+ All Categories
Home > Documents > Architecture and commissioning of the TCV distributed feedback plasma control system

Architecture and commissioning of the TCV distributed feedback plasma control system

Date post: 31-Jan-2016
Category:
Upload: alamea
View: 34 times
Download: 2 times
Share this document with a friend
Description:
Architecture and commissioning of the TCV distributed feedback plasma control system. J.I.Paley , B.P.Duval , S.Coda , J- M.Moret , F.Felici and the TCV Team. - PowerPoint PPT Presentation
Popular Tags:
3
Ecole Polytechnique Fédérale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas, Association Euratom-Confédération Suisse, CH-1015 Lausanne, Switzerland
Transcript
Page 1: Architecture and commissioning of the TCV distributed feedback plasma control system

Ecole Polytechnique Fédérale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas, Association Euratom-Confédération Suisse, CH-1015 Lausanne, Switzerland

Page 2: Architecture and commissioning of the TCV distributed feedback plasma control system

Upgrading our linear, PID coil current controller› Limited in the number of inputs/outputs› Unable to use the TCV ECRH system in feedback› Unable to add further diagnostic signals

Wanted to include the full TCV actuator set including› Coil currents› Gas valves› ECRH systems› Diagnostic systems

Using real time signals from many more diagnostics› Soft x-ray› Diamagnetic › Photodiodes› And more

A large expansion in the number of inputs and outputs was required

The new controller uses acquisition modules linked to PCs in a modular real time network.

Auto code generation (Simulink)

Some of the TCV actuators

Page 3: Architecture and commissioning of the TCV distributed feedback plasma control system

Analogue IO: 384 inputs, 144 outputs Control rates 10 – 100 kHz. Several successful MHD instability and

profile control experiments already carried out.

Including full control of the TCV plasma discharge….

Come to my poster to learn more!


Recommended