PMC LIGHTING | 100 GILBANE STREET, WARWICK, RI | (P) 401-738-7266 | (F) 401-738-0618 | WWW.PMCLIGHTING.COMPMC LIGHTING | 100 GILBANE STREET, WARWICK, RI, 02886 | (P) 401-738-7266 | (F) 401-738-0618 | WWW.PMCLIGHTING.COM
6' FIXTURE W/(3) 22" LED BOARD:
FIXTURE/TYPE(S): PROJECT:
LUMENS IND/DIRCOLOR TEMP
FINISH
VOLTAGE
OPTIONS
INDIRECT OUTPUT LEVELS:035 – 350LM/FT, 2.0W/FT055 – 550LM/FT, 2.9W/FT080 – 800LM/FT, 4.6W/FT100 – 1000LM/FT, 6.0W/FT120 – 1200LM/FT, 7.5W/FT145 – 1450LM/FT, 9.4W/FT170 – 1700LM/FT, 11.3W.FT*220 – 2200LM/FT, 16.3W/FT*
DIRECT OUTPUT LEVELS:035 – 350LM/FT, 2.0W/FT055 – 550LM/FT, 2.9W/FT080 – 800LM/FT, 4.6W/FT100 – 1000LM/FT, 6.0W/FT120 – 1200LM/FT, 7.5W/FT145 – 1450LM/FT, 9.4W/FT170 – 1700LM/FT, 11.3W.FT*220 – 2200LM/FT, 16.3W/FT*
Construction: Welded Extruded Aluminum housing. Internal components punched and dieformed from cold rolled steel.Finish: Polyester powder coated white. Internal components are finished in high glosswhite (Min. Reflectance Factor = 90%). Consult Factory for custom finishes.Dimming: Fixtures supplied with 0-10V dimming down to 1% as standard. Other Dimmingoption are available (Consult Factory).Listing: Fixtures are cETLus listed for Damp Location.
27K - 2700K WARM WHITE LED30K - 3000K WARM WHITE LED35K - 3500K NATURAL WHITE LED40K - 4000K COOL WHITE LED50K - 5000K ULTRA COOL WHITE LED30KS - 3000K BIOS® STATIC35KS - 3500K BIOS® STATIC40KS - 4000K BIOS® STATIC30KD - 3000-2700K BIOS® DYNAMIC35KD - 3500-3000K BIOS® DYNAMIC40KD - 4000-3500K BIOS® DYNAMIC
P - PENDANT / CANOPY (24" STANDARD)SP - SWIVEL PENDANT / CANOPY (45° / 24" STANDARD)AC - ADJUSTABLE AIRCRAFT CABLE (48" STANDARD)S - SURFACET - STANDARD T-BAR CEILINGFL - FLANGED FOR PLASTER OR DRY-WALL CEILINGSTRM - FLANGED FOR TRIMLESS MUD-IN APPLICATIONS
†LAYOUTS OF DIFFERENT CONFIGURATIONS REQUIRE PMC ENGINEERING DRAWINGS TO DETERMINE EXACTCONFIGURATIONS PRIOR TO QUOTATION.†SEE PAGE 2 FOR STANDARD ARCX BLOX SIZES AVAILABLE, AND THE LUMEN DERATING CHART BY COLOR TEMP ANDCRI
FEATURES:
SPECS:
Marrying shape and style with versatility and efficiency. ArcX modules allowconstruction of a wide variety of system contours and shapes making each lightingapplication truly unique.
OUTPUT TYPE FINISH VOLTAGEMOUNTING OPTIONS
OUTPUT TYPE
D - DIRECTI - INDIRECTDI - DIRECT/INDIRECT
LUMENS IND/DIR
WHT - WHITE POWDER COATBLK - BLACK POWDER COATSLV - SILVER POWDER COATCA - CUSTOM COLORS (CONSULT FACTORY)
UNV - UNIVERSAL (120/277V)
MOUNTING
GLR - IN LINE FUSINGEM - EMERGENCY DRIVER (CONSULT FACTORY)90C - 90CRI LED BOARDS
Specifications and Dimensions are subject to change without notice.
ArcX SeriesHigh Efficiency LED
Direct/Indirect, Direct or Indirect • Recessed, Surface or Suspended
COLOR TEMP+
DIFFUSER
DIFFUSER
FWOA - FROSTED WHITE ACRYLIC LENS - LAY-INFPC - FROSTED POLYCARBONATE LENS - LAY-INBWW- WIDE BAT WING OPTICAL LENS**
SIZE CODE†SERIES
ARCX UNV/
ArcX-004
ARCX is available in a wide variety of diameters in full rings (360°), radius(180°, 90°, 45°) and angle sectional curves, and linear lengths (up to 8') tohelp you design the perfect shape layout.
**BWW (WIDE BAT WING OPTIC) AVAILABLE ONLY ON INDIRECTSIDE AND ONLY ON DIAMETERS OF 6' OR GREATER
*NOT AVAILABLE IN BIOS
+SEE FOLLOWING PAGES FOR MORE INFORMATION ONTHIS OPTION
PMC LIGHTING | 100 GILBANE STREET, WARWICK, RI, 02886 | (P) 401-738-7266 | (F) 401-738-0618 | WWW.PMCLIGHTING.COM
ArcX Series
ArcX size codes are based on nominal radius or nominal diameter followed by a letteror number indicating the extent of the sweep of the radius. When the fixture sizeallows, the "sweep" designation is called out as a letter indicating a full diameter (D),a 180˚ sweep (H), a 90˚ sweep (Q), a 45˚ sweep (E). All other sweep designationsare called out in degrees followed by the letter "A" indicating an angle such as 15˚(15A). Custom sized fixture may require custom nomenclature.
Not all radius fixtures can be constructed to specific angles without the introductionof unlit area in the fixture as dictated by the layout of LED boards. PMC uses LEDboards of varying sizes (5.5", 11" and 22" lengths) depending on fixture radius andlayout required for proper driver loading. This insures even illumination throughoutan assembled pattern regardless of fixture sizes required to build the specifiedpattern. Generally any unlit area would be limited to 5.5" or less. Unless otherwiserequested, as standard practice, fixture angles or sweep would be lowered whereverpossible to eliminate any unlit area on the direct side lens.
SIZE CODE NOMENCLATURE NOTES
ArcX BloX ARE STANDARDIZED SEGMENTS OF PMC LIGHTINGS PREMIERArcX LINE OF EXTRUDED ALUMINUM CURVED LED LUMINAIRE THAT CAN BECOMBINED TOGETHER INTO SHAPES ONLY GOVERNED BY THE DESIGNER'SIMAGINATION.
SIZES BELOW MAY BE CONSTRUCTED FROM MULTIPLE SEGMENTS OFFIXTURE TO BUILD THE SIZE SHOWN.
2D OD (Outside Diameter) = 2' 10-1/2" 4D OD (Outside Diameter) = 4' 1-3/4"5D OD (Outside Diameter) = 5' 2-1/2"6D OD (Outside Diameter) = 6' 3-3/4" 8D OD (Outside Diameter) = 7' 11-3/4" 10D OD (Outside Diameter) = 10' 6-1/4" 12D OD (Outside Diameter) = 13' 0-3/4"
2H OR (Outside Radius) = l' 5-1/4" 4H OR (Outside Radius) = 2' 0-7/8"5H OR (Outside Radius) = 2' 7-1/4"6H OR (Outside Radius) = 3' 1-7/8" 8H OR (Outside Radius) = 3' 11-7/8" 10H OR (Outside Radius) = 5' 3-1/8" 12H OR (Outside Radius) = 6' 6-3/8"
SIZE CODE
SIZE CODE
Suspended / Surface For FL and T mounting - add l" flanges to both sides
OR and OD refer to radius at fixture wall anddoes not include flanges
ARCX BLOX
2Q OR (Outside Radius) = l' 5-1/4"4Q OR (Outside Radius) = 2' 0-7/8"5Q OR (Outside Radius) = 2' 7-1/4"6Q OR (Outside Radius) = 3' 1-7/8" 8Q OR (Outside Radius) = 3' 11-7/8" 10Q OR (Outside Radius) = 5' 3-1/8" 12Q OR (Outside Radius) = 6' 6-3/8"
SIZE CODE
10E OR (Outside Radius) = 5' 3-1/8"12E OR (Outside Radius) = 6' 6-3/8"
SIZE CODE
2L L (Length) = 22.50" 3L L (Length) = 33.50" 4L L (Length) = 44.50" 5L L (Length) = 55.75" 6L L (Length) = 66.75" 7L L (Length) = 78.00" 8L L (Length) = 89.00"
SIZE CODE
ArcX-004
LUMEN DERATING CHART BYCOLOR TEMP AND CRI
DIRECT/INDIRECT DIRECT OR INDIRECT
PMC LIGHTING | 100 GILBANE STREET, WARWICK, RI, 02886 | (P) 401-738-7266 | (F) 401-738-0618 | WWW.PMCLIGHTING.COM
BIOS Illuminated®BIOS SkyBlue® lighting solutions contribute to satisfying Circadian Lighting Design Feature 54 under WELLBuilding Standard v1 and Feature L03 under the WELL Building Standard v2. BIOS SkyBlue also meets otherfeatures within the WELL Light Concept, including color quality with 83+ CRI and R9 values at 90, visual comfortmetrics, and higher m/p ratios than traditional LED lighting.
STATIC LIGHT ENGINE – Option Codes 30KS, 35KS, 40KSBIOS SkyBlue Static Spectrum lighting solutions support proper daytime circadian stimulus, communicatingdirectly with human circadian biology through a non-visual photo receptor in the eye. With SkyBlue, there is noneed for color tuning, color temperature adjustments or significantly increasing light levels. Consider the StaticSpectrum Light Engine when the fixtures will illuminate spaces occupied primarily during the daytime hours.
DYNAMIC LIGHT ENGINE – Option Codes 30KD, 35KD, 40KDBIOS SkyBlue Dynamic Spectrum lighting solutions provide full daytime circadian stimulus, communicating directlywith human circadian biology through a non-visual photo receptor in the eye. With SkyBlue, there is no need forcolor tuning, color temperature adjustments, or extra illumination. The SkyBlue Dynamic Light Engineautomatically calibrates the light level, reducing melanopic lux while keeping photopic lux at a constant level whenused in conjunction with proper dimming controls. Consider the Dynamic Spectrum Light Engine when the fixtureswill illuminate spaces occupied during both daytime and nighttime hours.
ArcX Series
ArcX-004
PMC LIGHTING | 100 GILBANE STREET, WARWICK, RI, 02886 | (P) 401-738-7266 | (F) 401-738-0618 | WWW.PMCLIGHTING.COM
ArcX Series
PHOTOMETRIC DATA FOR ARCX: BEING A CURVED FIXTURE OF MANYPOSSIBLE RADII AND ANGLES OF SWEEP, ARCX PHOTOMETRIC DATA AND.IES FILES ARE SUPPLIED IN SHORT 1 FOOT LONG STRAIGHT SEGMENTSTHAT CAN BE LAID OUT IN YOUR ANALYSIS SOFTWARE TO APPROXIMATETHE CURVE AND SIZE OF THE ARCX FIXTURE IN YOUR PARTICULAR DESIGN.THE DATA SHOWN BELOW IS BASED ON THESE 1 FOOT LONG SEGMENTS ANDDO NOT DEPICT ANY ACTUAL ARCX FIXTURE CONFIGURATION AS FAR ASTOTAL LUMEN OUTPUT, TOTAL WATTAGE, LUMINOUS SIZE, SPACINGCRITERIA, ETC. ARE CONCERNED. LUMINAIRE EFFICIENCY, LUMENS PERFOOT, WATTAGE PER FOOT AND LIGHT OUTPUT DISTRIBUTIONS AREACCURATE FOR THE 1 FOOT LENGTH AND ARE RELIABLE APPROXIMATIONSOF HOW A 1 FOOT LONG CURVED SECTION OF ARCX WILL PERFORM.
CONSULT PMC LIGHTING FOR PHOTOMETRIC CONFIGURATIONS NOT SHOWN
ArcX-004