1
ARC Resources Ltd.
ARC Resources Waste Heat Recovery Project
Verification Report
September 10, 2020
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
1
1 Verification Objective and Details
The objective of the verification is to confirm data, controls and processes supporting the emission
reduction or removal calculations as presented in the GHG Report and corresponding GHG Assertion
according to the procedures set out in ISO 14064-3.
Additional objectives include confirming that the GHG Report and corresponding GHG Assertion
conformed to the requirements and principles of ISO 14064-2 and are without material discrepancies.
ISO 14064-2 defines the following terms used in the context of a GHG verification:
GHG Assertion: a declaration or factual and objective statement made by the Responsible
Party.
Project: activity or activities that alter the conditions identified in the baseline scenario which
cause greenhouse gas emission reductions or greenhouse gas removal enhancements.
ISO 14064-2 defines the following parties associated with the verification:
Responsible Party: person or persons responsible for the provision of the greenhouse gas
assertion and supporting GHG information.
The Responsible Party for this verification is ARC Resources Ltd. (ARC Resources).
Intended User: individual or organization identified by those reporting GHG-related information
as being the one who relies on that information to make decisions.
The Intended User for this verification is the CSA CleanProjects® Registry and its users.
Verifier: competent and independent person, or persons, with the responsibility of performing
and reporting on the verification process.
The Verifier for this verification is Brightspot Climate Inc. (Brightspot). The verification team
members are described in Section 1.11 of this report.
1.1 Project Title
ARC Resources Waste Heat Recovery Project.
1.2 Project Start Date
The project start date and crediting start date is January 1, 2020.
1.3 Verification Site Visit (date)
A site visit to ARC Resources Waste Heat Recovery Project facilities was conducted by Rodrigo
Cubedo from August 13, 2020. During the site visit ARC Resources personnel provided an overview of
the facility and answered questions related to the use of waste heat at the facilities, maintenance and
calibration of equipment, and associated data collection procedures. The internal processes for tracking
and monitoring daily operation parameters were demonstrated.
1.4 Expected Lifetime of the Project
The expected lifetime of the project is 15 to 20 years.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
2
1.5 Type of Greenhouse Gas Emission Reduction or Removal Project
The ARC Resources Waste Heat Recovery Project is an aggregated project that uses waste heat
recovery equipment to capture turbine waste heat. This recovered heat replaces natural gas
combustion to heat the process heat medium used in various applications.
1.6 Methodology Appropriateness
The project uses guidance from the Alberta Quantification Protocol for Waste Heat Recovery, Version
2.0 (the “Protocol”) for the selection of greenhouse gas sinks, sources and reservoirs (SSRs) and
quantification of associated GHG emissions.
The application of the Protocol methodology has been confirmed as appropriate for the Project based
on a review of the following:
• The reductions between the baseline scenario selected and project condition present in this
project.
• The fundamental assumptions and criteria for SSR emissions are met by the project.
• Quantification of baseline and project conditions are functionally equivalent, and;
• Quantification is based upon actual measurement and monitoring, where applicable.
1.7 Legal Land Description
The facilities included in the ARC Resources Waste Heat Recovery Project., along with their location,
are provided in Table 1. The latitude and longitude for the location was confirmed by cross-referencing
with the facility LSD.
Table 1. Facilities Included in the ARC Resources Waste Heat Recovery Project.
Facility LSD Latitude Longitude
Dawson III & IV Gas Plant 13-07-080-14W6 55.92524 -120.189902
1.8 Ownership Verification
Based on a review of facility data through Petrinex and the BC Oil & Gas Commission Data Centre, as
well as company annual reports, the owner and operator of the facilities included in the project is the
Responsible Party. ARC Resources is the Responsible Party making the GHG Assertion.
1.9 Reporting, Monitoring, and Verification Details
The GHG reporting period covered by this verification is January 1, 2020 to April 30, 2020.
The asserted total emissions reduction for the reporting period is 8,427 tonnes CO2e.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
3
The Responsible Party has developed a monitoring plan for each of the project parameters, including
the quantification variable used to calculate the emission reduction. The monitoring plan was reviewed
during the verification – see Section 3.5 for the verification results.
This Verification Report will be posted publicly on the GHG CleanProjects® registry along with the GHG
Project and related GHG Report and Assertion September 8, 2020, Version 1 to which it pertains.
1.10 Level of Assurance and Verification Summary
The verification was planned and executed to reach a reasonable level of assurance.
There were no discrepancies detected in the final GHG Assertion.
The Responsible Party’s asserted emission reduction is provided in the following table:
Table 2: GHG Assertions by Vintage Year
GHG Emission Reduction
January 1, 2020 – April 30, 2020: 8,427 tonnes CO2e
Source: GHG Report – ARC Resources Waste Heat Recovery Offset Project, Version 1, September 8, 2020
1.11 Roles and Responsibilities
REPORT VERIFIER
Brightspot Climate Inc.
409 Granville Street, Suite 401
Vancouver, BC V6C 1T2
A Statement of Qualifications for the verification team is included in Section 6. The verification team was
comprised of the following:
Lead Verifier
Aaron Schroeder, P.Eng.
+1 (604) 353-0264
The Lead Verifier was responsible for the oversight of all activities
conducted within the verification, including the development of the
Verification Plan, as well as the execution of the verification procedures.
The Lead Verifier was lead author of the Verification Report and executed
the Verification Statement.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
4
Associate Verifier
Katja Hetmanchuk, Jr. Eng.
+1 (438) 378-3188
Katja Hetmanchuk provided support to the verification team through the
development of the Verification Plan, the carrying out of the verification
procedures and the development of the Verification Report.
Associate Verifier
Rodrigo Cubedo, EIT
+1 (778) 814-1184
Rodrigo Cubedo provided support to the verification team by conducting
the site visits.
Peer Reviewer
Deepika Mahadevan, P.Eng.
+1 (647) 633-8310
The Peer Reviewer conducted an independent peer review of the
verification.
AUTHORIZED PROJECT CONTACT
Zainab Dadashi
Modern West Advisory
Unit 600, 505 2nd street SW
Calgary, AB T2P 1N8
+1 (403) 400-7106
PROJECT PROPONENT
ARC Resources Ltd.
Unit 1200, 308 4 Ave SW
Calgary, AB T2P 0H7
Contact: Kyla Cuthbertson
Environmental Coordinator
+1 (403) 503-8634
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
5
1.12 Accreditation
Brightspot Climate Inc. is an accredited verification body by the Standards
Council of Canada1, accreditation number 07010.
This verification was completed in conformance with the requirements of the
ISO 14064-3, ISO 14065 and ISO 14066 standards.
1 The SCC Accreditation Symbol is an official symbol of the Standards Council of Canada, used under license.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
6
2 Verification Criteria
As per ISO 14064-3, the verification assessed the project document and all supporting information.
The Project was developed using guidance from project uses guidance from the Alberta Quantification
Protocol for Waste Heat Recovery, Version 2.0 (June 2018).
2.1 Scope
Table 3: Verification Scope
Geographic Boundary: Dawson III and IV Gas Plant (see Section 1.7)
Physical Operations: Waste heat recovery from combustion turbines
GHG Sources: • Process heat medium heater
• Fuel Extraction & Processing
Type of GHGs: • Carbon Dioxide (CO2)
• Methane (CH4)
• Nitrous Oxide (N2O)
Reporting Period: January 1, 2020 – April 30, 2020
2.2 Materiality
The quantitative materiality threshold identifies misstated or omitted information that would significantly
misrepresent the GHG Assertion to the intended user. For this project, the quantitative materiality
threshold is equal to 5% of the asserted greenhouse gas emission reduction. Qualitative discrepancies
will also be evaluated and considered against the needs of the intended user.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
7
3 Verification Plan
3.1 Preliminary Review
The verification team conducted a preliminary review of the project and project documentation. The
review was conducted by reviewing the draft GHG Report and interviewing representatives of the
responsible party. Through this review, the verification team confirmed that the team has the necessary
technical skills and competencies to review the nature, scale and complexity of the project.
A preliminary review of the completeness and appropriateness of the GHG Report and GHG Assertion
and data management systems confirmed that the project is ready for verification.
There were no issues raised through the preliminary review that would have precluded the completion
of the verification.
3.2 Verification Risk Assessment
The Verification Risk Assessment was completed during the verification planning stage. Verification risk
is defined as the risk of an incorrect verification conclusion. It can be calculated as the product of the
Project’s inherent risks, the Responsible Party’s control risks and the Verifier’s detection risks. The
verifier cannot affect the inherent risk or the control risk. Therefore, to reduce the overall verification risk
and reach the agreed level of assurance (defined in the verification scope), the verifier must design
verification procedures that reduce the detection risk.
The following table presents the results of the verification risk assessment. Each inherent and control
risk is described along with the risk evaluation (high/medium/low). The risk evaluation considers both
the magnitude of the activity data or inventory component on the overall GHG assertion as well as the
probability that the risk will result in a discrepancy, as assessed by the verifier.
In instances where a substantive approach is applied in the verification procedure (i.e. the procedure
tests the data, rather than the Responsible Party’s controls), the Responsible Party’s control is not
listed, but is denoted “N/A”; however, this does not imply that the Responsible Party does not have a
control in place.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
8
Table 4: Verification Risk Assessment
Activity Data / Inventory
Component
Inherent Risk Control Risk Detection
Risk Design
Description of Verification Procedure
GENERAL APPLICABILITY REQUIREMENTS
Ownership must be clearly
defined
Relevance – Low
The Responsible Party may
not have ownership or be
the operator of the facilities
in the Project.
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test: Confirm ownership of facilities
through the BC Oil & Gas Commission Data
Centre.
ISO 14064-2 REQUIREMENTS
Project information Completeness – Medium
The project information
provided in the GHG report
may not include all
information required by ISO
14064-2.
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test – review all information provided
in the GHG Report, comparing it to observations
made during the site visit and data and
documentation provided by the Responsible
Party. Confirm that all required data is included in
the report and is accurate.
Definition and selection of
Sources, Sinks and
Reservoirs (SSRs)
Completeness – High
SSRs identified and
selected for quantification
may be incomplete or may
not be relevant to the
project.
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test – review the GHG Report and
supporting documentation, comparing the
selection of SSRs described in these documents
to observations made during the site visit.
Evaluate the justifications provided for excluding
SSRs, confirming that a conservative approach
has been applied.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
9
Activity Data / Inventory
Component
Inherent Risk Control Risk Detection
Risk Design
Description of Verification Procedure
Data monitoring for each
quantification parameter
Completeness – High
Plan for monitoring data
may be incomplete,
inappropriate or may not
provide for sufficient
transparency in data.
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test – review the GHG Report and
supporting documentation, comparing the
selection of SSRs described in these documents
to observations made during the site visit.
Evaluate the justifications provided for excluding
SSRs, confirming that a conservative approach
has been applied.
BOUNDARY CONDITIONS
Emission sources Completeness – Low
The Responsible Party may
have not included all
relevant sources in the
quantification
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test: Review provided
documentation for errors, omissions and
abnormalities.
Substantive test: Interview field personnel and
observe facility during site tour to confirm
possible emission sources.
Substantive test: Interview field personnel and
observe facility during site tour to confirm that
waste heat would be dissipated in absence of the
Project (no alternative uses of waste heat).
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
10
Activity Data / Inventory
Component
Inherent Risk Control Risk Detection
Risk Design
Description of Verification Procedure
Reporting period Cut-off – Low
The quantification may
include activity data from
outside the reporting
period.
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test: Confirm data is relevant to the
reporting period defined by reference criteria.
METHODOLOGIES
Emission quantification
methodologies
Consistency – High
The quantification
methodologies may be
inconsistent between the
Responsible Party’s
quantification document
and the calculations.
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test: Confirm methodologies are
consistent with reference criteria.
Emission quantification
relevance
Relevance – High
The selected protocol may
not be applicable to meet
the criteria.
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test: Evaluate functional equivalence,
baseline condition, project condition, boundary
and additionality as described by the Responsible
Party. Confirm that operating conditions are
represented by the information presented in the
GHG Report for these parameters.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
11
Activity Data / Inventory
Component
Inherent Risk Control Risk Detection
Risk Design
Description of Verification Procedure
ACTIVITY DATA
WHR unit operating hours Accuracy – Medium
Operating hours may be
incorrect.
Transcription of values may
not have been transcribed
accurately into calculation
spreadsheet.
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test: Compare operating hours with
process heat medium fluid flowrate data and
identify any anomalies.
Substantive test: Confirm accurate transcription
of values into quantification spreadsheet.
Completeness – Medium
Operating hours may be
incomplete.
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test: Review activity data for
completeness and identify any anomalies.
Process heat medium fluid
inlet temperature, outlet
temperature and flowrate
Accuracy – High
Meters may provide
incorrect values.
Accuracy –
Medium
Responsible Party
uses internal
review.
Low Substantive test: Confirm accurate transcription
of values into quantification spreadsheet and
review engineering estimates for appropriateness.
Controls test: Review meter maintenance
records.
Completeness – High
Meter data may be
incomplete.
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test: Review activity data for
completeness and identify any anomalies.
Substantive test: Observe equipment and
metering locations during site tour.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
12
Activity Data / Inventory
Component
Inherent Risk Control Risk Detection
Risk Design
Description of Verification Procedure
Natural gas composition Accuracy – Medium
The gas composition may
be incorrect.
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test: Confirm the accurate
transcription of the gas analysis data and review
compositions for abnormal concentrations.
Natural gas emission
factors
Accuracy – Medium
Quantification of emissions
may be over- or
underestimated.
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test: Compare emission factors used
in quantification to reference sources.
QUANTIFICATION
Emission quantification Accuracy – High
Emissions or production
quantification may be
inaccurately calculated.
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test: Perform independent
calculations of emissions.
DATA INTEGRITY
Activity data and emission
factor data integrity
Accuracy – Medium
Values may be inaccurately
transcribed between
electronic systems and
calculation sheets.
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test: Use data from original source
for quantification calculations where possible.
Substantive test: Confirm data collection
procedures through observation and inquiry
during the site visit.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
13
Activity Data / Inventory
Component
Inherent Risk Control Risk Detection
Risk Design
Description of Verification Procedure
All inventory emission,
production and reporting
quantities
Accuracy – Medium
Final emission reduction
may not have been
transcribed accurately from
calculation spreadsheets
into the Offset Project
Report.
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test: Confirm accurate transcription
from GHG calculation to final reporting
documents.
Completeness – Medium
Final quantities may be
incompletely transcribed.
N/A – verification is
not relying on
Responsible Party
Controls.
Low Substantive test: Confirm accurate transcription
from GHG calculation to final reporting
documents.
3.3 Sampling Plan
No verification procedures that could apply sampling of the project data were performed.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
14
3.4 GHG Report
The final GHG Report subject to this verification is dated September 8, 2020.
The asserted emission reduction quantity is shown in Section 1.9 of this report.
3.5 Verification Findings
The results of the verification risk assessment provided the basis for the verification procedures. Table 5, below, provides a summary of the
verification procedures where discrepancies were detected. Table 6, which follows, provides a description of every verification procedure that
was completed.
Detailed working papers regarding the verification procedures are available on request.
Table 5: Verification Findings Summary
There were no unresolved discrepancies detected in the final GHG Assertion.
Activity Data / Inventory
Component Description Discrepancy Description
Discrepancy
Type
Discrepancy
Magnitude
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
15
Table 6: Findings of Verification Procedures
Activity Data / Inventory
Component Description
Verification Procedures Verification Findings
GENERAL APPLICABILITY REQUIREMENTS
Ownership must be clearly
defined
Substantive test: Confirm ownership
of facilities through the BC Oil & Gas
Commission Data Centre.
A review of facility data through Petrinex and the BC Oil & Gas
Commission Data Centre, as well as company annual reports, showed
that Responsible Party owns and operates the facilities where the
project is implemented.
Observations during the site visit did not indicate the ownership by any
other entity than the Responsible Party.
No discrepancies detected.
ISO 14064-2 REQUIREMENTS
Project information Substantive test – review all
information provided in the GHG
Report, comparing it to
observations made during the site
visit and data and documentation
provided by the Responsible Party.
Confirm that all required data is
included in the report and is
accurate.
The project information described in the GHG Report accurately
represents the baseline and project conditions and the quantification of
the emission reduction, as observed during the site visit.
No discrepancies detected.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
16
Activity Data / Inventory
Component Description
Verification Procedures Verification Findings
Definition and selection of
Sources, Sinks and Reservoirs
(SSRs)
Substantive test – review the GHG
Report and supporting
documentation, comparing the
selection of SSRs described in
these documents to observations
made during the site visit. Evaluate
the justifications provided for
excluding SSRs, confirming that a
conservative approach has been
applied.
The SSRs described in the GHG Report and the selection of SSRs for
quantification appropriately represents the relevant SSRs observed
during the site visit.
No discrepancies detected.
Data monitoring for each
quantification parameter
Substantive test – review the data
monitoring plan for each
quantification parameter, evaluating
for completeness and relevance
based on understanding of the
overall project. Review level of
transparency in project data to
confirm sufficient transparency to
conduct the verification at a
reasonable level of assurance and
meet the needs of the intended
user.
The monitoring plan for each parameter was reviewed and found to
describe the components required to sufficiently monitor the
parameter.
The project data has been provided at a sufficient frequency to conduct
the verification.
No discrepancies detected.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
17
Activity Data / Inventory
Component Description
Verification Procedures Verification Findings
BOUNDARY CONDITIONS
Emission sources Substantive test: Review provided
documentation for errors, omissions
and abnormalities.
Substantive test: Interview field
personnel and observe facility
during site tour to confirm possible
emission sources.
Substantive test: Interview field
personnel and observe facility
during site tour to confirm that
waste heat would be dissipated in
absence of the Project (no
alternative uses of waste heat).
All emission sources reviewed were found to be included in the GHG
Assertion.
The GHG Report describes a natural gas heater used in the case of
interruption to the waste heat recovery system. Since additional
required heat would also be produced by natural gas heaters in the
baseline condition, this source is not included in the calculation of the
emission reduction. Only the amount of heat recovered from the
turbines is considered for the baseline and project conditions.
ARC Resources personnel confirmed during the site visit that recovered
waste heat is only used for transfer to the process heat medium.
No discrepancies detected.
Reporting period Substantive test: Confirm data is
relevant to the reporting period
defined by reference criteria.
Review of all data used for the emission reduction calculation was
confirmed for activities that occurred during the reporting period.
No discrepancies detected.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
18
Activity Data / Inventory
Component Description
Verification Procedures Verification Findings
METHODOLOGIES
Emission quantification
methodologies
Substantive test: Confirm
methodologies are consistent with
reference criteria.
The GHG Report presents emission quantification methodologies and
states that they are consistent with the Alberta Quantification Protocol
for Waste Heat Recovery, Version 2.0. The methodologies in the GHG
Report and the referenced protocol were reviewed and found to be
consistent with the methodologies used to quantify the emissions
reduction.
No discrepancies detected.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
19
Activity Data / Inventory
Component Description
Verification Procedures Verification Findings
Emission quantification
relevance
Substantive test: Evaluate functional
equivalence, baseline condition,
project condition, boundary and
additionality as described by the
Responsible Party. Confirm that
operating conditions are
represented by the information
presented in the GHG Report for
these parameters.
The project meets the conditions for functional equivalence as the level
of service and quality of product delivered in the project condition
remains the same as in the baseline condition. Recovered waste heat is
only used for transfer to the process heat medium.
The calculation of fuel demand and associated emissions from
extraction, processing and combustion in the baseline is estimated
based on WHR operating time, process heat medium inlet and outlet
temperatures, and flow rates. Manufacturer’s specifications for the
process heat medium are used to estimate the fuel demand in the
baseline condition.
Fuel consumption for natural gas heaters in the project condition, in the
case of WHR system interruption, would be equivalent in the baseline
condition as heat would also be provided by natural gas heaters. There
is no electricity consumption in the project condition.
Based on our review, all appropriate SSRs are included in the emission
reduction calculation.
Regarding additionality, this is a greenfield project and there are no
conditions prior to project initiation. In standard industry practice, waste
heat from turbines would be vented to the atmosphere. Implementation
of the project did not occur without the economic incentive of revenue
from the sale of emission offset credits.
No discrepancies detected.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
20
Activity Data / Inventory
Component Description
Verification Procedures Verification Findings
ACTIVITY DATA
WHR unit operating hours Substantive test: Compare
operating hours with process heat
medium fluid flowrate data and
identify any anomalies.
Substantive test: Confirm accurate
transcription of values into
quantification spreadsheet.
A validation was performed using original 15-minute increment data to
determine if any anomalous medium fluid flowrates were included in the
calculated WHR operating hours. No anomalies were detected with
regards to this data.
A validation was also performed to evaluate the calculated monthly
WHR operating hours. This activity data was found to reasonably
match the operating hours presented in the calculation spreadsheet.
No discrepancies detected.
Substantive test: Review activity
data for completeness and identify
any anomalies.
The Dawson IV WHR units became operational in March 2020. The first
day of gas sales from that plant was March 31, 2020 and therefore only
data from that date onwards was included in the emission reduction
calculation.
No discrepancies detected.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
21
Activity Data / Inventory
Component Description
Verification Procedures Verification Findings
Process heat medium fluid inlet
temperature, outlet
temperature and flowrate
Substantive test: Confirm accurate
transcription of values into
quantification spreadsheet and
review engineering estimates for
appropriateness.
Controls test: Review meter
maintenance records.
A validation was performed using original 15-minute increment data on
the monthly averages used in the emission reduction calculation. The
monthly averages for the process heat medium inlet temperature, outlet
temperature and flow rate, as well as the WRH operating hours, were
found to reasonably match those presented in the calculation
spreadsheet.
The emission reduction calculation used devised formulas to calculate
the process heat medium density and specific heat based on tables
from the manufacturer’s specifications. These formulas were tested,
and inputted values returned the expected results.
Calibration and maintenance tags were observed on the waste heat
recovery units during the site visit.
No discrepancies detected.
Substantive test: Review activity
data for completeness and identify
any anomalies.
Substantive test: Observe
equipment and metering locations
during site tour.
A validation was performed using original 15-minute increment data to
determine if any gaps or abnormal values were present in the activity
data. Data where the flow rate was below a certain threshold or where
there was no temperature increase in the heat medium through the
system was excluded for use in the emission reduction calculation by
the Responsible Party.
The WHR units were observed during the site visit.
No discrepancies detected.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
22
Activity Data / Inventory
Component Description
Verification Procedures Verification Findings
Natural gas composition Substantive test: Confirm the
accurate transcription of the gas
analysis data and review
compositions for abnormal
concentrations.
The transcription of the natural gas compositions from the gas analyses
to the calculation spreadsheet was found to be accurate. No anomalies
were detected in the gas composition data.
Gas sampling and frequency was discussed during the site visit. Gas
analyses are conducted periodically by an accredited laboratory. One
gas analysis was available for the reporting period. This meets the
required frequency stated in the Protocol.
No discrepancies detected.
Natural gas emission factors Substantive test: Compare emission
factors used in quantification to
reference sources.
The Responsible Party used a calculated site-specific CO2 emission
factor for natural gas combustion. We agree that this is more
appropriate than using the reference default factor.
Emission factors for CH4 and N2O for natural gas combustion used in
the emission reduction calculation are those required for mandatory
emission reporting in British Columbia. These emission factors have the
same values as those indicated by the reference source.
No discrepancies detected.
QUANTIFICATION
Emission quantification Substantive test: Perform
independent calculations of
emissions.
The recalculation of the emission reduction reasonably matched the
Responsible Party’s quantification.
No discrepancies detected.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
23
Activity Data / Inventory
Component Description
Verification Procedures Verification Findings
DATA INTEGRITY
Activity data and emission
factor data integrity
Substantive test: Use data from
original source for quantification
calculations where possible.
Substantive test: Confirm data
collection procedures through
observation and inquiry during the
site visit.
The activity data were reviewed to detect any abnormal values, zeroes
or missing data amongst the data provided.
No discrepancies detected.
All inventory emission and
reporting quantities
Substantive test: Confirm accurate
transcription from GHG calculation
to final reporting documents.
The final emission reduction quantities were correctly transcribed into
the GHG Report.
No discrepancies detected.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
24
3.6 Verification Records
All records used to conduct the verification will be maintained by Brightspot for seven years from the
date of this report.
3.7 Facts discovered after the verification
If any facts are discovered after the completion of the verification that may result in a mater
discrepancy, Brightspot will notify the project proponent and GHG CleanProjects® Registry within
seven days.
3.8 Verification Schedule
The verification was completed according to the schedule established between the Responsible Party
and the Verifier in the Verification Plan. The verification reached important milestones on the following
dates:
• Verification Kickoff Meeting: July 28, 2020
• Site Visit: August 13, 2020
• Final GHG Report September 8, 2020
• Draft Verification Report : September 8, 2020
• Final Verification Report September 10, 2020
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
25
4 Verification Statement
CSA CleanProjects® Registry
178 Rexdale Blvd.
Toronto, ON
Canada M9W 1R3
September 10, 2020
Introduction
ARC Resources Ltd. (the “Responsible Party”) engaged Brightspot Climate Inc. (Brightspot Climate) to
review their greenhouse gas (GHG) emission reduction and removal project, ARC Resources Waste
Heat Recovery Project (the “Project”). The Project was developed the Alberta Quantification Protocol for
Waste Heat Recovery, Version 2.0, dated June 2018 (the “Methodology”).
The Responsible Party’s “GHG Assertion” is comprised of the GHG Report and supporting
documentation. The GHG Assertion covers the reporting period January 1, 2020 to April 30, 2020 and
states an emission reduction and removal claim of 8,427 tonnes CO2e over this period.
The emission reduction and removal claims consist of no vintage credits.
The Responsible Party is responsible for the preparation and presentation of the information within the
GHG Assertion. Our responsibility as the verifier is to express an opinion as to whether the GHG
Assertion is materially correct, in accordance with the requirements of the CSA CleanProjects® Registry
and the requirements of ISO 14064-2: Specification with guidance at the project level for quantification,
monitoring and reporting of greenhouse gas emission reductions or removal enhancements.
Scope
We completed our review in accordance with ISO 14064 Part 3: Greenhouse Gases: Specification with
Guidance for the Validation and Verification of Greenhouse Gas Assertions (ISO, 2006). As such, we
planned and performed our work to provide positive, but not absolute assurance with respect to the
GHG Assertion.
The verification procedures that were performed through the course of the verification were developed
based on the results of a risk assessment that was completed during the verification planning stage.
These verification procedures are described in the Verification Report.
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
26
Conclusion
I believe our work provides a reasonable basis for my conclusion.
There were no unresolved discrepancies detected in the final GHG Assertion.
Based on our review, it is my opinion at a reasonable level of assurance that the GHG Assertion is
materially correct and presented fairly in accordance with the relevant criteria.
Sincerely,
Aaron Schroeder, P.Eng.
Brightspot Climate Inc.
Westmount, Quebec
Brightspot Climate Inc. – Verification Report ARC Resources Waste Heat Recovery Project
27
5 Conflict of Interest Statement
Brightspot Climate monitored threats to independence throughout the duration of the project. The
following declaration affirms that the following principles were upheld:
Yes No Details
Independence:
The verifying organization remained independent of the activity being
verified, and free from bias and conflict of interest.
The verifying organization maintained objectivity throughout the
verification to ensure that the findings and conclusions are based on
objective evidence generated during the verification,
a N/A
Ethical Conduct:
The verifying organization demonstrated ethical conduct through
trust, integrity, confidentiality and discretion throughout the verification
process.
a N/A
Fair Presentation:
The verifying organization reflected truthfully and accurately
verification activities, findings, conclusions and reports.
The verifying organization reported significant obstacles encountered
during the verification process, as well as unresolved, diverging
opinions among verifiers, the responsible party and the client.
a N/A
Due Professional Care:
The verifying organization exercised due professional care and
judgment in accordance with the importance of the task performed
and the confidence placed by clients and intended users.
Members of the verification team have the necessary skills and
competences to undertake the verification.
a N/A
Date: September 10, 2020
Location: Westmount, Québec
Signed:
Aaron Schroeder
Lead Verifier. Brightspot Climate
28
6 Statement of Qualifications
Lead Verifier Details
Lead Verifier Name: Aaron Schroeder
Professional Designation: Professional Engineer
Email: [email protected]
Phone Number: +1 (604) 353-0264
Verifying Company Name: Brightspot Climate Inc.
Lead Verifier Training
• GHG Verification - ISO 14064-3, Canadian Standards Association, 2012
• CCP 403 - GHG Validation and Verification, University of Toronto, 2016 (Instructor)
Verification Team Biographies
Lead Verifier: Aaron Schroeder, P.Eng. has twelve years of professional experience analyzing,
quantifying and auditing greenhouse gas emissions in North America. Mr. Schroeder’s hands on
experience conducting over 150 greenhouse gas verifications includes numerous engagements for
industrial facilities in power generation, oil and gas production and processing, natural gas pipelines and
a wide range of emission reduction projects in beef and dairy management, conservation cropping
(zero-tillage) and nitrogen fertilizer management, and renewable energy and waste management. Mr.
Schroeder is a sessional instructor at the University of Toronto’s School of Environment for professional
development. He instructs the school’s greenhouse gas quantification and verification courses.
Associate Verifier: Katja Hetmanchuk, Jr. Eng. With ISO 14064-3 training and experience in greenhouse
gas verifications for projects related to oil and gas production, electricity generation and industrial food
processing, Katja is a junior engineer who also has experience analyzing, evaluating and implementing
environmental regulatory requirements. She has conducted case studies analyzing climate change
mitigation within the framework of impact assessments, including the role of greenhouse gas (GHG)
programmes. Prior to joining Brightspot, Katja tracked and analyzed environmental compliance
obligations for companies, performed environmental site assessments, and contributed to site
remediation projects.
Associate Verifier: Rodrigo Cubedo, EIT. Rodrigo completed a Bachelor’s in Mechanical Engineering at
McGill University in 2016. Rodrigo also completed the GHG Validation and Verification, ISO 14064-3, at
University of Toronto in 2019. Following his undergraduate degree Rodrigo worked at
PricewaterhouseCoopers in Hong Kong (PwC HK), where he leveraged his engineering experience to
understand and systematically improve the processes used to work with international clients operating
in the Chinese market. At Brightspot, Rodrigo conducts GHG quantification, reporting, facility report
verifications, offset project verifications, regulatory compliance strategy, emissions and emission
reduction forecasting.
29
Peer Reviewer: Deepika Mahadevan, P.Eng. conducted an independent peer review of the verification.
Ms. Mahadevan has more than five years of experience conducting greenhouse gas verifications for
industrial facilities and emission reduction (offset) projects in jurisdictions across Canada. She has
completed specific training for the application of ISO 14064-3.
I, Aaron Schroeder, meet or exceed the qualifications required for third-party verifiers defined by the CSA Clean Projects Registry.
Aaron Schroeder, P.Eng.
Brightspot Climate Inc.
Westmount, Quebec
1
Introduction
This document serves to communicate information between the parties associated with the independent verification of the emission report.
This document contains four sections:
1. The Introduction, which defines the principles by which this verification will be conducted;
2. The Verification Plan, which defines the verification parameters and the GHG inventory principles that will be tested by the verification. This section also provides information regarding the verification team and site visit;
3. The Evidence-Gathering Activities, which describes the potential sources of risk in the overall GHG report and the evidence-gathering activities that have been developed to reduce the overall verification risk; and
4. The Approval, which confirms that this Verification Plan has been reviewed and approved by the Lead Verifier.
GHG Quantification Principles
ISO 14064-1 defines five principles that are fundamental to the fair accounting and reporting of GHG information. The evidence-gathering activities will test that these principles have been upheld through the Responsible Party’s inventory, accounting and reporting processes.
Section 3.2 – 3.6 of ISO 14064-1 defines these principles as follows:
Accuracy: reduce bias and uncertainty as far as practical
Completeness: include all relevant emission sources
Consistency: enable meaningful comparisons of reported emissions (from year to year or between facilities or between companies)
Relevance: select GHG sources, sinks and reservoirs, data and quantification methodologies appropriate to the needs of the intended user
Transparency: disclose sufficient and appropriate GHG information to facilitate verification and to allow intended users to make decisions with relative confidence
2
Verification Plan ARC Resources Ltd. ARC Resources Waste Heat Recovery Project: January 1, 2020 - April 30, 2020 CSA Clean Projects Registry Verification
Verification Principles
ISO 14064-3 defines four fundamental principles to conducting a greenhouse gas verification, namely independence, ethical conduct, fair presentation and due professional care.
Brightspot Climate has implemented processes, including mandatory training for all verification team members, to ensure the application of these principles for this verification.
Regarding the principle of independence, Brightspot Climate conducted an assessment of threats to independence prior to initiating this verification. No real or perceived threats to independence were identified. Brightspot Climate will continue to monitor for threats to independence throughout the course of this verification. A final “Conflict of Interest Report” will be appended to the Verification Statement.
Verification Parameters
The verification will be conducted according to the plan defined in the following table:
Table 1: Verification Parameters
Responsible Party
ARC Resources Ltd.
Client Modern West Advisory
Type of Engagement
Verification
GHG Program
CSA Clean Projects Registry
Level of Assurance
Reasonable assurance
Objectives
• issue a verification statement on whether the GHG assertion is accurate and conforms with the criteria as listed below;
• issue a verification report that provides details of the verification activities.
3
Criteria
• Quantification Protocol for Waste Heat Recovery, Version 2.0, June 2018. Government of Alberta.
• Final Essential Requirements of Mandatory Reporting, Western Climate Initiative, December 21, 2011
• Project Document - ARC Resources Waste Heat Recovery Project
• ISO 14064-2
Scope
Facility Name: ARC Resources Waste Heat Recovery Project
Organizational Boundary: Operational Control
Geographic Boundary: Dawson III and IV Gas Plant
Physical Operations: Waste heat recovery from combustion
turbines
Emission Sources: Process heat medium heater
Fuel Extraction & Processing
IPCC GHGs Emitted:
Carbon Dioxide (CO2)
Methane (CH4)
Nitrous Oxide (N2O)
Reporting Period: January 1, 2020 – April 30, 2020
Materiality Quantitative materiality threshold is 5% total error
Table 2: Verification Logistics
Verification Team
Lead Verifier Aaron Schroeder, P.Eng.
Associate Verifier Katja Hetmanchuk, Jr. Eng.
Associate Verifier Rodrigo Cubedo, EIT
The Independent Reviewer will be assigned during the verification.
Responsible Party Contact
Kyla Cuthbertson, Environmental Coordinator, ARC Resources Ltd.
4
Verification Schedule
Verification Kickoff Meeting July 28, 2020
Verification Plan to Responsible Party August 12, 2020
Site Visit August 13-14, 2020
Receipt of Data from Responsible Party July 31, 2020
Draft Verification Report August 26, 2020
Final Verification Report and Statement August 31, 2020
5
Evidence-Gathering Activities
A risk assessment was developed in order to identify:
• The risk of material errors, omissions or misrepresentations; and
• Conformance to the requirements of ISO 14064-2 and ISO 14064-3.
Evidence-gathering activities were designed to minimize the verification detection risk associated with each identified source of risk. These activities are identified in Table 3, below. A complete list of findings associated with each evidence-gathering activity will be provided in the Verification Report.
Table 3: Risks and Evidence-Gathering Activities
Source of Risk Evidence-Gathering Activity
GENERAL APPLICABILITY REQUIREMENTS
Ownership must be clearly defined Substantive test: Confirm ownership of facilities through the BC Oil & Gas Commission Data Centre.
ISO 14064-2 REQUIREMENTS
Project information Substantive test – review all information provided in the GHG Report, comparing it to observations made during the site visit and data and documentation provided by the Responsible Party. Confirm that all required data is included in the report and is accurate.
Definition and selection of Sources, Sinks and Reservoirs (SSRs)
Substantive test – review the GHG Report and supporting documentation, comparing the selection of SSRs described in these documents to observations made during the site visit. Evaluate the justifications provided for excluding SSRs, confirming that a conservative approach has been applied.
Data monitoring for each quantification parameter
Substantive test – Review the data monitoring plan for each quantification parameter, evaluating for completeness and relevance based on understanding of the overall project. Review level of transparency in project data to confirm sufficient transparency to conduct the verification at a reasonable level of assurance and meet the needs of the intended user.
BOUNDARY CONDITIONS
6
Source of Risk Evidence-Gathering Activity
Emission sources Substantive test: Review provided documentation for errors, omissions and abnormalities.
Substantive test: Interview field personnel and observe facility during site tour to confirm possible emission sources.
Substantive test: Interview field personnel and observe facility during site tour to confirm that waste heat would be dissipated in absence of the Project (no alternative uses of waste heat).
Reporting period Substantive test: Confirm data is relevant to the reporting period defined by reference criteria.
METHODOLOGIES
Emission quantification methodologies Substantive test: Confirm methodologies are consistent with reference criteria.
Emission quantification relevance Substantive test: Evaluate functional equivalence, baseline condition, project condition, boundary and additionality as described by the Responsible Party. Confirm that operating conditions are represented by the information presented in the GHG Report for these parameters.
ACTIVITY DATA
WHR unit operating hours Substantive test: Compare operating hours with process heat medium fluid flowrate data and identify any anomalies.
Substantive test: Confirm accurate transcription of values into quantification spreadsheet.
Substantive test: Review activity data for completeness and identify any anomalies.
Process heat medium fluid inlet temperature, outlet temperature and flowrate
Substantive test: Confirm accurate transcription of values into quantification spreadsheet and review engineering estimates for appropriateness.
Controls test: Review meter maintenance records.
7
Source of Risk Evidence-Gathering Activity
Substantive test: Review activity data for completeness and identify any anomalies.
Substantive test: Observe equipment and metering locations during site tour.
Natural gas composition Substantive test: Confirm the accurate transcription of the gas analysis data and review compositions for abnormal concentrations.
Natural gas emission factors Substantive test: Compare emission factors used in quantification to reference sources.
QUANTIFICATION
Emission quantification Substantive test: Perform independent calculations of emissions.
DATA INTEGRITY
Activity data and emission factor data integrity
Substantive test: Use data from original source for quantification calculations where possible.
Substantive test: Confirm data collection procedures through observation and inquiry during the site visit.
All inventory emission, production and reporting quantities
Substantive test: Confirm accurate transcription from GHG calculation to final reporting documents.