1 Welcome to the Camfil Farr Training Academy 1 © C A M F I L F A R R 2 2 - 0 6 - 0 6 By the end of this webinar you will have an update on the new EN779:2012 standard and the opportunity to have clean Indoor Air Quality and energy efficiency with Low Energy Air Filters
Transcript
Page 1: An update on the EN779 2011 Standard

1

Welcome to the Camfil Farr Training Academy

1

© CAM

FIL

FARR

23-

04-0

8

By the end of this webinar you will have an update on the new EN779:2012 standard and the opportunity to have clean Indoor Air Quality and energy efficiency with Low Energy Air Filters

Page 2: An update on the EN779 2011 Standard

EN779:2012 will be arriving

Peter Dyment 07-02-2012

Page 3: An update on the EN779 2011 Standard

WHEN?

The latest indications are the standard will be due for publication later this year. The situation will be updated over the next few months.

We are all trusting that a decision to proceed will be forthcoming so that our industry can make progress and plan for the future.

3

© CAM

FIL

FARR

23-

04-0

8

Page 4: An update on the EN779 2011 Standard

EN779 as a filter test standard has been with us since 1993and was updated in 2002.What is EN779:2012 about and why is it important?

It is the updated European Standard that gives a laboratory test and class to benchmark HVAC air filter particulate efficiency.

It uses a test aerosol of 0.4 micron and ASHRAE dust to load (not test) the filter and increase air filter resistance in stages.

4

© CAM

FIL

FARR

23-

04-0

8

Page 5: An update on the EN779 2011 Standard

5

© CAM

FIL

FARR

23-

04-0

8

EN779:2002 Test Rig

The EN779:2002 test is usually performed by an independent test house on air filters up to F9 classification and a test report is issued. What is new in the 2012 update?

Page 6: An update on the EN779 2011 Standard

EN779 was revised in 2002 because of the problem regarding the inconsistent particulate life performance of synthetic media filters.

6

© CAM

FIL

FARR

23-

04-0

8

SINTEF test results Norway (1995) show real lifetime performance losses

Page 7: An update on the EN779 2011 Standard

Synthetic F7 Class filters have been marketed for many years but some a have a working particulate efficiency dropping as low as 10%.

EN13779 advises that F7 is the minimum filter class required for cleaning air and thereby making it safe to inhale. Clearly this standard assumes a consistent F7 performance.

7

© CAM

FIL

FARR

23-

04-0

8

Page 8: An update on the EN779 2011 Standard

8

© CAM

FIL

FARR

23-

04-0

8

EN779:2012 has set the minimum particulate efficiency (ME) of 35% on an F7 grade filter. This will exclude inferior synthetic media HVAC filters.

Min Effy. 35%

Page 9: An update on the EN779 2011 Standard

9

© CAM

FIL

FARR

23-

04-0

8

Table 1— Classification of air filters1)

Group Class Final test pressure

drop

Average arrestance (Am) of synthetic dust

Average efficiency (Em)

of 0,4 µm particles

Minimum Efficiency2)

of 0,4 µm particles Pa % % %

Coarse G1 250 50 Am 65 - -

G2 250 65 Am 80 - -

G3 250 80 Am 90 - -

G4 250 90 Am - -

Medium M5 450 - 40 Em 60 -

M6 450 - 60 Em 80 -

Fine F7 450 - 80 Em 90 35

F8 450 - 90 Em 95 55

F9 450 - 95 Em 70

NOTE 1) The characteristics of atmospheric dust vary widely in comparison with those of the synthetic loading dust used in the tests. Because of this the test results do not provide a basis for predicting either operational performance or life. Loss of media charge or shedding of particles or fibres can also adversely affect efficiency. 2) Minimum efficiency is the lowest efficiency among the initial efficiency, discharged efficiency and the lowest efficiency throughout the loading procedure of the test.

Test standard for coarse and fine air filters

Page 10: An update on the EN779 2011 Standard

10

© CAM

FIL

FARR

23-

04-0

8

Indoor Air Quality approach 2012Particulate Efficiency

ME (Minimum Efficiency) - F7 > 35% - F8 > 55% - F9 > 70%

Average efficiency – as before with caution - nothing to change

Page 11: An update on the EN779 2011 Standard

11

© CAM

FIL

FARR

23-

04-0

8

Indoor Air Quality approach 2012

Keep the IAQ level high! Risk of decreasing efficiency from competitors!

Page 12: An update on the EN779 2011 Standard

12

© CAM

FIL

FARR

23-

04-0

8

IAQ approach for 2012

When the outdoor air quality has been categorized, EN13779:2007 clearly specifies the filter class that is required to achieve preferred indoor air quality:

Recommendations in EN13779: 2007

Page 13: An update on the EN779 2011 Standard

13

© CAM

FIL

FARR

23-

04-0

8

Indoor Air improvement during 50 years

2011 filters for good IAQ

Particulate

1961 filters for good IAQ

Page 14: An update on the EN779 2011 Standard

14

© CAM

FIL

FARR

23-

04-0

8

Indoor Air improvement during 50 years

2011 filters for good IAQ

Particulate

1961

G4 – M6

F7

Protecting equipment

IAQ / healthF9

Page 15: An update on the EN779 2011 Standard

15

© CAM

FIL

FARR

23-

04-0

8

Indoor Air improvement during 50 years

2011

Particulate

2012

1960 G4 – M6

F7 – F9

Protecting equipment

IAQ health

EN779:2012

Page 16: An update on the EN779 2011 Standard

16

© CAM

FIL

FARR

23-

04-0

8

Indoor Air improvement during 50 years

2011

Particulate

2012

1961

G4 – F6F7 – F9

Protecting equipment

IAQ health

Risk ?Possibility!

Page 17: An update on the EN779 2011 Standard

17

© CAM

FIL

FARR

23-

04-0

8

Why is there a risk during 2012 ?• Glass fibre media F7 >60% efficiency – optimum

• The new EN779:2012 ME = 35% for F7 (Minimum Efficiency)

• Could lead to over 40% less clean air

Page 18: An update on the EN779 2011 Standard

18

© CAM

FIL

FARR

23-

04-0

8

Eurovent Energy Efficiency Rating Programme

Based on…… - EN779:2012

ME - F7 > 35% - F8 > 55% - F9 > 70%

Page 19: An update on the EN779 2011 Standard

19

© CAM

FIL

FARR

23-

04-0

8

• ME - F7 50 > 35% - F8 70 > 55% - F9 80 > 70%

dP lower

Energy rating higher

Eurovent Energy Efficiency Rating Programme

Page 20: An update on the EN779 2011 Standard

20

© CAM

FIL

FARR

23-

04-0

8

Why a is there a risk in 2012 ?

• Traditional glass fibre media F7 > 60% minimum efficiency – in built up environment• Synthetic F7 charged media – ME = 16-20%

• Synthetic media has to improve to reach minimum 35% ME (minimum efficiency) – with increased pressure drop

• New glass media >45% efficiency – lower pressure drop

Page 21: An update on the EN779 2011 Standard

21

Check the Indoor Air Quality Factor (IAQ factor)

21

The IAQ factor is found by dividing the LCC by the ME. It tells you have much filter performance you are getting for your money.

EG. M7 F7 bag = 24.7 IAQG4 S-Flo-F7 bag = 154.6 IAQ

IAQ Factor is 6.25 X

per % Minimum Efficiency (ME)

Page 22: An update on the EN779 2011 Standard

22

© CAM

FIL

FARR

23-

04-0

8

HVAC Air Filtration Hi-Flo F7

Synthetic Competitor F7 S-Flo F7

All medias shown at the same magnification

Synthetic medias rely on electrostatic charge for good particulate efficiency

Page 23: An update on the EN779 2011 Standard

23

© CAM

FIL

FARR

23-

04-0

8

What is the 2012 HVAC product opportunity?• Synthetic media filters will have to improve to reach 35% minimum

particulate efficiency (ME) – meaning an increased pressure drop

• Reduce pressure drop with LEAF – keep minimum efficiency high (ME) usually about 55% to 60% for F7.

• Never compromise on filter particulate efficiency !

• Save energy – better LCC – Eurovent Energy Classification Programme

• That is an improvement opportunity!

Page 24: An update on the EN779 2011 Standard

24

THANK YOU for attending this webinar session

ANY QUESTIONS?Please do not hesitate to contact Camfil Farr for any additional information or to

arrange a visit.For more information about clean air solutions, improving air quality, low energy

air filters, CRC (Carbon Reduction Commitment), AHUs (Air Handling Units) and the EPBD, visit

www.keepthecityout.co.ukwww.lowenergyairfilter.co.uk

blog and subscribe to the RSS Feed


Recommended