AN EVALUATION OF PROTOTYPE SEATS USG BIOR-P3 AND HYBR III WITH TRID NECK ABSTRACT Toshihiro Ishikawa, Naoki Okano, Kazutaka Ishikura Koshiro Ono* Mazda Motor Corporation *Japan Automobile Research Institute There has been some discussion on whether Hybrid III can accurately evaluate the risk of low- severity neck injuries in rear impacts because it has been developed f or the evaluation of frontal impacts. A new dummy with an articulated spine and a flexible torso has been developed. The newest prototype, BioRID-P3 has been compared with volunteer data at Delta V(DV)9km/h and it was und to respond with a good biofidel ity. The object of this study is to clari the difference of response between the BioRID and the Hybrid III from tests using prototype seats at DV 1 Skm/h. The characteristics of human kinematics which were confirmed in lower speed BioRID tests were also confirmed at DV1 5km/h. The upper neck shear forces and moments and NIC of the BioRID were signif icantly different from those of Hybrid II I. KEY WORDS REAR IMPACTS, WPLASH, DUMMIES, SEATS, SLED TESTS NECK JURIES THAT OCCUR mainly in low speed rear impacts a re the most frequent inj uries in traffic accidents. These injuries a re classified as AIS 1 and are not life threatening, but 1 0% of them lead to long term consequences. These injuries are very complex and the occurrence mechanism, which is not lly understood at present, is the subject of several ongoing research studies. Some manucturers have used a currently available dummy (Hybrid III or Hybrid III equipped with a TRID neck (Thunnissen et al„ 1996)) to evaluate new seats developed and introduced to reduce the risk of neck injuries. By the way there has been some discussion on whether Hybrid III can accurately evaluate the risk of low-severity neck injuries in rear impacts because it has been developed f or the evaluation of fronl impacts. For example, its neck and torso are stiff and unlikely to interact with the seatback in the same compliant way as those of a human (Davidsson et al. 1998) . In these situations a new dummy with a good biofidelity is required to clari the occurrence IRCOBI Conference - Montpeer (France}, September 2000 379
Transcript

AN EVALUATION OF PROTOTYPE SEATS USING BIORID-P3 AND

HYBRID III WITH TRID NECK

ABSTRACT

Toshihiro Ishikawa, Naoki Okano, Kazutaka Ishikura Koshiro Ono*

Mazda Motor Corporation *Japan Automobile Research Institute

There has been some discussion on whether Hybrid III can accurately evaluate the risk of low­severity neck injuries in rear impacts because it has been developed for the evaluation of frontal impacts. A new dummy with an articulated spine and a flexible torso has been developed. The newest prototype, BioRID-P3 has been compared with volunteer data at Delta V(DV)9km/h and it was found to respond with a good biofidelity.

The object of this study is to clarify the difference of response between the BioRID and the Hybrid III from tests using prototype seats at DV 1 Skm/h.

The characteristics of human kinematics which were confirmed in lower speed BioRID tests were also confirmed at DV1 5km/h. The upper neck shear forces and moments and NIC of the BioRID were significantly different from those of Hybrid III.

KEY WORDS REAR IMPACTS, WHIPLASH, DUMMIES, SEATS, SLED TESTS

NECK INJURIES THAT OCCUR mainly in low speed rear impacts are the most frequent injuries in traffic accidents. These injuries are classified as AIS 1 and are not life threatening, but 1 0% of them lead to long term consequences. These injuries are very complex and the occurrence mechanism, which is not fully understood at present, is the subject of several ongoing research studies. Some manufacturers have used a currently available dummy (Hybrid III or Hybrid III equipped with a TRID neck (Thunnissen et al„ 1996)) to evaluate new seats developed and introduced to reduce the risk of neck injuries. By the way there has been some discussion on whether Hybrid III can accurately evaluate the risk of low-severity neck injuries in rear impacts because it has been developed for the evaluation of frontal impacts. For example, its neck and torso are stiff and unlikely to interact with the seatback in the same compliant way as those of a human (Davidsson et al. 1998).

In these situations a new dummy with a good biofidelity is required to clarify the occurrence

IRCOBI Conference - Montpellier (France}, September 2000 379

mechanism of neck injuries in rear impacts and develop the seats which can reduce the risk of neck injuries. Therefore a Swedish consortium began developing a dummy prototype with an articulated spine and a flexible torso and with human-like surface contours based on the work of Schneider et al. ( 1 983). The newest prototype is called BioRID-P3, referred to as "BioRID" in this paper. The BioRID has been compared with volunteer data at DV9km/h and it was found to respond with a rather good biofidelity. (Davidsson et al. 1 998)

However it has not been discussed enough that the BioRID could also be biofidelic at velocity changes higher than DV9km/h, which are often used in the evaluation of seat performance for neck injury risk in rear impacts. lt is not clear whether the BioRID can properly evaluate the differences between seat structures. Furthermore the differences of response between the BioRID and the Hybrid III in the evaluation of seat perforrnance has not been discussed. The objects of this study are; ( 1 )To confirrn that the BioRID shows human-like kinematics at DY 1 5 km/h, a higher velocity change thanDDV9km/h. (2)To clarify the differences of response between the BioRID and the Hybrid III from tests using prototype seats. (3)To identify the points which need attention and should be improved for the evaluation by each dummy.

MATERIALS AND METHODS

This section presents the test conditions and the seat specifications. A total of nine tests were conducted using both dummies, and their results were compared to each other. A prototype seat was mounted on a target sied. A dummy was seated in normal position without seat belt. A DVI Skm/h was chosen to represent a middle value from the velocity changes which are often used to evaluate seat performance for the risk of low-severity neck injuries in rear impacts. The five tests with the BioRID were conducted at Japan Automobile Research Institute (JARI) in cooperation with JARI and Chalmers University. The four tests with the Hybrid III with TRID neck were conducted at Mazda. Figure 1 shows the sied acceleration pulses used. All of the tests were conducted with the head restraint. In all tests the initial distances between the head and the head restraint are about 50mm and the seatback angles are the same (design angle). The BioRID was dressed in the special shirts and pants (made of Lycra) recommended by Chalmers University. The Hybrid III was dressed in normal cotton clothes.

Four kinds of prototype seats, whose structures were changed to affect the risk of neck injuries, were used. The test number and the specifications of the prototype seats are shown in Table 1 . Seatl is a production front seat of a small passenger car. The seat back stiffness of Seat2 is lower than that of Seat l . Seat3 has the same modifications as Seat2 and also has a stiffer recliner system. The head restraint of Seat4 was designed to move forward and upward by the occupant's inertial force. The stiffness of the seatback and the recliner of Seat4 are nearly same as those of Seat3.

The accelerations of the head, T l , T8 and pelvis were measured by the standard accelerometers. The upper neck load cell of the BioRID and the upper and lower neck load cells of the Hybrid III

measured the neck loads. The dummy tests were recorded by high-speed video (500 frames/s) and each of the frames were digitized and smoothed. Figure 2 shows the test configuration and the positive direction of displacement, acceleration, angle and neck loads.

380 IRCOBI Conference - Montpellier (France), September 2000

Test Name No.

1 Seatl 2 Seat l 3 Seat2 4 Seat3 5 Seat4 6 Seatl 7 Seat2 8 Seat3 9 Seat4

RESULTS

+

Table 1 - Test number and specification of prototype seats Specification Structure inside recliner

seatback frame No modified rigid wire one side No modified rigid wire one side Soft seatback spring one side Soft seatback & hard recliner spring both side Movable head restraint spring both side No modified rigid wire one side Soft seatback spring one side Soft seatback & hard recliner spring both side Movable head restraint spring both side

40

� 20 .s 0 c: ·B -20 � -40 .Ol „ u -bO u

"" -60 -100

0 50 100 150 200 tin e m sec)

Fig. l - Sied pulses for BioRID and Hybrid III

Neck Loads

Acceleration, Displacement

+Z

Shear Axial Moment Angle

Initial position � : Tension Flexion

Fig.2 - Test configuration and the positive direction of measurements

Dummy

BioRID BioRID BioRID BioRID BioRID Hybrid III Hybrid III Hybrid III Hybrid III

REPEATABILITY OF BIORID: Two tests were conducted with Seat l at DV 15km/h with the BioRID to confirm its repeatability. Figure 3 shows the test results. All the figures indicate that the two time-history curves of each response correspond almost exactly indicating the good repeatability of the BioRID. The video analysis, not shown in this paper, also confirms the good repeatability of the dummy.

IRCOBI Conference - Montpellier (France), September 2000 381

100

50

0

"'..,, . 50

'E . ioo . 150

. 200

. 250

100

50

N 0 "' 'E . 50

. 100

. 150

100

50

N"' 0

'E . 50

. 100

. 150

Head acceleration

rrm - x-Test2

- z-Test2

- X-Testl

- 7.-'l'P.stl

0 50 100 150 200

Time (msec)

Tl accelerat1on

f�l� - x-Test2

- Z-Test2

- X-Testl

- 7.-1'P.1'tl

0 50 100 150 200

Time (msec)

Pelvis acceleratron

rw�� - X-Test2

- z-Test2

- X-Test!

- Z-'l'P.1't 1

0 50 100 150 200

Time (msec)

5 z

U pper neck 11 011 ent

�j [-l--T;1§ -10 ·--·--·------L--·-- - - -----·- . . . 0 so 100 lSO 200

Tin e <m sec>

U pper neck shear force

. _;:� 0 so 100 lSO 200

T in e <m sec>

U pper neck axial force

0 so 100 lSO 200

Tin e <m sec l

Fig.3 - Repeatability of BioRID

� tJ.

� tJ.

KINEMATICS CO:MPARISON OF BIORIDIHYBRID III: lt is said that the main differences between the kinematics of a human and the Hybrid III in low speed rear impacts are the following three items. 1) Head lag: The head of a human has a slight flexion motion early in the impact and an extension motion which occurs later in the impact, after that seen with the head of Hybrid III. ii) Ramping-up: The human H-point ramps further up !arger along the seatback than that of Hybrid III. iii) Straightening of the spine: The human spine straightens due to kyphosis. Figure 4 compares volunteer, BioRID and Hybrid III results at DV9.3km/h from a study by Chalmers University (Davidsson et al. 1999).

Figure 5 similarly shows the results from this study (Seat l , DV1 5km/h ). The relative rotation angle between the head and T l for the Hybrid III indicates slight flexion motions by about 70msec. After that, the Hybrid III trace indicates an abrupt extension motion, while the BioRID flexion motion continues until 200msec. This difference is similar to that at DV9 km/h. Though the BioRID results of the Chalmers study show an extension motion which occurs later than that of the Hybrid III, in this study the BioRID does not go into extension at any time during impact. The reason for this difference is that the seat used in the DV9 km/h test did not have a head restraint, while the seat for this study did and it supported the head throughout the impact.

Next the ramping-up results, which are expressed by the H-point upward displacement, are compared. The upward displacement at DV15km/h is !arger than that at DV9 km/h. The displacement

382 IRCOBI Conference - Montpellier (France), September 2000

of the BioRID is !arger than that of the Hybrid III. The difference between the dummies is similar to the results at DV9km/h. Finally the straightening of the spine which is calculated as the change in absolute distance between the H-point and T l is compared. The distance change at DV15km/h for the BioRID is similar to that at DV9km/h. The change for the Hybrid III is not shown in Figure 6 because the spine of Hybrid III is not straightened as it is one rigid body. The above results are those of Seat l . Similar kinematics were seen with the other seat configurations.

Relative rotation angle between head and T l

30 1 j 10

1 � o�-: i 'E 25

) g .: � 20 . . ; i ·10

;; _; ·20 . · � : ·30

Ir � 1s ! Volunteer � ! 10

H-point upward displacement

·10 1....-.......... _ _.___. _ _.__...____.

so 100 150 200 2SO 300 0 Ttme (ms)

so 100 ISO Time {ms)

200 250 300

•O

� ­i !30

„ _ . ... � "gZO � . =6 : ö ü 1 0 . . „ . � � .e -o 0

Change in absolute distance between H-point and Tl

·10 1....-.......... _.....___. _ _.__.__ ......

0 so 100 ISO Time(ms)

200 250 300

Fig.4 - Kinematics comparison at low speed (Rigid seat, DV9.3km/h, without head restraint) Source: Johan Davidsson et al.: A Comparison between Volunteer, BioRID P3 and Hybrid III

performance in Rear Impacts. IRCOBI Conference-Sitges(Spain), September 1999 Relati.<! rotatDn �"l! between head "1d n

007

OOb

005

00�

Oll3 " 002

! -w f----+---'1---+-� -ei

OOl

-om

-30 -002

so zoo 0

HP z-di;pBc:l!m ent

50

1 ---

J.00

till e '11 secl

�so 200

Ch<roge h <b51J)Jte dist.n:e bl!tween H•poht a'ld H

003 o�s i----i----+---Hn-r-­o� f----+---1--.1"""'�t­

om.s f---+---+.lM-F-t--tflih e OOl. l---+----+---1---v

0005 �-4-,rJll.lc.;.---+--­O lil"""'WhiWM'-l--t---+--�

-0005 1-------+---t----; -001

0 .50

Fig.5 - Kinematics comparison at higher speed (Seatl , DV1 5km/h, with head restraint)

COMPARISON OF BIORID/ HYBRID III RESPONSES: The time history curves of the accelerations and neck Ioads of the BioRID and the Hybrid III are compared. Figure 6 shows the results of Seatl at DV 15km/h. The thick lines show the results of the BioRID and the thin Iines show those ofthe Hybrid III. The lower neck loads ofthe Hybrid III are also shown in the same figures.

The left side of Figure 6 show the acceleration comparisons. The BioRID sied acceleration increases more slowly and peaks Iater than that of Hybrid I I I . Therefore all the accelerations of the BioRID also increase more slowly and peak later than those of the Hybrid III. Except for this phenomenon, no clear differences between the BioRID and the Hybrid III accelerations were seen. A

similar thing can be said about the NIC. The NIC formula is shown below. NIC=(Ar1 -Ahead)*O .2+(V n-Y1iead)2

An: Tl x-acceleration, Ahea1: Head cg x-acceleration, 0.2: Length, Yn: Tl x-velocity, Yhead: Head cg x-velocity

IRCOBI Conference - Montpellier (France), September 2000 383

0 50

0 50

0 50

0 50

Head acceleration

100

Time (msec)

150

TS acceleration

100

Time (msec)

150

Pelvis acceleration

100

Time (msec)

150

Sied acceleration

100

Time (msec)

150

200

200

200

200

- X· Hybridlll

- z. Hybridlll

-X· BioRID

-z. BioRID

- X· Hybridlll

-Z· Hybridlll

- X · BioRID

-z. BioRID

- X · Hybridlll

- z. Hybridlll

- X· BioRID

- Z · BioRID

1- Hybridlll

- BioRID

0 so

Neck Shearfon:e

],00 Till e wsec>

],50

N eck A x:i:llfon:e

200

1000 ----·-· ---···-·--· -·---- -----i 600 t-----+--->--,-/1..-+--�I bOO t----+--+--'1-iHf-l+----!

z �00 fl '( ! 200 ·4 ' '\ ' 1

0 < �-..:-' \i!\! l""�·l -200

0

0

0

____ :_ ___ J __ v _ _ :1___'._J 50

50

50

100 T ill e wsec>

150

Neck M oment

100 Till e � sec>

N J:

100

Time (msec)

150

150

200

200

200

- Low-Hybrjjm - U p-Hybrilm - BhRll>

- Low-H ybrjjlll - U p-H ybrilm - BhRll>

- Low -H ybrilm - U p-H ybrilm - B hRll>

Fig.6 - Comparison of measurement results of BioRID/Hybrid III (Seatl , DVISkm/h)

Next is a comparison of the neck loads. Two differences between the BioRID and the Hybrid III were found. One is that the peak value of the BioRID shear force is half or less than half of that of the Hybrid III. The other difference concerns the neck moments. After the initial flexion moment of the Hybrid III peaks at about 130msec, it changes to an extension moment which peaks at about 1 60msec. On the other hand, the moment of the BioRID indicates a flexion moment and does not change to an extension moment. The results of Seat l were described here and similar results were found with the other seats.

Next the peak values of the accelerations and neck loads of the BioRID are compared with those of the Hybrid III in Figure 7. The horizontal axis shows the accelerations of head, ehest and pelvis and neck loads and NIC. The vertical axis shows the ratio of the value ofthe BioRID to that of the Hybrid III (R810). The values for the four different kinds of seats are shown for each item. The difference

384 IRCOBI Conference - Montpellier (France), September 2000

between the sied pulse of the BioRID and that of the Hybrid III is corrected by the ratio of the peak values of sied accelerations. The R810 formula is shown below.

1 fi

1 b

1 J.f

1 2

0 1 H CD 0:: 0 fi

O b

O J.f

0 2

0 X N < < <

"O "O .µ ro ro VI Cll Cll Cll :I: :I: ..c:

V

GBio: Peak value of sied acceleration for BioRID GHvs: Peak value of sied acceleration for Hybrid III As10: Peak value ofBioRID AHvs: Peak value of Hybrid III

C om parison o f B :DR 1D /H ybri:lm

< � � ...... � V VI VI u 1.. u ro u .µ H

.µ ..... ..... Cll ro Cll ..... Cll c: z VI ::> ::> z Cll z X z Cll Cll ...... ...... 1 ..c: 6. < 1 e ..c: Cll Cll a. Vl a. 0 V a. a. ::::> ::::> ::::> :c:

Fig.7 - Comparison ofthe peak values

---+-- S e at1 --- S e at2 -.tl- S e at3 -e- S e am

Previously, it was mentioned that the peak value of the BioRID's shear force is half or Jess than half of that of the Hybrid III for Seat 1 . Figure 7 shows that for all four seats the shear forces are also half or less than half of those of the Hybrid III. Some of the other BioRID values (ehest z-acceleration, pelvis x-acceleration and upper neck moment) are Iarger than those of the Hybrid III ( l or over) and some (head z-acceleration, ehest x-acceleration, upper neck shear force and upper neck axial force) are smaller ( l or Jess). Looking at the NIC values, for two seats the BioRID peaks are Jarger than those of the Hybrid III, while those of the other seats are smaller. The order of the peak value ratios for each seat is not always the same.

Finally the change of each peak value due to the change of the seat structure is compared. The NIC and upper neck Joads from the recorded responses are considered as primary indicators of neck injury risk. Figure 8 shows the results. The horizontal axis shows the seat type and the vertical axis shows the ratio of the peak values to those of the Seat l . The left graph shows the results of the BioRID and the right shows the Hybrid III. The lower neck moments of the Hybrid III are also shown in the right graph. Though the values tend to gradually decrease in the order of Seat l , Seat2, Seat3 and Seat4 for both dummies except for the upper neck moments of the Hybrid III, the degrees of change are different. The upper neck moments of the Hybrid III in this figure show the initial flexion moments to compare with those ofthe BioRID.

IR CO BI Conference - Montpellier (France), September 2000 385

B ilRID

1 )f --------·---·--------·----·-------·--------·---·

� 1 2 t-----------------< „ � 1 1---a,,-----------___, „ „

VI O ll t-----'� .......... -�=-.------] j Ob VI 0 )f f----------"�---"'!i!=---.0..�----i B -� 0 2 a::

SEATl SEAT2 SEAT3 SEAT4

Hybrid III 1 )1 ·-------··---·---·-·--------·-··· ·-·-···---·--···-·-··--··-1

/....._ i lc 1-----.,...::.___ __ __::,,._ ____ __,

l r---����""":::::::---:i..-----., �-----� -+- U p-neck shear -il- U p-neck A x>il -.-.. U p-neck m om ent -•-· L ow -neck

Oll i--------------'N"!.__� �-*"---N �"--------'

SEATl SEAT2 SEAT3 SEAT4

Fig.8 - The change of the peak values by seat structures

DISCUSSION

KINEMATICS OF DUMMIES: The BioRID dummy exhibits human like kinematics at DV l Skm/h as described previously. In this section the kinematics seen with the different dummy structures are discussed. First the relative rotation angle between the head and Tl is discussed. Figure 9 shows the time histories of the head angle and the T l angle, which the relative rotation angle is calculated by. The left graph shows those of the BioRID and the right shows the Hybrid III. Each seatback angle is also shown in the same graph.

B ilRlD H ybhlm

20 20

10 10

0 0 - T l ang:E Cll

-10 Cll

E - H ead ang:E E -10 O'I O'I Cll -20 - H ead-T1 ang:E Cll -20 -0 -0

-30 - S eatback ang:E -30

-40 -40

-so -50 �--�------ ----

0 50 100 150 200 0 50 100 150 200

tin e Cm secl tin e Cm sec l

Fig.9 - The relative rotation angle between head and T l and the angles of head, T l and seatback

This figure indicates that the T l rearward rotation of the Hybrid III ends at the same time (about 90msec) the rearward rotation of the seatback ends. The reason is considered to be that the T 1 of the Hybrid III can not rotate past the rotation of the seatback because the thoracic spine of Hybrid III is a rigid body. The head, however, can continue to rotate rearward because it is attached to a deformable neck. Consequently the relative rotation angle between the head and T l increases rapidly. On the other hand the T l of the BioRID continues to rotate rearward after the seatback stops rotating. The reason is that the BioRID's thoracic spine consists of individual vertebrae, like a human's spine, which can move with respect to one another. This phenomenon results in a small change of the head relative to

386 IR CO BI Co11ference - Mo11tpellier (Fra11ce), September 2000

T l rearward rotation. The heads of both dummies contact the head restraint around 1 OOmsec (BioRID: about 1 20msec, Hybrid III: about l OOmsec) and the head angles begin to decrease at the time the X accelerations ofthe heads peak. (BioRID: about 1 50msec, Hybrid III: about 1 30msec) In this study, no significant difference in the kinematics between both dummies was found during the contact between the head and the head restraint. lt is necessary to perform further analysis to explore any differences.

lt is weil known that the increase of the distance between the H-point and the T l is due to the straightening of the spine kyphosis, which occurs by the contact force of the spine with the seatback. One of the reasons that the H-point upward displacement of the BioRID is !arger than that of the Hybrid III seems to be due to the special shirts and pants for the BioRID which represents the movement between the skin and bones of a human. In this study the influence could no be clarified. lt is necessary to investigate the influence including the difference of the spine structure also.

As mentioned above, the BioRID dummy succeeds in showing much closer kinematics to a human than that of the Hybrid III indicating a better Jevel of biofidelity. From this point, the BioRID dummy seems to be an effective tool to evaluate neck injuries in rear impacts of these speeds.

COMPARISON OF BIORID/ HYBRID III RESPONSES: This section discusses the comparison results of the responses of the BioRID and the Hybrid III. First is the cause for the difference of the peak values of shear forces. Though the cause seems to be due to the difference of the neck structures (the neck of BioRID is softer than that of Hybrid III), we could not identify it in this study. Next is the cause for the difference of neck moments. lt is due to the difference of the kinematics because the difference agrees with that of the relative rotation angles between the head and T l that were described before. Further research is necessary because the upper neck loads of both dummies are very different from each other. From the video, it can be seen that the lower neck of the BioRID has an extension motion similar to the Hybrid III. lt is desirable that the lower neck loads of the BioRID will be ab Je to be measured and evaluated further because the Jower neck Joads also seem to be important for the evaluation of neck injury risk in rear impacts.

Next we would like to discuss the change of each peak value due to the change of the seat structure. If the relationship between one value of the BioRID and that of the Hybrid III is consistent, it is possible to evaluate the seat structure with either the BioRID or the Hybrid III. The relationship for each response however is not always the same, as shown in Figure 7 and 8. The differences between Seat3 and Seat4 are analyzed in more detail here. Though the NIC and upper neck shear force of the BioRID with Seat4 are !arger than those with Seat3, those of the Hybrid III are smaller with Seat4 than those with Seat3 . Since this phenomenon Jeads to opposite conclusions regarding seat performance with respect to risk of neck injuries, we should pay attention when we evaluate neck injuries using these dummies. The causes are discussed. The changes seen in the upper neck shear forces responses are similar to those seen in the NIC, therefore it is assumed that the causes for these changes are the same and only the NIC is discussed. The left side ofFigure 1 0 shows the NIC time histories and the Tl and head accelerations of the Hybrid III which are used to calculate the NIC. This figure shows that the Tl accelerations seen with Seat3 and Seat4 increase gradually after 20msec and the initial difference due to the seats is small. Focusing on the head accelerations, it can be seen that the head restraint of Seat 4 starts supporting the head earlier than that of Seat 3 , consequently reducing the NIC.

IRCOBI Conference - Montpellier (France), September 2000 387

50

"'111 -so .....

X-A ccel:!ret:bn o f H ead and T1 IHybr.i:llID

e -100 l----t---""lc-"=.\4,;-...,l=l'----t-----1 - H ead CSeat3>

X-A cceErstbn of head and T1 Q3 bRlD l

50 -··-··--·-·--·--·-·· ·-·--·-······--·-·········· -·-·-·······--·-·-···-· ·-···-·-·-··--··-··-····-, '

0 1----....:1� ...... --c--f--�--.Ji---:;""""� --- T1 CSeat3> ·50 r-----t--'\"--ti�T-:-:---'l''-f--. - H ead CSeat'll

- T 1 CSeat'll ·100 -150 i----+-----+--t---+----< i -150 -200

D 50

20

10

"'111 "'' D e

-10

-20

0 50

100

T in e Cm sec)

N X: IH ybri:IJID

100

T in e Cm sec>

150

150

______ J 200

200

--Seat3

--Seat4

"'vi ..... "' e

0 50

-20

o so

Fig. 1 0 - Head acceleration, T l acceleration and NIC

100 150 200 N X:

100 150 200

Tin eli!lm sec)

Similarly, the right side of Figure 1 0 shows the BioRID results. This figure indicates that the head is supported by the head restraint of Seat4 earlier than that of Seat3, similar to the Hybrid III. With Seat4 the T l acceleration becomes !arger than that of Seat3 after about 60msec. The increase is sharper than that of the Hybrid III. This sharp T l acceleration increase results in an increase in the NIC response of Seat4. The cause for the sharp increase ofT l acceleration of the BioRID is further analyzed. Figure 1 1 shows the T8 acceleration of the BioRID, which represents the acceleration at the center of gravity of ehest. The T8 acceleration does not increase sharply unlike that of the T l . The Hybrid III does not exhibit the same difference between the upper and the center of the thoracic spine because it is a rigid body. This seems to be one of the characteristics that is caused by the segmented spine of the BioRID. If this phenomenon also occurs with the human spine, which has a segmented structure like the BioRID's, the use of the NIC with the Hybrid III dummy for the evaluation of neck injury risk should be limited.

The reason that the T l acceleration increases sharply when tested on Seat4 in this study is discussed next. lt is due to the movement of Seat4. The upper part of the seatback of Seat4 moves slightly forward during impacts since the whole seatback moves to Jet the head restraint move forward and upward. (Figure 1 2) This movement results in the sharp increase ofT l acceleration seen with Seat4.

so 0

"'III -so ..... - r a i:s eat4 >

e -100

- T 8 1Seat3>

-1SO

-200 a so 100 150 200

T in Fig. 1 1 - T8 x-acceleration (BioRID)

388 IR CO BI Con/erence - Montpellier (France), September 2000

Fig. 1 2 - The movement of seatback of Seat4

CONCLUSIONS

From what has been discussed above, we can conclude the following: ( 1 ) The BioRID dummy shows good repeatability atDV1 5km/h. (2) The characteristics of human kinematics (i. head lag, ii. H-point upward displacement, iii. Spine

straightening) which were confirmed in lower speed (DV9km/h or less) BioRID tests were also confinned at a higher speed (DV 1 5km/h) of which is often used to evaluate the risk of neck injuries.

(3) The largest difference between the BioRID and the Hybrid III is that of the relative rotation angle between the head and T l , that of the BioRID does not exhibit an extension motion. The reason is that the T l can rotate rearward after the seatback stops rotating due to the segmented spine structure of the BioRID.

(4) From the above three points, the BioRID dummy seems to be an effective tool to evaluate the risk of neck injuries in rear impacts ofthese speeds.

(5) Further research in the following areas is necessary in order to evaluate the risk of neck injuries; the cause ofthe difference between the upper neck loads of the BioRID and the Hybrid III, and the possibility of measuring lower neck loads with the BioRID.

(6) lt was found that the NIC response of the BioRID responds differently than that of the Hybrid III when exposed to different seat structures. The reason is that Tl acceleration response of the BioRID is more sensitive to the change in seat structure than that of the Hybrid III because of the segmented spine of the BioRID.

ACKNOWLEDGEMENTS

I would like to thank Chalmers university for offering BioRID dummy and adjusting and setting it in this study.

IRCOBI Conference - Montpellier (France), September 2000 389

REFERENCES

Davidsson J., Flogars A., Lovsund P„ Svensson M.Y.: BioRID P3-Design and Performance Compared to HybridIII and Volunteers in Rear Impacts at DV=7km/h, Proc. 43rd STAPP Car Crash Conf„ San Diego, Califomia, 1 999, Paper No.99SC 1 6, pp.253-264.

Zuby D.S„ Vann D.T„ Lund, A.K.: Crash Test Evaluation of Whiplash Injury Risk. Proc. 43rd STAPP Car Crash Conf„ San Diego, Califomia, 1999, Paper No.99SC 18, pp.267-278.

Ono K„ ltami S„ Kaneoka K„ Gotou T„ Kisanuki Y„ Sakuma S„ Miki K.: Relationship between Localized Spine Deformation and Cervical Vertebral Motions for Low Speed Rear Impacts Using Human Volunteers, Proc. 1 999 Int. IRCOBI Conf. on the B iomechanics oflmpact, Barcelona, Spain, 1 999, pp.149-164.

Davidsson J„ Lovsund P„ Ono K„ Svensson M.Y„ Inami S.: A Comparison between Volunteer, BioRID P3 and HybridIII performance in Rear Impacts, Proc. 1999 Int. IRCOBI Conf. on the Biomechanics of lmpact, Barcelona, Spain, 1 999, pp. 1 65-1 78.

Eriksson L„ Bostrom 0.: Assessing the lnfl uence of Crash Pulse, Seat Force Characteristics, and Head Restraint Position on NICmax in Rear-End Crashes Using a Mathematical BioRID Dummy, Proc. 1999 Int. IRCOBI Conf. on the Biomechanics oflmpact, Barcelona, Spain, 1999, pp.2 1 3 -230.d

Jakobsson L„ Norin H.: Suggestions for Evaluation Criteria ofNeck Injury Protection in Rear End Car Impacts, Proc. 1999 Int. IRCOBI Conf. on the Biomechanics of lmpact, Barcelona, Spain, 1 999, pp.271-282.

Svesson M.Y., Bostrom 0„ Davidsson J„ Hansson H.A„ Haland Y„ Lovsund P„ Suneson A„ Saljo A.: Neck Injuries in Car Collisions - A Review Covering A Possible Injury Mechanism and the Development of a New Rear-lmpact Dummy, WAD'99 Compendium/Traffic Safety and Auto Engineering, Vancouver, Canada, 1999, pp.37-60.

Wismans J.S.H.M„ Kroonenberg A.J.: European Research in Whiplash lnjury Prevention, WAD'99 Compendium/Traffic Safety and Auto Engineering, Vancouver, Canada, 1999, pp.61-67.

Kaneoka K„ Ono K„ lnami S„ Hayashi K. : Motion Analysis of Cervical Vertebrae During Simulated Whiplash Loading, WAD'99 Compendium/Traffic Safety and Auto Engineering, Vancouver, Canada, 1999, pp. 1 5 1 - 1 60.

Welcher J.B„ Szabo T.J.: Relationship Between Seat Properties and Human Subject Kinematics in Rear Impart Tests, WAD'99 Compendium/Traffic Safety and Auto Engineering, Vancouver, Canada, 1999, pp.243-274.

Watanabe Y„ Ichikawa H„ Kayama 0„ Ono K„ Kaneoka K„ Inami S.: lnfluence of Seat Characteristics on Occupant Motion in Low Speed Rear Imapcts, WAD'99 Compendium/Traffic Safety and Auto Engineering, Vancouver, Canada, 1999, pp.297-324.

Linder A„ Svensson Y.: A New Mathematical Neck Model for a Low-Velocity Rear-End Impact Dummy: Evaluation of Components Influencing Head Kinematics, WAD'99 Compendium/Traffic Safety and Auto Engineering, Vancouver, Canada, 1999, pp.392-409.

Bostrom 0„ Fredriksson R„ Haland Y„ Jakobsson L„ Krafft M„ Lovsund P„ Muser M.H„ Svensson M.Y.: Comparison of Car Seats in Low Speed Rear-End Impacts Using the BioRID Dummy and the New Neck Injury Criterion (NIC), WAD'99 Compendium/Traffic Safety and Auto Engineering, Vancouver, Canada, 1999, pp.437-450

Jakobsson L„ Lundell B„ Norin H„ Hellman 1.1.: WHIP - Volvo's Whiplash Protection Study,

390 IRCOBI Conference - Montpellier (France), September 2000

WAD'99 Compendium/Traffic Safety and Auto Engineering, Vancouver, Canada, 1999, pp.52 1 -538.

Eichberger A„ Steffan H„ Geigl B„ Svensson M„ Bostrom 0„ Leinzinger P.E„ Darok M.: Evaluation of the Applicability ofthe Neck Injury Criterion (NIC) in Rear End Impacts on the Basis of Human Subject, Proc. 1998 Int. IRCOBI Conf„ Goteborg, , 1998, pp.32 1 -333.

Bostrom 0„ Haland Y„ Fredriksson R.: A Sied Test Procedure Proposal to Evaluate the Risk ofNeck Injury in Low Speed Rear Impacts Using a New Neck Injury Criterion (NIC), l 61h ESV Conf„ Windsor, Canada, 1998, Paper No. 98-S7-0-07.

Davidsson J„ Svensson M.Y„ Flogard A„ Haland Y„ Jakobsson L„ Linder A„ Lovsund P„ Wiklund K.: BioRID I - A New Biofidelic Rear Impact Dummy, Proc. 1998 Int. IRCOBI Conf„ Goteborg, , 1998, pp.377-390.

Davidsson J„ Deutscher C„ Hell W„ Linder A„ Lovsund P„ Svensson M.Y.: Human Volunteer Kinematics in Rear-End Sied Collisions, Proc. 1998 Int. IRCOBI Conf„ Goteborg, , 1 998, pp.289-30 1 .

Shen W„ Wiklund K„ Frid S„ Swamy B„ Nilson G„ Humer M.: Pressure and Load Patterns on Seat Interface: A Comparison Between Human Subjects and Crash Test Dummies, Proc. 1 998 Int. IRCOBI Conf„ Goteborg, , 1998, pp.453-464.

Wiklund K„ Larsson H.: Saab Active Head Restraint (SAHR)- Seat Design to Reduce the Risk of Neck Injuries in Rear Impacts, SAE, 1998, Paper No. 980297.

Lundell B„ Jakobsson L„ Alfredsson B„ Jemstrom C„ Hellman I.I. : Guidelines for and the Design of a Car Seat Concept for Improved Protection Aginst Neck Injuries in Rear End Car Impacts, SAE, 1998, Paper No. 980301 .

Sekizuka M. : Seat Designs for Whiplash Injury Lessening, 1 6111 ESV Conf„ Windsor, Canada, 1 998, Paper No. 98-S7-0-06.

Prasad P„ Kirn A„ Weerappuli D.P.V, Roberts V„ Schneider D.: Relationships Between Passenger Car Seat Back Strength and Occupant Injury Severity in Rear End Collisions: Field and Laboratory Studies, Proc. 4 1st STAPP Car Crash Conf„ Warrendale, PA, USA, 1997, Paper No.973343, pp.41 7-449.

Prasad P„ Kirn A„ Weerappuli D.P.V.: Biofidelity of Anthropomorphic Test Devices for Rear Impact, Proc. 4 1 st STAPP Car Crash Conf„ Warrendale, PA, USA, 1997, Paper No.973342, pp.387-4 1 5 .

Ono K., Kaneoka K„ Wittek A „ Kajzer J.: Cervical Injury Mechanism Based on the Analysis of Human Cervical Vertebral Motion and Head-Neck-Torso Kinematics During Low Speed Rear Impacts, Proc. 4 1 st STAPP Car Crash Conf„ Warrendale, PA, USA, 1997, Paper No.973340, pp.339-356.

Bostrom 0„ Krafft M„ Aldman B„ Eichberger A„ Fredriksson R„ Haland Y„ Lovsund P„ Sterffan H„ Svensson M„ Tingvall C . : Protection ofNeck Injuries in Rear Imapcts Based on Accident Data Simulations, Proc. 1 997 Int. IRCOBI Conf„ Hannover, 1997, pp.251-264.

Thunnissen J.G.M„ Ratingen M.R„ Beusenberg M.C„ Janssen E.G: A dummy Neck for Low Severity Rear Impacts, l 51h ESV Conf„ 1996 Paper No. 96-S 1 0-0-12 .

IRCOBI Conference - Montpellier (France), September 2000 391