www.aastra.comTel. +41 (32) 655 33 33Fax +41 (32) 655 33 55
I5 - I7.7 HW-SW Compatibility List
To All
Document depl-0023 / CL 669
Version 1.63
State Valid
Date 19. Jan 2009
Author Neuenschwander Kurt
Table of Contents Page Notation
Table of Contents / Notation 2 ok ok
FAQ: I7.5 upgrade and MPC-3 3 (ok) ok, but newer version recomended
x not ok
A150 / A300 (since I7) (x) not recomended
- not existing
MBA A150 / A300 and System Modules 4 (-) recalled / not in field
MBA Interface Cards (+ New TIC-1PRI ) 5 V forbidden / not supported
MBA Wiring Adapters 6 ? not tested
PBX this SW for this component is loaded from PBX
Ascotel IntelliGate 20x5 (since I5) -> In this combinations a newer Sw is loaded from PBX
<- In this combination an older Sw is loaded from PBX
MBS Ascotel IntelliGate 2025 / 2045 (Neris 4 / 8) 7 -1P Prototype HW
MBL Ascotel IntelliGate 2065 (Neris 64) 8
AIMS 9
OIP 10
AMI 11
AVS 12
Cards (for MBS/MBL) 13
AIP Cards (for MBS/MBL) 14
Terminals
Corded Terminals: Office 10 / 25 / 34 / 45 15
Corded Terminals: Aastra 5360 / 5370 / 5380 16
IP Terminal: Office 35IP 17
IP Terminals: Aastra 5360IP / 5370IP / 5380IP 18
Aastra 2380IP + Miscelaneous Terminals 19
DECT Terminals (Office130/135) 20
DECT Terminals (Office155/160) 21
DECT Systembases (SB4, SB4+, SB8) 22
Page 2(1) Page 2(2)
FAQ: Updateset 7.5-7.7 and MPC-3
01) How do I upgrade from 7.1 to 7.5-7.7 on Ascotel IntelliGate 2025/2045/2065 ? 07) What is "fast boot" and "slow boot" for Ascotel IntelliGate 2065 (MBL)?
Get the Updateset 7.5-7.7 (20350410), and use the included upgrade manual (syd-245) "Fast Boot" is needed to support MPC-3 with 300 MHz.
- "Slow Boot" contains: normal MBS-Boot + 133 MHz MBL-Boot for MPC-1
02) Why does the Updateset 7.5-7.7 contain SW 7.16+ ? - "Fast Boot" contains: normal MBS Boot + 300 MHz MBL-Boot for MPC-3
7.16+ runs on Flash-03-1. It allows the "onsite" HW-upgrade for 20x5-Satellites at any time, Notes:
without loosing the connection to the 7.16 - Master. It can only be changed by reloading the entire Boot-SW, which normally is not needed.
Later the whole AIN can be upgraded to a SW 7.5-7.7 from one "remote" station. - New MBL 7.5 (or higher) are delivered with MPC-3 and Flashcard with "fast Boot"
- Sparepart MPC-3 is delivered with Flashcard with "fast Boot"
03) I upgrade an 2065 from 7.16 to 7.71. Shall I take the UDS 7.5-7.7 or the MPC-3 ?
MPC-3 can be used, but it is more expensive and the MPC-3 is not mandatory for 7.5-7.7 08) Where can I check, if my MPC-3 is supported with "fast boot" ?
MPC-3 is delivered with SW 7.67 (not like 7.16+ on UDS 7.5-7.7) Port 1056 Status Monitor: 0 StatusLine - 1 Board Basic HW + SW Info: CPU-clock 300
AIMS CM_1_1_2: Hardware Cards, MPC HW version: 3-F
04) Why does SSU (smart SW upgrade) sometimes propose a newer SW than a new delivery?
SW upgrade in fabrication (and stocks) is slow and expensive. 09) Is MPC-1 and MPC-2 protected from overheating by fast boot ?
SSU supplies the best SW at the time when the PBX is installed at the client site. Of course. MBL doesn't startup. C P U - E R R O R comes 3 times on the 7-Seg.display
This can happen, if you have moved a Flash-03-1 (with fast boot) from an MPC-3
05) Why does MPC-1B not work with 7.5 or higher ?It wasn't possible and it will be rare. MPC-1B were delivered until March 03 with SW 5.0x - 5.30 10) Where can I get Boot-SW and how can I load it ?
Repair returns MPC-1C (with invoice for the MPC-card) or you can order the sparepart MPC-3. In normal use it is not needed, and we don't recommend it, because it is not powerfail safe.
Fabrication and repair ensure the right Boot-SW on the right Flashcard.
06) Why do some MBS-1 not work with 7.5 or higher ?
This happens, if you took an 128 MB SDRAMcard (20'350'412) from a 7.5 (or higher) PBX 11) Does "flashcopy" still work with Flash-03-1(A) from I7.5 ?Use the 128 MB SDRAMcard (20'350'579) from the Updateset 7.5-7.7 (20350410) Flashcopy is for internal use only. It still works, but with an "unfriendly" exception:
(also in MPC-3 the SDRAM (20'350'412) is delivered) On MBL-1 it does not work. (... depending on the flash-component-supplier)
12) What is the difference between Office 70IP-b and Office 70IP ?
Office70IP-b works as a Office35IP on PBX 5.5 -7.1, has a special "Short User Manual"
with less functions and it is shown as Office35IP in AIMS.
Office 70IP-b can be reconfigured in AIMS 7.5 Office35IP -> Office70IP and then works
as a normal Office 70IP on PBX 7.5, but will need a licence.
13) Why does my IP-phone not work ?From PBX 7.5 and higher every IP phone needs a licence.
Page 3(1) Page 3(2)
MBA A150 A300 + System Modules I5-I6-I7-compatibility-2009-01-19.xls
Mainboard A150/A300 System Modules
LAN Switch Modul
EXP Ascotel A150/A300 7.65 -1 Beta a) -1Spain Neris 2 IP / básica 7.62 -1 Beta a) -1
Motherboard (MBA) -1 Beta a) -1 0.07 7.00 -1 j) -1A -1P -1 k) -1A -1
I7 MBA 7.02 (pbx7042f1) ok ok (ok) ok ok ok (-) (-) ok ok
MBA 7.10 (pbx7054b1) (ok) b) (ok) b) (ok) ok ok ok (-) (-) ok ok
MBA 7.11 (pbx7056b1) ok ok (ok) ok ok ok (-) (-) ok ok
I71 MR1 MBA 7.16 (pbx7058d1) ok ok (ok) ok ok ok (-) (-) ok ok
MBA 7.51 (pbx7531c1) (ok) c) (ok) c) (ok) ok ok ok (-) (-) ok ok
MBA 7.52 (pbx7533a1) ok ok (ok) ok ok ok (-) (-) ok ok
MBA 7.53 (pbx7536h1) ok ok (ok) ok ok ok (-) (-) ok ok
MBA 7.60 (pbx7631f1) (ok) (ok) (ok) ok ok ok (-) (-) ok ok
MBA 7.61/7.63 (pbx7631i1 / j1) ok ok (ok) ok ok ok (-) (-) ok ok
Spain R2R MBA 7.62/7.64 (pbx7631s1 / t1) ok ok (ok) ok ok ok (-) (-) ok ok
I76 MR1 MBA 7.65 (pbx7642g1) ok ok (ok) ok ok ok (-) (-) ok ok
Spain R2R MBA 7.66, n642 (pbx7642s1 / n1) ok ok (ok) ok ok ok (-) (-) ok ok
I76 MR2 MBA 7.67 / 7.68 (pbx7648c1 / g1) ok d) ok d) (ok) ok ok ok (-) (-) ok ok
I77 MBA 7.71 (pbx7751e1) ok d) ok d) (ok) ok ok ok (-) (-) ok ok
a) Beta-version: 9th digit of article.nr. = "0" j) SM-DSP01-1 of prod.date 08.2006 was recalled (wrong assembled) b) 7.10 only released in France only for A300/A150 k) SM-DSP02-1 recalled (A300 can't start up) -> Sept 06: DSP02-1A c) It is recommended to load newer Sw than 7.51, using SSUd) I76 MR2 supports CLIP on ab-subscriber-ports
DSP on MBA: DSP-Modules: SM-LAN8:The DSP Chip on MBA supports basic functions and VM 20 Min 2 ports 3 DSP modules can be stacked over each other. 2 SM-LAN8 can be used ... and 2 VoIP (free) or 4 DECT or VM 160 Min 2/4 Port (with licence) Each DSP Chip on the DSP-Modules can be configured for The SM-LAN8 is plugged in 2 WA-sockets
4 VoIP (with licence) or 8 DECT or VM 160 Min 2/4 Port (with licence) The SM-LAN8 can be combined with AD2 Cards
PBX-Appl.SW
Boot A300/A150
HW A300/A150
ok = ok(ok) = ok, but newer version recomended(x) = not recommended x = not ok - = not existing(-) = recalled / not in field
I71
I75
I76
In fabrication SM-LAN8
DSP-Modules
SM-DSP01(1 DSP Chip)
SM-DSP02(2 DSP Chips)
Note: With Boot 7.00 on PBX 7.6, 7.7 the coredump must not be used. A Boot version 7.7 will be released for these rare cases.
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 4
MBA Interface Cards I5-I6-I7-compatibility-2009-01-19.xls
ok = ok(ok) = use newer version(x) = not recommended x = not ok
Trunk Cards Subscriber Cards
EAAB2 a) TIC-1PRI EAD4V c) OAPM ODAB d) NOTST
PBX-Appl.SW-1 -1P -1 -1P -1 -1 -2 -1P -1 -1P -1 -1 -1 -1A -2 -1 -2 -1 -2 -2 -1 -1 -1
MBA 7.02 ok ok ok ok ok X ok ok ok ok ok X ok ok ok ok ok ok ok ok X ok XMBA 7.1x ok ok ok ok ok X ok ok ok ok ok X ok ok ok ok ok ok ok ok X ok X
MBA 7.5x, 7.6x, n642 ok ok ok ok ok X ok ok ok ok ok X ok ok ok ok ok ok ok ok X ok XMBA 7.67, 7.68 ok ok ok ok ok X ok ok ok ok ok X ok e) ok e) ok e) ok ok ok ok ok X ok X
MBA 7.71 ok ok ok ok ok X ok ok ok ok ok ok ok e) ok e) ok e) ok ok ok ok ok X ok X
New cards for A150/A300 (Wiring Adapter included)a) on EAAB2 the 2 trunk lines are on port 3,4. details see MBA Wiring Adapters TIC-2AB with WA-2W (2ab-trunk)b) ESST HW -1: remote maintenance not ok (few exist in CH, I, E) TIC-4AB with WA-2W (4ab-trunk)c) EAD4C, EAD4V not possible in Slot 4. (too long) TIC-2TS with WA-TS0 (TT,ST), or order WA-TS1 (SS)d) Use ODAB in Slot 2 of A150, or Slot 4 of A300 for full functionality. TIC-4TS with WA-TS0 (TTTT,STTT), or order WA-TS1 (SSTT,SSST)
e) since I76 MR2 CLIP on ab-subscriber-ports supported
A150 supports 2 Slots for Cards Needed Cards from Ascotel 200 (Wiring Adapter included)
A300 supports 4 Slots for Cards ETAB4 is needed for a/b subscribers. (WA-2W is already included)
EADP4 is recommended for AD2. (WA-2W is already included)
Each Card needs a Wiring Adapter in the assigned WA-socket. ODAB needed for door interface. (WA-TS1 already included)
Details see MBA Wiring Adapters
Old Cards from Ascotel 200 (Wiring Adapter not included)
EAAB2 ... for new orders TIC-2/4AB shall be usedESST ... for new orders, TIC-2/4TS shall be usedEAD4C works as AD2 only. It is not needed. Courtesy already included on MBA. EAD4V works as AD2 only. It is not needed. VM already included on MBA.OAPM not needed on A150/A300NOTST not needed on A150/A300.
Digital subscribercard Special cards
EADP4 EAD4C c)
Analog trunkcards
Analog subscribercards
ESST b)
ISDN trunkcards
TIC-2TS ETAB4TIC-4ABTIC-2AB TIC-4TS
NEW with I77: PRA on A300 with the new TIC-1PRI !
(A300 and isyLink can replace 2025/2045)
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 5
MBA Wiring Adapters I5-I6-I7-compatibility-2009-01-19.xls
Used with Card WA Connector side Port Configuration Port x.1 Port x.2 Port x.3 Port x.4TIC-4TS TTTT TTTT T T T TTIC-4TS STTT STTT S T T TTIC-2TS TTTT TT T TTIC-2TS STTT ST S T
ESST a) STTT ST S TTIC-4TS a) SSTT SSTT S S T TTIC-4TS a) SSST SSST S S S TTIC-2TS a) SSTT SS S STIC-2TS a) SSST SS S SESST a) SSTT SS S SESST a) SSST SS S S
ODAB SSTT IO & Door/ab IO 1&2 IO 3&4 ab/TFEETAB4 2 Wire 4 * ab ab ab ab abEADP4 2 Wire 4 * AD2 AD2 AD2 AD2 AD2
EAD4C a) 2 Wire 4 * AD2 AD2 AD2 AD2 AD2EAD4V a) 2 Wire 4 * AD2 AD2 AD2 AD2 AD2EAAB2 a) 2 Wire 2 * ab trunk - - ab ab
TIC-2AB 2 Wire 2 * ab trunk ab ab - -TIC-4AB 2 Wire 4 * ab trunk ab ab ab ab
TIC-1PRI WA-1PRI T2 - - - T2
Switch-socket 4 * AD2 & LAN c) AD2 & LAN AD2 & LAN AD2 & LAN AD2 & LAN
no Card inserted - 4 * LAN LAN LAN LAN LANEADP4, EAD4C, EAD4V - 4 * AD2 & LAN c) AD2 & LAN AD2 & LAN AD2 & LAN AD2 & LAN
no Card inserted - 4 * LAN LAN LAN LAN LANEADP4, EAD4C, EAD4V - 4 * AD2 & LAN c) AD2 & LAN AD2 & LAN AD2 & LAN AD2 & LAN
a) Wiring adapter has to be ordered separately (not delivered together with the card)b) System Module SM-LAN8 is plugged in 2 WA-sockets -> It supports 8 LAN-interfaces
c) the RJ45 must be split: - PIN's 1,2,3,6 for the LAN - PIN's 4,5 for AD2
Assigned to AD2-ports on Motherboard
Wiring Adapter
WA-TS0
WA-TS1
WA-2W
WA-1PRI
SM-LAN8 b)
Left Leg
Right Leg
WA-Socket
WA-Socket
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 6
MBS 2025 2045 I5-I6-I7-compatibility-2009-01-19.xls
Neris4/8, Spain 7.66 -1 -2 -3(A) -5A -62025/2045 Export 7.67 a) -1 -2,-3 -4 -5(A) -6
MBS -1 -2 -3(A) -3(A) -3AFlash-card & RAM-card 1) 1) 1) 4b) 5b) 5.00 5.10 5.20 5.40 5.50 6.10 6.20 6.50 6.52 6.53 h) 7.50 i)
5.0x ok X X X X ok ok ok ok ok (X) (X) X X X X 5.0x5.1x- 5.3x ok X X X X X ok ok ok ok (X) (X) X X X X 5.1x- 5.3x5.5x- 6.0x ok ok X X X X ok ok ok ok (X) (X) X X X X 5.5x- 6.0x
6.1x ok ok X X X X ok ok ok ok ok ok X X X X 6.1x 6.2x ok ok ok X X X ok ok ok ok ok ok X X X X 6.2x
6.5x - 7.16 ok 4) ok 4) ok 4) ok X X X X X X X X (ok) ok ok X 6.5x - 7.167.11+, 7.16+, 7.5x, 7.6x, n642 ok 5),n) ok 5) ok 5) ok 5) ok X X X X X X X X X X ok 7.11+, 7.16+, 7.5x, 7.6x, n642
7.67, 7.68, 7.71 b) ok 5),n) ok 5) ok 5) ok 5) ok b) X X X X X X X X X X ok 7.67, 7.68, 7.71 b)
a) please use SSU, to get newer Sw than delivered from fabrication 5.00 5.10 5.20 5.40 5.50 6.10 6.20 6.50 6.52 6.53 h) 7.50 i) Boot / HW
b) the CLIP on ab-subcriber ports is not supported on MBS. X ok ok ok ok ok ok ok 4) ok 4) ok 4) ok 5) MBS-1 with 1)
(It needs new HW MBS-4, which is not yet planned) X X X ok ok ok ok ok 4) ok 4) ok 4) ok 5) MBS-2 with 1)
X X X X X X ok ok 4) ok 4) ok 4) ok 5) MBS-3(A) with 1)
HW-versions of MBS (Motherboard Small) X X X X X X X ok ok ok ok 5) MBS-3(A) with 4b)MBS-1: no Rackversion X X X X X X X X X X ok MBS-3A with 5b)MBS-2: new ISAC + new QSLAC + TI483: system clock exactMBS-3 new SLIC + Flash socket (1 SIM-80 + 1 SO-DIMM144) 5.00 5.10 5.20 5.40 5.50 6.10 6.20 6.50 6.52 6.53 h) 7.50 i) Boot / Flashcard g)
+ Courtesy Flash changed to LV400 needs PBX 6.2* - ok ok ok ok ok ok - - - - Flashcard-01-2
MBS-3A: Including ISDN-Filter on T-port - - - - ok - ok - - - - Flashcard-01-2A- - - - - - - ok ok ok - Flashcard-02-2
n) MBS-1 incompatible with "some" 128 MB DRAM (20'350'412) - - - - - - - ok ok ok - Flashcard-02-2A
If you took an 128 MB SDRAMcard (20'350'412) from a new 7.5 PBX - - - - - - - - - - ok Flashcard-03-1Use the upgradeset 7.5 with the 128 MB SDRAMcard (20'350'579) - - - - - - - - - - ok Flashcard-03-1A
Flash-card & RAM-card Boot SWf) the Boot SW >= 6.50 is the same for 2025/2045 and 2065
1) Included on I5, I6 MBS g) Compatibility between Boot-SW and Flashcard is ensured in fabrication Flash-01-2 (incl. DL400, MBS-Boot 5.*, 6.*) / RAM 32 MB h) Boot 6.53 supports more Flashtypes (jan 2007)or Flash-01-2A (incl. LV400, MBS-Boot 5.50, 6.20) / RAM 32 MB i) There is slow and fast Boot 7.5, but the difference is only for MBL 2065.
4) Upgrade set I6.5 -I7.1 (contains MBS and MBL SW until 1st Sw update) -1: PBX 6.51, Flash-02-2 (Boot 6.5*) / RAM 64 MB Licence Chip: -1A: PBX 6.52, Flash-02-2 (Boot 6.52, 6.53) / RAM 64 MB (Generations: I5 country -> I6 international -> I65 internat. with new coding) -1A, aug 07: PBX 6.52, Flash-02-2A (Boot 6.53) / RAM 64 MB
- EIM is automatically converted during a SW upgrade or downgrade ... Spain Upgradeset I6.6: - EIM can be moved to another PBX of same or newer generation -1: PBX 6.65, Flash-02-2A (Boot 6.53) / RAM 64 MB - EIM can NOT be moved to a PBX of older licence generation
- EIM can NOT be moved between MBS and MBL4b) Included on I6.5 - I7.1 MBS the same as 4), but only MBS SW
Please always make an AIMS full backup, even if a SW-upgrade5) Upgrade set I7.5-I7.7 (contains MBS and MBL SW until 1st Sw update) is possible without Firststart or Flash/RAM upgrade: -1: PBX 7.11+, Flash-03-1 (Boot 7.50) / RAM 128 MB -1, july 07: PBX 7.16+, Flash-03-1 (Boot 7.50) / RAM 128 MB (see TI 1218) - OK: from "older" I5 PBX SW to "newer" I5 PBX SW -1A, aug 07:PBX 7.16+, Flash-03-1A (Boot 7.50) / RAM 128 MB - OK: for MBS from I5 (>=5.30) to I6 (>= 6.20)
- OK: from I6.5 to I6.6 to I7.15b) Included on I7.5/I7.6 MBS - OK: from I7.5, I7.6 to I7.7 the same as 5), but only MBS SW
ok = ok(x) = not recommended x = not ok - = not existing(-) = recalled
PBX-Appl.SW2025/2045
Boot 2025/2045 Boot 20x5 f)
HW 2025/2045
In fabrication
Note: With Boot 7.5 on PBX 7.6, 7.7 the coredump (d-switch for support cases) must not be used. A Boot version 7.7 will be released for these rare cases.
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 7
MBL 2065 I5-I6-I7-compatibility-2009-01-19.xls
Neris64, Spain 7.66 -1C -2 -3(A) -5A -62065, Export 7.67 a) -1C -2 -3 -5(A) -6
MBL -1C -2 -2(A) -2(A) -2A -2AFlash-card & RAM-card 2) 2) 3b) 4b) 5a) 5b) -1/1A -1B -1C -2 -3 5.10 5.20 5.30 5.50 6.01 6.10 6.20 6.50 6.52 6.53 h) 7.50 slow 7.50 fast
5.0x -5.20 ok X X X X X (-) ok X X X ok ok ok ok (X) (X) (X) X X X X X 5.0x -5.205.30 / AMI A100 ok ok X X X X (-) ok X X X ok ok ok ok (X) (X) (X) X X X X X 5.30 / AMI A100
5.5x / 5.6x / AMI A101 ok ok X X X X (-) ok ok ok X ok ok ok ok (X) (X) (X) X X X X X 5.5x / 5.6x / AMI A1016.0*-6.1x ok 3) ok 3) (ok) a) X X X (-) ok ok ok X X X X X ok ok ok X X X X X 6.0*-6.1x
6.2x ok 3) ok 3) ok X X X (-) ok ok ok X X X X X ok ok ok X X X X X 6.2x6.5x - 7.11 ok 4) ok 4) ok 4) ok ok X (-) ok ok ok X X X X X X X X (ok) ok ok X X 6.5x - 7.11
7.11+, 7.16+, 7.5 - 7.71, n642 ok 5) ok 5) ok 5) ok ok ok (-) X m) ok ok ok X X X X X X X X X X ok ok 7.11+, 7.16+, 7.5 - 7.71, n642
a) please use SSU, to get newer Sw than delivered from fabrication 5.10 5.20 5.30 5.50 6.01 6.10 6.20 6.50 6.52 6.53 h) 7.50 slow 7.50 fast Boot / MPCok ok ok ok ok ok ok ok ok ok ok X k) MPC-1x
HW-versions of MBL (Motherboard Large) ok ok ok ok ok ok ok ok ok ok ok X k) MPC-2MBL-1,1A,1B are the same (except plugged MPC-8260 version) X X X X X X X X X X slow i) fast i) MPC-3MBL-1C: TI 479: resets if more than 9 SCcards + hand-sol. "5V"MBL-2: "plug for extra-powersupply" ATPS + TI 479: 5V powerMBL-2A: New SIM Card connector 5.10 5.20 5.30 5.50 6.01 6.10 6.20 6.50 6.52 6.53 h) 7.50 slow 7.50 fast Boot / HW + Courtesy Flash changed to LV400 needs PBX 6.2* ok ok ok ok ok 3) ok 3) ok 3) ok 4) ok 4) ok 4) ok 5) ok 5c) MBL-1C with 2)
a) MBL-2A needs PBX-SW 6.2* X X ok ok ok 3) ok 3) ok 3) ok 4) ok 4) ok 4) ok 5) ok 5c) MBL-2 with 2)
X X X X ok ok ok ok 4) ok 4) ok 4) ok 5) ok 5c) MBL-2 with 3)
HW-versions of MPC-8260 X X X X X X X ok ok ok ok 5), 5a) ok 5c) MBL-2 with 4b)-1 recalled 6.11.01 (TI 463: Ports on SC-04AB/ SC-08AB blocked) X X X X X X X X X X X ok MBL-2A with 5b)-1A recalled 21.11.01(TI 466: Seldom, remote access via ISDN not possible)-1B solves TI 463 & TI 466 5.10 5.20 5.30 5.50 6.01 6.10 6.20 6.50 6.52 6.53 h) 7.50 slow 7.50 fast Boot / Flashcard g)-1C solves TI 483: The system clock on HW-1B is not exact ok ok ok ok - - - - - - - - Flashcard-01-2-2 new Sparepart CPU-8255 for performance (see TI 1146) X X X ok - - - - - - - - Flashcard-01-2A
- - - - ok ok ok - - - - - Flashcard-02-1m) MPC-1B is incompatible with 7.5 - - - - X X ok - - - - - Flashcard-02-1AMPC-1B was delivered until March 03 with SW 5.30 or smaller - - - - - - - ok ok ok - - Flashcard-02-2-> If an MPC-1B with plugged I7.5 Flash & RAM is sent to repair, it will be - - - - - - - ok ok ok - - Flashcard-02-2A replaced with MPC-1C, with an invoice for the MPC-Card. - - - - - - - - - - ok ok Flashcard-03-1
- - - - - - - - - - ok ok Flashcard-03-1A
Flash-card & RAM-card (included in PBX or in Upgradesets) Boot SW
2) Included on I5 MBL 4b) Included on I6.5 - I7.1 MBL f) the Boot SW >= 6.50 is the same for 2025/2045 and 2065 Flash-01-2 (incl. DL400, MBL-Boot 5.*) / RAM 32 MB the same as 4), but only MBL-SW g) Compatibility between Boot-SW and Flashcard is ensured in fabricationor Flash-01-2A (incl. LV400, MBL-Boot 5.50) / RAM 32 MB h) Boot 6.53 supports more Flashtypes for Spain production with PBX 6.65
5) Upgrade set I7.5 - I7.7 i) There is slow and fast Boot 7.5 (see also FAQ, page 2)3) Upgrade Set I6 for MBL (out of production, use directly 4 or 5) (contains MBS and MBL SW until 1st Sw update) k) Protected from overheating: PBX not starting. Flash-02-1 (incl. DL400, MBL-Boot 6.*) / RAM 64 MB -1: PBX 7.11+, Flash-03-1 (Boot 7.50 slow) / RAM 128 MBor Flash-02-1A (incl. LV400, MBL-Boot 6.20) / RAM 64 MB -1, july 07: PBX 7.16+, Flash-03-1 (Boot 7.50 slow) / RAM 128 MB (see TI 1218)
-1A, aug 07:PBX 7.16+, Flash-03-1A (Boot 7.50 slow) / RAM 128 MB Licence Chip: 3b) same as 3) but already included on I6 MBL - EIM is automatically converted during a SW upgrade or downgrade 5a) Spain I76 MBL contains MPC-1 and slow Boot 7.50 - EIM can be moved to another PBX of same or newer generation4) Upgrade set I6.5 -I7.1 '- PBX 7.66, Flash-03-1A (Boot 7.50 slow) / RAM 128 MB - EIM can NOT be moved to a PBX of older licence generation (contains MBS and MBL SW until 1st Sw update) - EIM can NOT be moved between MBS and MBL -1: PBX 6.51, Flash-02-2 (Boot 6.5*) / RAM 64 MB 5b) Included on I7.5 - I7.7 Export MBL -1A: PBX 6.52, Flash-02-2 (Boot 6.52, 6.53) / RAM 64 MB - Export I75-I77 from fabrication is always delivered with MPC-3 -> 5c) -1A, aug 07: PBX 6.52, Flash-02-2A (Boot 6.53) / RAM 64 MB Please always make an AIMS full backup, even if a SW-upgrade
5c) Sparepart MPC-3 is possible without Firststart or Flash/RAM upgrade: ... Spain Upgradeset I6.6: -3: MPC-3 and MBL 7.65, Flash-03-1 (Boot 7.50 fast) / RAM 128 MB - OK: from "older" I5 PBX SW to "newer" I5 PBX SW -1: PBX 6.65, Flash-02-2A (Boot 6.53) / RAM 64 MB -3 aug 07: MPC-3 and MBL 7.51, Flash-03-1A (Boot 7.50 fast) / RAM 128 MB - OK: from I6.5 to I6.6 to I7.1
- OK: from I7.5, I7.6 to I7.7
Boot 20x5 f)HW MPC-8260
ok = ok(x) = not recommended x = not ok - = not existing(-) = recalled
PBX-Appl.SW2065
HW 2065
Boot 2065In fabrication
Note: With Boot 7.5 on PBX 7.6,7.7 the coredump (d-switch for support cases) must not be used. A Boot version 7.7 will be released for these rare cases.
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 8
AIMS I5-I6-I7-compatibility-2009-01-19.xls
PBX-Appl.SW I77One number
PBX-Appl.SW
5.10.015.10.02,5.10.03 5.20.03 5.30.03 5.50.* 6.00.16 6.10.06 6.20.02 6.52.01 6.53.00 6.60.21 6.63.01
Spain k)6.63.05 7.00.13 7.10.05 7.50.11 7.50.12 m) 7.60.10/13 7.61.02/04a 7.62.03 7.70.12
PBX 5.0x (ok) (ok) (ok) (ok) ok (ok) (ok) ok (ok) (ok) (ok) ok ok (ok) ok ? ? X X X X PBX 5.0xPBX 5.1x X (ok) (ok) (ok) ok (ok) (ok) ok (ok) (ok) (ok) ok ok (ok) ok ? ? X X X X PBX 5.1xPBX 5.20 X (X) (ok) (ok) ok (ok) (ok) ok (ok) (ok) (ok) ok ok (ok) ok ? ? X X X X PBX 5.20PBX 5.30 X X X (ok) ok (ok) (ok) ok (ok) (ok) (ok) ok ok (ok) ok ? ? X X X X PBX 5.30
PBX 5.5x / 5.6x X X X X ok (ok) (ok) ok (ok) (ok) (ok) ok ok (ok) ok ? ? X X X X PBX 5.5x / 5.6xPBX 6.00 X X X X X (ok) (ok) ok (ok) (ok) (ok) ok ok (ok) ok ? ? X X X X PBX 6.00PBX 6.1* X X X X X X (ok) ok (ok) (ok) (ok) ok ok (ok) ok ? ? X X X X PBX 6.1*
PBX 6.20-6.23 X X X X X X X ok (ok) (ok) (ok) ok ok (ok) ok ? ? X X X X PBX 6.20-6.23PBX 6.25-6.27 X X X X X X X X i) (ok) (ok) (ok) ok ok (ok) ok ? ? X X X X PBX 6.25-6.27PBX 6.51-6-53 X X X X X X X X (ok) (ok) (ok) ok ok (ok) ok ? ? X X X X PBX 6.51-6-53PBX 6.54-6.55 X X X X X X X X X (ok) (ok) ok ok (ok) ok ? ? X X X X PBX 6.54-6.55PBX 6.60, 6.62 X X X X X X X X X X (ok) ok h) ok (ok) ok (X) ok X X X X PBX 6.60, 6.62
PBX 6.63, 6.64, 6.66, 6.67 X X X X X X X X X X X ok h) ok (ok) ok (X) ok X X X X PBX 6.63, 6.64, 6.66, 6.67SPAIN PBX 6.65 k) X X X X X X X X X X X X ok X X X X X X, k2) X, k2) X, k2) SPAIN PBX 6.65 k)
PBX 7.02 X X X X X X X X X X X X X (ok) ok (X) ok SQL, n) SQL, n) SQL, n) SQL, n) PBX 7.02PBX 7.10, 7.11, 7.16 X X X X X X X X X X X X X X ok (X) ok SQL, n) SQL, n) SQL, n) SQL, n) PBX 7.10, 7.11, 7.16PBX 7.51, 7.52, 7.53 X X X X X X X X X X X X X X X (X) ok SQL, n) SQL, n) SQL, n) SQL, n) PBX 7.51, 7.52, 7.53PBX 7.60, 7.61, 7.63 X X X X X X X X X X X X X X X (X) X ok ok ok ok PBX 7.60, 7.61, 7.63
SPAIN PBX 7.62 / 7.64 X X X X X X X X X X X X X X X (X) X ok ok ok ok SPAIN PBX 7.62 / 7.64(I76 MR1) PBX 7.65 X X X X X X X X X X X X X X X (X) X X ok ok ok (I76 MR1) PBX 7.65
SPAIN PBX 7.66, n642 X X X X X X X X X X X X X X X (X) X X ok ok ok SPAIN PBX 7.66, n642(I76 MR2) PBX 7.67, 7.68 X X X X X X X X X X X X X X X (X) X X X ok ok (I76 MR2) PBX 7.67, 7.68
PBX 7.71 X X X X X X X X X X X X X X X (X) X X X ok ok z) PBX 7.71
a) Backups of PBX < 5.50 with AIMS < 5.50 can be loaded to PBX 5.50 with AIMS 5.50 m) for SSU please use AIMS 7.50.12 or higher (recommended: AIMS 7.61.02)b) Backups of PBX 5.50 with AIMS 5.50 can be loaded to PBX < 5.50 with AIMS < 5.50. ...and don't install an older AIMS with SSU on the same PC later (see RI 1214)
i) Some 6.2 PBX can not be configured with any 6.2 AIMS n) can only be configured with AIMS 7.6 with SQL-DB. There are 2 possibilities:- convert complete DB: AIMS shell: Tools - "Import Paradox DB" (warning: overwrites SQL-DB)
h) PBX 6.6x and AIMS UM 6.6.1.0 and newer: support IP35 on Satellites in Offline mode - a backup of PBX 7.x in AIMS 7.10.05, can be restored in AIMS 7.61.02
k) Spanish PBX 6.65 needs AIMS 6.63.05 (late MDT change, RMS 33904 Long SIP Id) z) many changes because of the "One Number" (new term: subscriber -> user)AIMS 6.63.05 is compatible to older PBX (eg. Spain PBX 5.50, 5.61, 6.21) + new Card TIC-PRI for MBA, new DSP-Combination-builds, ....
k2) A backup of PBX 6.65 in AIMS 6.63.05, can be restored in AIMS 7.61.02 or higher, but is at the same time converted to PBX 7.6. Spain uses AIMS 7.61.04a
For Export countries it is recommended to use: - AIMS 7.10.05 for PBX 5.0 - 7.1 - AIMS 7.70.12 (with SSU) for PBX 7.5- 7.7
ok = ok(ok) = compatible, but newer version recomended(x) = not recomended x = not ok - = not existing? = not tested
AIMS
Generation I5 Generation I6 I6.5AIN
I7A300
I75Aamadeus IP
I76Aamadeus IP + AD2
Windows Vista:- AIMS 7.6 and higher runs on Windows Vista, backward compatible till PBX 7.0x- AIMS 7.50.12 and older can run on Windows Vista in "NT-mode": * Switch off "User Account Control" in the "Security Center" (you need admin rights) * Restart Windows and Install AIMS 7.50.12 or older
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 9
OIP I5-I6-I7-compatibility-2009-01-19.xls
Office 1560IP -> X X X X X X X (0.7)
X(0.13) 1.0 1.1 2.0.30.0 2.0.30.0 2.1.31.0 2.1.31.0 2.2.36.1 2.2.38.0 2.2.38.0 2.2.38.0 2.2.38.0 2.3.46.0 2.2.38.0 2.3.49.0 2.3.50.0 <- Office 1560IP
Office 1600IP -> 6.1.0.0 6.1.1.3 6.1.1.3 6.2.0.2 6.2.0.2 6.2.0.2 6.5.1.7 6.5.2.1 6.5.2.2 6.5.2.2 6.6.0.9 6.6.0.10 6.6.0.11 6.6.0.11 7.0.0.4 7.0.0.7 7.5.0.0 7.5.0.2 7.5.0.2 7.6.0.5 7.6.2.2 7.6.2.2 7.6.2.2 <- Office 1600IP
OIP-TSP -> 6.1.0.0 6.1.2 6.1.2 6.2.0.1 6.2.0.2 6.2.0.4 6.5.0.9 6.5.2.1 6.5.2.6 6.5.3.0 6.6.4.0 6.6.4.0 6.6.9.0 6.6.9.0 7.0.4.0 7.1.1.0 7.1.1.0 7.1.1.0 7.1.2.0 7.6.12.0 7.6.18.0 7.6.19.0 7.7.2.0 <- OIP-TSP
Office Suite -> X X X X X X X X X X X X X X X X X X X 1.0.0.0 1.7.2.0 1.7.4.0 2.1.2.0 <- Office Suite
Office eDial -> X X X X X X X X X X 1.0.1.0 1.0.2.0 1.0.4.0 1.0.4.0 1.0.4.0 1.0.5.0 1.0.6.0 1.0.7.0 1.0.8.0 1.0.8.0 1.0.8.0 1.0.8.0 1.1.0.0 <- Office eDial
OIP PBX
6.1.0.0 6.1.1.3 6.1.1.7 6.2.0.4 6.2.0.6b 6.2.1.1 6.5.0.11 6.5.2.2 6.5.2.6 6.5.3.36.5.3.4 6.6.0.14 6.6.0.16 6.6.1.7 6.6.2.0 6) 7.0.0.7 7.1.0.8 7.5.0.0 7.5.0.1 7.5.0.2 7.6.0.17 7.6.2.3 7.6.3.2 7.7.1.0 OIP
PBX6.00 X X X X X X X X X X X X X X X X X X X X X X X 6.006.10 ok X X X X X X X X X X X X X X X X X X X X X X 6.106.11 ok ok (ok) 1) (ok) 1) (ok) 1) (ok) 1) (ok) 1) (ok) 1) (ok) 1) (ok) 1) (ok) 1) (ok) 1) (ok) 1) (ok) 1) (ok) 1) (ok) 1) (ok) 1) (ok) 1) (ok) 1) (ok) 1) (ok) 1) (ok) 1) not tested 6.11
6.20-6.23 X X (ok) 1) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) not tested 6.20-6.236.25-6.27 X X X ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) ok 2) not tested 6.25-6.27
6.51 X X X X X X ok 3) ok 3) ok 3) ok 3) ok 3) ok 3) ok 3) ok 3) ok 3) ok 3) ok 3) ok 3) ok 3) ok 3) ok 3) ok 3) not tested 6.516.52 - 6.55 X X X X X X ok 3) ok 3) ok 4) ok 4) ok 4) ok 4) ok 4) ok 4) ok 4) ok 4) ok 4) ok 4) ok 4) ok 4) ok 4) ok 4) not tested 6.52 - 6.556.60,6.62 X X X X X X X X X X ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) not tested 6.60,6.62
6.63, 6.64, 6.66, 6.67 X X X X X X X X X X ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) not tested 6.63, 6.64, 6.66, 6.67Spain 6.65 X X X X X X X X X X (ok) (ok) (ok) ok 5), 6) (ok) 5) (ok) 5) (ok) 5) (ok) 5) (ok) 5) (ok) 5) (ok) 5) (ok) 5) not tested 6.65
7.02 X X X X X X X X X X X X X X ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) not tested 7.027.10, 7.11, 7.16 X X X X X X X X X X X X X X X ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) not tested 7.10, 7.11, 7.167.51, 7.52, 7.53 X X X X X X X X X X X X X X X X ok 5) ok 5) ok 5) ok 5) ok 5) ok 5) not tested 7.51, 7.52, 7.537.60, 7.61, 7.63 X X X X X X X X X X X X X X X X X X X ok ok ok ok 7.60, 7.61, 7.63
Spain 7.62, 7.64, 7.66, n642 X X X X X X X X X X X X X X X X X X X ok a) ok a) ok a) ok a) Spain 7.62, 7.64, 7.66, n6427.65, 7.67, 7.68 X X X X X X X X X X X X X X X X X X X ok ok ok ok 7.65, 7.67, 7.68
7.71 X X X X X X X X X X X X X X X X X X X X X X ok 7.71
1) ACD Applications do not work correctly in this combination a) Translations for Spain missing in OIP 7.6 2) Improved ACD Applications & new DAK features (eg. Busy signalling to Call Centers) -> Spain wants to deliver them 2009 with OIP 7.7 and Incl. Spanish Language, OEM Splashscreens (needs Saleschannel detection) 3) New I6.5 features / AIN4) Including Office1560 Serie !5) New: Office 1560 with IP, Office 1600IP with AD26) Spanish strings only in old generation OIP 6.6.2.0
3rd Party CTI (without OIP): 1st Party CTI:- PBX-SW 5.1*-5.3* needs Ascotel TAPI Driver TSP Version 5.1.0 - AIF-TSP 1.0.0.0 and Office eDial 1.0.2.0 (released together with PBX 6.60)- PBX-SW 5.5*/5.6* needs Ascotel TAPI Driver TSP Version 5.5.0.1 or higher (newest version 5.5.0.6) - AIF-TSP 1.0.1.0 and Office eDial 1.0.4.0 (released together with PBX 6.63)- PBX-SW 6.00 needs Ascotel TAPI Driver TSP Version 6.0.0.0 or higher (newest version 6.0.0.2) - AIF-TSP 1.0.2.0 and Office eDial 1.0.8.0 (compatible with Vista, released together with PBX 7.60)
- AIF-TSP 1.0.3.0 and Office eDial 1.0.8.0 (compatible with Vista, released together with PBX 7.65)- AIF-TSP 1.2.0.0 and Office eDial 1.1.0.0 (compatible with Vista, released together with PBX 7.71)
Windows Vista:
- Windows Vista is supported with OIP I7.6 and newer- Generally Applications run on Vista since Project 7.6
OpenCom-PBX:- OIP 7.6.2.3 and higher supports OpenCom-PBX
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 10
AMI I5-I6-I7-compatibility-2009-01-19.xls
Ascotel Mobility Interface
-1C -2 -3 till -6MBL-1C MBL-2 MBL-2A
MBL 5.0x - 5.6x only PBXMBL A100 c) only AMI b) X ok ok ok X (-) ok X X X ok ok ok okMBL A101 c) only AMI b) X ok ok ok X (-) ok ok ok X ok ok ok ok
MBL 6.0x -7.7x AMI and PBX ok d) ok d)
a) AMI only supported with Ascotel 2065b) SW A100, A101 supports only AMI (don't use the MBL for other PBX extensions or functions)c) SW A100, A101 are based on MBL SW 5.3* with same compatibility, except A101 supports more MPC-versionsd) AMI is supported on newer HW version with SW version 6.0* - 7.5* (see MBL compatibility)
MPC-8260
-1/1A -1B -1C -3-2MBL-Appl.SW
AIMSISDN
-01PRAISDN
-02PRA
-1 -1A -1 -1A
Ascotel IntelliGate 2065
5.20.03
see AIMS page
see MBL pagesee AIMS page
Supported Functionality
(AMI,PBX)5.30.03
see Cards page
see Cards pagesee MBL page
see MBL page see MBL page
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 11
AVS I5-I6-I7-compatibility-2009-01-19.xls
5.05 5.12 5.20 5.50 5.52 6.20 6.65 6.69 6.70
-1 ok ok ok ok ok ok ok ok ok
-1A x x x x x x ok ok ok orange: Combinations in the field
Boot 5.2 ok x x x x x x x xBoot 5.4 ok ok ok ok ok ok ok ok ok
PBX 5.00 ? ? x x x x x x xPBX 5.10 ok ? x x x x x x xPBX 5.11 ok ok (x) (x) (x) (x) (x) (x) (x)PBX 5.20 ok ok (x) (x) (x) (x) (x) (x) (x)
PBX 5.30-5.6x x x ok ok ok ok ok 1) ok 1) ok 1)
PBX 6.0x-6.55 x x ok ok ok ok ok 1) ok 1) ok 1) 1) Old functions, old MMI, but new I6.6-limits6.60 - 6.64 x x ok 2) ok 2) ok 2) ok 2) ok 3) ok 3) ok 3) 2) Old functions old MMI, old limits
6.65 x x ok 2) ok 2) ok 2) ok 2) ok 3) ok 3) ok 3) 3) New functions, new MMI, new I6.6-limits6.66, 6.67 x x ok 2) ok 2) ok 2) ok 2) ok 3) ok 3) ok 3)
7.02, 7.11, 7.16 x x ok 2) ok 2) ok 2) ok 2) ok 3) ok 3) ok 3)
7.5x, 7.6x, n642, 7.71 x x ok 2) ok 2) ok 2) ok 2) ok 3) ok 3) ok 3)
5.05 ok ok x x x x x x x5.07 ok ok ok x x x x x x5.08 ok ok ok ok ok x x x x5.10 ok ok ok ok ok ok x x x
6.60.12, 6.60.13 a) ok ok ok ok ok ok ok ok x a) VMM 6.60.13 incl. since AIMS 6.606.60.16, 6.60.17 b) ok ok ok ok ok ok ok ok ok b) VMM 6.60.17 incl. since AIMS 7.10 and VMM 6.60.16 in AIMS 6.63.05 for Spain
VOX-Files
5.05 5.12 5.20 5.50 5.52 6.20 6.65 6.69 6.70 5.05 5.07 5.08 5.10 6.60.12 6.60.13 6.60.16 6.60.17
I5 I5 All g) ok ok ok ok ok ok X X X ok ok ok ok ok ok ok ok I5 All g)I6.6 All h) x x x x x x ok ok ok x x x x ok ok ok ok I6.6 All h)
I6.6 Catalan i) x x x x x x x x ok x x x x x x ok ok I6.6 Catalan i)
g) ....501.Vox : original Vox-File with 3 languages
....502.Vox: Msg004 "Silence" instead of "please wait" ( BE, DK, CH, PT, SE & Msg007 changed for NL)
h) ...660.Vox: original Vox-File for generation I6.6 with 3 languages
...662.Vox: Msg004 & Msg102 "Silence" instead of "please wait" (BE, DK, CH, PT, SE, & Msg007 changed for NL)
i) ES_esenca660.vox : Catalan language for Spain needs new AVS version 6.70 ... And VMM 6.60.16 or higher
VM Generation I5 VM Generation I6.6
AVS SW
VM Generation I6.6
Vox-Files / Rules
Voice Mail Manager (VMM)
Vox-Files, Rules
I5I6
.6
VM Generation I5 VM Generation I6.6
Voice Mail Manager (VMM) AVS SW
I6.6
ok = ok(x) = not recommended x = not ok - = not existing? = net tested
PBX-SW
VM Generation I5I5
VM-02P,VM-04P
AVS Boot
I6.6
How to use I6.6 Catalan-Vox-File for I5.50 in Spain:- Get AIMS 6.63.05 according Footnote b)- Use VMM 6.60.16 to load VM 6.70 to the AVS-Card- Use VM 6.60.16 to load the I6.6 Catalan Vox-File=> now it works according footnote 1)
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 12
Cards I5-I6-I7-compatibility-2009-01-19.xls
-08ST -32AD2 DSP-04 DSPX-02
PBX-Appl.SW HW HW HW HW
-1 -1Aa)
-1Bb)
-1
- 2-2A-2Bc)
- 2-2A-2Bc)
-1 -1A -1 -1A -1 -1Ad)
-2-2Ae)
-3 g) -1 -1Ad)
-2-2Ae)
-3 g) -1 -2f)
-3 g) -1 -1A -1 -1A -1 -1A -1 -1A -1 -1 -1A -1 -1A -1 -1 -1 -1Ag)
PBX-Appl.SW
PBX 5.0x ok x x ok x x ok ok ok ok ok x x x ok x x x x x x ok ok ok ok ok ok ok ok x ok x ok x x x ok x PBX 5.0x
PBX 5.1x-5.3x ok ok x ok x x ok ok ok ok ok x x x ok x x x x x x ok ok ok ok ok ok ok ok x ok x ok x x x ok x PBX 5.1x-5.3x
PBX 5.5x /5.6x ok ok ok ok ok ok ok ok ok ok ok ok x x ok ok x x x x x ok ok ok ok ok ok ok ok x ok ok ok ok x x ok ok PBX 5.5x /5.6x
PBX 6.0x, 6.1x ok ok ok ok ok ok ok ok ok ok ok ok x x ok ok x x ok x x ok ok ok ok ok ok ok ok ok ok ok ok ok ok x ok ok PBX 6.0x, 6.1x
PBX 6.2x - 6.6x ok ok ok ok ok ok ok ok ok ok ok ok ok x ok ok ok x ok ok x ok ok ok ok ok ok ok ok ok ok ok ok ok ok x ok ok PBX 6.2x - 6.6x
PBX 7.02, 7.11, 7.16 ok ok ok ok ok ok ok ok ok ok ok ok ok x ok ok ok x ok ok x ok ok ok ok ok ok ok ok ok ok ok ok ok ok x ok ok PBX 7.02, 7.11, 7.16
PBX 7.51, 7.52, 7.53 ok ok ok ok ok ok ok ok ok ok ok ok ok x ok ok ok x ok ok x ok ok ok ok ok ok ok ok ok ok ok ok ok ok x ok ok PBX 7.51, 7.52, 7.53
PBX 7.61 - 7.64 ok ok ok ok ok ok ok ok ok ok ok ok ok x ok ok ok x ok ok x ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok PBX 7.61 - 7.64
PBX 7.65 - 7.66, n642 ok ok ok ok ok ok ok ok ok ok ok ok ok ok g) ok ok ok ok g) ok ok ok g) ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok PBX 7.65 - 7.66, n642
PBX 7.67, 7.68, 7.71 ok ok ok ok ok ok ok ok ok ok ok ok ok ok h) ok ok ok ok h) ok ok ok h) ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok ok PBX 7.67, 7.68, 7.71
a) TC-04AB-1A: removed components for dialtone detection d) SC-04/08AB-1A: new QSLAC & old SLIC (NFI5-014) g) OI-2DOOR-1A: new QSLAC (NFI5-014) dialtone detection ist done by SW (SW 5.10 and higher) e) SC-04/08AB-2: old QSLAC & new SLIC (less old SLIC available, than old QSLAC)b) TC-04AB-1B: new QSLAC (NFI5-014) SC-04/08AB-2A: new QSLAC & new SLIC (final solution)c) ISDN-04/08ST-2,-2A: new ISAC (NFI5-014) f) SC-16AB-2: new QSLAC & new SLIC (final solution) ISDN-04/08ST-2B -> ISDN-Filter on T-port g) -3 new SLIC supported since I76 MR1 (7.65)
h) new SLIC supports CLIP for ab-subscr. since I76 MR2 (7.67)
HW HW HW HWHW
Special Cards
DSP-Cards Option Interface
DSP-01 DSP-02 OI-2DOOR
ok = ok(x) = not recommended x = not ok - = not existing
Analog subscribercards
Digital subscribercard
ISDN-04ST ISDN-01PRA ISDN-02PRA
ISDN PRAcards
SC-16ABSC-04AB SC-08AB
Trunk cards
SC-16AD2
Subscriber Cards
SC-24AD2
Analog trunkcards
ISDN trunkcards
SC-04AD2 SC-08AD2
HW
TC-04AB
HW HWHW HW HW HWHWHW
DSPX-02
- more VoIP channels per DSP or FAX over IP T.38- also supports DECT, VM, GSM (same as the other DSP cards).
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 13
AIP Cards I5-I6-I7-compatibility-2009-01-19.xls
AIP 6350SW
PBX-Appl.SW- 1 - 2 - 2A 2.02 5.50 5.52 - 1 - 1 e) - 2 - 2A 5.50 6.50.1 6.52.1 6.52.2 6.54.0 6.60.5 6.63.0 7.0.1 7.1.1 7.6.0 7.7.1
PBX 5.0x ok ok ok ok ok ok ok - - - x x x x x x x x x x xPBX 5.10 ok ok ok ok ok ok ok - - - x x x x x x x x x x xPBX 5.11 ok ok ok ok ok ok ok - - - x x x x x x x x x x xPBX 5.20 ok ok ok ok ok ok ok - - - x x x x x x x x x x xPBX 5.30 ok ok ok ok ok ok ok - - - x x x x x x x x x x x5.5x/5.6x ok ok ok ok ok ok ok x ok ok ok x x x x x x x x x xPBX 6.0* ok ok ok ok ok ok ok X ok ok ok x x x x x x x x x xPBX 6.1* ok ok ok ok ok ok ok X ok ok ok x x x x x x x x x xPBX 6.2* ok ok ok ok ok ok ok X ok ok ok x x x x x x x x x xPBX 6.51 ok ok ok ok ok ok ok X ok ok A) -> PBX <- B) <- B) <- B) <- <- <- <- <- <-
6.52,6.53 ok ok ok ok ok ok ok X ok ok A) -> B) -> PBX <- B) <- B) <- <- <- <- <- <-
PBX b567 ok ok ok ok ok ok ok X ok ok A) -> B) -> B) -> PBX <- B) <- <- <- <- <- <-
6.54,6.55 ok ok ok ok ok ok ok X ok ok A) -> B) -> B) -> B) -> PBX <- <- <- <- <- <-
6.60, 6.62, b655 ok ok ok ok ok ok ok X ok ok D) X -> -> -> -> PBX <- <- <- <- <-
6.63-6.67 ok ok ok ok ok ok ok X ok ok D) X -> -> -> -> -> PBX <- <- <- <-
7.02 ok ok ok ok ok ok ok X ok ok D) X -> -> -> -> -> -> PBX <- <- <-
7.11, 7.16 ok ok ok ok ok ok ok X ok ok D) X -> -> -> -> -> -> -> PBX <- <-
7.51, 7.52, 7.53 ok ok ok ok ok ok ok X ok ok D) X -> -> -> -> -> -> -> PBX <- <-
7.61-7.66 ok ok ok ok ok ok ok X ok ok D) X -> -> -> -> -> -> -> -> PBX <-
7.67, 7.68, n642, 7.71 ok ok ok ok ok ok ok X ok ok D) X -> -> -> -> -> -> -> -> -> PBX
e) The codec G.729 is not fully supported in this combinartion. (TI 519) PBX This AIP SW included in this PBX-SW-package->, <- The compatible AIP SW is loaded, if either ...
Don't use DRS 4/8-1 and DRS4/8-2* on the same card !!! - the SW-package is loaded with the Upload Manager- the PBX is restarted
A) AIP6350 becomes AIP6500 by SW update !B) in I6.5 the AIP6500 SW can also be loaded with the
Reset-button on the AIP6500C) AIP6400 can be changed to AIP6500 (TI 999)D) AIP6350 must be updated by hand or on I6.5 (TI 999)
AIP 6350 / AIP 6500
AIP Cards
AIP 6400 C)IP-IPIHW
SWDRS-04/08
HW
AIP 6400 / 6350 / 6500 (IP-Card: IPI-100BT)
DRS-04/08HW
AIP 6500SW
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 14
Corded Terminals I5-I6-I7-compatibility-2009-01-19.xls
Office10,20,30,40 AKB
HW SW
PBX-Appl.SW-1* -1 -1A -1A -1B
-1C -2 d) 1.00(1.10) 1.30 1.60 -1 -1A -1B -2 d) 1.00 1.10 1.20 1.00
1.10 1.20 1.22 1.23 1.00 1.40 1.00
PBX I4 / I4net ok a) X X ok ok ok X X ok b) X X X X X X X X X X X X c) ok b) XPBX 5.0* -5.3* ok ok ok ok ok ok ok X ok ok ok ok ok (X) (X) ok (X) ok ok ok ok ok okPBX 5.5* / 5.6* ok ok ok ok ok ok ok X ok ok ok ok ok (X) (X) ok (X) ok ok ok ok ok okPBX 6.0* - 6.2* ok ok ok ok ok ok ok X ok ok ok ok ok (X) (X) ok (X) ok ok ok ok ok ok
6.5*, 6.6* ok ok ok ok ok ok ok X ok ok ok ok ok (X) (X) ok (X) ok ok ok ok ok ok7.02 - 7.16 ok ok ok ok ok ok ok X ok ok ok ok ok (X) (X) ok (X) ok ok ok ok ok ok7.51 - 7.53 ok ok ok ok ok ok ok X ok ok ok ok ok (X) (X) ok (X) ok ok ok ok ok ok
7.6x, n642, 7.71 ok ok ok ok ok ok ok X ok ok ok ok ok (X) (X) ok (X) ok ok ok ok ok ok
a) Office10 works with >= 4.65. Office 20, 30,40 works since 4.0* Office 35 SW:1.00 in fabric., until July 04 (Spain-Label, 1.10)
b) Office 35 1.60 and EKP 1.40 work on I4 / I4net 1.30 recalled (RMS 30275, 22476: Office35 resets)... except in Italy Freemarket, where it only works since PBX 4.75 (ARTE-Bit) 1.60 in fabric. since July 04 (also for Spain)
c) Don't use EKP 1.00 on I4 /I4net. It causes PBX Resets ! ... Since Aug 2004 only EKP 1.40 is produced and delivered Office 45 Boot SW
1.00 in fabric. from Mai 01 - Oct 01d) New HW -2 because "end of life" of a IC-Component (TI 1216) 1.10 recalled (TI 464) Can't load Office45 Appl-SW
1.20: in fabric. since Nov.01
Office 45 Appl SW (loaded from PBX)1.00 loaded from PBX 5.00 (not recommended)1.10 loaded from PBX 5.1* (not recommended)1.20 loaded from PBX 5.20 (1.20 in fabric. loaded from Nov. 2001)1.22 loaded from PBX 5.501.23 loaded from PBX 6.10
ok = ok(X) = not recommended X = not ok - = not existingV = forbidden
HW SWBoot-SW Appl-SWHWHW SW
Office 25 Office 35 Office 45 / 45pro EKP
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 15
Aastra 5360, 5370 , 5380 I5-I6-I7-compatibility-2009-01-19.xls
Office 60 Aastra 5360
HW -1 -2
Terminal-Boot - - 2.6.14.1 2.6.14.1 2.6.14.1 j) 2.12.4.2 2.12.4.2 k) 2.12.4.2 2.12.4.2 0.6.1 0.8.0 z) 0.8.0 0.8.0 0.8.0 z) 0.8.0 0.8.0
Terminal -Sw. - - 2.6.15.1 2.6.18.1 2.6.18.2 j) 2.6.19.1 2.6.18.2k) 2.50.10.1 l) 2.50.14.3 0.6.0 0.8.2 z) 0.8.3 0.8.7 0.8.2 z) 0.8.3 0.8.7
PBX 5.0* -5.3* X X X X X X X X X X X X X X X X
PBX 5.5* - 7.1* X X X X X X X X X X X X X X X X
7.5x X X X X X X X X X ok ok ok ok X X X
7.60 ok ok -> PBX <- <- <- <- <- (->) (->) (PBX) ok -> PBX ok
7.61- 7.64 ok ok -> -> PBX <- <- <- <- (->) (->) (PBX) ok -> PBX ok
7.65, -7.68, n642 ok ok -> -> -> PBX <- <- <- (->) (->) (PBX) ok -> PBX ok
7.71 ok ok -> -> -> -> -> -> PBX (->) (->) (->) (PBX) -> -> PBX
j) state in fabrication Office70/80 k) state in fabrication Aastra 5370/5380 (PBX), (->) = M530-SW loaded from PBX, only if power supply on AD2 resp. on IP Phonel) production for AMT
z) state in fabrication
Aastra M535 (Office DKBM-1)
-2
Office 70 / 80 Aastra 5370 / 5380
-1 -2
ok = ok(X) = not recommended X = not ok - = not existing
PBX = AD2-Terminal-Sw loaded from this PBX-> , <- = other Sw loaded (see PBX)(PBX), (->) = KBM-SW loaded, only if power supply on AD2
PB
X-A
ppl-S
W
Aastra M530 (Office KBM-1/-1A)
-2
Office Terminals -> Aastra Terminals:- There is no effect on the compatibility, it's only a renaming.- The Hw-version -2 is only an improvement with no effect on the compatibility.- From Feb 2009 only Aastra Terminals are delivered. (except Spain)
Aastra Terminals on Nexspan:- Aastra Terminals are prepared and in test to work on Nexspan PBX
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 16
Office 35IP I5-I6-I7-compatibility-2009-01-19.xls
Boot SW Boot SW SW SW SW SW SW SW SW SW
-2 -2A h) 1.0.0 5.5.0(1.0.7) 2.0.0 6.2.0
(1.3.3)6.5.0
(1.4.5)6.5.2
(1.5.0)1.5.1
(1.5.1)6.6.0
(1.5.4)1.5.7
(1.5.7)1.6.0
(1.6.0)1.6.1
(1.6.1)1.6.2
(1.6.2)PBX 5.0x -5.3x X X X X X X X X X X X XPBX 5.5x / 5.6x ok ok ok ok ok ok ok ok ok ok ok okPBX 6.0x -6.2x ok ok ok ok ok ok ok ok ok ok ok ok
PBX 6.5* ok ok ok -> f) -> f) PBX <- <- <- <- <- <-PBX b567 ok ok ok -> f) -> f) -> f) PBX <- <- <- <- <-
PBX 6.54,6.55 ok ok ok -> f) -> f) -> f) -> f) PBX <- <- <- <-6.60, 6.62 ok ok ok -> f) -> f) -> f) -> f) -> f) PBX <- <- <-
b655 ok ok ok -> f) -> f) -> f) -> f) -> f) -> f) PBX <- <-6.63-6.67, 7.02 ok ok ok -> f) -> f) -> f) -> f) -> f) -> f) -> f) PBX <-7.1x-7.6x, 7.71 ok ok ok -> f) -> f) -> f) -> f) -> f) -> f) -> f) -> f) PBX
d) PBX I6.5 needs Office35IP (Boot 2.0.0 and SW >= 1.4.5) Office70IP-b can replace Office 35IPe) How to upgrade Office 35IP Boot 2.0.0 -> TI 953 see next pagef) PBX >= 6.5 loads newer SW into Office 35IP, only if Boot is 2.0.0- IP35 1.6.0 and higher supports IP35 assigned to Satellite in Offline Mode- IP35 HW -2A supports Power over Ethernet "PoE 802.3af", details see TI 971
.
X d), e)
ok X d), e) X d), e)
ok = ok(X) = not recommended X = not ok - = not existingPBX = this Sw is loaded from PBX? = not tested
X d), e) X d), e)
X
Office 35IP
HW
X d), e) X d), e)
ok
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 17
Aastra 5360IP, 5370IP , 5380IP I5-I6-I7-compatibility-2009-01-19.xls
IP Phone licence
Bootloader (fix)
Terminal-Boot 1.0.4 1.0.6 1.1.0 1.1.4 1.1.6 1.1.10 g) 1.1.1 1.1.3 1.1.7 1.2.9 1.2.10 1.2.10 1.2.10 1.3.8 1.3.9 k) 1.6.12
Terminal -SW 1.0.2 1.0.3 1.1.0 1.1.5 1.1.7 1.1.10 g) 2.2.4 2.2.6 2.2.10 2.6.18 2.6.24 2.6.26 2.6.30 2.10.20 2.10.24 k) 2.50.20 d) d)
5.0x -5.3x X X X X X X X X X X X X X X X X X X
5.5x - 7.1x 35IP 35IP 35IP 35IP 35IP 35IP X X X X X X X X X X X X
7.51 35IP h) 35IP h) 35IP h) 35IP h) 35IP h) 35IP h) (X) <- <- <- <- <- <- <- <- <- ok X
7.52 35IP h) 35IP h) 35IP h) 35IP h) 35IP h) 35IP h) -> PBX <- <- <- <- <- <- <- <- ok X
7.53 35IP h) 35IP h) 35IP h) 35IP h) 35IP h) 35IP h) -> -> PBX <- <- <- <- <- <- <- ok X
7.60 -7.64 35IP h) 35IP h) 35IP h) 35IP h) 35IP h) 35IP h) -> -> -> PBX <- <- <- <- <- <- ok ok
7.65, 7.66 35IP h) 35IP h) 35IP h) 35IP h) 35IP h) 35IP h) -> -> -> -> PBX <- <- <- <- <- ok ok
Spain n642 35IP h) 35IP h) 35IP h) 35IP h) 35IP h) 35IP h) -> -> -> -> -> -> PBX <- <- <- ok ok
7.67, 7.68 35IP h) 35IP h) 35IP h) 35IP h) 35IP h) 35IP h) -> -> -> -> -> PBX <- <- <- <- ok ok
7.71 35IP h) 35IP h) 35IP h) 35IP h) 35IP h) 35IP h) -> -> -> -> -> -> -> -> -> PBX ok ok
h) Aastra 5370IP/Office70IP with Sw 1.x.x (70IP-b) can be registered in AIMS as : g) Office 60IP, 70IP, 80IP (HW -1/1A, Sw 1.x.x) were delivered until Nov 2008. d) Details see page 16 - Office 35IP. Then it needs no license. (KBM/DKBM is not supported) Office70IP could be used directly as 70IP-b - h) - Aastra 5370IP/Office 70IP it receives new SW (from PBX) and requires a license Office60IP/ 80IP always directly received newer SW
i) Downgrade of Aastra 5370 IP (HW-2) to SW 1.x.x (70IP-b) is possible, k) Since Nov 2008 only Aastra 5360IP, 5370IP, 5380IP are delivered. Tool see RI 1159 or "IP Uploadmanager" available on DL server They contain more RAM (Hw -2) and SW 2.x.x and new Boot-loader 1.0.6
HW-version (details)-1 Export was used only for the deliveries 70IP-b-1A (Export) was used with the new deliveries 70IP-1 (Spain-OEM) is the same as -1A Export-1A (Spain-OEM) additional OEM-requirement-2 (Export) more RAM + Aastra-terminal names
d) d)
-2 -2
ok = ok(X) = not recommended X = not ok - = not existing
PB
X-A
ppl-S
W
PBX = "Terminal-SW" AND "Terminal-Boot" loaded from this PBX-> , <- = other SW loaded (see PBX)(->), (PBX) = KBM-SW loaded, only if power supply on IP-Phone
HW-2 (more RAM)
License needed
Aastra M530 Aastra M535 Aastra 5360IP / 5370IP/ 5380IP (HW -2)
Office 60IP / Office 70IP / Office 80IP (HW-1/-1A)
as Office 35IP no license needed
1.0.5 / 1.0.6
-1/-1A also ok here-1/-1A
"Office 70IP-b"= Aastra 5370IP/Office 70IP with SW 1.x.x
works as Office 35IP
5370IP -2 also works here i) -2 also works here
-1/-1A
Each Aastra 5360IP, 5370IP 5380IP (Office 60IP / 70IP / 80IP) needs a licence except when used as Office 35IP with SW 1.x.x
Aastra Terminals on Nexspan:- Aastra IP terminals with SW 2.10.20 or higher work on Nexspan PBX - Aastra 5380IP exists also with Azerty Keyboard
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 18
Aastra 2380IP + Misc. Terminals I5-I6-I7-compatibility-2009-01-19.xls
ok = ok(X) = not recommended X = not ok - = not eXistingV = forbidden
Exp, -2A Exp, -2B Es, -2A
1.0.0.0 1.509.0.0 1.1* 1.2* a) <1.32 b) 1.32 c) 1.33 1.34 < 2.4 2.4 2.5 2.6 2.5 5.00 SP1 SP2 6.10PBX 5.0* -5.6* X X (X) ok V (X) ok ok X ok (ok), e) (ok) (ok) (ok) ok
PBX 6.0* X X (X) ok V (X) ok ok X ok (ok), e) (X) (X) (X) okPBX 6.1* - 6.55 X X (X) ok d) V (X) ok d) ok d) X ok (ok), e) (X) (X) (X) ok
6.60, 6.67 X X (X) ok d) V (X) ok d) ok d) X ok (ok), e) (X) (X) (X) ok g)7.02 - 7.16 X X (X) ok d) V (X) ok d) ok d) X ok (ok), e) (X) (X) (X) ok g)7.5x -7.64 X X (X) ok d) V (X) ok d) ok d) X ok (ok), e) X X X X
(I76 MR1) 7.65, 7.66, n642 (ok) y) X z) (X) ok d) V (X) ok d) ok d) X ok (ok), e) X X X X(I76 MR2) 7.67,7.68 ok X z) (X) ok d) V (X) ok d) ok d) X ok (ok), e) X X X X
7.71 X z) ok (X) ok d) V (X) ok d) ok d) X ok (ok), e) X X X X
z) WARNING: Aastra 2380IP is not forward or backward compatible. a) Office100: SW 1.20 or higher is recommended to avoid old problems And it must be loaded manually. b) Office150: SW <1.32 called back from the field, with no exception !!
c) Office150: SW 1.32 is only allowed in Spain !y) Aastra 2380IP in I76 MR1 is ok, but newer generation recommended because of restrictions and bugs: - no Trial license - expansion-modul key-label allows only 14 digits (not 20) - not possible to dial canonical number format (+43 ...)
. Pocket Adapter:e) ECO 20214 (march 06) - Export -2A / SW 2.5 is not ok on AD2 cables longer than 400m - Spain -2A / SW 2.5 has no problem (it is the same as Export -2B / 2.6)
PC Operator, Office1550:f) Follow-up product see Office1560 in OIPg) Dataloader" for Office 1550 configuration, see DL-serverh) Office1550 is no more supported since 7.5
ok
Office 100
SW
Office 150
SW
okok
Pocket-Adapter
HW-2A
PRISA-1
SoftphoneAastra 2380IP
SW
ok
ok
SW
PC OperatorOffice1550 f)
ok
ok
SW
okok
PRISA-2
d) For Office100/150 on PBX 6.1-6.5 set "Compatibility Mode"= "Old Mode", see AIMS CM 1-3-1-1 "Cordless-DECT- Sys.param." In "Old Mode" only 6 lines used on SB8, Default setting is "New Mode"
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 19
DECT-130-135 I5-I6-I7-compatibility-2009-01-19.xls
Air SW Download: Compatibility:"PBX" this DECT-SW is incl. in the PBX-SW Everything is compatible with few restrictions:"ok" this DECT-SW is unchanged (when registered on PBX) "130" Office135 works only as 130 (and keeps the SW, see c) )"->" newer DECT-SW is loaded (when registered on PBX, System "A")"<-" older DECT-SW is loaded (when registered on PBX, System "A") Compatibility with I4/I4net, see CL 992
"SW Category": protection from older SW"Lab.version": Internal version, twice Longklick 5
SW Category 0 0 0 0 0 0 0 1 1 2 2 3 4 4 5 6 6 6 7 8 8 8 8
Lab.version
00.53.00
00.57.00
00.58.00
00.61.00
00.62.00
00.68.00
00.70.00
60.81.00
60.89.00
60.95.00
61.01.00
61.08.00
61.09.00 /ES 61.10.00
61.16.00
61.20.00
61.23.00
61.25.00
61.26.00
61.28.00
61.32.00
61.34.00
61.37.00
61.38.00
DECT PBX
2.00 2.10 2.11 2.12 2.13 2.14 2.15 2.21 2.30 2.40 3.00 3.01 3.02 /ES3.00 3.03 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 61.38.00
5.0x ok ok ok ok ok ok ok ok ok ok ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 1305.10 a) -> PBX <- <- <- <- <- ok ok ok ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130
5.11 -> PBX <- <- <- <- <- ok ok ok ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 1305.20 -> -> PBX <- <- <- <- ok ok ok ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 1305.30 -> -> -> PBX <- <- <- ok ok ok ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 1305.50 -> -> -> -> -> -> PBX ok ok ok ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 1305.52 -> -> -> -> -> -> PBX ok ok ok ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 1305.55 -> -> -> -> -> -> -> PBX <- ok ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 1305.61 -> -> -> -> -> -> -> -> -> PBX <-, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 1305.63 -> -> -> -> -> -> -> -> -> -> ->, 130 PBX, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 1305.64 -> -> -> -> -> -> -> -> -> -> ->, 130 ->, 130 ->, 130 ->, 130 PBX, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 1306.00 -> -> -> -> -> -> -> -> PBX ok ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130 ok, 130
6.10 b) -> -> -> -> -> -> -> -> -> -> PBX ok ok ok ok ok ok ok ok ok ok ok ok6.11 -> -> -> -> -> -> -> -> -> -> -> PBX ok ok ok ok ok ok ok ok ok ok ok6.20 -> -> -> -> -> -> -> -> -> -> -> -> -> PBX ok ok ok ok ok ok ok ok ok6.21 -> -> -> -> -> -> -> -> -> -> -> -> -> -> PBX ok ok ok ok ok ok ok ok6.23 -> -> -> -> -> -> -> -> -> -> -> -> -> -> PBX ok ok ok ok ok ok ok ok
6.25-6,27 -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> PBX ok ok ok ok6.51 -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> PBX <- ok ok ok ok ok
6.52, 6.53 -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> PBX ok ok ok ok ok6.54,6.55 -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> PBX ok ok ok ok6.60, 6.62 -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> PBX <- <- <-6.63 - 6.67 -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> PBX <- <-7.02, 7.10 -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> PBX <- <-
7.11, 7.16, 7.5x -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> PBX <-7.6x, n642, 7.71 -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> -> PBX
a) Office130 Air SW download, since PBX 5.10b) Office135 Air SW download, since PBX 6.10
Office 130 a) Office130, Office 135c)
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 20
DECT-155-160 I5-I6-I7-compatibility-2009-01-19.xls
Air SW Download:"PBX" this DECT-SW is incl. in the PBX-SW"ok" this DECT-SW is unchanged (when registered on PBX)"->" newer DECT-SW is loaded (when registered on PBX, System "A")"<-" older DECT-SW is loaded (when registered on PBX, System "A")
"SW Category": protection from older SW"Lab.version": Internal version, twice Longklick 5
HW-version -2SW Category 0 0 0 1 2 2 2 3 4 4 4 5 1 2 4 5 6 7 8
Lab.version
00.35.00
00.37.00
00.39.00
00.41.00
00.46.00
00.48.00
00.53.00
00.56.00
00.59.00
00.61.00
00.62.00
00.66.00
41.21.00
41.24.00
41.31.00
41.33.00
41.37.00
41.41.00
41.43.00
DECT PBX
1.00 1.01 1.02 1.03 1.10 1.11 1.12 1.13 1.15 1.16 1.17 1.18 1.01 1.03 z) 1.10 1.12 1.13 1.14 1.16
5.0x ok ok ok ok ok ok ok ok ok ok ok ok as 130 as 130 as 130 as 130 as 130 as 130 as 1305.50 a) -5.55 -> -> PBX a) ok ok ok ok ok ok ok ok ok as 130 as 130 as 130 as 130 as 130 as 130 as 130
5.61 -> -> -> -> PBX ok ok ok ok ok ok ok as 130 as 130 as 130 as 130 as 130 as 130 as 1305.63 -> -> -> -> -> PBX ok ok ok ok ok ok as 130 as 130 as 130 as 130 as 130 as 130 as 1305.64 -> -> -> -> -> -> -> PBX ok ok ok ok as 130 as 130 as 130 as 130 as 130 as 130 as 1306.00 -> -> PBX ok ok ok ok ok ok ok ok ok as 130 as 130 as 130 as 130 as 130 as 130 as 1306.1x -> -> -> -> -> PBX <- ok ok ok ok ok as 130 as 130 as 130 as 130 as 130 as 130 as 1306.20 -> -> -> -> -> -> PBX ok ok ok ok ok as 130 as 130 as 130 as 130 as 130 as 130 as 1306.21 -> -> -> -> -> -> -> PBX ok ok ok ok as 130 as 130 as 130 as 130 as 130 as 130 as 1306.23 -> -> -> -> -> -> -> -> PBX <- <- ok as 130 as 130 as 130 as 130 as 130 as 130 as 130
6.25-6.27 -> -> -> -> -> -> -> -> -> -> PBX ok as 130 as 130 as 130 as 130 as 130 as 130 as 1306.51 -> -> -> -> -> -> -> -> -> PBX <- ok as 130 as 130 as 130 as 130 as 130 as 130 as 130
6.52-6.55 -> -> -> -> -> -> -> -> -> -> PBX ok as 130 as 130 as 130 as 130 as 130 as 130 as 1306.60 -6.67 -> -> -> -> -> -> -> -> -> -> -> PBX PBX y) ok ok ok ok ok ok
7.02 -> -> -> -> -> -> -> -> -> -> -> PBX -> PBX ok ok ok ok ok7.1x -> -> -> -> -> -> -> -> -> -> -> PBX -> -> PBX ok ok ok ok7.5x -> -> -> -> -> -> -> -> -> -> -> PBX -> -> -> PBX ok ok ok
7.61-7.67, n642 -> -> -> -> -> -> -> -> -> -> -> PBX -> -> -> -> PBX ok ok7.68, 7.71 -> -> -> -> -> -> -> -> -> -> -> PBX -> -> -> -> -> PBX ok
a) Office155 Air SW download, since PBX 5.50 "as130": Office160 can be announced as Office130 (with 15 digits)e) ATEX supported since Office155 1.13 and ATEX-Headset since 1.15 y) Office160 Air Sw Download works since PBX I7.0
z) since July 06 Sw 1.03 is delivered from fabrication.
-1/-1A -1A -1 -1
Office 160pro
Office 155 ATEX e)
Office155
Office 160 ATEX,Office 160 Safeguard
Office160 can replace Office155 also on I4 see CL992
HW-version -2: (fabrication ~ feb 2009)The display component had to be exchanged.HW -2 is supported with SW 1.16 1.16 is protected from downgrade
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 21
DECT-Systembases I5-I6-I7-compatibility-2009-01-19.xls
SW Download:"PBX" this DECT-SW is incl. in the PBX-SW"ok" this DECT-SW is unchanged (when registered on PBX)"->" newer DECT-SW is loaded (when registered on PBX, System "A")"<-" older DECT-SW is loaded (when registered on PBX, System "A")
"SW Category": protection from older SW"Lab.version": Internal version, twice Longklick 5
SB4
SW Category 0 0 0 1 1 1 2 2
Lab.version
00.42.00
01.05.00
01.06.00
01.07.00
01.11.00
01.12.00
01.14.02
01.15.00
DECT PBX
1.00 f) 1.05 1.06 1.07 h) 1.11 1.12 1.14.02 1.15
5.0x-5.30 00.57.6E (X) SB4 SB4 SB4 SB4 SB4 Xa) SB45.50-5.52 00.63.6E (X) SB4 SB4 SB4 SB4 SB4 Xa) SB4
5.55 00.64.6E (X) SB4 SB4 SB4 SB4 SB4 Xa) SB45.61-5.64 00.72.6E (X) SB4 SB4 SB4 SB4 SB4 Xa) SB46.00-6.11 00.72.6E (X) SB4 SB4 SB4 SB4 SB4 Xa) SB4
6.20 b) -6.23 00.75.6E (X) f) <- g) <- g) ok h) ok h) ok h) Xa) ok h) b) SB4+/SB8 SW download, since PBX 6.206.25-6.27 00.77.6E -> -> PBX ok ok ok Xa) ok
6.51 00.76.6E -> PBX <- ok ok ok ok ok f) SB-SW 1.00 is not recommended (was only used in FT)6.52-6.55 00.77.6E -> -> PBX ok ok ok ok ok g) upgrade PBX >= 6.25 to avoid SB-SW 1.006.60, 6.62 00.77.6E -> -> -> PBX <- <- ok ok h) protected 1.07 (in prod. since july 05)6.63 - 6.67 00.77.6E -> -> -> -> PBX <- ok ok -> no problem for Spain with PBX 6.21
7.02 00.77.6E -> -> -> -> -> PBX ok ok7.10, 7.11 00.77.6E -> -> -> -> -> PBX ok ok
7.16 00.77.6E -> -> -> -> -> -> PBX <-7.5x 00.77.6E -> -> -> -> -> PBX ok ok
7.61-7.66, n642 00.77.6E -> -> -> -> -> -> PBX <-7.67, 7.68, 7.71 00.77.6E -> -> -> -> -> -> -> PBX
SB4+ , SB8 b)
SB 1.14.02 is recommended for SB8
a) SB 1.14.02 contains a change that is not compatible with old PBX-Versions (RMS 36065).
It is rare, because the fabric. delivers 1.07. The problem is corrected with 1.15.
depl-0023 / CL 669 Note: Not all versions introduced in all Sales channels. Seite 22