20032_YHSheet No.:
Scale:Status:
Plot Date:
Project No:
Drawing Title:
Project Name
Client
YARROWITCH HALL
The builder shall check and verify all dimensions and levels on site.All errors and omissions to be verified with the Designer before commencment on site.
Do not scale the drawings.Drawings shall not be used for construction purposes until issued for construction.
REV DATE AMENDMENT
15/4/20
/Volumes/Data/01 PROJECTS/01_CURRENT/20032 WALCHA COMMUNITY PROJECTS/YARROWITCH/20032_YARRROW.pln
1:1 @ A1PRELIMINARY
COVER SHEET
All boundary locations and levels to be confirmed by a registered surveyor.All underground service location's to be confirmed.
Obtain and confirm all service connection approvals andrequirements before commencing onsite.
92 UPPER YARROWITCH RIVER ROADYARROWITCHNSW 2354
WALCHA SHIRE COUNCILD&CP R O J E C T Sb u i l d i n g d e s i g nd r a f t i n g s e r v i c e
www.d-cprojects.com.au
0 4 2 4 2 0 9 4 0 8
DT
WD110 30 40 50 100 15020 length in millimeters at full size 200
ARTIST IMPRESSION FROM SITE ACCESSSCALE 1:1000@A1
ARTIST IMPRESSION FROM EASTERN CORNERSCALE 1:1000@A1
DEVELOPMENT NOTESALL BUILDING WORK SHALL BE CARRIED OUTIN ACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA.PROVIDE DOWN PIPES IN ACCORDANCE WITH THE BUILDINGCODE OF AUSTRALIA & AS2180 METAL RAINWATER GOODS.PROVIDE WATERPROOFING SYSTEM TO ALL WET AREASIN ACCORDANCE WITH PART F1-7 OF THE BUILDING CODE.PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS3660.1PROVIDE TIE DOWN AND BRACING IN ACCORDANCE WITHAS1684.2 AND STRUCTURAL ENGINEERS RECOMMENDATIONSBUILDER TO ENSURE A SMOKE DETECTION SYSTEMIS INSTALLED IN ACCORDANCE WITH AS2441
ISSUED FOR CLIENT REVIEW & SIGNOFF01 31/03/20 SB
PROVIDE ACCESSIBLE SIGNAGE IN ACCORDANCE WITH AS1428.1FIRE HOSE REELS TO BE INSTALLED IN ACCORDANCE WITH AS2441INSULATION MUST BE INSTALLED IN ACCORDANCE WITHSECTION J1.5 &J1.6 &J1.3 OF THE BUILDING CODE.ALL LEVELS ARE INDICATIVE AND SHOULD BE CONFIRMED.ALL RAMPS/STAIRS TO BE INSTALLED IN ACCORDANCE WITHAS1428.1.AND HAS SLIP RESISTANT SURFACES IN ACCORDANCE WITHTABLE D2.14 OF THE BUILDING CODE OF AUSTRALIAPROVIDE TACTILE INDICATORS IN ACCORDANCE WITH AS1428.4EXIT DOOR TO BE PROVIDED WITH SIGNAGE IN ACCORDANCEWITH D2.23 OF THE BUILDING CODE OF AUSTRALIA.CONSTRUCTION JOINTS TO BE PROTECTED IN ACCORDANCEWITH AS1530.4 AND THE BUILDING CODE OF AUSTRALIA.
DESIGN AND OPERATION OF EXIT SIGNS TO COMPLYWITH AS2293.1 OR SPECIFICATION E4.8 OF THE BUILDING CODEROOF SHEETING TO BE INSTALLED IN ACCORDANCEWITH AS1562.1 AND AS1562.3 AND THE BUILDING CODE.ENTRY/EXIT DOORS TO BE CLEARLY MARKEDIN ACCORDANCE WITH AS1428.1LIGHTWEIGHT CONSTRUCTION MUST BE CARRIED OUTIN ACCORDANCE WITH SPECIFICATION C1.8 OF THE BCA
ISSUED FOR CLIENT REVIEW & SIGNOFF02 15/04/20 SB
20032_YHSheet No.:
Scale:Status:
Plot Date:
Project No:
Drawing Title:
Project Name
Client
YARROWITCH HALL
The builder shall check and verify all dimensions and levels on site.All errors and omissions to be verified with the Designer before commencment on site.
Do not scale the drawings.Drawings shall not be used for construction purposes until issued for construction.
REV DATE AMENDMENT
15/4/20
/Volumes/Data/01 PROJECTS/01_CURRENT/20032 WALCHA COMMUNITY PROJECTS/YARROWITCH/20032_YARRROW.pln
1:1000, 1:200 @ A1PRELIMINARY
LOCATION/ ANALYSIS PLAN
All boundary locations and levels to be confirmed by a registered surveyor.All underground service location's to be confirmed.
Obtain and confirm all service connection approvals andrequirements before commencing onsite.
92 UPPER YARROWITCH RIVER ROADYARROWITCHNSW 2354
WALCHA SHIRE COUNCILD&CP R O J E C T Sb u i l d i n g d e s i g nd r a f t i n g s e r v i c e
www.d-cprojects.com.au
0 4 2 4 2 0 9 4 0 8
DT
WD210 30 40 50 100 15020 length in millimeters at full size 200
LOT 125DP 756475
15,0
00
31,755
21,450
U P P E R Y A R R O W I T C H R I V E R R O A D
EXISTING HALL
PROPOSEDCOVERED AREA
AMENITIES
AMEN
ITIE
S
EXISTINGPLAY EQUIPMENT
EXISTINGTREE
EXISTINGTREE
EXISTINGTREE
EXIS
TING
SITE
ACC
ESS
PP
SEPTIC
LOT 125DP 756475
N
DEVELOPMENT NOTESALL BUILDING WORK SHALL BE CARRIED OUTIN ACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA.PROVIDE DOWN PIPES IN ACCORDANCE WITH THE BUILDINGCODE OF AUSTRALIA & AS2180 METAL RAINWATER GOODS.PROVIDE WATERPROOFING SYSTEM TO ALL WET AREASIN ACCORDANCE WITH PART F1-7 OF THE BUILDING CODE.PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS3660.1PROVIDE TIE DOWN AND BRACING IN ACCORDANCE WITHAS1684.2 AND STRUCTURAL ENGINEERS RECOMMENDATIONSBUILDER TO ENSURE A SMOKE DETECTION SYSTEMIS INSTALLED IN ACCORDANCE WITH AS2441
LEGENDSWP STORMWATER PITSC STEEL COLUMNDP DOWN PIPERC REINFORCED CONCRETEWM WATER METERPP POWER POLEHWU HOT WATER UNITMSB MAIN SWITCH BOARDFFL FINISHED FLOOR LEVELFSL FINISHED SLAB LEVELEGL EXISTING GROUND LEVELFGL FINISHED GROUND LEVEL
LOCATION PLANSCALE 1:1000@A1
SITE SETOUT PLANSCALE 1:200@A1
ISSUED FOR CLIENT REVIEW & SIGNOFF01 31/03/20 SB
PROVIDE ACCESSIBLE SIGNAGE IN ACCORDANCE WITH AS1428.1FIRE HOSE REELS TO BE INSTALLED IN ACCORDANCE WITH AS2441INSULATION MUST BE INSTALLED IN ACCORDANCE WITHSECTION J1.5 &J1.6 &J1.3 OF THE BUILDING CODE.ALL LEVELS ARE INDICATIVE AND SHOULD BE CONFIRMED.ALL RAMPS/STAIRS TO BE INSTALLED IN ACCORDANCE WITHAS1428.1.AND HAS SLIP RESISTANT SURFACES IN ACCORDANCE WITHTABLE D2.14 OF THE BUILDING CODE OF AUSTRALIAPROVIDE TACTILE INDICATORS IN ACCORDANCE WITH AS1428.4EXIT DOOR TO BE PROVIDED WITH SIGNAGE IN ACCORDANCEWITH D2.23 OF THE BUILDING CODE OF AUSTRALIA.CONSTRUCTION JOINTS TO BE PROTECTED IN ACCORDANCEWITH AS1530.4 AND THE BUILDING CODE OF AUSTRALIA.
DESIGN AND OPERATION OF EXIT SIGNS TO COMPLYWITH AS2293.1 OR SPECIFICATION E4.8 OF THE BUILDING CODEROOF SHEETING TO BE INSTALLED IN ACCORDANCEWITH AS1562.1 AND AS1562.3 AND THE BUILDING CODE.ENTRY/EXIT DOORS TO BE CLEARLY MARKEDIN ACCORDANCE WITH AS1428.1LIGHTWEIGHT CONSTRUCTION MUST BE CARRIED OUTIN ACCORDANCE WITH SPECIFICATION C1.8 OF THE BCA
NOTE:ALL WORK IS TO BE CARRIED OUT INACCORDANCE WITH THE NATIONALCONSTRUCTION CODE CLAUSES:C1.10 FIRE HAZARD PROPERTIESD2.19 OPERATION OF POWER OPERATED DOORSD2.21 OPERATION OF LATCHESD3.6 BRAILLE AND TACTILE SIGNAGEF1.7 WATERPROOFING OF WET AREASF1.13 GLAZED ASSEMBLIESG1.3 OUTDOOR PLAY AREAS TOBE ENCLOSED AND AS1428.1
ISSUED FOR CLIENT REVIEW & SIGNOFF02 15/04/20 SB
20032_YHSheet No.:
Scale:Status:
Plot Date:
Project No:
Drawing Title:
Project Name
Client
YARROWITCH HALL
The builder shall check and verify all dimensions and levels on site.All errors and omissions to be verified with the Designer before commencment on site.
Do not scale the drawings.Drawings shall not be used for construction purposes until issued for construction.
REV DATE AMENDMENT
15/4/20
/Volumes/Data/01 PROJECTS/01_CURRENT/20032 WALCHA COMMUNITY PROJECTS/YARROWITCH/20032_YARRROW.pln
1:100 @ A1PRELIMINARY
PROPOSED FLOOR PLAN
All boundary locations and levels to be confirmed by a registered surveyor.All underground service location's to be confirmed.
Obtain and confirm all service connection approvals andrequirements before commencing onsite.
92 UPPER YARROWITCH RIVER ROADYARROWITCHNSW 2354
WALCHA SHIRE COUNCILD&CP R O J E C T Sb u i l d i n g d e s i g nd r a f t i n g s e r v i c e
www.d-cprojects.com.au
0 4 2 4 2 0 9 4 0 8
DT
WD310 30 40 50 100 15020 length in millimeters at full size 200
13-0
8SW
13-0
8SW 12
-08S
W12
-08S
W
13-15SW 13-15SW 13-15SW9202/820
13-26SW 13-26SW 13-24SW 13-23SW 13-22SW 13-23SW
09-1
4SW
820
09-1
5SW
s.
ST
ST
1,50
08,
000
1,50
0
2,76
0
1,500 12,820 1,500
1,000
1,000
1,00
0
1,00
0
1,00
0
1,00
0
1,500
4,62
5
4,570
1,000
1,000
1,000
EXISTINGHALL AUDITORIUM
EXISTFOYER
EXISTINGAMENITIES
EXISTINGAMENITIES
EXISTINGKITCHEN
EXISTINGENTERTAINING
AREA
EXISTINGOFFICE
STAGE
CHANGERM
CHANGERM
EXISTINGACCESS HALLWAY
1
1 1
2
2
3
2
2
2
222
2
4
4
STAGE 1: - LINE INTERNAL WALLS MARKED. PROVIDE ADEQUATE SARKING AND INSULATION. (RECOMMENDED R2.0 INSULATION)
- REPLACE MARKED TIMBER WINDOW SURROUNDS WITH LOW MAINTENANCE MATERIAL AND PAINT(COLOUR SELECTED BY CLIENT).
- REPLACE MARKED EXISTING DOORS WITH NEW LOW MAINTENANCE MATERIAL AND PAINT(COLOUR SELECTED BY CLIENT).
- REPAIR AND PATCH EXISTING CONCRETE AS MARKED.
- REPLACE EXISTING GUTTERS TO AREAS MARKED. PAINT BARGE AND FASCIAS AS NECESSARY. PROVIDE ADDITIONAL DOWNPIPES AS NOTED.
- CONSTRUCT NEW COVERED OUTDOOR AREA AS SHOWN. ENSURE ALL WORK IS COMPLETED TO ENGINEERS DETAILS.
- PROVIDE NEW RAINWATER TANK AS SHOWN. CONNECT EXISTING AND NEW DOWNPIPES AS SHOWN.
- PROVIDE NEW CONCRETE FOOTPATHS AS MARKED.
- PROVIDE NEW SUN HOODS TO WINDOWS MARKED.
BUILDER TO ENSURE ALL NEW WORKS ARE CARRIED OUT BY COMPETENTCONSULTANTS AND TRADESPEOPLE. ENSURE ALL NEW WORK IS CARRIEDOUT IN ACCORDANCE WITH RELEVANT BUILDING CODES AND AUSTRALIANSTANDARDS. ALL EXISTING MEASUREMENTS ARE GUIDES ONLY AND ALLWORK/ DIMENSIONS SHOULD BE CHECKED PRIOR TO ANY WORK COMMENCINGON SITE.
1
2
3
4
6
7
8
POTENTIAL FUTURE PROJECTS - PROVIDE NEW LINING TO UNDERSIDE OF RAFTERS. PROVIDE ADEQUATE SARKING AND INSULATION. (RECOMMENDED R3.5 INSULATION) REPAIR OR REPLACE ANY DAMAGED ROOF STRUCTURE.
- REMOVE INTERNAL WALL LININGS AND REPLACE WITH NEW LININGS TO MATCH EXISTING.
- REMOVE EXISTING FLOOR COVERING AND REPLACE WITH NEW FLOORBOARD TO MATCH EXISTING.
- REMOVE EXISTING CEILING LINING AND REPLACE WITH NEW PLASTERBOARD LINING TO UNDERSIDE OF STRUCTURE. PROVIDE NECESSARY REPAIRS TO ANY DAMAGED STRUCTURE. PROVIDE NEW SARKING AND INSULATION AS REQUIRED (RECOMMEND R3.5 INSULATION)
- REPLACE EXISTING CONCRETE RAMPS WITH NEW LANDINGS AND BUILDING CODE/AUSTRALIAN STANDARD COMPLIANT ACCESS RAMP.
BUILDER TO ENSURE ALL NEW WORKS ARE CARRIED OUT BY COMPETENTCONSULTANTS AND TRADESPEOPLE. ENSURE ALL NEW WORK IS CARRIEDOUT IN ACCORDANCE WITH RELEVANT BUILDING CODES AND AUSTRALIANSTANDARDS. ALL EXISTING MEASUREMENTS ARE GUIDES ONLY AND ALLWORK/ DIMENSIONS SHOULD BE CHECKED PRIOR TO ANY WORK COMMENCINGON SITE.
5
5
8
8 8
8
PROPOSED COVEREDOUTDOOR AREA
5
5
5
5
5
5
6
1
2
3
4
5
1
2
2
2
2
3 4
44
5
5
C1 C1 C1 C1
C1 C1 C1 C1
EXISTING ITEMS CURRENTLY NOT TO STANDARD - EXISTING DISABLED PEDESTRIAN ACCESS RAMP GRADIENT CURRENT APPROXIMATE GRADIENT 1 IN 9, REQUIRED TO BE 1 IN 14
- EXISTING DISABLED PEDESTRIAN ACCESS RAMP REQUIRES NEW HANDRAILS IN ACCORDANCE WITH AS1428.1
- MAIN PUBLIC HALL ACCESS DOOR. DOOR APPROACH DOES NOT MEET AS1428.1 PORCH WOULD BE REQUIRED TO BE WIDENED TO COMPLY.
- DOOR REQUIRES LANDING AND STAIR IN ACCORDANCE WITH AS1428.1 AND THE BUILDING CODE.
- ACCESS RAMPS NEED TO BE UPGRADED TO MATCH CURRENT CODES AND STANDARDS.
EXISTINGWATER TANK
EXISTINGWATER TANK
DP
DP
DP
DP
DP DP DP
DP
DP
DP
1
2
3
4
5
5
5
12 2
3
4
PROPOSEDWATER TANK
9
9 9 9 9
9
9
9
9
2 2 2 2 2 2
9
s.
ST
ST
140 EXIST 2,945 180 EXIST 18,165 100 EXIST 2,310 180 EXIST 10,305
EXIST 1,585EXIST 1,500
EXIST 3,070 140 EXIST 3,660 140 EXIST 8,390 140 EXIST 4,130 140 EXIST 1,125 EXIST 10,305
EXIST 6,155 140 EXIST 16,460 140 EXIST 5,370 150 EXIST 5,760 150
EXIST 21,975 190 EXIST 3,590 190 EXIST 8,380
EX
IST
15,4
35E
XIS
T 7,
775
EX
IST
1,31
514
0E
XIS
T 2,
670
140
EX
IST
3,51
5
EX
IST
21,4
2018
0E
XIS
T 9,
210
180
EX
IST
12,3
1014
0E
XIS
T 2,
270
140
EX
IST
6,56
018
0E
XIS
T 9,
210
180
EX
IST
12,3
1014
0E
XIS
T 5,
910
140
EX
IST
2,92
018
0E
XIS
T 9,
210
180
EX
IST
10,1
35E
XIS
T 2,
175
140
EX
IST
2,90
014
0E
XIS
T 5,
930
180
EX
IST
2,29
010
0E
XIS
T 4,
495
100
EX
IST
2,22
518
0
EX
IST
11,1
35E
XIS
T 7,
765
EX
IST
12,0
90
EXISTINGHALL AUDITORIUM
EXISTFOYER
EXISTINGAMENITIES
EXISTINGAMENITIES
EXISTINGKITCHEN
EXISTINGENTERTAINING
AREA
EXISTINGOFFICE
STAGE
CHANGERM
CHANGERM
EXISTINGACCESS HALLWAY
EXISTINGWATER TANK
EXISTINGWATER TANK
DP
DP
DP
DP
DP DP DP
DP
DP
DP
NOTE: EXISTING CONCRETE FOOTPATHSHOWN DASHED TO BE DEMOLISHED.PREPARE SUFACE FOR NEW WORK.ALL NEW WORK TO BE CARRIED OUT INACCORDANCE WITH RELEVANT BUILDINGCODES AND AUSTRALIAN STANDARDS
NOTE: EXISTING DOWNPIPE TRANSFERPIPE TO BE REMOVED TO ALLOWFOR WINDOW SUNHOOD/ AWNING.PROVIDE NEW STORMWATERTRENCH AND CONNECT TO TANK.
NOTE: CUT EXISTING SLAB TO ALLOW FORNEW STORMWATER TRENCH AND PIPING.ENSURE NEW WORK IS CARRIED OUT INACCORDANCE WITH RELEVANT BUILDINGCODES AND AUSTRALIAN STANDARDS
N
FLOOR AREASEXISTING HALL INTERNAL AREAS 364.8m²EXISTING AMENITIES AREAS 84.0m²EXISTING PORCH/ACCESS RAMP AREA 15.7m²EXISITNG FOOTPATH AREAS 28.9m²PROPOSED COVERED OUTDOOR AREA 102.6m²PROPOSED FOOTPATH ADDITIONS 85.2m²TOTAL 681.2m²
LEGENDTP TIMBER POSTBP BRICK PEIRSC STEEL COLUMNDP DOWN PIPERC REINFORCED CONCRETEFW FLOOR WASTEHWU HOT WATER UNITMSB MAIN SWITCH BOARDFFL FINISHED FLOOR LEVELFSL FINISHED SLAB LEVELEGL EXISTING GROUND LEVELFGL FINISHED GROUND LEVEL
EXISTING/ DEMOLITION PLANSCALE 1:100@A1
PROPOSED FLOOR PLANSCALE 1:100@A1
NOTE:ALL WORK IS TO BE CARRIED OUT INACCORDANCE WITH THE NATIONALCONSTRUCTION CODE CLAUSES:C1.10 FIRE HAZARD PROPERTIESD2.19 OPERATION OF POWER OPERATED DOORSD2.21 OPERATION OF LATCHESD3.6 BRAILLE AND TACTILE SIGNAGEF1.7 WATERPROOFING OF WET AREASF1.13 GLAZED ASSEMBLIESG1.3 OUTDOOR PLAY AREAS TOBE ENCLOSED AND AS1428.1
DEVELOPMENT NOTESALL BUILDING WORK SHALL BE CARRIED OUTIN ACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA.PROVIDE DOWN PIPES IN ACCORDANCE WITH THE BUILDINGCODE OF AUSTRALIA & AS2180 METAL RAINWATER GOODS.PROVIDE WATERPROOFING SYSTEM TO ALL WET AREASIN ACCORDANCE WITH PART F1-7 OF THE BUILDING CODE.PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS3660.1PROVIDE TIE DOWN AND BRACING IN ACCORDANCE WITHAS1684.2 AND STRUCTURAL ENGINEERS RECOMMENDATIONSBUILDER TO ENSURE A SMOKE DETECTION SYSTEMIS INSTALLED IN ACCORDANCE WITH AS2441
ISSUED FOR CLIENT REVIEW & SIGNOFF01 31/03/20 SB
PROVIDE ACCESSIBLE SIGNAGE IN ACCORDANCE WITH AS1428.1FIRE HOSE REELS TO BE INSTALLED IN ACCORDANCE WITH AS2441INSULATION MUST BE INSTALLED IN ACCORDANCE WITHSECTION J1.5 &J1.6 &J1.3 OF THE BUILDING CODE.ALL LEVELS ARE INDICATIVE AND SHOULD BE CONFIRMED.ALL RAMPS/STAIRS TO BE INSTALLED IN ACCORDANCE WITHAS1428.1.AND HAS SLIP RESISTANT SURFACES IN ACCORDANCE WITHTABLE D2.14 OF THE BUILDING CODE OF AUSTRALIAPROVIDE TACTILE INDICATORS IN ACCORDANCE WITH AS1428.4EXIT DOOR TO BE PROVIDED WITH SIGNAGE IN ACCORDANCEWITH D2.23 OF THE BUILDING CODE OF AUSTRALIA.CONSTRUCTION JOINTS TO BE PROTECTED IN ACCORDANCEWITH AS1530.4 AND THE BUILDING CODE OF AUSTRALIA.
DESIGN AND OPERATION OF EXIT SIGNS TO COMPLYWITH AS2293.1 OR SPECIFICATION E4.8 OF THE BUILDING CODEROOF SHEETING TO BE INSTALLED IN ACCORDANCEWITH AS1562.1 AND AS1562.3 AND THE BUILDING CODE.ENTRY/EXIT DOORS TO BE CLEARLY MARKEDIN ACCORDANCE WITH AS1428.1LIGHTWEIGHT CONSTRUCTION MUST BE CARRIED OUTIN ACCORDANCE WITH SPECIFICATION C1.8 OF THE BCA
ISSUED FOR CLIENT REVIEW & SIGNOFF02 15/04/20 SB
20032_YHSheet No.:
Scale:Status:
Plot Date:
Project No:
Drawing Title:
Project Name
Client
YARROWITCH HALL
The builder shall check and verify all dimensions and levels on site.All errors and omissions to be verified with the Designer before commencment on site.
Do not scale the drawings.Drawings shall not be used for construction purposes until issued for construction.
REV DATE AMENDMENT
15/4/20
/Volumes/Data/01 PROJECTS/01_CURRENT/20032 WALCHA COMMUNITY PROJECTS/YARROWITCH/20032_YARRROW.pln
1:100 @ A1PRELIMINARY
ELEVATIONS
All boundary locations and levels to be confirmed by a registered surveyor.All underground service location's to be confirmed.
Obtain and confirm all service connection approvals andrequirements before commencing onsite.
92 UPPER YARROWITCH RIVER ROADYARROWITCHNSW 2354
WALCHA SHIRE COUNCILD&CP R O J E C T Sb u i l d i n g d e s i g nd r a f t i n g s e r v i c e
www.d-cprojects.com.au
0 4 2 4 2 0 9 4 0 8
DT
WD410 30 40 50 100 15020 length in millimeters at full size 200
FSL
FCL
EX
ISTI
NG
HA
LLC
EIL
ING
HE
IGH
T 3,
600
AP
PR
OX
RID
GE
HE
IGH
T 6,
565
REPL
ACE
EXIS
TING
TIM
BER
WIN
DOW
CAS
INGS
PROP
OSED
SUN
HOO
DSTO
CLIE
NT S
PECI
FICA
TION
REPL
ACE
EXIS
TING
GUT
TER
AND
FASC
IA A
S SE
LECT
ED
REPL
ACE
EXIS
TING
GUT
TER
AND
FASC
IA A
S SE
LECT
ED
APPROX EXISTING PITCH 3º
EXISTING GROUND LEVELFSL
FCL
EX
ISTI
NG
HA
LLC
ELI
ING
HE
IGH
T 3,
600
CO
VE
RE
D A
RE
AP
ITC
HIN
G P
OIN
T3,2
00
500
REPL
ACE
EXIS
TING
TIM
BER
WIN
DOW
CAS
INGS
PROP
OSED
SUN
HOO
DSTO
CLIE
NT S
PECI
FICA
TION
REPL
ACE
EXIS
TING
GUT
TER
AND
FASC
IA A
S SE
LECT
ED
REPL
ACE
EXIS
TING
GUT
TER
AND
FASC
IA A
S SE
LECT
ED
PROP
OSED
SUN
HOO
DSTO
CLIE
NT S
PECI
FICA
TION
PROP
OSED
COL
ORBO
NDCL
ADDI
NG T
O FA
CE O
F EX
TERN
ALTR
USS
ON G
ABLE
END
COLO
RBON
D RO
OF S
HEET
ING
TO M
ATCH
EXI
STIN
G
STEE
L COL
UMN
APPROX EXISTING PITCH 30º
APPROX EXISTING PITCH 7.5º
ROOF PITCH 15º
REPA
IR, R
EPLA
CE O
R RE
PAIN
TEX
ISTI
NG G
ABLE
END
FASC
IA
EXISTING GROUND LEVEL
FSL
FCL
REPL
ACE
EXIS
TING
GUT
TER
AND
FASC
IA A
S SE
LECT
ED
PROP
OSED
SUN
HOO
DSTO
CLIE
NT S
PECI
FICA
TION
COLO
RBON
D RO
OF S
HEET
ING
TO M
ATCH
EXI
STIN
G
STEE
L COL
UMN
APPROX EXISTING PITCH 3º
EXISTING GROUND LEVEL
APPROX EXISTING PITCH 1º
REPL
ACE
EXIS
TING
TIM
BER
WIN
DOW
CAS
INGS
FSL
FCL
REPL
ACE
EXIS
TING
TIM
BER
WIN
DOW
CAS
INGS
REPL
ACE
EXIS
TING
GUT
TER
AND
FASC
IA A
S SE
LECT
ED
PROP
OSED
SUN
HOO
DSTO
CLIE
NT S
PECI
FICA
TION
PROP
OSED
COL
ORBO
NDCL
ADDI
NG T
O FA
CE O
F EX
TERN
ALTR
USS
ON G
ABLE
END
COLO
RBON
D RO
OF S
HEET
ING
TO M
ATCH
EXI
STIN
G
STEE
L COL
UMN
REPA
IR, R
EPLA
CE O
R RE
PAIN
TEX
ISTI
NG G
ABLE
END
FASC
IA
APPROX EXISTING PITCH 30º
EXISTING GROUND LEVEL
ROOF PITCH 15º
SOUTHERN ELEVATIONSCALE 1:100@A1
EASTERN ELEVATIONSCALE 1:100@A1
NORTHERN ELEVATIONSCALE 1:100@A1
WESTERN ELEVATIONSCALE 1:100@A1
ISSUED FOR CLIENT REVIEW & SIGNOFF01 31/03/20 SBDEVELOPMENT NOTESALL BUILDING WORK SHALL BE CARRIED OUTIN ACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA.PROVIDE DOWN PIPES IN ACCORDANCE WITH THE BUILDINGCODE OF AUSTRALIA & AS2180 METAL RAINWATER GOODS.PROVIDE WATERPROOFING SYSTEM TO ALL WET AREASIN ACCORDANCE WITH PART F1-7 OF THE BUILDING CODE.PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS3660.1PROVIDE TIE DOWN AND BRACING IN ACCORDANCE WITHAS1684.2 AND STRUCTURAL ENGINEERS RECOMMENDATIONSBUILDER TO ENSURE A SMOKE DETECTION SYSTEMIS INSTALLED IN ACCORDANCE WITH AS2441
PROVIDE ACCESSIBLE SIGNAGE IN ACCORDANCE WITH AS1428.1FIRE HOSE REELS TO BE INSTALLED IN ACCORDANCE WITH AS2441INSULATION MUST BE INSTALLED IN ACCORDANCE WITHSECTION J1.5 &J1.6 &J1.3 OF THE BUILDING CODE.ALL LEVELS ARE INDICATIVE AND SHOULD BE CONFIRMED.ALL RAMPS/STAIRS TO BE INSTALLED IN ACCORDANCE WITHAS1428.1.AND HAS SLIP RESISTANT SURFACES IN ACCORDANCE WITHTABLE D2.14 OF THE BUILDING CODE OF AUSTRALIAPROVIDE TACTILE INDICATORS IN ACCORDANCE WITH AS1428.4EXIT DOOR TO BE PROVIDED WITH SIGNAGE IN ACCORDANCEWITH D2.23 OF THE BUILDING CODE OF AUSTRALIA.CONSTRUCTION JOINTS TO BE PROTECTED IN ACCORDANCEWITH AS1530.4 AND THE BUILDING CODE OF AUSTRALIA.
DESIGN AND OPERATION OF EXIT SIGNS TO COMPLYWITH AS2293.1 OR SPECIFICATION E4.8 OF THE BUILDING CODEROOF SHEETING TO BE INSTALLED IN ACCORDANCEWITH AS1562.1 AND AS1562.3 AND THE BUILDING CODE.ENTRY/EXIT DOORS TO BE CLEARLY MARKEDIN ACCORDANCE WITH AS1428.1LIGHTWEIGHT CONSTRUCTION MUST BE CARRIED OUTIN ACCORDANCE WITH SPECIFICATION C1.8 OF THE BCA
NOTE:ALL WORK IS TO BE CARRIED OUT INACCORDANCE WITH THE NATIONALCONSTRUCTION CODE CLAUSES:C1.10 FIRE HAZARD PROPERTIESD2.19 OPERATION OF POWER OPERATED DOORSD2.21 OPERATION OF LATCHESD3.6 BRAILLE AND TACTILE SIGNAGEF1.7 WATERPROOFING OF WET AREASF1.13 GLAZED ASSEMBLIESG1.3 OUTDOOR PLAY AREAS TOBE ENCLOSED AND AS1428.1
ISSUED FOR CLIENT REVIEW & SIGNOFF02 15/04/20 SB