Experiences

    7/16

  • 8/13/2019 Amine Acid and Sour Gas Plant Experiences

    8/16

     steady, and

    t generatednal steam

    contact with

    maximum in

    about howf that

    ailable to notill be

    ch greatly

     plant.

    e the capital

    y serious

    . A direct-

    manysical example

    s operating

    tant details

  • 8/13/2019 Amine Acid and Sour Gas Plant Experiences

    9/16

    Nitrogen to

    Flue Gas

    Lean MEA Solution

  • 8/13/2019 Amine Acid and Sour Gas Plant Experiences

    10/16

  • 8/13/2019 Amine Acid and Sour Gas Plant Experiences

    11/16

      Atm.

    Condensate from LP Cooler-Condenser

    H1

    H2

    This height should be sufficiently high to

    allow effient condensate over flow from the

    bottom of the exhaust scrubber and allow

    for taking a solution sample for analysis.

    LP C

    CW Supply

    CW Return

    LP CO2 + Steam from CO2 Stripper

    This height, together with H2  should be

    related to the available pressure in the LP

    Cooler Separator and give sufficient packing

    height for efficent scrubbing.

  • 8/13/2019 Amine Acid and Sour Gas Plant Experiences

    12/16

  • 8/13/2019 Amine Acid and Sour Gas Plant Experiences

    13/16

      ooler-Condenser

    LP CO2 to Purification & Compression

    LC

  • 8/13/2019 Amine Acid and Sour Gas Plant Experiences

    14/16

    Some background on MEA use in CO2 removal processes:

    During the 1950 and 1960's the Liquid Carbonic Corporation (Chicago, Illinois) was the World's largest producer and distributor of

    Carbon Dioxide - as a liquefied product ("LiquiFlow") and as a solid ("Dry Ice"). During the 50's, it started to expand itsmarkets in Latin America and decided to install proven, state-of-the-art production plants there. It chose to enter into a purchase/supply

    arrangement with a company in Dallas, Texas named International Process Equipment Corporation ("IPEC"). IPEC was majority-owned

     by Mr. Robert Graff  who had a recognized and respected reputation for designing and building CO2 removal plants mounted on

    skids and capable of being easily transported and installed in under-developed locations.

    During the early 50's Liquid Carbonic engineers bought some surplus, skid-mounted Girdler CO2 generating plants that had been recovered

    from US Naval ships such as World War II air-craft carriers and they learned about the benefits of the skid-mounted design. The

    Girdler corporation had specifically designed these units during WWII to function on-board ships to produce CO2 for vital and

    important fire extinguishers applications on board. These Girdler plants used a direct-fired heater that burned fuel oil directly

    through a stainless steel helical coil inside the furnace. A 20% wt. MEA solution was circulated within the coil by stainless steel

    Peerless centrifugal pump. The hot, MEA solution was flashed into bottom of a generator tower packed with Rashig Rings. The

    generator tower stripped out the absorbed CO2 from the Rich MEA introduced at the top of the Rashig Ring bed. The generator tower 

    operated at 40 psig and this was sufficient pressure to send the Lean MEA in the generator sump to the top of the CO 2 absorber.

    This design worked very well, but it had notorious amine degradation problems caused by the direct-fired reboiler. This was not a problemfor the Navy; they merely dumped the degraded solution at sea and put in fresh MEA on a timed schedule.

    Liquid Carbonic had two Girdler plants with the above design: One at Maracaibo, Venezuela and another at Lima, Peru.

    The application of amines for CO2 removal was brought about by the discovery of helium containing carbon dioxide in Thatcher, Colorado,

    in 1922. Rodger R. Bottoms, a chemist and lieutenant commander in the Navy, developed a process to exploit this helium deposit

    economically by removing the carbon dioxide. In 1929 he synthesized an amine that removed the carbon dioxide from the helium in laboratory

    experiments. In 1930 he patented the amine process for the Girdler Corporation for the removal of CO2. In 1935, Robert A. Graff, was

    working for Mr. Bottoms as his laboratory assistant. They both were employed by the Girdler Corporation. Mr. Graff went on to form the

    Graff Engineering Company in Dallas, Texas employing all the know-how and experience he had accumulated in his association with

    R. R. Bottoms and Girdler. Bob Graf actively designed and fabricated amine skid-mounted plants for the Texas-Oklahoma-Louisiana-

    Typical Stripper 5/16" Plate, seal welded

    35 psig Steam

    Condensate

    Rich MEA, 200 oF

    Water-CO2, 5 psig & 228oF

    Lean MEALean MEA Drain & to Reclaimer

  • 8/13/2019 Amine Acid and Sour Gas Plant Experiences

    15/16

     New Mexico Oil Patch, removing CO2 and H2S. His plants employed both direct-fired reboilers and steam-heated reboilers.

    Some unique and innovative features that the IPEC skid-mounted MEA plants incorporated were:

    • The use of a conventional, fire tube boiler to generate the CO2 gas as well as low pressure steam (35-40 psig).

    All the steam generated was sent to a U-tube bundle in a kettle Reboiler that formed part of the Stripper (as shown

    in the illustration above) and all the produced condensate returned to the boiler BY GRAVITY. There was no condensate

     pump(s), condensate controls, deaerators, or condensate instrumentation. Since Bob Graff needed an MEA heat exchanger 

    and an MEA cooler, he placed these directly below the kettle Reboiler and in doing so, had to raise the reboiler and its

    steam tube bundle to a height that was normally above the top of the steam boiler. This made the application of condensate

    gravity return practical and efficient.

    • The CO2 stripper used no "fancy" trays or packing. There were approximately 10 trays used in the IPEC Stripper and

    each was nothing more than a circular, 5/16" carbon steel plate with a segment cut out. The segment was approximately

    15 to 20% of the diameter - depending on the size of the stripper and the CO 2 capacity. These Strippers worked well and

    never needed, inspection or maintenance. The design could not be more simplified.

    • All the condensate produced in the LP Cooler-Condenser down stream of the Stripper was collected a Vapor-Liquid

    Separator and the condensate was returned to the solution system via the sump of absorber. THERE WAS NO

    CONDENSATE RETURNED TO THE TOP OF THE STRIPPER AS SO-CALLED "REFLUX" . This not only

    worked very simply and trouble-free, it required no reflux pump, flow meter, vales, controls, and instrumentation.

    • IPEC incorporated an Amine Reclaimer - a means to re-distill a portion of the Lean Amine in order to precipitate out

    any heavy, polimerized amine products or degradation by-products. This device kept the solution working for very long

     periods without suffering corrosion in the basic carbon steel material that the plant was constructed out of. Corrosion

    was effectively kept under control to the degree that the Reclaimer was kept operating. This feature worked very well

    and practically due to the availability of steam from the boiler. With a direct-fired Reboiler, the use of a Reclaimer is not

     possible.

    Addition notes and background:

    When I took over the Lima, Peru operation in 1963, I made some major modifications to the existing 150 kg/hr CO2 plant. I converted

    the two-pass CO2 absorber into a one-pass tower and mounted a scrubber on top to use the LP condensate from the Cooler-Condenser 

    to scrub the exhaust gas exiting the absorber. MEA consumption dropped immediately to 1.0 kg/tonne CO2 produced.

    I undertook the design and fabrication of a 400 kg/hr CO2 combustion plant using a steam generator and a Chicago-Pneumatic, 3-stage,

    oil-lubricated reciprocating compressor. I fabricated all the rest of the equipment locally in Peru. I patterned my design using a lotof the IPEC design that I had seen and studied while running the Jamaica Carbonics IPEC plant in Kingston, Jamaica previously before

    arriving in Peru. I followed Bob Graff's basic concepts with some slight modifications. I employed plain solid Stripper plates, like IPEC.

    I tried 6 plates and then 10 and found no difference. I also used tunnel caps on six trays and found no difference. I used all the LP condensate

    to scrub absorber exhaust gas and this plant went on to achieve an MEA consumption of 0.5 kg/tonne CO2 produced - a record in Liquid

    Carbonic for a pure MEA CO2 plant. I also employed a 12-15% wt. MEA solution instead of 20%wt. and reduced all corrosion within the MEA

    circulation system. This plant went on to produce efficiently for approximately 24 years before being de-commissioned because it

    was no longer needed. The only exotic material of construction used in its fabrication was a 304 SS Reboiler tube bundle.

    After confronting some field practical problems with kettle Reboiler U-tube bundles in Jamaica, I redesigned the Lima Reboiler tube bundle.

    In Jamaica we discovered that it was practically impossible to obtain a U-Tube bundle perfectly aligned horizontally. Because of fabrication

    tolerances and measurements as well as bundle deformations and heat distortions, the U-shape ("hair pin") did not maintain itself

     perfectly while installed. This mean that the top tubes were either sometimes sloped upwards or downwards. This is an important anomaly

    that is not discussed nor contemplated in heat transfer texts or classrooms when dealing with steam being condensed in a horizontal hair pin.

     Note that should the hair pin be sloped UPWARDS, formed condensate in the top of the hair pin will have a tendency to drain BACK  towards

    the tube entrance and block the entry of fresh steam. And should the hair pin slope DOWNWARDS, the condensate will simply collect at the

     bottom of the tube's return and form a liquid blockage there. Either of these effects will hinder and ultimately cause reduced heat transfer and/or

    haphazard operation of the Reboiler. And this was exactly what was detected in the Jamaican plant operation. It was cured with the substitution

    of the conventional "U" tube bundle with a "V" type of fabrication - as shown in the illustration below.

    With this modification, the Jamaican and Lima Reboilers worked exactly as calculated and predicted, with no fluctuation in heat transfer.

    It will be noted by those engineers with some amine plant experience that the above designed operations are in distinct difference

    with designs and fabrications of such illustrious engineering firms like Fluor, Brown & Root, and many others who always propose and build

    Amine absorbers and Strippers with at least 20+ very sophisticated trays or packings. They also insist on employing a so-called "Reflux" of

    condensate on the CO2 Stripper. What none of the design or process engineers with these firms have ever been able to explain, prove, or

    calculate to me is the factual and engineering REASONS for doing what they do. They just do it that way because they have always done it.

    Yet, they cannot explain the logical and engineering need to have a so-called "Reflux" in what is nothing more than a stripping operation of a

    non-condensable gas from a liquid solution. What, if any, purpose there is in such a futile attempt is left unspoken. No one has yet to explain

    why the Reflux is needed at the top of a CO2 (or an H2S) stripper. The real truth is: IT ISN'T - AND NEVER WAS - REQUIRED . The

  • 8/13/2019 Amine Acid and Sour Gas Plant Experiences

    16/16

    many IPEC and Girdler plants that were built and operated have proven this throughout the last 70+ years. And I have followed this principle

    and proved it in all the plants I designed, built, and operated as well.

    What is really embarrassing is that practically all major text books on gas purification - as well as most authors of journal articles - fail to see

    or recognize this false and useless engineering design in amine plant design. All that a "Reflux" of condensate can accomplish in the CO2 stripper

    is a "scrubbing" of the ascending vapors in the top section of the tower in order to avoid entrainment of MEA in the overheads. But if that is a

    necessity, then why not design the stripper and its diameter such that there is no entrainment in the first place?   The Strippers I operated and

    designed never produced any entrainment - inspite of the inherent excess steam (water vapor) in the overheads due to using all of the boiler's steam

     production in the Reboiler tube bundle. Authors such as Kohl, Reisenfeld, Neilsen, Campbell, and Maddox - all intelligent and learned engineers - have

    failed to detect what is an obvious mistaken design that is useless and does absolutely nothing to improve an amine plant's operation. However,

    a guy like Bob Graff did spot this in 1950 and incorporated a much simpler and fool-proof method.

    If one goes to the trouble of using a McCabe-Thiele method of designing a CO2 Stripper, it will be quickly noted that building a CO2 Stripper with

    20 trays - whether bubble cap, sieve type, or valve type - is an IGNORANT ENGINEERING OVERKILL. There is definitely no need for so many

    trays in an MEA Stripper. And thank goodness for that! There are enough troubles and problems to worry about in an MEA process without having

    to put up with investment, care, and maintenance of so many engineered trays.

    The latest actors in Amine Plants - such as DEA, MDEA, and even aMDEA - have the characteristic of being selective in absorbing H2S with

     preference over CO2 and are actively used in Sour Gas applications. These solutions also demonstrate a propensity for easily having H2S stripped

    out of solution in the Stripper. Therefore, they should require less trays than even an MEA Stripper.