CENTRAL PUGET SOUND REGIONAL TRANSIT AUTHORITY ARCHITECTURAL STANDARD DRAWINGS AUGUST 2019 DRAWING No.: REV: THE PREPARATION OF THIS DOCUMENT HAS BEEN FINANCED IN PART THROUGH A GRANT FROM THE U.S. DEPARTMENT OF TRANSPORTATION FEDERAL TRANSIT ADMINISTRATION UNDER THE URBAN MASS TRANSPORTATION ACT OF 1964, AS AMENDED, AND IN PART BY THE CENTRAL PUGET SOUND REGIONAL TRANSIT AUTHORITY DISTRICT OF WASHINGTON, AND THE STATE OF WASHINGTON APPROVED BY: DATE: 0 STD-GZT001 MOISES GUTIERREZ DECM DEPUTY EXECUTIVE DIRECTOR DESIGN AND ENGINEERING THESE STANDARD DRAWINGS ARE ISSUED TO ENSURE THE APPLICATION OF UNIFORM STANDARDS FOR THE DESIGN, FABRICATION, INSTALLATION, AND CONSTRUCTION OF SPECIFIC ITEMS OF WORK FOR THE SOUND TRANSIT LINK LIGHT RAIL, SOUNDER, REGIONAL EXPRESS BUS, AND BUS RAPID TRANSIT SYSTEMS, AS DEPICTED HEREIN. IN CONJUNCTION WITH THE DESIGN CRITERIA MANUAL, STANDARD SPECIFICATIONS, AND DIRECTIVE DRAWINGS, THE DESIGNER SHALL INSERT THESE STANDARD DRAWINGS INTO THE PROJECT CONTRACT DOCUMENTS. THE DESIGNER SHALL USE THESE STANDARD DRAWINGS IN THE DESIGN OF INTERFACE POINTS AND PROJECT SPECIFIC ITEMS OF WORK. THESE STANDARD DRAWINGS DO NOT EXEMPT THE CONSULTANT FROM THE PROFESSIONAL RESPONSIBILITY OF DEVELOPING AN APPROPRIATE DESIGN AND COMPLYING WITH THE STANDARD OF CARE. IF THE DESIGNER IDENTIFIES THAT AN ASPECT OR ASPECTS OF THESE STANDARD DRAWINGS ARE INAPPROPRIATE FOR INSERTION IN THE FINAL DESIGN, THE DESIGNER SHALL INFORM AND SECURE CONCURRENCE FROM THE SOUND TRANSIT CORRIDOR DESIGN MANAGER OR PROJECT MANAGER AS PART OF DESIGN MILESTONE SUBMITTALS. SOUND TRANSIT MAKES THESE DOCUMENTS AVAILABLE ON AN AS-IS BASIS. UPDATING THE STANDARD DRAWINGS IS AN ONGOING PROCESS AND REVISIONS ARE ISSUED REGULARLY. COMMENTS, QUESTIONS, AND IMPROVEMENT IDEAS ARE WELCOMED. PLEASE SEND ALL COMMENTS TO DECM DEPUTY EXECUTIVE DIRECTOR OF DESIGN AND ENGINEERING. APPROVED BY: DATE: JULIE MONTGOMERY DECM DIRECTOR OF ARCHITECTURE & ART uncontrolled document from soundtransit.org
Transcript
Page 1: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

CENTRAL P UGET S OUND REGI ONAL TRANSIT AUTHORI TY

ARCHITECTURAL

STANDARD DRAWINGS

AUGUST 2019

DRAWING No.:

REV:

THE PREPARATION OF THIS DOCUMENT HAS BEEN FINANCED IN PART THROUGH A GRANT FROM THE

U.S. DEPARTMENT OF TRANSPORTATION FEDERAL TRANSIT ADMINISTRATION UNDER THE URBAN

MASS TRANSPORTATION ACT OF 1964, AS AMENDED, AND IN PART BY THE CENTRAL PUGET SOUND

REGIONAL TRANSIT AUTHORITY DISTRICT OF WASHINGTON, AND THE STATE OF WASHINGTON

APPROVED BY: DATE:

0

STD-GZT001

MOISES GUTIERREZ

DECM DEPUTY EXECUTIVE DIRECTOR DESIGN AND ENGINEERING

THESE STANDARD DRAWINGS ARE ISSUED TO ENSURE THE APPLICATION OF UNIFORM STANDARDS FOR THE

DESIGN, FABRICATION, INSTALLATION, AND CONSTRUCTION OF SPECIFIC ITEMS OF WORK FOR THE SOUND

TRANSIT LINK LIGHT RAIL, SOUNDER, REGIONAL EXPRESS BUS, AND BUS RAPID TRANSIT SYSTEMS, AS

DEPICTED HEREIN. IN CONJUNCTION WITH THE DESIGN CRITERIA MANUAL, STANDARD SPECIFICATIONS, AND

DIRECTIVE DRAWINGS, THE DESIGNER SHALL INSERT THESE STANDARD DRAWINGS INTO THE PROJECT

CONTRACT DOCUMENTS. THE DESIGNER SHALL USE THESE STANDARD DRAWINGS IN THE DESIGN OF

INTERFACE POINTS AND PROJECT SPECIFIC ITEMS OF WORK.

THESE STANDARD DRAWINGS DO NOT EXEMPT THE CONSULTANT FROM THE PROFESSIONAL

RESPONSIBILITY OF DEVELOPING AN APPROPRIATE DESIGN AND COMPLYING WITH THE STANDARD OF CARE.

IF THE DESIGNER IDENTIFIES THAT AN ASPECT OR ASPECTS OF THESE STANDARD DRAWINGS ARE

INAPPROPRIATE FOR INSERTION IN THE FINAL DESIGN, THE DESIGNER SHALL INFORM AND SECURE

CONCURRENCE FROM THE SOUND TRANSIT CORRIDOR DESIGN MANAGER OR PROJECT MANAGER AS PART

OF DESIGN MILESTONE SUBMITTALS.

SOUND TRANSIT MAKES THESE DOCUMENTS AVAILABLE ON AN AS-IS BASIS. UPDATING THE STANDARD

DRAWINGS IS AN ONGOING PROCESS AND REVISIONS ARE ISSUED REGULARLY. COMMENTS, QUESTIONS,

AND IMPROVEMENT IDEAS ARE WELCOMED. PLEASE SEND ALL COMMENTS TO DECM DEPUTY EXECUTIVE

DIRECTOR OF DESIGN AND ENGINEERING.

APPROVED BY: DATE:

JULIE MONTGOMERY

DECM DIRECTOR OF ARCHITECTURE & ART

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 2: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

DISCLAIMER FOR

Design and Engineering Design Standards Documents

Sound Transit makes these documents available on an "as is" basis. By accepting receipt of the documents, the receiver agrees to the following:

The documents are provided for information only;

The receiver will not utilize the documents in any way that violates or infringes on Sound Transit’s intellectual property rights in such documents;

The provided documents should not be construed to represent formal design guidance and/or direction for any project;

Sound Transit makes no representation or warranty that the provided data is complete, appropriate, or fit for any particular purpose, stated or otherwise;

All documents provided by Sound Transit, including any revisions, shall remain the personal and intellectual property of Sound Transit; and

To indemnify, defend, and hold harmless Sound Transit, its consultants, and agent(s) from any and all damages and claims arising from the receiver’s use of these documents.

APPLICABILITY FOR

Design and Engineering Design Standards Documents

Project teams shall refer to their executed project contracts for applicable document versions/revisions.

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 3: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

GENERAL

DWG. No. TITLEREV

STD-GZT001 0 COVER SHEET

STD-GZI001 0 INDEX OF DRAWINGS

AT-GRADE CENTER PLATFORM ENTRY LAYOUT

STD-GZI001 0 INDEX OF DRAWINGS

STD-APP211 0 AT-GRADE CENTER PLATFORM ENTRY LAYOUT

STD-APP212 0 AT-GRADE SIDE PLATFORM ENTRY LAYOUT

STD-ATD222 0 PUBLIC STAIRS RUNNEL DETAILS

STD-AVD228 0 ELEVATORS CABS WITH GLAZING AT SIDES

STD-AID240 0 RESTROOMS

STD-APP270 1 INFORMATION KIOSK AT CENTER PLATFORM

STD-APP271 1 INFORMATION KIOSK AT SIDE PLATFORM

STD-ADD280 0 WINDSCREENS AT CENTER PLATFORM

STD-ASD301 0 TICKET VENDING MACHINE AND SMART CARD READERS

STD-ASD3050

EQUIPMENT MOUNTING ELEVATIONS AND DETAILS

STD-ATD325 0 EXIT STAIR DETAILS

STD-AVD340 0 ELEVATOR DETAILS

STD-AID370 0 TOILET ACCESSORIES

STD-AND500 0 SIGNAGE TYPES

STD-AND501 0 SIGNAGE MOUNTING DETAILS

STD-AND502 0 SIGNAGE MOUNTING DETAILS

INDEX OF DRAWINGS

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

09

/1

0/1

9 | 9

:2

9 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\G

UID

AN

CE

-S

TA

ND

AR

D_

DR

AW

IN

GS

- W

OR

KIN

G\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-G

ZI0

01

.D

WG

STD-GZI001

FACILITY ID:

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

N/A

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

INDEX OF DRAWINGS

STD-GZI001

0

1 8/2019 NEW - ARCH DIRECTIVE AND STANDARD DWGS

ARCHITECTURAL

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 4: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

16'-0" FOR 2 TVM LAYOUT

20'-0" FOR 3 TVM LAYOUT

TVM

48"

30

"

BENCH

8'-0

" M

IN

. A

FF

9'-0

" M

IN

. A

FF

6'-0"

EDGE OF

PLATFORM

4'-0" FOR 3

TVM LAYOUT

BENCH

6'-0"

16'-0" (4 MODULES @ 4'-0" EACH)

FOR 2 TVM LAYOUT

2'-0" MIN

4'-0" MAX

2'-0 MIN

4'-0" MAX

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

10

/3

0/1

9 | 9

:4

2 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\D

IR

EC

TIV

E-S

TA

ND

AR

D_

DR

AW

IN

GS

\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-A

PP

21

1.D

WG

STD-APP211

FACILITY ID:

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

1/4" = 1'-0"

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

AT-GRADE CENTER PLATFORM

ENTRY LAYOUT

STD-APP211

0

SCALE: 1/4" = 1'-0"

ELEVATIONB

-

CUSTOMER

INFORMATION

PANELS

PASSENGER

EMERGENCY

TELEPHONE

BARRIER

(42" MIN HGT)

JUNCTION BOX

FOR FUTURE

TRIP PLANNER

STATION

APPROACH

RAMP

IF REQD

AT 3 TVM

LAYOUTS

SMART CARD READER

PLATFORM EDGE

DETECTABLE

WARNING SURFACE

PLATFORM EDGE

DETECTABLE

WARNING SURFACE

SMART CARD READER

FARE PAID ZONE

SIGN ABOVE

TELEPHONE CO DEMARCATION CABINET &

COMMUNICATIONS DISTRIBUTION PANEL

WHERE REQUIRED

SIGNAGE MOUNTING

HEIGHT WHEN

CIRCULATION BELOW

SIGNAGE MOUNTING

HEIGHT ALLOWED WHEN

NO CIRCULATION BELOW

FARE PAID

ZONE SIGN

JUNCTION BOX FOR FUTURE

TRIP PLANNER PROVIDE (1)

1"C PWR AND (1) 1"C DATA

PASSENGER EMERGENCY TELEPHONE CUSTOMER INFORMATION PANELS

SMART CARD READER

19

'-0

"4

'-7

1

/4

"

1'-0

"

TY

P

AT 2 TVM

LAYOUTS

4'-7

1

/4

"

1'-0

"

TY

P

CL

T

RA

CK

CL

T

RA

CK

CL

P

LA

TF

OR

M

OPP

8'-0

" A

FF

9'-0

" A

FF

16'-0" (4 MODULES @ 4'-0" EACH)

2'-0" MIN

4'-0" MAX 6'-0"

RAMP

IF REQD

ACCESS PANEL TO TELEPHONE

CO DEMARCATION CABINET AT

COMMUNICATIONS DISTRIBUTION

PANEL WHERE REQUIRED

FARE PAID

ZONE SIGN

SMART

CARD

READER

TICKET

VENDING

MACHINES

OPTIONAL CUSTOMER

INFORMATION PANELS

SIGNAGE MOUNTING

HEIGHT WHEN

CIRCULATION BELOW

SIGNAGE MOUNTING

HEIGHT ALLOWED

WHEN NO CIRCULATION

BELOW

SYSTEM

INFORMATION

PANELS

BENCH

20'-0" (5 MODULES @ 4'-0" EACH)

6'-0"

2'-0" MIN

4'-0" MAX

RAMP

IF REQD

TICKET VENDING

MACHINES

TICKET VENDING MACHINEOPTIONAL CUSTOMER

INFORMATION PANELS

CUSTOMER

INFORMATION

PANELS

ACCESS PANEL TO TELEPHONE

CO DEMARCATION CABINET AT

COMMUNICATIONS DISTRIBUTION

PANEL WHERE REQUIRED

FARE PAID

ZONE SIGN

SMART

CARD

READER

TYP

BENCH

48"

30

"

TVM

BENCH

SCALE: 1/4" = 1'-0"

ELEVATIOND

-SCALE: 1/4" = 1'-0"

ELEVATIONC

-

0 8/2019 NEW - ARCH DIRECTIVE AND STANDARD DWGS

B

-

D

-

C

-

A

STD-APD360

B

STD-ASD301

GENERAL NOTES:

1. THIS PLAN INDICATES A PROTOTYPICAL CONFIGURATION LAYOUT ONLY.

SPECIFIC STATION REQUIREMENTS AND LAYOUTS WILL VARY.

2. DASHED LINES AT TVM EQUIPMENT PLAN INDICATE ADA APPROACH SPACE.

PARALLEL ADA APPROACH IS ASSUMED.

3. REFER TO SOUND TRANSIT CUSTOMER SIGNAGE MANUAL TO DETERMINE

MOUNTING HEIGHTS FOR SYSTEMS INFORMATION PANELS, PASSENGER

EMERGENCY TELEPHONE, AND TRIP PLANNER.

TACTILE

WAYFINDING

PATH

SCALE: 1/4" = 1'-0"

PLAN A

DIR-APP131

DIR-APP135

1'-0

"

REGISTERED

ARCHITECT

STATE OF WASHINGTON

JULIE ANNE MONTGOMERY

8073

FARE PAID ZONE

FLOORING DEMARCATION

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 5: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

24'-0"

12

'-0

"4

'-7

1

/4

"

TVM

48"

30

"

BENCH

8'-0

" M

IN

. A

FF

9'-0

" M

IN

. A

FF

6'-0"

RAMP

IF REQD

END OF

PLATFORM

TYP

4'-0" MAX

2'-0" MIN

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

08

/0

8/1

9 | 1

1:3

0 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\G

UID

AN

CE

-S

TA

ND

AR

D_

DR

AW

IN

GS

- W

OR

KIN

G\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-A

PP

21

2.D

WG

STD-APP212

FACILITY ID:

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

AS NOTED

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

AT-GRADE SIDE PLATFORM

ENTRY LAYOUT

STD-APP212

0

1'-0

"

TY

P

CL

T

RA

CK

B

-

1

STD-APD360

B

STD-ASD301

SCALE: 1/4" = 1'-0"

ELEVATION B

-

TVM

TELEPHONE CO DEMARCATION

CABINET AND COMMUNICATIONS

DISTRIBUTION PANEL WHERE

REQUIRED

ALTERNATE LOCATION FOR

TELEPHONE CO DEMARCATION

CABINET AND COMMUNICATIONS

DISTRIBUTION PANEL WHERE

REQUIRED

OPTIONAL 3RD TVM LOCATION

CUSTOMER INFORMATION

PANEL

PASSENGER EMERGENCY TELEPHONE

JUNCTION BOX FOR

FUTURE TRIP PLANNER

FACE OF BARRIER (42" MIN HGT)

48"

30

"

GUARDRAIL OR SIM

SMART CARD READER, TYP

FARE PAID ZONE

SIGN ABOVE

PLATFORM EDGE

DETECTABLE

WARNING SURFACE

BENCH

ALTERNATE LOCATION FOR TELEPHONE

CO DEMARCATION CABINET AND

COMMUNICATIONS DISTRIBUTION PANEL

WHERE REQUIRED

PASSENGER EMERGENCY TELEPHONE

SIGNAGE MOUNTING HEIGHT

WHEN CIRCULATION BELOW

SIGNAGE MOUNTING HEIGHT ALLOWED

WHEN NO CIRCULATION BELOW

JUNCTION BOX FOR FUTURE

TRIP PLANNER PROVIDE

(1) 1"C PWR AND (1) 1"C DATA

CUSTOMER

INFORMATION

PANELS

3RD TVM LOCATION

(OR FUTURE)

OPTIONAL

CUSTOMER

INFORMATION PANEL

SMART CARD

READER

TICKET VENDING

MACHINE

PROVIDE ACCESS PANEL TO TELEPHONE

CO DEMARCATION CABINET &

COMMUNICATIONS DISTRIBUTION PANEL

WHERE REQUIRED

FARE PAID ZONE SIGN ALIGN

WITH ORCA CARD READER

OPTIONAL 4'-0" SPACE FOR

ADDITIONAL SIGNAGE IF

NEEDED. IF NOT USED

PROVIDE 2'-0" MIN TO SAFTP

SCALE: 1/4" = 1'-0"

ELEVATION C

-

8'-0

" M

IN

. A

FF

9'-0

" M

IN

. A

FF

TYP

B

STD-ASD301

BENCH

ALTERNATE LOCATION FOR TELEPHONE

CO DEMARCATION CABINET AND

COMMUNICATIONS DISTRIBUTION PANEL

WHERE REQUIRED

PASSENGER EMERGENCY TELEPHONE

SIGNAGE MOUNTING HEIGHT

WHEN CIRCULATION BELOW

SIGNAGE MOUNTING HEIGHT ALLOWED

WHEN NO CIRCULATION BELOW

JUNCTION BOX FOR

FUTURE TRIP PLANNER

SMART CARD

READER

TICKET VENDING

MACHINE

PROVIDE ACCESS PANEL TO

TELEPHONE CO DEMARCATION CABINET

& COMMUNICATIONS DISTRIBUTION

PANEL WHERE REQUIRED

FARE PAID ZONE SIGN ALIGN

WITH ORCA CARD READER

OPTIONAL 4'-0" SPACE FOR

ADDITIONAL SIGNAGE IF

NEEDED. IF NOT USED

PROVIDE 2'-0" MIN TO SAFTP

CUSTOMER

INFORMATION

PANELS

20'-0"

12

'-0

"4

'-7

1

/4

"

48"

30

"

6'-0"

RAMP

IF REQD

END OF

PLATFORM

4'-0" MAX

2'-0" MIN

1'-0

"

TY

P

CL

T

RA

CK

C

-

1

STD-APD360

TELEPHONE CO DEMARCATION

CABINET AND COMMUNICATIONS

DISTRIBUTION PANEL WHERE

REQUIRED

CUSTOMER

INFORMATION

PANEL

PASSENGER EMERGENCY TELEPHONE

JUNCTION BOX FOR

FUTURE TRIP PLANNER

FACE OF BARRIER (42" MIN HGT)

GUARDRAIL OR SIM

SMART CARD READER, TYP

FARE PAID ZONE

SIGN ABOVE

PLATFORM EDGE

DETECTABLE

WARNING SURFACE

BENCH

48"

30

"

TVMTVM

0 8/2019 NEW - ARCH DIRECTIVE AND STANDARD DWGS

GENERAL NOTES:

1. THIS PLAN INDICATES A PROTOTYPICAL CONFIGURATION FOR A 3 TVM LAYOUT

ONLY. SPECIFIC STATION REQUIREMENTS AND LAYOUTS WILL VARY.

2. DASHED LINES AT TVM EQUIPMENT PLAN INDICATE ADA APPROACH SPACE.

PARALLEL ADA APPROACH IS ASSUMED.

3. REFER TO SOUND TRANSIT CUSTOMER SIGNAGE MANUAL TO DETERMINE

MOUNTING HEIGHTS FOR CUSTOMER INFORMATION PANELS, AND TRIP PLANNER.

4. REFER TO SYSTEMS GUIDANCE DRAWINGS TO DETERMINE MOUNTING HEIGHTS

FOR PASSENGER EMERGENCY TELEPHONES.

TACTILE WAYFINDING

PATH

TACTILE WAYFINDING

PATH

SCALE: 1/4" = 1'-0"

PLAN - 3 TVM LAYOUT A

DIR-APP131 SCALE: 1/4" = 1'-0"

PLAN - 2 TVM LAYOUT A

DIR-APP131

FARE PAID ZONE

FLOORING DEMARCATION

FARE PAID ZONE

FLOORING

DEMARCATION

REGISTERED

ARCHITECT

STATE OF WASHINGTON

JULIE ANNE MONTGOMERY

8073

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 6: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

08

/0

8/1

9 | 1

1:2

6 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\G

UID

AN

CE

-S

TA

ND

AR

D_

DR

AW

IN

GS

- W

OR

KIN

G\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-A

TD

22

2.D

WG

STD-ATD222

FACILITY ID:

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

AS NOTED

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

PUBLIC STAIRS

RUNNEL DETAILS

STD-ATD222

0

B

-

A

-

SCALE: 1" = 1'-0"

BICYCLE / STAIR / RUNNEL CLEARANCE A

- SCALE: 1" = 1'-0"

LONGITUDINAL SECTION B

- SCALE: 6" = 1'-0"

RUNNEL DETAIL 1

-

72" MIN

VA

RIE

S

STAINLESS

STEEL

HANDRAIL

STAIR TREAD

WALL PANEL OR

RAILING

TYPICAL

BICYCLE

PRECAST

CONCRETE BIKE

RUNNEL

STAINLESS STEEL

HANDRAIL

PRECAST

CONCRETE BIKE

RUNNEL

STAIR TREAD

STAIR TREAD

BEYOND

+/-1 1/2" DIAMETER

BIKE TIRE

PRECAST

CONCRETE

RUNNEL

1'-10"

WALL AS

SCHEDULED

1

-

ANCHOR

0 8/2019 NEW - ARCH DIRECTIVE AND STANDARD DWGS

GENERAL NOTES:

1. BIKE RUNNELS SHALL BE PROVIDED ON BOTH SIDES

OF STRAIGHT STAIRS FOR ASCENT AND DESCENT

(WITHOUT USER CONFLICT).

2. BIKE RUNNELS SHALL BE PROVIDED ON THE OUTER

SIDE OF SWITCHBACK STAIRS ONLY.

STRUCTURE - VARIES

8"

3'-7 1/2"

0'-1

1 1

/2

"

REGISTERED

ARCHITECT

STATE OF WASHINGTON

JULIE ANNE MONTGOMERY

8073

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 7: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

TA-6A

TA-1A

TA-5

TA-6B

WC

TA-4A

LAV

WC

TA-9

LIGHT FIXTURE

TA-6C

SS METAL PANELS

LAV

HOLLOW METAL DOOR

& FRAME

TA-3A

TA-8A

SWITCH

TA-7A

FD

A

D

C

B

TA-6A

TA-9

TA-4A (TA-4 @

TRANSIT DRIVE RR)

LAV

WC

TA-6A

TILE, TYP

TA-5

4'-0"

TA-1A (TA-1 @

TRANSIT DRIVE RR)

TA-6B

TILE

TA-7

TA-8A

HOLLOW METAL DOOR

& FRAME

TA-3A (TA-3 @

TRANSIT DRIVE RR)

TILE

--

1'-6

"

TA-7A

FINISH FLOOR

BO CEILING

8'-0

"

FINISH FLOOR

BO CEILING

8'-0

"

FINISH FLOOR

BO CEILING

8'-0

"

FINISH FLOOR

BO CEILING

8'-0

"

SS METAL PANELSSS METAL PANELSSS METAL PANELS

FINISH FLOOR

BO CEILING

8'-0

"

FINISH FLOOR

BO CEILING

8'-0

"

FINISH FLOOR

BO CEILING

8'-0

"

FINISH FLOOR

BO CEILING

8'-0

"

TILE, TYP

VA

RIE

S

SE

E P

RO

JE

CT

P

LA

NS

VARIES

SEE PROJECT PLANS

VA

RIE

S

SE

E P

RO

JE

CT

P

LA

NS

VARIES

SEE PROJ PLANS

WALL MOUNTED SPACE

HEATER @ STAFF RR ONLY

GYPSUM BOARD

SS METAL PANELS

CHANGING

STATION

CHANGING

STATION

A

D

C

B

--

UR

UR

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

08

/0

8/1

9 | 1

1:2

0 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\G

UID

AN

CE

-S

TA

ND

AR

D_

DR

AW

IN

GS

- W

OR

KIN

G\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-A

ID

24

0.D

WG

STD-AID240

FACILITY ID:

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

1/4" = 1'-0"

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

RESTROOMS

STD-AID240

0

INTERIOR ELEVATION - STAFF/

TRANSIT DRIVER RESTROOM

SCALE: 1/4"=1'-0"

B

-

INTERIOR ELEVATION - STAFF/

TRANSIT DRIVER RESTROOM

SCALE: 1/4"=1'-0"

C

-

INTERIOR ELEVATION - STAFF/

TRANSIT DRIVER RESTROOM

SCALE: 1/4"=1'-0"

D

-

INTERIOR ELEVATION - STAFF/

TRANSIT DRIVER RESTROOM

SCALE: 1/4"=1'-0"

A

-

INTERIOR ELEVATION - PUBLIC

RESTROOM

SCALE: 1/4"=1'-0"

D

-

INTERIOR ELEVATION - PUBLIC

RESTROOM

SCALE: 1/4"=1'-0"

C

-

INTERIOR ELEVATION - PUBLIC

RESTROOM

SCALE: 1/4"=1'-0"

B

-

INTERIOR ELEVATION - PUBLIC

RESTROOM

SCALE: 1/4"=1'-0"

A

-

0 8/2019 NEW - ARCH DIRECTIVE AND STANDARD DWGS

SCALE: 1/4" = 1'-0"

ENLARGED RCP - PUBLIC RESTROOM

SCALE: 1/4" = 1'-0"

ENLARGED RCP - STAFF/

TRANSIT DRIVER RESTROOM

ENLARGED PLAN - STAFF/ TRANSIT

DRIVER RESTROOM

SCALE: 1/4"=1'-0"

2

-

ENLARGED PLAN - PUBLIC

RESTROOM

SCALE: 1/4"=1'-0"

1

-

NOTE:

PUBLIC RESTROOMS

ONLY PROVIDED

WHERE REQUIRED

REGISTERED

ARCHITECT

STATE OF WASHINGTON

JULIE ANNE MONTGOMERY

8073

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 8: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

CL PLATFORM CL VEHICLE DOORCL VEHICLE DOOR

1'-6

"

VE

RIF

Y W

/E

QU

IP

8'-0

" M

IN

. A

FF

9'-0

" M

IN

. A

FF

8'-0" MIN

8'-0

" M

IN

. A

FF

9'-0

" M

IN

. A

FF

8'-0"

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

08

/0

8/1

9 | 1

1:2

9 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\G

UID

AN

CE

-S

TA

ND

AR

D_

DR

AW

IN

GS

- W

OR

KIN

G\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-A

PP

27

0.D

WG

STD-APP270

FACILITY ID:

2'-0

"

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

3/8" = 1'-0"

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

INFORMATION KIOSK

AT CENTER PLATFORM

STD-APP270

1

SCALE: 3/8" = 1'-0"

ELEVATION

B

-

A

-

SCALE: 3/8" = 1'-0"

ELEVATION

A

-

B

-

2

STD-APD360

2

STD-APD360

TACTILE INFORMATION

PANEL

PASSENGER

EMERGENCY

PHONE

SYSTEM

INFORMATION

PANELS

TACTILE

INFORMATION

PANEL

TACTILE TRAIN

WAITING AREA

TACTILE PATH

PLATFORM EDGE DETECTABLE

WARNING SURFACE

20'-0" 20'-0"

3'-0" 3'-0" 3'-0" 3'-0"

8'-0" MIN

SIGNAGE MOUNTING HEIGHT

WHEN CIRCULATION BELOW

SIGNAGE MOUNTING HEIGHT

ALLOWED WHEN NO

CIRCULATION BELOW

PASSENGER EMERGENCY PHONE

SYSTEM INFORMATION PANELS

SYSTEM INFORMATION PANELS

AT CONCRETE

PAVER, TYP

3

STD-APD360

AT TILE, TYP

SIGNAGE MOUNTING HEIGHT

WHEN CIRCULATION BELOW

SIGNAGE MOUNTING HEIGHT

ALLOWED WHEN NO

CIRCULATION BELOW

CL

T

RA

CK

CL

T

RA

CK

CL

P

LA

TF

OR

M

0 6/2013 NEW - CIVIL, ARCH, SYSTEMS GUIDANCE DWGS

1 8/2019 REVISED - ARCH DIRECTIVE AND STANDARD DWGS

GENERAL NOTES:

1. THIS PLAN INDICATES A PROTOTYPICAL CONFIGURATION

LAYOUT ONLY. SPECIFIC STATION REQUIREMENTS AND

LAYOUTS WILL VARY.

2. REFER TO SOUND TRANSIT CUSTOMER SIGNAGE MANUAL TO

DETERMINE MOUNTING HEIGHTS FOR SYSTEMS INFORMATION

PANELS, PASSENGER EMERGENCY TELEPHONE, AND TRIP

PLANNER.

3. HOSE BIBBS AND OUTLETS AT CENTER KIOSKS TO BE

INCLUDED PER THE REQUIREMENTS OF THE SOUND TRANSIT

DESIGN CRITERIA MANUAL.

SCALE: 3/8" = 1'-0"

PLAN

BETWEEN CAR BARRIER

REGISTERED

ARCHITECT

STATE OF WASHINGTON

JULIE ANNE MONTGOMERY

8073

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 9: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

CL PLATFORM CL VEHICLE DOORCL VEHICLE DOOR

PASSENGER

EMERGENCY

PHONE

8'-0

" M

IN

. A

FF

9'-0

" M

IN

. A

FF

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

08

/0

8/1

9 | 1

1:2

8 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\G

UID

AN

CE

-S

TA

ND

AR

D_

DR

AW

IN

GS

- W

OR

KIN

G\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-A

PP

27

1.D

WG

STD-APP271

FACILITY ID:

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

3/8" = 1'-0"

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

INFORMATION KIOSK

AT SIDE PLATFORM

STD-APP271

1

SIGNAGE MOUNTING HEIGHT

WHEN CIRCULATION BELOW

SCALE: 3/8" = 1'-0"

ELEVATION A

-

A

-

2

STD-APD360

3'-0"

TYP

3'-0"

TYP

20'-0" 20'-0"

TACTILE

INFORMATION

PANEL

TACTILE

INFORMATION

PANEL

SYSTEM

INFORMATION

PANELS

TACTILE TRAIN

WAITING AREA

PLATFORM EDGE

DETECTABLE WARNING

SURFACE

TACTILE PATH TACTILE TRAIN

WAITING AREA

SIGNAGE MOUNTING HEIGHT

WHEN CIRCULATION BELOW

SIGNAGE MOUNTING HEIGHT

ALLOWED WHEN NO

CIRCULATION BELOW

PASSENGER

EMERGENCY

PHONE

SYSTEM

INFORMATION

PANELS

2

STD-APD360

AT CONCRETE

PAVER, TYP

3

STD-APD360

AT TILE, TYP

CL

T

RA

CK

2'-0

"

0 6/2013 NEW - CIVIL, ARCH, SYSTEMS GUIDANCE DWGS

1 8/2019 REVISED - ARCH DIRECTIVE AND STANDARD DWGS

GENERAL NOTES:

1. THIS PLAN INDICATES A PROTOTYPICAL

CONFIGURATION LAYOUT ONLY. SPECIFIC STATION

REQUIREMENTS AND LAYOUTS WILL VARY.

2. REFER TO SOUND TRANSIT CUSTOMER SIGNAGE

MANUAL TO DETERMINE MOUNTING HEIGHTS FOR

SYSTEMS INFORMATION PANELS, PASSENGER

EMERGENCY TELEPHONE, AND TRIP PLANNER.

SCALE: 3/8" = 1'-0"

PLAN

BETWEEN CAR

BARRIER

REGISTERED

ARCHITECT

STATE OF WASHINGTON

JULIE ANNE MONTGOMERY

8073

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 10: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

WINDSCREEN SECTION

SCALE: 1"=1'-0"

B

-

WINDSCREEN ELEVATION

SCALE: 1"=1'-0"

A

-

4'-0

"4

'-0

"

CL

VA

RIE

S

4" M

IN

B

-

2

-

4

-

6

-

3

-

5

-

1

-

B

-

A

-

EQ

CL CL

CL

CL

CL

CL

VA

RIE

S - S

EE

S

TA

TO

IN

P

LA

N

EQ EQ

VARIES - SEE STATION PLAN

2

-

4

-

CL

CL

CL

VA

RIE

S

4" M

IN

4'-0

"4

'-0

"

SIM

SIM

6

-

CL

A. TYPICAL SECTION B. SECTION AT CURB

BO ROOF

TO FIN FLR

VA

RIE

S

ROOF WHERE

OCCURS

HSS AT HEADER

HSS WHERE

OCCURS

GLAZING

CURTAIN WALL

COLUMN BEHIND

WINDSCREEN

CONCRETE CURB

WHERE OCCURS

PLATFORM

WALKING

SURFACE

COLUMN

BEYOND

COLUMN BEYOND

COLUMN BEYOND

CURTAIN WALL

PLATFORM

WALKING

SURFACE

METAL PANEL

HSS WHERE

OCCURS

CONCRETE CURB

BELOW WHERE

OCCURS

CURTAIN WALL,

TYP

GLAZING, TYP

WIND SCREEN ENLARGED PLAN

SCALE: 1"=1'-0"

1

-

CL

DIM POINT

1/4

"

AL

IG

N

CL

1/4"

ALIGN

CL

CL

EQ EQ

DIM POINT

CL

AL

IG

N

COLUMN BEYOND

HHS

HHS BRACED

BACK TO COLUMN

BEYOND

BACKER ROD AND

SEALANT, TYP

ISOLATION MATERIAL

ISOLATION MATERIAL

GLAZING

BACKER ROD AND

SEALANT, TYP

CURTAIN WALL

ISOLATION MATERIAL

DIM POINT

GL-2

DIM POINT

CURTAIN WALL

GLAZING

CURTAIN WALL

GLAZING

GLAZING

CURTAIN WALL

GLAZING

CONCRETE CURB

EPOXY SET

ANCHOR PER MFR

GLAZING

CURTAIN WALL

ISOLATION PAD

SHIM, W/ SEALANT &

BACKER ROD

METAL

PANEL

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

08

/0

8/1

9 | 1

1:2

1 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\G

UID

AN

CE

-S

TA

ND

AR

D_

DR

AW

IN

GS

- W

OR

KIN

G\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-A

DD

28

0.D

WG

STD-ADD280

FACILITY ID:

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

AS NOTED

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

WINDSCREENS

AT CENTER PLATFORM

STD-ADD280

0

CORNER MULLION

SCALE: 6"=1'-0"

6

-

SILL @ CONCRETE CURB

SCALE: 6"=1'-0"

7

-

INTERMEDIATE VERTICAL MULLION

SCALE: 6"=1'-0"

4

-

END MULLION

SCALE: 6"=1'-0"

2

-

INTERMEDIATE HORIZONTAL MULLION

SCALE: 6"=1'-0"

5

-

WINDSCREEN HEADER

SCALE: 6"=1'-0"

3

-

0 8/2019 NEW - ARCH DIRECTIVE AND STANDARD DWGS

REGISTERED

ARCHITECT

STATE OF WASHINGTON

JULIE ANNE MONTGOMERY

8073

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 11: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

FIN FLR

8'-0"

2'-10"

EQ EQ

6"

6"

6"

6"

2'-10"

VARIES

VA

RIE

S

OPNG PER PLANS

BO CEILING

FIN FLR

8'-0"

BO CEILING

EQ EQ

EQ EQ EQ

EQ

EQ

EQ

RECESSED LIGHTING, TYP

SPEAKER

1/8" GAPS. TYP

FINISHED SST CEILING

ACCESS PANEL

SECURITY CAMERA

HANDRAIL PER MFR

EPOXY FLOORING

ELEV DOOR JAMB

CAR OPERATING

PANELS

METAL PANEL

SATIN SST BASE

SST HANDRAIL

(1 1/4" MIN /

1 1/2" MAX DIA)

ALIGN MULLION WITH

EXTERIOR MULLION

SST HANDRAIL (1 1/4"

MIN/ 1 1/2" MAX DIA)

LAMINATED TEMPERED

GLAZING, TYP

SATIN SST BASE

4'-0" M

AX

35" M

IN

48" M

AX

FIN FLR

8'-0"

BO CEILING

FIN FLR

8'-0"

BO CEILING

METAL PANEL

GLAZING

CAR POSITION INDICATOR

CAR OPERATING PANEL

COMMUNICATION

SYSTEM

ELEVATOR CONTROL

PANEL BUTTONS, CAB

ALARM, EMERGENCY

STOP BUTTONS

SST BASE

GLAZING VARIES

ELEVATOR CALL

BUTTONS (PANEL)

CL

AL

IG

N

1/2

"

TY

P

1 1/2"

ALL EXPOSED EDGES

SHALL BE FINISHED WITH

FACE MATERIAL, TYP

METAL PANEL, TYP

FINISHED CEILING. ALL

EXPOSED EDGES SHALL

BE FINISHED WITH FACE

MATERIAL.

SST HANDRAIL (1-1/4"

MIN / 1-1/2" MAX DIA)

SST BASE

FINISHED FLOOR

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

08

/0

8/1

9 | 1

1:0

7 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\G

UID

AN

CE

-S

TA

ND

AR

D_

DR

AW

IN

GS

- W

OR

KIN

G\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-A

VD

22

8.D

WG

STD-AVD228

FACILITY ID:

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

AS NOTED

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

ELEVATORS CABS

WITH GLAZING AT SIDES

STD-AVD228

0

INTERIOR ELEVATION - METAL PANEL

SCALE: 1/2"=1'-0"

A

-

INTERIOR ELEVATION - GLAZING

SCALE: 1/2"=1'-0"

B

-

INTERIOR ELEVATION - DOORS

SCALE: 1/2"=1'-0"

C

-

EXTERIOR ELEVATION - DOORS

SCALE: 1/2"=1'-0"

D

-

SECTION - INTERIOR CABS

SCALE: 1 1/2"=1'-0"

E

-

B

-

B

-

A

-

C

-

E

-

0 8/2019 NEW - ARCH DIRECTIVE AND STANDARD DWGS

D

-

ENLARGED PLAN

SCALE: 1/2" = 1'-0"

1

-

ENLARGED RCP

SCALE: 1/2" = 1'-0"

2

-

REGISTERED

ARCHITECT

STATE OF WASHINGTON

JULIE ANNE MONTGOMERY

8073

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 12: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

TICKETS

TICKETS

2'-4" MIN

DISTANCE TO SIDE WALL

TVM

UNIT

TVM

UNIT

4'-0" OR 8'-0" TYP

REFER TO PLANS

48"

30

"

2'-11 3/8"

VARIES

1'-6

1

/2

"

VA

RIE

S

R

2

'

-

1

1

5

/

8

"

1 1

/4

"

3'-0"

UNIT DIM

SEE DETAIL A

CL TVM UNIT

CL

CL TVM UNIT

5'-7

5

/8

"

VE

RIF

Y

1" MIN CLR

TYP

1" MIN CLR

TYP

1" M

IN

C

LR

TY

P

UN

IT

D

IM

VA

RIE

S

CL

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

08

/0

8/1

9 | 1

1:2

8 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\G

UID

AN

CE

-S

TA

ND

AR

D_

DR

AW

IN

GS

- W

OR

KIN

G\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-A

SD

30

1.D

WG

STD-ASD301

FACILITY ID:

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

1" = 1'-0"

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

TICKET VENDING MACHINE

AND SMART CARD READERS

STD-ASD301

0

SCALE: 1" = 1'-0"

CARD READER MOUNTING DETAIL 1

-

SCALE: 1" = 1'-0"

TVM - SECTION A

- SCALE: 1" = 1'-0"

TVM - ELEVATION B

-

GUD-APP211

GUD-APP212

A

-

DASHED LINE INDICATES FUTURE

MOUNTING PLATE AND CARD

READER SUPPORT

KNOCKOUT SLAB

CONSTRUCTION

JOINT

CONCRETE "FARE PAID ZONE"

FINISH

STRUCTURAL SLAB (REFER TO

STRUCTURAL DRAWINGS)

CONDUIT PER MANUFACTURER'S

SPECIFICATION (REFER TO

SYSTEMS GUIDANCE DRAWING)

EMBEDDED 18" SQ STEEL PLATE

2 1

/2

"

OUTLINE OF EQUIPMENT AND

OPENING CLEARANCE

OUTLINE OF ADA

PARALLEL APPROACH

GASKETED ENCLOSURE, FLUSH

WITH FINISH SURFACE. REFER

TO ELECTRICAL STD. DRAWINGS

OUTLINE OF LEVEL TVM

CONCRETE PEDESTAL BASE

TVM UNIT

PROVIDE COVER PLATE, FLUSH

TO FINISH FLOOR AT FUTURE TVM

LOCATIONS

FLOOR FINISH AS SCHEDULED

GASKETED ENCLOSURE PER

SYSTEM REQUIREMENTS,

CAST INTO CONCRETE BASE

COORDINATE WITH SOUND

TRANSIT SIGNAGE STANDARDS

ADDITIONAL TVM,

WHERE OCCURS

TVM UNIT

1" MIN CLR

TYP

1" M

IN

C

LR

TY

P

1" MIN CLR

TYP

1" M

IN

C

LR

TY

P

FACE OF WALL FINISH, TYP

FINISH FLOOR

WHERE OCCURS

GENERAL NOTES:

1. ALL INSTALLATIONS SHALL COMPLY WITH THE

NATIONAL ELECTRICAL CODE (NEC), CURRENT

EDITION AND THE WASHINGTON STATE ELECTRICAL

CODE.

2. TICKET VENDING MACHINE (TVM), AND FLEXIBLE

CONDUIT SHALL BE COORDINATED W/FINAL

DESIGNERS AND SYSTEMS.

3. REFER TO SYSTEMS DRAWINGS FOR FINAL CONDUIT

LAYOUT AND DIMENSIONS. CONDUITS SHOWN, WHERE

APPLICABLE, ARE PRELIMINARY.

4. THE ORIENTATION AND LOCATION OF JUNCTION

BOXES AND CONDUIT STUB OUTS SHALL BE

CONFIRMED WITH SYSTEMS.

5. CONDUIT SIZES AND BEND RADIUS WITH TVM

MANUFACTURER SHALL BE VERIFIED BY SYSTEM

ENGINEERS.

6. TVM DIMENSIONS ARE BASED ON SCHEIDT &

BACHMANN SPECIFICATION. CONFIRM FINAL TVM

DIMENSIONS WITH SOUND TRANSIT.

SCALE: 1" = 1'-0"

TYPICAL TVM PLAN

B

-

SCALE: 1" = 1'-0"

ENLARGED PLAN - TVM 2

-

0 8/2019 NEW - ARCH DIRECTIVE AND STANDARD DWGS

REGISTERED

ARCHITECT

STATE OF WASHINGTON

JULIE ANNE MONTGOMERY

8073

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 13: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

MANUFACTURER

3'-5"

FEC

FEC

FINISH FLOOR

SEE MOUNTING DETAILS

B/A-01-305 AND C/A-01-305

AS APPLICABLE

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

08

/0

8/1

9 | 1

1:2

7 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\G

UID

AN

CE

-S

TA

ND

AR

D_

DR

AW

IN

GS

- W

OR

KIN

G\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-A

SD

30

5.D

WG

STD-ASD305

FACILITY ID:

CL DOOR & SIGN

6"

CL SIGN

3'-0

"

4'-6

"

FINISH FLOOR

AL

IG

N

VA

RIE

S P

ER

M

FR

RE

CE

SS

P

ER

C

MU

M

OD

UL

E

PARTITION

AS SCHEDULED

VA

RIE

S P

ER

M

FR

FINISHED FLOOR

4'-0

"

FINISH FLOOR

2 1/2"

2 1

/2

"

4'-0

"

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

AS NOTED

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

EQUIPMENT MOUNTING

ELEVATIONS AND DETAILS

STD-ASD305

0

ROUND SST CAP, WELD

AND GROUND SMOOTH

SPEAKER/BEACON MODULE AND

CONNECTION TO POST PER

FIXTURE MFR

FIXTURE PER SCHEDULE, BOX AND

CONNECTION TO POST PER

FIXTURE MFR

HOLES FOR CIRCUIT

METAL PANEL AS SCHEDULED

BEZEL PER FIXTURE MFR

COUNTERSUNK #10 FLATHEAD

TAMPERPROOF SCREWS, TYP OF (6)

BACKER BOX PER FIXTURE MFR

RECESSED EQUIPMENT OR

DEVICE AS SCHEDULED

FINISH WHERE SCHEDULED

INSULATED GROUNDING TYPE

CONDUIT BUSHING WITH KNOCKOUT

CONDUIT AS REQUIRED (DASHED)

WALL ASSEMBLY AS SCHEDULED

FINISH PER FINISH SCHEDULE,

WHERE OCCURS

EQUIPMENT AS SCHEDULED

CMU PARTITION AS SCHEDULED

(OPTION: USE RATED CABINET)

EQUIPMENT AS SCHEDULED

METAL PANEL WITH STIFFENER

OPENING SURROUND

BEZEL PER FIXTURE MFR

COUNTERSUNK #10 FLATHEAD

TAMPERPROOF SCREWS, TYP OF (6)

BACKER BOX PER FIXTURE MFR

UNISTRUT FRAME SUPPORTING

FIXTURE BACKER BOX SECURED TO

CONC SLAB BELOW

INSULATED GROUNDING TYPE

CONDUIT BUSHING WITH KNOCKOUT

CONDUIT AS REQUIRED (DASHED)

COORDINATE SIZE AND

PLACEMENT OF OPENING FOR

EQUIPMENT IN METAL PANEL

FINISH PER FINISH

SCHEDULE, WHERE OCCURS

RECESSED EQUIPMENT OR DEVICE

METAL BLOCKING AS REQUIRED

ROOM IDENTIFICATION SIGN

ALTERNATE LOCATION 1

ROOM IDENTIFICATION SIGN

ALTERNATE LOCATION 2

ACCESS CARD READER,

SEE DOOR SCHEDULE &

SYSTEMS DWGS

ROUND SST CAP, WELD

AND GROUND SMOOTH

FIXTURE PER SCHEDULE, BOX

AND CONNECTION TO POST PER

FIXTURE MFR

HOLES FOR CIRCUIT

3 1/2" DIA SST POST, 11 GA

1/4" SST KNIFE PLATE, TYP OF (4)

HOLES FOR CONDUIT EMBEDS

3/8" X 12" DIA SST BASE PLATE

1/2" DIA WEDGE ANCHOR

FIELD BOLTS, TYP OF (4)

R.O

.

VA

RIE

S

INSULATION WHERE OCCURS

0 8/2019 NEW - ARCH DIRECTIVE AND STANDARD DWGS

PLAN

ELEVATION

PLAN

ELEVATION

1/4" SST KNIFE PLATE, TYP OF (4)

HOLES FOR CONDUIT EMBEDS

3/8" X 12" DIA SST BASE PLATE

1/2" DIA WEDGE ANCHOR

FIELD BOLTS, TYP OF (4)

3 1/2" DIA SST POST, 11 GA

SCALE: 1" = 1'-0"

POST MOUNTED FIXTURE DETAIL 3

- SCALE: 3" = 1'-0"

RECESSED EQPM PLAN DETAIL @ MTL PANEL

4

- SCALE: 1" = 1'-0"

RECESSED EQPM SECTION @ STUD WALL

C

- SCALE: 1" = 1'-0"

TYPICAL MOUNTING HEIGHTS 5

-

SCALE: 1/2" = 1'-0"

TYPICAL SIGNAGE AT DOORWAYS 2

-SCALE: 1" = 1'-0"

RECESSED EQPM SECTION @ CMU WALL

B

-SCALE: 1" = 1'-0"

RECESSED EQPM SECTION

@ METAL PANEL

A

-SCALE: 1" = 1'-0"

POST MOUNTED FIXTURE DETAIL WITH SPEAKER 1

-

REGISTERED

ARCHITECT

STATE OF WASHINGTON

JULIE ANNE MONTGOMERY

8073

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 14: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

FACE OF WALL

3'-0"

8 1/2"

2'-8"

CLR

PLATFORM EDGE

2"

HSS FRAME

6"

EQEQ

CL

CL

CL

CL

STL STRIKE PLATE

ACR - FLUSH MOUNT

TO INFILL PANEL &

CONCEAL CONDUIT

IN FRAME

PERFORATED INFILL

PANELS WITH 1 1/2"

NON-PERF BORDER

CONT ANGLE AROUND

EDGE OF PERFORATED

INFILL PANEL SERVICE

SIDE

SERVICE SIDE

1"

PUBLIC SIDE

2 1/2"

2" 2"

2"

2"

8"

HINGE

1"x1" CONT ANGLE

AROUND METAL

PANELS W/ TAMPER

PROOF FASTENERS

FACE OF WALL

2 1/2"

CONDUIT FOR ELEC AT

STRIKE JAMB

BASE PLATE BELOW, TYP

ELECTRIC LOCK,

COORDINATE W/

STRIKE PLATE

ROUTE FLEX CONDUIT UP TO LATCH THRU

HSS, WHERE OCCURS

DRILLED HOLE FOR CONDUIT, WHERE OCCURS

3/8" BASE PLATE WELDED TO FRAME

J-BOX BELOW BASE PLATE, WHERE OCCURS

EDGE OF PLATFORM

SHIM & GROUT AS REQUIRED

HSS POST

EPOXY ANCHOR

2"x2"x5/16" HSS

(4) 5/8" EPOXY ANCHOR

3/8" STL BASE PLATE WELDED TO POST

2"x2"x5/16" HSS, TYP

STRIKE PLATE

EDGE OF

PLATFORM

NOTE: REFER TO 6/GUD-ATD325

FOR GATE POST BASE DETAILS.

METAL INFILL PANELS

W/ 1 1/2" NON-PERF

BORDER

CL

CL CL

CL CL

CL

CL

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

08

/0

8/1

9 | 1

1:2

5 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\G

UID

AN

CE

-S

TA

ND

AR

D_

DR

AW

IN

GS

- W

OR

KIN

G\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-A

TD

32

5.D

WG

STD-ATD325

FACILITY ID:

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

AS NOTED

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

EXIT STAIR

DETAILS

STD-ATD325

0

HANDRAIL BRACKET @ GUARDRAIL

SCALE: 6"=1'-0"

7

-

NOTE:

WALL BRACKET SHOWN.

VERIFY BRACKET AT

GUARDRAILS WITH DETAILS.

2'-0" MAX.

EQ. EQ.

34

" M

IN

38

" M

AX

1

2

"

M

A

X

1'-0"

1 1

/2

" M

IN

1/8

" T

O F

.O

.

WA

LL

O

R

GU

AR

DR

AIL

R

=

3

"T

Y

P

FINISH FLOOR

4"

3"

MIN

5 1

/2

"

TY

P

3'-6

"

4"

MAX

FINISH FLOOR

1 1/2"

MIN

1

1

/4

"

3/4"

15°

1 1/2" MIN

3'-0

"

3 3/4"

VARIES

SEE PLAN

3'-6

"

3 3/4"

4"

MA

X

OPP

3'-0

"

3'-6

"

3'-0

"

7

-

OPP

7

-

PLATFORM GATE HINGE & JAMB DETAIL

SCALE: 1"=1'-0"

2

-

2

-

0 8/2019 NEW - ARCH DIRECTIVE AND STANDARD DWGS

SECTION

PLAN

PLAN

SECTION

PLAN VIEW

SIDE VIEW END VIEW

ELEVATION ELEVATION

PLAN AT

WALL RETURN

RAILING DOWN

HORIZONTAL

RAILING UP

CONT RAILING RAD

CORNERS, TYP

MITERED CORNERS

WHERE OCCURS

METAL INFILL END,

GRIND SMOOTH

HANDRAIL, VERIFY TYPE W/

DETAIL & SPECIFICATIONS

RAILING WALL BRACKET MAX

SPACING @ 6'-0" O.C. UON. VERIFY

BRACKET TYPE WITH DETAILS

PROVIDE BLOCKING @

STUD WALL CONST.

RAILING WALL BRACKET, TYP

1 1/2" O.D. PAINTED HANDRAIL

SHAPED BRACKET SADDLE WITH

COUNTERSUNK FASTENERS,

PAINT TYP

1/4" PLATE BRACKET WELDED TO

VERTICAL BAR & HANDRAIL

GUARDRAIL VERTICAL AS SCHEDULED

1 1/2" O.D. STEEL

PIPE HANDRAIL

1 1/2" O.D. STEEL POST,

TYP

PLATE AND EMBEDDED

ANCHOR. (SEE

STRUCTURAL DWGS)

1 1/2" O.D. STEEL

PIPE HANDRAIL

1 1/2" O.D. PAINTED

STEEL PIPE, TYP

1 1/2" O.D. PAINTED

STEEL PIPE, TYP

TREAD / LANDING

WELD VERTICAL POST

TO STRINGER

STEEL STRINGER BY

STAIR MFR

1 1/2" O.D. PAINTED STEEL

PIPE GATE FRAME

SELF CLOSING

GATE HINGE

HANDRAIL AS SCHEDULED

CAST METAL WALL BRACKET -

SPACE AS REQ.

3/8" TOGGLE BOLTS @ GWB; 3/8" DIA

BOLTS W/ EXP. BOLT @ CONC, 2 1/4"

MIN EMBED (NOT SHOWN)

METAL BLOCKING

WALL AS SCHEDULED

PLATFORM END GATE ELEVATION

SCALE: 1"=1'-0"

A

-

HANDRAIL TRANSITIONS

SCALE: 1"=1'-0"

1

-

HANDRAIL DETAILS

SCALE: 1"=1'-0"

3

-

GUARDRAIL @ CONCRETE FLOOR SLAB

SCALE: 1"=1'-0"

4

- SCALE: 1 1/2" = 1'-0"

TYPICAL GUARDRAIL @ NON PUBLIC STAIR

5

-

SCALE: 1" = 1'-0"

PLATFORM END GATE POST BASE DETAIL 6

-

HANDRAIL BRACKET @ WALL

SCALE: 6"=1'-0"

8

-

SCALE: 1" = 1'-0"

TYPICAL EXIT STAIR BARRIER GATE9

-

REGISTERED

ARCHITECT

STATE OF WASHINGTON

JULIE ANNE MONTGOMERY

8073

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 15: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

7"

1'-0

"

TY

P

1'-0

"

1'-9 1/4" 8"

4'-0

" A

FF

TYP

3/16"

TYP

3/16"

FIN FLR

LIGHT SWITCH

LOCATED 48" AFF

FRONT WALL

STL BAR

1-1/2" X 1/4" X L

SIDE WALL

SUB-SILL FOR

ELEVATOR DOOR

BY ELEV MFR

3/4" DIA ROD

RUNGS. COAT

WHOLE RUNG

W/ NON-SLIP

COATING, TYP

BENT PLATE

10 X 2-1/2" X 1/4"

1/2" DIA X 2-3/4"

SLEEVE ANCHOR

AS REQD

BENT PLATE

2-1/2" X 6 X 1/4"

2 1

/2

"

MIN

EQ EQ

2"

MIN

7"

EQ

EQ

CL

CL

CL

FLOOR LEVEL TACTILE

SIGN AND SYMBOLS

MOUNTED ON BOTH

JAMBS - SEE ANSI 703.3

ELEVATOR INTERNAL

HALL LANTERN / LOBBY

POSITION INDICATOR

MOUNTED IN JAMB

SST ELEVATOR FRAME

BEYOND

SST ELEVATOR DOOR

SST ELEVATOR FRAME

STAR OF LIFE SIGN /

SYMBOL

1'-6

"

1'-6"

GALV METAL GRATING COVER

FOR SUMP PIT (INSTALL

FLUSH W/ PIT FLOOR)

SEE STRUCTURAL FOR

GRATING SUPPORT

NOTE:

1. SEE ELEVATOR PIT PLANS FOR

LOCATION

2. PROVIDE INDIRECT DRAIN WITH

MINIMUM 50GPM DRAINAGE

CAPACITY TO REMOTE SUMP.

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

08

/0

8/1

9 | 1

1:1

0 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\G

UID

AN

CE

-S

TA

ND

AR

D_

DR

AW

IN

GS

- W

OR

KIN

G\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-A

VD

34

0.D

WG

STD-AVD340

FACILITY ID:

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

AS NOTED

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

ELEVATOR

DETAILS

STD-AVD340

0

0 8/2019 NEW - ARCH DIRECTIVE AND STANDARD DWGS

SECTION ELEVATION

SCALE: 3/4" = 1'-0"

ELEVATOR PIT LADDER1

- SCALE: 3/4" = 1'-0"

ELEVATOR SUMP PIT SECTIONA

- SCALE: 3" = 1'-0"

ELEVATOR FLOOR INDICATORS2

-

REGISTERED

ARCHITECT

STATE OF WASHINGTON

JULIE ANNE MONTGOMERY

8073

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 16: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

EQ EQ

7"

11" 6"

17" - 25" CLR

2'-3"

2'-10"

5"

9"

FIN FLR

10" M

AX

TA-9

TA-6B

TA-6A

TA-1

TA-5

TA-8A

TA-3

TA-4

TA-3

LAV

TA-6C

WC

16"-18"

1'-3"

5'-0"

5'-0

"

1'-0

"

CLEAR AREA

30"x48"

1'-4

" T

YP

1ꞌ-6

" A

CC

WC TA-6

FIN FLR

4'-0

"

TA-8A MH

1'-5

"

MA

X

UR

2'-1

1"

3'-4

"1

'-6

"

3'-4"

3'-6"

4'-6"

2'-1

1"

TA-1

1'-6

"

MIN

1 1

/2

"

TA-12

4'-0

"

TA-11TA-9

TA-1A

1'-6

"

MIN

1 1

/2

"

2'- 6

" A

CC

TA-5

3'-6

"

TA-7

4'- 4

" T

YP

3'-4

" M

AX

B

O

RE

FL

EC

TIV

E

SU

RF

AC

E

TA-4TA-3 TA-3A

3'-6

"

TO

OP

ER

AB

LE

PA

RT

TA-4A

3'-6

"

TA-7A

FIN FLR

3'-6

"

TO

OP

ER

AB

LE

PA

RT

3'-4

" M

AX

B

O

RE

FL

EC

TIV

E

SU

RF

AC

E

4'-0

"

4'-4

" T

YP

2'-6

" A

CC

24

"- 3

6"

1'-0"

1'-0"B.O. GRAB

BAR

B.O. GRAB

BAR

GRAB BAR

CLEARANCE

TA-6A

BACK WALL

TA-6B

SIDE WALL

TA-6C

WC

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

08

/0

8/1

9 | 1

1:2

0 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\G

UID

AN

CE

-S

TA

ND

AR

D_

DR

AW

IN

GS

- W

OR

KIN

G\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-A

ID

37

0.D

WG

STD-AID370

FACILITY ID:

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

AS NOTED

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

TOILET ACCESSORIES

STD-AID370

0

0 8/2019 NEW - ARCH DIRECTIVE AND STANDARD DWGS

TOILET ACCESSORIES LEGEND

ACCESSORY DESCRIPTION COMMENTS

TA-1 TOILET PAPER DISPENSER

TA-1A TOILET PAPER DISPENSERAT PUBLIC RESTROOM, VANDAL RESISTANT

TA-2(NOT USED)

TA-3 SOAP DISPENSER

TA-3A SOAP DISPENSERAT PUBLIC RESTROOM, VANDAL RESISTANT

TA-4 MIRRORS

TA-4A MIRRORSAT PUBLIC RESTROOM, VANDAL RESISTANT

TA-5 SEAT COVER DISPENSER

TA-6 GRAB BARS

TA-7 SURFACE-MOUNTED ELECTRONIC HAND DRYER

TA-7A SEMI RECESSED ELECTRIC HAND DRYERAT PUBLIC RESTROOM, VANDAL RESISTANT

TA-8A CLOTHES HOOKAT PUBLIC RESTROOM, VANDAL RESISTANT

TA-9 SANITARY NAPKIN RECEPTICLE UNIT

TA-10 UNDERSINK ANTI-BURN PROTECTION

TA-11 SURFACE MOUNTED WASTE RECEPTICLE

TA-12 COMBINATION SANITARY NAPKIN/ TAMPON VENDOR

MH COMBINATION UTILITY SHELF/MOP AND BROOM HOLDER

GENERAL NOTES:

1. FIXTURES AND ACCESSORIES ARE GENERIC FOR ALL PROJECTS. REFER TO

PLANS, DETAILS, AND SPECIFICATIONS FOR PROJECT REQUIREMENTS.

2. ACC = ACCESSIBLE

3. FOIC, NOTED AS APPLICABLE

4. ALL PUBLIC RESTROOM ACCESSORIES TO HAVE SST FINISH.

SCALE: 1/2" = 1'-0"

PLAN

SCALE: 1/4" = 1'-0"

TYPICAL MOUNTING HEIGHTS

SCALE: 1/2" = 1'-0"

TYPICAL ELEVATION A

- SCALE: 1/2" = 1'-0"

TYPICAL ELEVATION B

-

CL

2'-0"

SCALE: 1/2" = 1'-0"

TYPICAL ELEVATION C

- SCALE: 1/2" = 1'-0"

TYPICAL DOOR ELEVATION D

-

A

D

C

B

--

REGISTERED

ARCHITECT

STATE OF WASHINGTON

JULIE ANNE MONTGOMERY

8073

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 17: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

6'-4"

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

08

/0

8/1

9 | 1

1:1

8 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\G

UID

AN

CE

-S

TA

ND

AR

D_

DR

AW

IN

GS

- W

OR

KIN

G\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-A

ND

50

0.D

WG

STD-AND500

FACILITY ID:

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

NTS

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

SIGNAGE TYPES

STD-AND500

0

PRIMARY LINK

A1

NO VERTICAL POST- ATTACH

DIRECTLY TO CW MULLION

A4

9'-0

"

17

'-0

"

3'-7"

DIM POINT

MAJOR FASCIAA6

MAJOR PENDANT

A7

8'-0" MIN AFF,

9'-0" AFF WITH

CIRCULATION

BELOW

8'-2"

1'-4

"

VA

RIE

S

6'-0"

DIM POINT

MINOR FASCIAA8

MINOR PENDANTA9

6'-4"

8'-0" MIN AFF,

9'-0" AFF WITH

CIRCULATION

BELOW

1'-2

"

VA

RIE

S

4'-9"

DIM POINT

PENDANT DOUBLE SIDED

B2

FASCIA MOUNT

B3

PENDANT SINGLE SIDEDB1

8'-0" MIN AFF,

9'-0" AFF WITH

CIRCULATION

BELOW

1'-2

"

4'-9"

VA

RIE

S

OCS POLE

B4

POLE

B5

DIM POINT

9'-0" MIN AFF

6'-4"

1'-2

"

SOUND TRANSIT STATION CODESTA =

SIGN TYPEF2.A =

INDICATION OF PRIMARY SIGN FACE=

INDICATION OF SECONDARY SIGN FACE

=

MOUNTING DETAIL1/L200-AND901 =

SIGNAGE TAG =

UNIQUE LOCATION #XXX =

STA F2.A XXX 01/L200-AND101

C1.A STATION ENTRANCE (4 PANELS)

C6.D BICYCLE PARKING (1 PANEL)

C6.E DIRECTIONAL (1 PANEL)

C6.F BUS SCHEDULE (1 PANEL)

C1.B CENTER PLATFORM (4 PANELS)

C1.C 1/4 AND 3/4 PLATFORM (2 PANELS)

C6 FLEXIBLE CONTENT (1 PANEL)

1"

TYP

3'-1

0"

1'-7"

TYP

2'-0" AFF

DIM POINT

2'-0

"3

'-1

0"

3'-9"

1/4 AND 3/4 PLATFORMC2.C

DOUBLE SIDED; 1/4 AND 3/4

PLATFORM

C3.C

AS

N

OT

ED

6'-4"

D1

PENDANT SINGLE SIDED (DEPTH = 1'-2")

D2

PENDANT DOUBLE SIDED (DEPTH = 1'-2")

D3

FASCIA MOUNT (DEPTH = 1'-2")

D5

PENDANT DOUBLE SIDED (DEPTH = 1'-7")

D4

PENDANT SINGLE SIDED (DEPTH = 1'-7")

AT FASCIA: 8'-0" MIN

AFF, 9'-0" AFF WITH

CIRCULATION BELOW

AT PENDANTS: 9'-0" MIN

AFF

DIM POINT

VA

RIE

S

4'-9"

MEDIUMD14

4'-0

"2

'-4

"

1'-5"

ST PARATRANSITE3

10

'-2

"

7'-9

"

1'-10 3/8"

9'-0" MIN AFF

DIM POINT

1'-0

"

1'-0 1/16"

F1.D

F1.J ELEVATOR

BICYCLE STORAGE

F1.K EMERGENCY PHONE

INFORMATION

F1.B

TICKETS & ORCA

F1.C

1'-0

"

F2.K EMERGENCY PHONE

TICKETS & ORCAF2.C

F2.J ACCESSIBLE ELEVATOR

DIM POINT

8'-0" MIN AFF,

9'-0" WITH

CIRCULATION

BELOW

1'-0

"

8"

TACTILE IDF3.A

FACILITY HOURS STATIONF4.A

FACILITY HOURS GARAGEF4.B

4'-0" AFF

DIM POINT

2'-6" AFF

DIM POINT

1'-6"

1'-0

"

BIKE LOCKERSF5

9'-0" AFF

DIM POINT

10'-0"

1'-1

"

ENTRY ID

G1

DANGER NO TRESPASSINGR1.I

AUTHORIZED PERSONNEL ONLYR1.J

RESERVED ACCESSIBLE PARKINGR1.F

EMERGENCY EXIT ONLYR1.K

VAN ACCESSIBLER1.G

ELECTRIC VEHICLE PARKINGR1.L

15 MINUTE PARKINGR1.B

24 HOUR PARKINGR1.C

RESERVED SECURITY PARKINGR1.D

RESERVED SERVICE PARKINGR1.E

NO PARKINGR1.A

1'-6

"

1'-0"

4'-0" AFF

DIM POINT

ESCALATOR SAFETY

RULES

R2.E

1'-0

"

8"

4'-0" AFF

DIM POINT

2

'

-

0

"

2

'

-

0

"

5'-0

"

CAUTION LOOK BOTH WAYS

R3

PARKING

R4

4'-0

"3

'-0

"

2'-0"

FARE ZONE PENDANT DOUBLE SIDED

R6

FARE ZONE PENDANT SINGLE SIDED

R5

9'-0" MIN AFF

DIM POINT

6'-4"

1'-2

"

VA

RIE

S

4'-9"

2 CAR TRAIN STOPPING MARKER

X1.A

4 CAR TRAIN STOPPING MARKER

X1.B

1'-0

"7

'-0

"

1'-0"

ORCA READER

R7

5'-2

"

SOFFIT

WHERE

OCCURS

SOFFIT

WHERE

OCCURS

SOFFIT

WHERE

OCCURS

POST

WHERE

OCCURS

R1.G WHERE

INDICATED IN PLANS

0 8/2019 NEW - ARCH DIRECTIVE AND STANDARD DWGS

GENERAL NOTES:

1. ALL SIGNAGE, INCLUDING SIGNAGE PANELS, PENDANTS, POLES, INTEGRAL MOUNTING

BRACKETS, DECALS, AND FASTENERS SHALL BE PROVIDED AND INSTALLED BY THE

SIGNAGE INSTALLER UNDER A SEPARATE CONTRACT UNLESS OTHERWISE NOTED.

2. CONTRACTOR SHALL PROVIDE ANCHOR BOLTS AND BLOCKING AND OR ATTACHMENT

SUPPORTS FOR SIGNAGE AT THE LOCATIONS INDICATED IN THE SIGNAGE PLANS,

SIGNAGE DETAILS AND OTHERWISE NOTED IN THE GENERAL CONTRACT DRAWINGS.

3. CODE RELATED "J" SERIES SIGNAGE SHALL BE PROVIDED BY THE CIVIL CONTRACTOR.

4. WHERE PENDANT LENGTH EXCEEDS THE MAXIMUM ALLOWABLE LOADING FOR

ALUMINUM, SIGNAGE CONTRACTOR SHALL PROVIDE STEEL PENDANT UNDER THE

SIGNAGE CONTRACT.

5. SEE STATION SPECIFIC STRUCTURAL DRAWINGS FOR SIGN FOUNDATION DETAILS.

6. COORDINATE WITH CIVIL DRAWINGS FOR SIGN LOCATIONS OUTSIDE OF STATIONS.

7. COORDINATE LOCATION AND WEIGHTS OF SIGNS WITH SOUND TRANSIT CAPITAL

SIGNAGE.

STATION ID

STATION ID STATION ID PLATFORM ID PLATFORM ID

CUSTOMER INFORMATION

CUSTOMER INFORMATION

DIRECTIONAL

DIRECTIONAL

BUS - E3

REGULATORY - MAJOR

POST OR WALL

GUIDE

FACILITY WALLFACILITY WALL

FACILITY FASCIA

FACILITY POST

OR WALL

REGULATORY - MAJOR

WALL

REGULATORY

POST OR RAILING

REGULATORYREGULATORY

REGULATORY OPERATIONS

LEGEND:

REGISTERED

ARCHITECT

STATE OF WASHINGTON

JULIE ANNE MONTGOMERY

8073

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 18: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

1'-0"

2"

1'-6

"4

'-0

" A

BO

VE

FIN

IS

HE

D G

RA

DE

SIG

NA

GE

H

EIG

HT

PE

R S

IG

N T

YP

E

DIM PT PER SIGN TYPE

SA

ME

D

IM

A

S S

IG

N

SA

ME

D

IM

A

S S

IG

N

9'-0

"

MIN

AF

F

VA

RIE

S

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

AS NOTED

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

SIGNAGE MOUNTING

DETAILS

STD-AND501

0

CL HSS AND SIGN

~20"

VA

RIE

S

CL OF SIGN

6"ANGLE OF CANOPY ABOVE

WHERE OCCURS

TRANSFORMER HOUSING

JUNCTION BOX

HSS CANOPY STRUCTURE

STEEL PLATE

MOUNTING ARM BY MFR

SIGNAGE

LIGHTING

CUSTOMER SIGNAGE, NIC

SOFFIT STRUCTURE

SOFFIT FINISH

JUNCTION BOX

TRANSFORMER HOUSING

SIGNAGE LIGHTING

CUSTOMER SIGNAGE, NIC

SIGNAGE MOUNTING

PLATE, 11 GA

SIGN TYPE R1-I SIGN AND

ADJUSTABLE MOUNTING

HARDWARE BY SIGNAGE

CONTRACTOR, NIC

STEEL STANCHION SEE

STRUCT, TYP

FINISH AS SCHEDULED

BACKING PLATE, 11 GA STL

ROUNDHEAD #5 X 3/4" LONG

BOLT FOR SIGN ATTACHMENT

SIGN (SHOWN DASHED) MOUNTED DIRECTLY

TO ARCHITECTURAL FINISH BY SIGNAGE

CONTRACTOR, NIC

SCREEN PANEL

BACKING PLATE, ADHESIVE

MOUNTED 11 GA STL

ISOLATION BETWEEN

DISSIMILAR METALS

ROUNDHEAD #5 X 3/4" LONG

BOLT FOR SIGN ATTACHMENT

ISOLATION BETWEEN

DISSIMILAR METALS

SIGN (SHOWN DASHED) MOUNTED

DIRECTLY TO ARCHITECTURAL

FINISH BY SIGNAGE

CONTRACTOR, NIC

MOUNT SIGN TO

STRUCTURAL MEMBER,

PROVIDE INSULATION PAD

AT DISSIMILAR MATERIALS

MOUNTING PLATE AND

ANCHORS, AND SIGN

ASSEMBLY BY SIGNAGE

CONTRACTOR, NIC

FINISH AS SCHEDULED

SIGN, MOUNTING BRACKETS

AND FASTENERS (SHOWN - BY

SIGNAGE CONTRACTOR, NIC)

BACKING PLATE,

5" WIDE X 10" TALL, 11 GA

11 GA STEEL BACKING FOR PANELS

WHERE SIGNAGE OCCURS

METAL PANEL

STRUCT PER STATION DWGS

HSS 6" X 6" OR STRUCTURAL "T" PER

STATION DRAWINGS

CEILING WHERE OCCURS

ISOLATION PAD

6" X 6" ALUM MOUNTING PLATE,

PENDANT ARM AND SIGN BY

SIGNAGE CONTRACTOR, NIC

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

08

/0

8/1

9 | 1

1:1

9 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\G

UID

AN

CE

-S

TA

ND

AR

D_

DR

AW

IN

GS

- W

OR

KIN

G\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-A

ND

50

1.D

WG

STD-AND501

FACILITY ID:

0 8/2019 NEW - ARCH DIRECTIVE AND STANDARD DWGS

NOTE:

SEE DETAIL 7/GUD-AND502 FOR STACKED SIGNS

GENERAL NOTE:

1. DETAILS SHOWN INDICATE PROTOTYPICAL MOUNTING DETAILS

ONLY. SPECIFIC STATION SIGNAGE MOUNTING REQUIREMENTS

MAY VARY.

SCALE: 1 1/2" = 1'-0"

SIGNAGE LIGHTING - CANOPY MOUNT1

- SCALE: 1 1/2" = 1'-0"

SIGNAGE LIGHTING - SOFFIT MOUNT2

- SCALE: 1" = 1'-0"

SIGNAGE MOUNTING - INTER-TRACK FENCE3

-

SCALE: 3" = 1'-0"

SIGNAGE MOUNTING - FASCIA 4

- SCALE: 3/4" = 1'-0"

SIGNAGE MOUNTING - AT SCREEN PANELS 5

- SCALE: 3" = 1'-0"

SIGNAGE MOUNTING - PENDANT 6

-

SCALE: 3" = 1'-0"

SIGNAGE MOUNTING - BLADE7

- SCALE: 3" = 1'-0"

SIGNAGE MOUNTING - AT METAL PANEL8

- SCALE: 3" = 1'-0"

PENDANT MOUNTING PLATE9

-

REGISTERED

ARCHITECT

STATE OF WASHINGTON

JULIE ANNE MONTGOMERY

8073

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g

Page 19: Architectual Standard Drawings · 2019-11-20 · std-app270 1 information kiosk at center platform std-app271 1 information kiosk at side platform std-add280 0 windscreens at center

CL

No. DATE DSN CHK APP REVISION

SUBMITTED BY: DATE: REVIEWED BY: DATE: DATE:

CONTRACT No.:

FILENAME:

SCALE: DRAWING No.:

SHEET No.: REV:

LIN

E IS

1

" A

T

FU

LL

S

CA

LE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

APPROVED BY:

08

/0

8/1

9 | 1

1:1

7 A

M | G

AL

LA

GH

ER

C

T:\_

HQ

_IN

TE

RN

AL

\E

XH

IB

IT

S\G

UID

AN

CE

-S

TA

ND

AR

D_

DR

AW

IN

GS

- W

OR

KIN

G\A

RC

H-M

EC

H\S

TA

ND

AR

D\D

RA

WIN

GS

\S

TD

-A

ND

50

2.D

WG

STD-AND502

FACILITY ID:

4'-9"

9'-0

" A

FF

M

IN

3/16

8"

4 1

/2

"

7"

1/4

CL

4'-0

" A

BO

VE

FIN

IS

HE

D G

RA

DE

1 1/4"

1'-0"

CL

1'-6

"2

"

ALIGN

1/4

9'-0" AFF

CL

2"

MIN

1'-2

"

1'-4

"6

"

9 1/2" 4'-9" 2'-1 1/2"

3/16

3/16

2" 1'-1" 6"

8"

8'-0" AFF

2'-0"

7"

8"

3/16

2 SIDES

6"

8"

6'-4"

1'-2

"

2"

1'-2

"

1'-4

"

9'-0" AFF

MIN

J. PEREZ

C. GALLAGHER

D. POWELL

J. MONTGOMERY

AS NOTED

8/2019

SOUND TRANSIT

STANDARD DRAWING

ARCHITECTURAL

SIGNAGE MOUNTING

DETAILS

STD-AND502

0

PENDANT - CANOPY PIPE

SCALE: 3"=1'-0"

2

-

POLE MOUNTING BRACKET

SCALE: 3"=1'-0"

4

-

FASCIA SIGN MOUNTING BRACKET

SCALE: 3"=1'-0"

6

-

SIGNAGE MOUNTING - STACKED SIGNS

SCALE: 1/2"=1'-0"

7

-

3/16" THK BENT

STL PLATE

WELDED TO

8"Ø BEAM

PIPE PER STRUCT

SIGNAGE (DASHED) BY

SIGNAGE CONTRACTOR, NIC

SIGN, MOUNTING PLATE,

AND FASTENERS BY

SIGNAGE CONTRACTOR, NIC

3/16" THK BENT

STL PLATE

WELDED TO

8"Ø BEAM

2A

-

2B

-

SIGN TYPE R1.IBY

SIGNAGE CONTRACTOR, NIC

TS 2X2X1/4 POLE, 3/16" STL PLT

END CAP, 7X7X1/2" STL BASE

PLT SECURED TO CONC WITH

(4) 5/8Ø ADHESIVE ANCHOR W/

6" MIN EMBEDMENT, PAINT

CONCRETE SLAB

HSS 6X6X1/4" ARM

3/16" THK END CAP

ALIGN ENDS, AND W/

SIGN D2 AND VMS AT

PLATFORM CANOPY

SIGNAGE (DASHED) BY

SIGNAGE CONTRACTOR, NIC

LIGHT POLE

1/4" STL PLT MOUNTING

BRACKET

(4) 1/2"Ø COUNTER-SUNK

TAMPER-RESISTANT

FASTENERS

1/4" STL STIFFENER

PLATE

4

-

(4) 1/2"Ø COUNTER-SUNK TAMPER

RESISTANT FASTENERS, TYP EACH SIDE

1/4" THK STL MOUNTING RACKET

SIGNAGE (DASHED) BY

SIGNAGE CONTRACTOR, NIC

LIGHT POLE

1/4" THK STL STIFFENER PLATE1/4" THK STL STIFFENER PLATE

ISOLATION MATERIAL

BOTH SIDES

HSS ARM

ABOVE

LIGHT POLE

SIGNAGE BY SIGNAGE

CONTRACTOR, NIC

6

-

1/4" THK SST

MOUNTING

BRACKET WELDED TO

3/16" STL SIGNAGE

MOUNTING PLATE

1/4" THK SST

MOUNTING BRACKET

WELDED TO 3/16" STL

SIGNAGE MOUNTING

PLATE

ALUM LIGHT POLE

ISOLATION MATERIAL

(4) 1/2"Ø COUNTER-SUNK

TAMPER RESISTANT

FASTENERS, TYP, EACH

SIDE

SIGNAGE BY SIGNAGE

CONTRACTOR, NIC

STEEL BEAM

7A

-

SIGNAGE BY

SIGNAGE

CONTRACTOR,

NIC

0 8/2019 NEW - ARCH DIRECTIVE AND STANDARD DWGS

A-SECTION B-ELEVATION

A-SIDE B-ELEVATION

GENERAL NOTE:

1. DETAILS SHOWN INDICATE PROTOTYPICAL MOUNTING DETAILS

ONLY. SPECIFIC STATION SIGNAGE MOUNTING REQUIREMENTS

MAY VARY.

CL

SCALE: 1" = 1'-0"

PENDANT - CANOPY PIPE1

- SCALE: 1" = 1'-0"

SIGN TYPE R1.I -

SLAB-MOUNTED POST-SECTIONA

-

SCALE: 1" = 1'-0"

LIGHT POLE SIGNAGE ARM3

-

SCALE: 1" = 1'-0"

LIGHT POLE - FASCIA MOUNTING SIGN5

-

REGISTERED

ARCHITECT

STATE OF WASHINGTON

JULIE ANNE MONTGOMERY

8073

unco

ntro

lled

docu

men

t fro

m so

undt

rans

it.or

g