Page 1: Artromick Pintrax Pc Program for Hospital Computing Solutions

PINTRAX PC Access Manual

© 2000 Artromick International. All Rights Reserved. Artromick and Pintrax are registered trademarks of Artromick International. All other trademarks are the property of their respective owners. Rev. 2

Page 2: Artromick Pintrax Pc Program for Hospital Computing Solutions

2Software

Overview

Minimum Requirements

The PINTRAX PC program is used to read information from and program the

PINTRAX cart. Users can be added, edited, and deleted from the cart using the

program. The events (almost 3000) can be loaded into the PC and searched by

User ID, date of occurrence, or type of event. The cart’s settings can be viewed

and the program can be used to print reports.

Access to cart information via the PINTRAX program is controlled by the user’s

type. Each user has a type and each type has associated abilities that are set up

by the factory on a cart-by-cart basis. When a user enters their Access Code into

the cart, the cart looks up that users type and their abilities. Three of those

abilities

PC-Events, PC-Users, and PC-Cart Settings are important with regard to the

PINTRAX program.

Windows 95, 98 & NT

• 80386 or higher microprocessor.

• VGA or higher resolution screen supported by Microsoft Windows.

• 8 MB of RAM.

• Open serial port. COM1 to COM4 are supported.

• A mouse or other pointing devise is not necessary but is preferred.

Page 3: Artromick Pintrax Pc Program for Hospital Computing Solutions

3Software

Program Installation

1. Start Windows.

2. Make sure that no other programs are running in the background.

3. Insert the CD into the CD drive of your computer.

4. Using Windows 95 or 98 use the Win95 98 Start Button, Select the Run

option. In the resulting dialog box type the following: D:\setup (substitute

the letter of your CD drive if different than D) and press the Enter key.

5. Follow the directions.

Please Note: Depending on the current version of the operating system,

you may be prompted to upgrade your software. Select Yes and Pintrax PC

program will perform this operation. Once the upgrade is performed, you

will need to restart your computer and then install Pintrax PC program.

Page 4: Artromick Pintrax Pc Program for Hospital Computing Solutions

3. Choose the type of connection. Select the type of connection needed.

4Software

Running the Pintrax PC Program

Setting up the Pintrax PC Access Program

1. Plug into the computers COM Port.

Plug the 9 pin or 25 adapter and phone cable into a free COM port on your

computer. COM1 to COM4 are supported by the program. Record which

COM port you plugged into. You will need to select it when the program is

first run and each time you change it thereafter.

2. Start the PINTRAX program.

Select Start then Programs then select the PINTRAX program.

Note: If this is the first time use, you will see the window below, select OK.

These features will be explored in detail in the pages to follow.

* This modem is available only through Artromick International. Please contactTech Support @ 800-848-6462 for more information.

By selecting “Comm Port” you can connect to

the med cart via a comm port on your PC and

a direct link cable connection.

Selecting “Modem” allows you to connect via

your computer’s modem standard telephone

connection and a special modem* at the other

end of telephone connection.

Selecting “Off Line” allows you to manage or

work with files away from or disconnected

from your med cart.

Page 5: Artromick Pintrax Pc Program for Hospital Computing Solutions

5Software

Comm Port

1. Be sure the “comm port” has been selected and click continue.

2. You will now be prompted to select a comm port (this is specific to your

computer, if you are unsure, contact your IS personnel or computer

specialist)* and baud rate (to start with select a baud rate of 9600. If you

have communication problems you can reduce the baud rate later.)

* If you are still unsure you can click on the radio button “Test Comm Port”. This may assist you but is not a guarantee that you have selected the correct comm port.

3. Select “Continue” and you will see the following window.

Page 6: Artromick Pintrax Pc Program for Hospital Computing Solutions

6Software

Comm Port

Setting up the Cart

4. You will now need to prepare your cart for connecting. Please follow the

instructions for setting up the cart.

1. Press Wake-Up.

Temporary display 2 seconds

2. Press Recall.

3. Enter 4-digit code.

Use Clear key if a mistake is made.

This screen will only show if the user has the ability to connect to a computer.

HELLO

ENTER CODE

ENTER CODE

FOR RECALLING

***

LINK TO PC?

Page 7: Artromick Pintrax Pc Program for Hospital Computing Solutions

1. Click on the “Sign In” Button.

When the PC detects that a cart is connected it enables the “Sign-In” button,

and changes the Connection Status display to “Please Sign In.”

The spinning cursor indicates that the PC is reading information from the cart.

When the PC is finished the Connection Status display will change to

“Connected @ 9600 Baud” and the Settings, Users, or Events buttons may

become enabled.

5. Press Enter.

The cart is connecting to the PC. When it does connect the screen changes

from “Linking” to “Linked.”

If the cart does not link with PC, make sure that the cart baud rate is the same

as the PC’s baud rate. Use the up/down keys on the cart to change it’s baud

rate, and use the “Comm” pull down menu then choose “Select Again” to

change the PC’s baud rate.

7Software

Signing In

LINKED TO PC.

9600 BAUD END

LINKING TO PC.

9600 BAUD END

4. Press Yes.

Open the area of the cart where the COM port is located and plug the cable in.

CONNECT PC CABLE

PRESS ENTER

Page 8: Artromick Pintrax Pc Program for Hospital Computing Solutions

8Software

Settings

1. Click on the Settings Button.

If you’ve signed in and the Settings button is not enabled (it’s grayed out), then

your user type does not have the ability to read the cart settings using the PC.

The spinning cursor indicates that the PC is reading information from the cart.

All of the settings “grayed out” cannot be changed. All other settings can be

changed here. This form is useful for troubleshooting with Tech Support.

Please Note: In this instance the PC user cannot add, delete or change user

types. When logging in as a matter the “Abilities” can be changed.

General Use of the PC Program

Page 9: Artromick Pintrax Pc Program for Hospital Computing Solutions

9Software

Cart Number: Each cart has an individual number.

Auto Sec Delay: The auto secure delay is the number of minutes that the cart

can be left unattended before it attempts to auto secure.

Configuration: This is a physical description of the cart. From the top down it

shows the “type,”“orientation,” “size,”“number of cabinets” and “height.”

Personal Editing: Personal editing is either enabled (“Yes”), or disabled (“No”).

If enabled any user can change their Access Code (not their ID) by entering the

Program Mode and following the directions.

Time: Two times and dates are shown, one for the cart and one for the PC.

Areas Utilized: The areas in use are indicated by a check in the box.“N1” stands

for Narc Drawer #1,“Z8” stands for Zone #8.

Perimeter Alarm: The perimeter alarm is active in the areas checked.

Pcb Rev/Max Users: The PCB (Printed Circuit Board) revision level of the cart is

shown in this window. If your cart needs servicing-this value may be needed.

The number of users that may be added is shown in the Max Users box.

BeepF/Comm is in: The beeper frequency may be high, medium, or low. The

“Comm is in” box shows the location of the comm port. For example, a “Z8” in

this window indicates that the comm port is located in Zone #8.

Open Time: Indicates the time that a particular zone or narc drawer will be held

open.

Narc Type: The narc type may be “general” or “specific.”

Abilities: The different user types are abbreviated along the top row.

“M”=Master,“T”=Technician,“S”=Special,“PC”=PC user,“KS”=Key Switch,

“N”=Nurse. The abilities are shown vertically on the right hand side of the

screen. A checked box indicates that the user type shown in that column has the

ability shown in that row.

Settings definitions

Page 10: Artromick Pintrax Pc Program for Hospital Computing Solutions

10Software

Users

1. Click on the Users Button.

If you’ve signed in and the Users button is not enabled (it’s grayed out), then

your user type does not have the ability to read the Users using the PC.

The spinning cursor indicates that the PC is reading information from the cart.

The users can be viewed, edited, and added to using the PC.

By clicking this button, this assures you that the information you are vewing is

what is programmed in the cart.

The File Menu allows you to open previous edited or managed files for viewing

of downloading. When opening files, you are forced to the Batch mode. This also

allows you to save current user information. You can also print the entire list

here or a “snap shot” with “print form”.

Adding a user:

Click on an empty line, or use the “Add” pull down. Fill in the form and click on

“Apply.”

Page 11: Artromick Pintrax Pc Program for Hospital Computing Solutions

11Software

Events

1. Click on the events button.

You will see the following window after clicking on the Events button.

Click on cart, then read and the following window will appear.

Editing a user:

Click on the user to be edited, or use the “Edit” pull down and enter the user’s

number. Change as desired and choose “Apply.”

Deleting a user:

Click on the user to be deleted, or use the “Edit” pull down and enter the user’s

number. Choose the “Delete” button.

Sorting users:

When this box is checked the users are displayed by type and then ID number.

If unchecked they are displayed in the order they occur in memory, which is

roughly the order they were added in.

Update mode:

“Immediate” will work quicker with one or two changes.“Batch” operates better

for large changes or file downloads.

Page 12: Artromick Pintrax Pc Program for Hospital Computing Solutions

12Software

The PINTRAX cart stores almost 3000 events. Depending on how many events

are generated each day the cart may contain events from several weeks back. If

you want to read all of the events in the cart select the “All Events” button. If you

only want to read the events back to a certain date select the “Events Back To”

button, and fill in the date and time. Then click the Proceed button. The spinning

curser indicates the events are being read. Depending on how many events

there are, the time may vary. The most recent event is shown at the top of the

form. Use the scroll bar to go down and back in time.

Searching by User:

Click on the Enable box under the User ID Search Parameter box. The form

rewrites to display only those events that have ID’s matching the value shown in

the parameter box. Use the scroll bar next to the box to find the desired ID.

Searching by Date:

Click on the Enable box under the Time and Date Search Parameter box. The

form rewrites to display only those events that have dates between the from/to

values in the parameter box.

Searching by Type of Event:

Click on the Enable box under the Event Type Search Parameter box. The form

rewrites to display only those events of the type shown in the parameter box.

Use the scroll bar next to the box to find the desired type.

The above searches may be combined in any order.

Events

Page 13: Artromick Pintrax Pc Program for Hospital Computing Solutions

The modem connection allows you to connect to a med cart via a standard

modem on your PC to a special modem at the med cart. The special modem is

available only through Artromick International. This modem is a standard US

Robotics specially modified for this purpose. This modem can also be used by

Factory Personnel to diagnose and manage your med cart.

1. Select the modem settings and click Continue.

Select the modem Port and Band Rate. Enter the phone number including any

necessary numbers or ____________ as needed.

Once connected, the software operates as though you were connected via a

“Comm” port. Because of external conditions this type of connection will

operate much slower. You may also experience difficulty with interruption of

phone service similar with any phone connection.

Modem

13Software

Page 14: Artromick Pintrax Pc Program for Hospital Computing Solutions

Offline

14Software

“Offline Connection” is not a true connection. This mode allows you to print, edit

or manage cart files while away or disconnected from your med cart.

Select “offline” and click “continue.

Note the “Com Not Open” below the mouse pointer as

indicated below.

You can manage your files, open, save or change in this

mode as you would with any windows application.

Page 15: Artromick Pintrax Pc Program for Hospital Computing Solutions