April 15, 2019 Asbestos Survey For 63 Downing Street, Columbia, SC Prepared for: City of Columbia Phone: (803) 545-3444 Attn: David Hatcher 1136 Washington Street Columbia, SC 29201 Prepared by: ABS Environmental, Inc. Phone: (803) 345-3833 1416 Chapin Road Chapin, SC 29036 ABS Job # 7800.19011 Inspection Performed by: SCDHEC # Lic Exp Date Jeff Rivers MP – 00166 8/1/19 Report Prepared by: SCDHEC # Lic Exp Date Jeff Rivers MP – 00166 8/1/19 Report Reviewed by: SCDHEC # Lic Exp Date Lee Capell MP – 00072 8/8/19
Transcript
Page 1: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

April 15, 2019

Asbestos Survey For

63 Downing Street, Columbia, SC

Prepared for: City of Columbia Phone: (803) 545-3444 Attn: David Hatcher

1136 Washington Street Columbia, SC 29201 Prepared by: ABS Environmental, Inc. Phone: (803) 345-3833

1416 Chapin Road Chapin, SC 29036

ABS Job # 7800.19011

Inspection Performed by:

SCDHEC # Lic Exp Date Jeff Rivers MP – 00166 8/1/19

Report Prepared by:

SCDHEC # Lic Exp Date Jeff Rivers MP – 00166 8/1/19

Report Reviewed by:

SCDHEC # Lic Exp Date Lee Capell MP – 00072 8/8/19

Page 2: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

TABLE OF CONTENTS

1.0 EXECUTIVE SUMMARY

2.0 APPENDIX

A. Drawing

B. Site Map

C. Tables

D. Laboratory Results

Page 3: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

1.0 EXECUTIVE SUMMARY

ABS Environmental, Inc. (ABS) was retained by the City of Columbia to perform an asbestos survey at 63 Downing Street in Columbia, SC. The primary objective of this survey was to identify, sample and physically assess suspect asbestos-containing building materials (ACBM) associated with the vacant residence. The subject structure is an approximately 1,023 ft2 two story, single family residence built over a crawlspace. The roof is built in gabled configuration and is covered with 3-tab composition shingles. The exterior is clad with wood siding. Interior finishes include: Ceilings/Walls: Sheetrock throughout. Floors: Combination of ceramic tile and wood. Ten (10) suspect materials were identified, sampled and analyzed for the presence of asbestos. Samples were delivered by overnight courier service to EMSL Analytical, Inc. for analysis using Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM) to confirm negative PLM results for non-friable organically bound materials. As indicated by laboratory analysis, those materials containing asbestos > 1 % include approximately:

3,581 ft2 of joint compound on the ceilings and walls.

192 LF of duct tape in the Crawlspace. Limitations This survey and report have been executed at the request of Mr. David Hatcher and City of Columbia and are intended solely for their use. All work related to this project has been conducted in keeping with accepted standards of environmental consulting as practiced in the State of South Carolina. No unnecessary destructive measures were undertaken during this survey. Additional suspect and/or asbestos containing materials may be present. If at any time during the course of renovation or demolition a suspect material is observed that is not identified in this report, stop work immediately until the material can be sampled and analyzed for the presence of asbestos. ABS has relied, in part, on information derived from secondary sources, and except as set forth herein, ABS has made no independent investigation as to the accuracy or completeness of the information derived from such secondary sources. No warranty is expressed or implied.

Page 4: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

DRAWINGS

Page 5: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011
Page 6: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

SITE MAP

Page 7: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

TABLES

Page 8: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Date:

* Assumed to Contain Asbestos > 1%

Observed ACBMMaterial EPA AHERA Category Quantity

Joint Compound: Ceilings Surfacing

Table #1Asbestos Containing Building Material (ACBM)

Project Name: 63 Downing StreetProject Address: 63 Downing St., Columbia, SC 15-Apr-19

Duct Tape Miscellaneous 192 LF

1,023 ft2

Joint Compound: Walls Surfacing 2,558 ft2

Page 9: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Date:

* Assumed to Contain Asbestos > 1%

Duct Tape 192 LFJoint Compound: Walls 2,558 ft2

Table #2Friable ACBM

Project Name: 63 Downing StreetProject Address: 63 Downing St., Columbia, SC 15-Apr-19

Friable ACBMMaterial Quantity

Joint Compound: Ceilings 1,023 ft2

Page 10: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Date:

F = Friable NF= Non Friable

G = Good (Very localized damage)

S = Surfacing Material (Spray-applied or trowel applied)

Suspect Material Category # Present Disturbance P or N P or N P or N HazardMaterial # Description (S, T, M) Samples Condition Potential PLM TEM Point Count Ranking

HM-01 Ceiling Texture S 3 498 ft2 F/G PD N NAHM-02 Sheetrock M 3 3,581 ft2 F/G PD N NA

Joint Comp: Ceilings 1,023 ft2 F/G PDJoint Comp: Walls 2,558 ft2 F/G PD

HM-04 Ceramic Tile Thinset M 3 70 ft2 F/G PD N NAHM-05 Duct Tape M 3 192 LF F/G PD P 2

HM-06 Exterior Caulk M 3 2 doors;17 windows NF/G PD N N NA

HM-07 Roof Shingles M 3 1535 NF/G PD N N NAHM-08 Felt Paper M 3 1535 NF/G LPD N N NAHM-09 Chimney Flashing M 3 8 LF NF/G PD N N NAHM-10 Wire Insulation T 3 72 LF NF/G PD N NA

Asbestos Finding; Asbestos Containing Material (ACM) contains > 1% asbestos by definition

Project Address: 15-Apr-1963 Downing St., Columbia, SC

Quantity

P = Positive via PLM

P = Positive via TEM

N = Negative: does not meet definition of ACM

A = Assumed to be ACM; no samples collected

Present Condition

SD = Significantly Damaged (Damage equal to or greater than 10 % distributed/ 25 % localized)

D = Damaged (Damage less than 10 distributed and less than 25 % localized)

M = Miscellaneous Materials (Refer to as "Other" materials by OSHA)

T = Thermal System Insulation (Inhibits heat transfer or prohibits condensation)

of High Concern or More Than One of Moderate Concern)

PSD = Potential for Significant Damage (One Mechanism

Potential for Future Disturbance by Contact, Vibration or Air Erosion Mechanisms

EPA AHERA Asbestos Category

Hazard Ranking = 7 thru 1; (7 being the worst i.e. significantly damaged material)

63 Downing Street

Table #3Asbestos - Suspect Material Data Sheet

Project Name:

PD = Potential for Damage (Any One Mechanism of Moderate Concern)

LPD = Low Potential for Disturbance (All Three Mechanisms of Low Concern)

PTP = Previously tested Positive

PTN = Previously tested Negative

HM-03 S 5 P 2

Page 11: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

* NAD = No Asbestos Detected Amos = Amosite

DNA = Did Not Analyze Croc = Crocidilite

Chry = ChrysotileAnth = Anthophylite

Date:

Assumed to contain Asbestos > 1%

Laboratory ABS Suspect Material Type * Percent Percent PercentSample # Sample # Material # Description Asbestos PLM TEM Point Count

021902219-0001 63-01 Office NAD021902219-0002 63-02 Bedroom 2 NAD021902219-0003 63-03 Bedroom 1 NAD021902219-0004 63-04 Den NAD021902219-0005 63-05 Kitchen NAD021902219-0006 63-06 Master Bedroom NAD

021902219-0004A 63-04 Den Chry 3%021902219-0005A 63-05 Kitchen Chry 2%021902219-0006A 63-06 Master Bedroom Chry 2%021902219-0007 63-07 Office Chry < 1%021902219-0008 63-08 Bedroom 2 Chry 2%021902219-0009 63-09 Bath 1 NAD021902219-0010 63-10 Bath 1 NAD021902219-0011 63-11 Bath 2 NAD021902219-0012 63-12 Chry 55%021902219-0013 63-13 Chry 60%

63-14 DNA021902219-0014 63-15 NAD021902219-0015 63-16 NAD021902219-0025 63-17 NAD021902219-0016 63-18 NAD021902219-0017 63-19 NAD021902219-0026 63-20 NAD

Ceramic Tile Thinset

Joint CompoundHM-03

HM-05 Duct Tape

HM-06 Exterior Caulk

Table #4Asbestos - Bulk Sample Data Sheet

Project Name:Project Address:

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via PLM

63 Downing Street63 Downing St., Columbia, SC 15-Apr-19

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via TEM

* Chry = Chrysotile Amos = Amosite Croc = Crocidolite Anth = Anthophylite NAD = No Asbestos Detected DNA = Did Not Analyze

HM-04

Location

Sheetrock HM-02

HM-01 Ceiling Texture

RoofShinglesHM-07

Crawlspace

Page 12: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

* NAD = No Asbestos Detected Amos = Amosite

DNA = Did Not Analyze Croc = Crocidilite

Chry = ChrysotileAnth = Anthophylite

Date:

Assumed to contain Asbestos > 1%

Laboratory ABS Suspect Material Type * Percent Percent PercentSample # Sample # Material # Description Asbestos PLM TEM Point Count

Table #4Asbestos - Bulk Sample Data Sheet

Project Name:Project Address:

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via PLM

63 Downing Street63 Downing St., Columbia, SC 15-Apr-19

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via TEM

* Chry = Chrysotile Amos = Amosite Croc = Crocidolite Anth = Anthophylite NAD = No Asbestos Detected DNA = Did Not Analyze

Location

021902219-0018 63-21 NAD021902219-0019 63-22 NAD021902219-0027 63-23 NAD021902219-0020 63-24 NAD021902219-0021 63-25 NAD021902219-0028 63-26 NAD021902219-0022 63-27 NAD021902219-0023 63-28 NAD021902219-0024 63-29 NAD

HM-10 Wire Insulation

HM-08 Felt Paper

HM-09 Chimney Flashing

Roof

Page 13: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

LABORATORY RESULTS

Page 14: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

EMSL Analytical, Inc.706 Gralin Street Kernersville, NC 27284

Tel/Fax: (336) 992-1025 / (336) 992-4175

http://www.EMSL.com / [email protected]

021902219EMSL Order:

Customer ID: ESE52

Customer PO:

Project ID:

Attention: Phone:Jeff Rivers (803) 345-3833

Fax:ABS Environmental (803) 345-2823

Received Date:1416 Chapin Road 04/05/2019 9:15 AM

Analysis Date:Chapin, SC 29036 04/05/2019 - 04/06/2019

Collected Date: 04/04/2019

Project: 63 Downing

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

63-01

021902219-0001

None DetectedCa Carbonate

Non-fibrous (Other)

20%

78%

Cellulose2%White

Non-Fibrous

Homogeneous

Ceiling Texture

63-02

021902219-0002

None DetectedCa Carbonate

Non-fibrous (Other)

20%

78%

Cellulose2%White

Non-Fibrous

Homogeneous

Ceiling Texture

63-03

021902219-0003

None DetectedCa Carbonate

Non-fibrous (Other)

20%

78%

Cellulose2%White

Non-Fibrous

Homogeneous

Ceiling Texture

63-04-Sheetrock

021902219-0004

None DetectedNon-fibrous (Other)90%Cellulose10%Brown/Gray

Fibrous

Homogeneous

Sheetrock/Joint

Compound

63-04-Joint Compound

021902219-0004A

3% ChrysotileCa Carbonate

Non-fibrous (Other)

30%

67%

Tan

Non-Fibrous

Homogeneous

Sheetrock/Joint

Compound

63-05-Sheetrock

021902219-0005

None DetectedNon-fibrous (Other)90%Cellulose10%Brown/Gray

Fibrous

Homogeneous

Sheetrock/Joint

Compound

63-05-Joint Compound

021902219-0005A

2% ChrysotileCa Carbonate

Non-fibrous (Other)

30%

68%

Tan/White

Non-Fibrous

Homogeneous

Sheetrock/Joint

Compound

63-06-Sheetrock

021902219-0006

None DetectedNon-fibrous (Other)90%Cellulose10%Brown/Gray

Fibrous

Heterogeneous

Sheetrock/Joint

Compound

63-06-Joint Compound

021902219-0006A

2% ChrysotileCa Carbonate

Non-fibrous (Other)

20%

78%

White/Beige

Non-Fibrous

Homogeneous

Sheetrock/Joint

Compound

63-07

021902219-0007

<1% ChrysotileCa Carbonate

Non-fibrous (Other)

30%

70%

Tan/White

Non-Fibrous

Homogeneous

Sheetrock/Joint

Compound

63-08

021902219-0008

2% ChrysotileCa Carbonate

Non-fibrous (Other)

20%

78%

White/Beige

Non-Fibrous

Homogeneous

Sheetrock/Joint

Compound

63-09

021902219-0009

None DetectedQuartz

Non-fibrous (Other)

30%

70%

Cellulose<1%Tan

Non-Fibrous

Homogeneous

Ceramic Tile Thinset

63-10

021902219-0010

None DetectedQuartz

Non-fibrous (Other)

30%

70%

Cellulose<1%Tan

Non-Fibrous

Homogeneous

Ceramic Tile Thinset

63-11

021902219-0011

None DetectedQuartz

Non-fibrous (Other)

30%

70%

Cellulose<1%Tan

Non-Fibrous

Homogeneous

Ceramic Tile Thinset

63-12

021902219-0012

55% ChrysotileNon-fibrous (Other)25%Cellulose20%Gray

Fibrous

Homogeneous

Duct Tape

63-13

021902219-0013

60% ChrysotileNon-fibrous (Other)20%Cellulose20%Gray

Fibrous

Homogeneous

Duct Tape

Initial report from: 04/08/2019 08:33:37

Page 1 of 2ASB_PLM_0008_0001 - 1.78 Printed: 4/8/2019 8:33 AM

Page 15: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

EMSL Analytical, Inc.706 Gralin Street Kernersville, NC 27284

Tel/Fax: (336) 992-1025 / (336) 992-4175

http://www.EMSL.com / [email protected]

021902219EMSL Order:

Customer ID: ESE52

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

63-15

021902219-0014

None DetectedCa Carbonate

Non-fibrous (Other)

5%

95%

White

Non-Fibrous

Homogeneous

Exterior Caulk

63-16

021902219-0015

None DetectedCa Carbonate

Non-fibrous (Other)

5%

95%

White

Non-Fibrous

Homogeneous

Exterior Caulk

63-18

021902219-0016

None DetectedNon-fibrous (Other)92%Glass8%Brown/Black

Fibrous

Homogeneous

Roof Shingles

63-19

021902219-0017

None DetectedNon-fibrous (Other)92%Glass8%Brown/Black

Fibrous

Heterogeneous

Roof Shingles

63-21

021902219-0018

None DetectedNon-fibrous (Other)35%Cellulose65%Black

Fibrous

Homogeneous

Felt Paper

63-22

021902219-0019

None DetectedNon-fibrous (Other)30%Cellulose70%Black

Fibrous

Homogeneous

Felt Paper

63-24

021902219-0020

None DetectedNon-fibrous (Other)99%Fibrous (Other)1%Brown/Black

Non-Fibrous

Homogeneous

Chimney Flashing

63-25

021902219-0021

None DetectedNon-fibrous (Other)99%Cellulose

Fibrous (Other)

<1%

1%

Brown/Black

Non-Fibrous

Homogeneous

Chimney Flashing

63-27

021902219-0022

None DetectedNon-fibrous (Other)50%Cellulose

Glass

40%

10%

Brown/Black

Fibrous

Homogeneous

Wire Insulation

63-28

021902219-0023

None DetectedNon-fibrous (Other)50%Cellulose

Glass

40%

10%

Brown/Black

Fibrous

Homogeneous

Wire Insulation

63-29

021902219-0024

None DetectedNon-fibrous (Other)50%Cellulose

Glass

40%

10%

Brown/Black

Fibrous

Homogeneous

Wire Insulation

Analyst(s)

Kristie Elliott (16)

Nicole Shutts (11)

Stephen Bennett, Laboratory Manager

or Other Approved Signatory

EMSL maintains liability limited to cost of analysis . The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 "Interim

Method"), but augmented with procedures outlined in the 1993 ("final") version of the method. This report relates only to the samples reported above, and may not be reproduced, except in full, without

written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . Interpretation and use of test results are the responsibility of the client. All

samples received in acceptable condition unless otherwise noted. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of

the federal government. EMSL recommends gravimetric reduction for all non -friable organically bound materials prior to analysis. Estimation of uncertainty is available on request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC NVLAP Lab Code 102104-0, CA ELAP 2689, Virginia 3333-000228, West Virginia LT000321

Initial report from: 04/08/2019 08:33:37

Page 2 of 2ASB_PLM_0008_0001 - 1.78 Printed: 4/8/2019 8:33 AM

Page 16: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

EMSL Analytical, Inc.706 Gralin Street Kernersville, NC 27284

Tel/Fax: (336) 992-1025 / (336) 992-4175

http://www.EMSL.com / [email protected]

EMSL Order: 021902219

Customer ID: ESE52

Customer PO:

Project ID:

Attention: Jeff Rivers Phone: (803) 345-3833

ABS Environmental Fax: (803) 345-2823

1416 Chapin Road Received Date: 04/05/2019 9:15 AM

Chapin, SC 29036 Analysis Date: 04/08/2019

Collected Date: 04/04/2019

63 DowningProject:

Test Report: Asbestos Analysis of Non-Friable Organically Bound Materials by TEM via

EPA/600/R-93/116 Section 2.5.5.1

Sample ID Description Appearance % Matrix Material % Non-Asbestos Fibers Asbestos Types

63-17

021902219-0025

Exterior Caulk Tan/White

Non-Fibrous

Heterogeneous

100.0 None No Asbestos DetectedOther

63-20

021902219-0026

Roof Shingles Gray/Black/Beige

Fibrous

Heterogeneous

100.0 None No Asbestos DetectedOther

63-23

021902219-0027

Felt Paper Black

Fibrous

Homogeneous

100.0 None No Asbestos DetectedOther

63-26

021902219-0028

Chimney Flashing Black

Non-Fibrous

Homogeneous

100.0 None No Asbestos DetectedOther

Analyst(s)

Stephen Bennett (4) Stephen Bennett, Laboratory Manager

or other approved signatory

This laboratory is not responsible for % asbestos in total sample when the residue only is submitted for analysis. The above report relates only to the items tested. This report may not be reproduced,

except in full, without written approval by EMSL Analytical , Inc. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with

multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC

Initial report from: 04/08/2019 11:38:44

ASB_PLMEPANOB_0012_0002 Printed 4/8/2019 11:38:51AM Page 1 of 1

Page 17: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

OrderID: 021902219

Page 1 Of 2

Page 18: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

OrderID: 021902219

Page 2 Of 2

Page 19: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

April 15, 2019

Asbestos Survey For

87 Downing Street, Columbia, SC

Prepared for: City of Columbia Phone: (803) 545-3444 Attn: David Hatcher

1136 Washington Street Columbia, SC 29201 Prepared by: ABS Environmental, Inc. Phone: (803) 345-3833

1416 Chapin Road Chapin, SC 29036

ABS Job # 7800.19012

Inspection Performed by:

SCDHEC # Lic Exp Date Jeff Rivers MP – 00166 8/1/19

Report Prepared by:

SCDHEC # Lic Exp Date Jeff Rivers MP – 00166 8/1/19

Report Reviewed by:

SCDHEC # Lic Exp Date Lee Capell MP – 00072 8/8/19

Page 20: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

87 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19012

TABLE OF CONTENTS

1.0 EXECUTIVE SUMMARY

2.0 APPENDIX

A. Drawing

B. Site Map

C. Tables

D. Laboratory Results

Page 21: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

87 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19012

1.0 EXECUTIVE SUMMARY

ABS Environmental, Inc. (ABS) was retained by the City of Columbia to perform an asbestos survey at 87 Downing Street in Columbia, SC. The primary objective of this survey was to identify, sample and physically assess suspect asbestos-containing building materials (ACBM) associated with the vacant residence. The subject structure is an approximately 897 ft2 single-family residence built over a crawlspace. The roof is built in a gabled configuration and is covered with 3-tab composition shingles. The exterior is clad with a cementitious siding. Interior finishes include: Ceilings/Walls: Sheetrock throughout. Floors: Combination of hardwood and vinyl. Eighteen (18) suspect materials were identified, sampled and analyzed for the presence of asbestos. Samples were delivered by overnight courier service to EMSL Analytical, Inc. for analysis using Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM) to confirm negative PLM results for non-friable organically bound materials. As indicated by laboratory analysis, those materials containing asbestos > 1 % include approximately 1,488 ft2 of exterior siding. Limitations This survey and report have been executed at the request of Mr. David Hatcher and City of Columbia and are intended solely for their use. All work related to this project has been conducted in keeping with accepted standards of environmental consulting as practiced in the State of South Carolina. No unnecessary destructive measures were undertaken during this survey. Additional suspect and/or asbestos containing materials may be present. If at any time during the course of renovation or demolition a suspect material is observed that is not identified in this report, stop work immediately until the material can be sampled and analyzed for the presence of asbestos. ABS has relied, in part, on information derived from secondary sources, and except as set forth herein, ABS has made no independent investigation as to the accuracy or completeness of the information derived from such secondary sources. No warranty is expressed or implied.

Page 22: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

87 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19012

DRAWINGS

Page 23: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011
Page 24: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

87 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19012

SITE MAP

Page 25: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

87 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19012

TABLES

Page 26: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Date:

* Assumed to Contain Asbestos > 1%

1,488 ft2

Table #1Asbestos Containing Building Material (ACBM)

Project Name: 87 Downing StreetProject Address: 87 Downing St., Columbia, SC 15-Apr-19

Observed ACBMMaterial EPA AHERA Category Quantity

Exterior Siding Miscellaneous

Page 27: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Date:

* Assumed to Contain Asbestos > 1%

Non-Friable ACBMMaterial Quantity

Exterior Siding 1,488 ft2

Table #2Non-Friable ACBM

Project Name: 87 Downing StreetProject Address: 87 Downing St., Columbia, SC 15-Apr-19

Page 28: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Date:

F = Friable NF= Non Friable

G = Good (Very localized damage)

S = Surfacing Material (Spray-applied or trowel applied)

Suspect Material Category # Present Disturbance P or N P or N P or N HazardMaterial # Description (S, T, M) Samples Condition Potential PLM TEM Point Count Ranking

HM-01 Sheetrock M 5 2,242 ft2 F/G PD N NAHM-02 Joint Compound S 5 2,242 ft2 F/G PD N NAHM-03 1' x 1' Ceiling Tile M 3 897 ft2 F/G PD N NAHM-04 Mastic above HM-03 M 3 897 ft2 NF/G LPD N N NA

HM-05Kitchen Sheet Vinyl

(Beige Flooring)M 3 164 ft2 NF/G PD N N NA

HM-06 Mastic below HM-05 M 3 164 ft2 NF/G LPD N N NA

HM-07Kitchen Sheet Vinyl

(Tan Flooring)M 3 164 ft2 NF/G LPD N N NA

HM-08 Mastic below HM-07 M 3 164 ft2 NF/G LPD N N NA

HM-09 Bathroom Sheet Vinyl M 3 40 ft2 NF/G PD N N NA

87 Downing Street

Table #3Asbestos - Suspect Material Data Sheet

Project Name:

PD = Potential for Damage (Any One Mechanism of Moderate Concern)

LPD = Low Potential for Disturbance (All Three Mechanisms of Low Concern)

PTP = Previously tested Positive

PTN = Previously tested Negative

Quantity

P = Positive via PLM

P = Positive via TEM

N = Negative: does not meet definition of ACM

A = Assumed to be ACM; no samples collected

Present Condition

SD = Significantly Damaged (Damage equal to or greater than 10 % distributed/ 25 % localized)

D = Damaged (Damage less than 10 distributed and less than 25 % localized)

M = Miscellaneous Materials (Refer to as "Other" materials by OSHA)

T = Thermal System Insulation (Inhibits heat transfer or prohibits condensation)

of High Concern or More Than One of Moderate Concern)

PSD = Potential for Significant Damage (One Mechanism

Potential for Future Disturbance by Contact, Vibration or Air Erosion Mechanisms

EPA AHERA Asbestos Category

Hazard Ranking = 7 thru 1; (7 being the worst i.e. significantly damaged material)

Asbestos Finding; Asbestos Containing Material (ACM) contains > 1% asbestos by definition

Project Address: 15-Apr-1987 Downing St., Columbia, SC

Page 29: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Date:

F = Friable NF= Non Friable

G = Good (Very localized damage)

S = Surfacing Material (Spray-applied or trowel applied)

Suspect Material Category # Present Disturbance P or N P or N P or N HazardMaterial # Description (S, T, M) Samples Condition Potential PLM TEM Point Count Ranking

87 Downing Street

Table #3Asbestos - Suspect Material Data Sheet

Project Name:

PD = Potential for Damage (Any One Mechanism of Moderate Concern)

LPD = Low Potential for Disturbance (All Three Mechanisms of Low Concern)

PTP = Previously tested Positive

PTN = Previously tested Negative

Quantity

P = Positive via PLM

P = Positive via TEM

N = Negative: does not meet definition of ACM

A = Assumed to be ACM; no samples collected

Present Condition

SD = Significantly Damaged (Damage equal to or greater than 10 % distributed/ 25 % localized)

D = Damaged (Damage less than 10 distributed and less than 25 % localized)

M = Miscellaneous Materials (Refer to as "Other" materials by OSHA)

T = Thermal System Insulation (Inhibits heat transfer or prohibits condensation)

of High Concern or More Than One of Moderate Concern)

PSD = Potential for Significant Damage (One Mechanism

Potential for Future Disturbance by Contact, Vibration or Air Erosion Mechanisms

EPA AHERA Asbestos Category

Hazard Ranking = 7 thru 1; (7 being the worst i.e. significantly damaged material)

Asbestos Finding; Asbestos Containing Material (ACM) contains > 1% asbestos by definition

Project Address: 15-Apr-1987 Downing St., Columbia, SC

HM-10 Mastic below HM-09 M 3 40 ft2 NF/G LPD N N NA

HM-11Felt Paper Under Hardwood Floors

M 3 693 ft2 NF/G LPD N N NA

HM-12 Ext Window Glazing M 3 3 windows NF/G PD N N NAHM-13 Exterior Caulk M 3 2 doors;

8 windows NF/G PD N N NAHM-14 Exterior Siding M 3 1,488 ft2 NF/G PD P 2

HM-15Felt Paper Behind HM-

14M 3 1,488 ft2 NF/G LPD N N NA

HM-16 Roof Shingles M 3 1,495 ft2 NF/G PD N N NA

HM-17Felt Paper Under HM-

16M 3 1,495 ft2 NF/G LPD N N NA

HM-18 Chimney Flashing M 3 10 LF NF/G PD N N NA

Page 30: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

* NAD = No Asbestos Detected Amos = Amosite

DNA = Did Not Analyze Croc = Crocidilite

Chry = ChrysotileAnth = Anthophylite

Date:

Assumed to contain Asbestos > 1%

Laboratory ABS Suspect Material Type * Percent Percent PercentSample # Sample # Material # Description Asbestos PLM TEM Point Count

021902204-0001 87-01 Living Room NAD021902204-0002 87-02 Kitchen NAD021902204-0003 87-03 Bedroom 3 NAD021902204-0004 87-04 Bathroom NAD021902204-0005 87-05 Master Bedroom NAD

021902204-0001A 87-01 Living Room NAD021902204-0002A 87-02 Kitchen NAD021902204-0003A 87-03 Bedroom 3 NAD021902204-0004A 87-04 Bathroom NAD021902204-0005A 87-05 Master Bedroom NAD021902204-0006 87-06 Kitchen NAD021902204-0007 87-07 Bedroom 2 NAD021902204-0008 87-08 Hallway NAD

021902204-0006A 87-06 Kitchen NAD021902204-0007A 87-07 Bedroom 2 NAD021902204-0008A 87-08 Hallway NAD NAD021902204-0009 87-09 NAD021902204-0010 87-10 NAD021902204-0030 87-11 NAD

021902204-0009A 87-09 NAD021902204-0010A 87-10 NAD021902204-0031 87-11 NAD

Location

Joint CompoundHM-02

HM-01 Sheetrock

HM-06 Mastic below HM-05

Table #4Asbestos - Bulk Sample Data Sheet

Project Name:Project Address:

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via PLM

87 Downing Street87 Downing St., Columbia, SC 15-Apr-19

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via TEM

* Chry = Chrysotile Amos = Amosite Croc = Crocidolite Anth = Anthophylite NAD = No Asbestos Detected DNA = Did Not Analyze

HM-04 Mastic above HM-03

1' x 1' Ceiling TileHM-03

HM-05Sheet Vinyl

(Beige Flooring)Kitchen

Kitchen

Page 31: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

* NAD = No Asbestos Detected Amos = Amosite

DNA = Did Not Analyze Croc = Crocidilite

Chry = ChrysotileAnth = Anthophylite

Date:

Assumed to contain Asbestos > 1%

Laboratory ABS Suspect Material Type * Percent Percent PercentSample # Sample # Material # Description Asbestos PLM TEM Point Count

Location

Table #4Asbestos - Bulk Sample Data Sheet

Project Name:Project Address:

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via PLM

87 Downing Street87 Downing St., Columbia, SC 15-Apr-19

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via TEM

* Chry = Chrysotile Amos = Amosite Croc = Crocidolite Anth = Anthophylite NAD = No Asbestos Detected DNA = Did Not Analyze

021902204-0009B 87-09 NAD021902204-0010B 87-10 NAD021902204-0032 87-11 NAD

021902204-0009C 87-09 NAD021902204-0010C 87-10 NAD021902204-0033 87-11 NAD021902204-0011 87-12 NAD021902204-0012 87-13 NAD021902204-0034 87-14 NAD

021902204-0011A 87-12 NAD021902204-0012A 87-13 NAD021902204-0035 87-14 NAD021902204-0013 87-15 Living Room NAD021902204-0014 87-16 Hallway NAD021902204-0036 87-17 Bedroom 3 NAD021902204-0015 87-18 NAD021902204-0016 87-19 NAD021902204-0037 87-20 NAD021902204-0017 87-21 NAD021902204-0018 87-22 NAD021902204-0038 87-23 NAD

HM-08 Mastic below HM-07

HM-09 Sheet Vinyl

Kitchen

Kitchen

Sheet Vinyl (Tan Flooring)

HM-07

HM-13 Exterior Caulk

HM-10 Mastic below HM-09

HM-11Felt Paper Under Hardwood Floors

HM-12 Exterior Window Glazing

Bathroom

Bathroom

Page 32: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

* NAD = No Asbestos Detected Amos = Amosite

DNA = Did Not Analyze Croc = Crocidilite

Chry = ChrysotileAnth = Anthophylite

Date:

Assumed to contain Asbestos > 1%

Laboratory ABS Suspect Material Type * Percent Percent PercentSample # Sample # Material # Description Asbestos PLM TEM Point Count

Location

Table #4Asbestos - Bulk Sample Data Sheet

Project Name:Project Address:

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via PLM

87 Downing Street87 Downing St., Columbia, SC 15-Apr-19

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via TEM

* Chry = Chrysotile Amos = Amosite Croc = Crocidolite Anth = Anthophylite NAD = No Asbestos Detected DNA = Did Not Analyze

021902204-0019 87-24 Chry 15%021902204-0020 87-25 Chry 15%021902204-0021 87-26 Chry 15%021902204-0022 87-27 NAD021902204-0023 87-28 NAD021902204-0039 87-29 NAD021902204-0024 87-30 NAD021902204-0025 87-31 NAD021902204-0040 87-32 NAD021902204-0026 87-33 NAD021902204-0027 87-34 NAD021902204-0041 87-35 NAD021902204-0028 87-36 NAD021902204-0029 87-37 NAD021902204-0042 87-38 NAD

HM-14 Exterior Siding

Roof

HM-18 Chimney Flashing

HM-15Felt Paper Behind

HM-14

HM-16 Shingles

HM-17Felt Paper Under

HM-16

Roof

Page 33: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

87 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19012

LABORATORY RESULTS

Page 34: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

EMSL Analytical, Inc.706 Gralin Street Kernersville, NC 27284

Tel/Fax: (336) 992-1025 / (336) 992-4175

http://www.EMSL.com / [email protected]

021902204EMSL Order:

Customer ID: ESE52

Customer PO:

Project ID:

Attention: Phone:Jeff Rivers (803) 345-3833

Fax:ABS Environmental (803) 345-2823

Received Date:1416 Chapin Road 04/05/2019 10:00 AM

Analysis Date:Chapin, SC 29036 04/05/2019

Collected Date: 04/04/2019

Project: 87 Downing

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

87-01-Sheetrock

021902204-0001

None DetectedNon-fibrous (Other)85%Cellulose15%Brown/Gray

Fibrous

Heterogeneous

Sheetrock/Joint

Compound

87-01-Joint Compound

021902204-0001A

None DetectedCa Carbonate

Non-fibrous (Other)

30%

70%

Cellulose<1%White

Non-Fibrous

Homogeneous

Sheetrock/Joint

Compound

87-02-Sheetrock

021902204-0002

None DetectedNon-fibrous (Other)90%Cellulose10%Brown/Gray

Fibrous

Heterogeneous

Sheetrock/Joint

Compound

87-02-Joint Compound

021902204-0002A

None DetectedCa Carbonate

Non-fibrous (Other)

30%

70%

Cellulose<1%White

Non-Fibrous

Homogeneous

Sheetrock/Joint

Compound

87-03-Sheetrock

021902204-0003

None DetectedNon-fibrous (Other)85%Cellulose15%Brown/Gray

Fibrous

Heterogeneous

Sheetrock/Joint

Compound

87-03-Joint Compound

021902204-0003A

None DetectedCa Carbonate

Non-fibrous (Other)

30%

70%

Cellulose<1%White

Non-Fibrous

Homogeneous

Sheetrock/Joint

Compound

87-04-Sheetrock

021902204-0004

None DetectedNon-fibrous (Other)90%Cellulose10%Brown/Gray

Fibrous

Heterogeneous

Sheetrock/Joint

Compound

87-04-Joint Compound

021902204-0004A

None DetectedCa Carbonate

Non-fibrous (Other)

30%

70%

Cellulose<1%White

Non-Fibrous

Homogeneous

Sheetrock/Joint

Compound

87-05-Sheetrock

021902204-0005

None DetectedNon-fibrous (Other)85%Cellulose15%Brown/Gray

Fibrous

Heterogeneous

Sheetrock/Joint

Compound

87-05-Joint Compound

021902204-0005A

None DetectedCa Carbonate

Non-fibrous (Other)

30%

69%

Cellulose1%White

Non-Fibrous

Homogeneous

Sheetrock/Joint

Compound

87-06-Ceiling Tile

021902204-0006

None DetectedPerlite

Non-fibrous (Other)

3%

2%

Cellulose95%Brown/White

Fibrous

Homogeneous

1x1 Ceiling tile

87-06-Mastic

021902204-0006A

None DetectedNon-fibrous (Other)100%Cellulose<1%Brown

Non-Fibrous

Homogeneous

1x1 Ceiling tile

87-07-Ceiling Tile

021902204-0007

None DetectedPerlite

Non-fibrous (Other)

3%

2%

Cellulose95%Brown/White

Fibrous

Homogeneous

1x1 Ceiling tile

87-07-Mastic

021902204-0007A

None DetectedNon-fibrous (Other)100%Cellulose<1%Brown

Non-Fibrous

Homogeneous

1x1 Ceiling tile

87-08-Ceiling Tile

021902204-0008

None DetectedPerlite

Non-fibrous (Other)

3%

2%

Cellulose95%Brown/White

Fibrous

Homogeneous

1x1 Ceiling tile

87-08-Mastic

021902204-0008A

None DetectedNon-fibrous (Other)100%Cellulose<1%Brown

Non-Fibrous

Homogeneous

1x1 Ceiling tile

Initial report from: 04/05/2019 17:13:22

Page 1 of 3ASB_PLM_0008_0001 - 1.78 Printed: 4/5/2019 5:13 PM

Page 35: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

EMSL Analytical, Inc.706 Gralin Street Kernersville, NC 27284

Tel/Fax: (336) 992-1025 / (336) 992-4175

http://www.EMSL.com / [email protected]

021902204EMSL Order:

Customer ID: ESE52

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

87-09-Beige Flooring

021902204-0009

None DetectedNon-fibrous (Other)79%Cellulose

Glass

20%

1%

Beige

Fibrous

Heterogeneous

Kitchen Sheet Vinyl

87-09-Mastic

021902204-0009A

None DetectedNon-fibrous (Other)100%Cellulose<1%Tan

Non-Fibrous

Homogeneous

Kitchen Sheet Vinyl

87-09-Tan Flooring

021902204-0009B

None DetectedNon-fibrous (Other)79%Cellulose

Glass

20%

1%

Gray/Tan

Fibrous

Heterogeneous

Kitchen Sheet Vinyl

87-09-Mastic 2

021902204-0009C

None DetectedNon-fibrous (Other)100%Cellulose<1%Tan

Non-Fibrous

Homogeneous

Kitchen Sheet Vinyl

87-10-Beige Flooring

021902204-0010

None DetectedNon-fibrous (Other)84%Cellulose

Glass

15%

1%

Gray/Beige

Fibrous

Heterogeneous

Kitchen Sheet Vinyl

87-10-Mastic

021902204-0010A

None DetectedNon-fibrous (Other)99%Cellulose1%Tan/Yellow

Non-Fibrous

Homogeneous

Kitchen Sheet Vinyl

87-10-Tan Flooring

021902204-0010B

None DetectedNon-fibrous (Other)74%Cellulose

Glass

25%

1%

Brown/Gray/Tan

Fibrous

Heterogeneous

Kitchen Sheet Vinyl

87-10-Mastic 2

021902204-0010C

None DetectedNon-fibrous (Other)99%Cellulose1%Yellow/Gold

Non-Fibrous

Homogeneous

Kitchen Sheet Vinyl

87-12-Flooring

021902204-0011

None DetectedNon-fibrous (Other)85%Cellulose15%Tan/Beige

Fibrous

Heterogeneous

Bathroom Sheet Vinyl

87-12-Mastic

021902204-0011A

None DetectedNon-fibrous (Other)100%Cellulose<1%Tan

Non-Fibrous

Homogeneous

Bathroom Sheet Vinyl

87-13-Flooring

021902204-0012

None DetectedNon-fibrous (Other)84%Cellulose

Glass

15%

1%

Brown/Gray/Tan

Fibrous

Heterogeneous

Bathroom Sheet Vinyl

87-13-Mastic

021902204-0012A

None DetectedNon-fibrous (Other)99%Cellulose1%Yellow/Beige

Non-Fibrous

Homogeneous

Bathroom Sheet Vinyl

87-15

021902204-0013

None DetectedNon-fibrous (Other)30%Cellulose70%Black

Fibrous

Homogeneous

Felt Paper Under

Hardwood Floors

87-16

021902204-0014

None DetectedNon-fibrous (Other)30%Cellulose

Synthetic

70%

<1%

Black

Fibrous

Homogeneous

Felt Paper Under

Hardwood Floors

87-18

021902204-0015

None DetectedCa Carbonate

Non-fibrous (Other)

10%

90%

Cellulose

Fibrous (Other)

<1%

<1%

Gray/Tan/White

Non-Fibrous

Homogeneous

Exterior Window

Glazing

87-19

021902204-0016

None DetectedCa Carbonate

Non-fibrous (Other)

10%

90%

Cellulose

Fibrous (Other)

<1%

<1%

Gray/Tan/White

Non-Fibrous

Homogeneous

Exterior Window

Glazing

87-21

021902204-0017

None DetectedCa Carbonate

Non-fibrous (Other)

10%

90%

Cellulose<1%White

Non-Fibrous

Homogeneous

Exterior Caulk

87-22

021902204-0018

None DetectedCa Carbonate

Non-fibrous (Other)

10%

88%

Cellulose2%White/Beige

Non-Fibrous

Homogeneous

Exterior Caulk

87-24

021902204-0019

15% ChrysotileNon-fibrous (Other)85%Gray/White

Fibrous

Homogeneous

Exterior Siding

Initial report from: 04/05/2019 17:13:22

Page 2 of 3ASB_PLM_0008_0001 - 1.78 Printed: 4/5/2019 5:13 PM

Page 36: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

EMSL Analytical, Inc.706 Gralin Street Kernersville, NC 27284

Tel/Fax: (336) 992-1025 / (336) 992-4175

http://www.EMSL.com / [email protected]

021902204EMSL Order:

Customer ID: ESE52

Customer PO:

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

87-25

021902204-0020

15% ChrysotileNon-fibrous (Other)85%Gray/White

Fibrous

Homogeneous

Exterior Siding

87-26

021902204-0021

15% ChrysotileNon-fibrous (Other)85%Cellulose<1%Gray/White/Beige

Fibrous

Homogeneous

Exterior Siding

87-27

021902204-0022

None DetectedNon-fibrous (Other)30%Cellulose70%Black

Fibrous

Homogeneous

Felt Paper Behind

Siding

87-28

021902204-0023

None DetectedNon-fibrous (Other)30%Cellulose

Synthetic

70%

<1%

Black

Fibrous

Homogeneous

Felt Paper Behind

Siding

87-30

021902204-0024

None DetectedNon-fibrous (Other)92%Glass8%Gray/White/Black

Fibrous

Heterogeneous

Roof Shingles

87-31

021902204-0025

None DetectedNon-fibrous (Other)92%Cellulose

Glass

<1%

8%

White/Black

Fibrous

Heterogeneous

Roof Shingles

87-33

021902204-0026

None DetectedNon-fibrous (Other)30%Cellulose70%Black

Fibrous

Homogeneous

Felt Paper Under

Roof Shingles

87-34

021902204-0027

None DetectedNon-fibrous (Other)30%Cellulose70%Black

Fibrous

Homogeneous

Felt Paper Under

Roof Shingles

87-36

021902204-0028

None DetectedNon-fibrous (Other)99%Cellulose

Fibrous (Other)

<1%

1%

Gray/Black

Non-Fibrous

Homogeneous

Chimney Flashing

87-37

021902204-0029

None DetectedNon-fibrous (Other)98%Cellulose

Fibrous (Other)

1%

1%

Black

Non-Fibrous

Homogeneous

Chimney Flashing

Analyst(s)

Nicole Shutts (27)

Scott Combs (18)

Stephen Bennett, Laboratory Manager

or Other Approved Signatory

EMSL maintains liability limited to cost of analysis . The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 "Interim

Method"), but augmented with procedures outlined in the 1993 ("final") version of the method. This report relates only to the samples reported above, and may not be reproduced, except in full, without

written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . Interpretation and use of test results are the responsibility of the client. All

samples received in acceptable condition unless otherwise noted. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of

the federal government. EMSL recommends gravimetric reduction for all non -friable organically bound materials prior to analysis. Estimation of uncertainty is available on request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC NVLAP Lab Code 102104-0, CA ELAP 2689, Virginia 3333-000228, West Virginia LT000321

Initial report from: 04/05/2019 17:13:22

Page 3 of 3ASB_PLM_0008_0001 - 1.78 Printed: 4/5/2019 5:13 PM

Page 37: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

EMSL Analytical, Inc.706 Gralin Street Kernersville, NC 27284

Tel/Fax: (336) 992-1025 / (336) 992-4175

http://www.EMSL.com / [email protected]

EMSL Order: 021902204

Customer ID: ESE52

Customer PO:

Project ID:

Attention: Jeff Rivers Phone: (803) 345-3833

ABS Environmental Fax: (803) 345-2823

1416 Chapin Road Received Date: 04/05/2019 10:00 AM

Chapin, SC 29036 Analysis Date: 04/08/2019

Collected Date: 04/04/2019

87 DowningProject:

Test Report: Asbestos Analysis of Non-Friable Organically Bound Materials by TEM via

EPA/600/R-93/116 Section 2.5.5.1

Sample ID Description Appearance % Matrix Material % Non-Asbestos Fibers Asbestos Types

87-08-Mastic

021902204-0008A

1x1 Ceiling tile Brown

Fibrous

Homogeneous

100.0 None No Asbestos DetectedOther

87-11-Beige Flooring

021902204-0030

Kitchen Sheet Vinyl Beige

Fibrous

Heterogeneous

100.0 None No Asbestos DetectedOther

87-11-Mastic

021902204-0031

Kitchen Sheet Vinyl Tan

Non-Fibrous

Homogeneous

100.0 None No Asbestos DetectedOther

87-11-Tan Flooring

021902204-0032

Kitchen Sheet Vinyl Tan

Fibrous

Heterogeneous

100.0 None No Asbestos DetectedOther

87-11-Mastic 2

021902204-0033

Kitchen Sheet Vinyl Tan

Non-Fibrous

Homogeneous

100.0 None No Asbestos DetectedOther

87-14-Flooring

021902204-0034

Bathroom Sheet Vinyl Tan

Fibrous

Heterogeneous

100.0 None No Asbestos DetectedOther

87-14-Mastic

021902204-0035

Bathroom Sheet Vinyl Tan

Non-Fibrous

Homogeneous

100.0 None No Asbestos DetectedOther

87-17

021902204-0036

Felt Paper Under

Hardwood Floors

Black

Fibrous

Homogeneous

100.0 None No Asbestos DetectedOther

87-20

021902204-0037

Exterior Window Glazing White

Non-Fibrous

Heterogeneous

100.0 None No Asbestos DetectedOther

87-23

021902204-0038

Exterior Caulk White/Beige

Non-Fibrous

Heterogeneous

100.0 None No Asbestos DetectedOther

87-29

021902204-0039

Felt Paper Behind Siding Black

Fibrous

Homogeneous

100.0 None No Asbestos DetectedOther

87-32

021902204-0040

Roof Shingles White/Black

Fibrous

Heterogeneous

100.0 None No Asbestos DetectedOther

This laboratory is not responsible for % asbestos in total sample when the residue only is submitted for analysis. The above report relates only to the items tested. This report may not be reproduced,

except in full, without written approval by EMSL Analytical , Inc. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with

multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC

Initial report from: 04/08/2019 13:47:23

ASB_PLMEPANOB_0012_0002 Printed 4/8/2019 1:47:29PM Page 1 of 2

Page 38: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

EMSL Analytical, Inc.706 Gralin Street Kernersville, NC 27284

Tel/Fax: (336) 992-1025 / (336) 992-4175

http://www.EMSL.com / [email protected]

EMSL Order: 021902204

Customer ID: ESE52

Customer PO:

Project ID:

Attention: Jeff Rivers Phone: (803) 345-3833

ABS Environmental Fax: (803) 345-2823

1416 Chapin Road Received Date: 04/05/2019 10:00 AM

Chapin, SC 29036 Analysis Date: 04/08/2019

Collected Date: 04/04/2019

87 DowningProject:

Test Report: Asbestos Analysis of Non-Friable Organically Bound Materials by TEM via

EPA/600/R-93/116 Section 2.5.5.1

Sample ID Description Appearance % Matrix Material % Non-Asbestos Fibers Asbestos Types

87-35

021902204-0041

Felt Paper Under Roof

Shingles

Black

Fibrous

Homogeneous

100.0 None No Asbestos DetectedOther

87-38

021902204-0042

Chimney Flashing Black

Non-Fibrous

Homogeneous

100.0 None No Asbestos DetectedOther

Analyst(s)

Stephen Bennett (14) Stephen Bennett, Laboratory Manager

or other approved signatory

This laboratory is not responsible for % asbestos in total sample when the residue only is submitted for analysis. The above report relates only to the items tested. This report may not be reproduced,

except in full, without written approval by EMSL Analytical , Inc. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with

multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC

Initial report from: 04/08/2019 13:47:23

ASB_PLMEPANOB_0012_0002 Printed 4/8/2019 1:47:29PM Page 2 of 2

Page 39: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

OrderID: 021902204

Page 1 Of 2

Page 40: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

OrderID: 021902204

Page 2 Of 2

Page 41: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Prepared

Prepared

Inspectio

Report P

Report R

d for:

d by:

on Performed

repared by:

Reviewed by

82

City of CoAttn: Dav1136 WasColumbia

ABS Envi1416 ChapChapin, SABS Job #

d by:

:

Mar

Asbes

24 Burwell

olumbiavid Hatchershington Stra, SC 29201

ironmental,pin Road

SC 29036# 7800.1900

Jeff R

Jeff R

Lee C

rch 4, 2019

stos SurvFor

Lane, Colu

reet

, Inc.

05

Rivers

Rivers

Capell

9

vey

mbia, SC

P

P

SCDMP –

SCDMP –

SCDMP –

Phone: (803

Phone: (803

DHEC # – 00166

DHEC # – 00166

DHEC # – 00072

3) 545-3444

3) 345-3833

Lic Exp D8/1/19

Lic Exp D8/1/19

Lic Exp D8/8/19

Date

Date

Date

Page 42: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

824 Burwell Ln ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19005

TABLE OF CONTENTS

1.0 EXECUTIVE SUMMARY

2.0 APPENDIX

A. Drawing

B. Site Map

C. Tables

D. Laboratory Results

Page 43: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

824 Burwell Ln ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19005

1.0 EXECUTIVE SUMMARY

ABS Environmental, Inc. (ABS) was retained by the City of Columbia to perform an asbestos survey at 824 Burwell Lane in Columbia, SC. The primary objective of this survey was to identify, sample and physically assess suspect asbestos-containing building materials (ACBM) associated with the vacant residence. The subject structure is an approximately 1,820 ft2 single-family residence built over a crawlspace. The roof is built in an intersecting hip configuration and is covered with 3-tab composition shingles. The exterior is clad primarily with brick veneer. Interior finishes include: Ceilings/Walls: Sheetrock Ceilings throughout. Sheetrock walls only in the kitchen and bathroom. Everywhere else is just wood framed. Sheetrock dust is located on various surfaces throughout the house. Floors: Combination of ceramic tile and wood floors. Twelve (12) suspect materials were identified, sampled and analyzed for the presence of asbestos. Samples were delivered by overnight courier service to SAI, Inc. for analysis using Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM) to confirm negative PLM results for non-friable organically bound materials. As indicated by laboratory analysis, those materials containing asbestos > 1 % include approximately:

1,820 ft2 of joint compound on the sheetrock ceilings throughout the residence

504 ft2 of joint compound on sheetrock walls in Kitchen and Bathroom

Sheetrock dust throughout the house

Exterior caulk on 5 doors and 3 windows

12 LF of chimney flashing Limitations This survey and report have been executed at the request of Mr. David Hatcher and City of Columbia and are intended solely for their use. All work related to this project has been conducted in keeping with accepted standards of environmental consulting as practiced in the State of South Carolina. No unnecessary destructive measures were undertaken during this survey. Additional suspect and/or asbestos containing materials may be present. If at any time during the course of renovation or demolition a suspect material is observed that is not identified in this report, stop work immediately until the material can be sampled and analyzed for the presence of asbestos. ABS has relied, in part, on information derived from secondary sources, and except as set forth herein, ABS has made no independent investigation as to the accuracy or

Page 44: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

824 Burwell Ln ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19005

completeness of the information derived from such secondary sources. No warranty is expressed or implied.

Page 45: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

824 Burwell Ln ABS Environmental, Inc. Limited Asbestos Survey ABS Job # 7800.19005

DRAWING

Page 46: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011
Page 47: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

824 Burwell Ln ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19005

SITE MAP

Page 48: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

824 Burwell Ln ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19005

TABLES

Page 49: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

*  Assumed to Contain Asbestos > 1%

Observed ACBMMaterial EPA AHERA Category Quantity

Joint Compound (Ceilings) Surfacing 1,820 ft2

Table #1Asbestos Containing Building Material (ACBM)

Project Name: 824 Burwell Lane

Project Address: 824 Burwell Ln., Columbia, SC 4‐Mar‐19

Exterior Caulk Miscellaneous 5 doors; 23 windows

Joint Compound (Walls) Surfacing 504 ft2

Page 50: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

*  Assumed to Contain Asbestos > 1%

Joint Compound (Walls) 504 ft2

Table #2Friable ACBM

Project Name: 824 Burwell Lane

Project Address: 824 Burwell Ln., Columbia, SC 4‐Mar‐19

Friable ACBM

Material Quantity

Joint Compound (Ceilings) 1,820 ft2

Page 51: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

*  Assumed to Contain Asbestos > 1%

Table #3

Non‐Friable ACBM

Project Name: 824 Burwell Lane

Project Address: 824 Burwell Ln., Columbia, SC 4‐Mar‐19

Non‐Friable ACBM

Material Quantity

Exterior Caulk 5 doors; 23 windows

Page 52: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

F = Friable NF= Non Friable

G = Good (Very localized damage)

S = Surfacing Material (Spray‐applied or trowel applied)

Suspect Material Category # Present Disturbance P or N P or N P or N Hazard

Material # Description (S, T, M) Samples Condition Potential PLM TEM Point Count Ranking

HM‐01 Sheetrock  M 3 2,324 ft2 F/G PD N NA

Joint Comp: Ceilings 1,820 ft2

Joint Comp: Walls 504 ft2

HM‐03 Attic Insulation T 3 1,820 ft2 F/G PD N NA

HM‐04 Ceramic Tile Thinset M 3 118 ft2 F/G LPD N NA

HM‐05 Duct Mastic M 3 NF/G PD N N NA

HM‐06Exterior Window 

GlazingM 3 18 windows NF/G PD N N NA

HM‐07 Roof Shingles M 3 2,730 ft2 NF/G PD N N NA

HM‐08 Felt Paper M 3 2,730 ft2 NF/G LPD N N NA

HM‐09 Interior Felt Paper M 3 1,530 ft2 NF/G PD N N NA

Asbestos Finding;                    Asbestos Containing Material (ACM) contains > 1% asbestos by definition

Project Address: 4‐Mar‐19824 Burwell Ln., Columbia, SC

Quantity

P = Positive via PLM

P = Positive via TEM

N = Negative: does not meet definition of ACM

A = Assumed to be ACM; no samples collected

Present Condition

SD = Significantly Damaged (Damage equal to or greater than 10 % distributed/ 25 % localized)

D = Damaged (Damage less than 10 distributed and less than 25 % localized)

M = Miscellaneous Materials (Refer to as "Other" materials by OSHA)

T = Thermal System Insulation (Inhibits heat transfer or prohibits condensation)

of High Concern or More Than One of Moderate Concern)

PSD = Potential for Significant Damage (One Mechanism

Potential for Future Disturbance by Contact, Vibration or Air Erosion Mechanisms

EPA AHERA Asbestos Category

Hazard Ranking  = 7 thru 1; (7 being the worst i.e. significantly damaged material)

824 Burwell Lane

Table #4Asbestos ‐ Suspect Material Data Sheet

Project Name:

PD = Potential for Damage (Any One Mechanism of Moderate Concern)

LPD = Low Potential for Disturbance (All Three Mechanisms of Low Concern) 

PTP = Previously tested Positive

PTN = Previously tested Negative

P 2HM‐02 S 5 F/G PD

Page 53: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

F = Friable NF= Non Friable

G = Good (Very localized damage)

S = Surfacing Material (Spray‐applied or trowel applied)

Suspect Material Category # Present Disturbance P or N P or N P or N Hazard

Material # Description (S, T, M) Samples Condition Potential PLM TEM Point Count Ranking

Asbestos Finding;                    Asbestos Containing Material (ACM) contains > 1% asbestos by definition

Project Address: 4‐Mar‐19824 Burwell Ln., Columbia, SC

Quantity

P = Positive via PLM

P = Positive via TEM

N = Negative: does not meet definition of ACM

A = Assumed to be ACM; no samples collected

Present Condition

SD = Significantly Damaged (Damage equal to or greater than 10 % distributed/ 25 % localized)

D = Damaged (Damage less than 10 distributed and less than 25 % localized)

M = Miscellaneous Materials (Refer to as "Other" materials by OSHA)

T = Thermal System Insulation (Inhibits heat transfer or prohibits condensation)

of High Concern or More Than One of Moderate Concern)

PSD = Potential for Significant Damage (One Mechanism

Potential for Future Disturbance by Contact, Vibration or Air Erosion Mechanisms

EPA AHERA Asbestos Category

Hazard Ranking  = 7 thru 1; (7 being the worst i.e. significantly damaged material)

824 Burwell Lane

Table #4Asbestos ‐ Suspect Material Data Sheet

Project Name:

PD = Potential for Damage (Any One Mechanism of Moderate Concern)

LPD = Low Potential for Disturbance (All Three Mechanisms of Low Concern) 

PTP = Previously tested Positive

PTN = Previously tested Negative

HM‐10Vapor Barrier at 

Exterior WallsM 3 1,530 ft

2 NF/G LPD N N NA

HM‐11 Exterior Caulk M 35 doors; 

3 windowsNF/G PD N P 2

Page 54: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

Assumed to contain Asbestos > 1%

Laboratory ABS Suspect Material Type * Percent Percent Percent

Sample # Sample # Material # Description Asbestos PLM TEM Point Count

71904215PLM_1 824‐01 ‐ A Den NAD

71904215PLM_2 824‐02 ‐ A Living Room NAD

71904215PLM_3 824‐03 ‐ A Master Bedroom NAD

71904215PLM_33 824‐01 ‐ B Den Chry 3%

71904215PLM_34 824‐02 ‐ B Living Room Chry 3%

71904215PLM_35 824‐03 ‐ B Master Bedroom Chry 3%

71904215PLM_4 824‐04 Dining Room Chry 3%

71904215PLM_5 824‐05 Bedroom 3 Chry 3%

71904215PLM_6 824‐06 Attic NAD

71904215PLM_7 824‐07 Attic NAD

71904215PLM_8 824‐08 Attic NAD

71904215PLM_9 824‐09 Master Bathroom NAD

71904215PLM_10 824‐10 Hall Bathroom NAD

71904215PLM_11 824‐11 Hall Bathroom NAD

71904215PLM_12 824‐12 Attic NAD

71904215PLM_13 824‐13 Attic NAD

71904430TBS_1 824‐14 NAD

71904215PLM_15 824‐15 NAD

71904215PLM_16 824‐16 NAD

71904430TBS_2 824‐17 Anth 0.015%

HM‐01 Sheetrock 

HM‐04 Ceramic Tile Thinset

Attic InsulationHM‐03

HM‐05 Duct Mastic

HM‐06 Exterior Window Glazing

Table #5Asbestos ‐ Bulk Sample Data Sheet

Project Name:

Project Address:

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via PLM

824 Burwell Lane

824 Burwell Ln., Columbia, SC 4‐Mar‐19

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via TEM

* Chry = Chrysotile Amos = Amosite Croc = Crocidolite Anth = Anthophylite NAD = No Asbestos Detected DNA = Did Not Analyze

Location

Joint CompoundHM‐02

*   NAD = No Asbestos Detected

 Amos = Amosite

DNA = Did Not Analyze

 Croc = Crocidilite

Chry = Chrysotile

Anth = Anthophylite

Page 55: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

Assumed to contain Asbestos > 1%

Laboratory ABS Suspect Material Type * Percent Percent Percent

Sample # Sample # Material # Description Asbestos PLM TEM Point Count

Table #5Asbestos ‐ Bulk Sample Data Sheet

Project Name:

Project Address:

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via PLM

824 Burwell Lane

824 Burwell Ln., Columbia, SC 4‐Mar‐19

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via TEM

* Chry = Chrysotile Amos = Amosite Croc = Crocidolite Anth = Anthophylite NAD = No Asbestos Detected DNA = Did Not Analyze

Location

71904215PLM_18 824‐18 NAD

71904215PLM_19 824‐19 NAD

71904430TBS_3 824‐20 NAD

71904215PLM_21 824‐21 NAD

71904215PLM_22 824‐22 NAD

71904430TBS_4 824‐23 NAD

71904215PLM_24 824‐24 Bedroom 1 NAD

71904215PLM_25 824‐25 Bedroom 2 NAD

71904430TBS_5 824‐26 Dining Room NAD

71904215PLM_27 824‐27 NAD

71904215PLM_28 824‐28 NAD

71904430TBS_6 824‐29 NAD

71904215PLM_30 824‐30 NAD

71904215PLM_31 824‐31 NAD

71904430TBS_7 824‐32 Chry 1.5%

Roof

Roof

HM‐07 Shingles

Felt PaperHM‐08

HM‐11 Exterior Caulk

HM‐09 Interior Felt Paper

HM‐10Vapor Barrier at Exterior 

Walls

*   NAD = No Asbestos Detected

 Amos = Amosite

DNA = Did Not Analyze

 Croc = Crocidilite

Chry = Chrysotile

Anth = Anthophylite

Page 56: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

824 Burwell Ln ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19005

LABORATORY RESULTS

Page 57: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

824 BURWELL LANEProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71904215_PLM

Date Reported: 2/19/2019

Date Received: 2/18/2019

Lab Order ID: 71904215

None Detected824-01 - A

SHEETROCK/JOINTCOMPOUND

drywall

White, BrownNon FibrousHeterogeneous

Crushed71904215PLM_1

Cellulose Other 12% 88%

3% Chrysotile

824-01 - BSHEETROCK/JOINTCOMPOUND

joint compound

WhiteNon FibrousHomogeneous

Crushed71904215PLM_33

Other 97%

None Detected824-02 - A

SHEETROCK/JOINTCOMPOUND

drywall

White, BrownNon FibrousHeterogeneous

Crushed71904215PLM_2

Cellulose Other 12% 88%

3% Chrysotile

824-02 - BSHEETROCK/JOINTCOMPOUND

joint compound

WhiteNon FibrousHomogeneous

Crushed71904215PLM_34

Other 97%

None Detected824-03 - A

SHEETROCK/JOINTCOMPOUND

drywall

White, BrownNon FibrousHeterogeneous

Crushed71904215PLM_3

Cellulose Other 12% 88%

3% Chrysotile

824-03 - BSHEETROCK/JOINTCOMPOUND

joint compound

WhiteNon FibrousHomogeneous

Crushed71904215PLM_35

Other 97%

3% Chrysotile

824-04JOINT COMPOUND

WhiteNon FibrousHomogeneous

Crushed71904215PLM_4

Other 97%

3% Chrysotile

824-05JOINT COMPOUND

WhiteNon FibrousHomogeneous

Crushed71904215PLM_5

Other 97%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 1 of 5

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Bart Huber (35)

P-F-002 r15 1/16/2021

Page 58: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

824 BURWELL LANEProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71904215_PLM

Date Reported: 2/19/2019

Date Received: 2/18/2019

Lab Order ID: 71904215

None Detected824-06

ATTIC INSULATIONGrayFibrousHeterogeneous

Teased71904215PLM_6

Fiber Glass Other 98% 2%

None Detected824-07

ATTIC INSULATIONGrayFibrousHeterogeneous

Teased71904215PLM_7

Fiber Glass Other 98% 2%

None Detected824-08

ATTIC INSULATIONGrayFibrousHeterogeneous

Teased71904215PLM_8

Fiber Glass Other 98% 2%

None Detected824-09

CERAMIC TILE THINSETGrayNon FibrousHeterogeneous

Crushed71904215PLM_9

Other 100%

None Detected824-10

CERAMIC TILE THINSETGrayNon FibrousHeterogeneous

Crushed71904215PLM_10

Other 100%

None Detected824-11

CERAMIC TILE THINSETGrayNon FibrousHeterogeneous

Crushed71904215PLM_11

Other 100%

None Detected824-12

DUCT MASTICGrayNon FibrousHeterogeneous

Dissolved71904215PLM_12

Other 100%

None Detected824-13

DUCT MASTIC

paint on paper

Blue, BrownFibrousHeterogeneous

Teased, Dissolved71904215PLM_13

Cellulose Other 95% 5%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 2 of 5

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Bart Huber (35)

P-F-002 r15 1/16/2021

Page 59: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

824 BURWELL LANEProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71904215_PLM

Date Reported: 2/19/2019

Date Received: 2/18/2019

Lab Order ID: 71904215

Not Analyzed824-14

DUCT MASTIC

TEM71904215PLM_14

None Detected824-15

EXTERIOR WINDOWGLAZING

GrayNon FibrousHeterogeneous

Crushed71904215PLM_15

Other 100%

None Detected824-16

EXTERIOR WINDOWGLAZING

GrayNon FibrousHeterogeneous

Crushed71904215PLM_16

Other 100%

Not Analyzed824-17

EXTERIOR WINDOWGLAZING

TEM71904215PLM_17

None Detected824-18

ROOF SHINGLESBlack, GrayNon FibrousHeterogeneous

Dissolved71904215PLM_18

Fiber Glass Other 15% 85%

None Detected824-19

ROOF SHINGLESBlack, GrayNon FibrousHeterogeneous

Dissolved71904215PLM_19

Fiber Glass Other 15% 85%

Not Analyzed824-20

ROOF SHINGLES

TEM71904215PLM_20

None Detected824-21

FELT PAPERBlackFibrousHeterogeneous

Teased, Dissolved71904215PLM_21

Cellulose Other 80% 20%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 3 of 5

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Bart Huber (35)

P-F-002 r15 1/16/2021

Page 60: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

824 BURWELL LANEProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71904215_PLM

Date Reported: 2/19/2019

Date Received: 2/18/2019

Lab Order ID: 71904215

None Detected824-22

FELT PAPERBlackFibrousHeterogeneous

Teased, Dissolved71904215PLM_22

Cellulose Other 80% 20%

Not Analyzed824-23

FELT PAPER

TEM71904215PLM_23

None Detected824-24

INTERIOR FELT PAPERBlackFibrousHeterogeneous

Teased, Dissolved71904215PLM_24

Cellulose Other 80% 20%

None Detected824-25

INTERIOR FELT PAPERBlackFibrousHeterogeneous

Teased, Dissolved71904215PLM_25

Cellulose Other 80% 20%

Not Analyzed824-26

INTERIOR FELT PAPER

TEM71904215PLM_26

None Detected824-27

VAPOR BARRIER ATEXTERIOR WALLS

BlackFibrousHeterogeneous

Teased, Dissolved71904215PLM_27

Cellulose Other 90% 10%

None Detected824-28

VAPOR BARRIER ATEXTERIOR WALLS

BlackFibrousHeterogeneous

Teased, Dissolved71904215PLM_28

Cellulose Other 90% 10%

Not Analyzed824-29

VAPOR BARRIER ATEXTERIOR WALLS

TEM71904215PLM_29

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 4 of 5

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Bart Huber (35)

P-F-002 r15 1/16/2021

Page 61: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011
Page 62: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011
lbrown
Text Box
Lane
Page 63: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

2/19/2019Project: 824 BURWELL LANE

Lab Order ID: 71904430

Lab Notes

Description

Lab Sample ID

Sample ID

Semi-QuantitativeChatfield SOP 1988-02 Rev. 1

Asbestos LCL-UCL

(Wt. %)

Bulk Asbestos Analysisby Transmission Electron Microscopy

Date Received:

2/20/2019Date Reported:

ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Customer:

Analysis ID: 71904430_TB

Attn: Jeff Rivers

Acid Sol.

Organic

(Wt. %)(Wt. %) (Wt. %)

None Detected-59%824-14

71904430TBS_1

DUCT MASTIC

70.%14%824-17

71904430TBS_2

EXTERIOR WINDOW GLAZING0.014% - 0.017%Anthophyllite0.015 %

None Detected-21%824-20

71904430TBS_3

ROOF SHINGLES

None Detected-94%824-23

71904430TBS_4

FELT PAPER

None Detected-95%824-26

71904430TBS_5

INTERIOR FELT PAPER

None Detected-97%824-29

71904430TBS_6

VAPOR BARRIER AT EXTERIOR WALLS

Russell Shelton (7)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Approved SignatoryPage 1 of 2tem_2.2.001

Analyst

Disclaimer: This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

T-F-010 r15 1/15/2018

Page 64: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

2/19/2019Project: 824 BURWELL LANE

Lab Order ID: 71904430

Lab Notes

Description

Lab Sample ID

Sample ID

Semi-QuantitativeChatfield SOP 1988-02 Rev. 1

Asbestos LCL-UCL

(Wt. %)

Bulk Asbestos Analysisby Transmission Electron Microscopy

Date Received:

2/20/2019Date Reported:

ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Customer:

Analysis ID: 71904430_TB

Attn: Jeff Rivers

Acid Sol.

Organic

(Wt. %)(Wt. %) (Wt. %)

-25%824-32

71904430TBS_7

EXTERIOR CAULK1.4% - 1.7%Chrysotile1.5 %

Russell Shelton (7)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Approved SignatoryPage 2 of 2tem_2.2.001

Analyst

Disclaimer: This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

T-F-010 r15 1/15/2018

Page 65: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

<< 824-01 824-02 824-03 824-04 824-05 824-06 824-07 824-08 824-09 824-10 824•11 824-12

· 824-13 824-14 824-15 824-16 824-17 824-18 824-19 824-20 824-21 824-22 824-23 824-24 824-25 824-28 824-27 824-28 824-29 824-30 824-31 824-32 >>

Relinquished By

i fl\llf't.ONMOOAL iJEfF,RNERS ''1416 CHAPIN RD.-CHAPIN, SC 8i:l3"'2('S!);'-ffil3'345~132!

(EnterP.O.#Here] ,, 2/15/2019 lllll0 "' ' - ~

'.~"'f~iltill:,,J; ;;,;' ::: ,trr.f%1~~t~5::llti£: ·

[Enter data of your choosing here) SHEETROCK/JOINT COMPOUND [Enter data of your choosing here) SHEETROCK/JOINT COMPOUND [Enter data of your choosing here] SHEETROCK/JOINT COMPOUND [Enter data of your choosing here] JOINT COMPOUND {Enter data of your choosing here) JOINT COMPOUND [Enter data of your choosing here) ATTIC INSULATION [Enter data of your choosing here] ATTIC INSULATION [Enter data of your choosing here) ATTIC INSULATION [Enter data of your choosing here] CERAMIC TILE THINS ET [Enter data of your choosing here] CERAMIC TILE THINSET [Enter data of your choosing here] CERAMIC TILE THINSET

DUCT MASTIC DUCT MASTIC DUCT MASTIC EXTERIOR WINDOW GLAZING EXTERIOR WINDOW GLAZING EXTERIOR WINDOW GLAZING ROOF SHINGLES ROOF SHINGLES ROOF SHINGLES FELT PAPER FELT PAPER FELT PAPER INTERIOR FELT PAPER INTERIOR FELT PAPER INTERIOR FELT PAPER VAPOR BARRIER AT EXTERIOR WALLS VAPOR BARRIER AT EXTERIOR WALLS VAPOR BARRIER AT EXTERIOR WALLS EXTERIOR CAULK EXTERIOR CAULK EXTERIOR CAULK

[Enter data of your choosing here) [Enter data of your choosing hereJ [Enter d.,ta of your choosing here) [Enter data of your choosing here] [Enter data of your choosing here) [Enter data of your choosing here) (Enter d.ata of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here) (Enter data of your choosing here] [Enter data of your choosing here]

TEM NOB IF NEGATIVE

TEM NOB IF NEGATIVE

TEM NOB IF NEGATIVE

TEM NOB IF NEGATIVE

TEM NOB IF NEGATIVE

TEM NOB IF NEGATIVE

TEM NOB IF NEGATIVE

11cro#30

Accepted

Retected 0

~ ~-r): 12 I D '. :?i)fi-f\\

lbrown
Text Box
Lane
Page 66: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Prepared

Prepared

Inspectio

Report P

Report R

d for:

d by:

on Performed

repared by:

Reviewed by

83

City of CoAttn: Dav1136 WasColumbia

ABS Envi1416 ChapChapin, SABS Job #

d by:

:

Mar

Asbes

36 Burwell

olumbiavid Hatchershington Stra, SC 29201

ironmental,pin Road

SC 29036# 7800.1900

Jeff R

Jeff R

Lee C

ch 12, 201

stos SurvFor

Lane, Colu

reet

, Inc.

06

Rivers

Rivers

Capell

19

vey

mbia, SC

P

P

SCDMP –

SCDMP –

SCDMP –

Phone: (803

Phone: (803

DHEC # – 00166

DHEC # – 00166

DHEC # – 00072

3) 545-3444

3) 345-3833

Lic Exp D8/1/19

Lic Exp D8/1/19

Lic Exp D8/8/19

Date

Date

Date

Page 67: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

836 Burwell Ln ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19006

TABLE OF CONTENTS

1.0 EXECUTIVE SUMMARY

2.0 APPENDIX

A. Drawing

B. Site Map

C. Tables

D. Laboratory Results

Page 68: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

836 Burwell Ln ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19006

1.0 EXECUTIVE SUMMARY

ABS Environmental, Inc. (ABS) was retained by the City of Columbia to perform an asbestos survey at 836 Burwell Lane in Columbia, SC. The primary objective of this survey was to identify, sample and physically assess suspect asbestos-containing building materials (ACBM) associated with the vacant residence. The subject structure is a single-family residence built over a crawlspace. The roof is built in a gabled configuration and is covered with architectural shingles. The exterior is clad primarily with brick veneer. Interior finishes include: Ceilings/Walls: Wood-frame walls and ceilings. Floors: Combination of ceramic tile and wood floors. Ceramic tile is on top of 9” vinyl tile in the kitchen. The building measures approximately 2,692 ft2. Ten (10) suspect materials were identified, sampled and analyzed for the presence of asbestos. Samples were delivered by overnight courier service to SAI, Inc. for analysis using Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM) to confirm negative PLM results for non-friable organically bound materials. As indicated by laboratory analysis, those materials containing asbestos > 1 % include approximately:

280 ft2 of 9” floor tile and mastic located under ceramic tile in the Kitchen.

22 windows with exterior window glazing.

12 LF of chimney flashing. Limitations This survey and report have been executed at the request of Mr. David Hatcher and City of Columbia and are intended solely for their use. All work related to this project has been conducted in keeping with accepted standards of environmental consulting as practiced in the State of South Carolina. No unnecessary destructive measures were undertaken during this survey. Additional suspect and/or asbestos containing materials may be present. If at any time during the course of renovation or demolition a suspect material is observed that is not identified in this report, stop work immediately until the material can be sampled and analyzed for the presence of asbestos. ABS has relied, in part, on information derived from secondary sources, and except as set forth herein, ABS has made no independent investigation as to the accuracy or completeness of the information derived from such secondary sources. No warranty is expressed or implied.

Page 69: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

836 Burwell Ln ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19006

DRAWING

Page 70: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011
Page 71: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

836 Burwell Ln ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19006

SITE MAP

Page 72: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

836 Burwell Ln ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19006

TABLES

Page 73: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

*  Assumed to Contain Asbestos > 1%

Chimney Flashing Miscellaneous 12 LF

Exterior Window Glazing Miscellaneous 22 windows

Table #1Asbestos Containing Building Material (ACBM)

Project Name: 836 Burwell Lane

Project Address: 836 Burwell Ln., Columbia, SC 12‐Mar‐19

Observed ACBMMaterial EPA AHERA Category Quantity

9" Floor Tile/Mastic Miscellaneous 280 ft2

Page 74: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

*  Assumed to Contain Asbestos > 1%

Chimney Flashing 12 LF

Exterior Window Glazing 22 windows

Table #2Non‐Friable ACBM

Project Name: 836 Burwell Lane

Project Address: 836 Burwell Ln., Columbia, SC 12‐Mar‐19

Non‐Friable ACBM

Material Quantity

9" Floor Tile/Mastic 280 ft2

Page 75: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

F = Friable NF= Non Friable

G = Good (Very localized damage)

S = Surfacing Material (Spray‐applied or trowel applied)

Suspect Material Category # Present Disturbance P or N P or N P or N Hazard

Material # Description (S, T, M) Samples Condition Potential PLM TEM Point Count Ranking

HM‐01 Attic Insulation T 3 2,692 ft2 F/G PD N NA

HM‐02 Ceramic Tile M 3 340 ft2 NF/G PD N NA

HM‐03 Ceramic Tile Thinset M 3 340 ft2 NF/G LPD N NA

HM‐04 9" Floor Tile M 3 280 ft2 NF/G PD P 2

HM‐05 Mastic below HM‐04 M 3 280 ft2 NF/G LPD P 1

HM‐06Exterior Window 

GlazingM 3 22 windows NF/G PD P 2

HM‐07 Roof Shingles M 3 4,038 ft2 NF/G PD N N NA

HM‐08 Felt Paper M 3 4,038 ft2 NF/G LPD N N NA

HM‐09 Exterior Caulk M 3 5 doors NF/G PD N N NA

HM‐10 Chimney Flashing M 3 12 LF NF/G PD N P 2

836 Burwell Lane

Table #3Asbestos ‐ Suspect Material Data Sheet

Project Name:

PD = Potential for Damage (Any One Mechanism of Moderate Concern)

LPD = Low Potential for Disturbance (All Three Mechanisms of Low Concern) 

PTP = Previously tested Positive

PTN = Previously tested Negative

Quantity

P = Positive via PLM

P = Positive via TEM

N = Negative: does not meet definition of ACM

A = Assumed to be ACM; no samples collected

Present Condition

SD = Significantly Damaged (Damage equal to or greater than 10 % distributed/ 25 % localized)

D = Damaged (Damage less than 10 distributed and less than 25 % localized)

M = Miscellaneous Materials (Refer to as "Other" materials by OSHA)

T = Thermal System Insulation (Inhibits heat transfer or prohibits condensation)

of High Concern or More Than One of Moderate Concern)

PSD = Potential for Significant Damage (One Mechanism

Potential for Future Disturbance by Contact, Vibration or Air Erosion Mechanisms

EPA AHERA Asbestos Category

Hazard Ranking  = 7 thru 1; (7 being the worst i.e. significantly damaged material)

Asbestos Finding;                    Asbestos Containing Material (ACM) contains > 1% asbestos by definition

Project Address: 12‐Mar‐19836 Burwell Ln., Columbia, SC

Page 76: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

Assumed to contain Asbestos > 1%

Laboratory ABS Suspect Material Type * Percent Percent Percent

Sample # Sample # Material # Description Asbestos PLM TEM Point Count

71904216PLM_1 836‐01 Dining Room NAD

71904216PLM_2 836‐02 Living Room NAD

71904216PLM_3 836‐03 Den NAD

71904216PLM_4 836‐04 ‐ A Kitchen NAD

71904216PLM_5 836‐05 ‐ A Kitchen NAD

71904216PLM_6 836‐06 ‐ A Kitchen NAD

71904216PLM_20 836‐04 ‐ B Kitchen NAD

71904216PLM_21 836‐05 ‐ B Kitchen NAD

71904216PLM_22 836‐06 ‐ B Kitchen NAD

71904216PLM_7 836‐07 ‐ A Kitchen Chry 5%

71904216PLM_8 836‐08 ‐ A Kitchen Chry 5%

71904216PLM_9 836‐09 ‐ A Kitchen Chry 5%

71904216PLM_23 836‐07 ‐ B Kitchen Chry 4%

71904216PLM_24 836‐08 ‐ B Kitchen Chry 4%

71904216PLM_25 836‐09 ‐ B Kitchen Chry 4%

71904216PLM_10 836‐10 Dining Room Chry 2%

71904216PLM_11 836‐11 Living Room Chry 2%

71904216PLM_12 836‐12 Bedroom 1 Chry 2%

HM‐01 Attic Insulation

HM‐04 9" Floor Tile

Ceramic Tile Thinset

* Chry = Chrysotile Amos = Amosite Croc = Crocidolite Anth = Anthophylite NAD = No Asbestos Detected DNA = Did Not Analyze

Location

Ceramic TileHM‐02

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via PLM

836 Burwell Lane

836 Burwell Ln., Columbia, SC 12‐Mar‐19

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via TEM

Table #4Asbestos ‐ Bulk Sample Data Sheet

Project Name:

Project Address:

HM‐03

HM‐05 Mastic below HM‐04

HM‐06 Exterior Window Glazing

*   NAD = No Asbestos Detected

 Amos = Amosite

DNA = Did Not Analyze

 Croc = Crocidilite

Chry = Chrysotile

Anth = Anthophylite

Page 77: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

Assumed to contain Asbestos > 1%

Laboratory ABS Suspect Material Type * Percent Percent Percent

Sample # Sample # Material # Description Asbestos PLM TEM Point Count

* Chry = Chrysotile Amos = Amosite Croc = Crocidolite Anth = Anthophylite NAD = No Asbestos Detected DNA = Did Not Analyze

Location

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via PLM

836 Burwell Lane

836 Burwell Ln., Columbia, SC 12‐Mar‐19

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via TEM

Table #4Asbestos ‐ Bulk Sample Data Sheet

Project Name:

Project Address:

71904216PLM_13 836‐13 NAD

71904216PLM_14 836‐14 NAD

71904387TBS_1 836‐15 NAD

71904216PLM_16 836‐16 NAD

71904216PLM_17 836‐17 NAD

71904387TBS_2 836‐18 NAD

71904410PLM_1 836‐20 Entry NAD

71904410PLM_2 836‐21 Storage NAD

71904536TBS_1 836‐22 NAD

71906206PLM_1 836‐23 NAD

71906206PLM_2 836‐24 NAD

71906290TBS_1 836‐25 Anth 1.5%

Roof

Roof

HM‐07 Shingles

HM‐10 Chimney Flashing 

Felt PaperHM‐08

HM‐09 Exterior Caulk

*   NAD = No Asbestos Detected

 Amos = Amosite

DNA = Did Not Analyze

 Croc = Crocidilite

Chry = Chrysotile

Anth = Anthophylite

Page 78: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

836 Burwell Ln ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19006

LABORATORY RESULTS

Page 79: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

836 BURWELLProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71904216_PLM

Date Reported: 2/19/2019

Date Received: 2/18/2019

Lab Order ID: 71904216

None Detected836-01

ATTIC INSULATIONGrayFibrousHomogeneous

Teased, Dissolved71904216PLM_1

Mineral Wool Other 98% 2%

None Detected836-02

ATTIC INSULATIONGrayFibrousHomogeneous

Teased, Dissolved71904216PLM_2

Mineral Wool Other 98% 2%

None Detected836-03

ATTIC INSULATIONGrayFibrousHomogeneous

Teased, Dissolved71904216PLM_3

Mineral Wool Other 98% 2%

None Detected836-04 - A

CERAMIC TILE THINSET

ceramic tile

WhiteNon FibrousHomogeneous

Dissolved71904216PLM_4

Other 100%

None Detected836-04 - B

CERAMIC TILE THINSET

thinset

GrayNon FibrousHomogeneous

Dissolved71904216PLM_20

Other 100%

None Detected836-05 - A

CERAMIC TILE THINSET

ceramic tile

WhiteNon FibrousHomogeneous

Dissolved71904216PLM_5

Other 100%

None Detected836-05 - B

CERAMIC TILE THINSET

thinset

GrayNon FibrousHomogeneous

Dissolved71904216PLM_21

Other 100%

None Detected836-06 - A

CERAMIC TILE THINSET

ceramic tile

WhiteNon FibrousHomogeneous

Dissolved71904216PLM_6

Other 100%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 1 of 4

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Megan Javonovich (4)Philip Szabo (21)

P-F-002 r15 1/16/2021

Page 80: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

836 BURWELLProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71904216_PLM

Date Reported: 2/19/2019

Date Received: 2/18/2019

Lab Order ID: 71904216

None Detected836-06 - B

CERAMIC TILE THINSET

thinset

GrayNon FibrousHomogeneous

Dissolved71904216PLM_22

Other 100%

5% Chrysotile

836-07 - A9" FLOOR TILE ANDMASTIC

tile

GreenNon FibrousHomogeneous

Dissolved71904216PLM_7

Other 95%

4% Chrysotile

836-07 - B9" FLOOR TILE ANDMASTIC

mastic

BlackNon FibrousHomogeneous

Dissolved71904216PLM_23

Other 96%

5% Chrysotile

836-08 - A9" FLOOR TILE ANDMASTIC

tile

GreenNon FibrousHomogeneous

Dissolved71904216PLM_8

Other 95%

4% Chrysotile

836-08 - B9" FLOOR TILE ANDMASTIC

mastic

BlackNon FibrousHomogeneous

Dissolved71904216PLM_24

Other 96%

5% Chrysotile

836-09 - A9" FLOOR TILE ANDMASTIC

tile

GreenNon FibrousHomogeneous

Dissolved71904216PLM_9

Other 95%

4% Chrysotile

836-09 - B9" FLOOR TILE ANDMASTIC

mastic

BlackNon FibrousHomogeneous

Dissolved71904216PLM_25

Other 96%

2% Chrysotile

836-10EXTERIOR WINDOWGLAZING

TanNon FibrousHomogeneous

Ashed, Dissolved71904216PLM_10

Other 98%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 2 of 4

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Megan Javonovich (4)Philip Szabo (21)

P-F-002 r15 1/16/2021

Page 81: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

836 BURWELLProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71904216_PLM

Date Reported: 2/19/2019

Date Received: 2/18/2019

Lab Order ID: 71904216

2% Chrysotile

836-11EXTERIOR WINDOWGLAZING

TanNon FibrousHomogeneous

Ashed, Dissolved71904216PLM_11

Other 98%

2% Chrysotile

836-12EXTERIOR WINDOWGLAZING

TanNon FibrousHomogeneous

Ashed, Dissolved71904216PLM_12

Other 98%

None Detected836-13

ROOF SHINGLESBlackNon FibrousHomogeneous

Dissolved71904216PLM_13

Fiber Glass Other 10% 90%

None Detected836-14

ROOF SHINGLESBlackNon FibrousHomogeneous

Dissolved71904216PLM_14

Fiber Glass Other 10% 90%

Not Analyzed836-15

ROOF SHINGLES

71904216PLM_15

None Detected836-16

FELT PAPERBlackFibrousHomogeneous

Dissolved71904216PLM_16

Cellulose Other 70% 30%

None Detected836-17

FELT PAPERBlackFibrousHomogeneous

Dissolved71904216PLM_17

Cellulose Other 70% 30%

Not Analyzed836-18

FELT PAPER

71904216PLM_18

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 3 of 4

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Megan Javonovich (4)Philip Szabo (21)

P-F-002 r15 1/16/2021

Page 82: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

836 BURWELLProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71904216_PLM

Date Reported: 2/19/2019

Date Received: 2/18/2019

Lab Order ID: 71904216

Not Submitted836-19

71904216PLM_19

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 4 of 4

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Megan Javonovich (4)Philip Szabo (21)

P-F-002 r15 1/16/2021

Page 83: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

P!OJtct:

<< 836-01 836-02 836-03 836-04 836-05 836-06 836-07 836-08 836-09 836-10 836-11 836-12 836-13 836-14 836-15 836-16 836-17 836-18 836-19 >>

Relinquished By

ABS ENVIRONMENT AL JEFF RIVERS 1416 CHAPIN RD.-CHAPIN, SC 803-260-2883 803-345-2823 [email protected]

836 BURWELL

[Enter Client Notes Here]

[Enter P.O. # Here]

EPA PLM 600 24 HR TAT

O,ati1

2/15/2019 0:00

Semple Description

[Enter data of your choosing here] ATTIC INSULATION [Enter data of your choosing here] ATTIC INSULATION [Enter data of your choosing here] ATTIC INSULATION [Enter data of your choosing here] CERAMIC TILE TH INSET [Enter data of your choosing here] CERAMIC TILE TH INSET [Enter data of your choosing here] CERAMIC TILE TH INSET [Enter data of your choosing here] 9" FLOOR TILE AND MASTIC [Enter data of your choosing here] 9" FLOOR TILE AND MASTIC [Enter data of your choosing here] 9" FLOOR TILE AND MASTIC [Enter data of your choosing _here] EXTERIOR WINDOW GLAZING [Enter data of your choosing here] EXTERIOR WINDOW GLAZING

EXTERIOR WINDOW GLAZING ROOF SHINGLES ROOF SHINGLES ROOF SHINGLES FELT PAPER FELT PAPER FELT PAPER

Sf!•ntl(!c Ana/ytlcal

l~ tltU:,f _

~-'' 4t;,'}4 Du1?,das Drl'vf! -~ __ :_ .. ·!! Greensboro, N'r;: 27407'1' Phone: 336.2f12.3888 (liFaic:11336.292.331."3

Email: lab@sallab.~m

[Enter data of your choosing here] [Enter data of your choosing here]

• [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] TEM NOB IF NEGATIVE [Enter data of your choosing here] [Enter data of your choosing here] TEM NOB IF NEGATIVE

TEM NOB IF NEGATIVE

TEM NOB IF NEGATIVE

-'1 I q 04 21 lf;

Accepted

Rejected 0

t0.1 g Received By

{0;30fn'VL

Page 84: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

2/19/2019Project: 836 BURWELL

Lab Order ID: 71904387

Lab Notes

Description

Lab Sample ID

Sample ID

Semi-QuantitativeChatfield SOP 1988-02 Rev. 1

Asbestos LCL-UCL

(Wt. %)

Bulk Asbestos Analysisby Transmission Electron Microscopy

Date Received:

2/20/2019Date Reported:

ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Customer:

Analysis ID: 71904387_TB

Attn: Jeff Rivers

Acid Sol.

Organic

(Wt. %)(Wt. %) (Wt. %)

None Detected-23%836-15

71904387TBS_1

Roof shingles

None Detected-96%836-18

71904387TBS_2

Felt paper

Russell Shelton (2)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Approved SignatoryPage 1 of 1tem_2.2.001

Analyst

Disclaimer: This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

T-F-010 r15 1/15/2018

Page 85: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

<< 836-01 836-02

· 836-03 836-04 836-05 836-06 836-07 836-08 836-09 836-10 836-11 836-12 836-13

· 836-14 836-15 836-16 836-17 836-18 836-19 >>

Relinquished By

1,0~7

[E:ntef P.O. # Here] 211512019-l'.l;QO

·· ?~ ::::"triI,\iiit~t(,,r;: , ;,·.,.,,,,,:;:i~,"-~L>. ""- ·; .:. qr )I

(Enter data of your choos,ing here) ATTIC INSULATION (Enter data of your choosing here] ATTIC INSULATION (Enter data of your choosing here) ATTIC INSULATION [Enter data of your choosing here] CERAMIC TILE THINSET [Enter data of your choosing here} CERAMIC TILE THINSET [Enter data of your choosing here) CERAMIC TILE THINSET [Enter data of your choosing here] 9" FLOOR TILE AND MASTIC [Enter data of your choosing here] 9" FLOOR TILE AND MASTIC [Enter data of your choosing here] 9" FLOOR TILE AND MASTIC [Enter data of your choQsing,here] EXTERIOR WINDOW GLAZING [Enter data of your choosing here] EXTERIOR WINDOW GLAZING

EXTERIOR WINDOW GLAZING ROOF SHINGLES ROOF SHINGLES ROOF SHINGLES FELT PAPER FELT PAPER FELT PAPER

[Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here} TEM NOB IF NEGATIVE [Enter data of your choosing here} [Enter data of your choosing here) TEM NOB IF NEGATIVE

TEM NOB IF NEGATIVE

TEM NOB IF NEGATIVE

Accepted

Rejected 0

i ~ .0.1 e i0;730~

Page 86: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

836 BurwellProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71904410_PLM

Date Reported: 2/19/2019

Date Received: 2/19/2019

Lab Order ID: 71904410

None Detected836-20

Exterior CaulkWhiteNon FibrousHomogeneous

Ashed71904410PLM_1

Other 100%

None Detected836-21

Exterior CaulkWhiteNon FibrousHomogeneous

Ashed71904410PLM_2

Other 100%

Not Analyzed836-22

Exterior Caulk

TEM71904410PLM_3

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 1 of 1

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Byron Stroble (3)

P-F-002 r15 1/16/2021

Page 87: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Client: Contact: Address: Phone: Fax: Email:

Project:

Client Notes:

ABS ENVIRONMENTAL JEFF RIVERS 1416 CHAPIN RD.-CHAPIN , SC 803-260-2883 803-345-2823 [email protected]

836 Burwell

TEM NOB 72 HR TAT

P.O.#. l[Enter P.O.# Here] Date Submitted: · 2/18/2019 0:00

Analysis: IEPA PLM 600 TurnAroundTime: 24 HR TAT

!Sample Number Data 1

*Instructions: Use Column "B" for your contact info

To See an Example Click the bottom Example Tab.

Enter samples between "<<" and ">>" Begin Samples with a "<< "above the first sample

and end with a ">>" below the last sample. Only Enter your data on the first sheet "Sheet1"

Note: Data 1 and Data 2 are optional fields that do not show up on the official report, however they will be included in the electronic data returned to you

to facilltateyour reintegration of the report data.

Sample Description << 836-20 836-21 836-22 >>

[Enter data of your choosing here) Exterior Caulk [Enter data of your choosing here] Exterior Caulk [Enter data of your choosing here) . Exterior Caulk

Relinquished By

7\C)CWL{IO

Scientific Analytical Institute

4604 Dundas Drive Greensboro, NC 27407 Phone: 336.292.3888

Fax: 336.292.331.3 Email: [email protected]

Data 2

[Enter data of your choosing here] [Enter data of your choosing here) TEM NOB If Negative

Accepted~

Rejected D

Received By

aro~l i 1filb. a -\ C) I D-2DOi'Y)

Page 88: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

2/20/2019Project: 836 Burwell

Lab Order ID: 71904536

Lab Notes

Description

Lab Sample ID

Sample ID

Semi-QuantitativeChatfield SOP 1988-02 Rev. 1

Asbestos LCL-UCL

(Wt. %)

Bulk Asbestos Analysisby Transmission Electron Microscopy

Date Received:

2/25/2019Date Reported:

ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Customer:

Analysis ID: 71904536_TB

Attn: Jeff Rivers

Acid Sol.

Organic

(Wt. %)(Wt. %) (Wt. %)

None Detected-26%836-22

71904536TBS_1

Exterior Caulk

Russell Shelton (1)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Approved SignatoryPage 1 of 1tem_2.2.001

Analyst

Disclaimer: This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

T-F-010 r15 1/15/2018

Page 89: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

<< 836,-20 836:2'1 836-22 >>

Relinquished By

.

ABS ENVIRONMENTAL JEFF RIVERS : 1416 CHAPIN RD.-CHAPIN, SC 803-260-2883 803-345.:2823 [email protected]

: ~ .. ~(

[Enter data;of your cpoosing her~] Exteripr'Gaul~ [Enter data'ofyour choosing here]'' Extei'i9r Cauik [Enter data o(your choosing here] .. Exterior Caulk

~A

71qoy1330

[Enter data of your choosing here] · [Enter data of your choosing here] TEM NOB If Negative

Accepted [c{ Rejected []

i ,/

Received By

C)!Q~l)llili.t~ B -\Q ID•?DOtY,

Page 90: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

836 BurwellProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71906206_PLM

Date Reported: 3/7/2019

Date Received: 3/7/2019

Lab Order ID: 71906206

None Detected836-23

Chimney FlashingBlackNon FibrousHomogeneous

Dissolved71906206PLM_1

Other Other 2% 98%

None Detected836-24

Chimney FlashingBlackNon FibrousHomogeneous

Dissolved71906206PLM_2

Other Other 2% 98%

Not Analyzed824-25 Chimney Flashing

bag labeled 836-25-TEM71906206PLM_3

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 1 of 1

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Philip Szabo (3)

P-F-002 r15 1/16/2021

Page 91: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

~nalts!C~ . ffiLJ r,nArou nli;Jllm.e:

836-23 836-24 824-35 >>

Relinquished By

ABS ENVIRONMENTAL JEFF RIVERS 1416 CHAPIN RD.-CHAPIN, SC 803-260-2883 803-345-2823 [email protected]

72 HR TAT for TEM NOB

[Enter P.O. # Here] . ·- 3/6/2019 0:00

rpat1,1 1

*Instructions: ,. Use Column "B" for:your contacf' info

, * TomSee an Exampte·c/ick the

¢ ?<' , , , iH

bottom Example Tab:

:Srtrof1@• IDss~-ripti~'l-

[Enter data of your choosing here] Chimney Flashing [Enter data of your choosing here] Chimney Flashing [Enter data of your choosing here] Chimney Flashing

1101 D l{ZJ) ep

,, 4:6Q(I Duqda_s Drive ,, :G1;J~e,p.s~or9,,/J;C ]lt0'{,1

Pftone: 336.292.,3/!BB #al: 336?~92.33i:_'3

Email: .. la'[email protected]

[Enter data of your choosing here) [Enter data of your choosing here] TEM NOB If Negative

Accepted

Rejected

d D

f ~ -:t.fr·1 Dy: s D11!1

Page 92: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

3/8/2019Project: 836 Burwell

Lab Order ID: 71906290

Lab Notes

Description

Lab Sample ID

Sample ID

Semi-QuantitativeChatfield SOP 1988-02 Rev. 1

Asbestos LCL-UCL

(Wt. %)

Bulk Asbestos Analysisby Transmission Electron Microscopy

Date Received:

3/13/2019Date Reported:

ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Customer:

Analysis ID: 71906290_TB

Attn: Jeff Rivers

Acid Sol.

Organic

(Wt. %)(Wt. %) (Wt. %)

-27%824-35

71906290TBS_1

Chimney flashing1.3% - 1.6%Anthophyllite1.5 %

Russell Shelton (1)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Approved SignatoryPage 1 of 1tem_2.2.001

Analyst

Disclaimer: This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

T-F-010 r15 1/15/2018

Page 93: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Client; Contact: Address: Phone: Fax: Email:

roject:

Client .Notes:

ABS ENVIRONMENTAL JEFF RIVERS 1416 CHAPIN RD.-CHAPIN, SC 803-260-2883 803-345-2823 [email protected]

836 Burwell

-• 72 HR TATforTEM NOB

P.O.#. J(Enter P.O.# Here] Datt(Sub~: ~' 3/6/2019 0:00

Analysis! . . ·1EPA PLM 600 tumArO.updTlme-: ., 24 HR TAT

*Instructions: r, ,.,:

Use Column "B" for your Q.QQ.(P,gjinfo . ·.···:,. 1.,~<::ii~~-~

To See an Exa,mple Click tf!(J;] bottom Example Tab. ..,.

Enter samples between •<<" and· ">>" Begin ,amp/es with a "<< ·above the first sample

-•~tft111{J with a.">>" below the last ~mp1,, . ·only'II!Jfer yautdaf.a on the first sheet nsheet1b·.

•,·tet Data 1 and Data 2 are optional •

1ha.tdo not show up on the offfci~I . ,,. •v,w,f, hlWiever they will be inc/ud&lf'' ·.: , · ''JJIJ!l;J eleotn)nlc data returned to you

k!:~_Your rein~tlon of the report data.

4l01 D Lf2P({2-. -. 71qDlJBqD

Sdentifie Analytical Institute

/

4604 Pt!mdas Drive Greensboro, NC 27407 Phone: 336.292.3888

Fax: 336.292.33J3 Email: [email protected]

IP#[email protected]:H~l.:.' ::Bik•l:E»Jifl :!i£}r. ¾,~;-:finiii@ll!@i!on ~~ ,;• .&:·s · ·t-·· ····~£..-. QataJ {~a ;:, ~~, ~ : I"'!

"" • .

<< 836-23 836-24 824-35 >>

Relinquished By

[Enter data of your choosing here] .. Chimney Flashing [Enter data of your choosing·here] Chimney Flashing [Enter data of your choosing here] Chimney Flashing

[Enter data of your choosing here] [Enter data of your choosing here] TEM NOB_ If Negative

Accepted

Rejected

~ D

f ~ ,s.:-rvel Oy: 2 01/fr/

Page 94: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Prepared

Prepared

Inspectio

Report P

Report R

d for:

d by:

on Performed

repared by:

Reviewed by

1226

City of CoAttn: Dav1136 WasColumbia

ABS Envi1416 ChapChapin, SABS Job #

d by:

:

Mar

Asbes

6 Glenhaven

olumbiavid Hatchershington Stra, SC 29201

ironmental,pin Road

SC 29036# 7800.1901

Jeff R

Jeff R

Lee C

ch 15, 201

stos SurvFor

n Drive, Co

reet

, Inc.

13

Rivers

Rivers

Capell

19

vey

olumbia, SC

P

P

SCDMP –

SCDMP –

SCDMP –

C

Phone: (803

Phone: (803

DHEC # – 00166

DHEC # – 00166

DHEC # – 00072

3) 545-3444

3) 345-3833

Lic Exp D8/1/19

Lic Exp D8/1/19

Lic Exp D8/8/19

Date

Date

Date

Page 95: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

1226 Glenhaven Dr ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19013

TABLE OF CONTENTS

1.0 EXECUTIVE SUMMARY

2.0 APPENDIX

A. Drawing

B. Site Map

C. Tables

D. Laboratory Results

Page 96: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

1226 Glenhaven Dr ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19013

1.0 EXECUTIVE SUMMARY

ABS Environmental, Inc. (ABS) was retained by the City of Columbia to perform an asbestos survey at 1226 Glenhaven Drive in Columbia, SC. The primary objective of this survey was to identify, sample and physically assess suspect asbestos-containing building materials (ACBM) associated with the vacant residence. The subject structure is a single-family residence built over a crawlspace. The roof is built in an intersecting gabled configuration and is covered with 3-tab composition shingles. The exterior is clad primarily with brick veneer. Interior finishes include: Ceilings/Walls: Combination of sheetrock and plaster Floors: Combination of ceramic tile and wood floors The vacant residence measures approximately 2,695 ft2. Twenty (20) suspect materials were identified, sampled and analyzed for the presence of asbestos. Samples were delivered by overnight courier service to SAI, Inc. for analysis using Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM) to confirm negative PLM results for non-friable organically bound materials. As indicated by laboratory analysis, those materials containing asbestos > 1 % include approximately:

805 ft2 of joint compound and/or spray-applied texture on the ceilings, primarily in the upper level. A few of the electrical boxes on the main level ceilings have overspray.

864 ft2 of joint compound on walls primarily in the upper level.

134 LF of duct tape in the crawlspace.

126 ft2 ceramic tile thinset in the Laundry Room.

10 LF of chimney flashing. Limitations This survey and report have been executed at the request of Mr. David Hatcher and City of Columbia and are intended solely for their use. All work related to this project has been conducted in keeping with accepted standards of environmental consulting as practiced in the State of South Carolina. No unnecessary destructive measures were undertaken during this survey. Additional suspect and/or asbestos containing materials may be present. If at any time during the course of renovation or demolition a suspect material is observed that is not identified in this report, stop work immediately until the material can be sampled and analyzed for the presence of asbestos. ABS has relied, in part, on information derived from secondary sources, and except as set forth herein, ABS has made no independent investigation as to the accuracy or completeness of the information derived from such secondary sources. No warranty is expressed or implied.

Page 97: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

1226 Glenhaven Dr ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19013

DRAWING

Page 98: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011
Page 99: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

1226 Glenhaven Dr ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19013

SITE MAP

Page 100: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

1226 Glenhaven Dr ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19013

TABLES

Page 101: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

*  Assumed to Contain Asbestos > 1%

Observed ACBMMaterial EPA AHERA Category Quantity

Ceiling Texture Surfacing 805 ft2

Table #1Asbestos Containing Building Material (ACBM)

Project Name: 1226 Glenhaven Drive

Project Address: 1226 Glenhaven Dr., Columbia, SC 15‐Mar‐19

Chimney Flashing Miscellaneous 10 LF

Joint Compound: Ceilings Surfacing 805 ft2

Joint Compound: Walls Surfacing 864 ft2

Ceramic Tile Thinset (Lower Level) Miscellaneous 126 ft2

Duct Tape Miscellaneous 134 LF

Page 102: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

*  Assumed to Contain Asbestos > 1%

Friable ACBM

Material Quantity

Ceiling Texture 805 ft2

Table #2Friable ACBM

Project Name: 1226 Glenhaven Drive

Project Address: 1226 Glenhaven Dr., Columbia, SC 15‐Mar‐19

Ceramic Tile Thinset (Lower Level) 126 ft2Joint Compound: Walls 864 ft

2

Joint Compound: Ceilings 805 ft2

Page 103: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

*  Assumed to Contain Asbestos > 1%

Non‐Friable ACBM

Material Quantity

Table #3Non‐Friable ACBM

Project Name: 1226 Glenhaven Drive

Project Address: 1226 Glenhaven Dr., Columbia, SC 15‐Mar‐19

Duct Tape

Chimney Flashing

134 LF

10 LF

Page 104: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

F = Friable NF= Non Friable

G = Good (Very localized damage)

S = Surfacing Material (Spray‐applied or trowel applied)

Suspect Material Category # Present Disturbance P or N P or N P or N Hazard

Material # Description (S, T, M) Samples Condition Potential PLM TEM Point Count Ranking

HM‐01 Ceiling Texture S 3 805 ft2 F/G PD P 2

HM‐02 Sheetrock M 3 1,669 ft2 F/G PD N NA

Joint Comp: Ceilings 805 ft2 F/G PD

Joint Comp: Walls 864 ft2 F/G PD

HM‐04 Plaster: Finish S 5 1,620 ft2 F/G PD N NA

HM‐05 Plaster: Base S 5 1,620 ft2 F/G PD N NA

HM‐06Silver Paint on Wood 

TrussesM 3 667 ft

2 NF/G PD N N NA

HM‐07 Duct Tape M 3 134 LF NF/G PD P 2

HM‐08 Interior Felt Paper M 3 536 ft2 NF/G PD N N NA

HM‐09Ceramic Tile Thinset 

(Laundry)M 3 126 ft

2 F/G PD P 2

Asbestos Finding;                    Asbestos Containing Material (ACM) contains > 1% asbestos by definition

Project Address: 15‐Mar‐191226 Glenhaven Dr., Columbia, SC

Quantity

P = Positive via PLM

P = Positive via TEM

N = Negative: does not meet definition of ACM

A = Assumed to be ACM; no samples collected

Present Condition

SD = Significantly Damaged (Damage equal to or greater than 10 % distributed/ 25 % localized)

D = Damaged (Damage less than 10 distributed and less than 25 % localized)

M = Miscellaneous Materials (Refer to as "Other" materials by OSHA)

T = Thermal System Insulation (Inhibits heat transfer or prohibits condensation)

of High Concern or More Than One of Moderate Concern)

PSD = Potential for Significant Damage (One Mechanism

Potential for Future Disturbance by Contact, Vibration or Air Erosion Mechanisms

EPA AHERA Asbestos Category

Hazard Ranking  = 7 thru 1; (7 being the worst i.e. significantly damaged material)

1226 Glenhaven Drive

Table #4Asbestos ‐ Suspect Material Data Sheet

Project Name:

PD = Potential for Damage (Any One Mechanism of Moderate Concern)

LPD = Low Potential for Disturbance (All Three Mechanisms of Low Concern) 

PTP = Previously tested Positive

PTN = Previously tested Negative

HM‐03 S 5 P 2

Page 105: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

F = Friable NF= Non Friable

G = Good (Very localized damage)

S = Surfacing Material (Spray‐applied or trowel applied)

Suspect Material Category # Present Disturbance P or N P or N P or N Hazard

Material # Description (S, T, M) Samples Condition Potential PLM TEM Point Count Ranking

Asbestos Finding;                    Asbestos Containing Material (ACM) contains > 1% asbestos by definition

Project Address: 15‐Mar‐191226 Glenhaven Dr., Columbia, SC

Quantity

P = Positive via PLM

P = Positive via TEM

N = Negative: does not meet definition of ACM

A = Assumed to be ACM; no samples collected

Present Condition

SD = Significantly Damaged (Damage equal to or greater than 10 % distributed/ 25 % localized)

D = Damaged (Damage less than 10 distributed and less than 25 % localized)

M = Miscellaneous Materials (Refer to as "Other" materials by OSHA)

T = Thermal System Insulation (Inhibits heat transfer or prohibits condensation)

of High Concern or More Than One of Moderate Concern)

PSD = Potential for Significant Damage (One Mechanism

Potential for Future Disturbance by Contact, Vibration or Air Erosion Mechanisms

EPA AHERA Asbestos Category

Hazard Ranking  = 7 thru 1; (7 being the worst i.e. significantly damaged material)

1226 Glenhaven Drive

Table #4Asbestos ‐ Suspect Material Data Sheet

Project Name:

PD = Potential for Damage (Any One Mechanism of Moderate Concern)

LPD = Low Potential for Disturbance (All Three Mechanisms of Low Concern) 

PTP = Previously tested Positive

PTN = Previously tested Negative

HM‐10 Carpet Mastic M 3 270 ft2 NF/G LPD N N NA

HM‐11Exterior Window 

GlazingM 3 29 windows NF/G PD N N NA

HM‐12 Wire Wrap M 3 16 LF F/G PD N N NA

HM‐13 Exterior Caulk M 32 doors; 

29 windowsNF/G PD N N NA

HM‐14Ceramic Tile Thinset 

(Main Level)M 3 292 ft

2 F/G PD N NA

HM‐15 Interior Caulk M 311 doors; 29 

windowsNF/G PD N N NA

HM‐16 Roof Shingles M 3 2,655 ft2 NF/G PD N N NA

HM‐17Felt Paper under 

ShinglesM 3 2,655 ft

2 NF/G LPD N N NA

Page 106: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

F = Friable NF= Non Friable

G = Good (Very localized damage)

S = Surfacing Material (Spray‐applied or trowel applied)

Suspect Material Category # Present Disturbance P or N P or N P or N Hazard

Material # Description (S, T, M) Samples Condition Potential PLM TEM Point Count Ranking

Asbestos Finding;                    Asbestos Containing Material (ACM) contains > 1% asbestos by definition

Project Address: 15‐Mar‐191226 Glenhaven Dr., Columbia, SC

Quantity

P = Positive via PLM

P = Positive via TEM

N = Negative: does not meet definition of ACM

A = Assumed to be ACM; no samples collected

Present Condition

SD = Significantly Damaged (Damage equal to or greater than 10 % distributed/ 25 % localized)

D = Damaged (Damage less than 10 distributed and less than 25 % localized)

M = Miscellaneous Materials (Refer to as "Other" materials by OSHA)

T = Thermal System Insulation (Inhibits heat transfer or prohibits condensation)

of High Concern or More Than One of Moderate Concern)

PSD = Potential for Significant Damage (One Mechanism

Potential for Future Disturbance by Contact, Vibration or Air Erosion Mechanisms

EPA AHERA Asbestos Category

Hazard Ranking  = 7 thru 1; (7 being the worst i.e. significantly damaged material)

1226 Glenhaven Drive

Table #4Asbestos ‐ Suspect Material Data Sheet

Project Name:

PD = Potential for Damage (Any One Mechanism of Moderate Concern)

LPD = Low Potential for Disturbance (All Three Mechanisms of Low Concern) 

PTP = Previously tested Positive

PTN = Previously tested Negative

HM‐18 Chimney Flashing M 3 10 LF NF/G PD P 2

HM‐19Interior Insulation 

Paper at WallT 3 280 ft

2 F/G PD N N NA

HM‐20Felt Paper on Wood 

FloorsM 3 966 ft2 NF/G PD N N NA

Page 107: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

Assumed to contain Asbestos > 1%

Laboratory ABS Suspect Material Type * Percent Percent Percent

Sample # Sample # Material # Description Asbestos PLM TEM Point Count

71906367PLM_1 1226‐01 Master Bedroom Chry 3%

71906367PLM_2 1226‐02 Bedroom 2 Chry 3%

71906367PLM_3 1226‐03 Bath (Upper) Chry 3%

71906367PLM_4 1226‐04 ‐ A Master Bedroom NAD

71906367PLM_5 1226‐05 ‐ A Bedroom 2 NAD

71906367PLM_6 1226‐06 ‐ A Master Bathroom NAD

71906367PLM_64 1226‐04 ‐ B Master Bedroom Chry 3%

71906367PLM_65 1226‐05 ‐ B Bedroom 2 Chry 3%

71906367PLM_66 1226‐06 ‐ B Master Bathroom Chry 3%

71906367PLM_7 1226‐07 Bath (Lower) Chry 3%

71906367PLM_8 1226‐08 Master Bedroom Chry 3%

71906367PLM_9 1226‐09 ‐ A Bath (Lower) NAD

71906367PLM_10 1226‐10 ‐ A Den NAD

71906367PLM_11 1226‐11 ‐ A Den NAD

71906367PLM_12 1226‐12 ‐ A Utility NAD

71906367PLM_13 1226‐13 ‐ A Utility NAD

71906367PLM_59 1226‐09 ‐ B Bath (Lower) NAD

71906367PLM_60 1226‐10 ‐ B Den NAD

71906367PLM_61 1226‐11 ‐ B Den NAD

71906367PLM_62 1226‐12 ‐ B Utility NAD

71906367PLM_63 1226‐13 ‐ B Utility NAD

* Chry = Chrysotile Amos = Amosite Croc = Crocidolite Anth = Anthophylite NAD = No Asbestos Detected DNA = Did Not Analyze

Location

HM‐01 Ceiling Texture

HM‐04 Plaster: Finish

Joint CompoundHM‐03

HM‐05 Plaster: Base

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via PLM

1226 Glenhaven Drive

1226 Glenhaven Dr., Columbia, SC 15‐Mar‐19

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via TEM

Table #5Asbestos ‐ Bulk Sample Data Sheet

Project Name:

Project Address:

SheetrockHM‐02

*   NAD = No Asbestos Detected

 Amos = Amosite

DNA = Did Not Analyze

 Croc = Crocidilite

Chry = Chrysotile

Anth = Anthophylite

Page 108: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

Assumed to contain Asbestos > 1%

Laboratory ABS Suspect Material Type * Percent Percent Percent

Sample # Sample # Material # Description Asbestos PLM TEM Point Count

* Chry = Chrysotile Amos = Amosite Croc = Crocidolite Anth = Anthophylite NAD = No Asbestos Detected DNA = Did Not Analyze

Location

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via PLM

1226 Glenhaven Drive

1226 Glenhaven Dr., Columbia, SC 15‐Mar‐19

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via TEM

Table #5Asbestos ‐ Bulk Sample Data Sheet

Project Name:

Project Address:

71906367PLM_14 1226‐14 Stair Landing NAD

71906367PLM_15 1226‐15 Entry NAD

71906430TBS_1 1226‐16 Living Room NAD

71906367PLM_17 1226‐17 Crawlspace Chry 60%

71906367PLM_18 1226‐18 Crawlspace Chry 60%

71906367PLM_19 1226‐19 Crawlspace Chry 60%

71906367PLM_20 1226‐20 Living Room NAD

71906367PLM_21 1226‐21 Kitchen NAD

71906430TBS_2 1226‐22 Living Room NAD

71906367PLM_23 1226‐23 Laundry Chry 8%

71906367PLM_24 1226‐24 Laundry Chry 8%

71906367PLM_25 1226‐25 Laundry DNA

71906367PLM_26 1226‐26 NAD

71906367PLM_27 1226‐27 NAD

71906430TBS_3 1226‐28 Chry 0.80%

71906367PLM_29 1226‐29 NAD

71906367PLM_30 1226‐30 NAD

71906430TBS_4 1226‐31 NAD

71906367PLM_32 1226‐32 Living Room NAD

71906367PLM_33 1226‐33 Stair Landing NAD

71906430TBS_5 1226‐34 Kitchen NAD

HM‐09Ceramic Tile Thinset 

(Laundry)

HM‐07 Duct Tape

Interior Felt Paper

HM‐10 Carpet Mastic

HM‐06 Silver Paint

HM‐08

HM‐11 Exterior Window Glazing

HM‐12 Wire Wrap

Den

*   NAD = No Asbestos Detected

 Amos = Amosite

DNA = Did Not Analyze

 Croc = Crocidilite

Chry = Chrysotile

Anth = Anthophylite

Page 109: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

Assumed to contain Asbestos > 1%

Laboratory ABS Suspect Material Type * Percent Percent Percent

Sample # Sample # Material # Description Asbestos PLM TEM Point Count

* Chry = Chrysotile Amos = Amosite Croc = Crocidolite Anth = Anthophylite NAD = No Asbestos Detected DNA = Did Not Analyze

Location

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via PLM

1226 Glenhaven Drive

1226 Glenhaven Dr., Columbia, SC 15‐Mar‐19

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via TEM

Table #5Asbestos ‐ Bulk Sample Data Sheet

Project Name:

Project Address:

71906367PLM_35 1226‐35 NAD

71906367PLM_36 1226‐36 NAD

71906430TBS_6 1226‐37 NAD

71906367PLM_38 1226‐38 NAD

71906367PLM_39 1226‐39 NAD

71906367PLM_40 1226‐40 NAD

71906367PLM_41 1226‐41 Laundry NAD

71906367PLM_42 1226‐42 Entry NAD

71906430TBS_7 1226‐43 Stair Landing NAD

71906367PLM_44 1226‐44 NAD

71906367PLM_45 1226‐45 NAD

71906430TBS_8 1226‐46 NAD

71906367PLM_47 1226‐47 NAD

71906367PLM_48 1226‐48 NAD

71906430TBS_9 1226‐49 NAD

71906367PLM_50 1226‐50 Chry 5%

71906367PLM_51 1226‐51 Chry 5%

71906367PLM_52 1226‐52 DNA

71906367PLM_53 1226‐53 Living Room NAD

71906367PLM_54 1226‐54 Stair Landing NAD

71906430TBS_10 1226‐55 Bath (Upper) NAD

HM‐13 Exterior Caulk

HM‐14Ceramic Tile Thinset 

(Main Level)Kitchen

HM‐19Interior Insulation Paper 

at Wall

HM‐17 Felt Paper under Shingles Roof

HM‐18 Chimney Flashing

HM‐15 Interior Caulk

HM‐16 Shingles Roof

*   NAD = No Asbestos Detected

 Amos = Amosite

DNA = Did Not Analyze

 Croc = Crocidilite

Chry = Chrysotile

Anth = Anthophylite

Page 110: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

Assumed to contain Asbestos > 1%

Laboratory ABS Suspect Material Type * Percent Percent Percent

Sample # Sample # Material # Description Asbestos PLM TEM Point Count

* Chry = Chrysotile Amos = Amosite Croc = Crocidolite Anth = Anthophylite NAD = No Asbestos Detected DNA = Did Not Analyze

Location

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via PLM

1226 Glenhaven Drive

1226 Glenhaven Dr., Columbia, SC 15‐Mar‐19

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via TEM

Table #5Asbestos ‐ Bulk Sample Data Sheet

Project Name:

Project Address:

71906367PLM_55 1226‐56 Living Room NAD

71906367PLM_56 1226‐57 Living Room NAD

71906430TBS_11 1226‐58 Living Room NAD

HM‐20 Felt Paper on Wood Floor

*   NAD = No Asbestos Detected

 Amos = Amosite

DNA = Did Not Analyze

 Croc = Crocidilite

Chry = Chrysotile

Anth = Anthophylite

Page 111: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

1226 Glenhaven Dr ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19013

LABORATORY RESULTS

Page 112: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

1226 GlenhavenProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71906367_PLM

Date Reported: 3/9/2019

Date Received: 3/8/2019

Lab Order ID: 71906367

3% Chrysotile

1226-01Ceiling Texture

GrayNon FibrousHomogeneous

Teased71906367PLM_1

Other 97%

3% Chrysotile

1226-02Ceiling Texture

GrayNon FibrousHomogeneous

Teased71906367PLM_2

Other 97%

3% Chrysotile

1226-03Ceiling Texture

GrayNon FibrousHomogeneous

Teased71906367PLM_3

Other 97%

< 1% Chrysotile

1226-04Sheetrock/Joint Compound

sheetrock: none detect; jointcompnd: none detect

Brown, GrayNon FibrousHeterogeneous

Teased71906367PLM_4

Cellulose Other 10% 90%

< 1% Chrysotile

1226-05Sheetrock/Joint Compound

sheetrock: none detect; jointcompnd: none detect

Brown, GrayNon FibrousHeterogeneous

Teased71906367PLM_5

Cellulose Other 10% 90%

< 1% Chrysotile

1226-06Sheetrock/Joint Compound

sheetrock: none detect; jointcompnd: none detect

Brown, GrayNon FibrousHeterogeneous

Teased71906367PLM_6

Cellulose Other 10% 90%

3% Chrysotile

1226-07Joint Compound

GrayNon FibrousHomogeneous

Teased71906367PLM_7

Other 97%

3% Chrysotile

1226-08Joint Compound

GrayNon FibrousHomogeneous

Teased71906367PLM_8

Other 97%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 1 of 8

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Byron Stroble (63)

P-F-002 r15 1/16/2021

Page 113: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

1226 GlenhavenProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71906367_PLM

Date Reported: 3/9/2019

Date Received: 3/8/2019

Lab Order ID: 71906367

None Detected1226-09 - A

Plaster

finish

WhiteNon FibrousHomogeneous

Teased71906367PLM_9

Other 100%

None Detected1226-09 - B

Plaster

base

GrayNon FibrousHomogeneous

Crushed71906367PLM_59

Other 100%

None Detected1226-10 - A

Plaster

finish

WhiteNon FibrousHomogeneous

Teased71906367PLM_10

Other 100%

None Detected1226-10 - B

Plaster

base

GrayNon FibrousHomogeneous

Crushed71906367PLM_60

Other 100%

None Detected1226-11 - A

Plaster

finish

WhiteNon FibrousHomogeneous

Teased71906367PLM_11

Other 100%

None Detected1226-11 - B

Plaster

base

GrayNon FibrousHomogeneous

Crushed71906367PLM_61

Other 100%

None Detected1226-12 - A

Plaster

finish

WhiteNon FibrousHomogeneous

Teased71906367PLM_12

Other 100%

None Detected1226-12 - B

Plaster

base

GrayNon FibrousHomogeneous

Crushed71906367PLM_62

Other 100%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 2 of 8

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Byron Stroble (63)

P-F-002 r15 1/16/2021

Page 114: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

1226 GlenhavenProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71906367_PLM

Date Reported: 3/9/2019

Date Received: 3/8/2019

Lab Order ID: 71906367

None Detected1226-13 - A

Plaster

finish

WhiteNon FibrousHomogeneous

Teased71906367PLM_13

Other 100%

None Detected1226-13 - B

Plaster

base

GrayNon FibrousHomogeneous

Crushed71906367PLM_63

Other 100%

None Detected1226-14

Silver PaintBlack, SilverNon FibrousHeterogeneous

Dissolved71906367PLM_14

Other 100%

None Detected1226-15

Silver PaintBlack, SilverNon FibrousHeterogeneous

Dissolved71906367PLM_15

Other 100%

Not Analyzed1226-16

Silver Paint

TEM71906367PLM_16

60% Chrysotile

1226-17Duct Tape

GrayFibrousHomogeneous

Teased71906367PLM_17

Cellulose Other 30% 10%

60% Chrysotile

1226-18Duct Tape

GrayFibrousHomogeneous

Teased71906367PLM_18

Cellulose Other 30% 10%

60% Chrysotile

1226-19Duct Tape

GrayFibrousHomogeneous

Teased71906367PLM_19

Cellulose Other 30% 10%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 3 of 8

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Byron Stroble (63)

P-F-002 r15 1/16/2021

Page 115: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

1226 GlenhavenProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71906367_PLM

Date Reported: 3/9/2019

Date Received: 3/8/2019

Lab Order ID: 71906367

None Detected1226-20

Interior Felt PaperGray, BlackFibrousHeterogeneous

Teased, Dissolved71906367PLM_20

Cellulose Other 80% 20%

None Detected1226-21

Interior Felt PaperGray, BlackFibrousHeterogeneous

Teased, Dissolved71906367PLM_21

Cellulose Other 80% 20%

Not Analyzed1226-22

Interior Felt Paper

TEM71906367PLM_22

8% Chrysotile

1226-23Ceramic Tile Thinset (LowerLevel)

Brown, BlackNon FibrousHeterogeneous

Dissolved71906367PLM_23

Other 92%

8% Chrysotile

1226-24Ceramic Tile Thinset (LowerLevel)

Brown, BlackNon FibrousHeterogeneous

Dissolved71906367PLM_24

Other 92%

Not Analyzed1226-25

Ceramic Tile Thinset (LowerLevel)

71906367PLM_25

None Detected1226-26

Carpet MasticYellowNon FibrousHomogeneous

Dissolved71906367PLM_26

Other 100%

None Detected1226-27

Carpet MasticYellowNon FibrousHomogeneous

Dissolved71906367PLM_27

Other 100%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 4 of 8

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Byron Stroble (63)

P-F-002 r15 1/16/2021

Page 116: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

1226 GlenhavenProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71906367_PLM

Date Reported: 3/9/2019

Date Received: 3/8/2019

Lab Order ID: 71906367

Not Analyzed1226-28

Carpet Mastic

TEM71906367PLM_28

None Detected1226-29

Exterior Window GlazingWhiteNon FibrousHomogeneous

Ashed, Dissolved71906367PLM_29

Other 100%

None Detected1226-30

Exterior Window GlazingWhiteNon FibrousHomogeneous

Ashed, Dissolved71906367PLM_30

Other 100%

Not Analyzed1226-31

Exterior Window Glazing

TEM71906367PLM_31

None Detected1226-32

Wire InsulationBrown, BlackFibrousHeterogeneous

Teased, Dissolved71906367PLM_32

Fiber Glass Other 30% 70%

None Detected1226-33

Wire InsulationBrown, BlackFibrousHeterogeneous

Teased, Dissolved71906367PLM_33

Fiber Glass Other 30% 70%

Not Analyzed1226-34

Wire Insulation

TEM71906367PLM_34

None Detected1226-35

Exterior CaulkWhiteNon FibrousHomogeneous

Ashed71906367PLM_35

Other 100%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 5 of 8

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Byron Stroble (63)

P-F-002 r15 1/16/2021

Page 117: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

1226 GlenhavenProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71906367_PLM

Date Reported: 3/9/2019

Date Received: 3/8/2019

Lab Order ID: 71906367

None Detected1226-36

Exterior CaulkGreenNon FibrousHomogeneous

Ashed71906367PLM_36

Other 100%

Not Analyzed1226-37

Exterior Caulk

TEM71906367PLM_37

None Detected1226-38

Ceramic Tile Thinset (MainLevel)

GrayNon FibrousHomogeneous

Crushed71906367PLM_38

Other 100%

None Detected1226-39

Ceramic Tile Thinset (MainLevel)

GrayNon FibrousHomogeneous

Crushed71906367PLM_39

Other 100%

None Detected1226-40

Ceramic Tile Thinset (MainLevel)

GrayNon FibrousHomogeneous

Crushed71906367PLM_40

Other 100%

None Detected1226-41

Interior CaulkWhiteNon FibrousHomogeneous

Ashed71906367PLM_41

Other 100%

None Detected1226-42

Interior CaulkWhiteNon FibrousHomogeneous

Ashed71906367PLM_42

Other 100%

Not Analyzed1226-43

Interior Caulk

TEM71906367PLM_43

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 6 of 8

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Byron Stroble (63)

P-F-002 r15 1/16/2021

Page 118: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

1226 GlenhavenProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71906367_PLM

Date Reported: 3/9/2019

Date Received: 3/8/2019

Lab Order ID: 71906367

None Detected1226-44

Roof ShinglesBlackNon FibrousHomogeneous

Dissolved71906367PLM_44

Cellulose Other 10% 90%

None Detected1226-45

Roof ShinglesBlackNon FibrousHomogeneous

Dissolved71906367PLM_45

Cellulose Other 10% 90%

Not Analyzed1226-46

Roof Shingles

TEM71906367PLM_46

None Detected1226-47

Felt Paper under ShinglesBlackFibrousHomogeneous

Teased, Dissolved71906367PLM_47

Cellulose Other 70% 30%

None Detected1226-48

Felt Paper under ShinglesBlackFibrousHomogeneous

Teased, Dissolved71906367PLM_48

Cellulose Other 70% 30%

Not Analyzed1226-49

Felt Paper under Shingles

TEM71906367PLM_49

5% Chrysotile

1226-50Chimney Flashing

BlackNon FibrousHomogeneous

Dissolved71906367PLM_50

Other 95%

5% Chrysotile

1226-51Chimney Flashing

BlackNon FibrousHomogeneous

Dissolved71906367PLM_51

Other 95%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 7 of 8

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Byron Stroble (63)

P-F-002 r15 1/16/2021

Page 119: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

1226 GlenhavenProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71906367_PLM

Date Reported: 3/9/2019

Date Received: 3/8/2019

Lab Order ID: 71906367

Not Analyzed1226-52

Chimney Flashing

71906367PLM_52

None Detected1226-53

Interior Insulation Paper atWall

Brown, BlackNon FibrousHomogeneous

Dissolved71906367PLM_53

Cellulose Other 40% 60%

None Detected1226-54

Interior Insulation Paper atWall

Brown, BlackNon FibrousHomogeneous

Dissolved71906367PLM_54

Cellulose Other 40% 60%

Not Analyzed1226-55

Interior Insulation Paper atWall

TEM71906367PLM_55

None Detected1226-56

Felt Paper on Wood FloorBlackFibrousHomogeneous

Teased, Dissolved71906367PLM_56

Cellulose Other 70% 30%

None Detected1226-57

Felt Paper on Wood FloorBlackFibrousHomogeneous

Teased, Dissolved71906367PLM_57

Cellulose Other 70% 30%

Not Analyzed1226-58

Felt Paper on Wood Floor

TEM71906367PLM_58

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 8 of 8

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Byron Stroble (63)

P-F-002 r15 1/16/2021

Page 120: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Client: .;,,.;~p tr:

~~ntt,ct: Address: _ ~ rnl

,Ph'l>ne: ·<v@ Fax: Email:

Projept: Bi:

CllenJNoty:

ABS ENVIRONMENTAL JEFF RIVERS 1416 CHAPIN RD.-CHAPIN, SC 803-260-2883 803-345-2823 J RIVERS@ABSENV. COM

1226 Glenhaven

72 HR TAT for TEM NOB

P.p. #. 0 41 '[Enter P.O. # Here] Date Submitted: 3/7/2019 0:00

Analysts: IEPA PLM 600 TumAroundTlme: 24 HR TAT

!Sample Number <<

1226-01 1226-02 1226-03 1226-04 1226-05 1226-06 1226-07 1226-08 1226-09 1226-10 1226-11 1226-12 1226-13 1226-14 1226-15 1226-16 1226-17 1226-18

Relinquished By

Data.1

[Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here]

Ta See aii ExatrJp/e Qlic/5 the , ,& ·.. , $ .· •ix ,/j

bottom Example Tab;

"'Entef samples between "<<~a,td ">>I ,ffi Begln Samples wlth''a :<< "above the'f/rst ~ample

i1 and end-with a ">>" below the last sample. Only Enter your data on°the. first sheet uSh91:1t1,~

W \% , Fi ffi r,Jote: Qata 1 and.Data. 2 are optional

fie,ld\ th1t do not.§h0W up on the*pffiial report, however they will be includea in the~electronic data returned to you

to facilitate*yotir reintegration of the feoorl data.

Sample Description

Ceiling Texture Ceiling Texture Ceiling Texture Sheetrock/Joint Compound Sheetrock/Joint Compound Sheetrock/Joint Compound Joint Compound Joint Compound Plaster Plaster

'1 I C,O(.p3<:o'l

Institute

4604 Dundas. Drive Greensboro, NC 27407 Phone: 336.292.3888

Fax: 336.292.3313 Email: [email protected]

Data2

[Enter data of your choosing here) [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here) [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here]

Plaster Plaster Plaster Silver Paint Silver Paint

~Enter data of your choosing here]

Accepted

Rejected 0 Silver Paint Duct Tape Duct Tape

~ ~ 3' s Received By

10~ 30 1\-\ v\

Page 121: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

r-[[°JDlo~lo I

1226-19 Duct Tape 1226-20 Interior Felt Paper 1226-21 Interior Felt Paper 1226-22 Interior Felt Paper TEM NOB If Negative

1226-23 Ceramic Tile Thinset (Lower Level) 1226-24 Ceramic Tile Thinset (Lower Level) 1226-25 Ceramic Tile Thinset (Lower Level) 1226-26 Carpet Mastic 1226-27 Carpet Mastic 1226-28 Carpet Mastic TEM NOB If Negative

1226-29 Exterior Window Glazing 1226-30 Exterior Window Glazing 1226-31 Exterior Window Glazing TEM NOB If Negative

1226-32 Wire Insulation 1226-33 Wire Insulation 1226-34 Wire Insulation 1226-35 Exterior Caulk 1226-36 Exterior Caulk 1226-37 Exterior Caulk TEM NOB If Negative

1226-38 Ceramic Tile Thinset (Main Level)

1226-39 Ceramic Tile Thinset (Main Level) 1226-40 Ceramic Tile Thinset (Main Level)

1226-41 Interior Caulk 1226-42 Interior Caulk 1226-43 Interior Caulk TEM NOB If Negative

1226-44 Roof Shingles 1226-45 Roof Shingles 1226-46 Roof Shingles TEM NOB If Negative

1226-47 Felt Paper under Shingles 1226-48 Felt Paper under Shingles

1226-49 Felt Paper under Shingles TEM NOB If Negative

1226-50 Chimney Flashing 1226-51 Chimney Flashing 1226-52 Chimney Flashing TEM NOB If Negative

1226-53 Interior Insulation Paper at Wall 1226-54 Interior Insulation Paper at Wall

1226-55 Interior Insulation Paper at Wall TEM NOB If Negative

Relinquished By Received By

Page 122: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

1226-56 1226-57 1226-58 >>

Relinquished By

Felt Paper on Wood Floor Felt Paper on Wood Floor Felt Paper on Wood Floor

1,0,0~ s(f,

TEM NOB If Negative

Received By

Page 123: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

3/11/2019Project: 1226 Glenhaven

Lab Order ID: 71906430

Lab Notes

Description

Lab Sample ID

Sample ID

Semi-QuantitativeChatfield SOP 1988-02 Rev. 1

Asbestos LCL-UCL

(Wt. %)

Bulk Asbestos Analysisby Transmission Electron Microscopy

Date Received:

3/14/2019Date Reported:

ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Customer:

Analysis ID: 71906430_TB

Attn: Jeff Rivers

Acid Sol.

Organic

(Wt. %)(Wt. %) (Wt. %)

None Detected-79%1226-16

71906430TBS_1

Silver paint

None Detected-95%1226-22

71906430TBS_2

Interior felt paper

-20.%1226-28

71906430TBS_3

Carpet mastic0.72% - 0.88%Chrysotile0.80 %

None Detected78%14%1226-31

71906430TBS_4

Exterior window glazing

None Detected-64%1226-34

71906430TBS_5

Wire insulation

None Detected-26%1226-37

71906430TBS_6

Exterior caulk

Russell Shelton (11)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Approved SignatoryPage 1 of 2tem_2.2.001

Analyst

Disclaimer: This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

T-F-010 r15 1/15/2018

Page 124: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

3/11/2019Project: 1226 Glenhaven

Lab Order ID: 71906430

Lab Notes

Description

Lab Sample ID

Sample ID

Semi-QuantitativeChatfield SOP 1988-02 Rev. 1

Asbestos LCL-UCL

(Wt. %)

Bulk Asbestos Analysisby Transmission Electron Microscopy

Date Received:

3/14/2019Date Reported:

ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Customer:

Analysis ID: 71906430_TB

Attn: Jeff Rivers

Acid Sol.

Organic

(Wt. %)(Wt. %) (Wt. %)

None Detected-42%1226-43

71906430TBS_7

Interior caulk

None Detected-19%1226-46

71906430TBS_8

Roof shingles

None Detected-96%1226-49

71906430TBS_9

Felt paper under shingles

None Detected-89%1226-55

71906430TBS_10

Interior insulation paper at wall

None Detected-94%1226-58

71906430TBS_11

Felt paper on wood floor

Russell Shelton (11)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Approved SignatoryPage 2 of 2tem_2.2.001

Analyst

Disclaimer: This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

T-F-010 r15 1/15/2018

Page 125: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011
Page 126: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011
Page 127: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011
Page 128: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Prepared

Prepared

Inspectio

Report P

Report R

d for:

d by:

on Performed

repared by:

Reviewed by

1238

City of CoAttn: Dav1136 WasColumbia

ABS Envi1416 ChapChapin, SABS Job #

d by:

:

Mar

Asbes

8 Glenhaven

olumbiavid Hatchershington Stra, SC 29201

ironmental,pin Road

SC 29036# 7800.1901

Jeff R

Jeff R

Lee C

ch 15, 201

stos SurvFor

n Drive, Co

reet

, Inc.

14

Rivers

Rivers

Capell

19

vey

olumbia, SC

P

P

SCDMP –

SCDMP –

SCDMP –

C

Phone: (803

Phone: (803

DHEC # – 00166

DHEC # – 00166

DHEC # – 00072

3) 545-3444

3) 345-3833

Lic Exp D8/1/19

Lic Exp D8/1/19

Lic Exp D8/8/19

Date

Date

Date

Page 129: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

1238 Glenhaven Dr ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19014

TABLE OF CONTENTS

1.0 EXECUTIVE SUMMARY

2.0 APPENDIX

A. Drawing

B. Site Map

C. Tables

D. Laboratory Results

Page 130: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

1238 Glenhaven Dr ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19014

1.0 EXECUTIVE SUMMARY

ABS Environmental, Inc. (ABS) was retained by the City of Columbia to perform an asbestos survey at 1238 Glenhaven Drive in Columbia, SC. The primary objective of this survey was to identify, sample and physically assess suspect asbestos-containing building materials (ACBM) associated with the vacant residence. The subject structure is a single-family residence built over a crawlspace. The roof is built in an intersecting hip configuration and is covered with architectural grade shingles. The exterior is clad primarily with brick veneer. Interior finishes include: Ceilings/Walls: Plaster over sheetrock. Floors: Combination of ceramic tile and wood floors. Vinyl flooring is in the office. Fourteen (14) suspect materials were identified, sampled and analyzed for the presence of asbestos. Samples were delivered by overnight courier service to SAI, Inc. for analysis using Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM) to confirm negative PLM results for non-friable organically bound materials. As indicated by laboratory analysis, those materials containing asbestos > 1 % include approximately:

132 ft2 of sheet vinyl in the Office.

170 LF of duct tape in the Office.

Exterior caulk around 14 windows and 3 doors.

12 LF of chimney flashing. Limitations This survey and report have been executed at the request of Mr. David Hatcher and City of Columbia and are intended solely for their use. All work related to this project has been conducted in keeping with accepted standards of environmental consulting as practiced in the State of South Carolina. No unnecessary destructive measures were undertaken during this survey. Additional suspect and/or asbestos containing materials may be present. If at any time during the course of renovation or demolition a suspect material is observed that is not identified in this report, stop work immediately until the material can be sampled and analyzed for the presence of asbestos. ABS has relied, in part, on information derived from secondary sources, and except as set forth herein, ABS has made no independent investigation as to the accuracy or completeness of the information derived from such secondary sources. No warranty is expressed or implied.

Page 131: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

1238 Glenhaven Dr ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19014

DRAWING

Page 132: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011
Page 133: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

1238 Glenhaven Dr ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19014

SITE MAP

Page 134: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

1238 Glenhaven Dr ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19014

TABLES

Page 135: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

*  Assumed to Contain Asbestos > 1%

Chimney Flashing Miscellaneous 12 LF

Duct Tape Miscellaneous 170 LF

Exterior Caulk Miscellaneous 3 Doors; 14 Windows

Table #1Asbestos Containing Building Material (ACBM)

Project Name: 1238 Glenhaven Drive

Project Address: 1238 Glenhaven Dr., Columbia, SC 15‐Mar‐19

Observed ACBMMaterial EPA AHERA Category Quantity

Sheet Vinyl Miscellaneous 132 ft2

Page 136: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

*  Assumed to Contain Asbestos > 1%

Chimney Flashing 12 LF

Exterior Caulk 3 Doors; 14 Windows

Duct Tape 170 LF

Table #2Non‐Friable ACBM

Project Name: 1238 Glenhaven Drive

Project Address: 1238 Glenhaven Dr., Columbia, SC 15‐Mar‐19

Non‐Friable ACBM

Material Quantity

Sheet Vinyl 132 ft2

Page 137: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

F = Friable NF= Non Friable

G = Good (Very localized damage)

S = Surfacing Material (Spray‐applied or trowel applied)

Suspect Material Category # Present Disturbance P or N P or N P or N Hazard

Material # Description (S, T, M) Samples Condition Potential PLM TEM Point Count Ranking

HM‐01 Plaster: Finish S 5 1,767 ft2 F/G PD N NA

HM‐02 Plaster: Base S 5 1,767 ft2 F/G PD N NA

HM‐03Joint Compound on 

PlasterS 5 1,767 ft

2 F/G PD N NA

HM‐04Sheetrock behind 

PlasterM 3 1,767 ft

2 F/G PD N NA

HM‐05Mastic under Ceramic 

Tile (Floors/Walls)M 3 448 ft

2 NF/G LPD N N NA

HM‐06 Black Floor Mastic M 3 355 ft2 NF/G PD N N NA

HM‐07 Sheet Vinyl M 3 132 ft2 NF/G PD P 2

HM‐08 Duct Tape M 3 170 LF NF/G PD P 2

1238 Glenhaven Drive

Table #3Asbestos ‐ Suspect Material Data Sheet

Project Name:

PD = Potential for Damage (Any One Mechanism of Moderate Concern)

LPD = Low Potential for Disturbance (All Three Mechanisms of Low Concern) 

PTP = Previously tested Positive

PTN = Previously tested Negative

Quantity

P = Positive via PLM

P = Positive via TEM

N = Negative: does not meet definition of ACM

A = Assumed to be ACM; no samples collected

Present Condition

SD = Significantly Damaged (Damage equal to or greater than 10 % distributed/ 25 % localized)

D = Damaged (Damage less than 10 distributed and less than 25 % localized)

M = Miscellaneous Materials (Refer to as "Other" materials by OSHA)

T = Thermal System Insulation (Inhibits heat transfer or prohibits condensation)

of High Concern or More Than One of Moderate Concern)

PSD = Potential for Significant Damage (One Mechanism

Potential for Future Disturbance by Contact, Vibration or Air Erosion Mechanisms

EPA AHERA Asbestos Category

Hazard Ranking  = 7 thru 1; (7 being the worst i.e. significantly damaged material)

Asbestos Finding;                    Asbestos Containing Material (ACM) contains > 1% asbestos by definition

Project Address: 15‐Mar‐191238 Glenhaven Dr., Columbia, SC

Page 138: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

F = Friable NF= Non Friable

G = Good (Very localized damage)

S = Surfacing Material (Spray‐applied or trowel applied)

Suspect Material Category # Present Disturbance P or N P or N P or N Hazard

Material # Description (S, T, M) Samples Condition Potential PLM TEM Point Count Ranking

1238 Glenhaven Drive

Table #3Asbestos ‐ Suspect Material Data Sheet

Project Name:

PD = Potential for Damage (Any One Mechanism of Moderate Concern)

LPD = Low Potential for Disturbance (All Three Mechanisms of Low Concern) 

PTP = Previously tested Positive

PTN = Previously tested Negative

Quantity

P = Positive via PLM

P = Positive via TEM

N = Negative: does not meet definition of ACM

A = Assumed to be ACM; no samples collected

Present Condition

SD = Significantly Damaged (Damage equal to or greater than 10 % distributed/ 25 % localized)

D = Damaged (Damage less than 10 distributed and less than 25 % localized)

M = Miscellaneous Materials (Refer to as "Other" materials by OSHA)

T = Thermal System Insulation (Inhibits heat transfer or prohibits condensation)

of High Concern or More Than One of Moderate Concern)

PSD = Potential for Significant Damage (One Mechanism

Potential for Future Disturbance by Contact, Vibration or Air Erosion Mechanisms

EPA AHERA Asbestos Category

Hazard Ranking  = 7 thru 1; (7 being the worst i.e. significantly damaged material)

Asbestos Finding;                    Asbestos Containing Material (ACM) contains > 1% asbestos by definition

Project Address: 15‐Mar‐191238 Glenhaven Dr., Columbia, SC

HM‐09 Wire Wrap M 3 15 LF F/G PD N N NA

HM‐10Felt Paper under 

Hardwood FloorM 3 1,597 ft

2 NF/G LPD N N NA

HM‐11 Exterior Caulk M 33 doors

14 windowsNF/G PD P 2

HM‐12 Roof Shingles M 3 2,660 ft2 NF/G PD N N NA

HM‐13Felt Paper under 

ShinglesM 3 2,660 ft

2 NF/G LPD N N NA

HM‐14 Chimney Flashing M 3 12 LF NF/G PD P 2

Page 139: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

Assumed to contain Asbestos > 1%

Laboratory ABS Suspect Material Type * Percent Percent Percent

Sample # Sample # Material # Description Asbestos PLM TEM Point Count

71906362PLM_1 1238‐01 ‐ A Kitchen NAD

71906362PLM_2 1238‐02 ‐ A Living Room NAD

71906362PLM_3 1238‐03 ‐ A Hallway NAD

71906362PLM_4 1238‐04 ‐ A Bathroom NAD

71906362PLM_5 1238‐05 ‐ A Master Bedroom NAD

71906362PLM_44 1238‐01 ‐ B Kitchen NAD

71906362PLM_45 1238‐02 ‐ B Living Room NAD

71906362PLM_46 1238‐03 ‐ B Hallway NAD

71906362PLM_47 1238‐04 ‐ B Bathroom NAD

71906362PLM_48 1238‐05 ‐ B Master Bedroom NAD

71906362PLM_6 1238‐06 Kitchen NAD

71906362PLM_7 1238‐07 Living Room NAD

71906362PLM_8 1238‐08 Hallway NAD

71906362PLM_9 1238‐09 Bathroom NAD

71906362PLM_10 1238‐10 Master Bedroom NAD

71906362PLM_11 1238‐11 Kitchen NAD

71906362PLM_12 1238‐12 Hallway NAD

71906362PLM_13 1238‐13 Master Bedroom NAD

71906362PLM_14 1238‐14 Bathroom NAD

71906362PLM_15 1238‐15 Bathroom NAD

71906427TBS_1 1238‐16 Master Bath NAD

Table #4Asbestos ‐ Bulk Sample Data Sheet

Project Name:

Project Address:

HM‐05Mastic under Ceramic Tile 

(Floors/Walls)

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via PLM

1238 Glenhaven Drive

1238 Glenhaven Dr., Columbia, SC 15‐Mar‐19

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via TEM

Plaster: BaseHM‐02

* Chry = Chrysotile Amos = Amosite Croc = Crocidolite Anth = Anthophylite NAD = No Asbestos Detected DNA = Did Not Analyze

Location

HM‐01 Plaster: Finish

HM‐04 Sheetrock behind Plaster

Joint Compound on 

PlasterHM‐03

*   NAD = No Asbestos Detected

 Amos = Amosite

DNA = Did Not Analyze

 Croc = Crocidilite

Chry = Chrysotile

Anth = Anthophylite

Page 140: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

Assumed to contain Asbestos > 1%

Laboratory ABS Suspect Material Type * Percent Percent Percent

Sample # Sample # Material # Description Asbestos PLM TEM Point Count

Table #4Asbestos ‐ Bulk Sample Data Sheet

Project Name:

Project Address:

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via PLM

1238 Glenhaven Drive

1238 Glenhaven Dr., Columbia, SC 15‐Mar‐19

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via TEM

* Chry = Chrysotile Amos = Amosite Croc = Crocidolite Anth = Anthophylite NAD = No Asbestos Detected DNA = Did Not Analyze

Location

71906362PLM_17 1238‐17 Kitchen NAD

71906362PLM_18 1238‐18 Kitchen NAD

71906427TBS_2 1238‐19 Kitchen NAD

71906362PLM_20 1238‐20 Office Chry 15%

71906362PLM_21 1238‐21 Office Chry 15%

71906362PLM_22 1238‐22 Office DNA

71906362PLM_23 1238‐23 Crawlspace Chry 60%

71906362PLM_24 1238‐24 Crawlspace Chry 60%

71906362PLM_25 1238‐25 Crawlspace Chry 60%

71906362PLM_26 1238‐26 Hallway NAD

71906362PLM_27 1238‐27 Kitchen NAD

71906427TBS_9 1238‐28 Bathroom NAD

71906362PLM_29 1238‐29 Living Room NAD

71906362PLM_30 1238‐30 Bedroom 2 NAD

71906427TBS_4 1238‐31 Hallway NAD

71906362PLM_32 1238‐32 Outside Chry 3%

71906362PLM_33 1238‐33 Outside Chry 3%

71906362PLM_34 1238‐34 Outside DNA

71906362PLM_35 1238‐35 NAD

71906362PLM_36 1238‐36 NAD

71906427TBS_5 1238‐37 NAD

HM‐11 Exterior Caulk

HM‐12 Shingles

HM‐10Felt Paper under 

Hardwood Floors

HM‐06 Black Floor Mastic

HM‐08

Roof

HM‐09 Wire Wrap

HM‐07 Sheet Vinyl

Duct Tape

*   NAD = No Asbestos Detected

 Amos = Amosite

DNA = Did Not Analyze

 Croc = Crocidilite

Chry = Chrysotile

Anth = Anthophylite

Page 141: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

   Date:

Assumed to contain Asbestos > 1%

Laboratory ABS Suspect Material Type * Percent Percent Percent

Sample # Sample # Material # Description Asbestos PLM TEM Point Count

Table #4Asbestos ‐ Bulk Sample Data Sheet

Project Name:

Project Address:

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via PLM

1238 Glenhaven Drive

1238 Glenhaven Dr., Columbia, SC 15‐Mar‐19

Positive; meets definition of Asbestos Containing Material (ACM) (i.e.>1%asbestos) via TEM

* Chry = Chrysotile Amos = Amosite Croc = Crocidolite Anth = Anthophylite NAD = No Asbestos Detected DNA = Did Not Analyze

Location

71906362PLM_38 1238‐38 NAD

71906362PLM_39 1238‐39 NAD

71906427TBS_7 1238‐40 NAD

71906362PLM_41 1238‐41 Roof Chry 5%

71906362PLM_42 1238‐42 Roof Chry 5%

71906362PLM_43 1238‐43 Roof DNA

HM‐13 Felt Paper under Shingles

HM‐14 Chimney Flashing

Roof

*   NAD = No Asbestos Detected

 Amos = Amosite

DNA = Did Not Analyze

 Croc = Crocidilite

Chry = Chrysotile

Anth = Anthophylite

Page 142: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

1238 Glenhaven Dr ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19014

LABORATORY RESULTS

Page 143: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

1238 GlenhavenProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71906362_PLM

Date Reported: 3/8/2019

Date Received: 3/8/2019

Lab Order ID: 71906362

None Detected1238-01 - A

Plaster

finish

WhiteNon FibrousHomogeneous

Teased71906362PLM_1

Other 100%

None Detected1238-01 - B

Plaster

base

GrayNon FibrousHomogeneous

Crushed71906362PLM_44

Other 100%

None Detected1238-02 - A

Plaster

finish

WhiteNon FibrousHomogeneous

Teased71906362PLM_2

Other 100%

None Detected1238-02 - B

Plaster

base

GrayNon FibrousHomogeneous

Crushed71906362PLM_45

Other 100%

None Detected1238-03 - A

Plaster

finish

WhiteNon FibrousHomogeneous

Teased71906362PLM_3

Other 100%

None Detected1238-03 - B

Plaster

base

GrayNon FibrousHomogeneous

Crushed71906362PLM_46

Other 100%

None Detected1238-04 - A

Plaster

finish

WhiteNon FibrousHomogeneous

Teased71906362PLM_4

Other 100%

None Detected1238-04 - B

Plaster

base

GrayNon FibrousHomogeneous

Crushed71906362PLM_47

Other 100%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 1 of 6

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Byron Stroble (48)

P-F-002 r15 1/16/2021

Page 144: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

1238 GlenhavenProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71906362_PLM

Date Reported: 3/8/2019

Date Received: 3/8/2019

Lab Order ID: 71906362

None Detected1238-05 - A

Plaster

finish

WhiteNon FibrousHomogeneous

Teased71906362PLM_5

Other 100%

None Detected1238-05 - B

Plaster

base

GrayNon FibrousHomogeneous

Crushed71906362PLM_48

Other 100%

None Detected1238-06

Joint Compound on PlasterWhiteNon FibrousHomogeneous

Teased71906362PLM_6

Other 100%

None Detected1238-07

Joint Compound on PlasterWhiteNon FibrousHomogeneous

Teased71906362PLM_7

Other 100%

None Detected1238-08

Joint Compound on PlasterWhiteNon FibrousHomogeneous

Teased71906362PLM_8

Other 100%

None Detected1238-09

Joint Compound on PlasterWhiteNon FibrousHomogeneous

Teased71906362PLM_9

Other 100%

None Detected1238-10

Joint Compound on PlasterWhiteNon FibrousHomogeneous

Teased71906362PLM_10

Other 100%

None Detected1238-11

Sheetrock behind PlasterBrown, WhiteNon FibrousHomogeneous

Crushed71906362PLM_11

Other 100%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 2 of 6

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Byron Stroble (48)

P-F-002 r15 1/16/2021

Page 145: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

1238 GlenhavenProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71906362_PLM

Date Reported: 3/8/2019

Date Received: 3/8/2019

Lab Order ID: 71906362

None Detected1238-12

Sheetrock behind PlasterBrown, WhiteNon FibrousHomogeneous

Teased71906362PLM_12

Cellulose Other 10% 90%

None Detected1238-13

Sheetrock behind PlasterBrown, WhiteNon FibrousHomogeneous

Teased71906362PLM_13

Cellulose Other 10% 90%

None Detected1238-14

Mastic under Ceramic Tile(Floors/Walls)

BrownNon FibrousHomogeneous

Dissolved71906362PLM_14

Other 100%

None Detected1238-15

Mastic under Ceramic Tile(Floors/Walls)

BrownNon FibrousHomogeneous

Dissolved71906362PLM_15

Other 100%

Not Analyzed1238-16

Mastic under Ceramic Tile(Floors/Walls)

TEM71906362PLM_16

None Detected1238-17

Black Floor MasticBlackNon FibrousHomogeneous

Dissolved71906362PLM_17

Other 100%

None Detected1238-18

Black Floor MasticBlackNon FibrousHomogeneous

Dissolved71906362PLM_18

Other 100%

Not Analyzed1238-19

Black Floor Mastic

TEM71906362PLM_19

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 3 of 6

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Byron Stroble (48)

P-F-002 r15 1/16/2021

Page 146: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

1238 GlenhavenProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71906362_PLM

Date Reported: 3/8/2019

Date Received: 3/8/2019

Lab Order ID: 71906362

15% Chrysotile

1238-20Sheet Vinyl

BeigeNon FibrousHomogeneous

Teased71906362PLM_20

Cellulose Other 15% 70%

15% Chrysotile

1238-21Sheet Vinyl

BeigeNon FibrousHomogeneous

Teased71906362PLM_21

Cellulose Other 15% 70%

Not Analyzed1238-22

Sheet Vinyl

71906362PLM_22

60% Chrysotile

1238-23Duct Tape

WhiteFibrousHomogeneous

Teased71906362PLM_23

Cellulose Other 20% 20%

60% Chrysotile

1238-24Duct Tape

WhiteFibrousHomogeneous

Teased71906362PLM_24

Cellulose Other 20% 20%

60% Chrysotile

1238-25Duct Tape

BlackNon FibrousHomogeneous

Dissolved71906362PLM_25

Cellulose Other 20% 20%

None Detected1238-26

Wire InsulationBlackNon FibrousHomogeneous

Dissolved71906362PLM_26

Fiber Glass Other 30% 70%

None Detected1238-27

Wire InsulationBlackNon FibrousHomogeneous

Dissolved71906362PLM_27

Fiber Glass Other 30% 70%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 4 of 6

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Byron Stroble (48)

P-F-002 r15 1/16/2021

Page 147: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

1238 GlenhavenProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71906362_PLM

Date Reported: 3/8/2019

Date Received: 3/8/2019

Lab Order ID: 71906362

None Detected1238-28

Wire Insulation

TEM

BlackNon FibrousHomogeneous

Dissolved71906362PLM_28

Fiber Glass Other 30% 70%

None Detected1238-29

Felt Paper under HardwoodFloor

Brown, BlackFibrousHomogeneous

Teased, Dissolved71906362PLM_29

Cellulose Other 60% 40%

None Detected1238-30

Felt Paper under HardwoodFloor

Brown, BlackFibrousHomogeneous

Teased, Dissolved71906362PLM_30

Cellulose Other 60% 40%

Not Analyzed1238-31

Felt Paper under HardwoodFloor

TEM71906362PLM_31

3% Chrysotile

1238-32Exterior Caulk

GrayNon FibrousHomogeneous

Dissolved71906362PLM_32

Other 97%

3% Chrysotile

1238-33Exterior Caulk

GrayNon FibrousHomogeneous

Dissolved71906362PLM_33

Other 97%

Not Analyzed1238-34

Exterior Caulk

71906362PLM_34

None Detected1238-35

Roof ShinglesWhite, BlackNon FibrousHomogeneous

Dissolved71906362PLM_35

Cellulose Other 10% 90%

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 5 of 6

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Byron Stroble (48)

P-F-002 r15 1/16/2021

Page 148: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

Bulk Asbestos AnalysisBy Polarized Light Microscopy

EPA Method: 600/R-93/116 and 40 CFR, Part 763, Subpart E,App.E

1238 GlenhavenProject:

Sample ID

Lab Sample ID

Description

Lab Notes AsbestosFibrous

ComponentsNon-FibrousComponents

Attributes

Treatment

Jeff RiversAttn:Customer: ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Analysis ID: 71906362_PLM

Date Reported: 3/8/2019

Date Received: 3/8/2019

Lab Order ID: 71906362

None Detected1238-36

Roof ShinglesBlack, WhiteNon FibrousHomogeneous

Dissolved71906362PLM_36

Cellulose Other 10% 90%

Not Analyzed1238-37

Roof Shingles

TEM71906362PLM_37

None Detected1238-38

Felt Paper under ShinglesBlackFibrousHomogeneous

Teased, Dissolved71906362PLM_38

Cellulose Other 70% 30%

None Detected1238-39

Felt Paper under ShinglesBlackFibrousHomogeneous

Teased, Dissolved71906362PLM_39

Cellulose Other 70% 30%

Not Analyzed1238-40

Felt Paper under Shingles

TEM71906362PLM_40

5% Chrysotile

1238-41Chimney Flashing

BlackNon FibrousHomogeneous

Dissolved71906362PLM_41

Other 95%

5% Chrysotile

1238-42Chimney Flashing

BlackNon FibrousHomogeneous

Dissolved71906362PLM_42

Other 95%

Not Analyzed1238-43

Chimney Flashing

71906362PLM_43

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/orheterogeneous soil samples be conducted by TEM for confirmation of “None Detected” by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the writtenapproval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. ScientificAnalytical Institute participates in the NVLAP Proficiency Testing program. Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Page 6 of 6

Approved SignatoryAnalyst

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Byron Stroble (48)

P-F-002 r15 1/16/2021

Page 149: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

cnent: Contact: Address: Phone: rl:ix: Ernafl:

,Projecf:

Cllent Notes:

ABS ENVIRONMENTAL JEFF RIVERS 1416 CHAPIN RD.-CHAPIN, SC 803-260-2883 803-345-2823 [email protected]

1238 Glenhaven

72 HR TAT for TEM NOB

P.;p. #. ,;;- .,8 ,[Enter P.O. # Here] Date Submitted: 1] 3/7/2019 0:00

Analysis: IEPA PLM 600 TurriAroundTlme: .· 24 HR TAT

!Sample Number << 1238-01 1238-02 1238-03 1238-04 1238-05 1238-06 1238-07 1238-08 1238-09 1238-10 1238-11 1238-12 1238-13 1238-14 1238-15 1238-16 1238-17 1238-18

Relinquished By

Data 1

[Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here]

I\

To Sr3 a,,,n Jv ajJ1~[~ ~fie~. the bgttom ffx8-mpje Tab.

f:Jote: Data 1 af1;_d Gata 2 are,optional ;& "' fleldsJf,at do 'r]o{:show up on /he.,.officia/

report, h.ow4vel they will be t ncluded in the electronic data returned to you

, ;::-s, &; ;$: £, ' w,, ,~, .!!-, ' 'c'

i-/1 ~0 VJ 6~'L

Sclen'llflc Analytical Institute

to,.facilitate your reintegra_tion of the reoort data.

1,4604 Dundas Drive Greensboro, NC 27.(/107 Rhone: 336.292.3888

Fax: 336.292.3313 Email: [email protected]

Sample Description

Plaster Plaster Plaster Plaster Plaster Joint Compound on Plaster Joint Compound on Plaster Joint Compound on Plaster Joint Compound on Plaster Joint Compound on Plaster Sheetrock behind Plaster Sheetrock behind Plaster Sheetrock behind Plaster Mastic under Ceramic Tile (Floors/Walls) Mastic under Ceramic Tile (Floors/Walls) Mastic under Ceramic Tile (Floors/Walls)

Black Floor Mastic ri Black Floor Mastic

Accepted cf?_

Rejected 0

Data2

[Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here]

TEM NOB If Negative

Received By

~0\ 3 -£ 10'. 36-4\IV\

Page 150: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

1 I °1. 0 '° 2s eo· l_

1238-19 Black Floor Mastic TEM NOB If Negative

1238-20 Sheet Vinyl 1238-21 Sheet Vinyl 1238-22 Sheet Vinyl TEM NOB If Negative

1238-23 Duct Tape 1238-24 Duct Tape 1238-25 Duct Tape 1238-26 Wire Insulation 1238-27 Wire Insulation 1238-28 Wire Insulation 1238-29 Felt Paper under Hardwood Floor

1238-30 Felt Paper under Hardwood Floor 1238-31 Felt Paper under Hardwood Floor TEM NOB If Negative

1238-32 Exterior Caulk 1238-33 Exterior Caulk 1238-34 Exterior Caulk TEM NOB If Negative

1238-35 ' Roof Shingles 1238-36 Roof Shingles 1238-37 Roof Shingles TEM NOB If Negative

1238-38 Felt Paper under Shingles 1238-39 Felt Paper under Shingles

1238-40 Felt Paper under Shingles TEM NOB If Negative

1238-41 Chimney Flashing 1238-42 Chimney Flashing 1238-43 Chimney Flashing TEM NOB If Negative

>>

Relinquished By Received By

Page 151: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

3/9/2019Project: 1238 Glenhaven

Lab Order ID: 71906427

Lab Notes

Description

Lab Sample ID

Sample ID

Semi-QuantitativeChatfield SOP 1988-02 Rev. 1

Asbestos LCL-UCL

(Wt. %)

Bulk Asbestos Analysisby Transmission Electron Microscopy

Date Received:

3/11/2019Date Reported:

3/18/2019

ABS Environmental Inc.1416 Chapin RdChapin, SC 29036

Customer:

Analysis ID: 71906427_TB

Attn: Jeff Rivers

Date Amended:

AcidSol.

Organic

(Wt. %)(Wt. %) (Wt. %)

None Detected-32%

1238-16

71906427TBS_1

Mastic under ceramic tile(floors/walls)

None Detected-82%

1238-19

71906427TBS_2

Black floor mastic

None Detected-61%

1238-28

71906427TBS_9

Wire insulation

None Detected-96%

1238-31

71906427TBS_4

Felt paper under hardwood floor

None Detected-40.%

1238-37

71906427TBS_6

Roof shingles

None Detected-97%

1238-40

71906427TBS_7

Felt paper under shingles

Russell Shelton (6)

Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Approved Signatory

Page 1 of 1tem_2.2.001

Analyst

Disclaimer: This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsementby NVLAP or any other agency of the U.S. government.

T-F-010 r15 1/15/2018

Page 152: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

!Contact: Add,_.: P.hmle: F•: e.--aa. liltHHh

IClanf·~:

Pt-0.'­lldlmltt.ed:

ABS ENVtRONMe-NTAL JEFF RIVERS 1416 CHAPIN RD.-CHAPIN, SC 803·260-2883 803-345~2823 [email protected]

1238 Glenhaven

72 HR TATforTEM NOB

. a. Cdumn "811 for your contact info

To SH an lacampls ClltJlr the bottom Eumplf. 1ttb •

Ii,,...,,,,,. --1111 ~am/~­..,,,,...,.. ..... "<< 'WloW the,,,.,...,,,,,,,,

amid Wltlt Ii ~>",,.,_the,_.,,,,,,,.., Otlly'Enfer yourdi;ta on tlrd first sheet 'Shtletf •

~ ~ L

/IYOlrW87

SdflntHk A.n•lrdai )w;tui., ~

[Enter P. o. # Here] J .Nott,; Dam 1 and'Data 2 are opf/oMI 41104 Dundas Drive 3/7/2019 0:00 ffelt:IBthat·dt>notshowup on tbs dlliGial tlreensboro, NC Z7M1

lfJflO"li hawewr thsy Wiil l»included Phone:~ 33tL2i-2.311aB EPA PLM 600 In.,,,. ~io dst9 retumfld to you FaK: 336.Z9.2.33tS

- ---~ .. - --~- --~-- 24 HR TAT to far;lllb;Je · rein . . tion of th& d.sf:a Email: lab@sai/llb,com

1238-01 1238-02 1238-03 1238-04 1238-05 1238-06 1238-07 1238-08 -1238-09 1238-10 1238-11 1238-12 1238-13 1238-14 1238-15 1238-16 1238-17 1238-18

Relinquished By

[Enter data of your choosing here) [Enter data of your choosing here] [Enter data of your choosing here) [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here) [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here]

Plaster Plaster Plaster Plaster Plaster Joint Compound on Plaster Joint Compound on Plaster Joint Compound on Plaster Joint Compound on Plaster Joint Compound on Plaster Sheetrock behind Plaster Sheetrock behind Plaster Sheetrock behind Plaster Mastic under Ceramic Tile (Floors/Walls) Mastic under Ceramic Tile (Floors/Walls) Mastic under Ceramic Tile (Floors/Walls) Black Floor Mastic d. Black Floor Mastic

Accepted cf?_

Rejected D

[Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here] [Enter data of your choosing here]

TEM NOB If Negative

Received By

~~ "3.'3 lO'-~lV\

Page 153: Asbestos Survey For · 63 Downing St ABS Environmental, Inc. Asbestos Survey ABS Job # 7800.19011

1238-19 1238-20 1238-21 1238-22 1238-23 1238-24 1238-25 1238-26 1238-27 1238-28 1238-29 1238-30 1238-31 1238-32 1238-33 1238-34 1238-35 1238-36 1238-37 1238-38 1238-39 1238-40 1238-41 1238-42 1238-43 >>

Relinquished By

Black Floor Mastic Sheet Vinyl Sheet Vinyl Sheet Vinyl Duct Tape Duct Tape Duct Tape Wire Insulation Wire Insulation Wire Insulation Felt Paper under Hardwood Floor Felt Paper under Hardwood Floor Felt Paper under Hardwood Floor Exterior Caulk Exterior Caulk Exterior Caulk Roof Shingles Roof Shingles Roof Shingles Felt Paper under Shingles Felt Paper under Shingles Felt Paper under Shingles Chimney Flashing Chimney Flashing Chimney Flashing

1)°t0'V :S (ol: 719CTrH97

TEM NOB If Negative

TEM NOB If Negative

TEM NOB If Negative

TEM NOB If Negative

TEM NOB If Negative

TEM NOB If Negative

TEM NOB If Negative

Received By


Recommended