6
FLICKER UGR 16 Visual comfort Modular Design 126/116 lm/W APOLLO . PANEL LIGHT APOLLO . PANEL LIGHT NEW PRODUCTS LED LIGHTING
Transcript
Page 1: Apollo panel light-B-1 - Kinglumi 16 126lm per watt Apollo pan… · APOLLO . PANEL LIGHT • Modular Design: 1 pair of light module with different frames fit all European ceiling

FLICKER

UGR16Visual

comfortModularDesign

126/116lm/W

APOLLO . PANEL LIGHTAPOLLO . PANEL LIGHTNEW PRODUCTS

LED LIGHTING

Page 2: Apollo panel light-B-1 - Kinglumi 16 126lm per watt Apollo pan… · APOLLO . PANEL LIGHT • Modular Design: 1 pair of light module with different frames fit all European ceiling

APOLLO . PANEL LIGHT

• Modular Design: 1 pair of light module with different frames fit all European ceiling grid.• Less inventory and risk, faster time to projects, allow variety of ceiling grid size• Glare free: UGR<16, luminance limits @65°<1000cd/m , EN 12464-1: 2011 compliant• High efficacy: Up to 126lm/W(Pro), or 100lm/W(Standard)• More useful light: over 90% useful lumen in cone 90°(zonal lumen)• Dimming: Non-diming, DALI and 1-10V dimming(only for Pro.)• Class II,SELV, High Power Factor over 0.95• Non-flicker design(only for Pro).• Aluminum passive cooling, TcLED<61°C(Ta=25°C)• Installtion: Recessed/Pendant mounted• Direct replacement for T8- 3x18W/4X18W; T5- 3x14W/4X14W• Up to 65% energy saving, 3 times longer lifespan compared to fluorescent lamps.

Features:

PARAMETERS

Power(W):Heat sink:Lifespan(hrs):CRI:Beam Angle:

28(Pro); 30(Standard)Aluminum50,0008285°x70°

3600(Pro); 3400(Standard)220-240126(Pro); 116(Standard)2x63pcs Epistar SMD 2835-20-40°C

Lumen(lm):Input Voltage(VAC):Efficacy(lm/W):LED ChipsWorking Temp:

Cut-out: To fit all Europe ceiling T grid:600*600 / 625*625、300*1200、600*1200

UGR

16 5years warranty

2

Page 3: Apollo panel light-B-1 - Kinglumi 16 126lm per watt Apollo pan… · APOLLO . PANEL LIGHT • Modular Design: 1 pair of light module with different frames fit all European ceiling

Recessed

Pendent

38

1195

29549

489

620

620

595

595

Installation Dimention(mm)

Page 4: Apollo panel light-B-1 - Kinglumi 16 126lm per watt Apollo pan… · APOLLO . PANEL LIGHT • Modular Design: 1 pair of light module with different frames fit all European ceiling

APOLLO . PANEL LIGHT

LIGHT DISTRIBUTION

Kinglumi Apollo Panel light Fluorescent Modular Flat LED Panel

Philips TBS262 4xTL5-14W 840 HFS M6 40W 600x600 NW LED panel light Eco2K&L Apollo Panel 4000K

105

90

75

60

45

30 3015 150

105300

300

600

900

1200

1500

90

75

60

45

75

60

45

105

90

75

60

45

30 3015 150

105

320

480

640

90

105

90

75

60

45

30 3015 150

105400

400

800

1200

1600

2000

90

75

60

45

Symmetrical light distribution with a batwing.

1.0m 211.00cm2224.8 , 960.3 lx

2.0m 422.00cm556.2 , 240.1 lx

3.0m 632.99cm247.2 , 106.7 lx

5.0m 1054.99cm89.0 , 38.4 lx

Max , Ave Beam angle of C120 plane 84x67

Lux distance CurveAt application: (4H,8H), Reflection (70%,50%,20%)Standard Version: UGR≤14 Pro Version: UGR≤15

UGR table of Pro version 595*595 3600lm

UGR Table

Illumination assessment according UGRRf of Ceiling 70 70 50 50 30 70 70 50 50 30Rf of Wall 50 30 50 30 30 50 30 50 30 30Rf of Floor 20 20 20 20 20 20 20 20 20 20Room dimensions Viewed crosswise Viewed endwiseX Y2H 2H

3H4H6H8H12H

4H 2H3H4H6H8H12H

8H 4H6H8H12H

12H 4H6H8H

Variation with the observer position at spacings:S = 1.0HS = 1.5HS = 2.0H

Standard tables:Uncorrected UGR

10.7310.5510.4610.3810.3110.2410.5110.2910.2310.0910.039.9810.039.889.869.809.989.869.80

11.8511.5311.3711.2111.1010.9911.4111.0410.8710.6610.5610.4710.5610.3110.2310.1010.4710.2310.10

11.1010.9410.8610.8010.7310.6710.9110.7210.6610.5610.5210.4710.5210.3810.3910.3410.4710.3910.34

12.1611.8711.7211.5811.4811.3811.7611.4311.2911.1111.0110.9211.0110.7910.7510.6110.9210.7510.61

12.4712.2212.0911.9811.8911.8012.1311.8511.7411.5611.4911.4311.4911.3011.2511.1311.4311.2511.13

14.9414.7614.6614.5814.5114.4414.6614.4514.3814.2514.1914.1414.1914.0314.0213.9614.1414.0213.96

16.0515.7415.5715.4115.3015.1915.5715.1915.0214.8114.7114.6214.7114.4714.3914.2614.6214.3914.26

15.3015.1415.0615.0014.9314.8715.0614.8714.8214.7214.6714.6314.6714.5414.5514.5014.6314.5514.50

16.3616.0715.9215.7915.6915.5915.9215.5915.4515.2615.1715.0715.1714.9514.9114.7715.0714.9114.77

16.6716.4216.2916.1816.0916.0016.2916.0015.9015.7215.6415.5915.6415.4615.4015.2915.5915.4015.29

2.2/-6.7 4.6/-25.54.1/-21.5 6.4/-29.06.1/-28.6 8.4/-29.5BK0 BK0-4.0 -8.2

UGR calculation is based on CIE Publ. 117 ,S/H = 0.25

Page 5: Apollo panel light-B-1 - Kinglumi 16 126lm per watt Apollo pan… · APOLLO . PANEL LIGHT • Modular Design: 1 pair of light module with different frames fit all European ceiling

APOLLO . PANEL LIGHT

LUMINANCE LIMITS

Luminance Limitting Curveγ(°)

85

75

65

55

456 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3

L(cd/m²)4

-2

-3

-4

-6-8 (a/hs)

a b c d e f g h

C0 C45 C90

According to EN12464-2011 part 4.9.2, Light can lower the contrast of the presentation on a DSE. The Table 1 gives the limits of the average luminaire luminance at elevation angles of 65° and above from the downward vertical, radially around the luminaires, for work stations where display screens which are vertical or inclined up to 15° tilt angle are used.

Table 1 — Average luminance limits of luminaires, which can be reflected in flat screens

Screen high state luminance High luminance screen

L> 200 cd·m-2

Medium luminance screen

L ≤ 200 cd·m-2

Case A (positive polarity and normal

requirements concerning colour anddetails of the shown information, as

used in office, education, etc.)

(negative polarity and/or higherrequirements concerning colour anddetails of the shown information, as

used for CAD colour inspection, etc.)

≤3 000 cd·m -2 ≤1 500 cd·m-2

≤1 500 cd·m -2 ≤1 000 cd·m-2

Case B

NOTE Screen high state luminance (see EN ISO 9241-302) describes the maximumluminance of the white part of the screen and this value is available from the manufacturerof the screen.

Glare Table

Glare Quality Service Values Illuminance(lx)

1.15 A 2000 1000 500 <=300

1.5 B 2000 1000 500 <=300

1.85 C 2000 1000 500 <=300

2.2 D 2000 1000 500 <=300

2.55 E 2000 1000 500 <=300

a b c d e f g h

luminance limits @65°<1000cd/m

Page 6: Apollo panel light-B-1 - Kinglumi 16 126lm per watt Apollo pan… · APOLLO . PANEL LIGHT • Modular Design: 1 pair of light module with different frames fit all European ceiling

E-mail: [email protected] Http: www.kinglumi.comFax: 0086-755-29516759 Tel: 0086-755-29516789 33985808Add: Bldg 3,Nangang Third Industrial Zone,Tangtou,Shiyan Town,Bao’anDistrict,Shenzhen City,China 518108

Professional I Unique I ComfortableLED LIGHTING


Recommended