RIVER OF LIFE : IMPLEMENTATION OF INTERCEPTOR Anita Ainan Department of Irrigation and Drainage Malaysia
Transcript
Page 1: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

RIVER OF LIFE : IMPLEMENTATION OF INTERCEPTOR Anita Ainan

Department of Irrigation and Drainage Malaysia

Page 2: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

CONTENTS

• INTRODUCTION TO RIVER OF LIFE

• RIVER OF LIFE COMPONENTS

• OBJECTIVES OF INTERCEPTOR

• BASIC CONCEPTS OF INTERCEPTOR SYSTEMS

• INTERCEPTOR PROJECT AT PRECINTS 7

• CONCLUSION

Page 3: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

WHAT IS “RIVER OF LIFE”?

Page 4: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

River of Life

River Cleaning River Beautification Land Development

• Cleaning and beautification works will spur economic

investments into the areas immediately surrounding the river corridor

• Potential government land will be identified and tendered out to private developers through competitive bidding

Transforming Klang & Gombak Rivers into a vibrant and liveable

waterfront with high economic value

• Masterplanning and beautification works will be carried out along a 10.7km stretch along the Klang and Gombak river corridor

• Significant landmarks in the area include DataranMerdeka, BangunanSultan Abdul Samad and Masjid Jamek

• Clean and improve the 110km stretch river

tributaries along the Klang River basin from current Class III-V to Class IIB by 2020

• Covers the municipal areas of: -Selayang (MPS)-Ampang Jaya (MPAJ) -Kuala Lumpur (DBKL)

2011 2020

Page 5: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

RIVER OF LIFE: RIVER CLEANING TRANSFORMING THE KLANG RIVER REQUIRES AN INTEGRATED APPROACH THAT STOPS POLLUTION AT THE SOURCE

Class III & IV• unsafe for body contact

Class IIB• recreational use with body

contact

Aspiration

Key Initiative

Description Lead Agency

1Upgrading existing sewerage facilities is the most impactful and important initiative to reduce Klang river pollution

JPP

2Existing regional sewage treatment plants must be expanded to cater for future growth

JPP

3Wastewater treatment plants need to be installed at 5 wet markets to decrease rubbish and pollutants

DBKL

4Install additional gross pollutant traps will improve the river aesthetics and water quality

JPS Selangor / DBKL

5Utilise retention ponds to remove pollutants1 from sewage and sullage

JPS WPKL

6Relocation of squatters will significantly reduce sewage, sullage, and rubbish in the Klang river

MB Seloffice/MPAJ

7Implement the Drainage and Stormwater Management Master Plan to upgrade drainage systems

BPB JPS

8Systematic hydrological study and rehabilitation of the river are needed for flow control

BPLS JPS

9Promote, enforce, and manage river cleanliness and health –erosion from urban development

BSMA JPS

10Promote, enforce, and manage river cleanliness and health –restaurants, workshops, and other commercial outlets

JKT

11Promote, enforce, and manage river cleanliness and health –industries that generate wastewater/ effluent

DOE

12Promote, enforce, and manage river cleanliness – general rubbish disposal

JPS /JPSPN

13 Interceptor System DBKL/JPS

Page 6: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

01 PUAH POND

02 GPT

03HYDROSEEDIN

G

04

FLOOD MITIGATION

SYSTEM06

07RWTP

(Sg.Kemensah)

08

09 RWTP (Sg.Sering)

River Cleaning Structures in

River of Life Catchment Area

10WWTP (Pasar Ayer

Panas)

FLOATING

WETLAND

05SUBMERGED SOLAR

AERATOR

Site No.1

– Puah Pond

Site No.2

– RWTP Sg.Sering

Site No.3

– WWTP Pasar Air Panas

11 Bunus STP

Site No.4

– Bunus STP

FLOOD MITIGATION

SYSTEM

Page 7: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

Upgrading Sewerage Treatment

Plant

Waste Water

Treatment Plant

Gross Pollutant

TrapPuah Pond

Floating Wetland

Gross Pollutant Trap

River Water Treatment

Plant

Mechanically Stabilized Earth

Wall

KI 1 & KI 2 : JPP KI 3 & KI 4b :

DBKL

KI 4a : JPS KI 5 : JPS

KI 7 : JPS

RIVER OF LIFE: RIVER CLEANING

STRUCTURE MEASURE FOR RIVER CLEANING

KI 5 : JPS

Page 8: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

Grease Trap

Interceptor Interceptor

River of Life: Structure Measure for River Cleaning

KI 13 : JPSKI 10 : JKT

Page 9: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

MASJID JAMEK – CONFLUENCE of KLANG AND GOMBAK RIVER

Page 10: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

Steel Tilting Gate ( Hydraulic Type )

Technical Data :

Product = Hydraulic Collapsible Gate

Material = Stainless Steel

Operation Method = Hydraulic Cylinder

Maximum Recommended Height = 10m

Warranty Period = 5 years

Life Span = Approx. 40-50 years depends on

weather,

site conditions and usage’s frequency

Hydraulic Tilting Gate

Page 11: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

To implement an interceptor pipeline and waste

water treatment system to improve the river water

quality for 10.7 km of Sg. Gombak & Sg. Klang

within RoL area so as to create a clean &

aesthetically pleasing river front for the city of

Kuala Lumpur.

Page 12: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek
Page 13: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

Project goal: To improve water quality by intercepting and

treating dirty drain water:

To intercept dry weather and first flush flows from drains that

discharge to Sg. Klang and Sg. Gombak

First flush flow is defined as 5% of 1 month ARI storm event

Treat the intercepted flow to Class IIB water quality and return to the

river

Page 14: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

14

Sullage water discharging in to the

drain without treatment

SOURCE OF POLLUTION

Connections from

Kitchens Overflow Illegal

Sewer Connection

Leaking Sewer

Pipe

Page 15: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

• Divert low flow & first flush to interceptor pipeline while

excess high flows will bypass at Combined Stormwater

Overflows (CSO) & discharge to rivers.

• Install pipelines along both banks of rivers to collect polluted

discharges (sullage) from drainage outlets & convey to

treatment plants (RWTP).

• Intercepted discharges after being treated at River Water

Treatment Plants (RWTP) will be released back to the river.

• To have CSO, pump stations and most part of treatment plants

below ground as far as possible.

Page 16: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

Existing Drainage

Interceptor will channel

sullage/trade waste first

to treatment plant

Sullage/trade waste is

then treated at river water

treatment plants before

discharge

During heavy rainfall,

excess stormwater will

directly discharge into

river

Interceptor System

A

B

C

Page 17: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

Manhole

Combined

Stormwater

Overflow

(CSO)

GPT

River

To

RWTP/WWTP

INTERCEPTOR SYSTEM OPERATION

MH

Page 18: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

RIVER

DURING LOW FLOW TO SWTP

CSO

GPT

• CSO-Divert the Polluted Low flows from the

drainage outlets to the interceptor pipe lines

• Able to pass a discharge up to the capacity of

the existing drainage during high flows and divert

to the interceptor pipelines a flow equal to 5% of

the 1 month ARI storm discharges

Page 19: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

DURING HIGH FLOW

RIVER

TO SWTP

CSO

GPT

CSO-two chamber in-line structure located slightly upstream of

drainage outlet. The main chamber receives the inflow from

upstream and the low weir located on the chamber floor will divert

the low flow and initial storm discharge to the adjacent chamber GPT.

Non-return check valve installed at the downstream end of the CSO

to minimized back flow of water

Page 20: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

Pipeline in bank (Pipe-jacking)Pipeline in bank (cut & cover)

Page 21: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

DUKE

Interceptor Pipe

Treatment Plant

Page 22: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

Interceptor Pipe

Treatment Plant

Page 23: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

Federal Highway

Interceptor Pipe

Treatment Plant

Page 24: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

INTERCEPTOR PRECINT 7 : PHASE 1

Page 25: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

PROJECT LOCATION

Page 26: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

• 4 Wastewater Treatment Plants (WWTP) treated to Class IIB effluent

quality:

Plant 1 - 4.7 m3 / min

Plant 2 - 3.7 m3 / min

Plant 3 - 2.1 m3 / min

Plant 4 - 1.5 m3 / min

• 24 Combined Stormwater Overflows (CSOs):

8 pumped CSOs complete with gross pollution trap/screen

16 non-pumped CSOs

• 2 fully underground Pumping Stations of the following capacities:

Pump Station PS2 - 1.82 cu.m / min

Pump Station PS3 – 10.8 cu.m / min

• Approximately 2.25 km of pipelines (gravity and pumped)

SCOPE OF WORKS

Page 27: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

ALTERNATIVE DESIGN –

DECENTRALISED TREATMENT

L1: Treated at siteL2: Treated at siteL3: Intercept Only But Alternative Alignment

Plant 1

Plant Not to Scale

Transfer Line C to P8 for Treatment

Precinct 7

CSO

Plant 2

Plant 3Plant 4

MerdekaSquare

Central Market

Masjid Jamek

POS & Daya Bumi

HSBC

Page 28: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

ROL P7 – INTERCEPTOR WORKS

L1: Treated at site

L2: Treated at site

Plant 1

Plant Not to Scale

Transfer Line C to P8 for Treatment

Precinct 7

CSO

Plant 2

Plant 3Plant 4

MerdekaSquare

Central Market

Masjid Jamek

POS & Daya Bumi

HSBC

Page 29: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

TREATMENT PLANT NO 1

PROPOSED

TREATMENT PLANT

NO 1

DATARAN MERDEKA

Page 30: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

TREATMENT PLANT NO 2

PROPOSED

TREATMENT PLANT

NO 2

MASJID

JAMIK

Page 31: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

TREATMENT PLANT NO 3

PROPOSED

TREATMENT PLANT

NO 3

Page 32: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

PROPOSED

TREATMENT PLANT

NO 3SULTAN ABDUL

SAMAD BUILDING

LOKE YEW BUILDING

Page 33: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

TREATMENT PLANT NO 4

PROPOSED TREATMENT

PLANT NO 4

DAYA BUMI

LRT PASAR SENI

Page 34: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

PLANT 1 TYPICAL CROSS SECTION

WWTP located in the public open space that is being developed and improved in the

beautification works projects. In order to prevent any clash or adversed impact on

beautification projects , WWTP are located below ground with minimal impact above ground

features.

Page 35: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

PROPOSED WWTP

The proposed plant are Submerged Biofilter capable consists of solid phase for microbilogical

growth, liquid phase in which the solids are submerged and gas phase created by the input of air

to the biofilter. The plant shall be able to provide self regulating natural conducive environment for

the growth of aerobic micro-organism that are able to remove BOD, ammonical nitrogen and

suspended solid.

Page 36: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

PRIMARY TREATMENT – GPT / SCREENCaptures:

>95% of gross pollutants >3mm

>50% of gross pollutants >1mm

>70% of O&G with additional

absorbents

Page 37: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

SECONDARY TREATMENT -

BIOREACTOR

Page 38: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

Biofilter Media:

Media with excellent microorganism attachment capabilities, including high initial attachment rate (>25 mg MLSS/m2/hr)

Long endurance (lifespan not less than 20 years)

Media material contains mineralised plastic: zeolite (40%) and polyethylene (60%)

Hydrophilic nature with contact angle less than 90 degrees

High surface roughness of media material

Specific surface area of 500 m2/m3

Liquid fraction of 60%

Page 39: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

TERTIARY TREATMENT - CARTRIDGE

FILTER

– Removes particles up to 93 micron– Removes up to 92% TSS (20-2000 micron)– Each cartridge treats up to 16L/s

Page 40: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

DESIGN FLOWS

Parameter Plant 1 Plant 2 Plant 3 Plant 4

Peak pumped flow from balance tank 25.9 L/s 20.7 L/s 11.7 L/s 24.7 L/s

Reactor volume (at min. water level) 145.0 m3 497.1 m3 183.6 m3 47.9 m3

Liquid volume (at min. water level) 95.7 m3 328.1 m3 121.2 m3 32.2 m3

HRT at peak flow (on reactor volume) 1.6 hr 6.7 hr 4.4 hr 0.54 hr

Liquid depth (at min. water level) 4.4 m 4.0 m 4.0 m 3.55 m

Each WWTP should be able to accommodate both the dry weather flow which is

anticipated to occur for the vast majority of the time, and wet weather which is equivalent

to 5 % of first flush of 1 month ARI storm event. The maximum design inflow and the plant

required capacity shall be 1.15 times the wet weather flow capacity.

Page 41: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

INFLUENT WATER QUALITY

Dry weather

Wet weather (First flush)

Parameter Plant 1* (P7 Only)

Plant 1 (Design)

Plant 2 Plant 3 Plant 4

COD (mg/L) 44 - 71 43 - 56 123 - 176 142 – 160

15 - 31

BOD (mg/L) 8.6 - 13.6 8.2 - 10.7 23 - 34 28 - 31 2.8 - 5.3 TSS (mg/L) 15 - 38 16 – 28 17 - 35 46 - 50 8 - 12 NH3-N (mg/L) 0.5 - 1.3 1.0 - 1.4 1.7 - 3.5 4.3 - 4.9 1.5 - 3.4 sCOD (mg/L) 23 - 36 25 – 31 35 - 44 29 - 30 10 - 23

Parameter Plant 1* (P7 Only)

Plant 1 (Design)

Plant 2 Plant 3 Plant 4

COD (mg/L) 50 - 4 43 - 3 201 - 7 146 - 10 34 - 4 BOD (mg/L) 9.3 - 0.7 8.2 - 0.5 38 - 1 29 – 2 5.9 - 0.7 TSS (mg/L) 25 - 1 18 - 1 22 - 1 47 – 3 13 - 2 NH3-N (mg/L) 0.8 - 0.0 1.0 - 0.1 2.4 - 0.1 4.4 - 0.3 2.0 - 0.3 sCOD (mg/L) 27 - 2 22 - 2 46 - 2 30 – 2 25 - 2

Water quality was collected during dry weather for the drains with outlets that discharges to Sungai

Klang and Sungai Gombak. Dry weather quality data represent the flow weighted dry weather influent

for each WWTP

Page 42: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

CONTROL AND OPERATION

Each plant operates automatically under PLC control connected to a SCADA system

fully automatic control and operation of the process and all equipment:

Level switches for pump control with additional low flow/level switch to prevent dry run.

High water level switch to indicate overflow of balance tank and cuts-off inflow from pumped CSOs

High level alarm switch for sump in equipment room

Visual pressure gauges on aeration blowers: incoming air gauge to check for air filter clogging, and discharge pressure gauge

Variable speed drive to control aeration blower speed based on DO reading

Page 43: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

TARGET CLASS IIB EFFLUENT QUALITY

Parameter Target Value

BOD 3 mg/L

COD 25 mg/L

NH3-N 0.3 mg/L

SS 50 mg/L

Page 44: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

PHOTOS DURING CONSTRUCTION

Page 45: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

45

CSO For Plant 1CONSTRUCTIONS OF CSO AT PLANT 1

Page 46: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

PLANT 1

BIOREACTOR AND CLARIFIER ROOM

Page 47: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

47

BIOREACTOR AND CLARIFIER ROOMBIOREACTOR AND CLARIFIER ROOM

Page 48: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

PLANT 1- BIOREACTOR AND CLARIFIER

Installation of cartridge filter Loading the media into the plant

Page 49: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

PLANT 1

Installation of diffuser

Installation air blower

Page 50: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

PLANT 2

Page 51: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

PLANT 2 –SLUDGE HOLDING TANK, BIOREACTOR, CLARIFIER &

BALANCE TANK

Installation of water tight cover

Installation of pump in balance tank

Installation of water tight cover

Page 52: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

PLANT 2 –SLUDGE HOLDING TANK, BIOREACTOR, CLARIFIER &

BALANCE TANK

Page 53: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

HSBC CSO & PIPELINES FOR PLANT 2 2PIPE LINE CONSTRUCTIONS

Page 54: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek
Page 55: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

55

Plant 3PLANT 3

Page 56: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

PLANT SHEET PILING IN PROGRESS

Page 57: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

UTILITIES RELOCATION AT PLANT 3

Page 58: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

PLANT 3

Pipeline installation

Installation of water tight cover

Page 59: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

PLANT 3

Page 60: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

Combine Sewer Overflow (CSO) Pipeline

Formwork CSO 4-1-1 Concreng CSO 2-1-1

Page 61: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

Combine Sewer Overflow (CSO) Pipeline

Pump Installation CSO 2-3-3

Pump Installation CSO 1-1-2

Page 62: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

EQUIPMENT ROOM

Page 63: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek
Page 64: Anita Ainan Department of Irrigation and Drainage Malaysiamucp-mfit.org/wp-content/uploads/6-Implementation-Interceptor-AZIAN.pdf · Merdeka, Bangunan Sultan Abdul Samadand MasjidJamek

CONCLUSION

• Interceptor is one of the initiative implemented by government to

improve of the water quality.

• Operation and Maintenance is a key success of the interceptor

project.

• Precint 7 Interceptor Project now is under testing and

commissioning. Water Quality Class IIB from the treatment facility

expected can be achieve after 3 month operation.