MERLIN® manufactures sustainable solar energy solutions for commercial, industrial and residential roofing, as well as transportation, portable and wearable applications. We believe that our unique solar energy solutions will make the world rethink what solar energy is capable of.
WHO WE ARE
UPGRADE YOUR ROOF WITH DURABLE, FRAMELESS SOLAR PANELS
Our solar panels can reduce, or even eliminate, your electricity bill with its enhanced energy output and efficiency. The simple peel and stick application makes the installation process inexpensive and quick. Our extremely light construction can eliminate the need to make structural enhancements to existing roofs. The frameless, low-profile design gives your roof a superior look while maintaining its durability.
IS YOUR ELECTRICITY BILL SOARING HIGH?
AN ENERGIZED ROOFMERLIN® ADVANTAGES
Class A fire rating
UL listed / IEC Approved / CEC listed
High performance levels
High strength
Stable reinforcement to the solar cell
Reliability of c-Si solar cells
Enhanced production in low / diffused light
Frameless, low-profile design
BENEFITS OF SOLARINTEGRATED ROOFING
Fast & easy peel and stick application
Low installation cost
Maximized tax credit benefit
Enhanced energy output
Superior aesthetics
High durability & reliability
CEC LISTED
CLASS A FIRE RATING
For further details, contact: MERLIN SOLAR TECHNOLOGIES, INC.
5891 Rue Ferrari, San Jose, CA 95138 | Ph: (408) 321-8258
E-mail: [email protected] | www.merlinsolar.com© 2019 Merlin Solar Technologies, Inc.
Distributed by:
TECHNICAL DATAElectrical Characteristics (STC)1
MERLIN® PV Module
Cell Type
Number in series
Rated Power (Pmax) W
V
A
V
A
A
VDC
°C
°C
%
%/°C
%/°C
%/°C
Voltage at Pmax (Vmp)
Current at Pmax (Imp)
Open-circuit Voltage (Voc)
Short-circuit Current (Isc)
Active Area Efficiency
Temperature Coefficient of Isc
Temperature Coefficient of Voc
Temperature Coefficient of Pmax
Maximum series fuse rating
Maximum system voltage
Nominal Operating Cell Temperature (NOCT)2
Operating temperature
Termination
Fire Rating Class A
Unit 160 165 170
36
160
18.78
8.53
22.91
8.85
18.19
36
165
19.11
8.64
23.10
9.01
18.76
0.05
-0.33
-0.42
15
600
52+/-2
-40 to +85
36
170
19.34
8.79
23.22
9.18
19.33
Mono Mono Mono
Jbox with PV cable and polarize connectors
1. STC standard test conditions: 1000W/m2 intensity, Air Mass 1.5, 25OC cell temperature. The power tolerance is -3% / +3% W, at STC. The electrical characteristics are within ±2. Mounting on metal flashing pan
IV Curves PV Module GX36S -16510
8
6
Cur
rent
[A]
4
2
00 5 10 15 20 Voltage [V]
25
Incident Irrad. = 1000 W/m2
Incident Irrad. = 800 W/m2
Incident Irrad. = 600 W/m2
Incident Irrad. = 400 W/m2
Incident Irrad. = 200 W/m2
165.4 W
132.3 W
98.9 W
65.3 W
31.9 W
Width
Length
UL Standard 1703
IEC 61215/61730
Warranted upto 25 years
Materials and workmanship 5 years
Power output 25years
QUALIFICATIONS
90% of nominal rated power for years 1-10
80% of nominal rated power for years 11-25
Units
mm / kg
in / lb
Length Width Thickness*Weight
1024
40 5/16
987
38 7/8
4.5
3/16
21.5
17/20
8.84
19.5
Physical Characteristics
*Panel at the junction box area 21.5mm or 7/8 inch high.
without J-boxwith J-box